User's Manual. Professional IR Thermometer with USB
|
|
- Emil Russell
- 6 years ago
- Views:
Transcription
1 User's Manual Professional IR Thermometer with USB Please read this user's manual thoroughly before using this unit and keep it properly for your future reference.
2
3 Contents 1. Introduction Features Application Safety Field of View Specifications Meter Description LCD Display Description Operating Instruction Notes Accessories... 17
4 1. Introduction Congratulations on your purchase of our professional non-contact infrared thermometers. These units can provide fast, easy and accurate temperature readings. With the non-contact (infrared) technology, they can be used to measure the surface temperature of hard-to-reach objects like electrified equipment or moving objects, without any damage or pollution to them. 2. Features Fast and easy measurement Precise non-contact measurement The built-in laser pointer increases the target accuracy Adjustable emissivity: 0.1~1.0 MAX, MIN, DIF, AVG Record Backlight LCD display Automatic measurement range selection with resolution 0.1 / PC real-time monitoring and recording High/Low Alarm 1
5 Automatic trigger off and power off 2
6 3. Application These units are widely used in Food preparation, Safety and Fire inspection, Plastic molding, Asphalt, Marine, Printing ink and dryer temperature, Diesel and Fleet maintenance. 4. Safety Use extreme caution when the laser beam is turned on. Do not point the beam toward anyone or any animals. Do not allow the beam to strike the eye from a reflective surface. Do not use the laser near explosive gases. Safety Symbol 3
7 Comply with EMC 4
8 5. Field of View The meter's field of view is 50:1, for example, if the meter is 50 inches from the target spot, the diameter of the target must be at least 1 inch. Other distance ratios are show below in the field of view diagram. 5
9 6. Specifications Range Accuracy -50~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~0 /-58~32 :±4 0~500 /32~932 :1.5%±2 /3.6 Above 500 /932 :2% ±2 /3.6 Optical Resolution 50:1 Emissivity Adjustable: 0.10~1.0 Resolution 0.1 (0.1 ) < 1000;1 (1 ) > 1000 Response Time Spectral Response Data recording Polarity Display Diode Laser Automatic Power Off Operating Temp. Storage Temp. Relative Humidity Power Supply Weight Dimensions(L*W*H) <250ms 8~14um PC real-time monitoring and recording Auto display, "-" indicates negative, while positive with no sign. Output<1mW,630~670nm, class 2(Ⅱ) Meter shuts off automatically after 20 seconds 0 ~50 (32 ~122 ) -20 ~60 (-4 ~140 ) Operating:10 to 95%R;Storage:<80%RH 9V battery 290g 191.5*126*60mm 6
10 7. Meter Description 1 LCD Display 2 Shift Down Button 3 Laser Pointer/ Backlit Button 4 Shift Up Button 5 Function Button 6 Tripod Nut 7 Battery Compartment 8 Trigger Button 9 Open Battery Compartment Button 10 USB interface 11 IR Sensor 12 Laser Pointer 7
11 8. LCD Display Description 1 Data Hold Icon 2 Measurement Icon 3 Emissivity Icon 4 Laser Icon 5 Backlit Icon 6 Temperature Unit( / ) 7 Measurement Readings 8MAX/MIN/AVG/DIF display area 9 DIF Icon 10 AVG Icon 11 High Alarm Value 12 Max/Min Icon 13 Low Battery Icon 14 Low Alarm Icon 15 High Alarm Icon 16 USB Connection Icon 8
12 9. Operating Instruction A. Operating steps: 1 Hold the meter by its handle grip and point it toward the surface to be measured. 2 Pull and hold the Trigger to turn the meter on, the "SCAN" icon will appear and begin testing. 3 The surface temperature being tested will be displayed on the LCD screen. 4 Release the trigger, the "HOLD" icon will appear, and the reading will be held for several seconds. 5 The meter will automatically shut off after 20 seconds. Measurement Note:If the meter used in an ambient temperature with wide temperature change, awaiting it at least 30 minutes to adjust it. The laser is designed for aiming only; it can be shut off while operating in short distance to save the battery. B. Button Function 1 / button: In Measurement Mode, press button and to switch the temperature unit or. 2 Laser pointer/backlight button: In Measurement Mode, press 9
13 button to turn on/off laser pointer, In HOLD Mode, press button to turn on/off backlight. 3 During measuring,press button to display MAX, MIN, AVG, DIF, High/Low Alarm readings. During measuring, press button until icon flashes on the screen, then loose button enter into Emissivity Mode, press button and to adjust emissivity value, then keep pressing button return to the normal measurement mode (After entering Emissivity Mode, press button can set the High/Low alarm value ). 10
14 C. PC Software operating 1 Software installation Insert the CD into the CD-drive, double-click the icon, follow the installation tips to install software. 2After installed the software successfully, click the desktop shortcut icon to open the software, see the software interface as below: 3 Connect the meter with PC via USB cable, then power on the meter, the software will automatically connect the meter and conduct real-time data transmission. 4Toolbar introduction: File menu Pull-down menu see as below: 11
15 Open: Open the saved data file Save: Save data Print: Printing charts Exit: Exit the software View menu Pull-down menu see as below: Zoom In: Zoom in the graph curve Zoom Out: Zoom out the graph curve Zoom CLS: Graph curve returns to the normal ratio Y Grid: Y Grid of the graph X Grid: X Grid of the graph Cursor Cross: data the cursor points Unit: / selection 12
16 Control menu Pull-down menu see as below: Start: Start recording,set info see the figure below: Stop: Stop recording Connect: Connection establishment Disconnect:Disconnect connection 5 Short-cut icon explanation :Save :Open file :Disconnect connection :Zoom in graph curve :Connection establishment :Start recording :Zoom out graph curve :Graph curve returns to the normal ratio :Graph curve background color :Data curve color D. Battery Replacement 13
17 1 When the low battery icon appears, replace the meter's battery. 2 Open the battery compartment, replace the 9V battery and close the battery compartment. 14
18 10. Notes (1) Work Principle The infrared thermometer is designed for measuring surface temperature of an object. The optical sensor can emit, reflect and transmit energy, which is collected and focused on a detector, then translate it into the temperature reading by electronics and displayed on the LCD screen. The laser is used for aiming the target object only. (2) Field of View The object under test should be larger than the spot size calculated by the field of view diagram. The smaller the target object is, the closer the meter should be to it for accurate measuring. When accuracy is critical, make sure the target is at least twice as large as the spot size. (3) Distance & Spot Size As distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. (4) Locating a hot spot To find a hot spot, first aim the thermometer to the outside of target area, then scan across in an up and down motion until 15
19 the hot spot is located. (5) Notice Not recommend for measuring shiny or polished metal surfaces like stainless steel, aluminum, etc. Do not make measurement through transparent surface such as glass. If the surface of the object under test is covered with frost, oil, grime, etc., clean it before taking measurement. (6) Maintenance Do not use volatile liquids to clean the unit, wipe it with dry soft cloth. Do not disassemble the unit, repair it by qualified personnel Do not immerse it in water. Do not store it in high temperature or humidity. (7) Emissivity Most (90%) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). 16
20 11. Accessories 1 User's Manual 2 9V Battery 3 USB Cable 4 PC Software 17
21 Emissivity Table Substance Thermal emissivity Substance Thermal emissivity Aluminium 0.30 Glass 0.90 to 0.95 Asphalt 0.95 Iron oxides 0.78 to 0.82 Concrete 0.95 Lacquer 0.80 to 0.95 Leather 0.95 Plastic 0.85 to 0.95 Ceramic 0.95 Paper 0.70 to 0.94 Copper 0.50 Sand 0.90 Brick 0.90 Rubber 0.95 Carbon 0.85 Timber 0.94 Fatlute 0.94 Textiles 0.94 Frozen food 0.90 Lead 0.50 Hot food 0.93 Marble 0.94 Ice 0.98 Cloth(black) 0.98 Snow 0.90 Plaster 0.8 0to 0.90 Human skin 0.98 Water 0.93
22
Infrared Thermometer User Manual
Infrared Thermometer User Manual Contents 1. Introduction... 2 2. Features... 2 3. Application... 2 4. Safety...3 5. Field of View...4 6. Specifications... 5 7. Meter Description...6 8. LCD Display Description...6
More informationHeavy Duty Psychrometer + IR Thermometer Model HD500
User Guide Heavy Duty Psychrometer + IR Thermometer Model HD500 Introduction Congratulations on your purchase of the Extech HD500 Psychrometer. This handheld meter measures and displays Air Temperature,
More informationBedienungsanleitung Users Manual Mode d emploi. IR-Thermometer Pocket Thermomètre digital FIRT 550-Pocket
Bedienungsanleitung Users Manual Mode d emploi IR-Thermometer Pocket Thermomètre digital FIRT 550-Pocket 1 2 FRONT PANEL 1) IR Sensor 2) LCD display 3) button / laser pointer 4) button / illumination 5)
More informationThermometers. Operation Manual
Thermometers Operation Manual 1 INTRODUCTION Thank you for purchase of the this Thermometer. This device is a non-contact(infrared) thermometer and contact(probe) thermometer.to use the non-contact(infrared)
More informationUSER GUIDE. Differential Thermometer Datalogger. Model HD200
USER GUIDE Differential Thermometer Datalogger Model HD200 Introduction Congratulations on your purchase of the Extech HD200 Differential Thermometer Datalogger. The HD200 supports differential temperature
More informationUser's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model : BST-AFM05
User's Manual CFM/CMM Thermo Anemometer + InfraRed Thermometer Model : BST-AFM05 Introduction BESANTEK BST-AFM06 CFM/CMM Thermo Anemometer with InfraRed Thermometer measures Air Velocity, Air Flow (volume),
More informationUser's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200 UNITS NEXT AREA RECALL. cf m/cmm Anemometer Thermometer AN200
User's Manual CFM/CMM Thermo Anemometer + InfraRed Thermometer Model AN200 cf m/cmm Anemometer Thermometer AN200 UNITS NEXT AREA RECALL PROBE TEMPERATURE Introduction Congratulations on your purchase of
More informationUser's Manual. CFM/CMM Thermo Anemometer + InfraRed Thermometer. Model AN200. Anemometer Thermometer AN200 UNITS NEXT AREA RECALL.
User's Manual CFM/CMM Thermo Anemometer + InfraRed Thermometer Model AN200 cf m/cmm Anemometer Thermometer AN200 UNITS NEXT AREA RECALL PROBE TEMPERATURE Introduction Congratulations on your purchase of
More informationHigh Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting
High Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting DHS235XEL WD1048 Rev A 04/10/10 Table of Contents 1. Product Introductions... 1 1-1 Features...
More informationInfrared Thermometer Remote Temperature Measurement ( Non-Contact ) TES-1326S INSTRUCTION MANUAL
Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) TES-1326S INSTRUCTION MANUAL INTRODUCTION The hand-held Infrared Thermometer is easy to operate. Furthermore, the backlight illumination
More informationElcometer 214L. Infrared Digital Thermometer. Operating Instructions
English Elcometer 214L Infrared Digital Thermometer Operating Instructions English The Elcometer 214L Infrared Digital Thermometer has been tested in accordance with EU regulations governing electro-magnetic
More informationModel R2050. Thermal Imager, 80 x 80 Pixels. Instruction Manual.
Model R2050 Thermal Imager, 80 x 80 Pixels Instruction Manual 1-877-849-2127 info@reedinstruments.com Table of Contents Safety... 3 Features... 4 Specifications...5-6 Instrument Description... 7 Operating
More informationI/R Thermometer Gun 8:1
I/R Thermometer Gun 8:1 800101, 800102 INSTRUCTION MANUAL SPER SCIENTIFIC Contents Page 1. INTRODUCTION...2 2. SAFETY SPECIFICATIONS...3 3. DISPLAY AND BUTTON LOCATIONS...4 4. BATTERY REPLACEMENT...5 5.
More informationUser Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model
User Manual Dual-Input Data Logging Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-92 Thermistor Meter Model 20250-94 RTD Meter Model 20250-96 THE STANDARD
More informationProfessional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand
User Manual Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand with NIST-Traceable Calibration Model 20250-20 Enter REC DIF THE STANDARD IN PRECISION
More informationHow to Evaluate Thermography Cameras
How to Evaluate Thermography Cameras Art Stout VP, Business Development Electrophysics Corporation 800-759-9577 Astout@electrophysics.com Today there are more choices then ever before when evaluating thermography
More information200 C ~ 1850 C (392 F ~ 3362 F) INFRARED THERMOMETER 200 C ~ 2200 C (392 F ~ 3992 F) OPERATION MANUAL
INFRARED THERMOMETER 200 C~1850 C(392 F~3362 F) 200 C~2200 C(392 F~3992 F) INFRARED THERMOMETER 200 C ~ 2200 C (392 F ~ 3992 F) INFRARED THERMOMETER 200 C ~ 1850 C (392 F ~ 3362 F) OPERATION MANUAL K user's
More informationINFRARED THERMOMETER USER S MANUAL
INFRARED THERMOMETER USER S MANUAL Laser Targeting Ring TS05 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TABLE OF CONTENTS
More informationTrue RMS Multimeter with IR Thermometer
Owner's Manual True RMS Multimeter with IR Thermometer Model No. 82024 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationExtech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide
Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer User's Guide Introduction Congratulations on your purchase of the Extech EX820 True RMS 1000A Clamp Meter. This meter measures AC/DC Voltage,
More informationTrue RMS Multimeter with IR Thermometer
User Guide True RMS Multimeter with IR Thermometer Extech EX210T Introduction Thank you for selecting the Extech EX210T True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current,
More informationUser Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer
User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EX820
More informationInfrared thermometers with visible laser for measuring surface temperature without contact
PCE-8xx PCE-IR 425 Infrared thermometers with visible laser for measuring surface temperature without contact Infrared thermometer with laser pointer and an input for type-k thermoelements Infrared thermometers
More informationController LED ADT MP3-20
Manual Controller LED ADT MP3-20 Table of contents 1. Safety instructions... 3 1.1. For safe and efficient operation... 3 2. Introduction... 4 3. Key functions... 4 4. Technical data... 5 5. Dimensions...
More informationLDM M LASER DISTANCE MEASURER
LDM120 120M LASER DISTANCE MEASURER INSTRUCTION MANUAL SAFETY Read the following safety instructions before attempting to operate this product. SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE.!
More informationIndoor Air Quality Meter/Datalogger
User Manual Indoor Air Quality Meter/Datalogger Model EA80 CC Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EA80 Indoor Air
More informationHDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual
HDT-318 Thermo-Hygrometer with Data Logger (Air Humidity/Temperature) Instruction Manual CONTENTS 1. SAFETY INFORMATION... 2 2. GENERAL DESCRIPTION... 2 3. FEATURES... 2 4. SPECIFICATIONS... 3 5. SYMBOL
More informationUser Guide. Indoor Air Quality Meter/Datalogger. Model EA80
User Guide Indoor Air Quality Meter/Datalogger Model EA80 Introduction Congratulations on your purchase of the Extech EA80 Indoor Air Quality Meter. This meter measures Carbon Dioxide (CO 2, ppm) levels,
More informationCENTER 521 INSTRUCTION MANUAL 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S)
CENTER 521 INSTRUCTION MANUAL 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) CONTENTS 1. GENERAL DESCRIPTION... 1 2. SAFETY INFORMATION... 2 3. FEATURES... 2 4. SPECIFICATIONS...
More information400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623
User's Guide 400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623 Introduction Congratulations on your purchase of this Extech EX623 True RMS Clamp Meter. This meter measures AC Current, DC
More informationManual Sound level indicator PCE-353
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business
More informationHH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual
HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual CONTENTS 1. GENERAL DESCRIPTION... 2 2. SAFETY INFORMATION... 2 3. FEATURES... 2 4. SPECIFICATIONS...
More informationTEST & MEASUREMENT NEW NEW NEW FULL RANGE OF TEST & MEASUREMENT DEVICES. micro DM-100. micro CM-100. micro HM-100. micro LM-100 Laser Distance Meter
TEST & MEASUREMENT micro DM-100 Digital Multimeter Drop- & Waterproof micro CM-100 Digital Clamp Meter Versatile, 10 Functions micro HM-100 Temp. Humidity Meter Accurate Measurements FULL RANGE OF TEST
More informationPersonal Sound Level Meter
User's Guide Personal Sound Level Meter Model SL10 Introduction Congratulations on your purchase of the Extech SL10 Personal Sound Level Meter. The SL10 measures and displays sound pressure levels in db
More informationDigital Thermometer MEM. PC-Link READ
Digital Thermometer MEM PC-Link READ CONTENTS Digital Thermometer 1. Safety Information...1 2. Product Overview...3 3. Recognize Meter..... 4 3.1 Component...4 3.2 Display...5 3.3 Keys Description...6
More informationManual Infrared camera PCE-TC 30
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA Tel: 410-387-7703 Fax: 410-387-7714 info@pce-americas.com www.pce-instruments.com/us www.industrial-needs.com PCE Instruments UK Ltd. Units
More information4 Channel Datalogging Thermometer. Instruction Manual
4 Channel Datalogging Thermometer 800024 Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 4 MATERIALS SUPPLIED... 4 FRONT PANEL DESCRIPTION... 5 LCD DISPLAY... 6 SET UP... 7 MEASUREMENT
More informationVORON. Concealed micro video cameras detector. Version: March 2013 OPERATION MANUAL. TS-Market
VORON Concealed micro video cameras detector OPERATION MANUAL Version: March 2013 TS-Market Contents Purpose...3 Main features...3 Precautions...4 Description and specifications...5 Overlook...5 Technical
More informationIR Crop Temperature/ External Soil Temperature Meter PRODUCT MANUAL
IR Crop Temperature/ External Soil Temperature Meter PRODUCT MANUAL Item # 2958 CONTENTS Specifications 2 Description 3 Operation 4 Maintenance 7 Warranty 8 CE Declaration of Conformity 8 Thank you for
More informationFengMi Wemax One Laser Projection TV
FengMi Wemax One Laser Projection TV User`s Manual About electrical ground Transportation Use this device only with a compulsory grounding condition. It is recommended that you use the original packaging
More informationUser's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer
User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non-Contact IR Thermometer, Model
More informationUSER GUIDE FLIR TG165
USER GUIDE FLIR TG165 Imaging IR Thermometer Table of Contents 1 Disclaimer... 4 1.1 Copyright... 4 1.2 Quality Assurance... 4 1.3 Documentation... 4 1.4 Disposal of Electronic Waste... 4 2 Safety... 5
More informationUSER MANUAL FLIR TG165
USER MANUAL FLIR TG165 Imaging IR Thermometer Table of Contents 1 Disclaimer... 4 1.1 Copyright... 4 1.2 Quality Assurance... 4 1.3 Documentation... 4 1.4 Disposal of Electronic Waste... 4 2 Safety...
More informationUser's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer
User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX840 CAT IV True RMS 1000A Clamp Meter. This meter measures
More informationDigital UVC Light Meter
UV512C USER S MANUAL Digital UVC Light Meter Thank you for purchasing this Digital UVC Light Meter. Read through this instruction manual before operating the unit. Please also store and retain this instruction
More informationSP-L51. Portable Thermal Printer. User s Manual VER 1.00
SP-L51 Portable Thermal Printer User s Manual VER 1.00 1 Content NOTICE... 3 Notice of Safety... 3 Notice of Using... 3 Notice of Storing... 3 Chapter 1 Outer Appearance and Model No.... 4 1.1 Outer Appearance...
More informationRS Stock No Instruction Manual RS Input Data Logging Thermometer
RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2
More informationtable of contents Measurement instruments Scales & Balances Sound Level Meters Temperature Meters 2-9 Air Flow Meters 42-43
table of contents Measurement instruments Temperature Meters 2-9 Sound Level Meters 40-41 Humidity- / Moisture Meters 10-15 Air Flow Meters 42-43 Distance Meters 44 Data Loggers 16-17 Gas Meters 45-49
More informationMTP INSTRUCTION MANUAL
MTP INSTRUCTION MANUAL Wireless Electricity Monitor Model MTP-3100 MTP Instruments Inc. Table of Content 1. Introduction Page 1 2. Safety and Maintenance Information Page 1 3. Features / Specifications
More informationInstruction Manual Ultrasonic Thickness gauge DC3020
Instruction Manual Ultrasonic Thickness gauge DC3020 V 7.11 CONTENTS 1.General Description... - 1-2.Technical Specifications... - 1-3. Standard Delivery... - 2-4. Overview the Display Unit... - 2-5. Keypad
More information============================================================ ============================================================
============================================================ ============================================================ SCT HANDHELD INFRARED THERMOMETERS Handheld The Models SCT620, SCT622, SCT623 are
More informationTIF785 Photo Tachometer
TIF785 Photo Tachometer Owner s Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Safety Precautions CAUTION: This is a Class
More informationPortable Document & Image Scanner. User s Manual
Portable Document & Image Scanner User s Manual Table of Contents 1. Precaution. 2 2. Preparation..5 Standard Accessories 5 Part Names & Functions..6 3. key features..... 7 4. Status Icons Explanations.....8
More informationUser Manual. Hand-held Laser Distance Meter
User Manual Hand-held Laser Distance Meter Safety regulations Please read the safety regulations and operation guide carefully before operating. Please read all of the operational guide and safety regulations
More informationToolSmart Digital Moisture Meter
ToolSmart Digital Moisture Meter Model: TS06 User s Manual ToolSmart Digital Moisture Meter r Model:TS06 Overview TS06 ToolSmart Digital Moisture Meter measures the moisture content by detecting the electrical
More informationUser Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model
User Manual Single-Input Thermometers with NIST-Traceable Calibration Thermocouple Meter, Type J/K/T Input Model 20250-91 Thermistor Meter Model 20250-93 RTD Meter Model 20250-95 THE STANDARD IN PRECISION
More informationSelf-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual
1676H-English 10/3/08 10:46 AM Page 1 Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No. 40-6602 Instruction Manual Congratulations on your choice of this Self-Leveling Cross Line Laser
More informationDCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355
THE SEEKER 200 SERIES & THE SEEKER 300 SERIES VIDEO INSPECTION SYSTEMS DCS200 (shown) DCS300 (shown) DCS200/DCS200-09/DCS200-05 DCS300/DCS300-09/DCS355 USER S MANUAL Please read this manual carefully and
More informationVideo Borescope Inspection Camera
Owner's Manual Video Borescope Inspection Camera Model 82027 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationUSER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at
USER MANUAL Light Meter Model LT510 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Model LT510. The LT510 measures light intensity in foot-candles
More informationDeluxe In/Out Remote Thermometer with Trend Chart
Deluxe In/Out Remote Thermometer with Trend Chart MODEL: JTR-168LR USER'S MANUAL INTRODUCTION Congratulations on your purchase of the JTR-168LR Deluxe In/ Out Remote Thermometer. The basic package comes
More informationAutoranging Multimeter plus IR Thermometer Extech 450 Patented
User's Guide Autoranging Multimeter plus IR Thermometer Extech 450 Patented Introduction Congratulations on your purchase of the Extech 450 (part number EX450) Autoranging Multimeter plus IR Thermometer.
More informationUser's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented
User's Guide 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your
More informationUSER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at
USER MANUAL Hygro-Thermometer Model RHT510 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Model RHT510. This hand-held device measures Relative
More informationUSER GUIDE. Coating Thickness Tester. Model CG104
USER GUIDE Coating Thickness Tester Model CG104 Introduction Thank you for selecting the Extech Instruments CG104 Coating Thickness Tester. The CG104 is a portable meter designed for non invasive coating
More informationPosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.
PosiTector DPM Dew Point Meter INSTRUCTION MANUAL v. 2.0 Simple. Durable. Accurate. Introduction The Dew Point Meter is a hand-held, electronic instrument that measures, calculates and records climatic
More informationENGLISH. User manual
ENGLISH User manual Copyright HT ITALIA 2015 Version EN 2.00-15/09/2015 Table of contents: 1 PRECAUTIONS AND SAFETY MEASURES... 2 1.1 During use... 2 1.2 After use... 2 2 GENERAL DESCRIPTION... 3 3 PREPARATION
More informationTC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2.
OFFSET SETUP READ REC HOLD TC2100 Digital Thermometer User s Manual T1 T2 K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN K INTERVAL hour:min T1 T2 : F CAL min:sec C POWER MAX AVG MIN HOLD SETUP THERMOMETER
More informationUser Manual GBS-1269BT. Body Scale 4.0. version:1.0. Distributed by: Informed Clinical Sciences Corporation 1 Joy Street, Boston, USA MA 02108
version:1.0 User Manual GBS-1269BT Body Scale 103 lbs Thank you very much for selecting the IC Sciences WeighWise Body Scale GBS-1269BT. TM 4.0 Please read the user manual carefully and thoroughly to ensure
More informationExtech EX845 True RMS 1000 Amp Clamp Meter with Bluetooth
SEND User's Guide Extech EX845 True RMS 1000 Amp Clamp Meter with Bluetooth Patented Introduction Congratulations on your purchase of the Extech EX845 CAT IV True RMS 1000A Clamp Meter. This meter is supplied
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationInstruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,
4411H-English_Manuals 3/11/11 1:13 PM Page 1 Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos. 40-6526, 40-6529, 40-6544 Instruction Manual Congratulations on your choice of
More informationTrue RMS Multimeter with IR Thermometer
User Manual True RMS Multimeter with IR Thermometer Model EX570 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EX570 True RMS
More informationContents. 1. Safety information 1 2. Description 2 3. Specifications 6 4. Operating instruction 8 5. Accessories 12
13 4.12 Battery replacement If the sign appears on the LCD display, it indicates that the battery should be replaced. Turn the unit off. Remove the battery cover. Replace the exhausted battery with a new
More informationFluke Ti30 Thermal Imager
Complete imaging solution Lowest cost of ownership Designed for predictive maintenance Fluke Ti30 Thermal Imager Everything needed for everyday imaging. Fluke Ti30 Thermal Imager Unbeatable solution for
More informationUser Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model
User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Single-Input Thermometers with NIST-Traceable Calibration Thermocouple
More informationManual Handheld Rotation Meter PCE-155
PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From Outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us PCE Instruments UK Ltd. Units
More informationUSER GUIDE Turbidity Meter Model TB400
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 USER GUIDE Turbidity Meter Model TB400 Visit us at www.testequipmentdepot.com Introduction Congratulations on your purchase
More informationHandheld Thermography Camera. User Manual UD05641B COPYRIGHT 2017 Hikvision. ALL RIGHTS RESERVED
Handheld Thermography Camera User Manual. UD05641B 0100001070612 COPYRIGHT 2017 Hikvision. ALL RIGHTS RESERVED User Manual Handheld Thermography Camera User Manual COPYRIGHT 2017 Hangzhou Hikvision Digital
More informationFluke Ti30 Thermal Imager. Provided by Everything needed for everyday imaging. Complete imaging solution. Lowest cost of ownership
Provided by www.aaatesters.com Complete imaging solution Lowest cost of ownership Designed for predictive maintenance Fluke Ti30 Thermal Imager Everything needed for everyday imaging. Lowest ownership
More informationManual. Infrared cameras. Contour M
Manual Infrared cameras Contour M Content Content... 2 Safety requirements... 3 About... 4 Operation... 5 The Maintenance instruction... 7 Spectral sensitivity... 7 Power density... 8 Technical information...
More informationSoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 TRIPLETT SoniChek MC Mini Sound Level Meter C Weighted Instruction Manual 84-888 4-10 Visit us at www. I. Safety information
More informationUser Guide True RMS Multimeter Extech EX205T
User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging
More informationNL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.
www.lightware.co.za info@lightware.co.za The InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement. Able to measure to any solid surface, at any angle,
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationINSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs
INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,
More informationUser's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented
User's Guide Digital Multimeter plus IR Thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Extech 450 Patented Introduction
More informationPROTIMETER. TimberMaster. Protimeter Moisture Meter (BLD5605, BLD5609, BLD5605-SW, BLD5609-SW) Instruction Manual. Amphenol.
PROTIMETER TimberMaster Protimeter Moisture Meter (BLD5605, BLD5609, BLD5605-SW, BLD5609-SW) Instruction Manual Amphenol Advanced Sensors INS5605-EN Rev. B October 2017 1 Safety Considerations Caution
More informationUSER GUIDE. Waterproof Borescope. Models BR300 and BR350
USER GUIDE Waterproof Borescope Models BR300 and BR350 Introduction Thank you for selecting the Extech Instruments Model BR300/BR350 Waterproof Borescope. The Waterproof Borescope can be fully immersed
More informationThanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference.
CONTENTS Thanks for you purchasing of this product. Please kindly read this user manual and keep it carefully for reference. 01Read This First...01 Product Information...01 Standard Package Contents...02
More informationData Sheet: LDS 1367 Date:
Product: Electronic Digital Measuring Set Page 1 of 5 Digital Caliper and Electronic Micrometer Set Set contains: 1 x Electronic Caliper: 150mm/6 1 x Electronic Micrometer: 0-25/0-1 mm Housed in a fitted
More informationUSER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A
USER MANUAL True RMS Multimeter plus IR Thermometer Extech EX470A Introduction Congratulations on your purchase of the Extech EX470A True RMS Autoranging Multimeter plus IR Thermometer. This meter measures
More informationDigital Viewer II TM Digital Microscope User s Manual
Digital Viewer II TM Digital Microscope User s Manual Welcome Thank you for choosing Digital Viewer II TM digital microscope! The Digital Viewer II TM digital microscope is an exciting new device to clear
More informationManual SOUND LEVEL METER PCE-322 A
www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk
More informationData Logger / K,J,E,T, Type THERMOMETER SE-378
378 Data Logger / K,J,E,T, Type THERMOMETER SE-378 SE-378 Data Logger THERMOMETER 378-00 JAN. 2013 CONTENTS TITLE PAGE 1. General Description... 1 2. Safety Information... 1 3. Feature... 1 4. Specifications...
More informationDual Type Coating Thickness Tester LZ-990. Operating Manual
Dual Type Coating Thickness Tester LZ-990 Operating Manual Coating Thickness Tester Safety Precautions The Coating Thickness Tester may cause damage to objects being handled if the precautions are not
More informationThermocouple Thermometers
Thermocouple s, Datalogger, Printer Extech offers a selection of thermometers with datalogging and printing capabilities for data storage analysis and report generation. Featuring Model HD200 Dual Input
More information1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.
CONTENTS TITLE PAGE 1. Introduction.. 1 2. Specifications... 1 3. Symbol Definition and Button Location... 2 4. Operation Instructions.... 3 4.1 Power-Up...3 4.2 Connection of the Temperature Probe...
More informationDELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER S MANUAL
DELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER S MANUAL DWS350SSQ PPlease read this manual carefully and thoroughly before using this product. INTRODUCTION Thank you for purchasing General
More information