1 32 Catalog 10 Bus Connectors Repeater Active Dropcable Terminal Block DP/DP Coupler Ethernet Gateways OPC Server Systeme Helmholz GmbH Großenseebach Phone: Fax: Internet:

2 Catalog EasyConnect -Connector, 90 Metalized housing No loosable parts EasyConnect technology Visual connection control Integrated terminating resistor 90 cable outlet Small housing EasyConnect connector The new EasyConnect connector from the Systeme Helmholz GmbH rounds off the range of bus connector products excellently. The new EasyConnect connectors feature quick-connect technology, making the stripping of bus conductors superfluous. The bus connectors are used to connect a node to the line. The connector is quick to install and has a metalized housing and integrated terminating resistors. The Systeme Helmholz GmbH offers the new EasyConnect connector with a perpendicular cable outlet. Correct connection of the cable can quickly be checked visually even after installation. Find a list of released cables on our website. connector EasyConnect for solid cables without prog. device connector 90 with prog. device connector 90 connector EasyConnect for flexible cables without progr. device connector 90 with progr. device connector 90 Stripping tool for BA BB FA FB AA00 The connectors are also available in boxes containing 10 or 50 pieces. EasyConnect is a registered trademark of Systeme Helmholz GmbH. Programming device connector Order No BB50/-0FB50 yes Order No BA50/-0FA50 no Dimensions (LxWxH mm) 72 x 40 x 17 approx. 40g Outgoing cable vertical outgoing cable suitable for fast-connect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage consumption SUB-D connector, 9-way FC standard cable solid 0,64 mm V DC (must come from connected equip.) Current consumption max. 12,5 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % bei +25 C

3 34 Catalog 10 Bus Connector for, 90 Metalized housing No loosable parts Integrated terminating resistor 90 cable outlet Small housing Screw terminals Bus connector for with (l.) and without (r.) prog. device connector The compact design of the bus connectors from the Systeme Helmholz GmbH makes them suitable for use in all Siemens CPU types. A slide switch sets whether the connector will be used as a node or end of segment. The switch can also be operated when the connector is plugged. The switch setting is clearly visible. The connector must be used as a node ( OFF ) when the incoming bus (A1, B1) and the outgoing bus (A2, B2) are to be interconnected. This deactivates the terminating resistors. The connector must be set as a segment end ( ON ) on the first and last (extreme) stations of the segment. In that case the terminating resistors are connected on the incoming bus, the outgoing bus is disconnected. Bus connector for without prog. device connector 90 with prog. device connector 90 Stripping tool for BA BB AA00 The connectors are also available in boxes containing 10 or 50 pieces. Programming device connector Order No BB12 yes Order No BA12 no Dimensions (LxWxH mm) 64 x 40 x 17 approx. 40 g Outgoing cable vertical outgoing cable suitable for fastconnect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage consumption SUB-D connector, 9-way 4 terminals for wires up to 1.0 mm V DC (must come from connected equip.) Current consumption max. 12,5 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % bei +25 C

4 Catalog Bus Connectors for 90 with diagnostic LEDs 3 LEDs status displays Indicates bus operation, station transmitting, terminating resistor inserted Screw terminals Integrated terminating resistors No loosable parts Small housing Bus Connectors for with diagnostic LEDs The diagnostic connector can be used to connect a network in which the user can check the status of the bus system at any time at a glance. The three built-in LEDs with the easily distinguished colors blue, green and orange indicate the most important states of the network at each station. The state of the terminating resistor (orange), whether bus activity is in progress (green) and whether the station addressed is participating in bus traffic (blue) are all indicated. This means errors, such as bus interruptions, missing or incorrectly connected terminating resistors and malfunctioning or failed bus stations can be detected immediately. The diagnostic connector with screw terminals can be supplied with or without a programming (PG) device connector. Bus connector for with diagnostic LEDs without prog. device connector 90 with prog. device connector 90 Stripping tool for BA BB AA00 The connectors are also available in boxes containing 10 or 50 pieces. Programming device connector Order No BB12 yes Order No BA12 no Dimensions (LxWxH mm) 64 x 40 x 17 approx. 40 g Outgoing cable vertical outgoing cable suitable for fastconnect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage consumption SUB-D connector, 9-way 4 terminals for wires up to 1.0 mm V DC (must come from connected equip.) Current consumption max. 35 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % bei +25 C

5 36 Catalog 10 Bus Connectors for, 35 Metalized housing No loosable parts Integrated terminating resistor 35 cable outlet Small housing Screw terminals Bus connector 35 for The 35 bus connector for is a further component in our range of connectors providing you with low-cost, compatible alternatives for your automation. The bus connectors are used to connect a node to the cable. The connector is quickly mounted and features integrated terminating resistors. The Systeme Helmholz GmbH offers the bus connector with an 35 cable outlet and for transmission rates up to 12 Mbaud. Bus connector for 35 cable outlet, without prog. device connector BA41 35 cable outlet, with prog. device connector BB41 The connectors are also available in boxes containing 10 or 50 pieces. Programming device connector Order No BB41 yes Order No BA41 no Dimensions (LxWxH mm) 54 x 40 x 17 approx. 40 g Outgoing cable 35 axial outgoing cable, suitable for fast-connect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage consumption SUB-D connector, 9-way 4 terminals for wires up to 1.0 mm V DC (must come from connected equip.) Current consumption max. 12,5 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % bei +25 C

6 Catalog Bus Connectors for axial Metalized housing Integrated terminating resistor No loosable parts 180 cable outlet Screw terminals Busanschlussstecker axial für The axial bus connector for is a further component in our range of connectors providing you with low-cost, compatible alternatives for your automation. The bus connectors are used to connect a node to the cable. The connector is quickly mounted and features integrated terminating resistors. The Systeme Helmholz GmbH offers the bus connector with an axial cable outlet and for transmission rates up to 12 Mbaud. Bus connector for axial cable outlet CA12 The connectors are also available in boxes containing 10 or 50 pieces. Dimensions (LxWxH mm) 68 x 39,5 x 17 approx. 40 g Outgoing cable, axial axial outgoing cable, suitable for fastconnect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage consumption SUB-D connector, 9-way 4 terminals for wires up to 1.0 mm V DC (must come from connected equip.) Current consumption max. 12,5 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % bei +25 C

7 38 Catalog 10 Bus Connector for with Atex accreditation Metalized housing No loosable parts Integrated terminating resistor 90 cable outlet Atex-accreditation (EN : 1999) Screw terminals Bus connector for with Atex accreditation The bus connectors are used to connect a station to the cable. The connector is quickly mounted and has integrated, connectable terminating resistors. The Systeme Helmholz GmbH offers the busconnector for usage in explosion hazardous areas of zone 2 (explosive gasatmosphere appears seldom and for very short time). The bus connector is plugged directly onto the interface (SUB-D connector, 9-way) of the stations. The cables are connected using 4-way screw terminals. The cable can be prepared for connection using the fast-connect stripping tool from Siemens. Using a slide switch you can set whether the connector is to be used as a node or segment end. The switch can also be operated when the connector is installed. The setting can be clearly seen. Bus connector for without prog. device connector, Ex-Zone 2 with prog. device connector, Ex-Zone 2 Stripping tool for BA BB AA00 Programming device connector Order No BB12 yes Order No BA12 no Dimensions (LxWxH mm) 64 x 40 x 17 approx. 40 g Outgoing cable vertical outgoing cable suitable for fastconnect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage consumption SUB-D connector, 9-way 4 terminals for wires up to 1,0 mm V DC (must come from connected equip.) Current consumption max. 12,5 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % bei +25 C

8 Catalog Bus Connectors for with spring type terminals Metalized housing No loosable parts Integrated terminating resistor 90 cable outlet Spring type terminal Bus connector for with spring type terminals The bus connectors are used to connect a station to the cable. The connector is quickly mounted and has integrated, connectable terminating resistors. The spring type terminal is suiteable for solid conductors up to a cross section of 0.5 mm2. The stripped conductors contacts automatically when inserted, for breaking the connection the orange lever must be pressed. The bus connector is plugged directly onto the interface (SUB-D connector, 9-way) of the stations. The cables are connected using 4-way screw terminals. The cable can be prepared for connection using the fast-connect stripping tool from Siemens. Using a slide switch, you can set whether the connector is to be used as a node or segment end. The switch can also be operated when the connector is installed. The setting can be clearly seen. Bus connector for without prog. device connector, with spring connection technique with prog. device connector, with spring connection technique Stripping tool for BA BB AA00 Programming device connector Order No BA22 no Order No BB22 yes Dimensions (LxWxH mm) 65 x 48 x 16 approx. 40 g Outgoing cable vertical outgoing cable suitable for fastconnect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 MBit/s Interfaces station cable Voltage supply SUB-D connector, 9-way 4 terminals for wires up to 0.5 mm 2 DC V (must come from connected equip.) Current consumption max. 12,5 ma surrounding air temperature 0 C C transport and storage temperature -25 C C relative humidity max. 75 % at +25 C

9 40 Catalog 10 Compact Repeater a real alternative to conventional repeaters no additional space needed in the cabinet very flexible in its use can be used as a bus extension or spur line increases the number of nodes system expansion can also be used in MPI networks status LEDs 24 V supply is not necessary 5 V power supply direct from the, with that it s usable on every device Compact Repeater The new compact repeater from the Systeme Helmholz GmbH can be used flexibly due to its very compact size. The repeater enables transmission rates of 9.6 Kbps to 12 Mbps. The transmission signals are regenerated by the repeater and retransmitted. Transmission Rate max. segment length 9,6 kbit/s 1000 m 19,2 kbit/s 1000 m 45,45 kbit/s 1000 m 93,75 kbit/s 1000 m 187,5 kbit/s 1000 m 500 kbit/s 400 m 1500 kbit/s 200 m 3000 kbit/s 100 m 6000 kbit/s 100 m 000 kbit/s 100 m Dimensions (LxWxH mm) 64x 40 x 17 Power supply Voltage approx. 40 g + 5 V DC Current consumption typ. 100 ma Connection SUB-D, 9-way interface transmission rate max. 9,6 Kbit/s to 12 MBit/s autodetection Protocol DP per EN Compact Repeater RB12 Connection SUB-D, 9-way Stripping tool for Manual Compact Repeater, German/English AA RB12 Surrounding air temperature transport and storage temperature 0 C C -25 C C

10 Catalog Repeater for MPI and Transmission Rate max. segment length 9,6 kbit/s 1000 m 19,2 kbit/s 1000 m 45,45 kbit/s 1000 m 93,75 kbit/s 1000 m 187,5 kbit/s 1000 m 500 kbit/s 400 m 1500 kbit/s 200 m 3000 kbit/s 100 m 6000 kbit/s 100 m 000 kbit/s 100 m Repeater for MPI and The RS485 repeater connects two or MPI bus segments in RS485 technology with max. 32 nodes, including repeaters. With it, transmission rates of 9.6 Kbps to 12 Mbps are possible. The transmission signals are regenerated and retransmitted by the repeater. The repeater can therefore be used to implement long segments. Commissioning aids: Switch for disconnecting segments Display of bus activity Disconnection of a segment if terminating resistor has been wrongly connected Terminating resistor for every segment Error display on bus Switch for disconnecting repeater functions MPI-/-Repeater Manual MPI-/-Repeater German/English AA AA02 Dimensions (LxWxH mm) 115 x 110 x 35 approx. 240 g Power supply Voltage DC 24 V Current consumption max. 700 ma at 24 V Segment connection 2 terminal blocks Interface PG/OP interface Transmission rate max. 12 Mbit/s autodetection Protocol DP to EN Connection connection, SUB-D, 9-way surrounding air temperature transport and storage temperature 0 C C -25 C C

11 42 Catalog 10 Active Dropcable Programmable controller Slave Active Dropcable MPI/ PG/PC Dropcable for PG Application example Active Dropcable The active dropcable from the Systeme Helmholz GmbH is used for a failure-free connection of a programming device to an existing net. The active line is not a radial line because of it`s integrated electronic. Dropcable for PG, 3 m BD00

12 Catalog Terminal Block and Multiplexer for MPI and Terminal block for MPI/ in a metal housing Multiplexer for MPI-/ The MPI/ terminal block allows connection of up to two devices to an MPI or network. Two 9-way SUB-D connectors are located in the housing of the MPI/ terminal block. The segments can be disconnected by a switch. This action connects a terminating resistor combination. 5 V and 24 V is available at both connectors for supplying MPI and devices (e.g. SSW7 or operator terminals). The MPI/ multiplexer can be mounted directly onto a DIN rail. Programmable controller /MPI Multiplexer NETLink lite Operator Panel Programmable controller MPV MPV01 Dimensions (LxWxH mm) 115 x 110 x x 67 x 30 approx. 230 g approx. 135 g Power supply Voltage DC 24 V DC 24 V Current consumption max. 200 ma at 24 V 200 ma at 24 V interface Transmission max. 12 MBit/s 12 MBit/s Connection 2x female, SUB-D 9-way 4x 2 terminal 3x female, SUB-D, 9-way surrounding air temperature transport and storage temperature 0 C C -25 C C 0 C C -25 C C IP 20 PC Application example for MPI Multiplexer Power Plug The MPI/ multiplexer permits connection of up to 3 devices to one MPI or network. The MPI/ multiplexer has a 1.2 m long connecting cable that can be plugged directly into the MPI/ socket of the PLC but also at any position in an MPI or network. The PG socket is the only socket that has the full MPI pin assignment. That makes it possible to use direct operation on this socket via an MPI adapter ( SSW 7 or PC adapter ) with programming software. This pin assignment is not relevant for operation of devices. The MPI/ multiplexer is powered via the connection line to the CPU. If the terminal does not provide 24 V, it is possible to draw the 24 V from an external source. The 24 V connector for this purpose (green connector) is polarized. Terminal block for MPI/, in a metal housing Manual Terminal block for MPI/ in a metal housing, German/English Multiplexer for MPI/ in a plastic housing Manual Terminal block for MPI/ in a plastic housing, German/English Power Plug (optional) MPV MPV MPV MPV SNT01

13 44 Catalog 10 DP/DP Coupler up to 244 bytes of input data and 244 bytes of output data can be exchanged between two networks dual-redundant power supply electrical isolation between the networks addresses can be set by DIL switch or software Dimensions (LxWxH mm) 40 x 127 x 117 DP/DP Koppler Power Supply Nominal power supply Current consumption Electric isolation of the 24 V power supply to DP Mutually interface Transmission speeds Approx. 250 g 24 V DC (20.4 V V) approx. 150 ma at DC 24 V yes yes Mbaud The DP/DP coupler interlinks two DP networks and permits data transmission between the masters and the two DP networks. The maximum size of the transmitted data is 244 bytes of input data and 244 bytes of output data. The DP/DP coupler is configured in the S7 software or by means of a GSD file. Bus protocol DP Telegram length I/O data max. 244 bytes inputs/ 244 bytes outputs Surrounding air temperature 0 C C DP/DP Coupler Manual DP/DP Coupler, German/English AD AD01

14 Catalog NETL ink USB, Highspeed USB Gateway for MPI/ MPI/ up to 12 Mbps, autobaud USB 2.0 up to 480 Mbps 12 links on MPI/ Power supply via USB External 24 V power source possible With programming device connector (PG) as standard Support for all common Simatic 1) Engineering Tools USB NETL ink USB, Highspeed USB Gateway PC USB-interface USB-connecting cable (included) Programming and configuration via USB Visualization via USB NETL ink USB The NETL ink USB is an alternative to a -PCMCIA plug-in card. Its 1.2 m connecting cable is plugged directly into the CPU of the programmable controller. The connecting cable is an active cable and therefore does not influence the MPI/. The second programmer (PG) jack enables connection of a further device to the CPU of the programmable controller. The NETL ink USB permits conversion of a USB interface to MPI/ for programming or visualization with the full transmission rate of up to 12 Mbps. Furthermore 12 simultaneous links can be established. The new NETL ink USB is powered from the USB bus, but also features an optional 24 V DC power supply and automatic baudrate detection. At the USB end the protocols Fullspeed (12 Mbps) and Highspeed (480 Mbps) are supported. The MPI/ is electrically isolated from the external 24 V DC power source and from the USB interface (functional separation). A 3-m high-speed USB cable is included with the NETL ink USB. The firmware is always updateable to the newest volume with the included update-program SHTools. Programmable controller Application for NETL ink USB Dimensions (LxWxH mm) 102 x 54 x 30 approx. 180 g Power Supply Voltage DC 24 V ±25 % DC 5 V USB automatically selected Current consumption max. max. Communication interface Type USB ma at DC 24 V/ 500 ma at DC 5 V USB Connector Transmission rate MPI/ Type USB-B female connector 12 MBit (Fullspeed) /480 MBit (Highspeed) RS485, isolated NETL ink USB (incl. 3m USB cable) DIN rail adapter short Power Plug (optional) Manual NETL ink USB, German/English Order-No MPI HSH SNT MPI11 1) Simatic is a registered trademark of Siemens AG. NETL ink is a registered trademark of Systeme Helmholz GmbH. Transmission rate max. 12 MBit/s, autodetection Connector SUB-D, 9-way with PG interface and terminating resistor Protocols FDL frames Surrounding air temperature 0 C C Indicators 3 LEDs, therefrom 2 two coloured

15 46 Catalog 10 NETL ink PRO, Ethernet Gateway for MPI/ Support of all common Simatic Engineering Tools ISO on TCP (RFC 1006) for SCADA & OPC-Server Support of the PPI protocol for S7-200 applications Support of Slave Parameterization Security functions for protecting TCP/IP access Observe variables of S7 CPU in web browser Visualize web-services via HTML DHCP, Web configuration 12 connections on MPI/ 6 connections on TCP Power supply from the CPU or alternative via external 24 V supply possible With programming device connector (PG) as standard Repeater included in connector RJ45 jack for connecting the TCP cable Galvanic isolation NETL ink PRO, Ethernet Gateway Visualization via Ethernet Teleservice via Internet Programmable controller Visualization via dial-up router Protocol via Ethernet/PDA data acquisition Programming & configuring via Ethernet IP adress distribution viadhcp NETL ink PRO The NETLink PRO for programming, configuring and visualization of S7 PLCs from Siemens is plugged into the CPU of the programmable controller. The connecting cable is an active cable and therefore does not influence the MPI/. The bus connector is equipped with a programming unit socket to which additional devices can be connected. The NETLink PRO can optionally be powered from an external 24 V DC power source. At the controller end, the NETLink PRO via MPI and allows the full transmission speed of 12 Mbps and 12 simultaneous connections. Moreover, the new NETLink PRO features automatic baudrate detection and flexible configuration, such as DHCP and a Web interface. Protocol support for the RFC 1006 (ISO-on-TCP) permits the connection of a large number of visualization and SCADA systems, as well as OPC servers. The 3 m Ethernet connecting cable (straight) is provided with the NETLink PRO. At the TCP/IP-end the NETLink PRO can be used both in the LAN and in the WAN (for example via VPN). The MPI/ is electrically isolated from the external 24 V DC power source and from the Ethernet interface (functional separation). You can perform parameterization, diagnostics and update functions with the supplied SHTools software. DHCP Server PG/PC Application for NETL ink PRO in a LAN for example address distribution via DHCP Internet NETL ink PRO Programmable controller PG/PC Application for NETL ink PRO in a WAN for example via dial in router 1) Simatic is a registered trademark of Siemens AG

16 Catalog NETL ink PRO, Ethernet Gateway for MPI/ /MPI WAN SCADA NETL ink PRO S7 400 Internet S7 300 LAN STEP 7 XP/Vista Ethernet TCP/IP Operator Panel Router Application example for programming and projecting with different software tools in LAN and simultaneously connection with RFC 1006 via WAN MPI-/ Router (PAT) MPI-/ : : : :7777 Internet STEP 7 WinCC flexible Router Application example for the access to several NETL ink PRO via a public IP Address and by using Port and Address Translation Note To use the NETL ink PRO for teleservice via the analog or ISDN telephone network, we also offer the NETL ink Router. (see page 68) NETL ink PRO (incl. 3 m Ethernet cable) NETL ink PRO, 35 cable outlet for S7-400 Crossover-adapter DIN rail adapter short Power Plug (optional) Manual NETL ink PRO, German/English MPI MPI CROSS HSH SNT MPI11 NETL ink is a registered trademark of Systeme Helmholz GmbH. S7-200, S7-300, S7-400, STEP7 and WinCC are registerd trademarks of Siemens AG. Windows XP, Windows 2000 and Windows Vista are registered trademarks of Microsoft Corporation. Observe variables in the NETL ink PRO webserver. Dimensions (LxWxH mm) 102 x 54 x 30 approx. 180 g Power Supply Voltage DC 24 V ±25 % Current consumption max. 150 ma Communication interface Type Connector Transmission rate 10 Base-T 100 Base-TX RJ45 10/100 MBit/s autodetection MPI/ Type RS485, isolated Transmission rate max. 12 MBit/s, autodetection Connector SUB-D, 9-way with PG interface and repeater Protocols FDL frames, RFC 1006 surrounding air temperature 0 C C Indicators 3 LEDs, therefrom 2 two coloured

17 48 Catalog 10 NETL ink lite, Ethernet-Gateway for MPI/ MPI/ up to 12 MBit/s 4 links to MPI/ 2 links to TCP Power supply from PLC TCP/IP 10/100 MBit/s NETL ink lite PG/PC Programmable controller 2,5 m cable length Internet NETL ink lite, Ethernet-Gateway for MPI/ Application for the NETL ink lite in a WAN for example via dial in router Programming and configuration Teleservice NETL ink lite Programmable controller PG/PC Installed in a SUB-D shell it contains a complete field bus participant with a 10/100 Mbps Ethernet interface. It is connected directly to the field bus connector of an automation device and connects it to the next switch or hub via an Ethernet cable. The NETL ink lite can be used both in an MPI and in a network. The 24 volt power supply is drawn via the MPI/ connection. The driver supplied links the NETL ink lite into the programming software. All programming functions are available. The crossover adapter permits direct connection of the NETL ink lite to a laptop or PC without a hub or switch. We advise to use the NETL ink PRO for permanent installations for example visualizations and operating data record. 2,5 m cable length Crossover-Adapter Application for the NETL ink lite (with crossover adapter) for direct connection to your Network card Dimensions (LxWxH mm) 65 x 48 x 16 lite Power supply Voltage Current consumption Communication Interface: Ethernet Connection Type: Standard Connector Transmission rate approx. 140 g (incl. cable and connector) DC 24 V from PLC 50 ma 10 Base-T 100 Base-TX RJ45 10/100 MBaud autodetection NETL ink lite with S7-Switch Crossover-Adapter Manual NETL ink lite, German/English MPI CROSS MPI01 MPI Transmission rate max 12 MBit/s Data link FDL frames surrounding air temperature 0 C C Indicators 2 LEDs, one of them 2-coloured, communication status 1) NETL ink is a registered trademark of Systeme Helmholz GmbH.

18 Catalog 10????????????????????????????????????????????????????????????????? 49 OPC-Server Fast access to S7- and S5 data The S7/S5 OPC server allows you fast and easy access to process data in WinAC, S7-200, S7-300, S7-400, C7- and S5 controllers. Addressing of the variables can be performed completely in STEP7 semantics and can be imported directly from an Excel file or a STEP7 project if required. With each OPC-compliant client application, you can read or write all input/output data, data blocks, flags, timers and counters in the S7-/S5 controllers. You can also access up to 256 controllers at one time. The control program does not have to be adapted for communication with the S7/S5 OPC server. No detailed knowledge of the PLC program that is running is necessary. New functions and expansions On the S7-300 and S7-400 the DATE_AND_TIME and ASCII strings are supported as additional data formats. OPC Client Controls are now contained in the scope of supply of the S7/S5 OPC server as ActiveX components. The S5 syntax for creating items can now be used. Access to array elements has been improved. Integrated Web server The S7/S5 OPC server features an integrated Web server. This is used for diagnosing the OPC server and for providing its own Web pages for operating and monitoring using any standard browser. The architecture and performance of the Web server is designed for small visualization systems. Flexible connection There are many ways of connecting the controllers to the S7/S5 OPC server such as TCP/IP,, MPI, PPI or AS511. For communication, Systeme Helmholz GmbH provides the following devices: SSW7, SSW7-TS, SSW7-USB for MPI NETL ink PRO, NETL ink USB, NETL ink lite for MPI and SSW3, SSW4 and SSW5 for AS511 Also a selection of communication modules of other manufacturers, such as CP243, CP343, and CP443 from Siemens are supported. The current OPC server version and further technical information are available for download at Windows-OPC-Client via COM/DCOM XML-OPC-Client via HTTP Web-Browser via HTTP S7/S5-OPC-Server Direct reading of MPI PB TCP/IP PC/CP TCP/IP S7-project data by access to symbolic operands S7-300 S7-400 via MPI- Adapter S7-200 S7-300 S7-400 WinAC via -card S7-200 S7-300 S7-400 WinAC viatcp/ip S7-200 S7-300 S7-400 via Siemens CP 5511 CP 5512 CP 56 CP 5613 CP 5614 S5-115U bis 155U via TCP/IP ERP-connection Data entry Visualization S7/S5- OPC-Server SSW5 LAN NETL ink PRO NETL ink lite TCP-IP via Ethernet TCP-IP via Ethernet NETL ink USB SSW7 SSW7-TS SSW7-USB SSW 200 MPI-BUS Panel-PC S7-OPC-Server (Single licence) S7-OPC-Server with USB-Dongle OPC OPC20 NETL ink is a registered trademark of Systeme Helmholz GmbH. WinAC, S7-200, S7-300, S7-400, STEP7 and WinCC are registerd trademarks of Siemens AG. Windows is a registered trademark of Microsoft Corporation. Helsinki tel automation@klinkmann.fi St. Petersburg tel klinkmann@klinkmann.spb.ru Moscow tel moscow@klinkmann.spb.ru Yekaterinburg tel yekaterinburg@klinkmann.spb.ru Mineralnye Vody tel pyatigorsk@klinkmann.spb.ru Samara tel samara@klinkmann.spb.ru Кiev tel klinkmann@klinkmann.kiev.ua Riga tel klinkmann@klinkmann.lv Vilnius tel post@klinkmann.lt Tallinn tel klinkmann.est@klinkmann.ee Мinsk tel minsk@klinkmann.com

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

Bus Connector for PROFIBUS, 90

Bus Connector for PROFIBUS, 90 Catalog 09 PROFIBUS 31 Bus Connector for PROFIBUS, 90 Integrated terminating-resistor 90 cable-outlet Small housing with (l.) and without (r.) prog. device connector The compact design of the bus connectors

More information

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways NETL ink gateways Ethernet gateways WLAN gateways High-speed USB gateways ETHERNET NETL ink PRO PoE, PROFIBUS Ethernet gateway FEATURES RFC (ISO on TCP) CPU-to-CPU communication (with S-¹ and S-¹) (POE)

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

System Components for Automation. Catalog.

System Components for Automation. Catalog. System Components for Automation Catalog 15 www.helmholz.com 2 TB20 catalog 2 The TB20 distributed fieldbus I/O system is characterized by a variety of performance attributes for practical application.

More information

MPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter

MPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter MPI-BUS Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter 70 MPI-Bus Catalog 11 SSW7, MPI-Programming Adapter Features Programming and visualization up to 115 kbaud MPI up to 187,5 kbps Power

More information

PROFIBUS. Connectors Repeaters FO Wireless system Communication

PROFIBUS. Connectors Repeaters FO Wireless system Communication PROFIBUS Connectors Repeaters FO Wireless system Communication PROFIBUS CONNECTORS 8 PROFIBUS connector overview ORIENTATION PRODUCT IMAGE WITHOUT PG WITH PG PAGE 90 700-972-0BA12 700-972-0BB12 9 90 diagnosis

More information

10 Years. Gateways. System Components for Automation. Catalog.

10 Years. Gateways. System Components for Automation. Catalog. 10 Years Gateways System Components for Automation Catalog 14 www.helmholz.com 2 Have you seen our new TB20 catalog? The new TB20 distributed fieldbus I/O system by Systeme Helmholz was shaped by direct

More information

System Components for Automation Technology. Catalog.

System Components for Automation Technology. Catalog. System Components for Automation Technology Catalog 16 www.helmholz.com 2 TB20. Distributed Fieldbus I/O System In the TB20-3 catalog, you will find all information and ordering data in regard to our distributed

More information

System components for automation technology. Catalog.

System components for automation technology. Catalog. System components for automation technology Catalog 17 www.helmholz.com 2 TB20, DISTRIBUTED FIELDBUS I/O SYSTEM In the TB20-3 catalog, you will find all information and ordering data in regard to our decentralized

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

System Components for Automation 10

System Components for Automation 10 Catalog 10 Catalog 10 English Catalog System Components for Automation 10 www.helmholz.com www.helmholz.com www.helmholz.com Systeme Helmholz GmbH 91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135

More information

efive 100 Installation Guide

efive 100 Installation Guide ewon Installation Guide IG 013 / Rev 1.3 efive 100 Installation Guide Contents This short guide explains how to install the efive 100 Firewall and to get started with the embedded configuration web site.

More information

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2. SSW7-RK512/RS422 Adapter for MPI Bus with RK512 Protocol, RS422 700-752-5VK21 User Manual Version: 1 / 24.03.2009 HW: 1 / FW: 2.05 and later Order number of manual: 900-752-5VK21/en Systeme Helmholz GmbH

More information

Vision OPLC. Technical Specifications. V T34 Technical Specifications

Vision OPLC. Technical Specifications. V T34 Technical Specifications Vision OPLC V570-57-T34 Technical Specifications The Unitronics V570-57-T34 offers the following onboard I/Os via HE-10 connectors: 16 isolated Digital Inputs, configurable via wiring to include2 HSC/Shaft-encoder

More information

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en SSW7-USB 700-755-1VK21 User Manual Edition 3 / 10.10.2010 HW 6a and FW 3.29 and higher Order number of manual: 900-755-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 91091 Grossenseebach Phone: +49 9135

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Using your PC to access a remote M90 via GSM

Using your PC to access a remote M90 via GSM You can use a PC running U90 Ladder to access a remote M90 OPLC for programming and maintenance via GSM networks. To do this using the modems which are supplied with the M90 GSM Modem Kit: Connect your

More information

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21 SSW7 Adapter for MPI-Bus 700-751-1VK21 User Manual Version:2 / 2009-03-20 HW: 1 / FW: 3.0 and higher Order number of manual: 700-751-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach

More information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24 Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue

More information

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214PG (214-2BE03) Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:

More information

UniStream CPU-for-Panel

UniStream CPU-for-Panel UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic

More information

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet VIPA CPU 214NET PG (214-2BT13) Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active

More information

Structure and Function

Structure and Function Communication processors Communication processors Structure and Function Communication processors for the connection of different target and source systems, such as via Ethernet to higher-level MES and

More information

FiberINTER. FiberINTERF. FiberINTERFACES.

FiberINTER. FiberINTERF. FiberINTERFACES. FiberINTERF FiberINTERFACES FiberINTER The right solution for all network requirements at the field level: FiberINTERFACES from Hirschmann. Reaching your goal with fiber optic technology even under extreme

More information

SNAP PAC Redundancy Option Kit

SNAP PAC Redundancy Option Kit SNAP PAC Redundancy Option Kit Features Standalone arbiter monitors and controls the active and backup status of redundant controllers Redundancy power switch controlled by the arbiter enables remote rebooting

More information

UniStream HMI Panel. CPU-for-Panel

UniStream HMI Panel. CPU-for-Panel UniStream HMI Panel Installation Guide USP-070-B10,USP-104-B10, USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW Version 2 en ab FW 1.02 Quick Start Guide PN/CAN Gateway Layer 2 www.helmholz.de Content 1. Introduction 3 2. Preparation of the PN/CAN Gateway 3 3. Configure PN/CAN Gateway 4 4. PN/CAN Gateway settings

More information

CP BACNET Function

CP BACNET Function CP 343-1 BACNET Function The CP 343-1 BACnet independently handles data traffic via Industrial Ethernet and BACnet protocol. The module has its own processor and can be put into service directly using

More information

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0 CP 340 Overview The economical complete solution for serial communication via point-to-point links. 3 versions with different transmission interfaces: - RS 232C (V.24) - 20 ma (TTY) - RS 422/RS 48 (X.27)

More information

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522 4.2 ISDN devices 502 506 512 522 532 536 542 552 556 Voltage VDC 24 Current ma (24V) 60 60 70 90 90 100 80 100 110 Protection class (IP) 20 Range of use Dry Surroundings Temperatures (Plant) 0 50 C Temperatures

More information

PA ROUTERS. The following criteria can be applied when choosing the network transition:

PA ROUTERS. The following criteria can be applied when choosing the network transition: PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied

More information

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120. Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise

More information

TIM 3V- IE ADVANCED. Function

TIM 3V- IE ADVANCED. Function TIM 3V- IE ADVANCED Function The TIM 3V-IE Advanced enables one or more SIMATIC S7-300 or control center PCs (e.g. SINAUT ST7cc or ST7sc) to exchange data with other SINAUT ST7 or ST1 stations via any

More information

Supplementary Components Network transitions

Supplementary Components Network transitions Siemens AG 201 Overview Benefits PROFINET applications Protection of investment due to simple connection of PROFI- BUS DP slaves to PROFINET IO controller Also enables use in plants with PROFIsafe applications

More information

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory. Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING

More information

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-RO8 and IO-DI8-RO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Vision OPLC V350-35-B1/V350-J-B1 Installation Guide The Unitronics V350-35-B1/V350-J-B1 offers the following features: I/O configurations can be added via Expansion Modules. General Description V350 OPLCs

More information

modunet292: novanet-ethernet interface

modunet292: novanet-ethernet interface SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation

More information

Component identification

Component identification IO-ATC8 I/O Expansion Module 8 Analog/Thermocouple Inputs The IO-ATC8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 inputs that

More information

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE Automation innovative and secure networking

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE Automation innovative and secure networking REPEATERS SWITCHES INDUSTRIAL REMOTE SOLUTIONS FIELDBUS CONNECTIONS INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE Automation innovative and secure networking www.helmholz.de GATEWAYS FIREWALL INDUSTRIAL

More information

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs JZ10-11-PT15 3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs Jazz Micro-OPLCTechnical Specifications Power supply Input voltage Permissible range 20.4VDC to 28.8VDC with

More information

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS TELESERVICE Teleservice with TS Adapter IE Teleservice with TS Adapter II Page 1864 Mar 2008 Siemens ITS For performing remote maintenance over the telephone network: A PG/PC with an Engineering Tool installed,

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 1 MB WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU 315-2 PN/DP, CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

More information

IE/PB LINK PN IO. PROFINET applications

IE/PB LINK PN IO. PROFINET applications IE/PB LINK PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence

More information

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application www.helmholz.de MAC: ----- FCN RST Ext. V DC 8... V + FE IN IN PWR RUN BF SF Helmholz TB-C PROFINET IO Helmholz TB-C PROFINET IO

More information

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU315F-2 PN/DP, CENTRAL PROCESSING UNIT WITH 512 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

More information

Brief instruction. Version. 3en.

Brief instruction. Version. 3en. Brief instruction Version 3en www.helmholz.com Application and functional description The FLEXtra FO is primarily a normal PROFIBUS repeater with the capability of expansion by 2 (with FO-2) or 5 (with

More information

Industrial Ethernet from Hirschmann. WELCOME TO ATEX ZONE 1: SIMPLY A GOOD CONNECTION

Industrial Ethernet from Hirschmann. WELCOME TO ATEX ZONE 1: SIMPLY A GOOD CONNECTION WELCOME TO ATEX ZONE 1: Industrial Ethernet from Hirschmann. Modular system consisting of a MICE switch with microfx media module and an op-is microfx transceiver MICE switch for installation in Ex zone

More information

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models V230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU319F-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT

More information

Product type designation. General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current Data sheet SIMATIC S7-300, CPU 312C COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

BMS-Ethernet-Gateway COM460IP

BMS-Ethernet-Gateway COM460IP BMS-Ethernet-Gateway TDB501015en / 11.2012 BMS-Ethernet-Gateway BMS-Ethernet-Gateway Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between BMS bus and Ethernet Range of

More information

General information. Supply voltage

General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS CPU 319F-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 error and interrupt events are stored in a buffer

More information

LIMANDA Handheld Enclosures Product Drawings Last Updated 6/5/2008

LIMANDA Handheld Enclosures Product Drawings Last Updated 6/5/2008 ROSE+BOPLA ENCLOSURES A PHOENIX MECANO COMPANY LIMANDA Handheld Enclosures Product Drawings Last Updated 6/5/2008 Dimensional Drawings Limanda Handheld Designed for electronic data acquisition and operating

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC Installation Guide, V350/V130 COM Modules V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a Vision350 or Vision130 controller.

More information

Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections

Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections Simplify Your Wiring and Reduce Errors Let s face it: in

More information

Data sheet CPU 015PN (015-CEFPR01)

Data sheet CPU 015PN (015-CEFPR01) Data sheet CPU 015PN (015-CEFPR01) Technical data Order no. Module ID - General information Note - Features Technical data power supply 015-CEFPR01 CPU 015PN Powered by SPEED7 Work memory [KB]: 256...512

More information

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs Vision OPLC V350-35-T38 Technical Specifications The Unitronics V350-35-T38 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 2 HSC/Shaft-encoder Inputs

More information

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW Quick Start Guide PN/CAN-Gateway Version 1 en from FW 1.00 www.helmholz.com Content 1. Introduction 3 2. Preparation of the PN/CAN-Gateway 3 3. Plan PN/CAN-Gateway 4 4. Configure PN/CAN-Gateway 5 5. Add

More information

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7: CPU 315-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

System Components for Automation. Catalog.

System Components for Automation. Catalog. System Components for Automation Catalog 12 www.helmholz.com 2 Catalog 12 How to contact us: Orders by phone: +49 9135 7380-0 Orders by fax: +49 9135 7380-490 Orders by email: orders@helmholz.de In the

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

Data sheet VIPA CPU M13C (M13-CCF0000)

Data sheet VIPA CPU M13C (M13-CCF0000) Data sheet VIPA CPU M13C (M13-CCF0000) Technical data Order no. M13-CCF0000 Type VIPA CPU M13C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power

More information

CARLO GAVAZZI. Automation Components. The quick-fit energy metering solutions

CARLO GAVAZZI. Automation Components. The quick-fit energy metering solutions CARLO GAVAZZI Automation Components The quick-fit energy metering solutions EM200 quick-fit The quick-fit energy metering solutions Nowadays energy cost control is very important, so a detailed energy

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

CP ADVANCED. Function

CP ADVANCED. Function CP 343-1 ADVANCED Function The CP 343-1 Advanced independently handles data traffic over Industrial Ethernet. The module has its own processor and can be put into service directly using the unique preset

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB Automation Technology > Automation Systems > Industrial Automation Systems SIMATIC > Distributed I/Os SIMATIC ET200 > ET 200 systems for the cabinet > ET 200S > Interface modules > Interface modules with

More information

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory Data sheet SIMATIC S7-400H, CPU 414-5H, CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 5 INTERFACES: 1X MPI/DP, 1X DP, 1X PN AND 2 FOR SYNC MODULES 4 MB MEMORY (2 MB DATA/2 MB CODE) Product type designation

More information

COMTRAXX COM460IP. BMS-Ethernet-Gateway

COMTRAXX COM460IP. BMS-Ethernet-Gateway COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP_D00023_03_D_XXEN/11.2015 COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between

More information

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage. Input current. Power loss Data sheet SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 256 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE MICRO MEMORY CARD NECESSARY Product type designation

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300, CPU 315F-2DP FAILSAFE CPU WITH MPI INTERFACE INTEGRATED 24V DC POWER SUPPLY, 384 KB WORKING MEMORY, 40MM WIDE, 2. INTERFACE DP- MASTER/SLAVE MICRO MEMORY CARD REQUIRED General

More information

Revision History. Version Date Changes Description of bridge mode settings via web interface Initial version

Revision History. Version Date Changes Description of bridge mode settings via web interface Initial version MANUAL ANAGATE CAN ANALYTICA GmbH Vorholzstrasse 36 Tel. +49 721 35043-0 E-mail: info@analytica-gmbh.de D-76137 Karlsruhe Fax: +49 721 35043-20 WWW: http://www.analytica-gmbh.de 1 2004-2006, Analytica

More information

IO-DI16, IO-DI16-L I/O Expansion Modules

IO-DI16, IO-DI16-L I/O Expansion Modules IO-DI16, IO-DI16-L I/O Expansion Modules 16 Digital Inputs The IO-DI16 and IO-DI16-L are I/O expansion modules that can be used in conjunction with specific Unitronics OLC controllers. The modules are

More information

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Screen 2.4 3.5 Color Touch 4.3 Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed V130-33-TR20/V130-J-TR20 V350-35-TR20/V350-J-TR20 V430-J-RH2 Installation Guide 12 Digital Inputs, including 2 Analog, 3 HSC/Shaft-encoder inputs 6 Relay Outputs 2 high-speed npn Transistor Outputs (TR20

More information

V E62B Snap-in I/O Module

V E62B Snap-in I/O Module V200-18-E62B Snap-in I/O Module The V200-18-E62B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 30 isolated digital

More information

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

Vision OPLC. V TR6 Technical Specifications. Technical Specifications. V350-35-TR6 Technical Specifications The Unitronics V350-35-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage) and 1 HSC/Shaft-encoder

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Vision OPLC V TR20/V350-J-TR20

Vision OPLC V TR20/V350-J-TR20 Vision OPLC V350-35-TR20/V350-J-TR20 Installation Guide The Unitronics V350-35-TR20/V350-J-TR20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, and 3

More information

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times Data sheet SIMATIC S7-400H, CPU 417H CENTRAL UNIT FOR S7-400H 4 INTERFACES: 1 MPI/DP, 1 DP A. 2 FOR SYNC MODULES 4MB MEMORY (2MB CODE/2MB DATA) Supply voltage Rated value (DC) 24 V DC Input current from

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Data sheet CPU 015PN (015-CEFPR00)

Data sheet CPU 015PN (015-CEFPR00) Data sheet CPU 015PN (015-CEFPR00) Technical data Order no. 015-CEFPR00 CPU 015PN Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply (permitted

More information

CARLO GAVAZZI Automation Components. Switching Power Supplies from 5W up to 960W

CARLO GAVAZZI Automation Components. Switching Power Supplies from 5W up to 960W CRLO GVZZI utomation Components Switching Power Supplies from 5W up to 960W SPD, SPM, SPPC Switching power supplies Carlo Gavazzi provides one of the most complete ranges of power supplies for the automation

More information

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. Vision OPLC V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. General Description V1210 OPLCs are programmable logic controllers that comprise a built-in operating

More information

Product type designation. General information. Supply voltage. Input current. Power losses

Product type designation. General information. Supply voltage. Input current. Power losses Data sheet SIMATIC S7-300, CPU317-2 DP, CENTRAL PROCESSING UNIT WITH 1 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, MICRO MEMORY CARD NECESSARY Product type designation

More information

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS CPU 317F-2 DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 errors and interrupt events are saved in a buffer for

More information

Product and Applications Description

Product and Applications Description IP N146/02 Product and Applications Description The IP N146/02 is a DIN rail mounted device. The device implements the KNXnet/IP standard and connects KNX/EIB lines via data networks using the Internet

More information

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory Data sheet SIMATIC S7-400, CPU 412-2 CENTRAL PROCESSING UNIT WITH: 512 KB WORKING MEMORY, (256 KB CODE, 256 KB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP Product type designation General

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

Vision OPLC V TR20

Vision OPLC V TR20 Vision OPLC V130-33-TR20 Installation Guide The Unitronics V130-33-TR20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, and 3 HSC/Shaft-encoder Inputs

More information

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory Data sheet SIMATIC S7-400, CPU 417-4 CENTRAL PROCESSING UNIT WITH: 30 MB WORKING MEMORY, (15 MB CODE; 15 MB DATA) 1. INTERFACE MPI 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3./4. IF IFM MODULES PLUGGABLE Product

More information

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models V230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information