KLIC-DI COMMERCIAL PRODUCT MANUAL INTERFACE KNX COMMERCIAL A/C UNIT ZN1CL-KLIC-DI. Edition 8 Version 1.6
|
|
- Howard Hines
- 6 years ago
- Views:
Transcription
1 PRODUCT MANUAL KLIC-DI COMMERCIAL INTERFACE KNX COMMERCIAL A/C UNIT ZN1CL-KLIC-DI Edition 8 Version 1.6
2 Index 1. Introduction Installation KLIC-DI Installation Elements Description Configuration Basic Control Advanced Functionalities Parameterization Default Configuration General Mode Fan speed Scenes Temperature Limitation Automatic switch off Errors management Initial configuration Annex I. Communication Objects Annex II. Correspondence Error Codes of A/C Units ZENNiO AVANCE Y TECNOLOGÍA 2
3 1. INTRODUCTION The KLIC-DI is an interface that allows a bidirectional communication between a KNX domotic system and the commercial series air-conditioning units. Due to this bidirectional communication, the air conditioning unit can be controlled in the same way that using an IR remote controller and the real status of the airconditioning unit is checked and sent to the KNX bus for its monitoring. Figure 1.1 KLIC-DI In case of using a wired remote control in the same communication bus of the unit, the KLIC-DI will communicate with this remote control acting one device as master control while the other device will act as slave control. It is important to verify that the KLIC-DI and the wired remote control are configured with different type of control. This way, the control acting as slave will update its status when the master orders it and will communicate its status changes when they are modified from the own slave control. Device Features: Small enclosure: 90 x 60 x 35 mm (2 DIN rail units) Designed to be installed inside distribution boxes or electrical mounting boxes. The device shall be installed outside the AC indoor unit. KLIC-DI provides bidirectional communication with industrial and commercial air conditioning units. ZENNiO AVANCE Y TECNOLOGÍA 3
4 Provides control over the basic features of the unit together with control and error management, both of the own A/C unit codes, as well as the ones that may occur during communication. LED indicators allow monitoring of the bidirectional traffic flow. Integrated KNX Bus Coupling Unit. CE Compliant ZENNiO AVANCE Y TECNOLOGÍA 4
5 2. INSTALLATION 2.1. KLIC-DI INSTALLATION The KLIC-DI installation is performed the same way that any other KNX device. We just need to connect the device to KNX bus through the specific KNX connector. On the other hand, this device is connected to the internal PCB of the A/C unit (P1/P2 connectors), using a 2-wire cable. If the wired remote control from is also used, it is necessary to make sure that the wired remote control is in mode slave if the KLIC-DI is configured as master control. And vice versa, if the KLIC-DI is configured as slave control, the wired remote control must be in master position. Once the device is provided with power supply from the bus, both, the physical address and the KLIC application program can be downloaded. This device does not need any external supply, since it just works with the power supply of KNX bus. Connections to A/C unit P1/P2 bus diagrams A/C UNIT Figure 2.1 Connecting KLIC-DI to P1/P2 bus ZENNiO AVANCE Y TECNOLOGÍA 5
6 WIRED REMOTE CONTROL A/C UNIT Figure 2.2 Connecting KLIC-DI to bus P1/P2 with wired remote control (slave mode) Diagrams Leyend A B C P1 - P2 KLIC DI Wired remote control A/C unit Bus connection 1-2 Zennio connection terminal * The wired remote control must operate in the opposite mode to KLIC-DI 2.2. ELEMENTS DESCRIPTION Prog: To set the device programming mode. When initially pushed, after Powering, secure mode is set. Led: Luminous signal which indicates the state of the device. Besides including the programming red LED (typical in any KNX device), the KLIC-DI incorporates two more LEDs, blue and green ones, in order to inform about the bidirectional communication between KNX and the A/C unit, resulting very useful in the installation process. We can know the meaning watching the color: Red: programming LED. If it is ON indicates Programming mode. LED blinkling every 0,5s, the device is set in Secure Mode. ZENNiO AVANCE Y TECNOLOGÍA 6
7 Green: failure in the KLIC-DI power supply (this happens when the KLIC-DI is not connected to the unit and/or when the unit is not connected to the power supply line). Blinking green: communication data from the unit device to KLIC-DI. Blinking blue: communication data from KLIC-DI to the unit Communication Cable: 2-wire cable, direct to PI/P2 connectors that can be found at the PCB of the internal unit, or in the wired remote control. Nº Description 1 KNX connector 2 Programming and checking LED 3 Programming button 4 2-wire communication terminal ZENNiO AVANCE Y TECNOLOGÍA 7
8 3. CONFIGURATION 3.1. BASIC CONTROL With KLIC-DI, the air conditioning unit can be monitored and controlled the same way it is done with the wired remote control provided with the air conditioning unit. By means of bus KNX, the following basic functionalities of the air conditioning system can be controlled: ON/OFF of the air conditioning unit. Setpoint Temperature. Between 16 and 32 ºC. Operating Mode: Auto, Heat, Dry, Fan and Cool. Fan Speed: 2 or 3 speed levels configuration. (Check out the available levels in the units) These functionalities have associated a machine status, which is periodically sent to KLIC-DI. When KLIC-DI receives a status different from the previous one from the machine, it updates the status of the corresponding parameter in the bus KNX ADVANCED FUNCTIONALITIES Besides the basic control over the air conditioning system, KLIC-DI offers other advanced functionalities that give an added value with regard to the wired remote control: Scenes Configuration: allows establishing a specific parameters combination for the air conditioning machine. Auto Switch Off: allows temporarily switching off the machine if a status change in the communication object associated to it, takes place. An example of this functionality could be the use of a window sensor, associated to the auto switch off, that allows switching off the machine if the window is opened. Temperature Limitation: Commercial units are limited in temperature (usually to the range ºC. Please verify the range for a particular model in the corresponding A/C unit manual). This KLIC functionality allows configuring custom temperature ranges for the modes Heat and Cool by means of the ETS in such a way that the setpoint temperature ZENNiO AVANCE Y TECNOLOGÍA 8
9 will remain in the range. In case of receiving a temperature command from the bus KNX with a value out of the configured limits, the temperature value sent to the machine will be the corresponding limit value. Indoor temperature and Reference temperature: Commercial A/C units have several temperature sensors for measuring the temperature in different internal points. The Indoor temperature is the measured internal value and it is used together with the Reference temperature for controlling the modes Auto-Cool and Auto-Heat of the air-conditioning machine. The Reference temperature is the real temperature in the room to acclimatize. It is necessary to communicate this parameter to the machine by means of the corresponding communication object and it is hardly recommended to link this communication object with a temperature sensor (installed in the room) which periodically updates the temperature value. The modes Auto-Heat and Auto-Cool can be controlled in three different ways by the A/C unit: 1. The unit receives the Reference temperature and, according to a preconfigured hysteresis by the installer, it establishes the corresponding auto mode. 2. The machine uses the Indoor temperature and, according to a preconfigured hysteresis by the installer, it establishes the corresponding auto mode. 3. The machine establishes the auto mode according to the average value of the Reference temperature and the Indoor temperature. The temperature value used by the machine in order to switch beetween the Modes Auto-Cool and Auto-Cool depends on the configuration established in the A/C unit installation. This value, in any of the previous cases is compared to the setpoint temperature in such a way that if the setpoint temperature is higher the Auto-Heat mode is established and if the setpoint temperature is lower than this value, the Auto-Cool is established. Take into account: It is hardly recommended to link the Reference temperature to a temperature sensor that periodically monitors the real temperature in the room because the way of switching between the different Auto modes might not be known and this fact can lead to a wrong functioning of the Auto mode. The Reference temperature has a default value equal to 25ºC. ZENNiO AVANCE Y TECNOLOGÍA 9
10 Errors Management: this functionality allows the sending of messages to the bus informing about errors. Errors management handles the A/C unit error codes as well as any communication errors that may arise Besides informing about the apparition of possible errors it can be also configured the sending of the error type. In case of internal errors, the numerical code associated to the error type is shown in the following table: Error Number Type of Internal Error 1 Problems with the data reception (speed, parity, etc.) 2 Communication waiting time exceeded (Time-out) 3 Incorrect checksum 4 Incorrect response from the machine Regarding the numerical code associated to the external errors type, look up the manual of the installed air-conditioning system or the Annex II Correspondence Error Codes of the A/C units Initial Configuration: All machine status must have an initial value after installing the system or a power failure. With this purpose, it has been included in the KLIC the possibility of defining the initial status for the ON/OFF, temperature, fan and speed of the machine. These initial values can be sent both to the bus KNX and the air conditioning unit. Type of Control: Master/Slave It is important to take into account the type of control, master or slave, with which the KLIC-DI is going to be configured. The remote control master in the installation is in charge of the communication with the machine and it will retransmit the instructions and status between the machine and the slave remote control in case of having one. In spite of the master/salve configuration, all the functionalities can be set from both remote controls. ZENNiO AVANCE Y TECNOLOGÍA 1 0
11 This functionality allows including both the KLIC-DI and the wired remote control in the installation and choosing the desired master/slave configuration whenever the KLIC-DI and the wired control are not configured with the same type of control. In case of having both controls configured as masters, the display of the wired remote control will show the error 88 and the error U5 will be sent to the bus. Take into account: When switching the type of control of the wired control between master and slave, it is necessary to remove the power supply from the wired control and connecting it again for rebooting the wired control in the suitable mode Important: The wired control BRC1E51A7 can only operate as master control. In case of using this model of wired control in the installation, it is necessary to configurate the KLIC-DI as slave control. Logical Functions KLIC-DI for commercial units includes a logical functions module similar to the one of other Zennio actuators. Up to 5 logical functions can be implemented and each function can be made of 4 operations. The user can read the Logial Functions section of the manual of any Zennio actuator (MAX6, QUATRO or Classic-Hybrid) in order to get more detailed information about them. ZENNiO AVANCE Y TECNOLOGÍA 1 1
12 4. PARAMETERIZATION For starting to parameterize the device it is necessary to import the data base of the product KLIC-DI 1.6.vd2, once the ETS has been opened. Then the KLIC is added to the project where it is desired to include the device. Click with the right mouse button on the device and select Edit Parameters for starting with the configuration. In the following sections there is a detailed explanation about each of the different functionalities of the device in ETS DEFAULT CONFIGURATION This section shows the default configuration from which the device configuration starts. If the window Edit Parameters is opened for the first time, the KLIC General configuration by default will be found. Next figure shows the General window with the default values: Figure 4.1 Default General Configuration ZENNiO AVANCE Y TECNOLOGÍA 1 2
13 As we can see in the previous figure all the advanced functionalities: scenes, temperature limitation, auto switch off, errors management and initial configuration are disabled by default. If the Mode and Fan are selected, it will be seen that both the Individual Modes and the Simplified Modes (Cool/Heat) are disabled by default while the Fan is configured for 2 different fan speeds and the step control is also disabled. Figure 4.2 Default Mode Configuration Figure 4.3 Default Fan Configuration In the next figure, the available communication objects by default are shown: they allow sending the ON/OFF to the Split, setpoint temperature, mode and fan speed (two speeds), as well as receiving the status of these variables from the Split. Figure 4.4 Default Communication Objects ZENNiO AVANCE Y TECNOLOGÍA 1 3
14 4.2. GENERAL From the parameterization window General the advanced functionalities can be enabled: Scenes Temperature Limitation Auto OFF Errors Management Type of Control Indoor Temperature Sending Time Initial Configuration Logical Functions As we select the functionalities in the pull down lists, the access to the functionality configuration window will appear in the Menu at the left and the corresponding communication objects are enabled. This window also allows configuring the type of control for the remote control: Master/Slave And the Sending Time for the Indoor Temperature. This temperature is sent by the machine when the indoor temperature changes. In order to avoid an excessive sending of telegrams with this temperature, it has been implemented this parameter. This way, the indoor temperature will be sent every certain period of time specified with this parameter and only if the temperature has changed MODE As it has been previously seen in the default configuration, the specific Mode window allows the user select: Individual Modes When selecting the Individual Modes, two 1-bit communication objects will be enabled, one for controlling the mode and another one for receiving the status from the split, for each mode (Auto, Cool, Only Fan, Heat and Dry) besides the 1-byte communication objects for controlling and indicating the Mode that exist by default. ZENNiO AVANCE Y TECNOLOGÍA 1 4
15 If the option Individual Modes is activated, the operating mode of the machine will be sent by means of the 1-bit Sending object associated to the mode. Moreover the Mode will be also sent to the bus KNX by means of both the 1-byte Mode objects for controlling and indicating the status of the corresponding mode. Simplified Modes The selection of the Simplified Modes will enable a 1-bit communication object with the same name that will allow choosing between Mode Cool (value 0) and Mode Heat (value 1). For this communication object, the corresponding status communication object does not exist. Figure 4.5 Mode 4.4. FAN SPEED In this window it can be selected the number of fan levels that the air conditioning unit has: 2 or 3 levels. The fan speed has two associated 1-byte communication objects that respectively controls and indicates the fan speed. The control object records the fan speed in percentage. For this reason this value will be interpolated in such a way that corresponds to the selected number of levels. The status object will show the fan speed according to the interpolated percentages. Two Levels of Fan Figure 2 Fan Speed If the fan speed configuration has 2 levels, the fan speed percentages will be interpolated in the following way: Initial Speed Interpolated Speed Level ZENNiO AVANCE Y TECNOLOGÍA 1 5
16 Percentage Percentage 0-49% 25 % Minimum % 100 % Maximum Three Levels of Fan On the other hand, with a fan speed configuration of 3 levels, the fan speed percentages will be interpolated according to the next table: Initial Speed Percentage Interpolated Speed Percentage Level 0-32% 25 % Minimum % 50 % Medium % 100 % Maximum Besides configuring the number of levels the Fan window allows selecting the Step Control. Step Control The selection of Step Control enables a 1-bit object for increasing or decreasing the fan speed level: Value 1 : Increase Value 0 : Decrease The Step Control is not cyclical which means that if the fan speed is Minimum (0%), when the speed level is decreased, the speed will remain at this mode until the level is increased again. The same way, when the speed level is at 100%, the level will remain at this maximum until the speed is decreased SCENES A scene involves the synchronized sending of several commands to the air conditioning unit with the objective of generating a determined climate environment in the room. KLIC offers the possibility of configuring up to 4 scenes. ZENNiO AVANCE Y TECNOLOGÍA 1 6
17 Figure 4.7 Scenes Once the Scenes are enabled in General, the option Scenes appears in the Menu. For each of the 4 scenes, the variables that can be configured are: Scene1-4: Figure 4.8 Scenes Configuration Example Scene Number: Scene number within the installation. ON/OFF: No change, switching ON or OFF the Split. Temperature: No change or temperature value between 16 C and 32 C. Mode: No change, auto, heat, dry, fan or cool. Fan: No change, minimum, medium o maximum TEMPERATURE LIMITATION ZENNiO AVANCE Y TECNOLOGÍA 1 7
18 The air conditioning unit has defined upper and lower temperature limits that cannot be exceeded (the limits are usually 32ºC and 16ºC respectively). Nevertheless, KLIC offers the possibility of establishing new temperature limits if they are specified within the limits of the indoor unit The temperature limits can be personalized for the two modes with associated temperature: Cool and Heat. Figure 4.9 Temperature Limitation Once the limitation is enabled, when a value out of the range is sent from the bus KNX, the value that will be sent to the A/C unit will be the corresponding temperature limit and this new temperature value will be notified to the bus KNX. As a new functionality, it has been included a 1-bit communication object that will allow the user enabling (object to 1 ) or disabling (object to 0 ) these personalized temperatures restoring the unit default range. Take into account: When configuring in ETS the temperature limitation, this functionality is automatically enabled by default and the personalized ranges will control the unit performance when it switches on AUTOMATIC SWITCH OFF ZENNiO AVANCE Y TECNOLOGÍA 1 8
19 When this option is enabled, the air conditioning unit will be temporarily switched off if a status change in the associated binary communication object is produced. This functionality has one configurable parameter: Delay for Auto-OFF: Number of seconds that KLIC-DI delays the air conditioning unit switching off. Figure 4.10 Auto-OFF 4.8. S MANAGEMENT The Errors Management window allows enabling the sending of messages to the bus indicating any error that may arise: internal errors of the communication between the KLIC-DI and the A/C unit or external errors, errors in the own A/C unit. It can be enabled the internal errors, the external errors or both: Internal Errors: Yes or no. External Errors: Yes or no. Every error type has associated two communication objects: the binary one indicates if an error has occurred and the 1-byte object that indicates the code identifying the error. Figure 3 Errors Management 4.9. INITIAL CONFIGURATION The initial configuration window allows configuring the initial machine status after the installation or a power failure. ZENNiO AVANCE Y TECNOLOGÍA 1 9
20 The variables that can be initialized are the following: ON/OFF: Last, ON or OFF. Temperature: Last or custom. Mode: Last, auto, heat, dry, fan or cool. Fan: Last, auto, minimum, minimum-medium, medium, maximummedium or maximum. Moreover, it can be configured the Sending of status to the Bus or Split and when it must be carried out: Send Initial Configuration to?: Yes or no. Delay: number of seconds that the KLIC delays the sending of status to the Figure 4 Initial Configuration ZENNiO AVANCE Y TECNOLOGÍA 2 0
21 ANNEX I. COMMUNICATION OBJECTS SECTION NUMBER LENGHT IN/OUT FLAGS VALUES RANGE INITIAL RESET NAME OBJECT FUNCTION 0 1 bit I W 0/1 0 ON/OFF Turn ON the Split(1); Turn OFF the Split(0) 1 2 bytes I W Temperature Temperature sent to the Split 2 1 byte I W Mode Auto(0); Heat(1); Cool(3); Fan(9);Dry(14) 3 1 byte I W Fan With 2 levels: Minimum (0-49%); Maximum (50%- 100%) With 3 levels: Minimum (0-32%); Medium(33%- 65%); Maximum (66%-100%) 4 1 bit R-T 0/1 ON/OFF (Status) Split State (ON/OFF) 5 2 bytes R-T Temperature (Status) Temperature received from the split GENERAL 6 1 byte R-T Mode (Status) Mode received from the split 7 1 byte R-T Fan (Status) With 2 levels: Minimum (25%); Maximum (100%) With 3 levels: Minimum (25%); Medium(50%); Maximum (100%) 20 1 byte I W Scenes Set Scene Value (Scene Number) 21 1 bit I W 0/1 Temperature Limitation Enable(1); Disable(0) 22 1 bit I W 0/1 Auto-OFF Enable(1); Disable(0) 27 2 bytes R-T Indoor Temperature (Estado) Temperature measured by the machine 28 2 bytes W Reference Temperature Reference temperature 8 1 bit I W-T 0/1 Auto Mode Set Auto Mode(1); Nothing(0) ZENNiO AVANCE Y TECNOLOGÍA 2 1
22 SECTION NUMBER LENGHT IN/OUT FLAGS VALUES RANGE INITIAL RESET NAME OBJECT FUNCTION 9 1 bit I W-T 0/1 Cool Mode Set Cool Mode (1); Nothing (0) 10 1 bit I W-T 0/1 Heat Mode Set Heat Mode (1); Nothing (0) 11 1 bit I W-T 0/1 Fan Mode Set Fan Mode (1); Nothing (0) 12 1 bit I W-T 0/1 Dry Mode Set Dry Mode (1); Nothing (0) 13 1 bit I W 0/1 Simplified Mode Cool(0); Heat(1) 14 1 bit R-T 0/1 Auto Mode (Status) Auto Mode Enabled (1); Disabled (0) MODE 15 1 bit R-T 0/1 Cool Mode (Status) Cool Mode Enabled (1); Disabled (0) 16 1 bit R-T 0/1 Heat Mode (Status) Heat Mode Enabled (1); Disabled (0) 17 1 bit R-T 0/1 Fan Mode (Status) Fan Mode Enabled (1); Disabled (0) 18 1 bit R-T 0/1 Dry Mode (Status) Dry Mode Enabled (1); Disabled (0) FAN 19 1 bit I W 1 Fan [1bit] (Status) Down(0); Up(1) 23 1 bit R-T 0/1 Internal Error (Status) No error(0); Error(1) S MANAGEMENT 24 1 byte R-T 1-4 Type of Internal Error (Status) 25 1 bit R-T 0/1 External Error (Status) No error(0); Error(1) Err.Reception(1);Timeout (2); Incorrect Checksum (3); Incorrect Response(4) 26 1 byte R-T Type of External Error (Status) Check A/C unit Errors Table LOGICAL FUNCTIONS Several W-C [Logical Functions] Data Entry and Result objects of function ZENNiO AVANCE Y TECNOLOGÍA 2 2
23 ANNEX II. CORRESPONDENCE S OF A/C UNITS Next table shows the correspondence between the external error code provided by KLIC-DI at the Bus KNX and the breakdown codes of the A/C units: AH 53 E5 79 HF 105 J9 131 P3 157 UJ H AC 54 E6 80 F0 106 JA 132 P4 158 UE C AJ 55 E7 81 F1 107 JH 133 P5 159 UF J AE 56 E8 82 F2 108 JC 134 P A E AF 57 E9 83 F3 109 JJ 135 P H F C0 58 EA 84 F4 110 JE 136 P C C1 59 EH 85 F5 111 JF 137 P J C2 60 EC 86 F6 112 L0 138 PA E C3 61 EJ 87 F7 113 L1 139 PH F A 36 C4 62 EE 88 F8 114 L2 140 PC A H 37 C5 63 EF 89 F9 115 L3 141 PJ H C 38 C6 64 H0 90 FA 116 L4 142 PE C J 39 C7 65 H1 91 FH 117 L5 143 PF J E 40 C8 66 H2 92 FC 118 L6 144 U A E F 41 C9 67 H3 93 FJ 119 L7 145 U H F A0 42 CA 68 H4 94 FE 120 L8 146 U C A 17 A1 43 CH 69 H5 95 FF 121 L9 147 U J H 18 A2 44 CC 70 H6 96 J0 122 LA 148 U E C ZENNiO AVANCE Y TECNOLOGÍA 2 3
24 19 A3 45 CJ 71 H7 97 J1 123 LH 149 U F J 20 A4 46 CE 72 H8 98 J2 124 LC 150 U A E 21 A5 47 CF 73 H9 99 J3 125 LJ 151 U H F 22 A6 48 E0 74 HA 100 J4 126 LE 152 U C A7 49 E1 75 HH 101 J5 127 LF 153 U J A8 50 E2 76 HC 102 J6 128 P0 154 UA E A9 51 E3 77 HJ 103 J7 129 P1 155 UH F AA 52 E4 78 HE 104 J8 130 P2 156 UC A ZENNiO AVANCE Y TECNOLOGÍA 2 4
25 SIGN UP! TECHNICAL SUPPORT ZENNIO TECHNICAL DOCUMENTATION 2 5
KLIC-DI VRV PRODUCT MANUAL INTERFACE KNX DAIKIN VRV ZN1CL-KLIC-DI. Edition 4 Version 1.0
PRODUCT MANUAL KLIC-DI VRV INTERFACE KNX VRV ZN1CL-KLIC-DI Edition 4 Version 1.0 Index 1. Introduction... 3 2. Installation... 5 2.1. KLIC-DI Installation... 5 2.2. Elements Description... 6 3. Configuration...
More informationTechnical Note: Installation Note
INTRODUCTION KLIC-DI is an interface that allows a bidirectional communication between a KNX domotic system and the commercial air-conditioning s of the commercial and industrial series. This device controls
More informationIntesisBox DK-RC-MBS-1 v.0.2
IntesisBox DK-RC-MBS-1 v.0.2 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2011/05/05 Order
More informationIntesisBox DK-RC-MBS-1 v.0.8
IntesisBox DK-RC-MBS-1 v.0.8 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2013/02/26 Order
More informationPRODUCT MANUAL LUZEN PLUS. Universal Dimmer ZN1DI-P400. Program version: 3.0 Manual edition: a
PRODUCT MANUAL LUZEN PLUS Universal Dimmer ZN1DI-P400 Program version: 3.0 Manual edition: a INDEX Document updates... 3 1. Introduction... 4 1.1. LUZEN PLUS... 4 1.2. Types of load... 5 1.3. Installation...
More informationAUGUST 2017 SUG/U 1.1 Split Unit Gateway Product presentation. STO/GPS, Product Management
AUGUST 2017 Product presentation STO/GPS, Product Management Agenda Overview Functionality System overview Technical information Commissioning Diagnosis i-bus Tool August 25, 2017 Slide 2 What is a? The
More informationThe best solution for home electronic integration
The best solution for home electronic integration R 2 ZAS KNX Smart room controller Remote control ZN1VI-TPZAS-B 1:1 (120 x 88 x 11 mm.) ZN1VI-TPZAS-S ZN1VI-TPZAS-W ZN1IR-ZAS (85.5 x 54 x 12 mm.) ZAS room
More informationCIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. Router A Router B Router C Router D Network Next Hop Next Hop Next Hop Next
More informationThe best solution for home electronic integration
The best solution for home electronic integration R 2 TOUCH PANEL Z.A.S. (Zennio Analog Screen) KNX Smart room controller Remote control ZN1VI-TPZAS-AN 1:1 (120 x 88 x 11 mm.) ZN1VI-TPZAS-S ZN1VI-TPZAS-PW
More informationThe best solution for home electronic integration
The best solution for home electronic integration R 2 ZAS KNX Smart room controller Remote control ZN1VI-TPZAS-B 1:1 (120 x 88 x 11 mm.) ZN1VI-TPZAS-W ZN1IR-ZAS ZAS room controller is a great solution
More informationSWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION
SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION MODEL TYPE NO. SG HOKUSPOKUS KNX/KLR 25010 Program version 2.7 2012 M. Züblin AG Neue Winterthurerstrasse 30, 8304 Wallisellen, Switzerland The
More informationIntegration Note OVERVIEW AND SUPPORTED FEATURES
Manufacturer: Model Number(s): KNX Climate (Various) Minimum Core Module g! 5.4 Version: g! 6.2 Minimum for Fan Coil Climate Modes Document Revision Date: 10/8/2015 OVERVIEW AND SUPPORTED FEATURES Integration
More informationCIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1
Version 1 Instructions Write your name on the exam paper. Write your name and version number on the top of the yellow paper. Answer Question 1 on the exam paper. Answer Questions 2-4 on the yellow paper.
More informationKNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).
PRODUCT NEWS Products News: New HC-A16KNX PAGE 1 / 8 Summary 1. This advanced product news introduces the new product HC-A16KNX. 2. The details are indicated in the description. Description 1. Applicable
More informationUSER'S MANUAL. IntesisBox KNX K01-KNX-1B/16/64 v1.0. r1 eng Issue Date: 2014/06
USER'S MANUAL IntesisBox KNX K01-KNX-1B/16/64 v1.0 r1 eng Issue Date: 2014/06 Interface for integration of Kaysun air conditioners into KNX TP-1 (EIB) control systems. Compatible with VRF air conditioners
More informationS5-115U. Application
S5-115U S5-115U Design Central configuration Distributed configuration Note General technical specifications S5-115U Principle of operation Program memory Processor Programming S5-115U Cyclic program execution
More informationS5-115U. Application
S5-115U Application S5-115U Design Central configuration Distributed configuration Note General technical specifications S5-115U Principle of operation Program memory Processor Programming S5-115U Cyclic
More informationECHO Process Instrumentation, Inc. Modbus RS485 Module. Operating Instructions. Version 1.0 June 2010
ECHO Process Instrumentation, Inc. Modbus RS485 Module Operating Instructions Version 1.0 June 2010 ECHO Process Instrumentation, Inc. PO Box 800 Shalimar, FL 32579 PH: 850-609-1300 FX: 850-651-4777 EM:
More informationIntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN
IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017
More informationCommunications guide. Line Distance Protection System * F1* GE Digital Energy. Title page
Title page GE Digital Energy D90 Plus Line Distance Protection System Communications guide D90 Plus firmware revision:.9x GE publication code: 60-9070-F (GEK-3469) GE Digital Energy 650 Markland Street
More informationPRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX. Product Handbook
PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX Product Handbook Product: PD00D01KNX Description: PRESENCE DETECTOR, CONSTANT CONTROLLER Document Version: 1.3 Date: 03/10/2017 Tribunale di Mila
More informationPassion for KNX innovation
Passion for KNX innovation Touch-MyDesign 2 ZVI-TMDP4 ZN1AC-UPFRCR (122.7 x 90.2 x 12 mm.) Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building
More informationCIS-331 Exam 2 Fall 2015 Total of 105 Points Version 1
Version 1 1. (20 Points) Given the class A network address 117.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 4,000 subnets? b. (5 Points) What is
More informationTemperature Probe Input Module for External Temperature Probes
Input Module for External Temperature Probes User Manual Version: [0.1]_b USER MANUAL www.zennio.com Contents Document Updates... 3 1 Introduction... 4 2 Configuration... 5 2.1 General... 5 2.2 Custom
More informationSIMATIC S Central processing units
SIMATIC S7-1500 Siemens AG 2013 Overview CPU 1511-1 PN PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under
More informationINTRODUCTION... 3 DEVICE S CONFIGURATION... 4 KNX CONFIGURATION. SKX LINKER Hardware Configuration Objects Selection...
SKX LINKER PRONTO INDEX INTRODUCTION... 3 DEVICE S CONFIGURATION... 4 KNX CONFIGURATION. SKX LINKER... 5 Hardware Configuration... 5 Objects Selection... 6 Control Objects. ZENNIO specific spreadsheet....
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationCIS-331 Fall 2013 Exam 1 Name: Total of 120 Points Version 1
Version 1 1. (24 Points) Show the routing tables for routers A, B, C, and D. Make sure you account for traffic to the Internet. NOTE: Router E should only be used for Internet traffic. Router A Router
More informationTemperature Probe Input Module for External Temperature Probes
USER MANUAL Temperature Probe Input Module for External Temperature Probes User Manual Version: [1.0]_a www.zennio.com CONTENTS Contents... 2 Document Updates... 3 1 Introduction... 4 2 Configuration...
More informationCIS-331 Exam 2 Fall 2014 Total of 105 Points. Version 1
Version 1 1. (20 Points) Given the class A network address 119.0.0.0 will be divided into a maximum of 15,900 subnets. a. (5 Points) How many bits will be necessary to address the 15,900 subnets? b. (5
More informationMM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning
MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning Installation and User Guide www.microtrol.co.uk Contents 1. Supplied Parts...2 2. Important Information...3 3. Product Overview...4
More informationKNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems
KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems Document Revision 0.5 5/30/2018 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected
More informationIntesisBox TO-RC-MBS-1
IntesisBox TO-RC-MBS-1 v.1.5 MODBUS RTU (EIA485) Interface for Toshiba air conditioners from the Digital Inverter & VRF lines. User Manual Issue Date: 01/2014 Order Codes: TO-RC-MBS-1 Intesis Software
More informationInstallation Manual. DZK BACnet
Installation Manual DZK BACnet InterfacepbilCodarPageNumber TABLE OF CONTENTS Page Overview... 5 Outline and Features... 5 System outline... 5 Specifications and device elements... 6 Functional specifications...
More informationKNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems
KNX Module User Guidelines KNX Module Universal Interface Adapter for HVAC Systems Document Revision 0.4 9/8/2017 Attention 1. During the HVAC system automatic operations the CoolMasterNet must be disconnected
More informationSPARE CONNECTORS KTM 2014
SPAREPARTSCATALOG: // ENGINE ART.-NR.: 3208201EN CONTENT CONNECTORS FOR WIRING HARNESS AA-AN CONNECTORS FOR WIRING HARNESS AO-BC CONNECTORS FOR WIRING HARNESS BD-BQ CONNECTORS FOR WIRING HARNESS BR-CD
More informationZN-DN312XE-M Quick User Guide
ZN-DN312XE-M Quick User Guide This manual provides instructions for quick installation and basic configuration of your IP device. Step1. Connect cables to IP device Connect required cables to the device
More informationCommunicative controller for VAV systems
FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration
More informationSTANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1
STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1 SUMMARY Hardware technical specifications... 3 Front Face of the 512 / 1024 channels interfaces... 4 Side Faces of the 512 / 1024 channels interfaces...
More informationLMV2 / LMV3... Modbus. User Documentation. Building Technologies Division
LMV2 / LMV3... Modbus User Documentation The LMV2... / LMV3... burner management system and this User Documentation are intended for OEMs and system integrators which integrate the system in their products!
More informationIntesisBox PA-AW-MBS-1 v.2.0
IntesisBox PA-AW-MBS-1 v.2.0 Modbus RTU (EIA485) Interface for Panasonic Aquarea series. User Manual Issue Date: 08/2014 r2.0 Order Code: PA-AW-MBS-1: Modbus RTU Interface for Panasonic Aquarea series
More informationHardware technical specifications Front Face of the 512 / 1024 channels interfaces LED 7-segments display operation:...
SUMMARY Hardware technical specifications... 4 Front Face of the 512 / 1024 channels interfaces... 5 LED 7-segments display operation:... 5 LED 7-segments Sleep option:... 6 selection Mode button... 6
More informationDin Rail Universal Module 8 inputs / 8 outputs IO88E01KNX
Din Rail Universal Module 8 inputs / 8 outputs IO88E01KNX Product Handbook Product Description: Din Rail Universal 8 in / 8 out Module Order Code: IO88E01KNX Document Version: 1.1 Date: 22/07/2011 1/64
More informationSPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN
SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS
More informationGateway Ascii Command Protocol
Gateway Ascii Command Protocol Table Of Contents Introduction....2 Ascii Commands.....3 Messages Received From The Gateway....3 Button Down Message.....3 Button Up Message....3 Button Maintain Message....4
More informationCIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1
Version 1 1. (20 Points) Given the class A network address 121.0.0.0 will be divided into multiple subnets. a. (5 Points) How many bits will be necessary to address 8,100 subnets? b. (5 Points) What is
More informationDatasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10
General Description Room Control Unit RCU Series are designed as an all in one product for different room layouts such as apartments, hotel rooms, hospitals and residences. Available versions of EAE RCU
More informationIntesisBox KNX - Mitsubishi Electric G50
IntesisBox KNX - Mitsubishi Electric G50 Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems. Integrate Mitsubishi Electric City Multi Air Conditioning systems
More informationIntesisBox. v.2.5. User Manual Issue Date: 12/2017 r1.9 EN. Modbus RTU (EIA-485) Interface for Fujitsu air conditioners.
IntesisBox FJ-RC-MBS-1 v.2.5 Modbus RTU (EIA-485) Interface for Fujitsu air conditioners. User Manual Issue Date: 12/2017 r1.9 EN Order Codes: FJ-RC-MBS-1: Modbus RTU Interface for Fujitsu air conditioners
More informationInstallation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC
Installation Instructions Procon IP-32M 2371-wir-1_2-0204 MITSUBISHI ELECTRIC Procon IP-32M Overview The Procon IP-32M unit provides an interface between a Mitsubishi City-Multi G50A controller with up
More informationIntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.
IntesisBox KNX - Mitsubishi Electric G50 Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems. Integrate Mitsubishi Electric City Multi Air Conditioning systems
More informationABB i-bus KNX SUG/U 1.1 Split Unit Gateway Product Manual
SUG/U 1.1 Split Unit Gateway Product Manual Contents Contents Page 1 General... 3 1.1 Using the product manual...3 1.1.1 Notes...4 1.2 Overview of product and functions...5 1.2.1 Integration in the i-bus
More informationVenstar Thermostat Adapter
Developer Venstar Thermostat Adapter v001 Developer Venstar Thermostat Adapter Version 001 May 23, 2013 Revision History Rev Date Comments 001 05/23/13 Initial Release Page 1 of 13 Table of Contents 1
More information4 CHANNEL UNIVERSAL DIMMING ACTUATOR
4 CHANNEL UNIVERSAL DIMMING ACTUATOR USER MANUAL Tel.: 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com General Description - 4 Channel universal modular dimming actuator for leading and trailing edge
More informationRCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs
revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint
More informationDESCRIPTION OF MODBUS CONNECTION
DESCRIPTION OF MODBUS CONNECTION MODBUS CONNECTION There is a possibility to control Air Handling Unit (AHU) from external management system (BMS), which work with MODBUS data processing. For MODBUS connection
More informationSTRA-17 Room controller. Installation and maintenance manual. Content
Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8
More information4. Specifications and Additional Information
4. Specifications and Additional Information AGX52004-1.0 8B/10B Code This section provides information about the data and control codes for Arria GX devices. Code Notation The 8B/10B data and control
More informationIntesisBox ModBus RTU Fujitsu Air Conditioning
IntesisBox ModBus RTU Fujitsu Air Conditioning Compatible with Domestic and VRF line air conditioners commercialized by Fujitsu User Manual 03/2019 r1.0 eng Intesis Software S.L.U. 2019 All Rights Reserved.
More information2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER No.KTC3E2 2006.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. For this product
More informationDin Rail 4 Output Module BO04A01KNX
Din Rail 4 Output Module BO04A01KNX Product Handbook Product Description: Din Rail 4 Output Module Order Code: BO04A01KNX Document Version: 1.1 Date: 28/01/2014 1/45 INDEX 1. General Introduction... 4
More informationThermoPad Reference Manual
ThermoPad Reference Manual Revision 0.6 www.coolautomation.com 2/18/2015 2 Table of Contents 1 Revision History 3 2 Specification 4 3 Thermopad Models 5 4 Terminals 6 5 MODBUS Map 7 6 Special Features
More informationRCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs
revision 11 2013 RCF-230CD Communicating room thermostat for fan-coil applications with on/off outputs RCF-230CD intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan
More informationDin Rail 8 Input / 8 Output Module
Din Rail 8 Input / 8 Output Module IO88B02KNX Product Handbook Product: Din Rail 8 Input / 8 Output Module Order Code: IO88B02KNX 1/32 INDEX 1. General Introduction... 3 2. Product and functional overview...
More informationInterface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016
Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation
More information10. RS-232C communication
10. RS-232C communication PB9200(P5XMLA) Connecting the cable (1) Turn off the projector and the computer power supplies. (2) Connect the CONTROL port of the projector with a RS-232C port of the computer
More informationFCU-4 FAN COIL CONTROLLER
FCU-4 FAN COIL CONTROLLER BACnet Enabled Description The FCU-4 is designed to provide complete control of fan coil units. The FCU-4 incorporates all the inputs and outputs to ensure that this advanced
More informationIntesisBox SMS - Mitsubishi Electric air conditioners
Order code ME-AC-SMS-32 IntesisBox SMS - Mitsubishi Electric air conditioners Controller with SMS interface for monitoring and control Mitsubishi Electric air conditioners. Control your Mitsubishi Electric
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationFANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook
FANCOIL CONTROLLER UNIT TC17B01KNX Product Handbook Product: TC17B01KNX Description: FANCOIL CONTROLLER UNIT Document Version: 1.2 Date: 09/09/2016 1/37 INDEX 1. General Introduction... 4 2. Product and
More informationCIS-331 Final Exam Spring 2015 Total of 115 Points. Version 1
Version 1 1. (25 Points) Given that a frame is formatted as follows: And given that a datagram is formatted as follows: And given that a TCP segment is formatted as follows: Assuming no options are present
More informationIntesisBox KNX. User Manual v10 r10 eng. Mitsubishi Electric air conditioners (Domestic & Mr.Slim lines) Release V.0.2
IntesisBox KNX Mitsubishi Electric air conditioners (Domestic & Mr.Slim lines) Release V.0.2 User Manual v10 r10 eng Intesis Software S.L. All Rights Reserved. Information in this document is subject to
More informationCIS-331 Final Exam Spring 2018 Total of 120 Points. Version 1
Version 1 Instructions 1. Write your name and version number on the top of the yellow paper and the routing tables sheet. 2. Answer Question 2 on the routing tables sheet. 3. Answer Questions 1, 3, 4,
More informationeelecta & new products
eelecta & new products Home and Building Evolution Eelectron - Via Magenta 77/22, I-20017 Rho (MI), Italy Eric Ducros eric.ducros@eelectron.com +39 02.9316681 www.eelectron.com info@eelectron.com www.eelectron.com
More information/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500
1473-1-8913 / 2CKA001473B8913 23.03.2016 KNX Technical Reference Manual ABB i-bus KNX Room temperature controller with display 6108/18-500 Table of contents Table of contents 1 s on the instruction manual...
More informationWIRED REMOTE CONTROLLER OPERATION MANUAL
WIRED REMOTE CONTROLLER OPERATION MANUAL BRCE6 Thank you for purchasing this product. This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure
More informationDigital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module
, Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION
More informationDK-AC-KNX-1. Specifications. Main features. Info
IntesisBox 2015 DK-AC-KNX-1 IntesisBox DK-AC-KNX-1 allows monitoring and control, fully bi-directionally, all the operational parameters of DAIKIN air conditioners from KNX installations. Compatible with
More informationElotech Standard Protocol. for Single R8200 SC
Elotech Standard Protocol interface description / network protocol for Single R8200 SC ELOTECH Industrieelektronik GmbH Verbindungsstraße 27 D - 40723 HILDEN FON +49 2103 / 255 97 0 FAX +49 2103 / 255
More informationIntesisBox PA-AC-MBS-1
IntesisBox PA-AC-MBS-1 v.2.3 Modbus RTU (EIA-485) Interface for Panasonic air conditioners. Compatible with Etherea line air conditioners commercialized by Panasonic. User s Manual Issue Date: 11/2017
More informationIntesisBox. v.1.3. User Manual Issue Date: 04/2016. IntesisBox PA-RC2-MBS-4
IntesisBox PA-RC2-MBS-4 v.1.3 MODBUS RTU (EIA485) Interface for Panasonic and Sanyo air conditioners. Compatible with ECOi and PACi line models. User Manual Issue Date: 04/2016 Order Codes: PA-RC2-MBS-4
More informationIntesisBox KNX SAMSUNG NASA Air Conditioners
IntesisBox KNX SAMSUNG NASA Air Conditioners Gateway for integration of Samsung NASA air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX/EIB bus R1/R2 EIA485 SM-ACN-KNX-4-8-16-64
More informationDigital Lighting Systems, Inc.
Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical
More informationRCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater
revision 03 2012 RCF-230CTD Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater RCF-230CTD is a room controller intended
More informationKNX TinySerial 810. Communication Protocol. WEINZIERL ENGINEERING GmbH
WEINZIERL ENGINEERING GmbH KNX TinySerial 810 Communication Protocol WEINZIERL ENGINEERING GmbH Bahnhofstr. 6 DE-84558 Tyrlaching GERMAY Tel. +49 8623 / 987 98-03 Fax +49 8623 / 987 98-09 E-Mail: info@weinzierl.de
More informationManual and application description 4 channel 0-10V dimmer V2.0
1 Manual and application description 4 channel 0-10V dimmer V2.0 2 1. Device description 1.1 General 0-10V dimmer is used for proportional control of 4 electronic ballasts with 1-10 V signal. There are
More informationUse of the application program
Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order no.: Name: Order
More informationDeveloper Notes INSTEON Thermostat v012. Developer Notes. INSTEON Thermostat. Revision History
Developer INSTEON Thermostat v012 Developer INSTEON Thermostat Version 012 June 19, 2012 Revision History Rev Date Comments 001 10/28/11 Initial Release 002 11/4/11 Updated formatting in some sections
More informationTHERMO-CON. Model No. HECR002-A5. Keep available whenever necessary.
HEC-OM-S008 Aug.2014 Communication Manual THERMO-CON Model No. HECR002-A5 Keep available whenever necessary. This manual is copyrighted and all rights are reserved by SMC Corporation, and may not, in whole
More informationCoolMaster Programmers Reference Manual (PRM)
CoolMaster Programmers Reference Manual (PRM) CoolMaster Interface Adapter for VRV, VRF Air Conditioning Systems Cool Master 1000D Cool Master 2000S Cool Master 3000T Cool Master 4000M Version 3.0 8/12/2009
More informationTechnical Manual. KNX/DALI ACTUATOR 1x8 channels Art /70100
KNX/DALI ACTUATOR 1x8 channels Art. 1630.04140/70100 DATEC ELECTRONIC AG Hochbergerstrasse 60C 4057 Basel Tel. +41 61 633 22 25, Fax. +41 61 633 22 27 www.datec.ch, support@datec.ch Because of continuous
More informationOperation and installation manual KNX IO 511 (1O2I) Application. 1. Installation and Connection
EN Operation and installation manual KNX IO 511 (1O2I) (Art. # 5232) Switching actuator with 1 output and 2 binary inputs A. KNX Programming mode The KNX programming mode is activated/deactivated either
More informationManual and application description KNX/EIB LED driver V2.0
1 Manual and application description KNX/EIB LED driver V2.0 2 1. Device description 1.1 General KNX/EIB LED allows dimming one RGB LED strip as well as 3 standard LED lamps. There are also three binary
More informationKNX S4-B10 230V. Multifunctional Actuator. Installation and Adjustment
EN KNX S4-B10 230V Multifunctional Actuator Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical data... 4 2. Installation and start-up... 5 2.1. Notes on installation... 5 2.2. Device
More informationTK4S temperature controller
TK4S temperature controller Table of Contents Thank Purchase Instructions... iii Manual Guide... iv Communication protocols... v Table of Contents... vii 1 Modbus RTU Protocols... 1.1 Read Coil Status(Func01
More informationRegister Map: Ecoflair Indirect Air Economizer
Register Map: Ecoflair Indirect Air Economizer Notes: 1. 16-bit registers (INT16, UINT16, ENUM) are transmitted MSB first (i.e., big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least
More informationJCL-33A (C5) Warning. 1. System Configuration COMMUNICATION INSTRUCTION MANUAL
COMMUNICATION INSTRUCTION MANUAL JCL-33A (C5) No.JCL3CE3 2018.11 This manual contains instructions for the communication functions, operations and notes when operating the JCL-33A. To prevent accidents
More informationTHT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE
COMMUNICATION INSTRUCTION MANUAL THT-500-A/R (C5) No. THT5CE2 2018.04 This manual contains instructions for communication functions of the THT-500-A/R. 1. System Configuration 1.1 When Using USB Communication
More informationRCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs
revision 01 2015 RCF-230CAD Communicating room controller for fan-coil applications with two analogue 0...10 V DC outputs RCF-230CAD intended to control heating and/or cooling in 2- or 4-pipe installations.
More informationOPERATION INSTRUCTIONS
2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT
More information