Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)
|
|
- Oswald Hawkins
- 6 years ago
- Views:
Transcription
1 K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category voltage contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg Screw clamp LC-K060ii 0.80 LC-K060ii 0.80 Faston LC-K0607ii 0.80 x 6.35 LC-K0607ii 0.80 Solder pins LC-K0605ii 0.20 for printed LC-K0605ii Screw clamp LC-K090ii 0.80 LC-K090ii 0.80 Faston LC-K0907ii 0.80 x 6.35 LC-K0907ii 0.80 Solder pins LC-K0905ii 0.20 for printed LC-K0905ii 0.20 a.c. control contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Screws in the open ready-to-tighten position Screw clamp LC7-K060ii LC7-K060ii Faston LC7-K0607ii x 6.35 LC7-K0607ii Solder pins LC7-K0605ii for printed LC7-K0605ii Screw clamp LC7-K090ii LC7-K090ii Faston LC7-K0907ii x 6.35 LC7-K0907ii Solder pins LC7-K0905ii for printed LC7-K0905ii () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages, see page opposite. Contactors LC-K, LC7-K, LP-K On panel LA-K 4xØ4 On mounting rail AM-DP200 or AM-DE200 (" 35 mm) 3 = 50 = = 35 = /2 Te
2 K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : d.c. a LP-K060ii d.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category voltage contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg Screw clamp LP-K060ii LP-K060ii Faston LP-K0607ii x 6.35 LP-K0607ii Solder pins LP-K0605ii for printed LP-K0605ii Screw clamp LP-K090ii LP-K090ii Faston LP-K0907ii x 6.35 LP-K0907ii Solder pins LP-K0905ii for printed LP-K0905ii () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Contactors LC-K (0.8.5 Uc) (0.85. Uc) Volts c / 220/ / / /60 Hz Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts c 400/ / 50/60 Hz 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available : add 2 to the code required. Example : J72 Contactors LC7-K (0.85. Uc) Volts c / 50/60 Hz 240 Code B7 D7 E7 F7 M7 U7 Contactors LP-K (0.8.5 Uc) Volts a Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPDMUD UD Coil with integral suppression device available : add 3 to the code required. Example : JD3 Contactors LC-K, LC7-K, LP-K On one asymmetrical rail DZ5-MB with clip-on mounting plate LA9-D973 DX-AP25 On printed DZ5-ME ,65 === 50 A 53 2 = 35 = 5 0xØ,3 A2 27 Te /3
3 Dimensions : pages /2 and /3 Mini contactors K 3 and 4-pole contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : a.c. and d.c. c a.c. control contactors () - Mounting on 35 mm " rail or Ø 4 mm screws. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg LC-K09004ii 20 Screw clamp 3 LC-K090ii LC-K090ii LC-K09004ii LC-K09008ii 0.80 Faston 3 LC-K0907ii x LC-K0907ii LC-K090047ii LC-K090087ii 0.80 Solder pins 3 LC-K0905ii for printed 3 LC-K0905ii LC-K0900ii LC-K090085ii 0.22 a.c. control contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. 20 Screw clamp 3 LC7-K090ii LC7-K090ii LC7-K09004ii LC7-K09008ii Faston 3 LC7-K0907ii x LC7-K0907ii LC7-K090047ii LC7-K090087ii Solder pins 3 LC7-K0905ii for printed 3 LC7-K0905ii LC7-K0900ii LC7-K090085ii d.c. control contactors () 20 Screw clamp 3 LP-K090ii LP-K090ii LP-K09004ii LP-K09008ii Faston 3 LP-K0907ii x LP-K0907ii LP-K090047ii LP-K090087ii Solder pins 3 LP-K0905ii for printed 3 LP-K0905ii LP-K0900ii LP-K090085ii () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages, see page /3. /4 Te
4 Dimensions : page /6 Mini contactors K 3-pole reversing contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. and d.c. c a.c. control reversing contactors () LC2-K060ii - Integral mechanical interlock. - Pre-wired power circuit connections as standard on screw clamp versions. Standard power ratings Rated Type of Instantaneous Basic reference. Weight of 3-phase motors operational connection auxiliary Complete with code 50/60 Hz in category current contacts indicating control AC-3 in AC-3 circuit voltage (2) up to 220 V 380 V 440/500 V 400 V 230 V V 660/690 V kw kw kw A N/O N/C kg Screw clamp LC2-K060ii LC2-K060ii Faston LC2-K0607ii x 6.35 LC2-K0607ii Solder pins LC2-K0605ii for printed LC2-K0605ii Screw clamp LC2-K090ii LC2-K090ii Faston LC2-K0907ii x 6.35 LC2-K0907ii Solder pins LC2-K0905ii for printed LC2-K0905ii a.c. control reversing contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. - Pre-wired power circuit connections as standard on screw clamp versions. - Mounting on " 35 mm rail or Ø 4 mm screw fixing Screw clamp LC8-K060ii LC8-K060ii Faston LC8-K0607ii x 6.35 LC8-K0607ii Solder pins LC8-K0605ii for printed LC8-K0605ii Screw clamp LC8-K090ii LC8-K090ii Faston LC8-K0907ii x 6.35 LC8-K0907ii Solder pins LC8-K0905ii for printed LC8-K0905ii d.c. control reversing contactors () Screw clamp LP2-K060ii LP2-K060ii Faston LP2-K0607ii x 6.35 LP2-K0607ii Solder pins LP2-K0605ii for printed LP2-K0605ii Screw clamp LP2-K090ii LP2-K090ii Faston LP2-K0907ii x 6.35 LP2-K0907ii Solder pins LP2-K0905ii for printed LP2-K0905ii () Auxiliary contact blocks and accessories, see pages /8 to /. (2) Control circuit voltage codes, see page /7. Te /5
5 K 3 and 4-pole changeover contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : a.c. c a.c. control reversing contactors () - Integral mechanical interlock. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg 20 Screw clamp 3 LC2-K090ii (3) LC2-K090ii (3) LC2-K09004ii Faston 3 LC2-K0907ii x LC2-K0907ii LC2-K090047ii LC2-K090ii Solder pins 3 LC2-K0905ii for printed 3 LC2-K0905ii LC2-K0900ii a.c. control reversing contactors for use in sensitive environments () Recommended for use in areas sensitive to noise, high interference mains supplies, etc. - Coil with rectifier incorporated, suppressor fitted as standard. - Integral mechanical interlock. - Mounting on " 35 mm rail or Ø 4 mm screw fixing. 20 Screw clamp 3 LC8-K090ii (3) LC8-K090ii (3) LC8-K09004ii Faston 3 LC8-K0907ii x LC8-K0907ii LC8-K090047ii Solder pins 3 LC8-K0905ii for printed 3 LC8-K0905ii LC8-K0900ii () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Control circuit voltage codes, see page opposite. (3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard. Reversing contactors LC2-K, LC8-K, LP2-K On panel LA-K 8xØ4 On mounting rail AM-DP200 or AM-DE200 ( " 35 mm) 3 90 = 50 = = 80 = 90 /6 Te
6 K 3 and 4-pole changeover contactors for heating, lighting, etc., 20 A Utilisation category AC- Control circuit : d.c. a LP2-K090ii d.c. control reversing contactors () - Integral mechanical interlock. Non inductive Type of Number Instantaneous Basic reference. Weight loads connection of auxiliary Complete with code Category poles contacts indicating control AC- circuit voltage (2) Maximum current at θ 50 C A N/O N/C kg 20 Screw clamp 3 LP2-K090ii (3) LP2-K0900ii (3) LP2-K09004ii Faston 3 LP2-K0907ii x LP2-K0907ii LP2-K090047ii Solder pins 3 LP2-K0905ii for printed 3 LP2-K0905ii LP2-K0900ii () Add-on auxiliary contact blocks and accessories, see pages /8 to /. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Reversing contactors LC2-K (0.8.5 Uc) (0.85. Uc) Volts c / 220/ / / /60 Hz Code J7 Z7 B7 C7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 W7 UE7 Q7 V7 Volts c 400/ / 50/60 Hz 690 Code N7 R7 S7 SC7 X7 Y7 Up to and including 240 V, coil with integral suppression device available : add 2 to the code required. Example : J72 Reversing contactors LC8-K (0.85. Uc) Volts c / 50/60 Hz 240 Code B7 D7 E7 F7 M7 U7 Reversing contactors LP2-K (0.8.5 Uc) Volts a Code JD ZD BD CD ED ND SD KD FD GD PD QD LD MD MPD MUD UD Coil with integral suppression device available : add 3 to the code required. Example : JD3 (3) Warning: this reversing contactor is pre-wired for reverse motor operation as standard. On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or on 2 mounting plates DX-AP25. 2 x LA9-D973 2 x DX-AP25 DZ5-ME = 35 = 90 5 On printed for reversing contactors or 2 contactors mounted side by side ,65 === = = = 8,65 A A A2 A xØ,3 Te /7
7 LC,LC7,LP-K06,K09 LA-KN LA-KN M LC,LC7,LP-K06,K09 LA-KN LA2-KT2 LC,LC7,LP-K09 LA-KN P /8 Te
8 K 3 and 4-pole contactors, reversing and changeover contactors Instantaneous and time delay auxiliary contacts Illustrations : page /8 Instantaneous auxiliary contact blocks Recommended for standard applications Clip-on front mounting, block per contactor Type of connection Type of contactor Composition Reference Weight LA-KN40ii ii N/O N/C kg Screw clamp LC, LC7, LP 2 LA-KN or 4-pole 2 LA-KN02 () 0.0 LA-KN (2) LA-KN LA-KN LA-KN LA-KN3 (3) LA-KN04 (4) 0.0 Faston LC, LC7, LP 2 LA-KN x or 4-pole 2 LA-KN LA-KN LA-KN LA-KN LA-KN LA-KN LA-KN With terminal referencing conforming to standard EN 5002 Clip-on front mounting, block per contactor Screw clamp LC, LC7, LP 2 LA-KN02M pole LA-KNM and 9 A 3 LA-KN3M LA-KN22M LA-KN3M 0.0 LC, LC7, LP LA-KNP pole 2 2 LA-KN22P A () Cannot be used on contactors : LP4/LP5-Kii0, LP4/LP5-K (2) Cannot be used on contactors : LP4/LP5-K (3) Cannot be used on contactors : LC7/LC8/LP/LP2-K (4) Cannot be used on contactors : LC7/LC8/LP/LP2-Kii0, LC7/LC8/LP/LP2-K Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, 2 A maximum. - Control voltage : c or a V, c V, Uc. - Maximum switching capacity : 250 VA or 50 W. - Operating temperature : C. - Reset time :.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, block per contactor Voltage Type Timing Composition Reference Weight range V s C/O kg c or a On-delay 30 LA2-KT2E c On-delay 30 LA2-KT2U Electronic time delay contact blocks LA2-KT On contactors On reversing contactors LA2-KT LA2-KT Te /9
9 K 3 and 4-pole contactors, reversing and changeover contactors Suppressor modules incorporating LED indicator Mounting Type For voltages: Sold in Unit Weight and connection lots of reference kg Clip-on fixing Varistor c and a 5 LA4-KEB 0.00 on the front of () 2 24 V contactors LC, LC2, LP and LP2 c and a 5 LA4-KEE V LA4-Kiii c and a 5 LA4-KEFC V c and a 5 LA4-KEUG V Diode + a 5 LA4-KCB 0.00 Zener diode (2) 2 24 V a 5 LA4-KCE V RC (3) c 5 LA4-KAU V () Protection by limitation of the transient voltage up to 2 Uc maximum. Maximum reduction of transient voltage peaks. Slight time delay on drop-out (. to.5 times the normal time). (2) No overvoltage or oscillation frequency. Polarised component. Slight time delay on drop-out (. to.5 times the normal time). (3) Protection by limitation of the transient voltage up to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (.2 to 2 times the normal time). Suppressor modules LA4-Ki On contactors On reversing contactors /0 Te
10 K 3 and 4-pole contactors, reversing and changeover contactors Accessories Dimensions : pages /3 and /7 Mounting and marking accessories Description Application Sold in Unit Weight lots of reference kg Mounting For fixing Clip-on LA9-D plates () on ' rail For fixing 0/20 mm DX-AP on 2 ' rails fixing centres Marker Clip-on Onto front of 00 LA9-D holder contactor Clip-in 4 maximum Strips of 25 AB-Ri (2) markers per contactor 0 identical numbers 0 9 Strips of 25 AB-Gi (2) identical capital letters A Z Cabling accessories Description Application Sold in Unit Weight lots of reference kg Paralleling For 2 poles 4 LA9-E links with screw clamp terminals For 4 poles 2 LA9-E with screw clamp terminals Set of 6 power For 3-pole For contactors 00 LA9-K connections reversing with screw contactors for clamp terminals motor control Set of 4 power For 4-pole For contactors 00 LA9-K connections changeover with screw contactor clamp terminals pairs () Order mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor. (2) Complete the reference by replacing the i with the required character. Te /
11 Mini thermal overload relays K thermal overload relays, adjustable from 0. to.5 A, for motor protection; compensated and phase failure sensitive, manual or automatic reset 3-pole relays with screw clamp terminals Direct mounting : under the contactor for versions with screw clamp terminals only; pre-wired terminals, see below. Separate mounting : using terminal block LA7-K0064 (see below). On the front of the overload relay : - selection of reset mode : Manual (marked H) or Automatic (marked A), - red pushbutton : Trip Test function, - red pushbutton : Trip reset, - blue pushbutton : Stop and manual Reset, - yellow trip flag indicator : overload relay tripped. Protection by fuses or by magnetic circuit-breaker type GV2-L, see page /92. Relay Fuses to be used with selected relay Reference Weight setting Maximum rating range Type am gg (BS88) A A A kg Class 0 A (the standard specifies a tripping time of between 2 and 0 seconds at 7.2 In) LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K LR2-K Direct mounting under the contactor 8 = 50 = = 35 = 4xØ /2 Te
12 Mini thermal overload relays K thermal overload relays, adjustable from 0. to.5 A, for motor protection; compensated and phase failure sensitive, manual or automatic reset Accessories for thermal overload relays Description Type of connection Reference Weight kg Terminal block for separate Screw clamp LA7-K clip-on mounting of the overload relay on 35 mm " rail Separate mounting with terminal block LA7-K0064 on 35 mm " rail (AM-DP200 or AM-DE200) c AM- C DP DE Te /3
13 K 3 and 4-pole low consumption contactors for motor control (AC-3) and heating and lighting, etc. (AC-) Control circuit : d.c. a d.c. control contactors () - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil ( Uc), suppressor fitted as standard, consumption.5 W. Motor control Type of Instantaneous Basic reference. Weight in category AC-3 connection auxiliary Complete with code Maximum Standard contacts indicating control opera- power ratings circuit voltage (2) tional of 3-phase current motors 440 V 220 V 380 V 440/500 V 230 V V 660/690 V A kw kw kw N/O N/C kg LP4-K Screw clamp LP4-K060iii LP4-K060iii Faston x 6.35 LP4-K0607iii LP4-K0607iii Solder pins LP4-K0605iii for printed LP4-K0605iii Screw clamp LP4-K090iii LP4-K090iii Faston x 6.35 LP4-K0907iii LP4-K0907iii Solder pins LP4-K0905iii for printed LP4-K0905iii Non Type of Number Instantaneous Basic reference. Weight inductive connection of auxiliary Complete with code loads poles contacts indicating control Cat. AC- circuit voltage (2) θ 50 C Maximum current A N/O N/C kg 20 Screw clamp 3 LP4-K090iii LP4-K090iii LP4-K09004iii LP4-K09008iii Faston x LP4-K0907iii LP4-K0907iii LP4-K090047iii LP4-K090087iii Solder pins 3 LP4-K0905iii for printed 3 LP4-K0905iii LP4-K0900iii LP4-K090085iii () Add-on auxiliary contact blocks and accessories, see pages /6 and /7. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a Code JW3 BW3 EW3 SW3 Contactors LP4-K On panel LA-K 3 /4 Te = 50 = 4xØ4 = 35 = On mounting rail AM-DP200 or AM-DE200 (" 35 mm)
14 K 3 and 4-pole low consumption reversing and changeover contactors for motor control (AC-3) and heating, lighting etc., (AC-) Control circuit : d.c. a d.c. control reversing and changeover contactors () - Compatible with programmable controller outputs. - LED indicator incorporated. - Wide range coil ( Uc), suppressor fitted as standard, consumption.5 W. - Mechanical interlock incorporated. - Pre-wired power circuit connections as standard on screw clamp versions. Motor control Type of Instantaneous Basic reference. Weight in category AC-3 connection auxiliary Complete with code Maximum Standard contacts indicating control opera- power ratings circuit voltage (2) tional of 3-phase current motors 440 V 220 V 380 V 440/500 V 230 V V 660/690 V A kw kw kw N/O N/C kg Screw clamp LP5-K060iii LP5-K060iii Faston x 6.35 LP5-K0607iii LP5-K0607iii Solder pins LP5-K0605iii for printed LP5-K0605iii Screw clamp LP5-K090iii LP5-K090iii Faston x 6.35 LP5-K0907iii LP5-K0907iii Solder pins LP5-K0905iii for printed LP5-K0905iii LP5-K090iii Non Type of Number Instantaneous Basic reference. Weight inductive connection of auxiliary Complete with code loads poles contacts indicating control Cat. AC- circuit voltage (2) θ 50 C Maximum current Reversing contactors LP5-K On panel LA-K 8xØ4 A N/O N/C kg 20 Screw clamp 3 LP5-K090iii (3) LP5-K090iii (3) LP5-K09004iii Faston x LP5-K0907iii LP5-K0907iii LP5-K090047iii Solder pins 3 LP5-K0905iii for printed 3 LP5-K0905iii LP5-K0900iii () Add-on auxiliary contact blocks and accessories, see pages /6 and /7. (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a Code JW3 BW3 EW3 SW3 (3) Warning: this reversing contactor is pre-wired for reverse motor operation. On mounting rail AM-DP200 or AM-DE200 (" 35 mm) 3 = = = 50 = 90 Te /5
15 K 3 and 4-pole low consumption contactors, reversing and changeover contactors Instantaneous and time delay auxiliary contacts Instantaneous auxiliary contact blocks Clip-on front mounting, block per contactor Type of Type of Composition Reference Weight connection contactor N/O N/C kg Screw clamp 3 or 4-pole 2 LA-KN LA-KN LA-KN 0.0 Faston 3 or 4-pole 2 LA-KN x LA-KN LA-KN7 0.0 With terminal referencing conforming to standard EN 5002 Clip-on front mounting, block per contactor Screw clamp 3-pole, 2 LA-KN02M and 9 A LA-KNM pole, 9 A LA-KNP 0.0 Electronic time delay auxiliary contact blocks - Relay output, with common point changeover contact, 2 A maximum. - Control voltage : c or a V, c V, Uc. - Maximum switching capacity : 250 VA or 50 W. - Operating temperature : C. - Reset time :.5 s during the time delay period, 0.5 s after the time delay period. Clip-on front mounting, block per contactor Voltage Type Timing Composition Reference Weight range V s C/O kg LA2-KT2i c or a On-delay 30 LA2-KT2E c On-delay 30 LA2-KT2U Electronic time delay contact blocks LA2-KT On contactor LA2-KT /6 Te
16 K 3 and 4-pole low consumption contactors, reversing and changeover contactors Mounting, marking and cabling accessories Mounting and marking accessories Description Application Sold in Reference Weight lots of kg Mounting For fixing Clip-on LA9-D plates () on ' rail For fixing 0/20 mm DX-AP on 2 ' rails fixing centres Marker Clip-on Onto front 00 LA9-D holder of contactor Clip-in 4 maximum Strips of 25 AB-Ri (2) markers per contactor 0 identical numbers 0 9 DX-AP25 Strips of 25 AB-Gi (2) identical capital letters A Z Cabling accessories Paralleling For 2 poles 4 LA9-E links with screw clamp terminals For 4 poles 2 LA9-E with screw clamp terminals Set of 6 power For 3-pole For contactors 00 LA9-K connections reversing with screw contactors for clamp terminals motor control LA9-E0 Set of 4 power For 4-pole For contactors 00 LA9-K connections changeover with screw contactor pairs clamp terminals () Order mounting plate for fixing a contactor and 2 mounting plates for fixing a reversing contactor. (2) Complete the reference by replacing the i with the required character. On one asymmetrical rail DZ5-MB with 2 clip-on mounting plates LA9-D973 or two mounting plates DX-AP25. 2 x LA9-D973 2 x DX-AP25 DZ5-ME = 35 = 90 5 On printed for reversing contactors or 2 contactors mounted side by side 8,65 === = = = 8, A A A2 A xØ,3 Te /7
Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO
Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating
More informationK-Line Mini - Contactors, Overload Relays and Accessories
K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................
More informationIEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton
K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration
More informationTeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters
Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp
More information7 - Control relays. Control relays. b k control relays
/0 Contents 0 - Control relays Control relays b k control relays v For a.c or d.c control circuit................................. page /4 v For d.c control circuit (low consumption).......................
More informationTeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts
Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationIEC Type Industrial Control Relays Control Relays CA2D and CA3D AC and DC Relays
AC and DC Relays AC Control Relays Type Number Composition Catalog Number Weight of contacts Instantaneous 4 4 CDN40.71/0.320 3 1 CDN31.71/0.320 CDN31 2 2 CDN.71/0.320 2 2 CDC.71/0.320 inc. 1 N/O and 1
More informationTeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor
s TeSys D, -pole changeover contactor pairs for control in category AC-, 0 A Pre-assembled. Pre-wired power connections. For connection by spring terminals. Utilisation category AC- Non-inductive loads
More informationDB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0
DB127250.eps or See page opposite for mounting possibilities according to the contactor type 5/78 References TeSys Instantaneous auxiliary contact blocks Instantaneous auxiliary contact blocks for connection
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationThe technical guide TeSys D
The technical guide TeSys D for power control & protection helping you easily select the right product Catalogue 009 Table of contents TeSys D Contactors TeSys D Contactors Pages Selection guide to Technical
More informationControl relays and plug-in control relays
Selection guide and plug-in control relays Applications EEquipment based on control relays control relays Mini-control relays Control a 24 660 V 2 690 V voltages c 2 440 V 2 250 V Functions Instantaneous
More informationontrol and rotection omponents
ontrol and rotection omponents Chapter B7 Relays TeSys SK, K - For control of TeSys K contactor coils and other devices Type of product Pages TeSys SK, SKE TeSys K Relays TeSys D - For control of TeSys
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationTeSys protection components
Description, characteristics -pole electronic thermal overload, TeSys LR9D0, 0, 08, and LR9D0S DB8880.eps 7 / & 8 Description LR9D0, 0, 08 and self-powered electronic thermal overload are designed for
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationPlug-in relays RH control relays Instantaneous (RHN) and latching (RHK)
Characteristics Instantaneous (RHN) and latching (RHK) Type RHN RHK Environment Classification Standard version EDF, BV, USSR Conforming to standards Standard version IEC 255, NF C 45-25, VDE 435, BS 4794
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More informationOverload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview
Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More informationAllen-Bradley Drives
Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact
More informationControls Contactors and Contactor Assemblies
Dimensional drawings RT10 contactors, -pole RT10 1 contactors, size S00 with surge suppressor, auxiliary switch block and mounted overload relay 4, 8,6 67 99 106 9 ) Lateral distance to grounded components
More informationict contactors EN 61095, IEC 1095 Interference
ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.
More informationAllen-Bradley 700-K40E-DJ
Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode
More informationSIRIUS 3RB2 Solid-State Overload Relays
SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationZelio Relay - plug-in relays 6
Presentation Zelio Relay - plug-in relays or Presentation of the range The RXM miniature relay range comprises: A relays with C/O contacts, 0 A relays with C/O contacts, A relays with C/O contacts and
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More information1 - Control and signalling units
Contents 0 - Control and signalling units Selection guide..............................................page /2. Control and signalling units Ø 8 et 2 b LED pilot lights, type XVL A...................................
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationRUC industrial relays of small dimensions
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Max. breaking capacity
More information40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.
40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More informationRUC industrial relays of small dimensions
with adaptor (V) with adaptor (H) Power relays of general application AC and DC coils Mounting: in sockets; 35 mm rail mount acc. to PN-EN 60715; on panel; PCB Versions: faston 187 (4,8 x 0,5 mm); faston
More informationRUC-M industrial relays for DC loads
Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current Min. breaking capacity
More informationBulletin 817 Thermistor Protection Relay
6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output
More informationMiniature PCB Relays A
SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit
More informationRE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC
Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay
More informationRE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC
Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time
More informationDiscover TeSys U motor starters open version Starter-controller Non-reversing power bases
Discover TeSys U motor starters open version Starter-controller Non-reversing power bases DB0 DB0 LUB, LUB LUB 0, LUB 0 Two types of bases are available, each in two versions: b LUB, LUB Standard power
More informationSPM Series. Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name
More information3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...
/ Contents - Selection guide............................................. page / for discrete signals # Electromechanical interface modules........................... page / # Slim electromechanical interface
More informationNC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size
R C US LISTED EU Germany Czech Ukrain South Africa USA NC Contactor, 5~30A. General. Certificates: CE, VDE, ESC, UKRTEST, RCC, UL.. Electric ratings; AC50/0Hz, up to 000V, up to 30A;.3 Application: remote
More informationTeSys SK, K, D. Technical Data for Designers. Contents
Control relays TeSys SK, K, D Tehnial Data for Designers Contents TeSys SK: > harateristis...b/ and B/1 > dimensions...b/1 > shemes...b/1 TeSys K: > harateristis...b/18 and B/19 > dimensions...b/0 > shemes...b/1
More informationSPM Series Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More information4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current
Quattro-Relais Quattro Relay 4 Quattro Relay 4A4 Standard type / With LED and protection diode on request Quattro-Relais Order Code Order Code Quattro Relay 4 A 4 4 V DC N Type of relay Quattro Relay 4
More informationMODULES FOR SAFETY AND MONITORING
MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,
More informationRW-E. Overloads. Solid-State Overload Relays. Standard Features
RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be
More informationTeSys contactors 5. Selection 5. For utilisation category AC-3. Operational current and power conforming to IEC (θ y 60 C) Contactor size
Selection TeSys contactors For utilisation category AC- Operational current and power conforming to IEC (θ y 0 C) Contactor size Maximum operational current in AC- Rated operational power P (standard motor
More informationRUC industrial relays of small dimensions
RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching
More informationRPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED
Characteristics power plug-in relay - Zelio RPM - 4 C/O - 230 V AC - 15 A - with LED Complementary Shape of pin [Ui] rated insulation voltage Main Range of product Series name Product or component type
More informationZelio Relay - plug-in relays
Presentation Presentation offer the advantages of compact size and modular design: their slim width ( mm) saves space when mounting on a rail at the back of an enclosure. RSL relays are available in two
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationMotor Control Products Selection Guide
MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors
More informationRE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz
Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay
More informationCONTA-ELECTRONICS. Fuse, component, diode and indicator modules
Fuse, component, diode and indicator modules In the passive electronics sector, CONTA-CLIP offers a large variety of module types which support fast, secure, and compact functionality. These modules can
More informationTeSys protection components
GV ME GV ME0 Motor circuit-breakers from 0.0 to kw / 00 V, with screw clamp terminals GV ME with pushbutton control 00/ V 00 V 0 V () () () () Id ± 0 % kw ka % kw ka % kw ka % A A k 0. 0.. GV ME0 0.0 0.0
More informationTimers & control relays
7% Timers & control relays J PCB mount relays Finder J-1 3 Plug-in relays Finder J-2 8 Power relays Finder J-7 Stepping relays Finder J-9 Modular contactors Finder J-10 Relay interface modules Finder J-11
More informationATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW
Characteristics soft starter for asynchronous motor - ATSU01-9 A - 200..480V - 1.5..4 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Product or component
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationSolid-state relay (SSR) advantages. Solid-state relays
Electromechanical relays Solid-state relays, or C/O,, or C/O C/O or N/O 0 A A 0 A A 0... A 0... A DIN rail or panel DIN rail DIN rail or panel Panel RUM RPM RPF ABS SSRD SSRP to to 0 to to to to Solid-state
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationRM4TA32 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationPower Electronics. Semiconductor relay / - contactor
Power Electronics Semiconductor relay / - contactor PH 9260 POWERSWITCH 0247349 Semiconductor relay PH 9260.91 Semiconductor contactor PH 9260.91/000/01 AC semiconductor relay / -contactor According to
More informationCircuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V
CP3E, 32E, 33E, 34E CP3V, 32V, 33V, 34V CP-E and CP-V circuit protectors 250V AC 0.05A to 30A 65V DC 0.05A to 30A Description CP-E, CP-V circuit protectors have been specially developed for computers,
More informationRM4TR31 three-phase network control relay RM4-T - range V
Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range
More informationSolid State Remote Power Controller E /627
Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves
More informationNew Solutions. for AC Motor Starters
ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationPush buttons and selectors
Accessories and spare parts 8 LM2T A130 8 LM2T A140 8 LM2T A185 8 LM2T AL... Order code Description Qty per Wt 8 LM2T A12❶ Coloured diffuser for 10 0.001 double touch buttons 8 LM2T A130 Threaded plug
More informationSwitchgear 1.1. CONTACTORS - Installation. Page 1.2. Page 1.2. CONTACTORS - Mini. Page POLE RELAY. Page 1.3. CONTACTORS - Standard Frame
Switchgear CONTACTORS Installation Page 1.2 CONTACTORS Mini Page 1.2 4 POLE RELAY Page 1.2 CONTACTORS Standard Frame Page 1.3 CONTACTORS Large Frame Page 1.4 OVERLOADS Thermal Page 1.5 CONTROL RELAYS Industrial
More informationRE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O
Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range Sep 23,
More informationATS01N206RT soft starter for asynchronous motor - ATS01-6 A V
Characteristics soft starter for asynchronous motor - ATS01-6 A - 460..480 V Price* : 152.00 GBP Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationRM84 miniature relays
RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to
More informationThree-phase monitoring relay
2CDC 251 044 F0t08 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationDatasheet - SLB 200-C04-1R
14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationUniversal Motor Controller UMC22-FBP. High-grade Motor Protection and Control
Universal otor Controller UC-FBP High-grade otor Protection and Control The FieldBusPlug concept This new ABB product family is a communication device range with switching and automation components which
More informationElectronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers
More informationRM4JA01F current measurement relay RM4-J - range ma V AC
Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in
More information