Monitoring and Control Devices

Size: px
Start display at page:

Download "Monitoring and Control Devices"

Transcription

1 Siemens AG 200 Monitoring and Control Devices /2 Introduction SIMOCODE 3UF Motor Management and Control Devices /5 SIMOCODE pro 3UF motor management and control devices /12 SIMOCODE-DP 3UF5 motor protection and control devices /16 3UF18 current transformers for overload protection /1 3UL22 summation current transformers 3TK28 Safety Relays /69 General data /0 With electronic enabling circuits /2 With relay enabling circuits /5 With contactor relay enabling circuits Interface Converters / 3RS1 interface converters LOGO! Logic Modules /18 General data /19 LOGO! Modular basic variants /21 LOGO! Modular Pure variants /23 LOGO! Modular expansion modules /25 LOGO! CM EIB/KNX communications modules /26 AS-Interface connections for LOGO! Ch. 11 LOGO! Power /2 LOGO! Contact /28 LOGO! Software 3RP Timing Relays /29 3RP15 timing relays in industrial enclosure, 22.5 mm /35 3RP20 timing relays, 45 mm /39 3RT19 timing relays for mounting onto contactors Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements /42 Line monitoring /46 Voltage monitoring /48 Current monitoring /50 Power factor and active current monitoring /52 Insulation monitoring for ungrounded AC networks /53 Insulation monitoring for ungrounded DC networks /54 Level monitoring /56 Speed monitoring 3RS10, 3RS11 Temperature Monitoring Relays /5 Relays, analogically adjustable, for 1 sensor /60 Relays, digitally adjustable, acording to DIN 3440, for 1 sensor /63 Relays, digitally adjustable for up to 3 sensors 3RN1 Thermistor Motor Protection /65 For PTC sensors Siemens LV 1 200

2 Siemens AG 200 Monitoring and Control Devices Introduction Overview The advantages at a glance 3UF 3UF5 6ED1 052 Page SIMOCODE 3UF motor management and control devices SIMOCODE pro 3UF Compact, modular design 3UF /5 SIMOCODE-DP 3UF5 Unique flexibility in terms of functionality and hardware configuration Wide functional range from the distributed I/O system to 3UF5 /12 the autonomous motor management system All control functions from the direct-on-line starter to the pole-changing switch with reversing contactor All motor sizes Integration in all PROFIBUS-capable automation systems Application in low-voltage controlgear for motor control centers on the process industry Increases plant availability Saves costs during construction, commissioning and operation of the plant Extensive data of the motor feeder available everywhere on the PROFIBUS All protection, monitoring and control functions for the motor feeder in a single system 3UF18 current transformers Protection transformer for activating overload relays or 3UF18 /16 for overload protection for use with SIMOCODE 3UF Ensures proportional current transfer up to a multiple of the primary rated current 3UL22 summation current transformers Senses fault currents in machines and plants Senses earth-fault currents 3UL22 /1 LOGO! logic modules LOGO! logic modules LOGO! Modular basic variants LOGO! Modular Pure variants LOGO! Modular expansion modules LOGO! Modular communications modules LOGO! Power LOGO! Contact Compact, user-friendly and low-cost solution for simple control tasks Universal: - Building installation and wiring (lighting, shutters, awnings, doors, access control, barriers, ventilation systems...) - Control cabinet installation - Machine and device construction (pumps, small presses, compressors, hydraulic lifts, conveyors...) - Special controls for conservatories and greenhouses - Signal preprocessing for other controllers Flexible expansion depending on the application With display, pushbuttons and an interface for connecting expansion units Without display and pushbuttons but with an interface for connecting expansion units For connection to LOGO! Modular basic variants with digital inputs and outputs or analog inputs and outputs For integrating LOGO! in an instabus KNX EIB system or as an AS-Interface slave Power supply for converting the mains voltage of V AC into an operational voltage of 24 V DC or 12 V DC Switching module for switching resistive loads and motors directly 6ED /19 6ED /21 6ED /23 6BK1 00, /25, 3RK1 400 /26 6EP1 3 Ch. 11 6ED /2 LOGO! Software For switchgear program generation on the PC 6ED1 058 /28 /2 Siemens LV 1 200

3 Siemens AG 200 Monitoring and Control Devices Introduction The advantages at a glance 3RP 3UG UG RP timing relays 3RP15 timing relay in industrial enclosure, 22.5 mm Low-cost solution with monofunctions such as response delay, off-delay, clock-pulse, wye-delta function, multifunction Wide-range voltage designs Page 3RP15 /29 3RP20 timing relay, 45 mm The solution for small mounting depths 3RP20 /35 The low mounting height reduces the tier spacing 3RT19 timing relay for mounting onto contactors Saves space because the relay is mounted onto the 3RT19 /39 contactor Wiring advantages thanks to direct contacting to the contactor 3UG monitoring relays for electrical and additional measurements Line Monitoring Phase sequence Low-cost solution for monitoring the phase sequence 3UG45 11 /43 Phase sequence, phase failure, phase unbalance Wide voltage range from 160 to 690 V 3UG45 12 /43 Phase sequence, phase failure, phase unbalance and undervoltage Phase sequence, phase failure, phase unbalance, overvoltage and undervoltage Phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Automatic correction of the direction of rotation in case of wrong phase sequence, phase failure, phase unbalance, overvoltage and undervoltage Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Voltage Monitoring Voltage monitoring with internal power supply for overvoltage and undervoltage Voltage monitoring with auxiliary voltage for overvoltage and undervoltage Current Monitoring Current monitoring with auxiliary voltage for overshoot and undershoot Power factor and active current monitoring (motor load monitoring) Power factor and active current monitoring with internal power supply for overshoot, undershoot or window monitoring Insulation resistance Monitoring of the insulation resistance for ungrounded AC or DC networks from 1 to 110 kω Level Monitoring Fill level and resistance Analogically adjustable Wide voltage range from 160 to 690 V Digitally adjustable with LCD display for indication of ACTUAL value and device status Wide voltage range from 160 to 690 V Digitally adjustable with LCD display for indication of ACTUAL value and device status Wide voltage range from 160 to 690 V Digitally adjustable with LCD display for indication of ACTUAL value and device status Wide measuring ranges Variant for wide voltage range Digitally adjustable with LCD display for indication of ACTUAL value and device status Wide measuring ranges Variant for wide voltage range For monitoring over the entire torque range Digitally adjustable with LCD display for indication of ACTUAL value and device status Wide voltage range from 90 to 690 V 3UG45 13 /43 3UG46 14 /43 3UG46 15 /43 3UG46 16 /43 3UG46 1 /43 3UG46 18 /43 3UG46 33 /4 3UG46 31, 3UG UG46 21, 3UG46 22 Test button 3UG30 81, With or without storage 3UG30 82 Switchable measuring range As single-step or two-step controls for inlet or outlet monitoring of conducting liquids or as resistance threshold switch Adjustable, wide range from kω UNDER/OVER adjustable /4 /48 3UG46 41 /50 3UG35 01 /54 Speed Monitoring Underspeed monitoring Together with a sensor for monitoring continuous pulses 3UG30 51 /56 With or without storage Adjustable ON-delay 1, 2 and 3 changeover contacts Hard gold-plated contacts in combination and wide voltage range versions /52, /53 Siemens LV /3

4 Siemens AG 200 Monitoring and Control Devices Introduction The advantages at a glance Page 3RS10, 3RS11, 3RS20 temperature monitoring relays for monitoring the temperatures of solids, liquids, and gases Relays, analogically adjustable, for 1 sensor Separate versions for overshoot and undershoot 3RS10, /5 For simple monitoring tasks 3RS11 For PT100 or thermoelements J and K Adjustable hysteresis Relays, digitally adjustable, according to DIN 3440, For two-step or three-step controls 3RS10, /60 for 1 sensor For monitoring heat generation plants 3RS11,, For PT100/1000, KTY83/84, NTC or thermoelements 3RS20, type J, K, T, E, N, R, S, B 3RS21 Relay, digitally adjustable, for up to 3 sensors For simultaneously monitoring several sensors 3RS10 /63 Especially suited for monitoring motor winding temperatures For PT100/1000, KTY83/84, NTC 3RN1 thermistor motor protection For PTC sensors Relays for monitoring motor winding temperatures 3RN1 /65 with type A PTC sensors Integrated with ATEX approval Closed-circuit principle Depending on the version: With short-circuit and open-circuit detection, zero voltage safety, manual/auto/remote RESET, 1CO, 1NO+1NC, 2CO, 1NO+1CO or 2 CO hard gold-plating 3TK28 safety relays With electronic enabling circuits With relay enabling circuits With contactor relay enabling circuits 3RA1 load feeders with integrated safety technology 3RS1 interface converters Converters for standard signals and non-standard variables 3RS10 3RN1 Permanent function checking No wear because switched electronically High switching frequency Long electrical endurance Evaluation of solid-state sensors Sensor lead up to max m Cascading possible Insensitive to vibrations and dirt Compact design, low weight Approved for the world market Compact design Floating safe outputs Also suitable for press and punch controls Can be used up to an ambient temperature of max. 0 C 3TK28 3TK28 4 /0 3TK28 2, 3TK28 3 Enabling circuits, floating AC-15/DC-13 switching capacity Safe isolation Long mechanical and electrical endurance Certified as a complete unit Fault minimization and cost reduction through factory wiring Low installation costs 3TK28 5 /5 Available in fused or fuseless configuration 3RA1 Ch. 6 Enabling circuits, floating AC-1/AC-3 switching capacity Certified as a complete unit Long mechanical and electrical endurance Rated operational voltage up to 690 V Safe isolation All terminals protected against polarity reversing and overvoltage up to 30 V For electrical isolation and conversion of analog signals Short-circuit resistant outputs From 6.2 mm width Switchable multi-range converters Variants with manual/automatic switch for setpoint selection Variants for conversion of analog variables into frequency 3RS1 / /2 3RS1 /4 Siemens LV 1 200

5 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices Overview SIMOCODEpro basic unit, expansion module and operator panel SIMOCODE pro is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between I&C and motor feeder, increases plant availability and allows significant savings to be made for startup, operation and maintenance of a system. When SIMOCODE pro is installed in the low-voltage switchboard, it is the intelligent interface between the higherlevel automation system and the motor feeder and includes the following: Multifunctional, solid-state full motor protection which is independent of the automation system Flexible software instead of hardware for the motor control Detailed operational, service and diagnostics data Open communication through PROFIBUS DP, the standard for fieldbus systems SIMOCODE ES is the software package for SIMOCODE pro parameterization, start-up and diagnostics. Benefits General customer benefits Integrating the whole motor feeder into the process control by means of a bus significantly reduces the wiring outlay between the motor feeder and PLC Distribution of the automated processes by means of configurable control and monitoring functions in the feeder saves resources in the automation system and ensures full functionality and protection of the feeder even if the I&C or bus system fails The acquisition and monitoring of operational, service and diagnostics data in the feeder and process control system increases plant availability as well as maintenance and servicefriendliness The high degree of modularity allows users to perfectly implement their plant-specific requirements for each motor feeder The SIMOCODE pro system offers functionally graded and space-saving solutions for each customer application The replacement of the control circuit hardware with software decreases the number of hardware components and wiring required and in this way limits stock keeping costs and potential wiring errors The use of solid-state full motor protection permits better utilization of the motors and ensures long-term stability of the tripping characteristic and reliable tripping even after years of service Multifunctional, solid-state full motor protection for rated motor currents up to 820 A SIMOCODE pro offers comprehensive protection of the motor feeder by means of a combination of different, multi-step and delayable protection and monitoring functions: Inverse-time delayed solid-state overload protection (Class ) Thermistor motor protection Phase failure / unbalance protection Stall protection Monitoring of adjustable limit values for the motor current Voltage and power monitoring Monitoring of the power factor (motor idling/load shedding) Earth-fault monitoring Temperature monitoring, e.g. over PT100/PT1000 Monitoring of operating hours, downtime and number of starts etc. Recording of measuring curves SIMOCODE pro can record measuring curves and therefore is able, for example, to present the progression of motor current during motor start-up. Flexible motor control implemented with software (instead of comprehensive hardware interlocks) Many predefined motor control functions have already been integrated into SIMOCODE pro, including all necessary logic operations and interlocks: Direct-on-line and reversing starters Star/delta starters (also with direction reversal) Two speeds, motors with separate windings (pole-changing switch); also with direction reversal Two speeds, motors with separate Dahlander windings (also with direction reversal) Positioner actuation Solenoid valve actuation Activation of a circuit breaker Soft starter actuation (also with direction reversal) These control functions have been implemented in SIMOCODE pro by means of software and can be freely assigned to the inputs and outputs of the device (including PROFIBUS DP). These predefined control functions can also be flexibly adapted to each customized configuration of a motor feeder by means of freely configurable logic modules (truth tables, counters, timers, edge evaluation...) and with the help of standard functions (power failure monitoring, emergency start, external faults...), without additional auxiliary relays being necessary in the control circuit. SIMOCODE pro makes a lot of additional hardware and wiring in the control circuit unnecessary which results in a high level of standardization of the motor feeder in terms of its design and circuit diagrams. Siemens LV /5

6 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices Detailed operational, service and diagnostics data SIMOCODE pro makes different operational, service and diagnostics data available and helps to detect potential faults in time and to prevent them by means of preventative measures. In the event of a malfunction, a fault can be diagnosed, localized and rectified very quickly - there are no or very short downtimes. Operating data Motor switching state derived from the current flow in the main circuit All phase currents All line voltages Active power, apparent power and power factor Phase unbalance and phase sequence Time to trip Motor temperature Remaining cooling time etc. Service data Motor operating hours Motor stop times Number of motor starts Number of overload trips Internal comments stored in the device etc. Diagnostics data Numerous detailed early warning and fault messages Internal device fault logging with time stamp Time stamping of freely selectable status, alarm or fault messages etc. Communication SIMOCODE pro is equipped with an integral PROFIBUS DP interface (SUB-D or terminal connection) and can therefore replace all individual wiring (including modular terminals), which would usually be required for exchanging data with the higherlevel automation system, with a single 2-wire cable. SIMOCODE pro supports among other things: Baud rates up to 12 Mbit/s Automatic baud rate detection Communication with up to 3 masters Time synchronization over PROFIBUS Cyclic services (DPV0) and acyclic services (DPV1) DPV1 communication after the Y-Link etc. Main circuit Control circuit Automation level L1 L2 L3 -Q1 PROFIBUS DP -K1 -K2 SIMOCODE pro Operator panel Connection cable NSA0_00398 Current measuring module Basic unit -K1 -K2 0 Remote M 3~ Protect and monitor (overload, thermistor, earth fault detection...) Motor control (incl. monitoring + interlocking) Communication (operational, service, diagnostics data + control commands) SIMOCODE pro combines all the necessary functions for the motor feeder in a compact system. /6 Siemens LV 1 200

7 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices Application SIMOCODE pro is often used for automated processes where plant downtimes are very expensive (e.g. steel or cement industry) and where it is important to prevent plant downtimes through detailed operational, service and diagnostics data or to localize the fault very quickly in the event of a malfunction. SIMOCODE pro is modular and space-saving and suited especially for operation in motor control centers in the process industry and for power plant technology. Applications Protection and control of motors In hazardous areas for types of protection EEx e/d according to ATEX directive 94/9/EC With heavy starting (paper, cement, metal and water industries) In high-availability plants (chemical, oil, raw material processing industries, power plants) Industries Today, SIMOCODE pro is mainly used in the chemical (incl. oil and gas), steel, water, paper, pharmaceutical, cement, and glass industry. It is also used for applications in power plants and large diamond, gold and platinum mines. Based on the experience made with the predecessor system SIMOCODE-DP, SIMOCODE pro has been tailored even more specifically to the requirements of these industries. An essential requirement in these industries is the availability of the motors and thus the availability of the whole process. Plant downtimes caused by faults frequently result in high costs. For this reason, it is very important to detect potential faults early on and to initiate targeted countermeasures. SIMOCODE pro offers users an up-todate motor management system based on years of experience. Selection and ordering data SIMOCODE pro Version Current setting Width DT Screw terminals PU A mm SIMOCODE pro C, basic units 1 PROFIBUS DP interface, 12 Mbit/s, RS I/3 O freely assignable, input for thermistor connection, monostable relay outputs, rated control supply voltage U s : 24VDC A 3UF 000-1AB unit V AC/DC A 3UF 000-1AU unit UF 000-1A.00-0 SIMOCODE pro V, basic units 2 PROFIBUS DP interface, 12 Mbit/s, RS I/3 O freely assignable, input for thermistor connection, monostable relay outputs, can be expanded with expansion modules, rated control supply voltage U s : 24VDC A 3UF 010-1AB unit V AC/DC A 3UF 010-1AU unit UF 010-1A UF 100-1AA00-0 3UF 110-1AA00-0 Current measuring modules Straight-through transformers A 3UF 100-1AA unit A 3UF 101-1AA unit A 3UF 102-1AA unit A 3UF 103-1AA unit Busbar connection A 3UF 103-1BA unit A 3UF 104-1BA unit Current/voltage measuring modules 1) Voltage measuring up to 690 V Straight-through transformers C 3UF 110-1AA unit A 3UF 111-1AA unit A 3UF 112-1AA unit A 3UF 113-1AA unit Busbar connections A 3UF 113-1BA unit A 3UF 114-1BA unit Operator panels Installation in control cabinet door or front plate, for plugging into basic unit, 10 LEDs for status display and user-assignable buttons for manual control A 3UF 200-1AA unit UF 200-1AA00-0 See footnote page /8. Siemens LV /

8 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices Version Current setting Width DT Screw terminals PU A mm Expansion modules Note: Expansion modules can only be used in combination with basic unit 2! A total of up to 5 expansion modules can be connected in any order to one basic unit. Digital modules 4 binary inputs and 2 relay outputs, up to 2 digital modules can be connected A 3UF 3@0-1A@ unit per basic unit 2 3UF 300-1AU00-0 supplements Relay outputs monostable 0 bistable 1 Input voltage 24 V DC B V AC/DC U Analog modules 1) 2 inputs for input A 3UF 400-1AA unit and 1 output for output 0/ ma signals, up to 1 analog module can be connected per basic unit 2 3UF 400-1AA00-0 Earth-fault modules 1) 1 input for connecting a 3UL22 summation current transformer; up to 1 earth-fault module can be connected per basic unit 2 A 3UF 500-1AA unit UF 500-1AA00-0 Temperature modules 1) 3 inputs for connecting up to 3 analog temperature sensors, up to 1 temperature module can be connected per basic unit 2 A 3UF 00-1AA unit UF 00-1AA00-0 1) Only possible with basic unit 2, product version E02 and higher (from April 2005). /8 Siemens LV 1 200

9 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices Accessories Version DT PU Connection cables Connection cables in different lengths for connecting basic unit, current measuring module, current/voltage measuring module, operator panel or expansion modules: Length m (ribbon) Note: Only suitable for connecting basic unit 2 to its expansion modules or for connecting expansion modules to each other; only when the front plates finish at B 3UF 930-0AA unit UF 932-0AA00-0 the same height! Length 0.1 m (ribbon) B 3UF 931-0AA unit Length 0.3 m (ribbon) A 3UF 935-0AA unit Length 0.5 m (ribbon) B 3UF 932-0AA unit PC cables Length 0.5 m (round) A 3UF 932-0BA unit Length 1.0 m (round) A 3UF 93-0BA unit Length 2.5 m (round) A 3UF 933-0BA unit For PC/PG communication with SIMOCODE pro through the system interface, for connecting to the serial interface of the PC/PG B 3UF 940-0AA unit UF 940-0AA00-0 Memory modules For parameterizing SIMOCODE pro without using apc/pg through the system interface A 3UF 900-0AA unit UF 900-0AA00-0 Interface covers For system interface A 3UF 950-0AA units Addressing plugs For assigning the PROFIBUS addresses without using a PC/PG on a basic unit through the system interface B 3UF 910-0AA unit UF 910-0AA00-0 Door adapters For external connection of the system interface outside, for example, a control cabinet A 3UF 920-0AA unit UF 920-0AA00-0 Push-in lugs 3RB B Terminal covers 3RT EA1 3RT EA2 For screw fixing e.g. on mounting plate, 2 units required per device can be used with 3UF 1.0, 3UF 1.1 and 3UF 1.2 C 3RB B units can be used with 3UF 0, 3UF 3, 3UF 4, 3UF 5 and 3UF } 3RP units Covers for cable lugs and rail connections Length 100 mm, can be used for 3UF 1.3-1BA00-0 } 3RT EA1 1 1 unit Length 120 mm, can be used for 3UF 1.4-1BA00-0 } 3RT EA1 1 1 unit Covers for box terminals Length 25 mm, can be used for 3UF 1.3-1BA00-0 } 3RT EA2 1 1 unit Length 30 mm, can be used for 3UF 1.4-1BA00-0 } 3RT EA2 1 1 unit Covers for screw terminals between contactor and current measuring module or current/voltage measuring module for direct mounting Can be used for 3UF 1.3-1BA00-0 } 3RT EA3 1 1 unit Can be used for 3UF 1.4-1BA00-0 } 3RT EA3 1 1 unit Siemens LV /9

10 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices Version DT PU Box terminal blocks For round and ribbon cables up to 0 mm 2, can be used for 3UF 1.3-1BA00-0 } 3RT G 1 1 unit up to 120 mm 2, can be used for 3UF 1.3-1BA00-0 } 3RT G 1 1 unit up to 240 mm 2, can be used for 3UF 1.4-1BA00-0 } 3RT G 1 1 unit for conductor cross-sections, see LV 1 T "Technical Information" 3RT G System manuals SIMOCODE pro with token fee, languages: German B 3UF 90-0AA unit English B 3UF 90-0AA unit French B 3UF 90-0AA unit UF 90-0AA01-0 PCS function block library for SIMOCODE pro For integrating SIMOCODE pro into the PCS process control system PCS function block library for SIMOCODE pro, V6.0 Scope of supply: AS modules and faceplates for integrating SIMOCODE pro into the PCS process control system, for PCS Version V6.0 Engineering software for one engineering station (single license) including runtime software for 3UF 982-0AA00-0 execution of the AS module in an automation system (single license), English/German Type of delivery: CD incl. documentations PCS function block library for SIMOCODE pro, V6.1 Scope of supply: AS modules and faceplates for integrating SIMOCODE pro into the PCS process control system, for PCS Version V6.1 Engineering software for one engineering station (single license) including runtime software for execution of the AS module in an automation system (single license), English/German Type of delivery: CD incl. documentation AS modules for integrating SIMOCODE pro into the PCS process control system, for PCS Version V6.x Runtime software for execution of the AS module in an automation system (single license), license without software and documentation SIMOCODE ES Parameterization and service software for SIMOCODE pro Executes on PC/PG under Windows 2000/XP, without PC cable Type of delivery: CD, single license Variants: 3ZS CC10-0YA0 SIMOCODE ES Smart, for parameterizing through the system interface on the device SIMOCODE ES Professional, for parameterizing through PROFIBUS or the system interface on the device, incl. STEP object manager SIMOCODE ES Graphic, optional expansion of SIMOCODE ES Smart/ Professional with a graphical editor for ergonomic and user-friendly parameterization by means of Drag & Drop Requirements (minimum): Installed SIMOCODE ES Smart 2004 with SP1 or installed SIMOCODE ES Professional 2004 with SP1 A 3UF 982-0AA unit A 3UF 982-0AA unit A 3UF 982-0AA unit B 3ZS CC10-0YA0 1 1 unit B 3ZS CC10-0YA0 1 1 unit A 3ZS CC10-0YA0 1 1 unit /10 Siemens LV 1 200

11 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE pro 3UF motor management and control devices More information Important ordering notes SIMOCODE pro is a modularly constructed motor management system which is subdivided into two device series with different functional scopes: SIMOCODE pro C, as a compact system for direct-on-line starters and reversing starters SIMOCODE pro V, as a variable system with all control functions and with the possibility of expanding the inputs, outputs and functions of the system at will using expansion modules. System manual For selection of equipment and for configuration, it is recommended that the 3UF 90-0AA0.-0 system manual is consulted. Internet You can find further information on the Internet at: Expansion possibilities SIMOCODE pro C, Basic Unit 1 Available -- Not available SIMOCODE pro V, Basic Unit 2 Operator panels Current measuring modules Current/voltage measuring -- modules Expansion modules: Digital modules (max. 2) Analog module (max. 1) Earth-fault module (max. 1) Temperature module (max. 1) Protection, control and monitoring functions as well as the data and measured values deliverable by each system are directly dependent on the device configuration selected and on the expansion modules used. A detailed description of the functionality of all SIMOCODE pro system components can be found in the system manual or LV 1 T "Technical Information". Siemens LV /11

12 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE-DP 3UF5 motor protection and control devices Overview SIMOCODE-DP is the predecessor of the SIMOCODE pro motor management system and offers the solution for a wide range of different tasks in a single unit: Multifunctional, electronic motor protection and plant monitoring Comprehensive motor and plant diagnostics Integrated control programs (instead of extensive hardware wiring) Open communication through PROFIBUS DP, the standard for fieldbus systems SIMOCODE-DP basic unit, expansion module and operator module /12 Siemens LV 1 200

13 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices Selection and ordering data SIMOCODE-DP 3UF5 motor protection and control devices Basic units 3UF5 001 to 021 Version DT Screw terminals PU 4 inputs, 4 outputs for snap-on mounting onto 35 mm standard mounting rail Contactors that can Width be mounted externally Setting range Type mm A ) C 3UF @@@ unit C 3UF @@@ unit C 3UF @@@ unit RT C 3UF @@@ unit RT10 6, 3RT C 3UF @@@ unit RT12 6, 3RT12 3TF68, 3TF C 3UF @@@ unit UF5 031 to 051 supplements Inputs Input for thermistor motor protection A -- Add. price 2) Earth-fault detection input (external) B (sensing of earth-fault currents of sizes 0.3 A, A and 1 A with 3UL2 20.-A. summation current transformers) Rated control voltage 24 V DC B x 115 V AC J V AC N -- Behavior of the outputs in case of control supply voltage failure monostable 0 -- bistable 1 x x = with additional price -- = without additional price 1) The current setting range of A is obtained by multiple looping of the main circuits through the current transformers of the basic unit. Expansion modules 2) Totals are rounded up and down. This may lead to slight differences in the overall price. Version DT Screw terminals PU 8 inputs, 4 outputs for snap-on mounting onto 35 mm standard mounting rail External supply voltage for the inputs 24 V DC A 3UF AB unit V AC A 3UF AJ unit V AC A 3UF AN unit UF A.00 Operator panels For installation in the control cabinet door for plugging into basic unit or expansion module A 3UF AA unit UF AA00-1 Siemens LV /13

14 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE-DP 3UF5 motor protection and control devices Accessories Version DT PU Configuration software Win-SIMOCODE-DP/Professional Parameterization, control, visualization and testing of SIMOCODE-DP: through PROFIBUS or the system interface on the device PC/PG requirement: Windows 95/98/2000/NT/ME or Windows XP A 3UF5 10-0AA unit UF5 10-0AA00-0 PC/PG interface requirement: PROFIBUS system interface from Siemens or RS 232 with compatible 3RW DA00 interface cable SIMOCODE-DP requirement: Delivery stage E10 (as of June 1998) Type of delivery: CD-ROM, English/German incl. online Help and example parameter files, single license Win-SIMOCODE-DP/Smart Parameterization, control, visualization and testing: through the interface on the device PC/PG requirement: Windows 95/98/2000/NT/ME or Windows XP A 3UF5 11-0AA unit UF5 11-0AA00-0 PC/PG interface requirement: RS 232 with compatible 3RW DA00 interface cable Type of delivery: CD-ROM, English/German incl. online Help and example parameter files, single license OM-SIMOCODE-DP A 3UF5 12-0AA unit STEP Object Manager for integrating SIMOCODE-DP as S slave and for call of Win-SIMOCODE-DP/Professional from STEP Requirements: STEP, Version 4.0 or higher SIMOCODE-DP requirement: Delivery stage E10 (as of June 1998) Type of delivery: CD-ROM, English/German incl. online Help, single license PCS SIMOCODE-DP function blocks Function block for integrating SIMOCODE-DP into the process control system, PCS, Version V6.0 SIMOCODE-DP requirement: Delivery stage E10 and higher (as of June 1998) Type of delivery: CD-ROM, English/German, single license A 3UF5 20-0AA unit Documentation System manuals with description of the communication through PROFIBUS DP and a configuration example German A 3UF5 00-0AA unit English A 3UF5 00-0AA unit /14 Siemens LV 1 200

15 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices SIMOCODE-DP 3UF5 motor protection and control devices Version DT Connection cables, installation materials Connection cables for PC communication through the system interface on the device Length 5 m Plug-in connectors/connecting cables with 3UF5 9/3UF1 9 connectors For connecting the basic unit to the expansion module, 9-pole, 0.03 m, flat connector shielded 3UF MA00 3UF NA00 3UF PA00 3UF DA00 3UF EA00 Push-in lugs PU A 3RW DA unit A 3UF AA unit For connecting the basic unit to the expansion module or to the operator panel, 9-pole m long, shielded connector, 45 angled B 3UF MA unit m long, shielded connector, 45 angled B 3UF NA unit m long, shielded connector, 45 angled B 3UF PA unit m long, with flat connector, shielded A 3UF DA unit m long, with flat connector, shielded A 3UF EA unit For connecting basic unit/expansion module to the control cabinet door It is possible to set parameters, operate and monitor using the PC from the control cabinet door, 9-pole m long, with flat connector and socket, A 3UF AA unit shielded m long, with flat connector and socket, A 3UF BA unit shielded T-shaped terminals Terminal for bus connection to A 3UF GA unit PROFIBUS DP - RS 485 3UF1 900 bus terminations Bus termination module with separate supply voltage for terminating the bus following the last unit on the bus line. Supply voltage: 115/230 V AC A 3UF KA unit V DC A 3UF KB unit For screw mounting on mounting plate 2 units are required for each 3UF5 0 C 3RB B units RB B Terminal covers For stand-alone installation or on the output side for direct mounting - 3UF5 031 D 3TX 506-0A 1 1 unit UF5 041 D 3TX 536-0A 1 2 units UF5 051 with 3TF68 B 3TX 686-0A 1 1 set UF5 051 with 3TF69 B 3TX 696-0A 1 1 set TX 506-0A 3TX 506-0B Between contactor and overload relay for direct mounting - 3UF5 031 D 3TX 506-0B 1 1 unit UF5 041 D 3TX 536-0B 1 1 unit UF5 051 with 3TF68 C 3TX 686-0B 1 1 unit UF5 051 with 3TF69 C 3TX 696-0B 1 2 units More information System manual For selection of equipment and for configuration, it is recommended that the 3UF5 system manual is consulted. Internet More information can be found on the Internet under Siemens LV /15

16 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices 3UF18 current transformers for overload protection Overview The 3UF18 current transformers are protection transformers and are used for actuating overload relays. Protection transformers are designed to ensure proportional current transfer up to a multiple of the primary rated current. The 3UF18 current transformers convert the maximum current of the corresponding operating range into the standard signal 1 A secondary. Selection and ordering data Mounting type For stand-alone installation Screw mounting and snap-on mounting onto 35 mm standard mounting rail Operating range A DT Screw terminals PU ) C 3UF BA unit ) C 3UF AA unit ) C 3UF BA unit C 3UF CA unit C 3UF18 4-2DA unit C 3UF EA unit UF18 43 For mounting onto contactors and stand-alone installation Screw mounting C 3UF AA unit C 3UF BA unit C 3UF CA unit C 3UF DA unit C 3UF18 5-3EA unit C 3UF FA unit C 3UF GA unit UF ) The following setting ranges for the protection of EEx e motors are applicable: 3UF BA00, 0.25 A A 3UF AA00, 1.25 A A 3UF BA00, 2.5 A A Accessories Terminal covers 3TX 466-0A For contactor type DT PU For transformer/contactor combinations and stand-alone installation for transformer (cover required per connection side) 3UF18 45 D 3TX 446-0A 1 1 unit UF18 48 D 3TX 466-0A 1 1 unit UF18 50, 3UF18 52 D 3TX 506-0A 1 1 unit UF18 54 to 3UF18 5 D 3TX 536-0A 1 2 units UF FA00 B 3TX 686-0A 1 1 set UF GA00 B 3TX 696-0A 1 1 set For covering the screw terminal for direct mounting on contactor (cover required per contactor/ transformer combination) 3UF18 48 D 3TX 466-0B 1 1 unit UF18 50, 3UF18 52 D 3TX 506-0B 1 1 unit UF18 54 to 3UF18 5 D 3TX 536-0B 1 1 unit UF FA00 C 3TX 686-0B 1 1 unit UF GA00 C 3TX 696-0B 1 2 units /16 Siemens LV 1 200

17 Siemens AG 200 SIMOCODE 3UF Motor Management and Control Devices 3UL22 summation current transformer Overview Application The 3UL22 summation current transformers sense fault currents The residual-current operated circuit breaker circuit is designed in machines and plants. Together with the 3UL21 evaluation unit to prevent an excessively high touch voltage remaining in existence on a conductive part of the plant not belonging to the op- or the SIMOCODE 3UF motor management and control device they enable residual-current and earth-fault monitoring. erating circuit. A residual current which exceeds a certain value will disconnect all poles of the incoming leads, including any neutral conductor that may be present, within 0.2 s. Selection and ordering data Feed-through opening diameter Rated fault current DT Screw terminals PU I n mm A Summation current transformers for external earth-fault monitoring B 3UL A 1 1 unit C 3UL A 1 1 unit B 3UL A 1 1 unit B 3UL A 1 1 unit B 3UL A 1 1 unit B 3UL A 1 1 unit B 3UL B 1 1 unit B 3UL B 1 1 unit B 3UL B 1 1 unit UL A 40 B 3UL B 1 1 unit B 3UL A 1 1 unit B 3UL A 1 1 unit B 3UL A 1 1 unit B 3UL B 1 1 unit B 3UL B 1 1 unit Siemens LV /1

18 LOGO! Logic Modules Siemens AG 200 General data Overview The compact, user-friendly, and low-cost solution for simple control tasks Compact, user-friendly, can be used universally without accessories All in one: the display and operator panel are integrated 36 different functions can be linked at a press of a button or with PC software; up to 130 times in total Functions can be changed simply using buttons; no complicated rewiring Application The LOGO! logic module is the user-friendly, low-cost solution for simple control tasks. LOGO! is universally applicable, e.g.: Building installation and wiring (lighting, shutters, awnings, doors, access control, barriers, ventilation systems...) Control cabinet installation Machine and device construction (pumps, small presses, compressors, hydraulic lifts, conveyors...) Special controls for conservatories and greenhouses Signal preprocessing for other controllers The LOGO! Modular logic modules can be expanded easily for each application. Marine approvals American Bureau of Shipping, Bureau Veritas, Det Norske Veritas, Germanischer Lloyd, Lloyds Register of Shipping; Polski Rejestr Statków Catalog ST 0: Information on LOGO! can also be found in the catalog ST 0: catalog/en/st0k1ae.pdf /18 Siemens LV 1 200

19 Siemens AG 200 LOGO! Logic Modules LOGO! Modular basic variants Overview The space-saving basic variants Interface for connecting expansion modules, max. 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed Selection and ordering data Version DT Screw terminals PU LOGO! logic modules 24 A 6ED CC00-0BA5 1 1 unit Supply voltage 24 V DC, 8 digital inputs 24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A; 130 function blocks can be combined, modular expandability LOGO! 12/24RC logic modules A 6ED MD00-0BA5 1 1 unit Supply voltage 12/24 V DC, 8 digital inputs 12/24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 relay outputs 10 A, integrated time switch; 130 function blocks can be combined, modular expandability LOGO! 24RC logic modules A 6ED HB00-0BA5 1 1 unit Supply voltage 24 V AC/DC, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, integrated time switch; 130 function blocks can be combined, modular expandability LOGO! 230RC logic modules A 6ED FB00-0BA5 1 1 unit Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, integrated time switch; 130 function blocks can be combined, modular expandability Siemens LV /19

20 LOGO! Logic Modules Siemens AG 200 LOGO! Modular basic variants Accessories Version DT PU LOGO! Manuals German A 6ED AA00-0AE6 1 1 unit English A 6ED AA00-0BE6 1 1 unit French B 6ED AA00-0CE6 1 1 unit Spanish B 6ED AA00-0DE6 1 1 unit Italian B 6ED AA00-0EE6 1 1 unit LOGO! Memory Cards A 6ED CA00-0BA0 1 1 unit for copying, with know-how protection LOGO! Soft Comfort V5.0 A 6ED BA01-0YA0 1 1 unit for programming on the PC in LAD/FBD; runs on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO! Soft Comfort Upgrade A 6ED CA01-0YE0 1 1 unit from V1.0 to V5.0 LOGO! PC cables A 6ED1 05-1AA00-0BA0 1 1 unit for transferring programs between LOGO! and PC Front panel assembly kits Width: 4 MW C 6AG1 05-1AA00-0AA0 1 1 unit Width: 8 MW C 6AG1 05-1AA00-0AA1 1 1 unit Width: 8 MW, with pushbuttons C 6AG1 05-1AA00-0AA2 1 1 unit LOGO! News Box, 12/24 V contains LOGO! 12/24RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material German A 6ED1 05-3BA00-0AA4 1 1 unit 2Z English A 6ED1 05-3BA00-0BA4 1 1 unit 2Z LOGO! News Box, 230 V contains LOGO! 230RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material German A 6ED1 05-3AA01-0AA0 1 1 unit 2Z English A 6ED1 05-3AA01-0BA0 1 1 unit 2Z /20 Siemens LV 1 200

21 Siemens AG 200 LOGO! Logic Modules LOGO! Modular pure variants Overview The cost-optimized basic variants Interface for connecting expansion modules, max. 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs can be addressed Selection and ordering data Version DT Screw terminals PU LOGO! logic modules 24o A 6ED CC00-0BA5 1 1 unit Supply voltage 24 V DC, 8 digital inputs 24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A; without display and keyboard; 130 function blocks can be combined, modular expandability LOGO! 12/24RCo logic modules A 6ED MD00-0BA5 1 1 unit Supply voltage 12/24 V DC, 8 digital inputs 12/24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 relay outputs 10 A, integrated time switch; without display and keyboard; 130 function blocks can be combined, modular expandability LOGO! 24RCo logic modules A 6ED HB00-0BA5 1 1 unit Supply voltage 24 V AC/DC, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, integrated time switch; without display and keyboard; 130 function blocks can be combined, modular expandability LOGO! 230RCo logic modules A 6ED FB00-0BA5 1 1 unit Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, integrated time switch; without display and keyboard; 130 function blocks can be combined, modular expandability Siemens LV /21

22 LOGO! Logic Modules Siemens AG 200 LOGO! Modular pure variants Accessories Version DT PU LOGO! Manuals German A 6ED AA00-0AE6 1 1 unit English A 6ED AA00-0BE6 1 1 unit French B 6ED AA00-0CE6 1 1 unit Spanish B 6ED AA00-0DE6 1 1 unit Italian B 6ED AA00-0EE6 1 1 unit LOGO! Memory Cards A 6ED CA00-0BA0 1 1 unit for copying, with know-how protection LOGO! Soft Comfort V5.0 A 6ED BA01-0YA0 1 1 unit for programming on the PC in LAD/FBD; runs on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO! Soft Comfort Upgrade A 6ED CA01-0YE0 1 1 unit from V1.0 to V5.0 LOGO! PC cables A 6ED1 05-1AA00-0BA0 1 1 unit for transferring programs between LOGO! and PC /22 Siemens LV 1 200

23 Siemens AG 200 LOGO! Logic Modules LOGO! Modular expansion modules Overview Expansion modules for connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs Selection and ordering data Version DT Screw terminals PU LOGO! DM8 24 A 6ED CB00-0BA0 1 1 unit Supply voltage 24 V DC, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 0.3 A LOGO! DM16 24 A 6ED CB10-0BA0 1 1 unit Supply voltage 24 V DC, 8 digital inputs 24 V DC, 8 digital outputs 24 V DC, 0.3 A LOGO! DM8 12/24R A 6ED MB00-0BA1 1 1 unit Supply voltage 12/24 V DC, 4 digital inputs 12/24 V DC, 4 relay outputs 5 A LOGO! DM8 24R A 6ED HB00-0BA0 1 1 unit Supply voltage 24 V AC/DC, 4 digital inputs 24 V AC/DC, 4 relay outputs 5 A LOGO! DM16 24R A 6ED NB10-0BA0 1 1 unit Supply voltage 24 V DC, 8 digital inputs 24 V DC, 8 relay outputs 5 A LOGO! DM8 230R A 6ED FB00-0BA1 1 1 unit Supply voltage 115/230 V AC/DC, 4 digital inputs 115/230 V AC/DC, 4 relay outputs 5 A LOGO! DM16 230R A 6ED FB10-0BA0 1 1 unit Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 8 relay outputs 5 A LOGO! AM2 A 6ED MA00-0BA0 1 1 unit Supply voltage 12/24 V DC, 2 analog inputs V or ma, 10 bit resolution LOGO! AM2 PT 100 A 6ED MD00-0BA0 1 1 unit Supply voltage 12/24 V DC, 2 analog inputs for Pt100, temperature range -50 C to 200 C LOGO! AM2 AQ A 6ED MM00-0BA0 1 1 unit Supply voltage 24 V DC, 2 analog outputs 0 to 10 V Siemens LV /23

24 LOGO! Logic Modules Siemens AG 200 LOGO! Modular expansion modules Accessories Version DT PU LOGO! Manuals German A 6ED AA00-0AE6 1 1 unit English A 6ED AA00-0BE6 1 1 unit French B 6ED AA00-0CE6 1 1 unit Spanish B 6ED AA00-0DE6 1 1 unit Italian B 6ED AA00-0EE6 1 1 unit LOGO! Memory Cards A 6ED CA00-0BA0 1 1 unit for copying, with know-how protection LOGO! Soft Comfort V5.0 A 6ED BA01-0YA0 1 1 unit for programming on the PC in LAD/FBD; executes under Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO! Soft Comfort Upgrade A 6ED CA01-0YE0 1 1 unit from V1.0 to V5.0 LOGO! PC cables A 6ED1 05-1AA00-0BA0 1 1 unit for transferring programs between LOGO! and PC LOGO! News Box, 12/24 V contains LOGO! 12/24RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material German A 6ED1 05-3BA00-0AA4 1 1 unit 2Z English A 6ED1 05-3BA00-0BA4 1 1 unit 2Z LOGO! News Box, 230 V contains LOGO! 230RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material German A 6ED1 05-3AA01-0AA0 1 1 unit 2Z English A 6ED1 05-3AA01-0BA0 1 1 unit 2Z /24 Siemens LV 1 200

25 Siemens AG 200 LOGO! Logic Modules LOGO! CM EIB/KNX communications modules Overview Expansion module for the LOGO! basic variants For communication between the LOGO! master and external EIB components via EIB. Application The CM EIB/KNX communications module allows communication between the LOGO! master and external EIB components via EIB. The module can be used to integrate LOGO! into an EIB system. Selection and ordering data Version DT Screw terminals PU LOGO! CM EIB KNX communications modules B 6BK1 00-0BA00-0AA1 1 1 unit for connection to EIB, supply voltage 24 V DC Accessories Version DT PU LOGO! Manuals German A 6ED AA00-0AE6 1 1 unit English A 6ED AA00-0BE6 1 1 unit French B 6ED AA00-0CE6 1 1 unit Spanish B 6ED AA00-0DE6 1 1 unit Italian B 6ED AA00-0EE6 1 1 unit Siemens LV /25

26 LOGO! Logic Modules Siemens AG 200 AS-Interface connections for LOGO! Overview Every LOGO! can now be connected to the AS-Interface system Using the AS-Interface connection for LOGO!, an intelligent slave can be integrated in the AS-Interface system. With the modular interface it becomes possible to integrate the different basic units in the system according to their functionality. Similarly, functionalities can be quickly and easily adapted to new requirements by exchanging the basic unit. The interface module provides four inputs and four outputs on the system. These I/Os do not actually exist in hardware terms, however, but are only virtually present through the interface on the bus. Selection and ordering data Version DT Screw terminals PU AS-Interface connections for LOGO! A 3RK CE10-0AA2 1 1 unit virtual inputs, 4 virtual outputs /26 Siemens LV 1 200

27 Siemens AG 200 LOGO! Logic Modules LOGO! Contact Overview Switching module for switching resistive loads and motors directly Application LOGO! Contact is a switching module for direct switching of resistive loads up (to 20 A) and motors (up to 4 kw). LOGO! Contact operates hum-free without noise pollution. Selection and ordering data LOGO! Contact is universally applicable: Buildings/electrical installations Industry and commerce Version DT Screw terminals PU LOGO! Contact Switching module for direct switching of resistive loads up to 20 A and motors up to 4 kw Switching voltage 24 V A 6ED1 05-4CA00-0AA0 1 1 unit Switching voltage 230 V A 6ED1 05-4EA00-0AA0 1 1 unit Siemens LV /2

28 LOGO! Logic Modules Siemens AG 200 LOGO! Software Overview The user-friendly software for switchgear program generation on the PC Switchgear program generation for function diagrams (FBD) or contact diagrams (LAD) Additional testing, simulation, online testing and archiving of the switching programs Professional documentation with the help of various comment and print functions Application LOGO! Soft Comfort is the multilingual software for switchgear program generation with LOGO! on the PC. LOGO! Soft Comfort can be used to program all devices of the LOGO! family. Selection and ordering data Version DT PU LOGO! Soft Comfort V5.0 A 6ED BA01-0YA0 1 1 unit for programming on the PC in LAD/FBD; runs on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO! Soft Comfort Upgrade A 6ED CA01-0YE0 1 1 unit from V1.0 to V5.0 /28 Siemens LV 1 200

29 Siemens AG 200 3RP Timing Relays Overview LED for indicating "Timing relay on voltage" LED for indicating "Relay switched" Time setting range selector switch Function switch Device labeling plate Operating time adjustment Inspection window for set time range Inspection window for set function 3RP15 timing relays in industrial enclosure, 22.5 mm Application Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings. Enclosure version All timing relays are suitable for snap-on mounting onto TH 35 standard mounting rails according to EN 6015 or for screw fixing. Standards The timing relays comply with: EN "Environmental conditions" EN /DIN VDE 0435 Part 2021 "Electrical relays, timing relays" EN and EN "Electromagnetic compatibility" EN ; (VDE 0660 Part 200) "Low-voltage switchgear and controlgear" Accessories Push-in lugs for screw mounting Sealable cover Label set for marking the multifunction relay Siemens LV /29

30 3RP Timing Relays Siemens AG 200 3RP15 timing relays in industrial enclosure, 22.5 mm Selection and ordering data Solid-state timing relays for general use in control systems and mechanical engineering with: 1 changeover contact or 2 changeover contacts Single or selectable time setting ranges Switch position indication by LED Voltage indication by LED Version Time setting range t adjustable by rotary switch to Rated control supply voltage U s DT Screw terminals PU AC 50/60 Hz DC V V 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Insert labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. 1) with LED and 1 CO contact, s 8 functions s s s 2 CO contacts, min 16 functions s min 3RP B min min 2 CO contacts, h positively driven min and hard goldplated h h 8 functions 4)5) h h 2) 3RP15 1. timing relays, ON-delay, 1 time setting range with LED and 1 CO contact A 3RP AA unit / } 3RP AQ unit / } 3RP AP unit ) ) } 3RP AW unit / } 3RP BQ unit / } 3RP BP unit ) ) } 3RP BW unit A 3RP BT unit } 3RP RW unit s 24/ } 3RP AQ unit / } 3RP AP unit s 24/ } 3RP AQ unit / } 3RP AP unit s 24/ } 3RP AQ unit / } 3RP AP unit RP A... 3RP15 25 timing relays, ON-delay, 15 time setting ranges with LED and 3RP A... 1 CO contact s s s s min s min min min h min h h h h 2) 2 CO contacts / / 3RP15 2 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO contact (semiconductor) s s s s 24/ } 3RP AQ unit / } 3RP AP unit ) A 3RP BR unit / } 3RP BQ unit / ) 24 } 3RP BP unit ) } 3RP BW unit ) A 3RP15 2-1EC unit ) } 3RP15 2-1EM unit RP15 2-1E... 1) For functions, see 3RP label set. 2) With switch position, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0. to 1.1 x U s. 4) Positively driven: NO and NC are never closed simultaneously; contact gap 0.5 mm is ensured, minimum make-break capacity 12 V, 3 ma. /30 Siemens LV ) The changeover contacts are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous contact). 6) Operating range 0.8 to 1.1 x U s.

31 Siemens AG 200 3RP Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Solid-state timing relays for general use in control systems and mechanical engineering with: 1 changeover contact or 2 changeover contacts Single or selectable time setting ranges Switch position indication by LED Voltage indication by LED Version Time setting range t adjustable by rotary switch to Rated control supply voltage U s DT Spring-loaded terminals PU AC 50/60 Hz DC V V 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Insert labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. 1) with LED and 1 CO contact, s 8 functions s s 2 CO contacts, s 16 functions min s min 2 CO contacts, min positively driven min and hard goldplated min h 8 functions 4)5) h h h h 2) 3RP15 1. timing relays, ON-delay, 1 time setting range with LED and 1 CO contact 24/ C 3RP AQ unit / A 3RP AP unit ) ) A 3RP AW unit / A 3RP BQ unit / A 3RP BP unit ) ) A 3RP BW unit A 3RP RW unit s 24/ C 3RP AQ unit / A 3RP AP unit s 24/ C 3RP AQ unit / A 3RP AP unit C 3RP AQ s 24/ unit / C 3RP AP unit RP15 25 timing relays, ON-delay, 15 time setting ranges with LED and 1 CO contact s s s s min s min min min h min h h h h 2) 24/ C 3RP AQ unit / A 3RP AP unit CO contacts 24/ C 3RP BQ unit / A 3RP BP unit ) ) A 3RP BW unit RP15 2 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO contact s ) C 3RP15 2-2EC unit (semiconductor) s ) C 3RP15 2-2EM unit s s 1) For functions, see 3RP label set. 2) With switch position, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0. to 1.1 x U s. 4) Positively driven: NO and NC are never closed simultaneously; contact gap 0.5 mm is ensured, minimum make-break capacity 12 V, 3 ma. 5) The changeover contacts are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous contact). 6) Operating range 0.8 to 1.1 x U s. Siemens LV /31

32 3RP Timing Relays Siemens AG 200 3RP15 timing relays in industrial enclosure, 22.5 mm Solid-state timing relays for general use in control systems and mechanical engineering with 1 changeover contact or 2 changeover contacts Single or selectable time setting ranges Switch position indication by LED Voltage indication by LED Version Time setting range t adjustable by rotary switch to Rated control supply voltage U s DT Screw terminals PU AC 50/60 Hz DC V V 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range with LED and 1 CO contact The same potential must be applied to terminals A and B s 24/ A 3RP AQ unit / } 3RP AP unit s 24/ A 3RP AQ unit / } 3RP AP unit s 24/ A 3RP AQ unit / } 3RP AP unit RP A... 3RP15 40 timing relays, OFF-delay, without auxiliary voltage, time setting ranges 1) with LED and 1 CO contact s s s s s s s ) } 3RP AB unit ) } 3RP AJ unit ) } 3RP AN unit CO contacts ) } 3RP BB unit ) A 3RP BJ unit ) } 3RP BN unit RP A... 3RP15 55 timing relays, clock-pulse relay, 15 time setting ranges with LED and s / / 1 CO contact s 60 5) A 3RP AR unit s 24/ } 3RP AQ unit s 24/ } 3RP AP unit min s min min 3RP A min h min h h h h 4) 3RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range 3 NO contacts 3) (common contact root terminal 1) wye-delta s, overtravel time (idling) s 24/ A 3RP SQ unit / } 3RP SP unit RP S... 3RP15. timing relays, wye-delta function 6), dead interval 50 ms, 1 time setting range 1 NO contact s 24/ } 3RP15 4-1NQ unit instantaneous and 24/ } 3RP15 4-1NP unit NO contact / -- B 3RP15 4-1NM unit delayed (common contact s 24/ } 3RP15 6-1NQ unit root terminal 1) 24/ } 3RP15 6-1NP unit / -- B 3RP15 6-1NM unit RP15.-1N... 1) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. 2) Operating range 0. to 1.25 x U s. 3) Operating range 0.85 to 1.1 x U s. 4) With switch position, no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x U s. 6) For example circuit, see LV 1 T "Technical Information", Circuit Diagrams. /32 Siemens LV 1 200

33 Siemens AG 200 3RP Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Solid-state timing relays for general use in control systems and mechanical engineering with 1 changeover contact or 2 changeover contacts Single or selectable time setting ranges Switch position indication by LED Voltage indication by LED Version Time setting range t adjustable by rotary switch to 1) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. 2) Operating range 0. to 1.25 x U s. 3) Operating range 0.85 to 1.1 x U s. 4) With switch position, no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x U s. 6) For example circuit, see LV 1 T "Technical Information", Circuit Diagrams. Rated control supply DT Spring-loaded terminals PU voltage U s AC 50/60 Hz DC V V 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range with LED and s 24/ C 3RP AQ unit CO contact 24/ A 3RP AP unit The same s 24/ C 3RP AQ unit potential must 24/ C 3RP AP unit be applied to terminals A s 24/ C 3RP AQ unit and B 24/ C 3RP AP unit RP15 40 timing relays, OFF-delay, without auxiliary voltage, time setting ranges 1) with LED and 1 CO contact s s s s s s s ) A 3RP AB unit ) A 3RP AJ unit ) A 3RP AN unit CO contacts ) A 3RP BB unit ) C 3RP BJ unit ) C 3RP BN unit RP15 55 timing relays, clock-pulse relay, 15 time setting ranges with LED and s / /60 5) C 3RP AR unit changeover s 24/ C 3RP AQ unit contact s s min s min min min h min h h h h 4) 24/ A 3RP AP unit RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range 3 NO contacts 3) wye-delta 24/ C 3RP SP unit (common contact root terminal 1) s, overtravel time (idling) s 3RP15. timing relays, wye-delta function 6), dead interval 50 ms, 1 time setting range 1 NO contact instantaneous and 1 NO contact delayed (common contact root terminal 1) s 24/ A 3RP15 4-2NP unit / B 3RP15 4-2NM unit s 24/ C 3RP15 6-2NQ unit / A 3RP15 6-2NP unit / B 3RP15 6-2NM unit Siemens LV /33

34 3RP Timing Relays Siemens AG 200 3RP15 timing relays in industrial enclosure, 22.5 mm Accessories Label sets 3RP A 3RP B Blank labels Version Function Identification letter Application DT PU Accessory for 3RP15 05 (not included in the scope of supply). The label set offers the possibility of labeling timing relays with the set function in English and German. 1 label With ON-delay A for } 3RP A 1 5 units set OFF-delay with auxiliary voltage B devices (1 unit) with 1 CO with 8 ON-delay and OFF-delay with C contact functions auxiliary voltage and Flashing, starting with interval D 3RP RW30 Passing make contact E Passing break contact with F auxiliary voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary H voltage 1 label ON-delay A for } 3RP B 1 5 units set OFF-delay with auxiliary voltage B devices (1 unit) with 2 CO with 16 ON-delay and OFF-delay with C contacts functions auxiliary voltage Flashing, starting with interval D Passing make contact E Passing break contact with F auxiliary voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary H voltage and instantaneous contact ON-delay and instantaneous A contact OFF-delay with auxiliary voltage B and instantaneous contact ON-delay and OFF-delay with C auxiliary voltage and instantaneous contact Flashing, starting with interval, D and instantaneous contact Passing make contact and E instantaneous contact Passing break contact with F auxiliary voltage and instantaneous contact Pulse-forming with auxiliary voltage G and instantaneous contact Wye-delta function * Blank labels, 20 mm x mm, pastel turquoise 1) C 3RT SB units Covering caps and push-in lugs Push-in lugs for screw mounting, 2 units are required for each device 3RP19 03 Sealable covers for securing against unauthorized adjustment of setting knobs 3RP ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. for devices with 1 or 2 CO contacts for devices with 1 or 2 CO contacts } 3RP units } 3RP units /34 Siemens LV 1 200

35 Siemens AG 200 3RP Timing Relays Overview LED for indicating "Timing relay excited" (left) LED for indicating "Relay switched" (right) Time setting range selector switch Device labeling plate NSB0_01424 Function switch Time setting range adjuster, analog 3RP20 timing relays, 45 mm Application Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings. Standards The timing relays comply with: EN "Environmental conditions" EN /DIN VDE 0435 Part 2021 "Electrical relays, timing relays" EN and EN "Electromagnetic compatibility" EN (VDE 0660 Part 200) "Low-voltage switchgear and controlgear" EN "Safe electrical isolation" Accessories Label set for marking the multifunction relay Siemens LV /35

36 3RP Timing Relays Siemens AG 200 3RP20 timing relays, 45 mm Selection and ordering data Multifunction The functions can be adjusted by means of rotary switches 1). Insert labels can be used to adjust different functions of the 3RP20 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. Version Time setting range Rated control supply DT Screw terminals PU voltage U s AC 50/60 Hz DC V V 3RP20 05 timing relays, multifunction, 15 time setting ranges with LED and s 24/ } 3RP AQ unit CO contact, s 24/ } 3RP AP unit functions 1)2) s with LED and s min ) D 3RP BW unit CO contacts, 16 functions 1) s min min min 3RP BW h min h h h h 3) 3RP timing relays, ON-delay, 15 time setting ranges with LED and s 24/ } 3RP AQ unit CO contact 2) s 24/ } 3RP AP unit s s min s min min min 3RP AP h min h h h h 3) 1) For functions, see 3RP label set. 2) Units with safe electrical isolation. 3) With switch position, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 4) Operating range x U s. 5) Operating range x U s. /36 Siemens LV 1 200

37 Siemens AG 200 3RP Timing Relays 3RP20 timing relays, 45 mm Selection and ordering data Multifunction The functions can be adjusted by means of rotary switches 1). Insert labels can be used to adjust different functions of the 3RP20 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. Version Time setting range t Rated control supply DT Spring-loaded terminals PU voltage U s AC 50/60 Hz DC V V 3RP20 05 timing relays, multifunction, 15 time setting ranges with LED and s 24/ D 3RP AQ unit CO contact, s 24/ } 3RP AP unit functions 1)2) s with LED and s min ) A 3RP BW unit CO contacts, 16 functions 1) s min min min h min h h h h 3) 3RP timing relays, ON-delay, 15 time setting ranges with LED and s 24/ D 3RP AQ unit CO contact 2) s 24/ A 3RP AP unit s s min s min min min h min h h h h 3) 1) For functions, see 3RP label set. 2) Units with safe electrical isolation. 3) With switch position, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 4) Operating range 0.8 to 1.1 x U s. 5) Operating range 0. to 1.1 x U s. Siemens LV /3

38 3RP Timing Relays Siemens AG 200 3RP20 timing relays, 45 mm Accessories Label sets 3RP A 3RP B Blank labels Version Function Identification letter Application Accessory for 3RP20 05 (not included in the scope of supply). The label set offers the possibility of labeling timing relays with the set function in English and German. 1 label set (1 unit) with 8 functions 1 label set (1 unit) with 16 functions With ON-delay A for OFF-delay with auxiliary voltage B ON-delay and OFF-delay with C auxiliary voltage Flashing, starting with interval D Passing make contact E Passing break contact with auxiliary F voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary H voltage With ON-delay A for OFF-delay with auxiliary voltage B ON-delay and OFF-delay with C auxiliary voltage Flashing, starting with interval D Passing make contact E Passing break contact with auxiliary F voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary H voltage and instantaneous contact ON-delay and instantaneous contact A OFF-delay with auxiliary voltage and B instantaneous contact ON-delay and OFF-delay with C auxiliary voltage and instantaneous contact Flashing, starting with interval, D and instantaneous contact Passing make contact and E instantaneous contact Passing break contact with auxiliary F voltage and instantaneous contact Pulse-forming with auxiliary voltage G and instantaneous contact Wye-delta function * devices with 1 CO contact and 3RP RW30 devices with 2 CO contacts DT PU } 3RP A 1 5 units } 3RP B 1 5 units Blank labels, 20 mm x mm, pastel turquoise 1) C 3RT SB units ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. /38 Siemens LV 1 200

39 Siemens AG 200 3RP Timing Relays 3RT19 timing relays for mounting onto contactors Selection and ordering data For contactors Auxiliary contacts Rated control Time setting DT Screw terminals PU range Function supply voltage Timing relay energized U s t Timing relay closed Contact open Type V s For size S00 1), with screw terminal Terminal designations according to EN Part 5 ON-delay (varistor integrated) 3RT10 1, 1 NO + 1 NC 24 AC/DC } 3RT EJ unit RH } 3RT EJ unit A1/A B 3RT EJ unit / AC C 3RT EC unit } 3RT EC unit / } 3RT EC unit RT t AC D 3RT ED unit } 3RT ED unit } 3RT ED unit OFF-delay without auxiliary voltage (varistor integrated) 2) 1 NO + 1 NC 24 AC/DC } 3RT FJ unit } 3RT FJ unit > 200 ms } 3RT FJ unit A1/A AC D 3RT FK unit / } 3RT FK unit B 3RT FK unit / AC D 3RT FL unit t } 3RT FL unit } 3RT FL unit OFF-delay with auxiliary voltage 1 CO contact 24 AC/DC B 3RT LJ unit A1/A AC B 3RT LC unit > 35 ms AC B 3RT LD unit B1/A2 15/18 15/16 t NSB00933 NSB00859 NSB00934 Wye-delta function (varistor integrated) 1 NO, delayed + 1 NO, instantaneous, dead time 50 ms 24 AC/DC } 3RT GJ unit AC D 3RT GC unit AC } 3RT GD unit A1/A2 Y 2/28, 3/38 t 50 ms NSB ) The terminals for the rated control supply voltage are connected to the contactor beneath by the integrated spring-type contacts of the solid-state time-delay auxiliary switch block when mounting. 2) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. Siemens LV /39

40 3RP Timing Relays Siemens AG 200 3RT19 timing relays for mounting onto contactors For contactors Auxiliary contacts Rated control Time setting DT Screw terminals PU range Function supply voltage Timing relay energized U s t Timing relay closed Contact open Type V s For sizes S0 to S12 2), with screw terminal ON-delay 3RT10 2, 1 NO + 1 NC 24 AC/DC D 3RT EJ unit RT10 3, } 3RT EJ unit RT A 3RT EJ unit A1/A AC C 3RT EC unit / } 3RT EC unit / D 3RT EC unit t AC D 3RT ED unit RT } 3RT ED unit B 3RT ED unit OFF-delay without auxiliary voltage 1) 1 NO + 1 NC 24 AC/DC } 3RT FJ unit } 3RT FJ unit > 200 ms } 3RT FJ unit A1/A AC D 3RT FK unit / } 3RT FK unit C 3RT FK unit / AC D 3RT FL unit t A 3RT FL unit A 3RT FL unit Wye-delta function 1 NO, delayed + 1 NO, instantaneous, dead time 50 ms NSB00936 NSB AC/DC } 3RT GJ unit AC } 3RT GC unit AC } 3RT GD unit A1/A2 Y -/-8, -/-8 t 50 ms NSB ) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. 2) The terminals A1 and A2 for the rated control supply voltage of the solidstate time-delay auxiliary switch block must be connected to the corresponding contactor by connecting cables. /40 Siemens LV 1 200

41 Siemens AG 200 3RP Timing Relays 3RT19 timing relays for mounting onto contactors For contactors Function Timing relay energized Contact closed Contact open Contactor energized Rated control supply voltage U s 1) Not for 3RT10 4 contactor with 24 to 42 V rated control supply voltage. Time setting range t DT Screw terminals PU Type V s For size S00, with semiconductor output and screw terminal For mounting onto the front of contactors The electrical connection between the time-relay block and the contactor beneath is established automatically when it is snapped on. 3RT C... 3RT D... 3RT1. 1, 3RH11 ON-delay, two-wire version (varistor integrated) AC/DC B 3RT CG unit A1/A2 Timing relay } 3RT CG unit B 3RT CG unit t AC/DC D 3RT CH unit A1/A2 Contactor } 3RT CH unit } 3RT CH unit OFF-delay with auxiliary voltage (varistor integrated) A1/A AC/DC C 3RT DG unit Timing relay B 3RT DG unit B1/A B 3RT DG unit > 35 ms A1/A AC/DC D 3RT DH unit Contactor } 3RT DH unit t B 3RT DH unit NSB00939a NSB00940a For sizes S0 to S3, with semiconductor output and screw terminal For mounting onto coil terminals on top of the contactors The electrical connection between the relay block and the corresponding contactor is established by screwing the two connecting pins of the time-relay block to coil terminals A1/A2 on top of the contactor. ON-delay, two-wire version (varistor integrated) 3RT10 2, 3RT10 3, A1/A AC/DC D 3RT CG unit RT10 4 1) Timing relay B 3RT CG unit D 3RT CG unit t A1/A AC/DC } 3RT CH unit Contactor } 3RT CH unit RT C } 3RT CH unit OFF-delay with auxiliary voltage (varistor integrated) AC/DC D 3RT DG unit A1/A2 Timing relay D 3RT DG unit B1/A D 3RT DG unit > 35 ms AC/DC C 3RT DH unit A1/A2 Contactor D 3RT DH unit t 3RT D C 3RT DH unit NSB00939a NSB00940a Siemens LV /41

42 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Siemens AG 200 Overview Application The relays are used above all for mobile equipment, e.g. air conditioning compressors, refrigerating containers, building site compressors and cranes. Solid-state line monitoring relays provide maximum protection for mobile machines and plants or for unstable networks. Network and voltage faults can be detected early and rectified before far greater damage ensues. Depending on the version, the relays monitor phase sequence, phase failure with and without N conductor monitoring, phase unbalance, undervoltage or overvoltage. The rms value of the voltage is measured. With the 3UG46 1 or 3UG46 18 relay, a wrong direction of rotation can also be corrected automatically. Function Phase sequence Phase failure Phase unbalance Undervoltage Overvoltage Application Direction of rotation of the operating mechanism A fuse has tripped Failure of the control supply voltage Broken cable Overheating of the motor due to asymmetrical voltage Detection of asymmetrically loaded networks Increased current on a motor with corresponding overheating Unintentional resetting of a device Network collapse, particularly with battery power Protection of a plant against destruction due to overvoltage Benefits Can be used without auxiliary voltage in any network from 160 to 690 V AC worldwide thanks to wide voltage range Variably adjustable to overvoltage, undervoltage or window monitoring Freely configurable delay times and reset response Width 22.5 mm Permanent display of ACTUAL value and network fault type on the digital variants Automatic correction of the direction of rotation by distinguishing between network faults and wrong phase sequence All versions with removable terminals All versions with screw terminal or alternatively with innovative spring-loaded terminal /42 Siemens LV 1 200

43 Selection and ordering data Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Hysteresis Undervoltage detection Overvoltage detection ON-delay Tripping delay Version of auxiliary contacts 1) 1 CO contact each and 1 tripping delay time each for U min and U max. Rated control supply voltage U s 2) 1 CO contact each for network fault and for phase sequence correction. DT Screw terminals PU s s CO contact V Monitoring of phase sequence Auto-RESET -- No No AC A 3UG AN unit A 3UG BN unit AC A 3UG AP unit A 3UG BP unit AC A 3UG AQ unit A 3UG BQ unit Monitoring of phase sequence, phase failure and phase unbalance Auto-RESET, closed-circuit principle, unbalance threshold 10 % -- No No AC A 3UG AR unit A 3UG BR unit Monitoring of phase sequence, phase failure, unbalance and undervoltage Analogically adjustable, Auto-RESET, closed-circuit principle, fixed unbalance threshold 20 % 5 % of set value Yes No AC A 3UG BR unit Digitally adjustable, Auto or manual RESET, open-circuit or closed-circuit principle, unbalance threshold % Adjustable Yes No AC A 3UG BR unit V Monitoring of phase sequence, phase failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Adjustable Yes Yes ) 2 1) AC A 3UG CR unit V Monitoring of phase sequence, phase and neutral conductor failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Adjustable Yes Yes ) 2 1) AC A 3UG CR unit V Automatic correction of the direction of rotation in case of wrong phase sequence, phase failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto or manual RESET, open-circuit or closed-circuit principle, unbalance threshold % Adjustable Yes Yes ) AC A 3UG46 1-1CR unit V Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto or manual RESET, open-circuit or closed-circuit principle, unbalance threshold % Adjustable Yes Yes ) AC A 3UG CR unit V Siemens LV /43

44 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Siemens AG 200 Hysteresis Undervoltage detection Overvoltage detection ON-delay Tripping delay Version of auxiliary contacts Rated control supply voltage U s DT Spring-loaded terminals PU s s CO contact V Monitoring of phase sequence Auto-RESET -- No No AC A 3UG AN unit A 3UG BN unit AC A 3UG AP unit A 3UG BP unit AC A 3UG AQ unit A 3UG BQ unit Monitoring of phase sequence, phase failure and phase unbalance Auto-RESET, closed-circuit principle, unbalance threshold 10 % -- No No AC A 3UG AR unit A 3UG BR unit Monitoring of phase sequence, phase failure, unbalance and undervoltage Analogically adjustable, Auto-RESET, closed-circuit principle, unbalance threshold 20 % 5 % of set value Yes No AC A 3UG BR unit Digitally adjustable, Auto or manual RESET, open-circuit or closed-circuit principle, unbalance threshold % Adjustable Yes No AC A 3UG BR unit V Monitoring of phase sequence, phase failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Adjustable Yes Yes ) 2 1) AC A 3UG CR unit V Monitoring of phase sequence, phase and neutral conductor failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Adjustable Yes Yes ) 2 1) AC A 3UG CR unit V Automatic correction of the direction of rotation in case of wrong phase sequence, phase failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto or manual RESET, open-circuit or closed-circuit principle, unbalance threshold % Adjustable Yes Yes ) AC A 3UG46 1-2CR unit V Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto or manual RESET, open-circuit or closed-circuit principle, unbalance threshold % Adjustable Yes Yes ) AC A 3UG CR unit V 1) 1 CO contact each and 1 tripping delay time each for U min and U max. 2) 1 CO contact each for network fault and for phase sequence correction. /44 Siemens LV 1 200

45 Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Accessories Blank labels Application Version DT PU Blank labels, 20 mm x mm, C 3RT SB pastel turquoise 1) units Push-in lugs and covers 3RP19 03 for devices with 1 or 2 CO contacts Push-in lugs for screw mounting, 2 units are required for each device } 3RP units for devices with 1 or 2 CO contacts Sealable covers for securing against unauthorized adjustment of setting knobs } 3RP units RP ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV /45

46 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Voltage monitoring Siemens AG 200 Overview Application Protection of a plant against destruction due to overvoltage Switch-on of a plant at a defined voltage and higher Protection against overloaded supply voltages, particularly with battery power Threshold switch for 0.1 to 10 V analog signals The relays monitor single-phase AC voltages (rms value) and DC voltages against the set threshold value for overshoot and undershoot. The products differ with regard to their power supply (internal or external). Benefits Variants with wide voltage supply range Variably adjustable to overvoltage, undervoltage or window monitoring Freely configurable delay times and RESET response Width 22.5 mm Display of ACTUAL value and status messages All versions with removable terminals All versions with screw terminals or alternatively with innovative spring-loaded terminals /46 Siemens LV 1 200

47 Selection and ordering data Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Voltage monitoring Measuring range Hysteresis Rated control supply voltage U s DT Screw terminals PU V AC/DC V AC/DC V AC/DC Internal power supply without auxiliary voltage, ON-delay and tripping delay can be adjusted separately s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact A 3UG AL unit Supplied from an external auxiliary voltage, tripping delay adjustable s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact A 3UG AA unit A 3UG AA unit A 3UG AW unit A 3UG AW unit Measuring range Hysteresis Rated control supply voltage U s DT Spring-loaded terminals PU V AC/DC V AC/DC V AC/DC Internal power supply without auxiliary voltage, ON-delay and tripping delay can be adjusted separately s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact A 3UG AL unit Supplied from an external auxiliary voltage, tripping delay adjustable s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact A 3UG AA unit A 3UG AA unit A 3UG AW unit A 3UG AW unit UG AA30 Accessories Blank labels Application Version DT PU Blank labels, 20 mm x mm, C 3RT SB units pastel turquoise 1) Push-in lugs and covers for devices Push-in lugs with 1 or 2 for screw mounting, CO contacts 2 units are required for each device 3RP19 03 for devices Sealable covers with 1 or 2 for securing against unauthorized CO contacts adjustment of setting knobs } 3RP units } 3RP units RP ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV /4

48 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Current monitoring Siemens AG 200 Overview Application Overcurrent and undercurrent monitoring Monitoring the functionality of electrical loads Open-circuit monitoring Threshold switch for analog signals from 4 to 20 ma The relays monitor single-phase AC currents (rms value) and DC currents against the set threshold value for overshoot and undershoot. They differ with regard to their measuring ranges and supply voltage types. Benefits Variants with wide voltage supply range Variably adjustable to overvoltage, undervoltage or window monitoring Freely configurable delay times and RESET response Width 22.5 mm Display of ACTUAL value and status messages All versions with removable terminals All versions with screw terminals or alternatively with innovative spring-loaded terminals /48 Siemens LV 1 200

49 Selection and ordering data Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Measuring range Hysteresis Rated control supply voltage U s DT Screw terminals PU Current monitoring AC/DC AC/DC V AC/DC Monitoring of undercurrent and overcurrent, ON-delay and tripping delay can be adjusted separately s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact ma ma 24 1) A 3UG AA unit A A A 3UG AA unit ma ma ) A 3UG AW unit A A A 3UG AW unit Measuring range Hysteresis Rated control supply voltage U s DT Spring-loaded terminals PU AC/DC AC/DC V AC/DC Monitoring of undercurrent and overcurrent, ON-delay and tripping delay can be adjusted separately s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact ma ma 24 1) A 3UG AA unit A A A 3UG AA unit ma ma ) A 3UG AW unit A A A 3UG AW unit UG AA30 1) No electrical isolation. Load supply voltage 24 V. 2) Electrical isolation between control circuit and measuring circuit. Load supply voltage for safe isolation max. 300 V, for simple isolation max. 500 V. Accessories Blank labels Application Version DT PU Blank labels, 20 mm x mm, C 3RT SB pastel turquoise 1) units Push-in lugs and covers 3RP19 03 for devices with 1 or 2 CO contacts for devices with 1 or 2 CO contacts Push-in lugs for screw mounting, 2 units are required for each device Sealable covers for securing against unauthorized adjustment of setting knobs } 3RP units } 3RP units RP ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV /49

50 Monitoring Relays Monitoring Relays for Electrical and Additional Measurements Power factor and active current monitoring Siemens AG 200 Overview Application No-load monitoring and load shedding, such as in the event of a V-belt tear Underload monitoring in the low performance range, e.g. in the event of pump no-load operation Monitoring of overload, e.g. due to a dirty filter system Simple power factor monitoring in networks for control of compensation equipment Broken cable between control cabinet and motor The 3UG46 41 power factor and active current monitoring device enables the load monitoring of motors. Whereas power factor monitoring is used above all for monitoring no-load operation, the active current monitoring option can be used to observe and evaluate the load factor over the entire torque range. Benefits Can be used world-wide thanks to wide voltage range from 90 to 690 V Monitoring of even small single-phase motors with a no-load supply current below 0.5 A Simple determination of threshold values throught the direct collection of measured variables on motor loading Window monitoring and active current measurement enable detection of cable breaks between control cabinets and motors, as well as phase failures Power factor or active current can be selected as measurement principle /50 Siemens LV 1 200

51 Siemens AG 200 Monitoring Relays Monitoring Relays for Electrical and Additional Measurements Power factor and active current monitoring Selection and ordering data Relay for monitoring the power factor and the active current, overshoot, undershoot or window monitoring, single and three-phase, overall width 22.5 mm Digitally adjustable, with LCD display Upper and lower threshold value can be adjusted separately 1 changeover contact each for undershoot/overshoot Permanent display of actual value and release status Measuring range Hysteresis ON-delay OFF-delay Rated control supply voltage U s AC 50/60 Hz for power factor for active current for power factor for active current DT Screw terminals PU P.f. A P.f. A s s V A 3UG CS unit Measuring range Hysteresis ON-delay OFF-delay Rated control supply voltage U s AC 50/60 Hz for power factor for active current for power factor for active current DT Spring-loaded terminals PU P.f. A P.f. A s s V A 3UG CS unit Accessories Blank labels Application Version DT PU Blank labels, 20 mm x mm, C 3RT SB units pastel turquoise 1) Push-in lugs and covers for devices Push-in lugs with 1 or for screw mounting, 2 CO contacts 2 units are required for each device 3RP19 03 for devices Sealable covers with 1 or for securing against unauthorized 2 CO contacts adjustment of setting knobs } 3RP units } 3RP units RP ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV /51

52 Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Insulation monitoring for ungrounded AC networks Overview Application The 3UG30 81 monitoring relay is suitable for insulation monitoring of AC systems with one or three phases in ungrounded networks (IT networks). Supply voltage The 3UG AK20 has alternative voltage terminals. Only one supply voltage is permitted to be connected to it! Terminals A1 and A2 are used to connect 230 V AC and terminals A1 and B2 are used to connect 115 V AC. The 3UG AW30 has a wide-range input of 24 to 240 V AC/DC on terminals A1 and A2. Relay for monitoring the insulation resistance between the ungrounded single or three-phase AC supply and a protective conductor Measuring principle with superimposed DC voltage Two selectable measuring ranges of kω Stepless setting within the measuring range Selectable: - Auto reset function with fixed hysteresis or - Storage of the tripping operation Test function with test button and terminal connections on the front Switching output: 1 CO contact Insulation fault indication with a red LED Supply voltage indication with a green LED Electro-magnetically compatible according to EN and EN Selection and ordering data Measuring range U e kω Insulation monitors for ungrounded AC networks Rated control supply voltage U s DT Screw terminals PU V / 230 AC A 3UG AK unit AC/DC B 3UG AW unit UG AK20 Accessories Sealable, transparent covers C 3UG A 1 1 unit /52 Siemens LV 1 200

53 Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Insulation monitoring for ungrounded DC networks Overview Application The 3UG30 82 monitoring relay has been designed for insulation monitoring in ungrounded, purely DC networks with or without filtering. It is mainly used to monitor ungrounded DC voltage networks as well as to monitor battery-powered systems. Supply voltage Due to the electrical isolation of the supply voltage and the measuring circuit, the relay can be used for DC networks in which the auxiliary voltage is either supplied externally or where the network to be monitored also serves as the power supply. Note: If the monitoring relay is supplied with an 230 V AC voltage, for example, the terminals A1 and L+ as well as A2 and L- must not be connected with each other! Relay for monitoring the insulation resistance between ungrounded purely DC networks and a protective conductor Measuring principle for differential current measurement Response value can be adjusted continuously from 10 to 110 kω Selectable - Auto reset function with hysteresis or - Storage of the tripping operation Front selector switch for open-circuit and closed-circuit principle for the output relay Test function with test buttons on the front for L+ and L- and over terminal connections Switching output: 1 CO contact Insulation fault indicator for L+ and L- through two red LEDs Supply voltage indication with a green LED Electro-magnetically compatible according to EN and EN Selection and ordering data Measuring range U e Rated control supply voltage U s DT Screw terminals PU V kω Insulation monitors for ungrounded DC networks AC/DC B 3UG AW unit UG AW30 Accessories Sealable, transparent covers C 3UG A 1 1 unit Siemens LV /53

54 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Level monitoring Siemens AG 200 Overview Application Single-point and two-point level monitoring Overflow protection Dry running protection Leak monitoring The 3UG35 01 level monitoring relay is used together with the 2- or 3-pole sensors to monitor the levels of conductive liquids. Selection and ordering data Standard rail mounting Width 22.5 mm Level monitoring relay for conductive liquids Inlet or outlet monitoring adjustable Sensitivity adjustment by potentiometer 1 yellow LED for indicating the relay state 1 green LED for indicating the applied control supply voltage 1 CO contact Version Sensitivity Rated control supply voltage U s AC 50/60 Hz AC 50/60 Hz Inlet or outlet monitoring (UNDER/OVER function) with switch, adjustable kω V DT Screw terminals PU } 3UG AC unit } 3UG AG unit } 3UG AL unit UG AC20 /54 Siemens LV 1 200

55 Siemens AG 200 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Level monitoring Sensors for level monitoring 3UG32 0-3A 3UG32 0-2A 3UG32 0-2B 3UG32 0-1B 3UG32 0-1C Version Assignment Application DT PU Cable Electrode Three-pole wire Brown Center The electrodes can } 3UG32 0-3A 1 1 unit electrodes electrode be cut or bent to 500 mm long, with the required length Teflon insulation White Not before or after (PTFE), screw-in Green assignable installation. The gland width A/F 22, Teflon insulation 3/8 inch thread, PVC must be removed connecting lead, over a length of 3 x 0.5 mm 2, 5 mm. 2 m long, max. operating temperature Applications: For 90 C, max. 2-point liquid level operating pressure control in an insulating 10 bar tank. One electrode each for the min. and max. value and a common reference electrode. Two-pole wire Brown electrodes White 500 mm long, with Teflon insulation (PTFE), screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm 2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar Two-pole bow electrodes with Teflon insulation (PTFE), screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm 2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar Single-pole bow electrodes for lateral fitting Screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm 2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar Single-pole bow electrodes for lateral fitting with Teflon insulation (PTFE), screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm 2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar Not assignable Brown Gland White Green Not assignable Brown Gland White Electrode Brown Gland White Electrode For installation see 3UG32 0-3A Application: For alarm indication in the event of overflow or low level and for 2-step liquid-level control, when the conductive tank is used as the reference electrode. Thanks to the small space requirements due to lateral fitting, ideal for use in small containers and pipes, as a leak monitor and level monitor or for warning of water entering an enclosure. } 3UG32 0-2A 1 1 unit } 3UG32 0-2B 1 1 unit As a max. value electrode for lateral fitting or for alarm indication in conductive tanks or pipes. } 3UG32 0-1B 1 1 unit For high flow velocities or for intensively sparkling fluids. C 3UG32 0-1C 1 1 unit Siemens LV /55

56 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Speed monitoring Siemens AG 200 Overview Application Slip or tear of a belt drive Standstill monitoring (no personal safety) Transport monitoring for completeness The 3UG30 51 monitoring relay is used together with a sensor to monitor operating mechanisms for underspeeding. Selection and ordering data Mounting onto standard mounting rail and screw fixing Width 45 mm Underspeed monitoring relay 4 measuring ranges adjustable on front panel 1 green LED for indicating the applied control supply voltage 1 yellow LED for indicating the relay state, flashes during the operating time T 1 CO contact Version Measuring range with or without storage, start-up override s, electrical isolation AC: Yes DC: No Measuring range Revolutions min (4 ranges) Rated control supply voltage U s AC 50/60 Hz DC DT Screw terminals PU V } 3UG AC unit } 3UG AG unit } 3UG AL unit ) } 3UG AC unit UG ) The rated control supply voltage and the measuring circuit are not electrically isolated /56 Siemens LV 1 200

57 Siemens AG 200 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, analogically adjustable, for 1 sensor Overview Application The analogically adjustable SIRIUS 3RS10/3RS11 temperature monitoring relays can be used in almost any application in which temperature overshoot or undershoot is not permitted, e.g. in the monitoring of set temperature limits and the output of alarm messages for: Motor and plant protection Control cabinet temperature monitoring Freeze monitoring Temperature limits for process variables, e.g. in the packaging industry or electroplating Controlling equipment and machines such as heating, climate and ventilation systems, solar collectors, heat pumps or warm water supplies Motor, bearing and gear oil monitoring Monitoring of coolants The 3RS10/3RS11 analog temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensors in the medium, evaluated by the device and monitored for overshoot or undershoot. When the threshold values are reached, the output relay switches on or off depending on the parameterization. Benefits All devices except for 24 V AC/DC feature electrical isolation Extremely easy operation using a rotary potentiometer Adjustable hysteresis Adjustable working principle for devices with 2 threshold values All versions with removable terminals All versions with screw terminals, many versions alternatively with innovative spring-type connections Siemens LV /5

58 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, analogically adjustable, for 1 sensor Selection and ordering data Siemens AG 200 Analogically adjustable evaluation units with one and two threshold values For analogically adjustable units, the threshold values and the hysteresis of 5 % applies. The product range has been developed for applications where a setting accuracy of ±5 % is suffi- hysteresis of 2 to 20 % are set using a rotary potentiometer. For units with 2 threshold values, the adjustable hysteresis only applies to threshold value 1. For the second threshold value, a cient. fixed Sensor Function Measuring range Rated control supply voltage U s AC 50/60 Hz DT Screw terminals PU C V Analogically adjustable, 1 threshold value, width 22.5 mm; closedcircuit principle; without memory; 1 NO + 1 NC PT100 Overshoot AC/DC B 3RS CD unit (resistance 110 / 230 AC B 3RS CK unit sensor) AC/DC B 3RS CD unit / 230 AC A 3RS CK unit AC/DC B 3RS CD unit / 230 AC A 3RS CK unit RS CD10 Type J (thermoelement) Undershoot AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit Overshoot AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit Overshoot AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit Analogically adjustable for warning and disconnection (2 threshold values), width 22.5 mm; open/closed-circuit principle switchable; without memory; 1 NO + 1 CO PT100 Overshoot AC/DC B 3RS DD unit (resistance AC/DC B 3RS DW unit sensor) AC/DC B 3RS DD unit AC/DC B 3RS DW unit AC/DC B 3RS DD unit AC/DC B 3RS DW unit RS DD40 Type J (thermoelement) Type K (thermoelement) Type K (thermoelement) Undershoot AC/DC B 3RS DD unit AC/DC B 3RS DW unit AC/DC B 3RS DD unit AC/DC B 3RS DW unit AC/DC B 3RS DD unit AC/DC B 3RS DW unit Overshoot AC/DC B 3RS DD unit AC/DC B 3RS DW unit AC/DC B 3RS DD unit AC/DC B 3RS DW unit Overshoot AC/DC B 3RS DW unit AC/DC B 3RS DW unit AC/DC B 3RS DD unit /58 Siemens LV 1 200

59 Analogically adjustable evaluation units with one and two threshold values For analogically adjustable units, the threshold values and the hysteresis of 2 to 20 % are set using a rotary potentiometer. For units with 2 threshold values, the adjustable hysteresis only applies to threshold value 1. Sensor Function Measuring range Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Rated control supply voltage U s AC 50/60 Hz Relays, analogically adjustable, for 1 sensor For the second threshold value, a fixed hysteresis of 5 % applies. The product range has been developed for applications where a setting accuracy of ±5 % is sufficient. DT Spring-loaded terminals PU C V Analogically adjustable, 1 threshold value, width 22.5 mm; closedcircuit principle; without memory; 1 NO + 1 NC PT100 (resistance sensor) Siemens AG 200 Overshoot AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit AC/DC B 3RS CD unit / 230 AC B 3RS CK unit Type J (thermoelement) Overshoot AC/DC B 3RS CD unit Analogically adjustable for warning and disconnection (2 threshold values), width 22.5 mm; open/closed-circuit principle switchable; without memory; 1 NO + 1 CO PT100 Overshoot AC/DC B 3RS DW unit (resistance sensor) Undershoot AC/DC B 3RS DD unit Type J (thermoelement) Overshoot AC/DC B 3RS DD unit Accessories Blank labels Application Version DT PU Blank labels, 20 mm x mm, C 3RT SB pastel turquoise 1) units Push-in lugs and covers 3RP19 03 for devices with 1 or 2 CO contacts for devices with 1 or 2 CO contacts Push-in lugs for screw mounting, 2 units are required for each device Sealable covers for securing against unauthorized adjustment of setting knobs } 3RP units } 3RP units RP ) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV /59

60 Siemens AG 200 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable, according to DIN 3440 for 1 sensor Overview The 3RS10/3RS11 temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensor in the medium, evaluated by the device and monitored for overshoot or undershoot or for staying within an operating range (window function). The 3RS10 40, 3RS20 40, 3RS11 40 and 3RS21 40 relays comply with the requirements of DIN 3440 as temperature monitors; the 3RS10 42 and 3RS11 42 relays comply with the requirements of DIN 3440 as temperature limiters. The relays are also an excellent alternative to temperature controllers in the low-end performance range (2 or 3-point closed-loop control). Benefits Very simple operation without complicated menu selections Certification according to DIN or 3-point closed-loop control can be configured quickly All versions with removable terminals All versions with screw terminals or alternatively with innovative spring-loaded terminals Application The 3RS10 40, 3RS10 42, 3RS11 40, 3RS11 42, 3RS20 40 and 3RS21 40 temperature monitoring relays can be used in almost any application in which temperature overshoot or undershoot is not permitted, e.g. in the monitoring of set temperature limits and the output of alarm messages for: Plant and environment protection Temperature limits for process variables e.g. in the packaging industry or electroplating Temperature limits for district heating plants Exhaust temperature monitoring Controlling equipment and machines such as heating, climate and ventilation systems, solar collectors, heat pumps or warm water supplies Motor, bearing and gear oil monitoring Monitoring of coolants The short-circuit and open-circuit detection as well as the measuring range is limited, depending on the sensor type. Measuring range in C for thermoelements Sensor type Short-circuit Open circuit 3RS11 40 Measuring range in C J -- x K -- x T -- x E -- x N -- x S -- x R -- x B -- x x Detection possible -- Detection not possible Measuring range in C for resistance sensors Sensor type Short-circuit Open circuit 3RS10 40/41 Measuring range in C 3RS11 42 Measuring range in C 3RS10 42 Measuring range in C PT100 x x PT1000 x x KTY x x KTY 84 x x NTC 1 ) x x Available -- Not available 1) Not for NTC B522-K333-A1 (100 C: 1.8 kω; 25 C: kω). /60 Siemens LV 1 200

61 Siemens AG 200 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable, according to DIN 3440 for 1 sensor Selection and ordering data Digitally adjustable evaluation units according to DIN 3440 The digitally adjustable temperature monitoring relays are very simple to operate. The three-digit LED display always shows the current temperature. A separate relay with an NO contact is included for sensor monitoring. The relay is switched off in parameterization mode. The following parameters can be adjusted: Sensor type 2 threshold values, ϑ1, ϑ2 1 hysteresis; applies to both thresholds ( K) 1 delay time; applies to both thresholds ( s) Open/closed-circuit principle switchable Manual/remote RESET Function: Overshoot or undershoot or window monitoring Wide-range voltage versions are electrically isolated. The temperature ranges depend on the sensor type. Sensor Measuring range (measuring range limit depends on the sensor) 1) NTC type: B522-K333-A1 (100 C: 1.8 kω; 25 C: kω). Rated control supply voltage U s AC 50/60 Hz V "Temperature monitors" according to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, memory function possible with external jumper, device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensors) 1) TYPE J, K, T, E, N (thermoelement) 3RS GD50 "Temperature limiters" and "Temperature monitors" according to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, tripping state and device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensors) 1) TYPE J, K, T, E, N, R, S, B (thermoelement) DT Screw terminals PU C 24 AC/DC A 3RS GD unit AC/DC A 3RS GW unit F 24 AC/DC B 3RS GD unit AC/DC B 3RS GW unit C 24 AC/DC A 3RS GD unit AC/DC B 3RS GW unit F 24 AC/DC B 3RS GD unit AC/DC B 3RS GW unit C 24 AC/DC B 3RS GD0 1 1 unit AC/DC B 3RS GW0 1 1 unit C 24 AC/DC B 3RS GD unit AC/DC B 3RS GW unit Siemens LV /61

62 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable, according to DIN 3440 for 1 sensor Digitally adjustable evaluation units according to DIN 3440 The digitally adjustable temperature monitoring relays are very simple to operate. The three-digit LED display always shows the current temperature. A separate relay with an NO contact is included for sensor monitoring. The relay is switched off in parameterization mode. Sensor Measuring range (measuring range limit depends on the sensor) 1) NTC type: B522-K333-A1 (100 C: 1.8 kω; 25 C: kω). Rated control supply voltage U s AC 50/60 Hz V "Temperature monitors" according to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, memory function possible with external jumper. device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensors) 1) TYPE J, K, T, E, N (thermoelement) The following parameters can be adjusted: Sensor type 2 threshold values, ϑ1, ϑ2 1 hysteresis; applies to both thresholds ( K) 1 delay time; applies to both thresholds ( s) Open/closed-circuit principle switchable Manual/remote RESET Function: Overshoot or undershoot or window monitoring Wide-range voltage versions are electrically isolated. The temperature ranges depend on the sensor type.. DT Spring-loaded terminals PU C 24 AC/DC B 3RS GD unit AC/DC B 3RS GW unit F 24 AC/DC C 3RS GD unit AC/DC C 3RS GW unit C 24 AC/DC B 3RS GD unit AC/DC B 3RS GW unit F 24 AC/DC C 3RS GD unit AC/DC C 3RS GW unit "Temperature limiters" and "Temperature monitors" according to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, tripping state and device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensors) 1) TYPE J, K, T, E, N, R, S, B (thermoelement) Siemens AG C 24 AC/DC C 3RS GD0 1 1 unit AC/DC C 3RS GW0 1 1 unit C 24 AC/DC C 3RS GD unit AC/DC C 3RS GW unit Accessories Blank labels Design Language used for labels DT PU Blank labels, 20 mm x mm, C 3RT SB units pastel turquoise 1) Replaceable cover labels for digital devices Replaceable cover labels for digital devices according to DIN 3440 German B 3RS A 1 5 units English B 3RS C 1 5 units Push-in lugs 3RP19 03 Push-in lugs for screw mounting, 2 units are required for each device Matching sensors can be found on the Internet at 1) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. } 3RP units /62 Siemens LV 1 200

63 Overview The 3RS10 41 temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensor in the medium, evaluated by the device and monitored for overshoot or undershoot or for staying within an operating range (window function). The evaluation unit can evaluate up to 3 resistance sensors at the same time and is specially designed for monitoring motor windings and bearings. Benefits Very simple operation without complicated menu selections Space-saving with 45 mm width All devices are available alternatively with spring-loaded terminals 2 or 3-point closed-loop control can be configured quickly All versions with removable terminals All versions with screw terminals or alternatively with innovative spring-loaded terminals Siemens AG 200 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable for up to 3 sensors Application The 3RS10 41 temperature monitoring relays can be used in almost any application in which several temperatures have to be monitored simultaneously for overshoot or undershoot or within a range. Monitoring of set temperature limits and output of alarm messages for: Plant and environment protection Temperature limits for process variables e.g. in the packaging industry or electroplating Controlling equipment and machines such as heating, climate and ventilation systems, solar collectors, heat pumps or warm water supplies Motor, bearing and gear oil monitoring Monitoring of coolants The short-circuit and open-circuit detection as well as the measuring range is limited, depending on the sensor type. Measuring range in C for resistance sensors Sensor type Open-circuit Short-circuit Measuring range in C PT100 x x PT1000 x x KTY x x KTY 84 x x NTC -- x x Available -- Not available Siemens LV /63

64 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable for up to 3 sensors Siemens AG 200 Selection and ordering data Digitally adjustable evaluation units The digitally adjustable temperature monitoring relays are very simple to operate. The three-digit LED display always shows the current temperature. A separate relay with an NO contact is included for sensor monitoring. The relay is switched off in parameterization mode. The following parameters can be adjusted: Sensor type 2 threshold values, ϑ1, ϑ2 1 hysteresis; applies to both thresholds ( K) 1 delay time; applies to both thresholds ( s) Open/closed-circuit principle Function: Overshoot or undershoot or window monitoring Wide-range voltage versions are electrically isolated. The temperature ranges depend on the sensor type. Sensor Number of sensors Measuring range Rated control DT Screw terminals PU supply voltage U s C V Motor monitoring relays, digitally adjustable for up to 3 sensors, width 45 mm; 1 CO + 1 CO + 1 NO PT100/1000; KTY83/84; NTC (resistance sensors) 1) 1 to 3 sensors AC/DC A 3RS GW unit RS GW50 1) NTC type: B522-K333-A1 (100 C: 1.8 kω; 25 C: kω). Sensor Number of sensors Measuring range Rated control DT Spring-loaded terminals PU supply voltage U s C V Motor monitoring relays, digitally adjustable for up to 3 sensors, width 45 mm; 1 CO + 1 CO + 1 NO PT100/1000; 1 to AC/DC B 3RS GW unit KTY83/84; sensors NTC (resistance sensors) 1) 1) NTC type: B522-K333-A1 (100 C: 1.8 kω; 25 C: kω). Accessories Blank labels Design Language used for labels DT PU Blank labels, 20 mm x mm, C 3RT SB units pastel turquoise 1) Replaceable cover labels for digital devices Replaceable cover labels for digital devices according to DIN 3440 German B 3RS B 1 5 units English B 3RS D 1 5 units Push-in lugs Push-in lugs for screw mounting, 2 units are required for each device } 3RP units RP19 03 Matching sensors can be found on the Internet at 1) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH /64 Siemens LV 1 200

65 Siemens AG 200 Monitoring Relays 3RN1 Thermistor Motor Protection For PTC sensors Overview Application Direct motor protection through temperature monitoring of the motor winding offers 100 % motor protection even under the most difficult ambient conditions, without the need to make adjustments on the device. Versions with hard gold-plated contacts ensure, in addition, a high switching reliability that is even higher than an electronic control. Motor protection: At increased ambient temperatures For high switching frequency For long start-up and braking procedures Used together with frequency converters (low speeds) Thermistor motor protection devices are used for direct monitoring of the motor winding temperature. For this purpose, the motors are equipped with temperature-dependent resistors (PTC) that are directly installed in the motor winding and abruptly change their resistance at their limit temperature. Benefits Thanks to direct motor protection, overdimensioning of the motors is not necessary No additional overload protection equipment is necessary No settings on the device are necessary Electronically optimized output thanks to variants with hard gold-plated contacts Rapid error diagnosis thanks to variants that indicate open- and short-circuit in the sensor circuit All versions with removable terminals All versions with screw terminals or alternatively with innovative spring-loaded terminals Siemens LV /65

66 Monitoring Relays 3RN1 Thermistor Motor Protection Siemens AG 200 For PTC sensors Selection and ordering data Thermistor motor protection relays for PTC thermistors (Type A PTCs) Monostable version with closed-circuit principle, triggers in the event of control supply voltage failure PTB01 ATEX approval, see LV 1 T "Technical Information". 3RN BW01: bistable version, does not trigger in the event of control supply voltage failure All devices except for 24 V AC/DC feature electrical isolation RESET Contacts Rated control supply voltage U s 50/60 Hz 1) The unit can be reset with the RESET button or by disconnecting the control supply voltage. 2) For more information on protection against voltage failure, see LV 1 T "Technical Information". DT Screw terminals PU V Compact signal evaluation units, width 22.5 mm, 1 LED Terminal A1 is jumpered with the root of the changeover contact Auto 1 CO 24 AC/DC } 3RN AB unit AC A 3RN AG unit AC } 3RN AM unit Standard evaluation units, width 22.5 mm, 2 LEDs Auto 1 NO + 1 NC 24 AC/DC } 3RN CB unit AC } 3RN CG unit AC } 3RN CM unit AC/DC } 3RN CW unit CO 24 AC/DC A 3RN BB unit AC A 3RN BG unit AC A 3RN BM unit CO, gold-plated 24 AC/DC B 3RN GB unit RN BB00 Manual/ 1 NO + 1 NC 24 AC/DC } 3RN CB unit Remote 1) 110 / 230 AC } 3RN CK unit Short-circuit detection for sensor circuit Manual/ 2 CO 24 AC/DC Remote 1) 110 AC A B 3RN BB00 3RN BG unit 1 unit AC A 3RN BM unit CO, gold-plated 24 AC/DC B 3RN GB unit Non-volatile 2) Manual/ 1 NO + 1 NC 24 AC/DC } 3RN CB unit Auto/ 3RN BW01 Remote 110 / 230 AC } 3RN CK unit Non-volatile 2), short-circuit detection in sensor circuit Manual/ Auto/ Remote 2 CO 24 AC/DC B 3RN BB unit AC B 3RN BG unit AC A 3RN BM unit CO, gold-plated 24 AC/DC B 3RN GB unit Non-volatile 2), short-circuit and open-circuit detection and indication in sensor circuit; wide-range voltage with screw terminal with safe isolation Manual/ 2 CO 24 AC/DC } 3RN BB unit Auto/ AC/DC } 3RN BW unit Remote 2 CO, gold-plated AC/DC B 3RN GW unit Evaluation units for 2 sensor circuits, warning and disconnection, width 22.5 mm, 3 LEDs Test / RESET button, non-volatile 2) Manual/ Auto/ Remote 1 NO + 1 CO AC/DC } 3RN DW unit Evaluation units for 6 sensor circuits, multiple motor protection, width 45 mm, 8 LEDs Test / RESET button, non-volatile 2) Manual/ Auto/ Remote 1 NO + 1 NC AC/DC } 3RN CW unit Bistable evaluation units, width 22.5 mm Test / RESET button, non-volatile 2), short-circuit and open-circuit detection and indication in sensor circuit Manual/ Auto/ Remote 2 CO AC/DC } 3RN BW unit /66 Siemens LV 1 200

67 Siemens AG 200 Monitoring Relays 3RN1 Thermistor Motor Protection Thermistor motor protection relays for PTC thermistors (Type A PTCs) Monostable version with closed-circuit principle, triggers in the event of control supply voltage failure PTB01 ATEX approval, see LV 1 T "Technical Information". For PTC sensors 3RN BW01: bistable version, does not trigger in the event of control supply voltage failure All devices except for 24 V AC/DC feature electrical isolation RESET Contacts Rated control supply voltage U s 50/60 Hz 1) The unit can be reset with the RESET button or by disconnecting the control supply voltage. 2) For more information on protection against voltage failure, see LV 1 T "Technical Information". DT Spring-loaded terminals PU V Compact signal evaluation units, width 22.5 mm, 1 LED Terminal A1 is jumpered with the root of the changeover contact Auto 1 CO 24 AC/DC A 3RN AB unit AC B 3RN AG unit AC B 3RN AM unit Standard evaluation units, width 22.5 mm, 2 LEDs Auto 1 NO + 1 NC 24 AC/DC } 3RN CB unit AC B 3RN CG unit AC A 3RN CM unit AC/DC A 3RN CW unit CO 24 AC/DC C 3RN BB unit AC C 3RN BG unit AC C 3RN BM unit RN CK00 2 CO, 24 AC/DC C 3RN GB unit gold-plated Manual/ 1 NO + 1 NC 24 AC/DC A 3RN CB unit Remote 1) 110 / 230 AC A 3RN CK unit Short-circuit detection for sensor circuit Manual/ 2 CO 24 AC/DC Remote 1) 110 AC C C 3RN BB00 3RN BG unit 1 unit AC B 3RN BM unit CO, 24 AC/DC C 3RN GB unit gold-plated Non-volatile 2) Manual/Auto/ 1 NO + 1 NC 24 AC/DC A 3RN CB unit Remote 110 / 230 AC B 3RN CK unit Non-volatile 2), short-circuit detection in sensor circuit Manual/Auto/ 2 CO 24 AC/DC C 3RN BB unit Remote 110 AC C 3RN BG unit AC C 3RN BM unit CO, gold-plated 24 AC/DC C 3RN GB unit Non-volatile 2), short-circuit and open-circuit detection and indication in sensor circuit; wide-range voltage with screw terminal with safe isolation Manual/Auto/ Remote 2 CO 24 AC/DC A 3RN BB unit AC/DC A 3RN BW unit CO, gold-plated AC/DC C 3RN GW unit Evaluation units for 2 sensor circuits, warning and disconnection, width 22.5 mm, 3 LEDs Test / RESET button, non-volatile 2) Manual/Auto/ 1 NO + 1 CO AC/DC B 3RN DW unit Remote Evaluation units for 6 sensor circuits, multiple motor protection, width 45 mm, 8 LEDs Test / RESET button, non-volatile 2) Manual/Auto/ 1 NO + 1 NC AC/DC B 3RN CW unit Remote Bistable evaluation units, width 22.5 mm Test / RESET button, non-volatile 2), short-circuit and open-circuit detection and indication in sensor circuit Manual/Auto/ 2 CO AC/DC B 3RN BW unit Remote Siemens LV /6

68 Monitoring Relays 3RN1 Thermistor Motor Protection Siemens AG 200 For PTC sensors Accessories Blank labels Application Version DT PU Blank labels, 20 mm x mm, C 3RT SB units pastel turquoise 1) Push-in lugs 3RP19 03 for devices with 1 or 2 CO contacts Push-in lugs for screw mounting, 2 units are required for each device 1) Computer labeling system for individual labeling of unit labeling plates available from: murrplastik Systemtechnik GmbH. } 3RP units /68 Siemens LV 1 200

69 Siemens AG 200 3TK28 Safety Relays Overview SIRIUS safety relays are the key elements of a consistent and cost-effective safety chain. Be it EMERGENCY-STOP disconnection, protective door monitoring or the protection of presses or punches with SIRIUS safety relays every safety application can be implemented to optimum effect in terms of engineering and price. SIRIUS safety relays provide numerous safety-related functions: Monitoring the safety functions of sensors Monitoring the sensor cables Monitoring the correct operation of the safety relay Monitoring the actuators (contactors) in the shutdown circuit Safety-oriented disconnection when dangers arise SIRIUS safety relays meet the highest requirements (Category 4) according to EN and achieve the highest safety integrity level (SIL 3) according to IEC Benefits General Data General Can be used for all safety applications thanks to compliance with the highest safety standards (Category 4 according to EN or SIL 3 according to IEC 61508) Suitable for use all over the world through compliance with all globally established certifications Compact, service-proven SIRIUS design creates more space in the control cabinet Flexible connectability and expendability make subsequent changes easy Removable terminals for greater plant availability Yellow front plate clearly identifies the device as an item of safety equipment Sensor cable up to 2000 m long enables use in large-scale plants Relay outputs Different voltages can be switched through the floating contacts Higher currents can be switched with relay contacts Solid-state outputs Wear-free Suitable for operation in fast switching applications Insensitive to vibrations and dirt Good electrical endurance Microprocessor systems Flexible use thanks to many different integrated functions Easy parameterization using DIP switches on the front High functional reliability based on extensive monitoring functions Operated by the machine control Also connection of non-contact sensors (light arrays, light barriers etc.) Application SIRIUS safety relays are used mainly in autonomous safety applications which are not connected to a safety-oriented bus system. Their function here is to evaluate the sensors and the safety-oriented shutdown of hazards. Also they check and monitor the sensors, actuators and safety-oriented functions of the safety relay. Siemens LV /69

70 3TK28 Safety Relays Siemens AG 200 With electronic enabling circuits Selection and ordering data Type 3TK TK TK28 42 Basic units Basic units Basic units t v Sensors Input Solid-state -- With contacts Safety mats -- Start Auto Monitored Cascading input 24 V DC -- Key-operated switches Enabling circuit, floating Stop category Stop category Enabling circuit, solid-state Stop category 0 2 1) 2 1 Stop category Signaling outputs Floating Solid-state Category according to EN max SIL level max Rated control supply voltage 24 V DC = Available -- = Not available 1) The outputs are only safe when an external contactor is used. /0 Siemens LV 1 200

71 Siemens AG 200 3TK28 Safety Relays With electronic enabling circuits Rated control supply voltage U s V OFF-delay t v DT Screw terminals PU s Rated control supply voltage U s 24 V DC 3TK28 40 basic units 24 DC -- A 3TK BB unit TK28 41 basic units 24 DC -- A 3TK BB unit TK BB40 3TK28 42 basic units t v 24 DC A 3TK BB unit A 3TK BB unit A 3TK BB unit TK BB41 Rated control supply voltage U s V OFF-delay t v DT Spring-loaded terminals PU s Rated control supply voltage U s 24 V DC 3TK28 40 basic units 24 DC -- B 3TK BB unit TK28 41 basic units 24 DC -- A 3TK BB unit TK28 42 basic units t v 24 DC B 3TK BB unit A 3TK BB unit B 3TK BB unit Accessories Push-in lugs and covers 3RP19 03 Version DT Push-in lugs for screw mounting, 2 units are required for each device Sealable covers for securing against unauthorized adjustment of setting knobs PU } 3RP units } 3RP units RP19 02 Siemens LV /1

72 3TK28 Safety Relays Siemens AG 200 With relay enabling circuits Selection and ordering data Type 3TK TK TK TK TK TK28 2 3TK TK TK TK28 35 Basic units Basic units Basic units Basic units Basic units Basic units Basic units Expansion units Two-hand control units Slowing down test apparatus t v t v Sensors Input Solid-state With contacts 1) Safety mats Start Auto Monitored Cascading input 24 V DC Key-operated switches Enabling circuit, floating Stop category 0 3 NO 2 NO 2 NO 2 NO 3 NO 2 NO 2 NO 4 NO 2 NO+2 NC 3 NO+2 NC Stop category NO 2 NO Enabling circuit, solid-state Stop category Stop category Signaling outputs Floating 1 NC NC 1 NC 1 NC Solid-state Category according Corresponds to EN max 3 2) ) 4 4 3) 4 3) to basic unit 4 4 SIL level max Corresponds to basic unit Rated control supply voltage 24VDC VAC/DC VAC V AC V AC V AC/DC = Available -- = Not available 1) The ON button is not monitored. 2) Depending on the hazard assessment, additional measures may be necessary in the sensor circuit (e.g. protected laying). 3) Only possible for instantaneous enabling contacts, otherwise Category 3. 4) For expansion of Siemens safety products. /2 Siemens LV 1 200

73 Siemens AG 200 3TK28 Safety Relays With relay enabling circuits Rated control supply voltage U s V OFF-delay t v DT Screw terminals PU s 3TK CB30 3TK CB30 3TK28 2-1CB31 3TK CB40 Rated control supply voltages U s 24 V DC and 50/60 Hz 24, 115, 230 V AC 3TK28 21 basic units 24 AC/DC -- } 3TK CB unit TK28 22 basic units 24 AC/DC -- } 3TK CB unit TK28 23 basic units 24 AC/DC -- } 3TK CB unit TK28 24 basic units 24 AC/DC -- } 3TK CB unit DC -- } 3TK BB unit AC -- A 3TK AJ unit AC -- } 3TK AL unit TK28 25 basic units 24 DC -- } 3TK BB unit AC -- A 3TK AB unit AC -- } 3TK AJ unit AC -- } 3TK AL unit TK28 2 basic units t v 24 DC } 3TK28 2-1BB unit AC B 3TK28 2-1AB unit AC B 3TK28 2-1AJ unit AC A 3TK28 2-1AL unit DC } 3TK28 2-1BB unit AC A 3TK28 2-1AB unit AC } 3TK28 2-1AJ unit AC } 3TK28 2-1AL unit TK28 28 basic units t v 24 DC } 3TK BB unit AC B 3TK AB unit AC B 3TK AJ unit AC A 3TK AL unit DC } 3TK BB unit AC B 3TK AB unit AC A 3TK AJ unit AC A 3TK AL unit TK28 30 expansion units 24 AC/DC -- } 3TK CB unit AC A 3TK AJ unit AC A 3TK AL unit TK28 34 two-hand control units 24 DC -- } 3TK BB unit AC A 3TK AB unit AC A 3TK AJ unit AC A 3TK AL unit TK28 35 slowing down test apparatus 24 DC -- B 3TK BB unit AC -- B 3TK AJ unit AC -- B 3TK AL unit Siemens LV /3

74 3TK28 Safety Relays Siemens AG 200 With relay enabling circuits Rated control supply voltage U s V OFF-delay t v DT Spring-loaded terminals PU s Rated control supply voltages U s 24 V DC and 50/60 Hz 24, 115, 230 V AC 3TK28 21 basic units 24 AC/DC -- } 3TK CB unit TK28 22 basic units 24 AC/DC -- A 3TK CB unit TK28 23 basic units 24 AC/DC -- A 3TK CB unit TK28 24 basic units 24 AC/DC -- A 3TK CB unit DC -- } 3TK BB unit AC -- B 3TK AJ unit AC -- B 3TK AL unit TK28 25 basic units 24 DC -- } 3TK BB unit AC -- B 3TK AB unit AC -- B 3TK AJ unit AC -- B 3TK AL unit TK28 2 basic units t v 24 DC A 3TK28 2-2BB unit AC B 3TK28 2-2AB unit AC B 3TK28 2-2AJ unit AC B 3TK28 2-2AL unit DC A 3TK28 2-2BB unit AC B 3TK28 2-2AB unit AC B 3TK28 2-2AJ unit AC B 3TK28 2-2AL unit TK28 28 basic units t v 24 DC A 3TK BB unit AC C 3TK AB unit AC B 3TK AJ unit AC B 3TK AL unit DC } 3TK BB unit AC B 3TK AB unit AC B 3TK AJ unit AC B 3TK AL unit TK28 30 expansion units 24 AC/DC -- } 3TK CB unit AC B 3TK AJ unit AC B 3TK AL unit TK28 34 two-hand control units 24 DC -- A 3TK BB unit AC B 3TK AB unit AC B 3TK AJ unit AC B 3TK AL unit TK28 35 slowing down test apparatus 115 AC -- B 3TK AJ unit AC -- B 3TK AL unit Accessories Push-in lugs and covers 3RP19 03 Version DT Push-in lugs for screw mounting, 2 units are required for each device Sealable covers for securing against unauthorized adjustment of setting knobs PU } 3RP units } 3RP units RP19 02 /4 Siemens LV 1 200

75 Siemens AG 200 3TK28 Safety Relays With contactor relay enabling circuits Selection and ordering data Type 3TK TK TK TK TK TK28 5 Basic units Basic units Basic units Basic units Expansion units 1) Expansion units 1) t v Sensors Input Solid-state With contacts Safety mats Start Auto Monitored Cascading input 24 V DC Key-operated switches Enabling circuit, floating Stop category 0 3 NO 2 NO 6 NO 3 NO 6 NO -- Stop category NO Enabling circuit, solid-state Stop category Stop category Signaling outputs Floating -- 1 NC 1 NC -- 1 NC -- Solid-state Category according to EN max Corresponds to basic unit Corresponds to basic unit SIL level max Rated control supply voltage 24VDC 24VAC/DC VAC V AC V AC V AC/DC Rated operational voltage 24VDC 230 V AC 600 V AC Switching capacity AC-15 at U = 230 V DC-13 at U = 24 V = Available -- = Not available 1) For expansion of Siemens safety products. Siemens LV /5

76 3TK28 Safety Relays Siemens AG 200 With contactor relay enabling circuits Rated control supply voltage U s V OFF-delay t v DT With screw terminals PU s Rated control supply voltages U s 24 V DC and 50/60 Hz, 115, 230 V AC 3TK28 50 basic units 24 DC -- A 3TK BB unit AC B 3TK AJ unit AC B 3TK AL unit TK28 51 basic units 24 DC -- B 3TK BB unit AC B 3TK AJ unit AC B 3TK AL unit TK28 52 basic units 24 DC -- A 3TK BB unit AC B 3TK AL unit TK28 53 basic units 24 DC -- A 3TK BB unit TK28 56 expansion units 24 DC -- B 3TK BB unit TK28 5 expansion units t v 24 DC B 3TK28 5-1BB unit DC B 3TK28 5-1BB unit DC B 3TK28 5-1BB unit Rated control supply voltage U s V OFF-delay t v DT With spring-loaded terminals PU s Rated control supply voltages U s 24 V DC and 50/60 Hz, 115, 230 V AC 3TK28 50 basic units 24 DC -- B 3TK BB unit AC B 3TK AJ unit AC B 3TK AL unit TK BB40 3TK28 51 basic units 24 DC -- B 3TK BB unit AC B 3TK AJ unit AC B 3TK AL unit TK BB40 3TK28 52 basic units 24 DC -- B 3TK BB unit AC B 3TK AL unit TK BB40 3TK28 53 basic units 24 DC -- B 3TK BB unit TK28 56 expansion units 24 DC -- B 3TK BB unit TK28 5 expansion units t v 24 DC B 3TK28 5-2BB unit B 3TK28 5-2BB unit C 3TK28 5-2BB unit /6 Siemens LV 1 200

Monitoring and Control Devices

Monitoring and Control Devices Monitoring and Control Devices /2 Introduction SIMOCODE 3UF Motor Management and Control Devices /6 SIMOCODE pro 3UF motor management and control devices /16 3UF18 current transformers for overload protection

More information

SIRIUS Motor Management and Control Devices

SIRIUS Motor Management and Control Devices Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases

More information

Siemens AG SIMOCODE 3UF Motor Management and

Siemens AG SIMOCODE 3UF Motor Management and Monitoring and Control Devices /2 Introduction SIMOCODE 3UF Motor Management and Control Devices /6 SIMOCODE pro 3UF motor management and control devices /32 3UF18 current transformers for overload protection

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

Siemens.com/industrial-controls

Siemens.com/industrial-controls SIRIUS Industrial Controls List 2018 Siemens.com/industrial-controls List of Contents Motor Control and Protection Soft Starters Motor Management - Simocode Monitoring Relays Commanding and Signaling Devices

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

Siemens AG /24RC 12/24RCo

Siemens AG /24RC 12/24RCo Siemens AG 008 Introduction Micro Automation LOGO!: Technology with a future which simplifies many things The compact, user-friendly and low-cost solution for simple control tasks. For universal applications

More information

Power Management System. Multifunction Measuring Instruments

Power Management System. Multifunction Measuring Instruments Power Management System Multifunction Measuring Instruments Power Management System /2 - System overview /2 - More information PAC3200 Multifunction Measuring Instruments /3 - Overview /4 - Benefits /5

More information

SIRIUS 3RB2 Solid-State Overload Relays

SIRIUS 3RB2 Solid-State Overload Relays SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

Parametrization, Configuration and Visualization with SIRIUS

Parametrization, Configuration and Visualization with SIRIUS Parametrization, Configuration and Visualization with SIRIUS Price Groups PG 1, 131, 191, 200 /2 Introduction /5 Soft Starter ES /8 SIRIUS 3RW44 soft starter block library for SIMATIC PCS 7 new /10 Motor

More information

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0

More information

LOGO! Simply different simply ingenious

LOGO! Simply different simply ingenious LOGO! Simply different simply ingenious Switching and controlling the profitable way Profitable companies have vision they maintain their competitive edge by using new technologies that are always a step

More information

Power Management System. Measuring Devices for Power Distribution

Power Management System. Measuring Devices for Power Distribution Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview

More information

Motor control and protection Universal Motor Controller UMC100-FBP

Motor control and protection Universal Motor Controller UMC100-FBP Motor control and protection Universal Motor Controller UMC100-FBP Universal motor controllers from ABB the intelligent on-site solution. Large industrial plants often contain several thousand motors in

More information

LOGO! Basic Integrated Liquid Crystal Display. Integrated soft keys for programming Integrated 8 DI & 4 DO.

LOGO! Basic Integrated Liquid Crystal Display. Integrated soft keys for programming Integrated 8 DI & 4 DO. 1. Introduction The compact, easy-to-use and low-cost solution for simple control tasks involving digital inputs and outputs, analog inputs without any complex logic and networking. "All in one": Integrated

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00 Monitoring functions Evaluation of brush length monitoring, digital, non-floating Evaluation of brush length monitoring, digital, floating A00 A06 Non-floating brush length monitoring with use of KM01

More information

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview Siemens AG 2010 Overview Benefits Can be used without auxiliary voltage in any network from 160 to 600 V AC worldwide thanks to wide voltage range Variably adjustable to overvoltage, undervoltage or range

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry. Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents

More information

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls SIRIUS Modular System. The perfect combination Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls Everything for the control cabinet: the SIRIUS

More information

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

Siemens AG up to 12 up to 25 up to 50 up to 100 up to 200 up to S12 Terminal brackets for stand-alone

Siemens AG up to 12 up to 25 up to 50 up to 100 up to 200 up to S12 Terminal brackets for stand-alone Siemens G 2007 Protection Equipment Introduction Type 3RU11 3RB20 3RB21 3RB22/3RB23 Overload relays up to 630 pplications System protection 1) 1) 1) 1) Motor protection lternating current, 3-phase lternating

More information

LOGO! logic module. 2/2 Introduction 2/2 LOGO! logic module 2/2 SIPLUS LOGO!

LOGO! logic module. 2/2 Introduction 2/2 LOGO! logic module 2/2 SIPLUS LOGO! 2/2 Introduction 2/2 2/2 SIPLUS LOGO! 2/3 2/3 basic variants 2/6 SIPLUS basic variants 2/7 pure variants 2/10 SIPLUS pure variants 2/12 expansion modules 2/16 SIPLUS expansion modules 2/18 LOGO! CM EIB/KNX

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General

More information

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours! Data sheet MK 20 GR Customized solution or off-the-shelf: The choice is yours! MK20-GR data sheet Looking for a quick and reliable solution? Then rely on our standard products: Our universal controls provide

More information

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS Overload Relays www.siemens.com/sirius SIRIUS 3RB24

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry. Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Press Shop

More information

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

SIMATIC S Central processing units

SIMATIC S Central processing units SIMATIC S7-1500 Siemens AG 2013 Overview CPU 1511-1 PN PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under

More information

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

Industrial Controls Product Catalog 2017

Industrial Controls Product Catalog 2017 Industrial Controls Product Catalog 2017 SIRIUS Section c o n t e n t s Thermal overload relays Solid state overload relays OVERLOAD RU21 overload relays up to 100 A with screw connection, CLASS 10 Page

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

SIRIUS Modular System

SIRIUS Modular System SIRIUS Modular System Highly flexible system-based switching, protecting and starting siemens.com/sirius Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Contents SIRIUS

More information

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay Introduction Siemens AG 014 System components Overload and s By combining overload/ s with it is now possible to send data that has already been recorded and evaluated in the s directly to the controller.

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface, Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,

More information

Take off! Enter into a New Dimension of Flexibility: SIMOCODE pro. sirius MOTOR MANAGEMENT

Take off! Enter into a New Dimension of Flexibility: SIMOCODE pro. sirius MOTOR MANAGEMENT Take off! Enter into a New Dimension of Flexibility: SIMOCODE pro sirius MOTOR MANAGEMENT The new generation: SIMOCODE pro takes off. In many automated processes, plant downtimes have proven themselves

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed

More information

LOGO! logic modules LOGO! basic and expansion modules

LOGO! logic modules LOGO! basic and expansion modules Siemens AG 018 LOGO! basic modules with display Overview The space-saving basic variants Interface for the connection of expansion modules, up to 4 digital inputs, 0 digital outputs, 8 analog inputs and

More information

The complete universe of Industrial Controls. You have it at your fingertips. sirius

The complete universe of Industrial Controls. You have it at your fingertips. sirius The complete universe of Industrial Controls. You have it at your fingertips. sirius Control room Bodyshop Powertrain Assembly Paintshop Equipping, handling, transporting basic functions such as these

More information

Control Circuit Components

Control Circuit Components Control Circuit Components, IO Link I/O Modules for Operation 6/2 Introduction in the Control Cabinet, IP20 6/2 Transmission technology 6/101 Introduction 6/3 Configuration examples 6/102 SlimLine 6/4

More information

IEC Power Control Overload Relays

IEC Power Control Overload Relays IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU21 overload relays up to 100 A with screw connection, CLASS 10 Page Selection and ordering data

More information

SIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry.

SIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry. SIRIUS Monitoring and Controlling Overview of safety relays Safety Integrated Answers for industry. Simpler, faster and more cost-effective to implement a seamless safety chain Today, one of the key success

More information

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT In panel and on machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT Changing the way panels... Reduce cost throughout

More information

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications siemens.com/sirius Answers for industry. SIRIUS 3RB24

More information

IEC Power Control Overload Relays

IEC Power Control Overload Relays IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU11 / 3RU1 overload relays up to 100 A with screw connection, CLASS 10 Page 3RB4 overload relays

More information

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB Universal Motor Controller UMC-FBP Excellent motor protection and control ATEX ABB FieldBusPlug: the concept ABB s communicative product family comprises a wide range of switching, controlling and automation

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Easy, efficient and always up to date the SIRIUS modular system

Easy, efficient and always up to date the SIRIUS modular system Easy, efficient and always up to date the SIRIUS modular system siemens.com/sirius Easy, efficient and always up to date, that s how industrial controls can be! Switching Protecting Starting Monitoring

More information

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1 4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

Control Transformers Control transformers

Control Transformers Control transformers Control Transformers It is often desirable to operate the control circuit at a lower voltage than the power circuit. Control transformers are used to step a voltage down to a lower level. Siemens Class

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional

More information

Laboratory automation

Laboratory automation Siemens AG 2008 Laboratory automation /2 SIMATIC PCS 7 LAB: Compact control system for the laboratory automation Siemens ST PCS 7.1 Update October 2008 Laboratory automation Siemens AG 2008 Overview PCS

More information

3RP, 7PV Timing Relays

3RP, 7PV Timing Relays 3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Relays. SIRIUS 3RR24 Monitoring Relays for Mounting onto 3RT2 Contactors for IO-Link. Current and active current monitoring. 10/80 Siemens IC

Relays. SIRIUS 3RR24 Monitoring Relays for Mounting onto 3RT2 Contactors for IO-Link. Current and active current monitoring. 10/80 Siemens IC SIRIUS 3RR24 Monitoring for Mounting onto 3RT2 Contactors for IO-Link Current and active current monitoring Benefits Can be mounted directly on 3RT2 contactors and 3RA23 reversing contactor assemblies,

More information

easyrelay Control Relays MFD-Titan Multi-Function Display

easyrelay Control Relays MFD-Titan Multi-Function Display easyrelay Control Relays MFD-Titan Multi-Function Display The easy500/easy700/800 control relays as well as the MFD-Titan multi-function display come with a full range of technical resources to implement

More information

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens

More information

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories / SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in

More information

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45 Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

4/0 EASY control relay

4/0 EASY control relay 4/0 DEL ALT ESC OK Contents 4/1 Page System overview 4/2 4/4 EASY800 networking 4/4 4/5 Basic units 4/5 Expansion units 4/9 Multi-function display 4/8 Display/operator unit 4/8 Power supply/cpu modules

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

Siemens tiastar TM Motor Control Center (MCC)

Siemens tiastar TM Motor Control Center (MCC) Siemens tiastar TM Motor Control Center (MCC) Page 1 Siemens 2011. All rights reserved. tiastar Motor Control Centers Smart tiastar Motor Control Centers Smart June 2013 Page 2 tiastar Motor Control Centers

More information

Industrial Communication

Industrial Communication Siemens AG 01 Industrial Communication Price groups 5K1, 5K, 5N3, 41B, 41H, 4C, 4D, 4F, 4J, 30, 50 / Introduction Introduction /11 Transmission technology /1 Communication overview specification /13 -

More information

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations Introduction 1 Configuring a reversing starter 2 Industrial Controls A List of abbreviations Motor management and control devices Getting Started 05/2018 A5E40507294002A/RS-AB/002 Legal information Warning

More information

Overload Relays 3RU Thermal Overload Relays 3RB Solid State Overload Relays 3UF SIMOCODE pro Intelligent Motor Protection

Overload Relays 3RU Thermal Overload Relays 3RB Solid State Overload Relays 3UF SIMOCODE pro Intelligent Motor Protection IEC Power Control Product Overview Alphabetical Product and Catalog Number Index MSPs 3RV20 Motor Starter Protectors 3RV27 & 3RV28 Circuit Breakers 3RA19/29 & 3RV19/29 Accessories 1 Contactors 3RT, 3TF,

More information

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview Siemens AG 200 Monitoring Relays Line monitoring Overview Solid-state line monitoring relays provide maximum protection for mobile machines and plants or for unstable networks. Network and voltage faults

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

3.3. Control Relays and Timers

3.3. Control Relays and Timers . Contents Description easy500/700/800..... easy802/806 with SmartWire-DT.................... easyrelay and MFD Expansion Modules..... MFD-Titan Multi-Function s......... easyrelay Communication Modules........

More information

7KT/7KM PAC Measuring Devices

7KT/7KM PAC Measuring Devices s SENTRON 7KT/ A device to suit every requirement Fully informed at all times thanks to intelligent measuring technology The 7KT/7KM PAC measuring devices ensure precise and reliable measurement of power

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

3RV1 Circuit-Breakers

3RV1 Circuit-Breakers SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a

More information

Safety is a SIRIUS business

Safety is a SIRIUS business SIRIUS 3SK Safety Relays Safety is a SIRIUS business Safety Relays for compact safety applications usa.siemens.com/safety-relays Safety is a SIRIUS business Machines can be dangerous. Personnel need to

More information

Product type designation. Control elements. Installation type/mounting

Product type designation. Control elements. Installation type/mounting Datasheet SIMATIC HMI KP32F PN, KEY PANEL, 32 SHORT-STROKE KEYS WITH MULTI-COLOR LED'S, PROFINET INTERFACES WITH PROFISAFE, 16DI+16DI/DO, 4 SAFETY DI PINS, 24V DC LOOP THROUGH CONFIGURABLE FROM STEP7 V5.5

More information

Motor control and protection Universal Motor Controller UMC100-FBP

Motor control and protection Universal Motor Controller UMC100-FBP Motor control and protection Universal Motor Controller UMC100-FBP Universal motor controller from ABB the intelligent on-site solution. Large industrial plants often have several thousand motors to provide

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Power Supplies & Logic Modules

Power Supplies & Logic Modules Power Supplies & Logic Modules Industrial Controls Product Catalog 2017 Section contents Introduction /2 SITOP Selection Tool /3 Selection tables for power supplies /4 /5 SITOP compact Introduction /6

More information

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES 2 power sources automatic transfer switch controllers The automatic transfer switch controllers ATL 600 - ATL 610 - ATL 800 can supervise and manage the

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information