Owner s Manual PC Programmable Multi-Door Access Controller

Size: px
Start display at page:

Download "Owner s Manual PC Programmable Multi-Door Access Controller"

Transcription

1 Owner s Manual PC Programmable Multi-Door Access Controller DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 00 U.S.A. Phone: Fax: P/N -0 REV W, 0/ Copyright 00 DoorKing, Inc. All rights reserved.

2 Page -0-W-0-

3 Use this manual with the following models only. Model Access Controller, REV T or Higher DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc. -0-W-0- Page

4 TABLE OF CONTENTS Preface Important Notices... Important Information... Features... Section Installation. Installation Guidelines..... Mounting Information Memory Chip Installation... Section Wiring General Information.... Wiring Guidelines.... Terminal Identification.... Wiring Detail.. Controller Only..... Controller and Expansion Boards Controller and Expansion Boards Controller and -0 or - Remote Call Station..... Controller and Two () -0 or - Remote Call Stations Controller and 0-0 and 0- Remote Call Stations..... RS- Cable Connection..... Postal Lock Box Installation & Wiring... Section Programming. General Programming Information.. Programming with a PC..... Programming from the Keypad..... System Memory.... Programming with a PC.. Master Code..... Single or Multiple Systems..... Programming Resident Elevator Button Relay Time..... Open Tone On / Off..... Elevator Control Function..... RS- Speed Setting.... General Programming.. Relay Strike Time..... Talk Time..... Tone Open Numbers Input Switch Touch Tone / Rotary Dial.... Programming Phone Number.. Programming Directory Code Length..... Programming -Digit Phone Number..... Programming Number of Area Codes..... Programming Area Code..... Programming Phone Number with Area Code..... Delete Phone Number..... Delete Area Code..... PBX Line Access Code Programming..... Touch Tone Dialing Pause... Page -0-W-0-

5 . Device Codes.. Programming Device Codes..... Deleting Device Codes..... Enabling Facility Codes..... Programming Facility Codes.... Four-digit Entry Codes.. Programming Four-digit Entry Codes..... Delete Four-digit Entry Codes..... Entry Code Ranges.... Anti-Pass Back.. Programming Anti-Pass Back Mode..... Re-Sync All Devices..... Re-Sync Individual Devices..... Reset Facility Counter.... Control Board Adjustments.. Master Code Switch..... Ring Pin..... Relay Contact Pin..... Speaker Volume, Microphone and Feedback... 0 Section Operating Instructions. User Instructions.. Card Access..... RF Transmitters..... Five-Digit PIN Codes..... Four-Digit Entry Codes.... System Administrator.. Opening from a Remote Location..... Tracker Board Override Hold Open Command..... Relay Check... Section Maintenance and Trouble Shooting. Trouble Shooting..... RS- Test..... Floor, Elevator, Security Level Test Programming..... Elevator Board Hardware Test..... Elevator Board Floor Hardware Test..... Modem Output Level.... Accessories... Log Tables W-0- Page

6 IMPORTANT NOTICE FCC - UNITED STATES This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part of the FCC Rules and Regulations. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Registration Number: DUFVT--OT-T DOC - CANADA The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the users satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable means of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. DOC Registration Number: A Notice: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the load numbers of all the devices does not exceed 00. Notice: DoorKing does not provide a power transformer on units sold into Canada. Use only transformers that are CSA listed to power this entry system. The model requires a.-volt, 0 VA transformer. Listing: This product has been tested to and found to be in compliance with the U.L Safety Standard by Intertek Testing Services NA Inc. (a Nationally Recognized Testing Laboratory) and is ETL listed. Page -0-W-0-

7 IMPORTANT INFORMATION Prior to beginning the installation of the access control system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner. The proper installation of the access controller is an extremely important and integral part of the overall access control system. Check all local building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes. When used to control a door or pedestrian gate, try to locate the access controller as near as possible to the entry point. The unit should be mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates. Continuous vibration and shock from slamming doors or spring-loaded pedestrian gates will damage the circuit board. Under no circumstances should the unit be mounted directly to a moving door or gate. ADA mounting requirements for door control (Ref: ICC/ANSI A.-00).. Unobstructed Forward Reach. Where a clear floor or ground space allows only a forward approach to an object and is unobstructed, mounting height shall be a minimum of inches ( mm), and a maximum of inches (. m), above the floor or ground to the operable controls.. Obstructed High Forward Reach. If the high forward reach is over an obstruction greater than 0 inches, but less than inches, mounting height shall be a maximum of inches (. m) above the floor or ground to the operable controls.. Unobstructed Side Reach. Where a clear floor or ground space allows a parallel approach to an object and the side reach is unobstructed, and the edge of the clear floor space is 0 inches ( mm) maximum from the object, mounting height shall be a minimum of inches (0 mm), and a maximum of inches (. m), above the floor or ground to the operable controls.. Obstructed High Side Reach. If the side reach is over an obstruction greater than 0 inches, but less than inches, mounting height shall be a maximum of inches (. m) above the floor or ground to the operable controls. When used to control a vehicular gate with an automatic gate operator, the access control device (card reader, keypad, etc.) must be mounted a minimum of ten (0) feet away from the gate and gate operator, or in such a way that a person cannot operate the device and/or touch the gate or gate operator at the same time. Be sure that access control devices are installed so that they are not directly in the traffic lane. Gooseneck mounting post and kiosks work well for these type systems. When planning where to locate the access device, take into consideration traffic lane layouts, turn around lanes for rejected access, conduit runs, power availability, etc. This access system controller contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use. Discharge any static prior to removing the circuit board by touching a proper ground device. Instruct the end user to read and follow these instructions. UInstruct the end user to never let children play with or operate any access control deviceu. This Owner s Manual is the property of the end user and must be left with them when installation is complete. -0-W-0- Page

8 U FEATURES Can provide service for up to 000 system users. Can store up to 000 card, transmitter or digital PIN codes. Can interface with DKS Remote Call Stations to provide telephone communication and entry control (P/N -0, -). System can be programmed with a PC by modem, RS-, RS- (requires 0-0 adapters), a LAN connection (requires 0- TCP/IP kit) or via the internet using the Internet Modem Server (use of the IM Server is fee based. Visit for more information). Transaction buffer stores the last 000 events and has its own backup power source to retain memory during power outages. View LIVE Transactions. -security levels total (security level 00 always denies entry, security level 0 always admits entry), with programmable security levels, each with four time zones allows you to control and restrict user access as needed. Programmable holiday schedule. Facility codes can be enabled or disabled. Store up to 0 different facility codes. True Anti-Pass Back feature. Requires APB chip set. Two internal relays allow the system to control two entry points. System can be expanded to control up to entry points. Tracker expansion boards are required (one for each additional entry point) and are not included with the system. Tracker boards also provide output for door ajar and forced entry alarms. Optional elevator control board(s) can control up to four elevators with each elevator serving up to floors. System will interface with selected models of DKS DoorKing vehicular gate operators to provide gate operator information and data (requires a Tracker board for each gate operator that is to send data to the system). Page -0-W-0-

9 SECTION - INSTALLATION If you are going to use a telephone line with this controller, order it at least two weeks prior to the planned installation date. This will assure that a phone line is available when the unit is installed. The telephone company will require the following information from you: Type: Ringer Equivalence: Jack Type: FCC Registration (US): DOC (Canada): Electrical Listing: Touch Tone, Loop Start 0.0 A RJC DUFVT--OT-T A Complies with U.L. - ETL Listed.. Installation Guidelines. Open the cabinet of the access controller and disconnect the keypad ribbon cable from the main circuit board.. Remove the - x / round head screws from the right side of the circuit board.. Remove the circuit board by gently pulling it out of the main terminal edge connector. CAUTION - the circuit board contains static sensitive components. Discharge any static electricity from your hands by touching a proper ground device before removing the circuit board. Place the circuit board where it will not be damaged.. Mount the access controller cabinet using - screws. The access controller has four - blind pems installed in each corner. See page 0. Make any necessary conduit connections using the conduit knockouts provided on the bottom of the cabinet. DO NOT make any other conduit holes in the cabinet.. Route wiring into the cabinet. Do not apply any power at this time.. Clean out the cabinet. Be sure that all dirt, metal and/or wood debris is removed from the cabinet and that the terminal strip edge connector is clean and free of any loose particles.. Re-install the circuit board into the cabinet by gently pushing the circuit board terminals into the edge connector. CAUTION - the circuit board contains static sensitive components. Discharge any static electricity from your hands by touching a proper ground device before removing the circuit board.. Secure the circuit board to the cabinet using the screws removed in step.. Plug the keypad ribbon cable into the circuit board. The cable points to the left. WARNING! If this access control system is used to control a vehicular gate with an automatic gate operator, the access control device must be mounted a minimum of ten (0) feet away from the gate and gate operator, or in such a way that a person cannot operate the access control device and touch the gate or gate operator at the same time. -0-W-0- Page

10 .. Mount Information If used to control a door or pedestrian gate, try to locate the access controller as near as possible to the entry point. The unit should be mounted on a rigid wall to prevent excessive shock and vibration from closing doors or gates. Continuous vibration and shock from slamming doors or spring-loaded pedestrian gates will damage the circuit board. Under no circumstances should the unit be mounted directly to a moving door or gate text KO -Places. KO -Places DOORKING, INC., INGLEWOOD, CA 00 Title: Model Controller Mounting Dimensions Date: /0 Dwg. No. M-0- Rev. B Page 0-0-W-0-

11 . Memory Chip Information The is shipped with memory chips pre-installed. Do not remove or re-install the memory chips with power to the system turned on. Doing this will irrevocably damage the memory chips. Memory chips are static sensitive. Discharge any static electricity from your hands by touching a proper ground device before removing the control board or memory chips. Handle memory chips with care.. The large memory chip socket is colored black and is located in the center of the circuit board. Be sure that the handle is in the un-locked position (pointing up). Be sure that power to the telephone entry system is off.. Carefully insert the memory chip into the socket. The small half circular indentation on the chip must be to the right. CAUTION: Installing the memory chip backwards will cause permanent damage to the chip. Be sure that the memory chip is seated correctly in the socket, then move the lever to the locked position.. Install the small memory chip in the socket located at the bottom of the circuit board. The small circular indentation on the chip must be to the right. CAUTION: Installing the memory chip backwards will cause permanent damage to the chip. Be sure that the memory chip is seated correctly in the socket. Series Circuit Boards Memory Chip Location Dimple on chip must be towards the right! DOORKING, INC., INGLEWOOD, CA 00 Title: Date: Series Memory Chip Location /0 Dwg. No. M-0- Rev. A -0-W-0- Page

12 U Page -0-W-0-

13 SECTION WIRING Prior to installing wiring to the access control system, we suggest that you become familiar with the instructions, illustrations, and wiring guidelines in this manual. This will help insure that you installation is performed in an efficient and professional manner. The wiring of the access control panel is an extremely important and integral part of the overall access control system. Use proper wire for the communication line, power wires, and be sure that the system is properly grounded. Check all local building ordinances and building codes prior to installing this system. Be sure your installation is in compliance with local codes. WARNING: If this access control system is used to control a vehicular gate with an automatic gate operator, the access devices (card reader, keypad, etc.) must be mounted a minimum of ten (0) feet away from the gate and gate operator, or in such a way that the user cannot come into contact with the gate or gate operator when using the entry device. If the entry device has been installed closer to the automated vehicular gate, do not proceed with any wiring until the device has been moved and re-installed so that it is in compliance with these instructions. Use only the supplied transformers (or U.L. listed equivalent) to power the access control system and any wiegand input devices (. VAC, 0 VA). Do not power any other devices (electric strikes, magnetic locks, etc.) from these power transformers. For wire runs up to 00 feet, use AWG, 00 volt insulated wire. For wire runs up to 00 feet, use AWG, 00 volt insulated wire. Power wires are susceptible to noise and hum pickup; therefore it is preferable that you keep power wire runs as short as possible. This access control system contains a number of static sensitive components that can be damaged or destroyed by static discharges during installation or use. Discharge any static prior to removing the circuit board from the lobby panel by touching a proper ground device. If Tracker expansion boards are being used with this system, refer to the Tracker Installation and Wiring manual that came with the Tracker expansion boards, for detailed information on wiring Tracker boards to the PC programmable access control system. If Elevator Control is used with this system, refer to the Elevator Control Installation and Wiring manual for detailed information on wiring the elevator control boards to this system and to the elevator push button control panel.. -0-W-0- Page

14 . WIRING GUIDELINES Do not run high voltage ( V) power lines and communication lines in the same conduit. These should be in separate conduits at least six () inches apart. Be sure that all phone line wiring is twisted and completely isolated from ground. Use only the supplied. VAC (or U.L. listed equivalent) to power the access control system. Do not power any other devices (electric strikes, magnetic locks, lights, etc.) from this transformer. Do not run VAC access control system power lines over 00 feet. It is advisable to keep these wires as short as possible. Use AWG wire for wire runs up to 00 feet, and AWG wire for wire runs up to 00 feet. Install a low voltage surge suppresser (DoorKing p/n - 00 or equivalent) to help protect the entry system from power surges. Wiegand wire runs are 00-feet maximum. Use -conductor stranded wire with overall shield., 0, or gauge is sufficient for these connections. A volt. amp hour gel-cell battery (DoorKing p/n 0-00) can be installed in the system to provide stand-by power in the event of a power outage. Two batteries are required, one for the system power and one for the auxiliary terminal power. Proper grounding of this system is a requirement. The use of surge suppressers can significantly reduce the chance of component failure because of static charges or surges. To be effective, ground connections should be made with a minimum AWG, 00 volt insulated wire to a ground point within 0 feet of the access control system. The ground point must be at an electrical panel, a metallic cold water pipe that runs in the earth, or a stainless steel grounding rod driven at least ten (0) feet into the soil. Be sure that you use proper wire that has an insulation rated for an underground environment. All wires should be placed in conduits. Proper pre-planning can greatly ease the installation and wiring of this system. Always check with the local building code to determine the type of wire required in your municipality. The is shipped with two () Ferrite Filters. One is installed on the VAC power wires to the main circuit board (terminals -0). The second is installed and around the wires connected to the Auxiliary Terminal strip. To install the ferrite filter, simply snap the filter open, place the wires in the circular core, then snap the filter closed. VAC POWER AUX TERMINAL WIRES Page -0-W-0-

15 . TERMINAL DESCRIPTIONS MAIN DESCRIPTION Phone Line Connection 00 ft. maximum with AWG wire; 00 ft. maximum with AWG wire. Phone Line Connection 00 ft. maximum with AWG wire; 00 ft. maximum with AWG wire. Earth Ground Only. Switch Input. A closure between terminals and will cause the designated relay(s) to activate for the programmed strike time. The Postal Switch is connected here. Microphone Input. Common for switch input, A and Z input, speaker, microphone and battery negative. Speaker Output. Not Used. Not Used. 0 Not Used. Z Input. A closure between terminals and will dial the phone number stored under directory code, 0, 00 or 000. A Input. A closure between terminals and will dial the phone number stored under directory code 0, 00, 000 or Relay Common 0 Volt, Amp maximum. Relay Contact 0 Volt, Amp maximum. Relay Common 0 Volt, Amp maximum. Relay Normally Closed 0 Volt, Amp maximum. Relay Normally Open 0 Volt, Amp maximum. Microphone Power and Back-up Battery POSITIVE (connect negative to terminal ). VAC Input Power 0 VA minimum. 00 ft. maximum with AWG wire; 00 ft. maximum with AWG wire. 0 VAC Input Power 0 VA minimum. 00 ft. maximum with AWG wire; 00 ft. maximum with AWG wire. AUXILIARY VAC Input Power 0 VA. VAC Input Power 0 VA. Back-up Battery POSITIVE. Back-up Battery NEGATIVE. VAC for Card Reader lights only. VAC for Card Reader lights only. DATA 0 Card Reader. DATA Card Reader. COMMON Card Reader. 0 + VDC Power Card Reader. DATA 0 Card Reader. DATA Card Reader. COMMON Card Reader. + VDC Power Card Reader. ELEVATOR DESCRIPTION DESCRIPTION DATA connect to Elevator Control Board (-00) Terminal 0. DATA 0 connect to Elevator Control Board (-00) Terminal. COMMON connect to Elevator Control Board (-00) Terminal. -0-W-0- Page

16 . WIRING DETAIL.. Controller Only 0 Series Controller Detail Wiring RS Connection Elevator Control DATA DATA 0 COMMON 0 ELEVATOR CONTROL -00 Central Office phone line - touch tone, loop start. A switch closure across terminals & will activate relay for its programmed strike time. Battery Backup - separate batteries required for phone system and weigand terminals. Volt, 0 VA UL Listed Transformer.,,,, CONTROLLER Main Terminal NOTES: Relay 0 is not available on the controller. - VDC BATT INPUT + VDC BATT INPUT Relay 0 NO NC COM + VDC COMMON DATA DATA 0 + VDC COMMON DATA DATA 0 NEG VDC INPUT POS VDC INPUT Auxiliary Terminals 0 CARD RDR- 0 CARD RDR- VAC OUTPUT 0 VDC BATT VAC PWR INPUT RELAY 0 COMMON RELAY 0 NORMALLY CLOSED RELAY 0 NORMALLY OPEN For, use Volt, 0 VA UL Listed Transformer. conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. See Dwg No. M-0- for detail. See Elevator Control Board Manual -0 for detail. Aux power transformer must be connected. Otherwise, RS, elevator control and weigand inputs will not function. VAC output can be used to power lights on card readers that have additional lighting for outdoor use. Card reader connected to these terminals will operate Relay for its programmed strike time. Card reader connected to these terminals will operate Relay for its programmed strike time. Relay contact is set N.O or N.C. with a jumper on the circuit board. Electric strikes are wired to Normally Open (N.O.) contacts; magnetic locks are wired to the Normally Closed (N.C.) contacts. Power for electric strikes or magnetic locks is not provided by the system. Use a separate UL listed power supply. Auxiliary and Elevator Control terminals are not available on the controller. Use AWG wire for runs up to 00 Ft. Use AWG wire for runs up to 00 Ft. BASIC DOOR CONTROL LOCK PWR 0 VAC PWR INPUT To Control Relay DOOR LOCK C.O. PHN RELAY NORMALLY OPEN RELAY NORMALLY CLOSED RELAY COMMON To Card Reader Input CARD READER RELAY CONTACT RELAY COMMON DOORKING, INC., INGLEWOOD, CA 00 Title: Detail Wiring - 0 Series Controller Date: / Dwg. No. M-0- Rev. E Page -0-W-0-

17 .. Controller & Expansion Boards - 0 Series Controller to -00 Expansion Boards - Detail Wiring RS Connection Elevator Control,,, CONTROLLER Main Terminal NOTES: Controller main terminals -- = SYSTEM RELAY. Controller main terminals - = SYSTEM RELAY. - VDC INPUT + VDC INPUT Relay 0 NO NC COM + VDC COMMON DATA DATA 0 NEG VDC INPUT POS VDC INPUT Auxiliary Terminals 0 VAC OUTPUT + VAC PWR INPUT MAIN DR/GATE 0 LOCK PWR BRN BLU Board System Relay P 0-00 P BRN BLU DOOR LOCK VAC PWR INPUT Board System Relay P 0 BRN BLU -00 For, use Volt, 0 VA UL Listed Transformer. P BRN BLU 0 LOCK PWR DOOR LOCK VAC PWR INPUT To Boards - 0 C.O. PHN Volt, 0 VA UL Listed Transformer. Central Office phone line - touch tone, loop start. VAC PWR INPUT A switch closure across terminals & will activate relay for its programmed strike time. Battery Backup - separate batteries required for phone system and weigand terminals. 0 conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. No connection at controller. Communication cable to additional boards is connected in parallel. Allows teeing of communication cable for optimal cable routing. Power for door strikes or magnetic locks is not provided by the system. It must be provided by an external power supply. Aux power transformer must be connected. Otherwise, RS, elevator control and weigand inputs will not function. See Dwg No. M-0- for detail. Title: Date: DOORKING, INC., INGLEWOOD, CA 00 Detail Wiring - 0 Series Controller to -00 Expansion Boards - 0/ Dwg. No. M-0- Rev. D -0-W-0- Page

18 .. Controller & Expansion Boards - 0 Series Controller to -00 Expansion Boards - Detail Wiring RS Connection Elevator Control 0 LOCK 0 PWR DOOR LOCK LOCK PWR DOOR LOCK P P P P,,, CONTROLLER Main Terminal NOTES: Controller main terminals -- = SYSTEM RELAY. Controller main terminals - = SYSTEM RELAY. Relay 0 NO NC COM BRN + VDC COMMON DATA DATA 0 + VDC COMMON DATA DATA 0 BLU Auxiliary Terminals 0 VAC OUTPUT + VAC PWR INPUT To Main Door / Gate + BRN BLU BRN BLU 0-00 P 0-00 P BRN BLU BRN BLU 0 VAC PWR INPUT VAC PWR INPUT LOCK PWR For, use Volt, 0 VA UL Listed Transformer. DOOR LOCK BRN BLU BRN BLU 0-00 P 0-00 P BRN BLU BRN BLU VAC PWR INPUT 0 VAC PWR INPUT LOCK PWR To Boards - DOOR LOCK To Boards - 0 C.O. PHN BLU BRN VAC PWR INPUT Central Office phone line - touch tone, loop start. A switch closure across terminals & will activate relay for its programmed strike time. Battery Backup - separate batteries required for phone system and weigand terminals. Volt, 0 VA UL Listed Transformer. 0 conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. Aux power transformer must be connected. Otherwise, RS, elevator control and weigand inputs will not function. Communication cable to additional boards is connected in parallel. Allows teeing of communication cable for optimal cable routing. Power for door strikes or magnetic locks is not provided by the system. It must be provided by an external power supply. No connection at controller. See Dwg No. M-0- for detail. EARTH Ground. Title: Date: DOORKING, INC., INGLEWOOD, CA 00 Detail Wiring - 0 Series Controller to -00 Expansion Boards - 0/ Dwg. No. M-0- Rev. D Page -0-W-0-

19 .. Controller and -0 or - Remote Call Station RS Connection Elevator Control + VDC COMMON DATA DATA Card Reader Push To Call CONTROLLER VAC OUTPUT VAC OUTPUT NEG VDC INPUT POS VDC INPUT Auxiliary Terminals VAC PWR INPUT PUR ORG GRY LED Lights Speaker Microphone -0/ Central Office phone line - touch tone, loop start. A switch closure across terminals & will activate relay for its programmed strike time. Battery Backup - separate batteries required for phone system and weigand terminals. Main Terminal 0 C.O. PHN - VDC BATT INPUT + VDC BATT INPUT Relay 0 NO NC COM RELAY 0 COMMON RELAY 0 NORMALLY CLOSED RELAY 0 NORMALLY OPEN 0 VAC PWR INPUT RELAY NORMALLY OPEN RELAY NORMALLY CLOSED RELAY COMMON 0 0 Volt, 0 VA UL Listed Transformer. conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. Aux power transformer must be connected. Otherwise, RS, elevator control and weigand inputs will not function. VAC output can be used to power lights on card readers that have additional lighting for outdoor use. Weigand card reader or keypad connected to these terminals will operate Relay for its programmed strike time. Electric strikes are wired to Normally Open (N.O.) contacts; magnetic locks are wired to the Normally Closed (N.C.) contacts. Power for electric strikes or magnetic locks is not provided by the system. Use a separate UL listed power supply. Use AWG wire for runs up to 00 Ft. Use AWG wire for runs up to 00 Ft. -0 uses a keypad. - uses a card reader. The wiring is the same regardless which device is used. 00 Feet maximum between remote call station and controller. Title: DOORKING, INC., INGLEWOOD, CA 00 Remote Call Station - Telephone Interface Wire Diagram Date: / Dwg. No. M-0- Rev. E -0-W-0- Page

20 .. Controller and Two () -0 or - Remote Call Stations RS Connection Elevator Control 0 PUR Card Reader Push To Call Speaker + VDC COMMON DATA DATA 0 + VDC COMMON DATA DATA 0 0 ORG GRY LED Lights Microphone -0/ CONTROLLER VAC OUTPUT VAC OUTPUT NEG VDC INPUT POS VDC INPUT Auxiliary Terminals VAC PWR INPUT 0 PUR ORG GRY LED Lights Card Reader Push To Call Speaker Microphone -0/ Central Office phone line - touch tone, loop start. Main Terminal 0 C.O. PHN - VDC BATT INPUT + VDC BATT INPUT Relay 0 NO NC COM RELAY 0 COMMON RELAY 0 NORMALLY CLOSED RELAY 0 NORMALLY OPEN 0 RELAY NORMALLY OPEN RELAY NORMALLY CLOSED RELAY COMMON VAC PWR INPUT 0-00 BAT COM MIC 0 A switch closure across terminals & will activate relay for its programmed strike time. Battery Backup - separate batteries required for phone system and weigand terminals. Volt, 0 VA UL Listed Transformer. conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. Aux power transformer must be connected. Otherwise, RS, elevator control and weigand inputs will not function. VAC output can be used to power lights on card readers that have additional lighting for outdoor use. Weigand card reader or keypad connected to these terminals will operate Relay for its programmed strike time. Electric strikes are wired to Normally Open (N.O.) contacts; magnetic locks are wired to the Normally Closed (N.C.) contacts. Power for electric strikes or magnetic locks is not provided by the system. Use a separate UL listed power supply. Use AWG wire for runs up to 00 Ft. Use AWG wire for runs up to 00 Ft. -0 uses a keypad. - uses a card reader. The wiring is the same regardless which device is used. 00 Feet maximum between remote call station and controller. -00 Microphone combiner required when using two call stations. DOORKING, INC., INGLEWOOD, CA 00 Title: Remote Call Stations - Telephone Interface Wire Diagram Date: / Dwg. No. M-0- Rev. A Page 0-0-W-0-

21 .. Controller and 0-0 & Intercom Stations Aiphone LEM- Master E RS Connection Elevator Control Aiphone LEF Master E - CONTROLLER + VDC COMMON DATA DATA 0 VAC OUTPUT VAC OUTPUT NEG VDC INPUT POS VDC INPUT 0 Auxiliary Terminals VAC PWR INPUT 0 + uf Cap PUR ORG GRY LED Lights Card Reader Push To Call Speaker 0-0/ Central Office phone line - touch tone, loop start. A switch closure across terminals & will activate relay for its programmed strike time. Battery Backup - separate batteries required for phone system and weigand terminals. Main Terminal 0 C.O. PHN - VDC BATT INPUT + VDC BATT INPUT Relay 0 NO NC COM RELAY 0 COMMON RELAY 0 NORMALLY CLOSED RELAY 0 NORMALLY OPEN 0 VAC PWR INPUT RELAY NORMALLY OPEN RELAY NORMALLY CLOSED RELAY COMMON 0 0 Volt, 0 VA UL Listed Transformer. conductor, stranded with overall shield,, 0, or gauge is sufficient for these connections. Aux power transformer must be connected. Otherwise, RS, elevator control and weigand inputs will not function. VAC output can be used to power lights on card readers that have additional lighting for outdoor use. Weigand card reader or keypad connected to these terminals will operate Relay for its programmed strike time. Electric strikes are wired to Normally Open (N.O.) contacts; magnetic locks are wired to the Normally Closed (N.C.) contacts. Power for electric strikes or magnetic locks is not provided by the system. Use a separate UL listed power supply. Use AWG wire for runs up to 00 Ft. Use AWG wire for runs up to 00 Ft. 0-0 uses a keypad. 0- uses a card reader. The wiring is the same regardless which device is used. Aiphone Master Intercom Station supplied by others. Place a jumper wire from terminal to terminal 0 if an Aiphone LEM- master station is used. Title: DOORKING, INC., INGLEWOOD, CA 00 Remote Call Station - Intercom Interface Wire Diagram Date: / Dwg. No. M-0- Rev. E -0-W-0- Page

22 .. RS- Cable Connection BLACK WHITE BROWN GREEN SHIELD Connector on 0 Series Circuit Boards P/N -00 BOARD TERMINALS DB - PINS DB - PINS FUNCTION Transmit Data Receive Data Request to Send Clear to Send Female End Signal Ground - Shell Not Used DOORKING, INC., INGLEWOOD, CA 00 Title: Detail Wiring - 0 Series RS- Connector Date: / Dwg. No. M-0- Rev. B Page -0-W-0-

23 U.. Postal Lock Box Installation & Wiring Optional At some locations, such as gated communities, it may be necessary to provide access to the mail carrier so that they can deliver the mail. Mail carrier access can be provided by the installation of an Arrow Postal Lock into a DoorKing Postal Lock Box (p/n 0-00). This is the same lock that the Post Office uses for gang mail boxes. These locks are not available to the public. The installer or the building owner/manager will have to call the Post Office and arrange for the installation of this lock into the Postal Lock Box. 0 Postal Lock Box Installation and Wire Connections POSTAL LOCK BOX MADE BY DOORKING INGLEWOOD, CALIF.. DIA... INSTRUCTIONS. Remove the hole plug from the faceplate of the 0 lock box.. Cut the wire tie wrapped around the micro-switch.. Mount the postal lock on the studs. The pawl of the lock should depress the micro-switch.. Connect COMMON and the NORMALLY CLOSED switch contacts to main terminals and in the controller. COMMON N.C. NOTE: The Arrow Postal Lock IS NOT included with the 0 lock box. This lock is not available to the general public and must be ordered from the local Post Office. Arrow Postal Lock DOORKING, INC., INGLEWOOD, CA 00 Title: Date: 0 Postal Lock Box Installation and Wire Connections /0 Dwg. No. M-0- Rev. A -0-W-0- Page

24 Page -0-W-0-

25 SECTION PROGRAMMING IMPORTANT! Many of the advanced features available with this access control system cannot be programmed from the system keypad. These features include relay hold open time zones, security levels, anti-pass back tables, elevator control options and programming via the internet using the Internet Modem (IM) Server. If any of these features are used, the system must be programmed with the DoorKing Remote Account Manager for Windows software, VERSION..b or higher. Refer to the software help screen for more information on these features. We strongly suggest that you read these programming instructions in their entirety before beginning any programming of this access control system.. GENERAL PROGRAMMING INFORMATION The DoorKing PC Programmable Access Control System is primarily programmed by using the DoorKing Remote Account Manager for Windows software. However, the system can also be programmed from the keypad in the control cabinet. When programming from an off site location with a PC, the RING pin must be installed on the circuit board. The PC programmable access control system has three () relays on the circuit board, all of which are programmable for any function required. These relays are designated as Relay 0 (R-0), Relay (R-), and Relay (R-). If Tracker expansion boards are used with this system, it is very important that you understand the function of these relays. The wiegand input auxiliary terminals (also the Tracker board input terminals) will cause R- or R- to activate. Therefore, if Tracker expansion boards are used with this system, R- and R- are designated as Tracker board command (CMD) relays with R- controlling tracker boards through (system relays -0), and R- controlling tracker boards through (system relays -). Relay 0 is phone controlled when the has a C.O. phone line connected to it... Programming with a PC Prior to programming the system with a PC and the DoorKing Remote Account Manager for Windows Software, there is certain information that you must know and must program into the system before the computer can communicate with the system. See page to set-up the access control system for PC programming. Programming can be with a PC by modem, RS-, RS- (requires 0-0 adapters), a LAN connection (requires 0- TCP/IP kit) or via the internet using the Internet Modem Server (use of the IM Server is fee based. Visit for more information). -0-W-0- Page

26 .. Programming from the Keypad Follow the programming instructions as described in each section of this manual. The system will prompt you with short tones (beep) when programming steps have been followed correctly, and with a long tone (beeeeeep) when the programming step is ended. It is highly recommended that you complete the user listing in the appendix prior to starting any programming from the keypad. This listing will provide you with the information needed to complete the manual programming sequence. This symbol _ in the programming steps indicates numbers that you will need to enter, one number per symbol. When programming from the keypad, after each programming step is performed correctly, a short tone (beep) will be heard. When the programming session is ended, a long tone (beeeeeep) will be heard. NOTE: Relay hold open time zones, security levels, anti-pass back IN / OUT tables, anti-pass back re-sync schedules, holiday schedules and elevator control functions cannot be programmed from the system keypad. These functions can only be programmed from a PC using the Remote Account Manager Software... System Memory Beginning in January, 00, the access control system is available with a 00 or 000 memory (APB) chips installed in the system. The information below is to assist you with programming older systems or when there is a need to change the memory chips to match a chip set on another system already installed. Prior to starting the programming of the PC programmable access control system, you must know the memory capacity and type of the EEPROM chips that are installed in the unit. This can be determined by inspecting the small chip that has a tag listing the memory size on it and will be labeled APB if anti-pass back is enabled. The memory size determines the number of residents, vendors, four-digit entry codes and device codes that can be stored in the system. APB indicates that the chip set has anti-pass back capability. The table shows the valid numbers available with each memory level. Standard Part Number APB System Memory User Name Capacity Entry Code Capacity Device Code Capacity Page -0-W-0-

27 U0U UU and U*U (beep) U#U TOGETHER U*U (beep) (beep).. PROGRAMMING WITH A PC Prior to programming the PC Programmable Access Control System with the DoorKing Remote Account Manager for Windows software and the user supplied PC, the system must have the MASTER CODE programmed into it. The master code cannot be set with the PC and must be programmed from the system keypad. NOTE: The programming steps in this section (.. through..) can only be programmed from the system keypad. There is no programming sequence in the Remote Account Manager Software for these functions... Master Code This programming step sets the system MASTER CODE. The master code is the four-digit number required to gain access to the system memory. You need to know the master code prior to programming the system with the PC, or to perform any of the programming functions on the following pages. Factory setting =. Open the cabinet of the telephone entry system and turn the master code switch (the small slide switch) to the on position.. Enter a four-digit master code then press U*U. Turn the master code switch off and close the cabinet... Single or Multiple Systems This program sequence sets the access control system to operate as a single unit on the phone line, or to share the phone line with other units. If multiple systems are sharing the same phone line, then each one must be set as a "multiple system" and each must have a unique master code. Factory setting = Single System.. Press U*U. Enter U0U. Press U0U then enter the four-digit MASTER CODE (beep). for a single system or UU for multiple systems. to end this programming step (beeeeeep)... Programming Resident Elevator Button Relay Time When elevator control is in use, an access device such as a card reader must be installed in the elevator car to allow residents access to the floors in the building. The time interval that the button(s) is live after the resident activates the access device is dependant on the revision level of the access controller circuit board, not the elevator control board. The relay time interval for circuit boards with revision level A-C is set at seconds. The time interval can be programmed from seconds on boards with revision level D and higher. Factory setting = 00. Press * and then enter the four digit master code (beep).. Enter the relay time in seconds _ (00-) then press * (beep).. Press 0 # together to end this programming sequence (beeeeeep). -0-W-0- Page

28 U.. Open Tone On or Off The following programming sequence turns the open tone (when the relays activate) either On or Off. This feature is available on Rev J boards or higher. Factory setting = (tone on). Press * and then enter the four digit master code (beep).. Enter for yes (tone will sound) or 0 for no (tone will not sound) then press * (beep).. Press 0 # together to end this programming sequence (beeeeeep)... Elevator Control Function The elevator control feature authorizes floor access to the Floor Level identified in the Resident Screen in the software program AND to the floor(s) level identified in the Security Level screen. If this feature is turned off, access will be granted only the floor identified in the user s security level. This feature is available on Rev J boards or higher.. Press * and then enter the four digit master code (beep).. Enter for yes (access is authorized to both the floor identified in the resident screen and to the floor(s) identified in the user s security level) or 0 for no (access is authorized only to the floor(s) identified in the security level screen) then press * (beep).. Press 0 # together to end this programming sequence (beeeeeep)... RS- Speed Setting The following programming sequence sets an optional faster RS- speed. This feature is available on Rev L boards or higher and the Remote Account Manager Software, Version., must be used. Factory setting = 0 (00 baud rate). Press * and then enter the four digit master code (beep).. Enter 0 for 00 baud rate or for 00 baud rate then press * (beep).. Press 0 # together to end this programming sequence (beeeeeep). STOP!! If the access control system is to be programmed from a PC, no other programming is required at the system itself. Refer to the Remote Account Manager for Windows Software help screens for additional programming information. Continue with the remaining sections in this chapter if the access control system will be programmed by any other method. If the factory setting matches your need, there is no reason to reprogram that section. Remember that relay hold open time zones, security levels, and elevator control functions can only be programmed from the Remote Account Manager Software. If any of these features are being used, do not proceed with any other programming steps in this manual. Page -0-W-0-

29 U0U UU and U*U to U#U TOGETHER U*U to U*U to (beep).. GENERAL PROGRAMMING Proceed with the programming steps on the following pages only if PC programming will not be used... Relay Strike Time These steps will program relay strike times. Strike times can be programmed from / second (enter 00 in step ) up to seconds by entering the desired time in seconds. If Tracker expansion boards are going to be used with this system, set Relay strike time to 00 for Tracker boards -. If more than Tracker boards are being used, set Relay strike time to 00 (for Tracker boards -). Factory setting for relay strike times are: Relay 0 = 0, Relay = 0, Relay = 0.. Press U*U enter the four-digit MASTER CODE (beep).. Press 0U set relay 0 or, UU set relay, or UU set relay strike time.. Enter the two-digit strike time (00-) then press U*U. Repeat steps and to set other relay strike times.. Press U0U to end this programming step (beeeeeep)... Talk Time The talk time set here does not affect the telephone numbers that are programmed under directory codes 0, 00, 000, 0000 (input A) and, 0, 00, 000 (input Z). The talk time for these two directory codes are factory set to the maximum. Phone numbers programmed under these directory codes should be reserved for management or emergency phone numbers that generally require longer conversations. This programming sequence can be used to set the maximum time allowed for conversation when the entry system places a call to a phone number programmed under directory code, 0, 00 or 000 (inputs A-Z together). The talk time can be set from second up to seconds ( minutes, seconds) and is entered as a three-digit number. For example, to set a talk time of 0 seconds, enter 00 in step. Factory setting for talk time = 0 seconds. NOTE: This programming step is only used when a DKS Remote Call Station is connected to the system.. Press * 0 and enter the four digit MASTER CODE (beep).. Enter three digits for talk time (seconds) _ (00-) then press * (beep).. Press 0 # TOGETHER to end this programming step (beeeeeep). -0-W-0- Page

30 U0U UU and U*U to U#U TOGETHER UU U0U and U#U TOGETHER U*U to U*U to (beep). (beep)... Tone Open Numbers These steps will program the tone open numbers for the relays. You will need to enter a four-digit number (see chart below) to set the relay functions. If a function is not desired, enter # in place of a number. For example, if you want the relay to have a momentary activation function only, and you want the relay to activate when the number is pressed on a touch-tone phone after calling the system, enter # # # in step. Do not duplicate tone open numbers, i.e., don t set relay 0, relay and tone-open numbers all to. If Tracker expansion boards are connected to the system, there is no need to set a momentary open tone open number for the tracker control relay(s). However, you may want to set HOLD and DEACTIVATE tone numbers, which will allow management to have a function to automatically unlock all doors/gates controlled by a Tracker board (refer to..). Factory setting is: Relay =, Relay =.. Press U*U. Press U0U enter the four-digit MASTER CODE (beep). set relay 0 or UU set relay or UU. Enter the four-digit tone open number code then press U*U set relay tone numbers.. Repeat steps and to set the other relay tone open numbers.. Press U0U to end this programming step (beeeeeep). NUMBER FUNCTION st Digit Momentary activation. Relay will activate for the programmed strike time (..). nd Digit Relay hold. Relay will activate and remain activated until commanded to release. rd Digit Relay release. Deactivates the relay hold command. th Digit Relay hold -hour. Relay will activate for -hour and then will automatically deactivate itself... Input Switch This programming sequence sets what relay(s) will activate when the input (postal) switch input is activated on the access control system. The system can be programmed so that only one relay will activate, or any combination of relays will activate. To cause a relay to activate, enter a in it's respective character slot, or enter a zero to not activate the relay. Any combination of 's or 0's is permissible. For example, entering 00 in step will cause only relay to activate. Entering 0 will cause relay and relay to activate. Entering will cause all three relays to activate. Factory setting = 00 (Only relay will activate). Press U*U enter the four-digit MASTER CODE (beep).. Enter the three-digit ('s or 0's only) postal relay code _ then press U*U. Press U0U to end this programming step (beeeeeep). Page 0-0-W-0-

31 .. Touch-tone / Rotary-dial This programming sequence will set the remote call station to dial out in either a touch-tone or rotary format. Generally, this will be set for touch-tone. Factory setting = touch-tone. NOTE: This programming step is only used when a DKS Remote Call Station is connected to the system.. Press * 0 and enter the four digit MASTER CODE (beep).. Enter 0 * (beep) for touch-tone or enter * (beep) for rotary.. Press 0 # TOGETHER to end this programming step (beeeeeep). -0-W-0- Page

32 UU U0U and then to then to (beep).. PROGRAMMING PHONE NUMBER NOTE: These programming steps are only used when a DKS -0 or - Remote Call Station is connected to the system... Programming the Directory Code Length This programming sequence sets the directory code length to - - or digits. Factory setting is three () digits. CAUTION: This programming sequence will delete all directory codes that have been previously programmed into the system.. Press U*U enter the four-digit MASTER CODE (beep).. Enter the desired directory code length _ (,, or ) then press U*U. Enter U0U U*U cancel this command or enter UU U*U confirm this command. A long tone (beeeeeep) will sound when the programming is complete... Programming -digit Phone Number In this programming sequence, the directory code and -digit phone number will be programmed into the system. Be sure you have programmed the directory code length that you desire as described in... Changing the directory code length after programming the telephone number will erase all the numbers and directory codes that have been programmed. To program a phone number that will be referenced to an area code (long distance calls and 0 digit calling), follow the instructions under.. and... NOTE: If this system is being used in an area that requires 0 or digit dialing, proceed to..,.. and.. to program the number of area codes, area code and phone number.. Press * 0 and enter the four-digit MASTER CODE (beep).. Enter the directory code (,, or digits depending on what was programmed in..) then press * (beep),. Enter the seven-digit phone number _ then press * (beep). If the number that you are entering in this step is less than seven-digits, enter # in the empty spaces. For example, if the system is connected to a PBX that requires four-digit extension numbers and you want to enter extension, you would enter this number as #### then press * (beep).. Press 0 # TOGETHER to end this programming step (beeeeeep). NOTE: Only the following Directory Codes may be used: 0, 00, 000, 0000, OR, 0, 00, 000. Page -0-W-0-

Owner s Manual PC Programmable Multi-Door Access Controller

Owner s Manual PC Programmable Multi-Door Access Controller Owner s Manual PC Programmable Multi-Door Access Controller DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 00 U.S.A. Phone: 0--00 Fax: 0-- www.doorking.com P/N -0 REV P, / Copyright 00 DoorKing,

More information

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems Owner s Manual 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-45-0023 Fax: 310-41-158

More information

Owner s Manual PC Programmable Multi-Door Access Controller

Owner s Manual PC Programmable Multi-Door Access Controller Owner s Manual 1818 PC Programmable Multi-Door Access Controller DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1818-065

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

Owner s Manual. 1803, 1808, 1810 Telephone Entry Systems

Owner s Manual. 1803, 1808, 1810 Telephone Entry Systems Owner s Manual 1803, 1808, 1810 Telephone Entry Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1800-060 REV M, 8/08

More information

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems Owner s Manual 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586

More information

Owner s Manual. Model 1812 Telephone Intercom Systems

Owner s Manual. Model 1812 Telephone Intercom Systems Owner s Manual Model 1812 Telephone Intercom Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1812-065 REV M, 3/07

More information

EPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed

EPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed Installation/Owner s Manual Use this manual for circuit board 86- Revision L or higher. Model 8 & 8EPD Telephone Entry System 8-65-D--4 Control a main entry point plus an additional entry point. 8. 3 ATING

More information

EPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed

EPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed Installation/Owner s Manual Use this manual for circuit board 86- Revision P or higher. Model 8 & 8EPD Telephone Entry System 8-65-N-- Control a main entry point plus an additional entry point. 8. 3 ATING

More information

Owner s Manual. Model 1808 and 1810 Access Plus Systems PC Programmable Telephone Entry / Access Control System

Owner s Manual. Model 1808 and 1810 Access Plus Systems PC Programmable Telephone Entry / Access Control System Owner s Manual Model 808 and 80 Access Plus Systems PC Programmable Telephone Entry / Access Control System DoorKing, Inc. 0 Glasgow Avenue Inglewood, California 900 U.S.A. Phone: 0--00 Fax: 0--8 www.doorking.com

More information

EPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed

EPD. Installation/Owner s Manual. Model 1802 & 1802EPD Telephone Entry System. Surface Mount Flush Mount. UL Listed Installation/Owner s Manual Use this manual for circuit board 86- Revision O or higher. Model 8 & 8EPD Telephone Entry System 8-65-G-3-5 Control a main entry point plus an additional entry point. 8. 3

More information

Owner s Manual Telephone Intercom System with Call Down

Owner s Manual Telephone Intercom System with Call Down Owner s Manual 1820 Telephone Intercom System with Call Down DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1820-065 REV

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model 1812 Plus Residential Telephone Intercom/Access Control System Use this manual for circuit board 1971-1 Revision U or higher. Control a main door and gate. 4 2 3 5 6 1

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model 1812 Classic Residential Telephone Intercom/Access Control System Use this manual for circuit board 1871-1 Revision S or higher. 1812-65-B-1-17 Control a main door and

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Use this manual for circuit board 88- Revision Y or higher. 88 PC Programmable Multi-Door Access Controller 88-65-K-5-7 6, and -Bit Wiegand Compatible Date Installed: Installer/Company

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Use this manual for circuit board 88- Revision U or higher. DoorKing recommends replacing the Standard Key Lock with the Random Key Lock that is included. See back cover for

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model 1812 Classic Residential Telephone Intercom/Access Control System Use this manual for circuit board 1871-1 Revision S or higher. 1812-65-U-12-13 Control a main door and

More information

Installation/Owner s Manual 1838 Access Plus

Installation/Owner s Manual 1838 Access Plus Installation/Owner s Manual Access Plus PC Programmable Access Control System Use this manual for circuit board - Revision U or higher. --G-- Control a main door, gate and six additional RS- entry points.

More information

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because

More information

VOICE and/or DATA CELLULAR SYSTEM

VOICE and/or DATA CELLULAR SYSTEM ... VOICE and/or DATA CELLULAR SYSTEM The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE network where available. The system provides voice

More information

VOICE and/or DATA CELLULAR SYSTEM

VOICE and/or DATA CELLULAR SYSTEM ... VOICE and/or DATA CELLULAR SYSTEM This cellular device cannot be used for 9 calls. The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model Access Plus PC Programmable Residential Telephone Intercom/Access Control System Use this manual for circuit board - Revision U or higher. --B-- Control a main door, gate

More information

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without

More information

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300 Model CMX-300 Technical Practice October 2015 Issue 6 MODEL CMX-300 Service Observing System 1. GENERAL 1.1 The Dees CMX-300, installed with the Dees CM-30, increases the number of stations to be observed

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

Installation/Owner s Manual

Installation/Owner s Manual Installation/Owner s Manual Model Access Plus PC Programmable Residential Telephone Intercom/Access Control System Use this manual for circuit board 9- Revision M or higher. --S-- Control a main door,

More information

Model 1834 PC Programmable Telephone Entry System

Model 1834 PC Programmable Telephone Entry System Enter on Open Display and Tone. WXY SP Enter on Open Display and Tone. Installation/Owner s Manual Model 1834 PC Programmable Telephone Entry System Use this manual for: Surface/Flush mount circuit board

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

AccessPlus VOICE and/or DATA CELLULAR SYSTEM

AccessPlus VOICE and/or DATA CELLULAR SYSTEM AccessPlus VOICE and/or CELLULAR SYSTEM This cellular device cannot be used for calls. Destructive Attack: Line Security: Endurance: Standby Power: Level I Level I Level IV Level I - The AccessPlus Voice/Data

More information

Installation/Owner s Manual

Installation/Owner s Manual ...... Enter on Tone. Installation/Owner s Manual PC Programmable Telephone Entry and ccess Control Systems Wall Mount Flush Mount, and -Bit Wiegand Compatible Surface Mount 8 For 8 circuit board: Wall

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

AccessPlus VOICE and/or DATA CELLULAR SYSTEM

AccessPlus VOICE and/or DATA CELLULAR SYSTEM AccessPlus VOICE and/or CELLULAR SYSTEM This cellular device cannot be used for calls. Destructive Attack: Line Security: Endurance: Standby : Level I Level I Level IV Level I - The AccessPlus Voice/Data

More information

Model 1834 PC Programmable Telephone Entry System

Model 1834 PC Programmable Telephone Entry System Enter on Open Display and Tone. WXY SP Enter on Open Display and Tone. Installation/Owner s Manual Model 1834 PC Programmable Telephone Entry System Use this manual for: Surface/Flush mount circuit board

More information

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could

More information

Open Applications Interface (OAI) Installation and Setup

Open Applications Interface (OAI) Installation and Setup Open Applications Interface (OAI) Installation and Setup Link Wireless Telephone System Link 3000 MCU Part Number: 72-0059-07 Issue A NOTICE SpectraLink Corporation has prepared this document for use by

More information

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code: INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation

More information

2GI. Touch Screen Wireless Keypad

2GI. Touch Screen Wireless Keypad 2GI Touch Screen Wireless Keypad For Remote Control of the 2GIG Security System INSTALL INSTRUCTIONS This document describes the basic installation information for the 2GIG TS1 and the steps necessary

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

DIAMOND ELITE SERIES USERS GUIDE

DIAMOND ELITE SERIES USERS GUIDE DIAMOND ELITE SERIES USERS GUIDE COVERS MODELS L2-E L2S-E L2-5E L2S-5E L2-10E L2S-10E DIAMOND ELITE SERIES TELEPHONE DIAGRAM Hold Key Line 1 Line 2 Conference Key Handset Holder Ringer Volume Control Data

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control January 2013 PRICE SCHEDULE A 2.0 Section A4 Date Page Comment 1 1 13 All January, 2013 Price Schedule update. 2 13 13 6 Removed 1812 092 from 1812 145 kit. Added 1812 092 to 1812 147 kit. 2 13 13 9 P/N

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer

TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer TE7210/LCD AUTODIALER Integrated Full-Page Directory/ Autodialer INTSTALLATION & PROGRAMMING MANUAL Alpha Communiations www.alphacommunications.com 42 Central Drive Farmingdale NY 11735 Phone: 631-777-5500

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

APPLICATION PROCEDURE HOUSING INSTALLATION AND EQUIPMENT LOCATION

APPLICATION PROCEDURE HOUSING INSTALLATION AND EQUIPMENT LOCATION NH208TVU Amplifier and Power Supply Installation and Use Instructions Used with the HT2006 Series Inside Handset Intercom Stations and 1 or more Door Stations APPLICATION The NH208TVU series intercom system

More information

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning! PRODUCT DESCRIPTI The DL is a dialer module, which contains a Digital Alarm Communicator Transmitter (DACT). The dialer sends alarm, supervisory, and trouble information to a compatible Digital Alarm Communicator

More information

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

Trademark Generation II Series Intercom System Installation and Operation Reference Guide Trademark Generation II Series Intercom System Installation and Operation Reference Guide www.escoservices.com Components: Desktop Controller, Digital Interface Box, -Speaker I/O Card, 9VDC Power Supply

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MicroComm DXI. Intent & Scope This document describes the installation procedure for the IMS-30 Intercom Master Station and the MAI-420 or MAI-20 Master Audio Interface. The earliest

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module) Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL

More information

Telephone Entry System

Telephone Entry System Telephone Entry System TE-200-II C-0902 (PCB w/ mounting plate) 234 FISCHER AVENUE COSTA MESA, CA 92626 (714) 424-6500 (800) 840-0288 (714) 424-6510 FAX HTTP://WWW.CHANNELVISION.COM E-MAIL: SALES@CHANNELVISION.COM

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

WS must be used in a temperature controlled place. It is compliant to ETS Class T

WS must be used in a temperature controlled place. It is compliant to ETS Class T Important Information about the Sagemcom F@ST 2705 WS: Operational working: F@ST2705 WS must be used in a temperature controlled place. It is compliant to ETS 300 019-1-3 Class T 3.2 standard: 1. Temperature

More information

1812 Series Telephone Intercom

1812 Series Telephone Intercom 1812 Series Residential Systems Residential Systems: For Single Family Homes and Estates Access Control Solutions Telephone Entry + Access Control Computer Programmable for Larger Residences and Estates

More information

Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage Maximum Security

Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage Maximum Security STANDARD TELEPHONE ENTRY Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage Maximum Security Basic Telephone Entry Systems Mounting

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

DESIGN GUIDE FOR INFINITY SYSTEMS

DESIGN GUIDE FOR INFINITY SYSTEMS Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...

More information

0 # ES&P VENTURES CORP. Engineering Services & Products

0 # ES&P VENTURES CORP. Engineering Services & Products 1 4 7 * 2 3 5 6 8 9 0 # 1 4 7 * 2 3 5 6 8 9 0 # ES&P VENTURES CORP. Engineering Services & Products SYSTEM FEATURES Capacity for up to 1000 Tenants. Simple Upgrade from Autodialer to No Telephone Line

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with

More information

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1. WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone

More information

INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE LP MODEL OVATION SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM Doc. 6001073 Rev B Page 2 of 31 Doc. 6001073 Rev B IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing

More information

Telephone Line Monitor USER GUIDE

Telephone Line Monitor USER GUIDE Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Installation Instructions 4291 and 4292 Keypads

Installation Instructions 4291 and 4292 Keypads Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

INSOMNIAC CIA K-500 Keypad Installation Manual P/N CIA Revision 1.1 Date Code:

INSOMNIAC CIA K-500 Keypad Installation Manual P/N CIA Revision 1.1 Date Code: INSOMNIAC CIA K-500 Keypad Installation Manual P/N CIA-575-001 Revision 1.1 Date Code: 7-1-2018 Table of Contents SPECIFICATIONS:... 3 INSTALLATION... 4 General:... 4 Physical Installation and Mounting...

More information

Doc Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS

Doc Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS Doc.. 6001145 Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS TABLE OF CONTENTS IMPORTANT NOTICES... 3 INSTALLATION TIPS... 3 PART 1 PULLING CABLES... 4 A. WIRE INFORMATION... 4 B.

More information

G.SHDSL NTU with Fixed Serial Interfaces

G.SHDSL NTU with Fixed Serial Interfaces DECEMBER 2006 ME231A ME232A ME233A G.SHDSL NTU with Fixed Serial Interfaces CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX SUPPORT FREE technical support,

More information

SERVICE MANUAL MODEL SSW-521-D2-ADA

SERVICE MANUAL MODEL SSW-521-D2-ADA SSW-521-D2-ADA-SPK1.07UNVLr3-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-D2-ADA STAINLESS STEEL HANDS FREE WALL TELEPHONE WITH OPTIONAL ADA FEATURE AND OPTIONAL SECOND-NUMBER AUTO-DIAL FEATURE EQUIPPED

More information

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA WPP-531-X-ADA OR SSP-511-X-ADA-SPK1.07-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA HANDS FREE EMERGENCY WEATHERPROOF TELEPHONE OR MODEL SSP-511- X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED

More information

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE NO PHONE BILL INTERFACE Doc - 6001003 Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE IMPORTANT NOTICES The "No Phone Bill Interface" (hereafter referred to as the "NPBI") contains static sensitive parts. To

More information

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE OVATION SYSTEMS

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE OVATION SYSTEMS Doc.. 6001072 Rev B INSTALLATION INSTRUCTIONS FOR THE "S" AND "V" MODEL OVATION SYSTEMS IMPORTANT NOTICE Make sure you know the local telephone tariff arrangements before installing this system. In some

More information

Microphone Mux Module Installation Instructions

Microphone Mux Module Installation Instructions 4100-1274 Microphone Mux Module Installation Instructions Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation manual. These instructions must be followed

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

and Network Interface Modules Installation Instructions

and Network Interface Modules Installation Instructions 4010-9817 and 4010-9821 Network Interface Modules Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the

More information

Q WIEGAND EXPANSION MODULE

Q WIEGAND EXPANSION MODULE Q WIEGAND EXPANSION MODULE INSTALLATION MANUAL To prevent possible SERIOUS INJURY or DEATH: READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. The user is strongly recommended to conduct a product

More information

LA600WH WIRED / WIRELESS DOOR CHIME

LA600WH WIRED / WIRELESS DOOR CHIME LA600WH WIRED / WIRELESS DOOR CHIME To register this product, visit: www.nutone.com THIS PACKAGE INCLUDES: Wired / Wireless Door Chime with MP3 upload capability Decorative White Chime Cover USB Cable

More information

Section A3 PC Programmable Telephone Entry & Access Control For current pricing, please use our Dealer Portal. Date Page Comment

Section A3 PC Programmable Telephone Entry & Access Control For current pricing, please use our Dealer Portal. Date Page Comment April 2015 Section A3 For current pricing, please use our Dealer Portal. http://doorking.com/dealer-distributor Date Page Comment 4-1-15 All April, 2015 reference guide update. Specifications subject to

More information

January 2013 PRICE SCHEDULE A 2.0 PC Programmable Telephone Entry & Access Control. PC Programmable Telephone Entry & Access Control

January 2013 PRICE SCHEDULE A 2.0 PC Programmable Telephone Entry & Access Control. PC Programmable Telephone Entry & Access Control January 2013 PRICE SCHEDULE A 2.0 Section A3 Date Page Comment 10-1-13 All October, 2013 Price Schedule update. 1-25-13 18 Added part numbers to TagMaster products. 2-13-13 9 Removed wireless wiegand devices

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE WPP(HOB)-531-D2 OR SSP-511-D2-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE OR MODEL SSP-511-D2 STAINLESS STEEL PANEL

More information

Installation and Programming Instructions for the PhoneAire. Model

Installation and Programming Instructions for the PhoneAire. Model Installation and Programming Instructions for the PhoneAire Model 16-1050 1 FCC REQUIREMENTS 1. This equipment complies with Part 68 of the Federal Communications Commission Rules. On the inside panel

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MicroComm DXI MAI-425 Master Audio Interface. Intent & Scope This document describes the installation procedure for the MAI-425 Master Audio Interface. The earliest version of

More information

Installation Manual & User Instructions. MultiCom 500

Installation Manual & User Instructions. MultiCom 500 Installation Manual & User Instructions For MultiCom 500 Multi resident GSM Intercom System Contents Section Description Page 1 Introduction 3 2 Getting started 3 3 SIM card 3 4 Wiring 4 5 Keypad / onscreen

More information

SAT SELECT ENTRY SYSTEMS. User / Installer Guide. Dec 08 SAT3 SAT3/D

SAT SELECT ENTRY SYSTEMS. User / Installer Guide. Dec 08 SAT3 SAT3/D SAT3 USER / INSTALLER GUIDE SAT 3 SELECT ENTRY SYSTEMS User / Installer Guide Dec 08 SAT3 SAT3/D SAT3 USER / INSTALLER GUIDE V1.X S elf Identifying A utomatic T elephone 3 & 3/D Select Engineered Systems,

More information

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0 SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0 Fax: (514) 683-0068 Rev : 3.0 www.novyc.com Page 1 of 11 WARNING The ROS Scroll Display System must be installed as per Novyc International's

More information

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

4100/4120-Series Class A / Class B Zone Modules Installation Instructions 4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box

More information

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED CE PRODUIT DOIT ÊTRE

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

January 2013 PRICE SCHEDULE A 2.0. PC Programmable Telephone Entry & Access Control

January 2013 PRICE SCHEDULE A 2.0. PC Programmable Telephone Entry & Access Control January 2013 PRICE SCHEDULE A 2.0 Section A3 Date Page Comment 10 1 13 All October, 2013 Price Schedule update. 1 25 13 18 Added part numbers to TagMaster products. 2 13 13 9 Removed wireless wiegand devices

More information

TELEPHONE ENTRY / ACCESS CONTROL SYSTEMS

TELEPHONE ENTRY / ACCESS CONTROL SYSTEMS Internet Programmable Regional DKS PLUG & PLAY CONNECTION OPTIONS Sales Manager Locations TELEPHONE ENTRY/ ACCESS CONTROL SYSTEMS DKS offers easy ways to connect fast using DKS connection services. With

More information

Manual No: Revision: F. Relay Output Modules. Installation Guide

Manual No: Revision: F. Relay Output Modules. Installation Guide Manual No: 576013-614 Revision: F Relay Output Modules Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988 www.gkinc.com support@gkinc.com Technical Practice Contents Section 1 General Description Section 2 Applications Section 3 Installation Section 4 Circuit Description Section 5 Specifications Section 6

More information