Maximizing System x and ThinkServer Performance with a Balanced Memory Configuration

Size: px
Start display at page:

Download "Maximizing System x and ThinkServer Performance with a Balanced Memory Configuration"

Transcription

1 Front cover Maximizing System x and ThinkServer Performance with a Balanced Configuration Last Update: October 2017 Introduces three balanced memory guidelines for Intel Xeon s Compares the performance of balanced and unbalanced memory configurations Explains memory interleaving and its importance Provides tips on how to balance memory Dan Colglazier Joseph Jakubowski Tristian Truth Brown

2 Abstract Configuring a server with balanced memory is important for maximizing its memory bandwidth and overall performance. Lenovo servers running Intel Xeon s have 4 or 8 memory channels per and up to three DIMMs per channel, so it is important to understand what is considered a balanced configuration and what is not. In this paper, we introduce three balanced memory guidelines that will guide you to select a balanced memory configuration. Balanced and unbalanced memory configurations are presented along with their relative measured memory bandwidths to show the effect of unbalanced memory. Suggestions are also provided on how to produce balanced memory configurations. This paper is for System x and ThinkServer customers and for business partners and sellers wishing to understand how to maximize the performance of Lenovo servers. At Lenovo Press, we bring together experts to produce technical publications around topics of importance to you, providing information and best practices for using Lenovo products and solutions to solve IT challenges. See a list of our most recent publications at the Lenovo Press web site: Do you have the latest version? We update our papers from time to time, so check whether you have the latest version of this document by clicking the Check for Updates button on the front page of the PDF. Pressing this button will take you to a web page that will tell you if you are reading the latest version of the document and give you a link to the latest if needed. While you re there, you can also sign up to get notified via whenever we make an update. Contents Introduction interleaving Balanced memory configurations About the STREAM test topology Applying the balanced memory guidelines - E5 s Applying the balanced memory guidelines - E7 s Maximizing memory bandwidth Cluster on Die option impact on memory bandwidth Summary Change history Authors Notices Trademarks Maximizing System x and ThinkServer Performance with a Balanced Configuration

3 Introduction The memory subsystem is a key component of the Intel Xeon architecture of Lenovo servers which can affect overall server performance. When properly configured, the memory subsystem can deliver extremely high memory bandwidth and low memory access latency. When the memory subsystem is incorrectly configured, however, the memory bandwidth available to the server can become limited and overall server performance can be reduced. This brief explains the concept of balanced memory configurations that yield the highest possible memory bandwidth from the Intel Xeon architecture. Examples of balanced and unbalanced memory configurations are shown to illustrate their effect on memory subsystem performance. This paper is applicable to servers based on Intel v4 and upcoming E7 v4 s as well as the previous generation v3 and E7 v3 families. interleaving Access to the information stored on memory DIMMs is controlled by the memory controller(s) within the Intel Xeon. Depending on the specific, one or two memory controllers are present in each. Each memory controller is attached to memory channels that are connected to the physical connectors that interface to memory DIMMs. Figure 1 on page 3 illustrates how an Intel E5 s memory controllers are connected to DIMM s. Slot 0 Slot 1 Slot 2 Slot 0 Slot 1 Slot 2 Channel 0 Channel 1 Controller Channel 0 Channel 1 Slot 2 Slot 2 Slot 1 Slot 1 Slot 0 Slot 0 Figure 1 Layout of the Intel memory controllers and DIMM s The Xeon optimizes memory accesses by creating interleave sets across the memory controllers and/or memory channels. For example, if identical DIMMs are populated on both memory channels attached to a memory controller, the memory controller creates a 2-way interleave set across both DIMMs. Figure 2 on page 4 shows two such interleave sets. Copyright Lenovo All rights reserved. 3

4 Two-way interleaved set Two-way interleaved set Figure 2 Two-way interleave sets (four identical DIMMs) Interleaving enables higher memory bandwidth by spreading contiguous memory accesses across both memory channels rather than sending all memory accesses to one memory channel or the other. If DIMMS with different memory capacities are populated on the memory channels attached to a memory controller or if different numbers of identical capacity DIMMs are populated on the memory channels, the memory controller has to create multiple interleave sets. Managing multiple interleave sets creates overhead for the memory controller which can reduce memory bandwidth. Figure 2 illustrates a 2-way memory interleave set on an Intel E5 which results from populating identical memory DIMMs on each memory channel. These 2-way memory interleave sets can be further interleaved across the memory controllers. Consecutive addresses would alternate between the memory controllers with every fourth address going to each memory channel. Within a memory channel, a second level of interleaving called memory rank interleaving can occur. A memory rank is a block of data created from the memory chips on a memory DIMM. A memory rank is typically 64 bits wide. If ECC is supported, an additional 8 bits are added for a total of 72 bits. A DIMM may contain multiple memory ranks, for example, one, two and four ranks per DIMMs. rank interleaving is optimal when each DIMM on a memory channel has the same number of memory ranks. For example, each DIMM on a memory channel is a 2-rank DIMM. When installing memory DIMMs into your server, follow the DIMM installation sequence for your particular server. The configurations shown in this paper did not always follow the sequences for the servers they were implemented and measured on as a number of these configurations were put together just for demonstration purposes. Balanced memory configurations Balanced memory configurations enable optimal interleaving across all attached memory channels so memory bandwidth is maximized. Bandwidth can be optimized if both memory controllers on the same physical socket are identically configured. System level memory performance can be further optimized if each physical socket has the same physical memory capacity. 4 Maximizing System x and ThinkServer Performance with a Balanced Configuration

5 As a result, the basic guidelines for a balanced memory subsystem are as follows: 1. All populated memory channels should have the same total memory capacity and the same total number of ranks 2. All memory controllers on a socket should have the same configuration of memory DIMMs 3. All sockets on the same physical server should have the same configuration of memory DIMMs Tip: We refer to the above three bullets throughout this paper as the balanced memory guidelines 1, 2 and 3. About the STREAM test STREAM Triad is a simple, synthetic benchmark designed to measure sustainable memory bandwidth. Its intent is to measure the best memory bandwidth available. STREAM Triad will be used to measure the sustained memory bandwidth of various memory configurations to see the effect of unbalanced memory configurations on memory bandwidth. For more information about STREAM Triad, see: topology In this paper we are testing with a server that has an E v3 with two memory controllers, however the results equally apply to servers with E v4 s. Low-end s: Intel v3 s with fewer than 10 cores and E5 v4 s with fewer than 12 cores only have one memory controller in the package, with all four memory channels connected to the one memory controller. As a result, balanced memory guideline 2 does not apply for s with only one memory controller. To illustrate various memory topologies for a with two memory controllers, different memory configurations will be designated as A:B:C:D where each letter indicates the number of DIMMs populated on each memory channel. A refers to Channel 0 on B refers to Channel 1 on C refers to Channel 0 on D refers to Channel 1 on This designation is shown in Figure 3 on page 6. 5

6 A B Channel 0 Channel 1 Channel 0 Channel 1 C D Figure 3 Channel designation As an example, a 3:2:1:0 memory configuration has: 3 DIMMs on Channel 0 on 2 DIMMs on Channel 1 on 1 DIMM on Channel 0 on 0 DIMMs on Channel 1 on Applying the balanced memory guidelines - E5 s We will start with the assumption that balanced memory guideline 3 described in Balanced memory configurations on page 4 is followed so that all sockets on the same physical server have the same configuration of memory DIMMs. Configuration of 4 DIMMs - balanced Therefore, we only have to look at one socket for each memory configuration. We will start with one DIMM in each memory channel which yields the 1:1:1:1 memory configuration shown in Figure 4. Figure 4 One memory DIMM in each channel (STREAM Triad relative memory bandwidth = 100) This is a balanced memory configuration as it follows balanced memory guideline 1 with all memory channels having of memory capacity and two ranks total. It also follows balanced memory guideline 2 with both memory controllers having the same configuration of DIMMs. Interleaving can be done across the memory controllers and across both pairs of memory channels. The 1:1:1:1 memory configuration provides a maximum amount of memory bandwidth with a relative STREAM Triad score of Maximizing System x and ThinkServer Performance with a Balanced Configuration

7 Configuration of 5 DIMMs - unbalanced Next we will add one DIMM to see its effect on memory bandwidth. This 2:1:1:1 memory configuration is shown in Figure 5. Figure 5 2:1:1:1 memory configuration (STREAM Triad relative memory bandwidth = 26) This is not a balanced memory configuration as it breaks both balanced memory guideline 1 with a different memory capacity and number of ranks on one memory channel than the others and balanced memory guideline 2 with different DIMM configurations on each memory controller. While a 2-way interleave set is created on, has to create two separate interleave sets for the three DIMMs on its two memory channels: A 2-way interleave set is created using one DIMM from each memory channel. A 1-way interleave set is created using the remaining DIMM on Channel 0. Interleaving across the memory controllers is not done for this configuration due to the unbalanced memory between them. The inability to interleave across the memory controllers combined with the interleaving overhead on Channel 0 reduces the relative memory bandwidth of the 2:1:1:1 memory configuration to 26 or 26% of the 1:1:1:1 memory configuration. Configurations of 6 DIMMs - 3 unbalanced and 1 balanced There are numerous ways to populate six DIMMs in the twelve DIMM s. We will look at four different ways to see the effect on memory bandwidth. The first is the 2:1:1:2 memory configuration shown in Figure 6. Figure 6 2:1:1:2 memory configuration (STREAM Triad relative memory bandwidth = 52) This is an unbalanced memory configuration as it does not follow balanced memory guideline 1 with two memory channels having 32 GB of memory and four total ranks while the other two have only 16GB of memory and two ranks. Balanced memory guideline 2 is followed as both memory controllers have the same configuration of memory DIMMs allowing interleaving to be done across the memory controllers. 7

8 Each memory controller has to create two separate interleave sets for the three DIMMs on their two memory channels as described above for in the 2:1:1:1 memory configuration. Even though balanced memory guideline 2 is followed with each memory controller having the same configuration of DIMMs, the interleaving overhead of multiple sets on the channels reduces the relative memory bandwidth of the 2:1:1:2 memory configuration to only 52. Another way to populate memory with six DIMMs is in a 3:1:1:1 configuration as shown in Figure 7 on page 8. Figure 7 3:1:1:1 memory configuration (STREAM Triad relative memory bandwidth = 20) This unbalanced memory configuration does not follow balanced memory guideline 1 as one channel has more memory capacity and ranks than the others. It also does not follow balanced memory guideline 2 as the memory controllers do not have the same DIMM configurations. Interleaving cannot be done across the memory controllers. can interleave its memory channels as they follow balanced memory guideline 1. will need to create a 2-way interleave set across its memory channels and two 1-way interleave sets for the two other DIMMs on its Channel 0. Since most of this configuration s memory is on, this interleaving overhead is very detrimental. The result is a relative memory bandwidth of 20. One way to fulfill balanced memory guideline 2 with six DIMMs is with a 3:0:3:0 memory configuration shown in Figure 8. Figure 8 3:0:3:0 memory configuration (STREAM Triad relative memory bandwidth = 39) This memory configuration also follows balanced memory guideline 1 and is a balanced memory configuration. Even so, all memory channels should be populated to achieve maximum memory bandwidth. Interleaving is done across the memory controllers. Each memory controller will create three 1-way interleave sets on Channel 0. Even though balanced memory guideline 2 is met, this memory configuration produces a relative memory bandwidth of 39 mostly due to no contribution from either Channel 1. 8 Maximizing System x and ThinkServer Performance with a Balanced Configuration

9 The final way to arrange six DIMMs is to put all of them on one memory controller in the 3:3:0:0 memory configuration shown in Figure 9 on page 9. Figure 9 3:3:0:0 memory configuration (STREAM Triad relative memory bandwidth = 38) This memory configuration does not follow balanced memory guideline 1 in the same way as the 3:0:3:0 memory configuration. It also does not follow balanced memory guideline 2 as all the memory is on one memory controller. Having one memory controller unpopulated entirely removes its contribution to memory bandwidth. Interleaving can occur between the channels on. Even so, the 3:3:0:0 memory configuration has a relative memory bandwidth of 38. Configurations of 8 DIMMs - balanced Using eight DIMMs, it is easy to create the balanced 2:2:2:2 memory configuration as shown in Figure 10. Figure 10 2:2:2:2 memory configuration (STREAM Triad relative memory bandwidth = 100) This memory configuration fulfills balanced memory guideline 1 with all channels populated equally and balanced memory guideline 2 with each memory controller having the same DIMM configuration. This memory configuration can interleave between both the memory controllers and the memory channels. The 2:2:2:2 memory configuration provides the maximum relative memory bandwidth of 100. Configurations of 8 DIMMs - unbalanced The same eight memory DIMMs can also be arranged in the unbalanced memory configuration of 3:1:1:3 as shown in Figure 11 on page 10. 9

10 Figure 11 3:1:1:3 memory configuration (STREAM Triad relative memory bandwidth = 53) This configuration does not follow balanced memory guideline 1 as half the memory channels have 48 GB of memory and 6 total ranks, while the other memory channels have only of memory and 2 ranks. This memory configuration can be interleaved across the memory controllers but not efficiently across the memory channels. Each memory controller will have one 2-way interleave set and two 1-way interleave sets. This limits its relative memory bandwidth to 53. Configurations of 3 DIMMs - unbalanced One other memory configuration to look at is having only three memory DIMMs in the 1:1:1:0 memory configuration shown in Figure 12. Figure 12 1:1:1:0 memory configuration (STREAM Triad relative memory bandwidth = 60) This unbalanced memory configuration does not follow balanced memory guideline 1 with one unpopulated memory channel nor balanced memory guideline 2 with two DIMMs on one memory controller and only one on the other. This memory configuration cannot be interleaved efficiently across the memory controllers nor at all across the memory channels of. It can be interleaved across the memory channels of. It also suffers from lacking any contribution to memory bandwidth from Channel 1 on as it is unpopulated. The result is a relative memory bandwidth of Maximizing System x and ThinkServer Performance with a Balanced Configuration

11 Applying the balanced memory guidelines - E7 s The Intel Xeon E7 uses a slightly different memory architecture to enable support of more DIMMs. Each has two integrated memory controllers, and each memory controller has two Scalable Interconnect generation 2 (SMI2) links that are connected to two scalable memory buffers. Each memory buffer has two memory channels, and each channel supports three DIMMs, for a total of 24 DIMMs per. The use of memory buffers doubles the number of memory channels and DIMMs supported per. The E7 memory architecture is shown in Figure 13 on page 11. Slot 0 Slot 1 Slot 2 Slot 0 Slot 1 Slot 2 Slot 0 Slot 1 Slot 2 Slot 0 Slot 1 Slot 2 Buffer 0 Buffer 1 Xeon E7 Buffer 2 Buffer 3 Slot 2 Slot 2 Slot 2 Slot 2 Slot 1 Slot 1 Slot 1 Slot 1 Slot 0 Slot 0 Slot 0 Slot 0 Figure 13 Intel Xeon E7 memory DIMM layout configurations will be designated as A:B:C:D:E:F:G:H where each letter indicates the number of DIMMs populated on each memory channel. A refers to Channel 0 on Buffer 0 on B refers to Channel 1 on Buffer 0 on C refers to Channel 0 on Buffer 1 on D refers to Channel 1 on Buffer 1 on E refers to Channel 0 on Buffer 2 on F refers to Channel 1 on Buffer 2 on G refers to Channel 0 on Buffer 3 on H refers to Channel 1 on Buffer 3 on This designation is shown in Figure 14 on page 11. A Channel 0 B Channel 1 C D Channel 0 Channel 1 Buffer 0 Buffer 1 Xeon E7 Buffer 2 Buffer 3 Channel 0 Channel 1 Channel 0 Channel 1 E F G H Figure 14 Channel designation for E7 s 11

12 The memory buffers provide another level that can be interleaved. Balanced memory guideline 2 now equally applies to memory buffers as it does to memory controllers in that all memory buffers on a socket should have the same configuration of DIMMs to provide for efficient interleaving across them. Configuration of 8 DIMMs - balanced The first memory configuration we will look at is a balanced 1:1:1:1:1:1:1:1 memory configuration with one DIMM on each memory channel as shown in Figure 15. This memory configuration follows all the balanced memory guidelines and can be interleaved efficiently across the memory controllers, memory buffers, and memory channels. It provides the maximum relative memory bandwidth of 100. MB0 MB1 Xeon E7 MB2 MB3 Figure 15 1:1:1:1:1:1:1:1 memory configuration (STREAM Triad relative memory bandwidth = 100) Configuration of 9 DIMMs - unbalanced Adding one additional memory DIMM produces the unbalanced 2:1:1:1:1:1:1:1 memory configuration shown in Figure 16 on page 12. MB0 MB1 Xeon E7 MB2 MB3 Figure 16 2:1:1:1:1:1:1:1 memory configuration (STREAM Triad relative memory bandwidth = 16) This configuration does not follow balanced memory guideline 1 with one memory channel having twice the memory capacity and ranks of all the others. It also does not follow balanced memory guideline 2 with different memory DIMM configurations on the memory controllers, but it is balanced across the memory buffers on. Efficient interleaving occurs between Buffer 2 and Buffer 3 as they both have the same configurations of DIMMs attached to them. 12 Maximizing System x and ThinkServer Performance with a Balanced Configuration

13 It is difficult to create balances with an odd number of DIMMs. The result is a very poor relative memory bandwidth of 16. Configuration of 10 DIMMs - unbalanced Adding one more DIMM produces the unbalanced 2:1:1:1:2:1:1:1 memory configuration shown in Figure 17. MB0 MB1 Xeon E7 MB2 MB3 Figure 17 2:1:1:1:2:1:1:1 memory configuration (STREAM Triad relative memory bandwidth = 48) This configuration does follow balanced memory guideline 2 with both memory controllers having the same DIMM configurations allowing interleaving across the memory controllers. This balanced memory guideline is not followed for the memory buffers. Balanced memory guideline 1 is not followed as two memory channels have twice the memory capacity and ranks as the other six. Buffers 1 and 3 do follow balanced memory guideline 1 allowing efficient interleaving to be done across their memory channels. The result is a relative memory bandwidth of 48. Configuration of 12 DIMMs - unbalanced Adding two more DIMMs produces the unbalanced 2:1:2:1:2:1:2:1 memory configuration shown in Figure 18 on page 13. MB0 MB1 Xeon E7 MB2 MB3 Figure 18 2:1:2:1:2:1:2:1 memory configuration (STREAM Triad relative memory bandwidth = 64) Balanced memory guideline 2 is followed for both memory controllers and all memory buffers with matching DIMM configurations. This allows for interleaving between all of them. Unfortunately, balanced memory guideline 1 is not followed as half the memory channels have twice the memory capacity and ranks as the other half. The result is less efficient 13

14 interleaving across the channels of each memory buffer and a relative memory bandwidth of 64. Configuration of 14 DIMMs - unbalanced Using 14 DIMMs produces the unbalanced 2:1:2:2:2:1:2:2 memory configuration shown in Figure 19. MB0 MB1 Xeon E7 MB2 MB3 Figure 19 2:1:2:2:2:1:2:2 memory configuration (STREAM Triad relative memory bandwidth = 33) This configuration follows balanced memory guideline 2 with both memory controllers having the same DIMM configurations. This allows for efficient interleaving across the memory controllers. The memory buffers do not follow balanced memory guideline 2 as half have three DIMMs and half have four. Balanced memory guideline 1 is not followed as not all memory channels have the same memory capacity and ranks. Pairs of memory buffers do have the same DIMM configurations: Buffers 0 and 2 and Buffers 1 and 3. Interleaving can be done efficiently between these memory buffer pairs. The result is a relative memory bandwidth of 33. Configuration of 16 DIMMs - balanced Adding two more DIMMs produces the balanced 2:2:2:2:2:2:2:2 memory configuration shown in Figure 20. MB0 MB1 Xeon E7 MB2 MB3 Figure 20 2:2:2:2:2:2:2:2 memory configuration (STREAM Triad relative memory bandwidth = 100) This follows balanced memory guideline 1 as all memory channels have the same memory capacity and total ranks. It also follows balanced memory guideline 2 as both memory 14 Maximizing System x and ThinkServer Performance with a Balanced Configuration

15 controllers and all memory buffers have the same DIMM configurations. This allows for efficient interleaving at all levels and provides a relative memory bandwidth of 100. Maximizing memory bandwidth In order to maximize the memory bandwidth of a server, the following rules should be followed: Balance the memory across the sockets - all sockets on the same physical server should have the same configuration of memory DIMMs Balance the memory across the memory controllers - all memory controllers on a socket should have the same configuration of memory DIMMs Balance the memory across the memory channels - all memory channels should be populated and have the same total memory capacity and the same total number of ranks If a server requires a specific memory capacity, sometimes smaller DIMMs or a mix of DIMM sizes are needed to produce a balanced memory configuration. For example, you may require 96 GB of memory on a server with one Intel. This can be accomplished using six DIMMs. Unfortunately there is no way to follow all the rules above with six DIMMs on four memory channels. Options in this situation are: Use twelve 8 GB DIMMs. These would be arranged as a 3:3:3:3 configuration which does follow all the rules. Use one DIMM and one 8 GB DIMM on each channel. Have more memory than required to produce a balanced memory configuration. In this case, eight can be arranged as a 2:2:2:2 balanced memory configuration. The important thing is to create a balanced memory configuration following all the above rules to maximize memory bandwidth and overall server performance. Cluster on Die option impact on memory bandwidth Cluster on Die is a parameter that is set in UEFI and effectively splits a into two parts so that it acts like two s. The CoD option is only available on Intel Xeon E v3 and Intel E v4 s with two memory controllers - Intel v3 s with 10 or more cores and E5 v4 s with 12 or more cores. Configurations with the CoD option can improve performance in workloads that are highly Non-Uniform Access (NUMA) optimized. Each half of the is treated as a separate NUMA node with ownership of half of the cores, a memory controller, and locally attached memory. Such a configuration can improve performance for workloads whose data is found almost entirely within the cluster it is running on. Figure 21 on page 16 shows an Intel E5 with the CoD option producing two clusters. 15

16 Cluster 0 Cluster 1 Figure 21 2:2:1:1 memory configuration with Cluster on Die making two clusters (STREAM = 100) The CoD option can reduce the impact of not following balanced memory guideline 2. More memory capacity can be attached to one memory controller than the other and still produce maximum memory bandwidth as long as memory is balanced across the memory channels of each memory controller. Without the CoD option, balanced memory guideline 2 is not followed in the 2:2:1:1 configuration making it an unbalanced memory configuration with reduced memory bandwidth. With the CoD option, the 2:2:1:1 configuration provides maximum memory bandwidth. Even so, it is recommended that all the balanced memory guidelines be followed even with configurations with the CoD option. Summary Overall server performance is affected by the memory subsystem which can provide both high memory bandwidth and low memory access latency when properly configured. Balancing memory across the memory controllers and the memory channels produces memory configurations which can efficiently interleave memory references among its DIMMs producing the highest possible memory bandwidth. An unbalanced memory configuration can reduce the total memory bandwidth to as low as 16% that of a balanced memory configuration. Implementing all three of the balanced memory guidelines described in this paper results in balanced memory configurations producing the best possible memory bandwidth and overall performance. Change history October 2017: Correction that one of the 6-DIMM configurations is balanced April 2016 Initial publication 16 Maximizing System x and ThinkServer Performance with a Balanced Configuration

17 Authors This paper was produced by the following team of specialists: Dan Colglazier is a Senior Engineer in the Lenovo Data Center Performance Group in Morrisville, NC. He had previously spent over 30 years at IBM, where he started out in the IBM Data Processing Division performance team helping improve the designs of future mainframe storage hierarchies. Assessing the performance of future System x servers in both IBM and Lenovo has been his main focus. He is currently the leader of the Performance Design Guidance team. Dan holds a Bachelor of Science degree in Computer Engineering and a Master of Science degree in Electrical Engineering both from the University of Illinois. Joe Jakubowski is a Senior Technical Staff Member in the Lenovo Server Performance Laboratory in Morrisville, NC. Previously, he spent 30 years at IBM. He started his career in the IBM Networking Hardware Division test organization and worked on various Token Ring adapters, switches and test tool development projects. He has spent the past 21 years in the server performance organization focusing primarily on database, virtualization and new technology performance. His current role includes all aspects of x86 server architecture and performance. Joe holds Bachelor of Science degrees in Electrical Engineering and Engineering Operations from North Carolina State University and a Master of Science degree in Telecommunications from Pace University. Tristian "Truth" Brown is a Hardware Performance Engineer on the Lenovo Server Performance Team in Raleigh, NC. He is responsible for the hardware analysis of high-performance, flash-based storage solutions for System x servers. Truth earned a bachelor's degree in Electrical Engineer from Tennessee State University and a master's degree in Electrical Engineering from North Carolina State University. His focus areas were in Computer Architecture and System-on-Chip (SoC) micro design and validation. Thanks to the following people for their contributions to this project: Charles Stephan, Lenovo Server Performance Team David Watts, Lenovo Press 17

18 Notices Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: Lenovo (United States), Inc Think Place - Building One Morrisville, NC U.S.A. Attention: Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this publication to non-lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Copyright Lenovo All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by Global Services Administration (GSA) ADP Schedule Contract 18

19 This document was created or updated on October 4, Send us your comments via the Rate & Provide Feedback form found at Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol ( or ), indicating US registered or common law trademarks owned by Lenovo at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of Lenovo trademarks is available on the Web at The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo Lenovo(logo) System x The following terms are trademarks of other companies: Intel, Xeon, and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Other company, product, or service names may be trademarks or service marks of others. 19

Intel Xeon Scalable Family Balanced Memory Configurations

Intel Xeon Scalable Family Balanced Memory Configurations Front cover Intel Xeon Scalable Family Balanced Memory Configurations Last Update: 20 November 2017 Demonstrates three balanced memory guidelines for Intel Xeon Scalable processors Compares the performance

More information

BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product)

BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product) BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product) BladeCenter HS21 XM Memory Configurations (withdrawn product) 1 Memory DIMM placement The logical memory DIMM configuration

More information

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers Front cover Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers Introduces the SSD Performance Accelerator for Lenovo servers Describes the performance gains from using MegaRAID

More information

Introduction to PCI Express Positioning Information

Introduction to PCI Express Positioning Information Introduction to PCI Express Positioning Information Main PCI Express is the latest development in PCI to support adapters and devices. The technology is aimed at multiple market segments, meaning that

More information

Introduction to Windows Server 2016 Hyper-V Discrete Device Assignment

Introduction to Windows Server 2016 Hyper-V Discrete Device Assignment Front cover Introduction to Windows Server 2016 Hyper-V Discrete Device Assignment Introduces the new PCIe Device Passthrough feature of Microsoft Windows Server 2016 Describes how to make PCIe devices

More information

Lenovo RAID Introduction Reference Information

Lenovo RAID Introduction Reference Information Lenovo RAID Introduction Reference Information Using a Redundant Array of Independent Disks (RAID) to store data remains one of the most common and cost-efficient methods to increase server's storage performance,

More information

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo Front cover Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo Introduces Read Intensive SSD Identification on Lenovo Storage V-series product family Highlights the tips

More information

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information Main Feature x440 server x445 server IBM chipset First generation XA-32 Second generation XA-32 SMP scalability Support

More information

OSIG Change History Article

OSIG Change History Article OSIG Change History Article Change history The OSIG has moved The OSIG is now available as a web application. See http://lenovopress.com/osig 21 September 2016 Windows Server 2016 is Certified on x3850

More information

Lenovo exflash DDR3 Storage DIMMs Product Guide

Lenovo exflash DDR3 Storage DIMMs Product Guide Lenovo exflash DDR3 Storage DIMMs Product Guide exflash memory-channel storage is the newest innovative flash memory technology from Lenovo, first introduced with System x3850 X6 and x3950 X6 servers.

More information

An Introduction to NIC Teaming with Lenovo Networking Switches

An Introduction to NIC Teaming with Lenovo Networking Switches Front cover An Introduction to NIC Teaming with Lenovo Networking Switches Shows how Network Interface Card (NIC) teaming can be configured Includes examples for Linux, Windows, and VMware Describes how

More information

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter Product Guide The Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter provide highperformance

More information

1 UPDATING GCM16, GCM32 (1754D1X, 1754D2X) FIRMWARE

1 UPDATING GCM16, GCM32 (1754D1X, 1754D2X) FIRMWARE Contents 1 UPDATING GCM16, GCM32 (1754D1X, 1754D2X) FIRMWARE... 1 2 CHANGE HISTORY FOR EMERSON_FW_GCM16_GCM32_V1.26.1.23978... 2 2.1 ENHANCEMENTS... 2 2.2 PROBLEMS FIXED... 3 3 UPDATE PROCEDURE... 4 3.1

More information

2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide

2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide 2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide The IBM 2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter is the perfect example of IBM's goal to meet user requirements

More information

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide Flex System FC3172 2-port 8Gb FC Adapter Lenovo Press Product Guide The Flex System FC3172 2-port 8Gb FC Adapter enables high-speed access for Flex System compute nodes to connect to a Fibre Channel storage

More information

Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide

Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide IBM is committed to offering both function and flexibility to our clients through our products.

More information

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide The N2225 and N2226 SAS/SATA HBAs for System x are low-cost, high-performance host bus adapters for high-performance connectivity between

More information

ServeRAID C100 and C105 Product Guide

ServeRAID C100 and C105 Product Guide ServeRAID C100 and C105 Product Guide The ServeRAID C100 and ServeRAID C105 are integrated SATA controllers with software RAID capabilities. They are a cost-effective way to provide reliability, performance,

More information

Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide

Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide The Brocade 10Gb CNA for IBM System x is a PCI Express 2.0 x8 10Gb Converged Network Adapter with two SFP+ cages. The adapter can support either

More information

IBM High IOPS MLC Adapters Product Guide

IBM High IOPS MLC Adapters Product Guide IBM High IOPS MLC Adapters Product Guide The IBM 365GB, 785GB and 1.2TB MLC Mono and 2.4TB MLC Duo High IOPS Adapters for IBM System x, IBM BladeCenter, and IBM Flex System are second-generation adapters

More information

IBM High IOPS Modular Adapters (Withdrawn) Product Guide

IBM High IOPS Modular Adapters (Withdrawn) Product Guide IBM High IOPS Modular Adapters (Withdrawn) Product Guide The new family of IBM High IOPS Modular Adapters is the ultimate performance solution for embedded direct-attached storage for IBM System x, IBM

More information

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter Brocade 20-port 8Gb SAN Switch Modules for BladeCenter Product Guide The Brocade Enterprise 20-port, 20-port, and 10-port 8 Gb SAN Switch Modules for BladeCenter deliver embedded Fibre Channel switching

More information

Flex System EN port 10Gb Ethernet Adapter Product Guide

Flex System EN port 10Gb Ethernet Adapter Product Guide Flex System EN4132 2-port 10Gb Ethernet Adapter Product Guide The Flex System EN4132 2-port 10Gb Ethernet Adapter delivers high-bandwidth and industry-leading Ethernet connectivity for performance-driven

More information

IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide

IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide The family of IBM rack-based local console switches is designed to provide exceptional scalability and flexibility in managing data

More information

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide SAS 2.5-inch Hybrid Hard Drives for System x Product Guide The IBM SAS 2.5-inch Hybrid hard disk drives (HDDs) for System x provide cost-effective performance and density by combining a cache of NAND flash

More information

Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide

Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide The Half-High LTO Generation 6 (LTO6) SAS Tape Drive is a high-performance, high-capacity data-storage device that is designed to back

More information

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology

More information

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide Flex System FC5022 2-port 16Gb FC Adapter Lenovo Press Product Guide The network architecture on the Flex System platform has been specifically designed to address network challenges, giving you a very

More information

Flex System EN port 1Gb Ethernet Adapter Product Guide

Flex System EN port 1Gb Ethernet Adapter Product Guide Flex System EN202 -port 1Gb Ethernet Adapter Product Guide The Flex System EN202 -port 1Gb Ethernet Adapter is a quad-port Gigabit Ethernet network adapter. When it is combined with the Flex System EN2092

More information

Lenovo 42U 1200mm Deep Racks Product Guide

Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200 mm Deep Static and Dynamic Rack offerings are industry-standard 19-inch server cabinets that are designed for high availability server environments.

More information

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide The IBM System Storage N series Reference Architecture provides deployment

More information

Introduction to Windows Server 2016 Nano Server

Introduction to Windows Server 2016 Nano Server Front cover Introduction to Windows Server 2016 Nano Server Introduces this new feature of Microsoft Windows Server 2016 Describes how to create and manage these low-footprint servers Explains how to implement

More information

Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide

Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide The Broadcom NetXtreme Gigabit Ethernet Adapters are a family of high performance PCI Express adapters. The adapters are available with either

More information

Platform LSF Version 9 Release 1.1. Migrating on Windows SC

Platform LSF Version 9 Release 1.1. Migrating on Windows SC Platform LSF Version 9 Release 1.1 Migrating on Windows SC27-5317-00 Platform LSF Version 9 Release 1.1 Migrating on Windows SC27-5317-00 Note Before using this information and the product it supports,

More information

Lenovo RDX USB 3.0 Disk Backup Solution Product Guide

Lenovo RDX USB 3.0 Disk Backup Solution Product Guide Lenovo RDX USB 3.0 Disk Backup Solution Product Guide The new Lenovo Removable Disk EXchange (RDX) USB 3.0 removable disk backup solution for System x and ThinkServer is designed to address your increasing

More information

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide The network architecture on the Flex System platform is designed to address network challenges, giving you a scalable way to integrate,

More information

Platform LSF Version 9 Release 1.3. Migrating on Windows SC

Platform LSF Version 9 Release 1.3. Migrating on Windows SC Platform LSF Version 9 Release 1.3 Migrating on Windows SC27-5317-03 Platform LSF Version 9 Release 1.3 Migrating on Windows SC27-5317-03 Note Before using this information and the product it supports,

More information

Build integration overview: Rational Team Concert and IBM UrbanCode Deploy

Build integration overview: Rational Team Concert and IBM UrbanCode Deploy Highlights Overview topology of the main build-related interactions between the IBM UrbanCode Deploy and Rational Team Concert servers. Overview of two common build and deployment processes for mainframe

More information

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide The ServeRAID-MR10i SAS/SATA Controller is a low-cost PCI Express RAID controller for Internal System RAID 0, 1, 10, 5, 50, 6, and 60.

More information

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide Designed for organizations that run online transaction processing (OLTP) applications, the IBM DB2 purescale Feature

More information

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for System x are the next-generation 6 Gbps SAS 2.0 RAID controllers. The adapters

More information

ServeRAID H1110 SAS/SATA Controller Product Guide

ServeRAID H1110 SAS/SATA Controller Product Guide ServeRAID H1110 SAS/SATA Controller Product Guide The ServeRAID H1110 SAS/SATA Controller for System x offers a low-cost enterprise-grade RAID solution for internal HDDs and integrates popular SAS technology

More information

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide Streamlined installation and management, plus unrivaled scalability and industry-leading virtualization

More information

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460 Hardware Replacement Guide Lenovo 3000 J Series Types 8453, 8454, 8455, 8458, 8459, 8460 Lenovo 3000 J Series First Edition (December 2005) Copyright Lenovo 2005. Portions Copyright International Business

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

Lenovo PM963 NVMe Enterprise Value PCIe SSDs Product Guide

Lenovo PM963 NVMe Enterprise Value PCIe SSDs Product Guide Lenovo PM963 NVMe Enterprise Value PCIe SSDs Product Guide The Lenovo PM963 NVMe Enterprise Value PCIe solid-state drives (SSDs) in capacities of 1.92 TB and 3.84 TB are general-purpose yet high-performance

More information

IBM PowerKVM available with the Linux only scale-out servers IBM Redbooks Solution Guide

IBM PowerKVM available with the Linux only scale-out servers IBM Redbooks Solution Guide IBM PowerKVM available with the Linux only scale-out servers IBM Redbooks Solution Guide The IBM POWER8 processors are built for big data and open innovation. Now, Linux administrators and users can maximize

More information

Release Notes. IBM Tivoli Identity Manager Rational ClearQuest Adapter for TDI 7.0. Version First Edition (January 15, 2011)

Release Notes. IBM Tivoli Identity Manager Rational ClearQuest Adapter for TDI 7.0. Version First Edition (January 15, 2011) IBM Tivoli Identity Manager for TDI 7.0 Version 5.1.1 First Edition (January 15, 2011) This edition applies to version 5.1 of Tivoli Identity Manager and to all subsequent releases and modifications until

More information

SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide

SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide The SATA 1.8-inch and 2.5-inch MLC Enterprise solid-state drives (SSDs) for System x employ enterprise MLC NAND technology to bring

More information

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide The ServeRAID M5000 Series Performance Accelerator Key for System x enables performance enhancements needed by emerging SSD

More information

Lenovo XClarity Provisioning Manager User Guide

Lenovo XClarity Provisioning Manager User Guide Lenovo XClarity Provisioning Manager User Guide Fifth Edition (October 2018) Copyright Lenovo 2017, 2018. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services

More information

IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide

IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide The new IBM RDX removable disk backup solution is designed to reliably and cost-effectively help protect your business's valuable assets.

More information

Introduction to Spine-Leaf Networking Designs

Introduction to Spine-Leaf Networking Designs Front cover Introduction to - Networking Designs Last Update: 7 November 2017 Explains three-tier versus spine-leaf network architectures Details the advantages and disadvantages of three-tier and spine-leaf

More information

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide The ServeRAID-BR10il SAS/SATA Controller v2 is an ideal solution for servers that need high-speed data transfer in

More information

Version 1.2 Tivoli Integrated Portal 2.2. Tivoli Integrated Portal Customization guide

Version 1.2 Tivoli Integrated Portal 2.2. Tivoli Integrated Portal Customization guide Version 1.2 Tivoli Integrated Portal 2.2 Tivoli Integrated Portal Customization guide Version 1.2 Tivoli Integrated Portal 2.2 Tivoli Integrated Portal Customization guide Note Before using this information

More information

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI IBM FlashSystem V9000 7.8.0 MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, 9846-92F, 9848-92F Quick Start Guide IBM GI13-2894-06 Edition notice This edition applies to IBM FlashSystem V9000 7.8.0 and to all

More information

Best practices. Linux system tuning for heavilyloaded. IBM Platform Symphony

Best practices. Linux system tuning for heavilyloaded. IBM Platform Symphony IBM Platform Symphony Best practices Linux system tuning for heavilyloaded hosts Le Yao IBM Systems & Technology Group, Software Defined Systems Test Specialist: Custom Applications Issued: November 2013

More information

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony IBM Platform Symphony Best practices Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster AjithShanmuganathan IBM Systems & Technology Group, Software Defined

More information

IBM. Networking INETD. IBM i. Version 7.2

IBM. Networking INETD. IBM i. Version 7.2 IBM IBM i Networking INETD Version 7.2 IBM IBM i Networking INETD Version 7.2 Note Before using this information and the product it supports, read the information in Notices on page 5. This document may

More information

IBM FlashSystem V Quick Start Guide IBM GI

IBM FlashSystem V Quick Start Guide IBM GI IBM FlashSystem V9000 7.7 Quick Start Guide IBM GI13-2894-04 Edition notice This edition applies to IBM FlashSystem V9000 7.7 and to all subsequent releases and modifications until otherwise indicated

More information

Flex System IB port FDR InfiniBand Adapter Lenovo Press Product Guide

Flex System IB port FDR InfiniBand Adapter Lenovo Press Product Guide Flex System IB6132 2-port FDR InfiniBand Adapter Lenovo Press Product Guide The Flex System IB6132 2-port FDR InfiniBand Adapter delivers low latency and high bandwidth for performance-driven server clustering

More information

IBM emessage Version 8.x and higher. Account Startup Overview

IBM emessage Version 8.x and higher.  Account Startup Overview IBM emessage Version 8.x and higher Email Account Startup Overview Note Before using this information and the product it supports, read the information in Notices on page 3. This edition applies to all

More information

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Overview IBM Easy Tier is a performance function that automatically and non-disruptively migrates frequently accessed

More information

IBM High IOPS SSD PCIe Adapters IBM System x at-a-glance guide

IBM High IOPS SSD PCIe Adapters IBM System x at-a-glance guide IBM High IOPS SSD PCIe Adapters IBM System x at-a-glance guide The IBM High IOPS SSD PCIe Adapters provide a new generation of ultra-high-performance storage based on solid state device technology for

More information

Getting Started with InfoSphere Streams Quick Start Edition (VMware)

Getting Started with InfoSphere Streams Quick Start Edition (VMware) IBM InfoSphere Streams Version 3.2 Getting Started with InfoSphere Streams Quick Start Edition (VMware) SC19-4180-00 IBM InfoSphere Streams Version 3.2 Getting Started with InfoSphere Streams Quick Start

More information

IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide

IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide The IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module serves as a switching and routing fabric for the IBM BladeCenter

More information

Version 9 Release 0. IBM i2 Analyst's Notebook Premium Configuration IBM

Version 9 Release 0. IBM i2 Analyst's Notebook Premium Configuration IBM Version 9 Release 0 IBM i2 Analyst's Notebook Premium Configuration IBM Note Before using this information and the product it supports, read the information in Notices on page 11. This edition applies

More information

Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide

Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide Securing sensitive client and company data is becoming an IT task of paramount importance. Often

More information

Lenovo XClarity Essentials UpdateXpress User Guide

Lenovo XClarity Essentials UpdateXpress User Guide Lenovo XClarity Essentials UpdateXpress User Guide Version 2.2.0 Note Before using this documentation and the products it supports, read the information in Appendix B Notices on page 19. This edition applies

More information

DS8880 High Performance Flash Enclosure Gen2

DS8880 High Performance Flash Enclosure Gen2 Front cover DS8880 High Performance Flash Enclosure Gen2 Michael Stenson Redpaper DS8880 High Performance Flash Enclosure Gen2 The DS8880 High Performance Flash Enclosure (HPFE) Gen2 is a 2U Redundant

More information

2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide

2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide 2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide The 2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter is a dual port InfiniBand Host

More information

Version 9 Release 0. IBM i2 Analyst's Notebook Configuration IBM

Version 9 Release 0. IBM i2 Analyst's Notebook Configuration IBM Version 9 Release 0 IBM i2 Analyst's Notebook Configuration IBM Note Before using this information and the product it supports, read the information in Notices on page 11. This edition applies to version

More information

IBM. IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns. Version 2 Release 1 BA

IBM. IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns. Version 2 Release 1 BA IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns Version 2 Release 1 IBM BA21-8475-00 Note Before using this information and the product it supports, read the information in Notices

More information

Networking Bootstrap Protocol

Networking Bootstrap Protocol System i Networking Bootstrap Protocol Version 5 Release 4 System i Networking Bootstrap Protocol Version 5 Release 4 Note Before using this information and the product it supports, read the information

More information

IBM Kenexa LCMS Premier on Cloud. Release Notes. Version 9.3

IBM Kenexa LCMS Premier on Cloud. Release Notes. Version 9.3 IBM Kenexa LCMS Premier on Cloud Release Notes Version 9.3 IBM Kenexa LCMS Premier on Cloud Release Notes Version 9.3 Note Before using this information and the product it supports, read the information

More information

IBM. Avoiding Inventory Synchronization Issues With UBA Technical Note

IBM. Avoiding Inventory Synchronization Issues With UBA Technical Note IBM Tivoli Netcool Performance Manager 1.4.3 Wireline Component Document Revision R2E1 Avoiding Inventory Synchronization Issues With UBA Technical Note IBM Note Before using this information and the product

More information

Release Notes. IBM Tivoli Identity Manager Universal Provisioning Adapter. Version First Edition (June 14, 2010)

Release Notes. IBM Tivoli Identity Manager Universal Provisioning Adapter. Version First Edition (June 14, 2010) IBM Tivoli Identity Manager Version 5.1.2 First Edition (June 14, 2010) This edition applies to version 5.1 of Tivoli Identity Manager and to all subsequent releases and modifications until otherwise indicated

More information

IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version Release Notes

IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version Release Notes IBM Storage Management Pack for Microsoft System Center Operations Manager (SCOM) Version 1.2.0 Release Notes First Edition (September 2012) This edition applies to version 1.2.0 of the IBM Storage Management

More information

Netcool/Impact Version Release Notes GI

Netcool/Impact Version Release Notes GI Netcool/Impact Version 6.1.0.1 Release Notes GI11-8131-03 Netcool/Impact Version 6.1.0.1 Release Notes GI11-8131-03 Note Before using this information and the product it supports, read the information

More information

Version 2 Release 1. IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns IBM BA

Version 2 Release 1. IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns IBM BA Version 2 Release 1 IBM i2 Enterprise Insight Analysis Understanding the Deployment Patterns IBM BA21-8475-00 Note Before using this information and the product it supports, read the information in Notices

More information

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide IBM Tivoli Storage Manager for Virtual Environments (referred to as

More information

Release Notes. IBM Security Identity Manager GroupWise Adapter. Version First Edition (September 13, 2013)

Release Notes. IBM Security Identity Manager GroupWise Adapter. Version First Edition (September 13, 2013) Release Notes IBM Security Identity Manager GroupWise Adapter Version 6.0.2 First Edition (September 13, 2013) This edition applies to version 6.0 of IBM Security Identity Manager and to all subsequent

More information

IBM License Metric Tool Enablement Guide

IBM License Metric Tool Enablement Guide IBM Spectrum Protect IBM License Metric Tool Enablement Guide Document version for the IBM Spectrum Protect Version 8.1 family of products Copyright International Business Machines Corporation 2016. US

More information

IBM Rational Synergy DCM-GUI

IBM Rational Synergy DCM-GUI IBM Rational Synergy DCM-GUI Release 7.2.1.1 IBM Rational Synergy - 1 - This edition applies to IBM Rational Synergy version 7.2.1.1, and to all subsequent releases and modifications until otherwise indicated

More information

Best practices. Reducing concurrent SIM connection requests to SSM for Windows IBM Platform Symphony

Best practices. Reducing concurrent SIM connection requests to SSM for Windows IBM Platform Symphony IBM Platform Symphony Best practices Reducing concurrent SIM connection requests to SSM for Windows 2008 Tao Tong IBM Systems & Technology Group, Software Defined Systems Manager, Platform Symphony QA,

More information

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215,

More information

White Paper: Configuring SSL Communication between IBM HTTP Server and the Tivoli Common Agent

White Paper: Configuring SSL Communication between IBM HTTP Server and the Tivoli Common Agent White Paper: Configuring SSL Communication between IBM HTTP Server and the Tivoli Common Agent IBM Tivoli Provisioning Manager Version 7.2.1 Document version 0.1 Lewis Lo IBM Tivoli Provisioning Manager,

More information

IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide

IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide IBM Flex System FC3172 2-port 8Gb FC Adapter IBM Redbooks Product Guide The IBM Flex System FC3172 2-port 8Gb FC Adapter enables high-speed access for IBM Flex System compute nodes to connect to a Fibre

More information

Solution Guide: Flex System Solution for Oracle RAC

Solution Guide: Flex System Solution for Oracle RAC Bryan Reese Ajay Dholakia Thomas Parker Solution Guide: Flex System Solution for Oracle RAC Solution Reference Number: BDARACFX043 Contents Solution Guide: Flex System Solution for Oracle RAC..............................

More information

Intel I350 Gigabit Ethernet Adapters Product Guide

Intel I350 Gigabit Ethernet Adapters Product Guide Intel I350 Gigabit Ethernet Adapters Product Guide Based on the Intel I350 Gigabit Ethernet adapters from Lenovo build on Intel's history of delivering Ethernet products with flexible design and robust

More information

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide Flex System FC5052 2-port and FC5054 4-port 16Gb FC Adapters Lenovo Press Product Guide The Flex System FC5052 2-port and FC5054 4-port 16Gb FC Adapters enable the highest FC speed access for Flex System

More information

M910q. User Guide and Hardware Maintenance Manual. Overview. Computer locks. Specifications. Replacing FRUs. Replacing CRUs.

M910q. User Guide and Hardware Maintenance Manual. Overview. Computer locks. Specifications. Replacing FRUs. Replacing CRUs. M90q User Guide and Hardware Maintenance Manual Machine Type (MT): 0MU, 0MV, 0MW, 0MX, 0QN Energy Star MT: 0MU, 0MV, 0MW, 0MX, 0QN Overview Computer locks Specifications Locations of indicators, connectors,

More information

Development tools System i5 Debugger

Development tools System i5 Debugger System i Development tools System i5 Debugger Version 6 Release 1 System i Development tools System i5 Debugger Version 6 Release 1 Note Before using this information and the product it supports, read

More information

Implementing Enhanced LDAP Security

Implementing Enhanced LDAP Security IBM FileNet Image Services Version 4.2 Implementing Enhanced LDAP Security SC19-3304-00 IBM FileNet Image Services Version 4.2 Implementing Enhanced LDAP Security SC19-3304-00 Note Before using this information

More information

IBM Storage Driver for OpenStack Version Installation Guide SC

IBM Storage Driver for OpenStack Version Installation Guide SC IBM Storage Driver for OpenStack Version 1.1.0 Installation Guide SC27-4233-00 Note Before using this document and the product it supports, read the information in Notices on page 9. Edition notice Publication

More information

S3500 SATA MLC Enterprise Value SSDs for System x Product Guide

S3500 SATA MLC Enterprise Value SSDs for System x Product Guide S3500 SATA MLC Enterprise Value SSDs for System x Product Guide The S3500 SATA MLC Enterprise Value solid-state drives (SSDs) for System x employ MLC NAND flash memory and a 6 Gbps SATA interface to provide

More information

Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx

Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx IBM AnyPlace Kiosk 4838 Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx GA27-4371-01 IBM AnyPlace Kiosk 4838 Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx

More information

IBM z/os Management Facility V2R1 Solution Guide IBM Redbooks Solution Guide

IBM z/os Management Facility V2R1 Solution Guide IBM Redbooks Solution Guide IBM z/os Management Facility V2R1 Solution Guide IBM Redbooks Solution Guide z/osmf is a product for IBM z/os that simplifies, optimizes, and modernizes the z/os system programmer experience. z/osmf delivers

More information

IBM Endpoint Manager Version 9.1. Patch Management for Ubuntu User's Guide

IBM Endpoint Manager Version 9.1. Patch Management for Ubuntu User's Guide IBM Endpoint Manager Version 9.1 Patch Management for Ubuntu User's Guide IBM Endpoint Manager Version 9.1 Patch Management for Ubuntu User's Guide Note Before using this information and the product it

More information

IBM Security QRadar Version Customizing the Right-Click Menu Technical Note

IBM Security QRadar Version Customizing the Right-Click Menu Technical Note IBM Security QRadar Version 7.2.0 Technical Note Note: Before using this information and the product that it supports, read the information in Notices and Trademarks on page 3. Copyright IBM Corp. 2012,

More information