Vevo770 Ultrasound. Quick Operation Guide AIPT
|
|
- Arthur Owens
- 6 years ago
- Views:
Transcription
1 Vevo770 Ultrasound Quick Operation Guide
2 Vevo770 Probe head (707B/704) Preparation The acoustic membrane is very fragile and sensitive, it must be handled with care. The probe head should be filled with water all the time. If it has been drained; follow the procedures on this page. Position the RMV scan head with the fill port pointing upward. Fill the nosepiece with de-ionized water using the supplied water bottle until the nosepiece is almost full. Using your thumb, cover the fill port and tap the scanhead several times to dislodge any air bubbles in the nosepiece. Check to ensure that the face of the transducer does not contain bubbles. If bubbles appear, tilt the RMV scanhead to dislodge them. Orient the nosepiece so that the remaining air bubbles are placed under the fill port, and finish filling the nosepiece with the syringe. Insert and tighten the fill port screw with a screwdriver. Do not over-tighten the fill port. Real-Time Microvisualization (RMV) Scan Head Fill Port Screw Nosepiece Transducer Acoustic Membrane Nosepiece Pressure fit groove RMV cable Transducer Arm Acoustic Window
3 Pre-Image Preparation-Animal Preparation Warm up the stage The stage warmer, heart and temperature monitors each have a simple on/off button on the control pad. Located on the table to the left of the stage Turn on the stage heater-this helps to maintain mouse body temperature Study Subject Preparation ultrasound is most effective with no hair. Depilate the scan area of the animal using a razor or depilatory cream (Nair) Be sure to remove the NAIR as it can easily burn the mouse Put electrode contact gel (Sigma) or imaging gel on all 4 of the foot pads on stage base. Tape mouse down on platform so that all four of its feet are on the appropriate foot pad and in contact with the probe. This will monitor the mouse s heart rate and respiration the heart rate should be between approximately 370 and 400 beats per minute Prior to placing imaging gel on the mouse, take a small amount of gel and smooth it over the surface of the image area to remove small air bubbles at the skin level. Place 1-2 inches of gel on the image area, lower the scan head into the gel. Make sure to avoid bubbles. 3
4 Set up a study Turn on the instrument and computer The system main power switch is a large toggle switch on the back right hand side of the image.r PC power is activated by small toggle switch on the left side of the unit near the DVD drive-if this switch is not working, the main computer power button is below the console. Each user will log on to VEVO770 using your Kerberos username and password. You will be billed for the greater of your reserved time or your logged time. Please have the Menu same person make reservations and log on/off of the instruments. Open the Visual Sonics program, from the desktop icon If an error code comes up simply click okay. Initialize scan head Select or add operator Set up new study, click the New tab Fill in spaces for user and project info Select scanning mode from the keypad B-mode: basic scanning, two dimensional images and cine loops. Doppler Mode: measures velocity of blood flow from a field of view (FOV). Power Doppler: measures flow volume or noise in 2 or 3-D from an FOV. Study Information Scan head initialization Study Browser New Study Scan Head selection (use default) Initialize Add Operator 4
5 Image acquisition/saving For all modes, start imaging in B-mode to identify an area of interest. If you want to have respiration and cardiac information included in the session, press the view tab on the tools menu. On the left side of the screen uncheck box for cardiac mode, with cardiac mode on, images will vibrate. Select the desired features. To save a single image select Frame Store, press Ctrl +L to label and save data. Menu tab View To save a video loop up up to 300 frames press Scan Freeze ; this tab will both start and stop data acquisition. The last 300 frames will be saved, to save the data press Cine Store then Ctrl +L to label and save the movie. At the conclusion of your study, in the Tool menu Study tab Close Study; Commit Session Data tab to save. -Data location is Data D: vevo770 \data\(your files) 5
6 Data transfer to the CCRBI2 server Data Transfer to the server -To transfer your data to the ccrbi2 file server you will need to map the drive as follows: Computer>tools>map network drive In the folder line type the following: \\ccrbi2\ccrbi2_data1\atwai\ (there is an underscore between ccrbi2 and Data1, not just a space) You will be asked for a username and password User name: ccrbi2\malstrom Password: Ray4eiph 6
7 B-Mode: basic scanning, two dimensional images and cine loops The line in this icon corresponds to the orientation ridge on the RMV scanhead and indicates the orientation of the RMV scanhead relative to the image. B-Mode ultrasound image window. The time-gain compensation (TGC) sliders specify the receive gain to be used for acquiring different sections of a B-Mode image. To toggle between the basic and detailed display parameters views, click Details or press <Ctrl+D>. The depth ruler indicates the depth from the transducer face. The triangular arrow indicates the focal length of the transducer. The grayscale bar indicates the dynamic range of the display. Cine loop playback controls. Physiological Data trace. The cine loop range control slider defines a subset of the cine loop to be played back or saved. 7
8 Define a Field of View (FOV) for PW Doppler studies Defining the Sample Volume and Doppler angle must be done in B-Mode. Defining the PW Doppler Sample Volume. Select Overlay > PW Doppler Sample Volume Wire-frame Move the trackball cursor over the red vertical line, left up click to move sample volume The trackball cursor is displayed as a crosshair when it is within a region that can be repositioned. Left-click the position line. Use the trackball cursor to move the overlay. Left-click again to place the Sample Volume. The Sample Volume details are updated in the parameters display. Defining the PW Doppler Angle. Start acquiring B-Mode data. From the B-Mode window, position the trackball cursor over the PW Doppler angle line (displayed as a dotted yellow or blue line). The trackball cursor changes to a crosshair. Right up-click to activate editing of the PW Doppler angle line. The angle line follows the movement of the trackball cursor. When the angle is at the desired setting, right-click to set the angle. VisualSonics recommends a PW Doppler angle that is between 0 and 60 for the most accurate velocity estimate. PW Doppler Sample Volume positioning line PW Doppler angle PW Doppler Sample Volume 8
9 PW Doppler Mode: measures velocity of blood flow from a field of view (FOV) Scout window Sample Volume position Angle measurement The frequency Scale indicates the frequency shift in the acquired PW Doppler signal. The grayscale bar indicates the dynamic range of the display. Time scale in milliseconds The image area is a right-to-left scrolling display. The most recently acquired data appears on the right of the window. ECG trace The velocity scale indicates the velocity of the measured PW Doppler signal. 9
10 Power Doppler: measures flow volume or noise in 2 or 3-D from an FOV. Priority indicator Time-gain compensation (TGC) sliders Gray-scale bar Power Doppler Acquisition Parameters Power Doppler Histogram 10
Quick Start Guide to the Vevo 770
Quick Start Guide to the Vevo 770 PN 11422 This Quick Start Guide provides a quick overview of the Vevo 770 and provides tips to allow users to start using the instrument and its various modes. A detailed
More informationQuick Start Guide to the Vevo 770
Quick Start Guide to the Vevo 770 PN 11422 This Quick Start Guide provides a quick overview of the Vevo 770 and provides tips to allow users to start using the instrument and its various modes. A detailed
More informationBeginner s Guide to Vevo 2100
PN 12090 Beginner s Guide to Vevo 2100 December 2008 This Beginner s Guide to Vevo 2100 provides a quick overview of the Vevo 2100 imaging modes and provides key tips to allow users to start a study, acquire
More informationVisualsonics Vevo2100: Manual for Collecting RF Data. Updated: 10/29/2012 M Kurowski
Visualsonics Vevo2100: Manual for Collecting RF Data Updated: 10/29/2012 M Kurowski 1 : System Start-Up/Shutdown 1.1 The Visualsonics mvevo2100 system must be the only device plugged into an outlet; failure
More informationImaging Guide Pancreatic Imaging
Imaging Guide Guide to Small Animal Pancreatic Imaging using the Vevo 2100 Imaging System Ver 1.0 Guide to Small Animal Pancreatic Imaging using the Vevo 2100 Imaging System Course Objectives: This guide
More informationVisualSonics Vevo 770 High-Resolution Imaging System. Operator Manual
VisualSonics Vevo 770 High-Resolution Imaging System Operator Manual VisualSonics Vevo 770 High-Resolution Imaging System Operator Manual January 2006 PN 11322 Revision 1.3 V1.3 VisualSonics Vevo 770
More informationQuick reference guide. MyLab50
Quick reference guide MyLab50 Quick reference guide MyLab50 Introduction This Quick Guide describes only the basic operating procedures for the diagnostic ultrasound MyLab50 Family, named in the following
More informationVEVO 1100 Sole Source Specifications
VEVO 1100 Sole Source Specifications Table of Contents 1.SYSTEM... 2 1-1 Licensing for the User... 2 1-2 Safety... 2 1-3 Portability... 2 2.TRANSDUCERS... 2 2-1 MicroScan transducers... 2 3. IMAGING STATION...
More informationSemi-Interactive Console Layout and Instructions
Semi-Interactive Console Layout and Instructions A video of the SIC accompanies these instructions, which you may refer to for further understanding. Click here to open the video link. NOTE: The images
More information10 Working With Setup Tools
10 Working With Setup Tools The Setup window allows you to set defaults and control various functions of the Terason software. The Setup window tabs display sets of controls for defaults and other settings.
More information10 Working With Setup Tools
10 Working With Setup Tools Setup Tools Overview The Setup window allows you to set defaults and control various functions of the Terason software. The Setup window tabs display sets of controls for defaults
More informationVisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents
VisualSonics Application Protocol 3D Tumor Imaging using the MicroMarker Non-Targeted Contrast Agents 1 Objective Part Number: 11902 The objective of the 3D Tumor Imaging using the MicroMarker Non-Targeted
More informationACUSON P300 Ultrasound System Control Panel Diagram
www.siemens.com ACUSON P300 Ultrasound System Control Panel Diagram 1 Power On / Off 1 2 TGC Controls 3 Left Mouse Click 4 Action 4 7 5 Right Mouse Click 6 Trackball 2 3 6 5 8 7 Pointer 8 Freeze 16 Color
More informationMyLab Alpha Quick Start
MyLab Alpha Quick Start Basic Setup The system has a 2.5 minute start time, but can be put in standby mode to allow for an 8 second boot time. From the patient data screen, click on the Menu button Then
More informationQuick Guide. EPIQ 7 Ultrasound System. English
Quick Guide EPIQ 7 Ultrasound System English Contents For easy reference, each section is color-coded. The color of each section title correlates with the color band on each page in that section. Controls
More informationSONOLINE G40 ultrasound system
SONOLINE G40 ultrasound system Quick Scan Card: General/OB For system software version 2.0 Press the Power Switch on the upper left side of the keyboard. A blue light will indicate the power is on. Getting
More informationEcho Blaster 64/128 and LogicScan 64/128 Series Ultrasound Systems Echo Wave II Software User Manual
Echo Blaster 64/128 and LogicScan 64/128 Series Ultrasound Systems Echo Wave II Software User Manual Internet page: http://www.telemed.lt Information E-mail: info@telemed.lt Ultrasound Medical Systems
More informationDataHub: FAQs/Troubleshooting
On the Ward s DataHub... = Select key = On/Off and ESC key = Scroll key 1. How do I pair my DataHub with a Windows computer? 2. How do I pair my DataHub with an Apple Macintosh (Mac) computer? 3. How do
More informationSONOS 7500/5500 Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision D.1
SONOS 7500/5500 Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision D.1 User s Guide Using 3-Dimensional and BiPlane Imaging And Other System Changes for Software Revision
More informationTELEMED. Echo Wave II Software LB-2. Ultrasound Consolle. User Manual
SmartUs - ClarUs - LS128 - LS64 - Echo Blaster 64 - Echo Blaster 128 Echo Wave II Software LB-2 Ultrasound Consolle User Manual T E L E M E D Ultrasound Medical Systems Telemed Medical Systems WEB: Telemed
More informationQuick Guide Software Version 4.4
Quick Guide Software Version 4.4 On-Call Clinical Consultants 1-888-FUJIMED We re here to assist you with questions about operating your equipment. Locating a Study in Worklist 1. Double-click the Synapse
More informationMedical Image Viewer Guide
Cloud Medical Image Management Medical Image Viewer Guide March 2016 Table of Contents Indications for Use 3 Browser Requirements 3 User Interface Overview 4-5 Study Page 6 Main Toolbar 7 Sub-Toolbars
More informationTutorial - Introduction to LabScribe and the IX-ELVIS
Tutorial - Introduction to LabScribe and the IX-ELVIS Background In addition to its prototyping capabilities, the iworx Bioinstrumentation Breadboard for the National Instruments Educational Laboratory
More information1 About the Terason Ultrasound System
1 About the Terason Ultrasound System Overview The Terason Ultrasound System is an easy-to-use, portable ultrasound system that produces high resolution images. The microminiaturized ultrasound system
More informationRecipes4Success. Draw and Animate a Rocket Ship. Frames 5 - Drawing Tools
Recipes4Success You can use the drawing tools and path animation tools in Frames to create illustrated cartoons. In this Recipe, you will draw and animate a rocket ship. 2012. All Rights Reserved. This
More informationNikon A1-B Confocal Operating Manual. Start-up. Microscope
Nikon A1-B Confocal Operating Manual Start-up 1. Turn on Excite 120 LED power supply. a. No need for cool down as for mercury bulb b. Open shutter by pushing down contol knob. c. Adjust intensity by turning
More informationZeiss Efficient Navigation (ZEN) Blue Edition Standard Operation Protocol
Faculty Core Facility ZEN BLUE 2.3 SOP A-1 Zeiss Efficient Navigation (ZEN) Blue Edition Standard Operation Protocol Faculty Core Facility ZEN BLUE 2.3 SOP A-2 A. Content Overview. 3 Start up. 4 Display
More informationKids 'n Vue. User's Guide
Kids 'n Vue User's Guide Table of Contents Registration...3 Receiving registration code...3 Entering registration code...5 Registration Screen...8 Registration Accepted Screen...9 Registration Email...10
More informationVEVO 2100 Sole Source Specifications
VEVO 2100 Sole Source Specifications Table of Contents 1.SYSTEM... 2 1-1 Licensing for the User... 2 1-2 Safety... 2 1-3 Portability... 2 2.TRANSDUCERS... 2 2-1 MicroScan transducers... 2 3. IMAGING STATION...
More informationAmbra User Guide. If you need help. Ambra Support (any time)
If you need help Ambra Support 888 315 0790 (any time) support@ambrahealth.com Ambra User Guide Envision Radiology, a Health Images Organization, has provided a list of your site s personnel that need
More informationGet to Know the VideoStudio Workspace
Get to Know the VideoStudio Workspace This written tutorial is a handy guide to understanding the various components of the VideoStudio interface. We will review the Capture, Edit and Share workspaces
More informationSmall rectangles (and sometimes squares like this
Lab exercise 1: Introduction to LabView LabView is software for the real time acquisition, processing and visualization of measured data. A LabView program is called a Virtual Instrument (VI) because it,
More informationUsing LoggerPro. Nothing is more terrible than to see ignorance in action. J. W. Goethe ( )
Using LoggerPro Nothing is more terrible than to see ignorance in action. J. W. Goethe (1749-1832) LoggerPro is a general-purpose program for acquiring, graphing and analyzing data. It can accept input
More informationZLog Z6R Altitude Data Recording and Monitoring System
ZLog Z6R Altitude Data Recording and Monitoring System 2014-04-28 Page 1 of 24 Introduction ZLog was designed to provide a lightweight, compact device for measuring and recording altitude over time. It
More informationVoxar 3D ColonMetrix. Reference Guide
Voxar 3D ColonMetrix Reference Guide The software described in this document is furnished under a license, and may be used or copied only according to the terms of such license. Toshiba means, Toshiba
More informationInstructions for Doppler Image Cropping code
Instructions for Doppler Image Cropping code The following instructions are for cropping Doppler E-and A-waves and make it ready for PDF analysis (using LabVIEW). The program allows the user to mark time
More information1 Place the iworx/214 unit on the bench, close to the computer. 3 When the dialog box appears, select ahk214.iws and then click Load.
Experiment 1: LabScribe a Tutorial LabScribe allows data to be accumulated, displayed and analyzed on a computer screen in a format similar to a laboratory strip chart recorder. Equipment Setup 1 Place
More informationThe LabScribe Tutorial
The LabScribe Tutorial LabScribe allows data to be accumulated, displayed and analyzed on a computer screen in a format similar to a laboratory strip chart recorder. Equipment Setup 1 Place the iworx unit
More informationExperiment 1: The LabScribe Tutorial
Experiment 1: The LabScribe Tutorial LabScribe allows data to be accumulated, displayed and analyzed on a computer screen in a format similar to a laboratory strip chart recorder. Equipment Setup 1 Place
More informationRemotely Accessible Healthcare at Home. User Guide for Devices
RAH@H A Patient Centric 24/7 Connected Health Model to Improve Healthcare Outcomes through Technology for Education, Engagement, Empowerment, Monitoring & Treatment of Patients Virtually User Guide for
More informationCapstone Appendix. A guide to your lab computer software
Capstone Appendix A guide to your lab computer software Important Notes Many of the Images will look slightly different from what you will see in lab. This is because each lab setup is different and so
More informationGallios TM Quick Reference
Gallios TM Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic
More informationOn Call Imaging Specialists. We re here to assist you with questions about operating your equipment. Pocket Quick Guide. Software version 3.2.
On Call Imaging Specialists 1800 060 209 We re here to assist you with questions about operating your equipment. Pocket Quick Guide Software version 3.2.1 Locating a Study in Worklist 1. Double Click the
More informationManual. User Reference Guide. Analysis Application. Cardiac Impedance (IMP) Customer Support: Phone: (888)
Phone: (888) 765-9735 WWW.MINDWARETECH.COM User Reference Guide Analysis Application Manual Cardiac Impedance (IMP) Copyright 2014 by MindWare Technologies LTD. All Rights Reserved. Phone: (614) 626-4888
More informationYou need to use the URL provided by your institute s OMERO administrator to access the OMERO.web client.
1 OMERO.web Client Using OMERO.web to view and work with image data via a web browser. You need to use the URL provided by your institute s OMERO administrator to access the OMERO.web client. Logging in,
More informationENVI Classic Tutorial: A Quick Start to ENVI Classic
ENVI Classic Tutorial: A Quick Start to ENVI Classic A Quick Start to ENVI Classic 2 Files Used in this Tutorial 2 Getting Started with ENVI Classic 3 Loading a Gray Scale Image 3 Familiarizing Yourself
More informationBD CellQuest Pro Acquisition Tutorial
BD CellQuest Pro Acquisition Tutorial Introduction This tutorial guides you through a CellQuest Pro Acquisition run like the one demonstrated in the CellQuest Pro Acquisition Movie on the BD FACStation
More informationMini Mini GlobiLab Software Quick Start Guide
Mini Mini GlobiLab Software Quick Start Guide This Guide is intended to help you get your Mini up and running quickly. For more detailed instructions, please see the Getting to Know Your Mini document
More informationVisual Physics - Introductory Lab Lab 0
Your Introductory Lab will guide you through the steps necessary to utilize state-of-the-art technology to acquire and graph data of mechanics experiments. Throughout Visual Physics, you will be using
More informationOptimizing GRITS. In this chapter:
Optimizing GRITS In this chapter: Creating Favorites and Shortcuts Optimizing Browser Performance Running Reports with Acrobat Reader Efficient Screen Navigation Creating Favorites and Shortcuts To access
More informationStudent Quick Reference Guide
Student Quick Reference Guide How to use this guide The Chart Student Quick Reference Guide is a resource for PowerLab systems in the classroom laboratory. The topics in this guide are arranged to help
More informationSF-1 Wireless Backfat & Loin Depth Scanner OPERATORS MANUAL
SF-1 Wireless Backfat & Loin Depth Scanner OPERATORS MANUAL Content Section 1 INTRODUCTION... 1 1.1 SPECIALIST... 3 Section 2 GETTING STARTED... 5 2.1 UNPACKING... 5 2.2 INSTALLING APP... 7 2.3 STARTING
More informationAdobe Flash CS4 Part 4: Interactivity
CALIFORNIA STATE UNIVERSITY, LOS ANGELES INFORMATION TECHNOLOGY SERVICES Adobe Flash CS4 Part 4: Interactivity Fall 2010, Version 1.0 Table of Contents Introduction... 2 Downloading the Data Files... 2
More informationRoof Designer USER S GUIDE
Roof Designer USER S GUIDE Roof Designer-1 Roof Designer-2 Roof Designer The Roof Designer makes it easy to define and place custom roofs in your project. You can start the Roof Designer independently,
More informationPONEMAH V5.30 WITH NOLDUS MEDIA RECORDER 4.0 QUICK START GUIDE
TECHNICAL NOTE PONEMAH V5.30 WITH NOLDUS MEDIA RECORDER 4.0 QUICK START GUIDE DSI has partnered with Noldus Information Technology, the leading solution provider for human and animal behavioral research
More informationGUIDE TO View3D. Introduction to View3D
View3D Guide Introduction to View3D... 1 Starting Hampson-Russell Software... 2 Starting View3D... 4 A Brief Summary of the View3D Process... 8 Loading the Seismic and Horizon Data... 8 Viewing the Data...
More informationCELLQuest Acquisition Tutorial
CELLQuest Acquisition Tutorial Introduction This tutorial guides you through a CELLQuest Acquisition run like the one demonstrated in the CELLQuest Acquisition Movie on the FACStation Overview CD-ROM.
More information연구용유방초음파질관리 원광대학병원김혜원
연구용유방초음파질관리 원광대학병원김혜원 Why US QC? Quality control (QC) testing of ultrasound scanners is important to verify the proper and consistent operation of these devices. main goal ; quality improvement Guidelines
More informationKNOBOLOGY. Jamie Ternes, RVT William Beaumont Hospital Royal Oak, Michigan. From the Beginning
KNOBOLOGY Jamie Ternes, RVT William Beaumont Hospital Royal Oak, Michigan From the Beginning Power On/Off Patient information Presets Probe selection Scan 1 Modalities /Gray scale/2d Pulse Wave Doppler
More informationLiving Image Software
Living Image Software User s Manual Version 3.1 2002-2008 Xenogen Corporation. All rights reserved. PN 124908 Xenogen Corporation 68 Elm Street Hopkinton, MA 01748 USA 1.877.522.2447 (US) 1.508.435.9500
More informationHow To Manually Update QuickBooks Point of Sale 2013 In A Multi User Environment To The Most Current Release Via Intuit s Website
There will come a time when you may need to manually update QuickBooks Point of Sale 2013 manually via downloading the most current release from Intuit s website. This will usually need to be done when
More informationTHE EASTMAN Easicut v2.1
THE EASTMAN Easicut v2.1 User's Manual This manual must be used in conjunction with the M9000 Machine Instruction and Service manual, Form #E-509-Instructions. 779 Washington St., Buffalo, N.Y. 14203-1396
More informationGE Medical Systems Training In Partnership LOGIQ 400. Quick Start Guide A Training in Partnership Program
GE Medical Systems Training In Partnership LOGIQ 400 Quick Start Guide 2237879 100 A Training in Partnership Program TiPTM Regulatory Requirement This product complies with regulatory requirements of
More informationWATER MAZE VIDEO TRACKING
instrumentation and software for research SOF-845 USER S MANUAL DOC-214 Rev. 2.2 Copyright 2016 All Rights Reserved Med Associates Inc. P.O. Box 319 St. Albans, Vermont 05478 Phone: 802.527.2343 Fax: 802.527.5095
More informationStep-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform
Step-by-Step Data Acquisition Part II Exercise 2: Generating an Analog Output Waveform In this exercise, you will use the DAQ Assistant to build a LabVIEW VI that generates and outputs an analog waveform.
More informationSynapse Quick Guide PACS
The FUJIFILM UK Limited Pension and Life Assurance Scheme provides a range of benefits that are competitive when compared with those of other UK companies. The benefits are designed to ensure that you
More informationAppendix E: Software
Appendix E: Software Video Analysis of Motion Analyzing pictures (movies or videos) is a powerful tool for understanding how objects move. Like most forms of data, video is most easily analyzed using a
More informationOptimizing ImmuNet. In this chapter: Optimizing Browser Performance Running Reports with Adobe Acrobat Reader Efficient Screen Navigation
Optimizing ImmuNet In this chapter: Optimizing Browser Performance Running Reports with Adobe Acrobat Reader Efficient Screen Navigation Optimizing Browser Performance Unless instructed to do otherwise,
More informationQuick guide. Remote control. What it does How to do it Usability tips. Touch the glider gently, no need to press it. your thumb
Quick guide Remote control What it does How to do it Usability tips Move the cursor Touch the Bird glider with your thumb Touch the glider gently, no need to press it To adjust the cursor sensitivity at
More informationIOP Horizons in Physics. Department of Physics University of Limerick
IOP Horizons in Physics Department of Physics University of Limerick 1 Import Video Using the Video tab Import the video you want to analyse. Your video may not have the correct orientation. If so filters
More informationUser Manual Version 1.1 January 2015
User Manual Version 1.1 January 2015 - 2 / 112 - V1.1 Variegator... 7 Variegator Features... 7 1. Variable elements... 7 2. Static elements... 7 3. Element Manipulation... 7 4. Document Formats... 7 5.
More informationBioIRC solutions. CFDVasc manual
BioIRC solutions CFDVasc manual Main window of application is consisted from two parts: toolbar - which consist set of button for accessing variety of present functionalities image area area in which is
More informationExercise 4a: Creating and Editing XY Plots
Exercise 4a: Creating and Editing XY Plots This exercise uses the data file, LINACC. Step 1: Load the file LINACC and create multiple plots. 1. Open HyperWorks Desktop and set the application to HyperGraph
More informationPortable ultrasonic image diagnosis. Simple operating instruction Rev.2.5
300C Portable ultrasonic image diagnosis Simple operating instruction Rev.2.5 Sonon 300C Usage Introductions SONON 300C is developed and manufactured by HEALCERION and if additional information or support
More informationNORDSON CORPORATION AMHERST, OHIO USA
CanWorks Operator Interface Tracking PLUS for CanWorks Systems with SM-2 Spray Monitors User Guide Part 1018132A NORDSON CORPORATION AMHERST, OHIO USA 2002 Nordson Corporation. All rights reserved. CanWorks,
More informationPropel PRO User Guide
Propel PRO User Guide Propel PRO Version 3.2.0a Page 1 Welcome to the latest version of Propel PRO which offers fast performance and easy navigation. Please refer to this user guide for common features
More informationVI ViewerPlus Copyright 2018 Panasonic System Solutions Company of North America Version Last updated:
VI ViewerPlus Copyright 2018 Version 7.3.0 Last updated: 11.15.2018 Panasonic VI ViewerPlus TABLE OF CONTENTS TABLE OF CONTENTS... 0 OVERVIEW... 1 USER INTERFACE... 1 WORKSPACE... 2 LAYOUTS... 2 Setting
More informationUniversity of Minnesota Nano Fabrication Center Standard Operating Procedure
Equipment Name: University of Minnesota Nano Fabrication Center Coral Name: hs-scope Revision Number: 1.5 Model: HS200A Revisionist: M. Fisher Location: Bay 1 Date: 9/12/2013 1 Description The Hyphenated
More informationContents... 1 Installation... 3
Contents Contents... 1 Installation... 3 1 Prerequisites (check for.net framework 3.5)... 3 Install Doctor Eye... 3 Start Using Doctor Eye... 4 How to create a new user... 4 The Main Window... 4 Open a
More informationBioBeat User Guide. Warning
www.i-cubex.com BioBeat User Guide Warning The BioBeat sensor is to be used only with extreme caution according to the following instructions. It is intended for research purposes only and not intended
More informationPersonalize your pen with a color ring
Work with your pen All pen tablets and pen displays include a cordless, battery-free pen that you use to interact with your device. You can hold, write, and draw as you normally would with a pen or pencil.
More informationComputer Basics. Page 1 of 10. We optimize South Carolina's investment in library and information services.
Computer Basics Page 1 of 10 We optimize South Carolina's investment in library and information services. Rev. Oct 2010 PCs & their parts What is a PC? PC stands for personal computer. A PC is meant to
More informationAlienware Elite Gaming Mouse AW958. User Guide
Alienware Elite Gaming Mouse AW958 User Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential
More informationTABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 USING WORD S MENUS... 3 USING WORD S TOOLBARS... 5 TASK PANE... 9
TABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 USING WORD S MENUS... 3 DEFINITIONS... 3 WHY WOULD YOU USE THIS?... 3 STEP BY STEP... 3 USING WORD S TOOLBARS... 5 DEFINITIONS... 5 WHY WOULD
More informationFREQUENTLY ASKED QUESTIONS
FREQUENTLY ASKED QUESTIONS Poor Contact message appears on the smartphone This message indicates poor contact between your skin, the monitor and Strip. It is NOT related to the Bluetooth or cellular connection
More informationImage Optimisation. -How to Get the Most out of your Echo Machine. Katarina Winkler, Biomedicinsk analytiker, Barnhjärtcentrum i Lund
Image Optimisation -How to Get the Most out of your Echo Machine analytiker, Barnhjärtcentrum i Lund Image Optimisation Helpful tips to improve the 2D-Image and Doppler registrations. Common adjustments
More informationNewVission Portable Interactive Pad
NewVission Portable Interactive Pad U-15WF User Guide Contents I. General Information... 1 1. Overview... 1 2. Pen Tablet Functions... 1 3. System Requirements... 1 4. Installing the Driver Software on
More informationWindows 10 - Starter Guide
Windows 10 - Starter Guide Logging on When the logon screen appears press Ctrl + Alt + Delete then OK. Enter your password then press Enter. Note: Your username does not need to be entered unless switch
More informationScanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A
NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter
More informationApplied Biosystems Attune Cytometric Software version 1.2 Release Notes
Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune Cytometric Software version 1.2 ( Attune Software
More informationFor the Beginner: c) Click the settings tab to set screen resolution d) Set resolution with slider bar.
For the Beginner: Preparing and Logging In to Run JobSite OnLine 1) Jobsite works best with a screen resolution of at least 800 x 600 preferably 1024 x 768. To set this, follow the instructions below.
More informationOverview of Synaptics TouchPad Features
Overview of Synaptics TouchPad Features Your Synaptics TouchPad is much more powerful than an old-fashioned mouse. In addition to providing all the features of an ordinary mouse, your TouchPad allows you
More informationIntroduction to Computers By Jennifer King, YA and Marketing Librarian, Great Bend Public Library
Introduction to Computers By Jennifer King, YA and Marketing Librarian, Great Bend Public Library Welcome and Introduction To better understand how to use computers, this course will teach you some basic
More informationQuick Start guide. for windows and mac. creative learning tools. Kar2ouche Quick Start Guide Page 1
Quick Start guide for windows and mac creative learning tools Kar2ouche Quick Start Guide Page 1 Step 1: The Activity Screen Open a Kar2ouche title by double clicking on the icon on your desktop. You will
More informationUSER'S GUIDE 4/25/2013
USER'S GUIDE 4/25/2013 2 P&O Clinical Movement DATA Table of Contents Part I Introduction 5 1 Welcome... 5 2 Overview... 5 3 Activating... your Software 6 4 Quick Start... 8 Part II Getting around the
More informationWizard PDS. Automated Perimeter Definition System. January Education and Training Center Wizard Date 5/4/2016. Page 1
PDS Automated Perimeter Definition System January 2016 Page 1 Table of Contents Information Page 3 O Page 32 Operating Procedures Basic Operation Manually Reposition a Truss Snap to Rail Centerline Flip
More informationDigital Recorder End User Guide. Official UK distribution partner
Digital Recorder End User Guide Official UK distribution partner 2 Installer Information Contents General Operation Mouse Operation Logging into the System Quick Menu PTZ Control 4 5 5 6 Playback Operation
More informationSLS-ENVR4 Network Video Recorder V2.1 Quick Setup Guide
SLS-ENVR4 Network Video Recorder V2.1 Quick Setup Guide The SLS-ENVR4 series NVR is an intelligent and compact appliance that provides a network interface to monitor, record and playback video from up
More informationand Multiparameter Meters
and Multiparameter Meters 54650-23 ph Menu Options Table 1 How to Change ph Menu Options Setup Setup 1 Time Setup 2 Date Setup 3 Year Setup 4 Temperature Units Setup 5 Display Lock Setup 6 Measurement
More informationLSRFortessa Guide. Cell Evaluation and Therapy Core HO324
LSRFortessa Guide Cell Evaluation and Therapy Core HO324 Before Use: Prime the instrument twice with no tube and arm to the side Ensure that sheath is full and waste is empty To Begin: Log into ilabs tracker
More information