EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
|
|
- Joan Richard
- 6 years ago
- Views:
Transcription
1 Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage V DC Current Consumption Gateway (Ub = 24 V) < 100 ma Temperature Range C Short Circuit Protection Reverse Polarity Protection Overload Protection Interface RS-232 Baud Rate RS-232 < Bd Baud Rate PROFINET < 100 MBd Number of Bus Clients 512 Protection Class III Mechanical Data Material Plastic PA Weight 150 g Degree of Protection IP20 Connection Mode Supply Voltage Connection RS-Side Connection Bus Side RJ45 DIN-Rail mounting 35 mm PROFINET Connection Table No. 42 Suitable Connection Technology No. 74 These fieldbus gateways allow an easy connection of sensors and scanners to PROFINET. Industrial Communication
2 All dimensions in mm (1 mm = Inch) Specifications are subject to change without notice
3 Fieldbus Gateway RS-232 to EtherNet/IP ZAG45EN01 Part Number Easy handling Gateway from RS-232/422/485 interfaces to EtherNet/IP Technical Data Electrical Data Supply Voltage V DC Current Consumption Gateway (Ub = 24 V) < 100 ma Temperature Range C Short Circuit Protection Reverse Polarity Protection Interface RS-232 Baud Rate RS-232 < Bd Baud Rate EtherNet/IP < 100 MBd Number of Bus Clients 512 Protection Class III Mechanical Data Material Plastic PA Weight 140 g Degree of Protection IP20 Connection Mode Supply Voltage Connection RS-Side Connection Bus Side RJ45 DIN-Rail mounting 35 mm EtherNet/IP Connection Table No. 41 Suitable Connection Technology No. 74 These fieldbus gateways allow an easy connection of sensors and scanners to EtherNet/IP. Industrial Communication
4 All dimensions in mm (1 mm = Inch) Specifications are subject to change without notice
5 Fieldbus Gateway RS-232 to Fast Ethernet ZAG45FN01 Part Number Easy handling Gateway from RS-232/422/485 interfaces to Fast Ethernet Technical Data Electrical Data Supply Voltage V DC Current Consumption Gateway (Ub = 24 V) < 100 ma Temperature Range C Short Circuit Protection Reverse Polarity Protection Interface RS-232 Baud Rate RS-232 < Bd Baud Rate Ethernet < 100 MBd Number of Bus Clients 512 Protection Class III Mechanical Data Material Plastic PA Weight 140 g Degree of Protection IP20 Connection Mode Supply Voltage Connection RS-Side Connection Bus Side RJ45 DIN-Rail mounting 35 mm Fast Ethernet Connection Table No. 43 Suitable Connection Technology No. 74 These fieldbus gateways allow an easy connection of sensors and scanners to Fast Ethernet. Industrial Communication
6 All dimensions in mm (1 mm = Inch) Specifications are subject to change without notice
7 Fieldbus Gateway RS-232 to PROFIBUS DP ZAG73AN01 Part Number Easy handling Gateway from RS-232 interfaces on Profibus DP Voltage supply of external units (24 V DC or 5 V DC) via the gateway Technical Data Electrical Data Supply Voltage V DC Voltage Supply of external products 5 V Voltage Supply of external products 24 V DC Current Consumption Gateway (Ub = 24 V) < 100 ma Current Consumption Sensor (Ub = 5 V) < 500 ma Current Consumption Sensor (Ub = 24 V) < 400 ma Temperature Range C Short Circuit Protection Reverse Polarity Protection Interface RS-232 Baud Rate PROFIBUS < 12 MBd Baud Rate RS-232 < Bd Number of Bus Clients 126 Protection Class III Mechanical Data Housing Material Plastic PA Weight 130 g Degree of Protection IP20 Connection Mode Supply Voltage, I/O Connection Mode Supply Voltage Connection RS-Side Connection Bus Side SubD 9 B DIN-Rail mounting 35 mm PROFIBUS DP Connection Table No. 38 These fieldbus gateways allow an easy connection of sensors and scanners to PROFIBUS DP. Industrial Communication
8 All dimensions in mm (1 mm = Inch) Specifications are subject to change without notice
9 Fieldbus Gateway RS-232 to PROFIBUS DP ZAG73AN02 Part Number Technical Data Electrical Data Supply Voltage V DC Voltage Supply of external products 5 V Current Consumption Sensor (Ub = 5 V) < 1 A Temperature Range C Short Circuit Protection Reverse Polarity Protection Interface RS-232 Baud Rate PROFIBUS < 12 MBd Baud Rate RS-232 < Bd Number of Bus Clients 126 Protection Class III Mechanical Data Housing Material Plastic Degree of Protection IP65 Connection Mode Scanner SubD 9 S Connection Mode Supply Voltage M12 1; 4-pin Connection Bus Side M12 1; 4-pin PROFIBUS DP Connection Diagram No. 708 Suitable Connection Technology No. 2 Gateway from RS-232 interfaces on Profibus DP Protection mode IP65 Voltage supply of external units (5 V DC) via the gateway These fieldbus gateways allow an easy connection of sensors and scanners to PROFIBUS DP. Industrial Communication
10 All dimensions in mm (1 mm = Inch) nc nc Legend Supply Voltage + Supply Voltage 0 V Supply Voltage (AC Voltage) Switching Output (NO) Switching Output (NC) Contamination/Error Output (NO) Contamination/Error Output (NC) Input (analog or digital) Teach Input Time Delay (activation) Shielding Interface Receive Path Interface Send Path Ready Ground Clock Output/Input programmable Power over Ethernet Safety Input Safety Output Signal Output not connected Test Input Test Input inverted Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output + Valve Control Output 0 V Synchronization Receiver-Line Emitter-Line Grounding Switching Distance Reduction Ethernet Receive Path Ethernet Send Path Interfaces-Bus A(+)/B( ) Emitted Light disengageable Magnet activation Input confirmation Contactor Monitoring Wire Colors according to DIN IEC 757 Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Complementary Products Interface Cable FISZ-RS23207 Interface Cable S232W3 Specifications are subject to change without notice
IB080QM65VA3 Part Number
Inductive Proximity Switch with increased Switching Distance IB080QM65VA3 Part Number Technical Data Inductive Data Switching Distance 8 mm Correction Factors V2A/CuZn/Al 0,93/0,40/0,36 quasi-flush A/B/C/D
More informationYM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number
Contrast Sensor YM24PAH2ABF Part Number High switching frequency Small light spot Time delay can be activated LASER Technical Data Optical Data Range 150 mm Adjustable Range 60...150 mm Switching Hysteresis
More informationOFP401P0189. Color Sensor. Operating Instructions
OFP401P0189 Color Sensor Operating Instructions Last update: 23 May 2013 2 Table of contents 1. Proper Use 4 2. Safety Precautions 4 3. EC Declaration of Conformity 4 4. Technical Data 5 4.1. Connection
More informationOPT2011. High-performance distance sensor. Operating Instructions
OPT2011 High-performance distance sensor Operating Instructions Status: 15/07/2013 2 Table of Contents 1. Use for Intended Purpose 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning
More informationOPT2015. High-performance distance sensor. Operating Instructions
OPT2015 High-performance distance sensor Operating Instructions 23.07.2013 2 Index 1. Proper Use 4 2. Safety Precautions 4 2.1. Safety Precautions 4 2.2. Laser/LED warning 4 3. EC Declaration of Conformity
More informationValve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)
Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface
More informationInclination sensors 1-dimensional, measuring range
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More informationXUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN
Characteristics photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN Complementary Enclosure material Lens material Maximum sensing distance Output type Add on input Wire insulation material Status
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationInstallation instructions Inclination sensor EC2019 EC / / 2013
Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics
More informationcamera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition
ipf opti-check 1070 53 x 99.5 x 38mm camera sensor operating distance variable C-mount for lenses integrated flash controller short set-up times because of up to 255 check programs with up to 32 feature
More informationInclination sensors 2-dimensional, measuring range up to ±90
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More informationInclinometer. 4-20mA and RS232
Inclinometer 4-20mA and RS232 Real size Main Features - Two axis digital inclinometer n - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Active linearization and temperaturecompensation
More informationFieldbus Gateway Type ME43
Fieldbus Gateway Type ME43 Gateway for Industrial Ethernet and Fieldbus standards Up to 128 input and 128 output variables can be assigned Easy integration in the process control system ensured through
More informationFieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm
Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected
More informationSystem Control Unit (SCU)
ystem Control Unit (CU) Fieldbus coupler for Industrial Ethernet and Fieldbus standards Up to 28 input and 28 output variables can be assigned Easy integration in the process control system ensured through
More information0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials
Options, cables and accessories scancontrol 2x0/29x0 Options*: /SI Integrated sensor ON/OFF /PT Pigtail cable Hardware ON/OFF of the laser line 0.2m long cable directly out of the sensor /3B Class 3B /BL
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk
More informationDevice manual AS-i PowerSwitch ZB0028 ZB0040
Device manual AS-i PowerSwitch ZB0028 ZB0040 System AS-i Page 1 of 16 Device manual POWERSWITCH ZB0028 ZB0040 Date: 04/02/02 Contents 1. Views... 3 1.1 Top view... 3 1.2 Front view... 4 1.3 Bottom view...
More informationContacts for your success:
Contacts for your success: Austria - Linz wenglor sensoric gmbh +43 (0)732 7597-77 info.at@wenglor.com Belgium - Brussels wenglor sensoric +32 2 412 47-90 info.be@wenglor.com Brazil - Sao Paulo Steletronic
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationOPT2022. Color Sensor. Operating Instructions. Available as PDF only Status: Version:
EN OPT2022 Color Sensor Operating Instructions Available as PDF only Status: 06.07.2017 Version: 1.0.0 www.wenglor.com Table of Contents 1. General...4 1.1. Information Concerning these Instructions...4
More informationSafety controller unit B1 /
Version 1.0 Safety controller unit 470111B1 / For 2 to 16 safety sensors 470115B1 PL d in acc. with EN ISO 13849-1 / SIL CL 2 in acc. with EN IEC 62061 Two safety outputs and external contactor monitoring
More informationicex-cmtm General specs and Installation guide
icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationAbsolute encoders - SSI
Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available
More informationAbsolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485
Optical multiturn encoders 1 bit ST / 12 bit MT, RS485 Features Encoder multiturn / RS485 Optical sensing method Resolution: singleturn 1 bit, multiturn 12 bit Clamping or synchro flange Fieldbus protocol
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationData Sheet for Joysticks
Different handle designs available Optionally with Pushbuttons and Deadman Industrial-suited robust design IP classes up to 68 (on request) Several Output Options (analog, CAN J1939, CANopen, USB) The
More informationDPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2
Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering
More informationWTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet
WTX120 Legal-for-trade industrial weighing terminal Special features - Connection of up to 8 SG load cells (350 ohm) via plug terminals - Display resolution up to 30,000, legal for trade up to 10,000e
More informationInterface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands
Valve Islands > 016 > Series CX multi-serial module Series CX multi-serial module New Interface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands»»
More informationHigh Performance Distance Sensors
High Performance Distance Sensors This group brings together the most powerful sensors for distance measurement, which work in reflex mode according to different principles. High performance distance sensors
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution
GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional
More informationDistance and Position Sensors
Distance and Position Sensors SENSORS FOR DISTANCE AND POSITION Using various measuring techniques, HYDAC offers different distance and position sensors for a wide array of mobile and stationary applications.
More informationData Sheet MEM 22. Absolute Encoder Multiturn
Absolute Encoder Multiturn Features Resolution: Singleturn: up to 16,384 (14 Bit) steps per revolution Multiturn: up to 16,777,216 (24 Bit) revolutions Interface: SSI (synchron serial interface) or BiSS
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationSturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold
L-LAS Series L-LAS-LT-85-RA-CL (Reduced Amplification) - Operates in an angle of total reflection - Suitable für high-glossy objects (e.g. glass) - Line laser
More informationPhone: Fax: Web: -
In automated systems, sensors and actuators must interact with one another functionally and safely. The necessary coordination is performed by the programmable Safety Controller. The controller monitors
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationData Sheet for Joysticks
Different handle designs available Optionally with Pushbuttons and Deadman Industrial-suited robust design IP classes up to 8 (on request) Several Output Options (analog, CAN, USB) The TRY80 series provides
More informationF3EM Measuring lightcurtain in robust aluminium housing
Measuring lightcurtain in robust aluminium housing F3EM Measuring lightcurtain in robust aluminium housing The F3EM provides easy to install and set up height and profile measurement. The analog output
More informationNEW. Servo Controller Series E1100 E1100-DP E1100-MP E1100-DN E1100-RS E1100-MT E1100-CO E1100-GP
NEW Servo Controller Series E1100 E1100-DP E1100-MP E1100-DN E1100-RS E1100-MT E1100-CO E1100-GP Servo Controller Series E1100 The LinMot controller series E1100 are full digital controlled servo amplifiers
More informationAS-Interface Safety at Work
AS-Interface Safety at Work Safety Monitor, Coupling adjacent AS-i networks with the Safety Monitor provides the option of a cross-network E-Stop connection and a global restart, especially with large
More informationOriginal operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016
Original operating instructions Safety relay with relay outputs with and without delay UK G50S 803638 / 00 0 / 06 Contents Preliminary note...4. Symbols used...4 Safety instructions...5 3 Items supplied...6
More informationOriginal operating instructions Safety relay with relay outputs G1501S / / 2016
Original operating instructions Safety relay with relay outputs G50S UK 8023637 / 00 02 / 206 Contents Preliminary note...4. Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions
More informationAbsolute Encoder Multiturn
Absolute Encoder Multiturn Features Resolution: Singleturn: up to 16,384 (14 Bit) steps per revolution Multiturn: up to 16,777,216 (24 Bit) revolutions Interface: SSI (synchron serial interface) or BiSS
More informationMounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth
L-LAS Series L-LAS-TB-50-CL - Line laser
More informationControl block CPX-CM-HPP
Key features New options for controlling drive technology The control block CPX-CM-HPP makes all of Festo s electric drive technology compatible with all industrial communication interfaces. CPX-CM-HPP
More informationInstallation instructions Diagnostic electronics for vibration sensors VSE / / 2007
Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical
More informationData sheet CPU 115 (115-6BL02)
Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,
More informationEC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method
Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available
More informationTemp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
More informationNote: the wiring of the dead-man buttons has been changed since October 2001.
UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making
More informationB&R X67_IO_System_V3.14_E. X67 - System
B&R X67_IO_System_V3.14_E X67 - System X67 I/O System - Benefits to the User Why I/Os in the IP67? Potential of the remote machine concept Cost reduction with remote I/O concept Reduced wiring Minimization
More informationwith Backlight Graphic LCD Screen
with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of
More information4/20: Analog output mA (instead of V) Sturdy aluminium housing, anodized in blue. 7-pole fem. connector.
A-LAS Series A-LAS-CON1 A-LAS-CON1-4/20 - Electronic control unit for control of max. two A-LAS sensors - 100%-check of objects (tolerance band check) - Object positioning and thickness control (in μm
More informationXXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12
Characteristics Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Complementary Enclosure material Front material Supply voltage limits Function available [Sa] assured operating
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More information(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!
L-LAS Series L-LAS-LT-1000-HS (High Speed) - Line laser
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationBVS UR E Ordering code: BVS001H
BVS UR-3-101-E Ordering code: BVS001H Vision sensor BVS-E Universal PNP (2x) 1) Teach reference image, 2) Power, 3) Output 1 active, 4) Output 2 active, 5) Connection with PC, 6) Sharpness Characteristic
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationProximity sensors SME-8M, for T-slot Technical data Magnetic reed
Function e.g., 3-wire, with cable e.g., 3-wire, with plug Magnetic reed measuring principle Insertable in the slot from above, does not protrude over the cylinder profile Cable clip and inscription labels
More informationSafety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO
Safety control unit for 2 to 16 machine safety sensors 470 121 B1 / 470 125 B1 + PLd according to EN ISO 13849-1 + two safety outputs and external contactor monitoring + for sensors with N.O./N.C. system
More informationManual Fiber Optic Interfaces
Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it
More informationL-LAS Series. L-LAS-TB-F-6x1-40/40-CL L-LAS-TB-F-1x6-40/40-CL. Design. L-LAS Series Laser Line Sensors. Product name:
L-LAS Series L-LAS-TB-F-6x1-40/40-CL L-LAS-TB-F-1x6-40/40-CL - Line laser
More informationNote: KLASCHKA КB WIDENT/P 1/9
3.2 for 8 positions (NC contact) Position detector for detection of eight different codes with eight outputs (NC contact). 3.3 for 15 positions (Binary code) Position detector for detection of 15 different
More informationL-LAS Series. L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40. Design. L-LAS Series Laser Line Sensors. Product name:
L-LAS Series L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40 - Laser line sensor, 1 mw, class 2 laser product - Visible laser line (red light 670 nm), typ. 9.5 mm x 1.5 mm - Measuring range typ. 8 mm - Resolution
More informationColor Mark Photoelectric Sensor E3S-VS
Sensing Supply voltage Output 12 to 80 ma, with 1.5 to 4 ma constant current source; 1.2 cm, 5 cm 100 ma, Color Mark Photoelectric Sensor Small Color Mark Sensor With Built-In DC Amplifier Fast, 1 ms maximum
More information1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz
Description Operation mode and max sensing range: Diffuse proximity: 0-5 m Background suppression: 0- m Compact rectangular housing (x mm) Cable or rotatable plug connection via potentiometer Switch selectable
More informationPC Vision Wiring Guide
PC Vision Wiring Guide TTL TTL OPTO OPTO +V S T S T S+ S- T+ T- S+ S- T+ B- +V POWER OUTPUT +V POWER OUTPUT STRB/TRIG STRB/TRIG STROBE TRIGGER O STROBE TRIGGER A/B A/B A/B A/B +V A B A B A+ A- B+ B- A+
More informationTHYRO-S THYRO-A THYRO-AX THYRO-PX
THYRO-FAMILY = ACCESSORIES THYRO-S THYRO-A THYRO-AX THYRO-PX 2018 Advanced Energy Industries, Inc. Enhance Your Thyro-Family THYRO-FAMILY SCR POWER CONTROLLERS Thyro-Family Accessories No other SCR power
More informationØ 58 mm, depth 48 mm Shaft dimension. Hollow Ø 15 mm, solid Ø 6 or 10 mm Shaft loading (axial and radial)
ABSOLUTE ENCODERS AMT58 SSI Multi-turn Line Standard dimension Ø58mm Hollow or solid shaft Very high resolution Very high accuracy APPLICATIONS -Motion control -Automated machinery -Length measurement
More informationNOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI
NOVOTURN Multiturn-Sensor non-contacting Series RSM2800 digital SSI, SPI Special features True Power On System: counts turns even when not powered. Patented non-volatile technology does not require gears
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental
NOVOHALL Rotary Sensor non-contacting Series RSC2800 digital SSI, SPI, Incremental The contactless sensor utilizes the orientation of a magnetic field for the determination of the measurement angle. The
More informationPOSICHRON PCQA Mounting Sets
PCQA Mounting Sets Mounting set PCQA-BFS1 with mounting clamps Isolation sleeve 46 Isolation strip Mounting clamp P 58 Option -BFW Mounting brackets for PCQA22 and PCQA24 Note: The option -BFW can only
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationPOSIROT. PRAS26 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet
Magnetic Angle Sensors Magnetic Angle Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part of any quotation or
More informationData sheet VIPA CPU 115DP (115-6BL22)
Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO
More informationMHAD 50 - HDmag. Features
MHAD 50 with cable Features Absolute encoder with magnetic sensing and without bearings Absolute resolution max. 16 bit singleturn Additional incremental signals Robust and wearless Protection IP 67 Large
More informationTM241CEC24R controller M IO relay Ethernet CAN master
Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationL-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)
L-LAS Series - Visible laser spot (red), class 2 laser product - Reference distance 55 mm - Measuring range typ. 10 mm, resolution typ. 0,01 mm - Integrated interference filter / red light filter - CCD
More informationProximity sensors SME-8, for T-slot Technical data Magnetic reed
Function e.g. N/O contact, with cable, 3-wire Magnetic reed measuring principle Insertable in the slot lengthwise e.g. N/O contact, with plug, 3-pin SME-8-SL Sturdy thanks to long guides Plug directly
More informationlumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO
Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS Flat wall mounted lighting controller Universal mounting plate compatible with any electrical backbox MINI-USB connection for software programming
More informationSystem description SLIO
10 Appendix Software Solutions System description System description Structure and Concept stands for Slice I/O. The system is very compact and can be adapted piecemeal exactly to the requirements of the
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationMore Precision. colorsensor // Colour Sensors, LED Analyzers
More Precision colorsensor // Colour Sensors, LED Analyzers 30 Colour sensors for special surfaces colorsensor OT-3-LU - Colour sensor for fluorescent objects - 31 colours can be saved - UV illumination
More informationData sheet CPU 315SB/DPM (315-2AG12)
Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationBOS 73K... BOS 74K...
BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More informationFIS Part Number
Scanner 1D/2D Code Scanner FIS-0004-0101 Part Number for static applications High depth of focus Teach-In Technical Data Optical Data Medium density 36...132 mm Resolution 640 480 Pixel Light Source Red
More informationGSV-3USBx2 3,5mV/V 4,2V
x2 3,5mV/V 4,2V Highlights Powered via USB port Sampling rate 10 khz Data rate 1...1000 Hz straingage quarter, half, full bridges Built-in bridge supplement 350 Ohm Optionally also for displacement transducers
More information