WRI400 WIRELESS READER INTERFACE
|
|
- Angelina Gibson
- 6 years ago
- Views:
Transcription
1 WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1
2 Training Overview WRI400 Description Information Installation Comparison to Legacy WRI SUS/HHD Ah-Ha s
3 WRI400 installed in Systems; AD Series Wireless Technology and access features to openings Door Opening Elevators Gate March 12 Technical Services Engineering Support 3
4 WRI400 Description The Schlage WRI400 is an ON-LINE wireless interface module with AD- Series technology The WRI400 can configure any opening with equivalent AD400 features Using industry portal devices; credential readers, strikes, DPS, RTX and RTE switches The WRI400 Wirelessly Interfaces readers and access control devices to a PIM400 Link and assign the WRI400 like a AD400 for AD-Series features Assign as a Legacy (PIM-485 and WRI) for Legacy features (See later page) The WRI400 is for major Openings, decorative Openings, dual door Openings, Openings using magnetic-lock, electric strikes The WRI400 will also be in an Elevator and Gate Access kit, see user manual The SUS/HHD connects with the WRI400 USB for firmware updates, to view or edit Lock Properties like an AD400 The WRI400 uses the same main Printed Circuit board and enclosure as the CT5000. They can be re-classed with Firmware (Remember the LID Label) March 12 Technical Services Engineering Support 4
5 WRI400 Description The WRI400 can be used with up to two (2) credential readers that have Wiegand or Clock and Data outputs (wave58171) Left-side/right-side readers, ADA reader and mullion reader, Gates, and Elevators NOTE ; Both readers are the same Opening, they have the same identical access rights WRI400 Supports three optional status inputs:, Request to Enter (RTE) Request to Exit (RTX) Door Position Switch (DSP) Reader 1 Tamper and Reader 2 Tamper are reported by the WRI400; but not indentified by Access Control Panels yet - Will call Tamper1/2 Lock Clutch Engaged or Dead bolt or Latch bolt Engaged Supports TWO (2) Form C, dry contact relays outputs, Strike - Electric Strike, magnetic lock, Auxiliary ADA door opener (Automatic operator) CONTROLED BY ACCESS CONTROL PANEL
6 WRI400 Description The Alarm relay Is not used by the WRI400 firmware The WRI400 has no Buzz-in reporting feature Buzz-in switches can be wired across the STRIKE relay output The WRI400 is a powered device and must have +12 or +24 volt power, No AA battery operation for the WRI400, relay control requires more power than batteries No coin cell is needed or used by the WRI400, (Like the AD400) wave58154 Coin Cell batteries are not shipped in the WRI400 The PCB silk screen says COIN CELL NOT NEEDED IF RADIO BOARD PRESENT The WRI400 needs a UL294 Listed Class 2 power supply, not included. (example: Schlage models PS902, PS904, and PS906) Note: The WRI400 will not power the readers wave57830 When sharing the power supply you must get the polarities correct, and select a supply which is compatible with the reader and the WRI400. The WRI400 requires 12volt 500ma; and READERS are typically 12VDC to 5VDC 200 ma each
7 Assigning BrightBlue Templates BrightBlue will be updated late this fall to include WRI400 assignment templates. Below Work Around With BrightBlue as it is now; AD-Series, Assign the WRI400 as an AD400 Request to Enter (RTE) Request to Exit (RTX) Door Position Switch (DSP) NO AUX function, (NO ALRAM function) Assign as a Legacy, Assign a PIM400 using a BB Legacy Template WRI400 as a Legacy WRI This PIM400 can now only link to a device on a Legacy Template, it can not be shared with AD400 locks) LINK the PIM400 and the WRI400 and they now report like a Legacy WRI with AUX operations
8 WRI400 in a System March 12 Technical Services Engineering Support 8
9 WRI400 User Interface Green LEDs RED Buttons Brown Relay Status LEDs Blue Jumper March 12 Technical Services Engineering Support 9
10 WRI400 Information User guides - P Data Sheets Technical Bulletins Firmware down loads Knowledge Center for technical questions RADAR Reporting Siebel SR reports with actions into Test Track Pro March 12 Technical Services Engineering Support 10
11 Agency UL ratings Suitable for outdoor use, ambient temperature range -35C to +66C (-31F to +151F) and weather tight NEMA enclosure when using a NEMA gland The WRI400 is listed under UL294 as an access control system subassembly UL listed panic hardware must be used to allow emergency exit from the protected area The WRI400 has not been evaluated to UL325 or UL508, UL325/508 are automation standards March 12 UL 325 is a safety standard for door, drapery, gate, louver, and window operators and systems. Specifically, it applies to electric operators for doors, draperies, gates, louvers, windows and other opening and closing appliances rated 600 volts or less. UL 508 is a standard for Industrial Control Equipment. Technical Services Engineering Support 11
12 PIM400 and WRI400 Installation Location WRI400 mounting location is similar to the AD Series for RF communication to the PIM400 Secured side of the access portal The maximum RF distance indoors between a PIM400 and a WRI400 is 200 feet (61 meters) Same floor in a building normal construction materials The maximum distance for a line-of-sight installation is 1000 feet (305 meters) March 12 Technical Services Engineering Support 12
13 PIM400 and WRI400 Installation Location WRI400 can use the ANT400 antenna kits for increased RF communication range Use of high-gain antenna (ANT400-REM I/O +6DB) will improve range The antenna KIT includes a 15 foot cable (4.5 meters) Don t exceed this cable length Do not locate the WRI400 and remote antenna, or the PIM400 (and its remote antenna, if used) on separate floors within a building (However having both antennas on the same floor is OK) Mounting a WRI400 is just like a PIM400 Vertically with the radio board at the top of the enclosure If on a metallic surface, stand the WRI400 off 1 inch (25 mm) from the metal 13
14 WRI400 Installation Wiring Portal Inputs; Status Monitors RTE, RTX, and DPS expect dry contact inputs switched to Ground when the switch is closed and the signal is ACTIVE Reader 1 Tamper and Reader 2 Tamper expect dry contact switches tied to Ground when the switch is closed, OR a signal level input for 5V logic Don t exceed 5V it will cause damage Connect the shield of the portal input cables to the appropriate WRI400 GND terminal see User Guide To ensure proper integration with the ACP, the input logic may be changed from the default condition using the Schlage Utility Software (SUS) on the HHD 14
15 Credential Readers Inputs READER inputs; Auto-Detect Wiegand (D1/D0) Magnetic (Clock and Data) -Two separate credential reader interface headers, J17 & J18 -Reader input ports are designed for 5V logic (Typical) - Don t exceed 5VDC -The most extensive testing was with; -Essex Electronics model KTP-162 (Keypad) -Schlage SMR-5 & SMR-20 -Mercury Security MR-5 & MR-20 (Mag Stripe) - Schlage SXF-1050 & SXF-150 (Prox) - SXF-1100, SXF-1500, SXF-2100, SXF-2110 (Multi-Tech) March 12 Technical Services Engineering Support 15
16 WRI400 control of the READER - Beeper, Green LED, RED LED! The WRI400 does not provide power to the readers! The WRI400 will use the reader beeper with a FDR. -Please consult with the reader s manufacturer for reader configuration, readers typically beep with a card present. - Reader beeper and LED controls are configured by the reader factory per order. Configuration can sometimes be changed in the field using a "Configuration Card" from the reader manufacturer -Example: If the reader is ordered with RED LED always ON (Indicating power at the READER), the WRI400 can not turn the RED LED off
17 Portal Outputs, to the Door Strike & AUX Outputs are Form C relays; C, NO, NC Transient suppression per the Load Ratings are in the User Guide, Strike - 24VDC, 240vac AUX 24VDC, 120vac March 12 Technical Services Engineering Support 17
18 RF PCB; The WRI400 uses the same COM400 board as the PIM400 - It has a MCX/SMB jack for the optional antenna kit The MCX Jack is the only difference between the AD400 to WRI400/PIM400 COM400 - COM400 FW 2.2a and 2.2d are compatible everywhere 18
19 LEGACY PRODUCTS WRI400 AD SERIES Reader Interface Times Two Two Readers, same Door file Two Readers same door file Two readers Wired in Parallel CLK/D1 DATA/D0 12VDC+ GND GRN_LED RED_LED n/a READER_TAMPER Two Reader Connectors J17 & J18 CLK/D1 DATA/D0 n/a Reader powered separately GND GRN_LED RED_LED BEEPER (Two) READER_TAMPER (subject to ACP interpretation) March 12 Technical Services Engineering Support 19
20 LEGACY PRODUCTS CREDENTIALS PIN only Credential + PIN Prox/Mag Cards Smart Cards not supported WRI400 AD SERIES ONLY with Card Emulation using a 26-bit keypad (Special order READER Configuration) ONLY if the keypad is 8-bit format (typical READER/Keypad) Prox/Mag Cards (AD Series) Smart Cards (AD Series) Power, Supply must be UL 294 Listed 12 ma + READER Legacy WRI has a reader power jack 12 or 24 Volt ma No coin cell battery is needed/used No READER Power output - If using a 24 volt power supply, Do not over voltage the reader. Check the reader voltage requirements March 12 Technical Services Engineering Support 20
21 LEGACY PRODUCTS WRI400 AD SERIES Legacy PIM PIM400 - AD-Series (TD2 & 485) 200' Horizontally through walls 200 Horizontally through walls 1000' line-of-sight 1000' line-of-sight ANT-REM Gate Elevator ANT 400 (Ceiling, HALL & I/O+6dB) Gate Kit - GCK400 (WRI400 Out Door, PIM400- TD2, PIM Power Supply, and ANT400-REM-I/O) Mid-June 2011 ordering Elevator Kit - ECK400 (WRI400, PIM400-TD2, PIM Power Supply, and ANT400-REM-Ceiling) Mid-June 2011 ordering March 12 Technical Services Engineering Support 21
22 Legacy WRI and WRI400 Wire Same Type, part number, Same Maximum Lengths (User Guide) March 12 Technical Services Engineering Support 22
23 LEGACY PRODUCTS WRI400 AD SERIES Specifications FCC Part 15, Class B, FCC Part 15, Class B UL 294 UL F to +151 F -31 F to +151 F Plastic Enclosure Outdoor option Plastic Enclosure, and larger than a WRI Legacy Weather Tight March 12 Technical Services Engineering Support 23
24 WRI400 Set-Up HHD Connection Automatic - HHD Diagnostics from the PIM400 for RTE, RTX, DPS and Lid Tamper (ala AD400) In the User Guide and the Lid Label HHD COUPLING - Hold the WRI400 SCHLAGE Button, hit the WRI400 LINK three times CONSTRUCTION - Hold the WRI400 SCHLAGE button and present the card to be Master Construction Credntial, use the Master Construction to enroll construction user access cards LINKING - Press the WRI400 LINK button for 3 seconds (Always do the PIM400 first) FDR - Hold the WRI400 Schlage & LINK for 3 seconds TEST - Hold the WRI400 SCHLAGE and press RESET button, after re-boot, all LED & RELAY change state and the end of the reset re-boot. March 12 Technical Services Engineering Support 24
25 WRI400 AD SERIES LINKING LINK to PIM /TD2 Door number assignment LINKING to a PIM400 - HHD assigns door number when LINKING to a PIM , LINK 0 or LINK 1 manually when LINKING to a PIM400-TD2 Just like an AD400 March 12 Technical Services Engineering Support 25
26 SUS Settings for the WRI400 SUS HHD Screens for the WRI400 March 12 Technical Services Engineering Support 26
27 March 12 Technical Services Engineering Support 27
28 March 12 Technical Services Engineering Support 28
29 March 12 Technical Services Engineering Support 29
30 March 12 Technical Services Engineering Support 30
31 SUS HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 31
32 SUS HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 32
33 SUS HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 33
34 SUS HHD Screens for the WRI400 from PIM400 Diagnostics March 12 Technical Services Engineering Support 34
35 WRI400 Lid Label, and in the User Guide LED blinks, LINK, FDR, Coupling, Construction mode and Test March 12 Technical Services Engineering Support Confidential 35
36 USER GUIDE March 12 Technical Services Engineering Support Confidential 36
37 User Guide March 12 Technical Services Engineering Support Confidential 37
38 WRI400 Ah-Ha s Review No power is provided to the READERS (wave57830) Using Bright Blue or an OEM Access Control Panel Add the WRI400 just like the AD400 Or Add as a Legacy WRI, using a Legacy configured PIM400 SMS & BrightBlue update schedule for fall 2011 WRI400 has no integrated BUZZ-in feature. Just wire the Buzz-in switch across the WRI400 strike relay output. Might get a Forced Door WRI400 has no ALARM feature, alarm relay is not controlled by the WRI400 firmware. You must use the ACP to control the AUX for an alarm function. READER LED & BEEPER control are dependent on the as-ordered READER. The WRI400 can not completely control READER LED and BEEPER 100%. March 12 Technical Services Engineering Support 38
PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board
*P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,
More informationCT5000. Offline controller user guide Instructions for Adaptable Series offline controller _C LED2 USB USB SCHLAGE STRIKE RELAY STATUS +5V
TP2 TP22 TP23 TP24 TP25 ALR_ ALR_ ALR_N MLR VDD RB7 RB8 OPEN IDAT ILK RX 3.3V TX N N *P56-04* P56-04 T5000 Offline controller user guide Instructions for Adaptable Series offline controller J3 J S3 MOUNT
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationAD-300 AD-301. Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks
*P516-128* P516-128 AD-300 AD-301 Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks Para el idioma español, navegue hacia www.allegion.com/us. Pour la portion
More informationAD-300 AD-301. Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks
*P516-128* P516-128 AD-300 AD-301 Networked hardwired lock user guide Instructions for adaptable series networked hardwired locks Para el idioma español, navegue hacia www.schlage.com/support. Pour la
More informationSPX-7400_SPX-7410_MAN_161028
Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationSuprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316
CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation
More informationSPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz
SPX-5000 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5601 2.4GHz RPT-5651 2.4GHz Repeater SPX-5521 900 Mhz IOX-7621 2.4GHz EXP-2000 SPX-6601 2.4GHz SPX-5000_MAN_082112 This
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationSuprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502
Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More informationAD-400 AD-401. Networked wireless lock user guide Instructions for adaptable series networked wireless locks
*P516-127* P516-127 AD-400 AD-401 Networked wireless lock user guide Instructions for adaptable series networked wireless locks Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion
More informationNetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers
NetGen Hardware Installation Guide for NetGen Ethernet Door Controllers 0613 Table of Contents BLUEWAVE SYSTEM OVERVIEW...2 THE WI-FI LOCK AND SECURITY COMPANY...2 NETGEN DOOR CONTROLLERS...2 INSTALLATION
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationINSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:
INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationAD-300 AD-301 NETWORKED HARDWIRED LOCK USER GUIDE
P516-128 AD-300 AD-301 NETWORKED HARDWIRED LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES NETWORKED HARDWIRED LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française,
More informationKP2000E/EM Series Style Keypad
23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact
More informationSuprex Ethernet SPX-7200 Ethernet Reader-Extender
Suprex Ethernet SPX-7200 Ethernet Reader-Extender Product Manual 1 SPX-7200_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems
More informationApril 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control
Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More informationAccess control panel U-Prox IC E (Elevator control)
1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationThe Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.
Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom
More informationJanuary 2019 PRICE SCHEDULE A 2.0 Access Control Devices
January 2019 PRICE SCHEDULE A 2.0 Section A3 This Price Schedule is effective January 7, 2019. Date Page Comment 1-2-19 All January, 2019 Price Schedule update. 2-5-19 13 Corrected information listed under
More informationAD-400 AD-401. Networked wireless lock user guide Instructions for adaptable series networked wireless locks
*P516-127* P516-127 AD-400 AD-401 Networked wireless lock user guide Instructions for adaptable series networked wireless locks Para el idioma español, navegue hacia www.allegion.com/us Pour la portion
More informationJanuary 2018 PRICE SCHEDULE A 2.0 Access Control Devices
Section A3 This Price Schedule is effective January 1, 2018. Date Page Comment 1-1-18 All January, 2018 Price Schedule update. 3-21-18 21 Added 1804-701, 1804-705, 1804-706 LED retrofit kits. 4-24-18 25
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationSPX-7400 Series. Operations Manual. Suprex Reader Extender - Fiber Optic Interface. SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112
SPX-7400 Series Operations Manual Suprex Reader Extender - Fiber Optic Interface SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112 This manual covers the operation and setup of the Cypress Suprex Fiber
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More informationTHE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology
THE BRIDGE Make any Wiegand device wireless with the Surefi Bridge *Housing options sold separately. Keep your Wiegand system connected. Fix faulty Wiegand systems quickly and easily with our wireless
More informationNetAXS. Cloud-Hosted Services. Cloud Hosted Access Control. Retail Property Management Franchises
Cloud-Hosted Services NetAXS Cloud Hosted Access Control NetAXS is now integrated with MAXPRO Cloud. MAXPRO Cloud is a fully integrated Access Control and Video Security as a service platform. Ideal for
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationJanuary 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control
January 2013 PRICE SCHEDULE A 2.0 Section A4 Date Page Comment 1 1 13 All January, 2013 Price Schedule update. 2 13 13 6 Removed 1812 092 from 1812 145 kit. Added 1812 092 to 1812 147 kit. 2 13 13 9 P/N
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationPyramid Series Proximity Readers
The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom formats) or magnetic
More informationAC-115 Compact Networked Single-Door Controller Hardware Installation and Programming
AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,
More informationSECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)
SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 931 EntryCheck The
More informationClick Save to return to the main Setup screen.
ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationBrivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001
Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ENG-WI-001 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationAllegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements
Allegion Schlage AD-300 networked, hardwired locks can be integrated seamlessly with the Doors.NET software when used with the NXT-MSC (Mercury-Powered controllers). You can connect and communicate with
More informationStand-alone Proximity Access Control
Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses
More informationInstallation Instructions
Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line
More informationMR51e Reader Interface
J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationINSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries
INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION
More informationCYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314
CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.
More informationKey Switch. Document version: 1.5 (Updated 02 May 2017)
Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More information1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More informationTB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.
NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationNetAXS. Hosted Video Services. Cloud Hosted Access Control. Retail Professional Services Convenience
Hosted Video Services NetAXS Cloud Hosted Access Control NetAXS is now integrated with MAXPRO Cloud. MAXPRO Cloud is a fully integrated Access Control and Video Security as a service platform. Ideal for
More information-DTZ001- Stand-Alone Proximity Access Control. User Manual
-DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,
More information900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note
*44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationRBR-SB-KTZ001 LAR 2. User Manual
RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationModel MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly
Model MUGAPLM Multi-Unit Gate Access Panel Overview The Multi-Unit Gate Access Panel (MUGAPLM) uses a digitally secure intercom link that allows it to control up to four gate operators and other accessories.
More informationWiring Inside the card reader you will see a circuit board. The connections are as follows:
Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationVIDI-AC-2CS Access Controller/ Reader
VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS
More informationACTsmart2 Product Range Operating and Installation Instructions
ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More informationicam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box
icam7000s SERIES HARDWARE GUIDE ADVANCED MULTIFACTOR BIOMETRIC IRIS READER VERSION 1.0 icam7000s-t (Titanium Color) icam7000s-b (Black Color) DUAL IRIS ISO/ANSI COMPLIANT FACE CAMERA EASY INSTALLATION
More informationACS5000 Panel (A/E/S) Installation Manual
ACS5000 Panel (A/E/S) Installation Manual Rev 1 ENG-DOC-003 ACS5000 Installation Manual Page 2 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationNetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup
NetworX Series NX-0E RELAY EXPANDER NX-0E OUTPUT EXPANDER Installation and Startup NX-0E / NX-0E AUXILIARY MODULES TABLE OF CONTENTS I. GENERAL DESCRIPTION... II. WIRING INFORMATION... III. NX-0E TERMINAL
More informationU-FLASH Setup Guide U-FLASH.
U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationistar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More informationSection A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment
April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationInstallation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...
NX-0 RELAY EXPANDER NX-0 OUTPUT EXPANDER Installation Manual GENERAL DESCRIPTION... WIRING INFORMATION FOR NX-0 AND NX-0... NX-0 TERMINAL DESCRIPTION... NX-0 DRAWING... NX-0 TERMINAL DESCRIPTION... NX-0
More informationA list of distributors can be found on our website at -
8/04/203 Ins-30075-EX Net2 nano control unit Paxton For technical help please contact your distributor A list of distributors can be found on our website at - http://paxton.info/508 Documentation on all
More informationDESIGN GUIDE FOR INFINITY SYSTEMS
Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...
More informationInstallation Instructions (KF-2000)
VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809
More informationQuick Start Guide. SEB-710 I/O Expansion board. Introduction
SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay
More informationCamden - Key Switches
- Key Switches CM1120 - Flush Mount Key Switch 1 SPDT Momentary CM1130 - Flush Mount Key Switch 1 SPDT Maintained CM1120 CM1120 CM1120 CM2020 - Narrow Style Key Switch 1 SPDT Momentary CM2030 - Narrow
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationHow to Install a PowerNet IPBridge
How to Install a PowerNet IPBridge Copyright 2013, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION... 4 1.1: BEFORE YOU BEGIN... 4 1.2: GENERAL REQUIREMENTS:... 5 1.3: POWERNET
More information