ATS l AU AUTOMATIC TRANSFER SWITCH
|
|
- Leo Brown
- 6 years ago
- Views:
Transcription
1 ATS l AU AUTOMATIC TRANSFER SWITCH
2 MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces a novel design of Automatic Changeover Switch ideally suited for quick, safe and reliable transfer of load between two energy supply sources automatically.
3 INDEX AU AUTOMATIC TRANSFER SWITCH 3 ATS CONTROL 11 ENCLOSURES 19 INSTALLATION & DIMENSIONS 23 CATALOG NO. 31
4
5 AU AUTOMATIC TRANSFER SWITCH
6 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH POWER GENERATION EXPERTISE Several decades of experience and contribution to power generation technology have allowed Maschinenbau Halberstadt GmbH to conceptualize and tailor the ideal low Several decades of experience and contribution to power generation technology have voltage transfer switch that enables: Quick, safe and reliable transfer. Secure isolation. Minimum energy consumption. Minimizing downtime and service continuity. 4
7 MAIN APPLICATIONS The transfer switch serves as an equipment to transfer load supply service between two sources. Utility to Generator For application with single utility feeder and a standby generator source. The transfer switch senses loss or abnormality in utility voltage then issues a remote start signal to the standby generator and transfers the load. Load is transferred back under normal utility conditions. LOAD Generator to Generator For application in a power system with multiple site generators. Load is transferred to secondary generation in the events of failure or scheduled maintenance. LOAD Utility to Utility For application with multiple utility feed. Transfer from one source to another is enabled in case of scheduled maintenance of source failure. LOAD Multiple Source System Multiple Source Systems may include multiple redundant utility feeds and/or multiple standby generators. Load is transferred to standby source in the event of utility (ies) failure in the case of multiple utility feeds. Load transfer to secondary generator is accomplished following the failure of both utility and standby generators. LOAD 5
8 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH GENERAL CHARACTERISTICS The ATS is intended for use in low voltage power networks in order to reduce and virtually eliminate outage periods of critical loads. The ATS ratings range from 100A to 3000A to cover the widest range of industrial, commercial and residential needs. Extended product lifetime through minimization of arcing time. On-Load Switching. Manual Bypass Capabilities. Dual switching strategies: 3 Stable switch positions (Main Source, Neutral, Emergency Source). Main Emergency or Main Neutral Emergency. Individual phase enclosure and arc chamber to improve breaking capacity. Enhanced main contact protection & breaking capacity. Easy to maintain. High transfer capabilities for inductive and motor loads. Arc Chamber 6
9 AUT FEATURES 100~3000A MBH AU s unique design is optimized to ensure personnel safety, equipment protection and virtually eliminating outages thus combining safety, reliability and fast response. It is widely trusted to maintain service of critical and non-critical processes online at all time to enhance our client s manufacturing capabilities. Safety All phases are fully insulated, each in its unique structure. The breaking chambers are fully enclosed to prevent contact with any live parts caused by insulation degradation following an arcing event. Safe conductive performance is ensured by applying adequate contact pressure at all times during operation. Compact Design Each phase is fully insulated and is in an independent 1-phase structure. According to the convenience of users, the conduction parts of 3-phase and 4-phase can be combined depending on the capacity and the number of phases. The compact and unique design allows for switching between main source and emergency source through the use of one coil. The uniquely structured arc shute reduces the arc breaking time leading to longer contact lifetime. Stable breaking is ensured by the use of a breaking spring for tripping operations. Low loss and low energy consumption due to the application of instantaneous excitation mode. Both direct source transfer and transfer through neutral stable position are possible. Reference Standards The AU Automatic Transfer Switches are designed, manufactured and tested incompliance with the following standards: IEC EN IEC EN
10 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU Technical Description 8
11 9
12
13 ATS CONTROL
14 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU CONTACT TIME CHART & CIRCUIT DIAGRAM AU Contact Time Chart AU Internal Circuit 12
15 AU Operating Circuit 13
16 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AUC 173 DIN RAIL MOUNTED Features DIN Rail mounted. No DC supply required. Adjustable MCB and GCB delays. 10A/250VAC MCB and GCB outputs. 10A/28VDC/250VAC remote start output. Isolated mains and genset inputs. Inputs R-S-T: Mains phase voltages. G: Generator phase voltage. NEUT-MN: Mains neutral terminal. NEUT-GN: Generator neutral terminal. Outputs MCB-MAINS Contactor: Normally open relay output connecting the phase-r voltage to the terminal. Remote Start: Normally open engine start request relay output. GCB-Generator Contactor: Normally open relay output connecting the phase-g voltage to the terminal. Technical Specifications Alternator Voltage: V-AC (Ph-N). Mains Voltages: V-AC (Ph-N). MCB Relay Output: 250V-AC. GCB Relay Output: 250V-AC. Maximum humidity: 95% noncondensing. Dimensions: 70x115x66mm (WxHxD). Weight: 180g (approx.). Installation: DIN Rail mounted. IP Protection: IP20. Conformity (EU directives). 2006/95/EC (low voltage). 2004/108/EC (EMC). Norms of reference: Generator Contactor Delay: 1 to 40 sec. adjustable. Mains Return Delay: 1 to 40 sec. adjustable. Remote Start Relay Output: Operating temp.: -30 C (-22 F) to 70 C (158 F). Storage temp.: -30 C (-22 F) to 80 C (176 F). Case Material: High Temp. ABS/PC (UL94-V0). EN (safety requirements). EN (EMC requirements). 14
17 15
18 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AUC 329 ATS CONTROLLER WITH MULTIPLE GENSET SUPPORT Features Automatic contactor control. Built in alarms and warnings. Statistical counters. 3 level password system. Field adjustable parameters. RS-232 serial port. Synchroscope & check synch. No break transfer & no break load test. Multiple genset system support. Electrical protections for genset. Load shedding, dummy load. Periodic maintenance request indicator. Built in daily / weekly / monthly exerciser. Event logging with time stamp and measurements. Battery backed-up real time clock. Weekly operation schedule programs. Firmware downloadable from serial port. Free MS-Windows Remote monitoring SW: Local and modem connection. Monitoring, download of parameters. Modem networking. GSM and PSTN modem support. GSM SMS message sending on fault. MODBUS communications. Graphic LCD display (128x64 pixels). User friendly graphic indicators. Triple language support. Customer logo display capability. Configurable digital inputs: 7. Configurable digital outputs: 2. Total digital outputs: 6. I/O expansion capability. Survives cranking dropouts. Sealed front panel. Plug-in connection system for easy replacement. 16
19 Inputs The unit has 7 configutable digital inputs. Each input has following programmable parameters: Alarm type: shutdown / load-dump / warning / no alarm. Alarm polling: on engine running / always / on mains OK. Latching / non-latching operation. Contact type: NO / NC. Switching: BAT+ / BAT. Outputs The unit provides 6 digital outputs and 2 of them have programmable functions, selectable from a list. Any function or alarm condition may be output as a relay output. Using two Relay Expansion Modules, the number of relays may be increased to 22, 16 of them being voltfree contacts. Alternator voltage: 0 to 300 V-AC (Ph-N). Alternator frequency: Hz. Mains voltage: 0 to 300 V-AC (Ph-N). Mains frequency: Hz. DC Supply Range: 9.0 to 30.0 V-DC. Typical Standby Current: 100 ma-dc. DC Outputs: 28V. Weight: 300 g (approx). Conformity (EU directives). 2006/95/EC (low voltage). Norms: EN (safety requirements). Cranking dropouts: survives 0 V for 100ms. Maximum Operating Current: 200 ma-dc. (Relay outputs open) Generator/Mains Contactor Relay Outputs: 16 A / 250V. Current inputs: from CTs,.../5A. Max load 0.7VA per phase. Serial port: RS-232, 9600 bauds, no parity, 1 bit stop. Operating temperature: -20 C (-4 F) to 70 C (158 F). Storage temperature: -40 C (-40 F) to 80 C (176 F). Maximum humidity: 95% non-condensing. Dimensions: 165 x 125 x 48 mm (WxHxD). Panel Cut-out Dimensions: 151x111 mm minimum. Case Material: High Temperature ABS/PC (UL94-V0). IP Protection: IP65 from front panel, IP30 from the rear. 2004/108/EC (electro-magnetic compatibility). EN (EMC requirements). 17
20
21 ENCLOSURES
22 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH The enclosed ATS dimensions are optimized to fit in small areas while facilitating the installation and maintenance for all its parts. The enclosed ATS line provides the user with a secure and reliable solution under a wide range of environmental and physical dangers. Enclosed ATS range can be customized to fit all your needs. Standard Enclosures (mm) Rating(A) IP Voltage Poies Width Depth Height 100A, 200A V 3P, 4P A, 600A V 3P, 4P A, 1000A V 3P, 4P A, 1600A V 3P, 4P Custom Design 2000A V 3P, 4P Custom Design 3000A V 3P, 4P Custom Design 20
23 21
24
25 INSTALLATION & DIMENSIONS
26 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH MANUAL OPERATION Manual operation is made feasible through the use of a handle connected to the side of the ATS and by making use of a metal pin to control source selection and tripping. Manual Bypass to Source A Source A: ON Manual Bypass to Source B Source B: ON Trip Source A: OFF Source B: OFF CAUTION: ATS Manual operation should be carried out under no load conditions and after careful inspection of live parts. 24
27 OPERATING CONDITIONS Ambient Conditions Avoid installation in humid areas, locations with risk of exposure to poisonous gas and high temperature places. Orientation The ATS is designed to be installed in a specific direction as highlighted in the figure. The ATS feature and performance may be subject to variation if the installation orientation changes. Ideally, the ATS should be installed so as the nameplate can be read properly facing the front and without any twist or bending of any ATS components. Control Circuit Connection Use low voltage control/power cable with sufficient length. In case of DC supply, make sure to take into consideration battery and charging characteristics. Main Circuit Connection Connect firmly by selecting appropriate wire sizes and solderless terminals. Avoid applying excessive stress to the main circuit terminal. Maintenance & Inspection Conduct maintenance and inspection at regular cycles in order to maintain the ATS performance. Recommended NOT Recommended 25
28 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU DIMENSIONS AU 100A - AU 200A (Front) Type 3P 4P A B AU 400A (Front) Type 3P 4P A B
29 AU 600A - AU 1000A (Front) AU600 AU800 AU1000 3P 4P 3P 4P 3P 4P A B C D E F G H I J K L M
30 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU 1200A - AU 1600A (Front) AU1200 AU1600 3P 4P 3P 4P A B C D E F G H I J K L M N
31 AU 2000A (Back) AU1200 3P 4P A B C - - D - - E F G H I J - - K L - - M - - N
32 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU 3000A (Back) AU3000 3P 4P A B C D
33 CATALOG NO. AUTOMATIC TRANSFER SWITCH Model AU Automatic Changeover Switch Switch Type S Standard AC Installation F Front Connection B Back Connection Controller c1 AUC 329 c2 AUC 173 Poles 3 3P 4 4P Supply voltage (shunt trip) V V Current Rating A A A A A A A A A A Enclosure ** Protection Index ** Specify Protection Index 31
34
35
36 MBH Middle East & Africa Halat, Lebanon T middleeast@mbhelectric.de MBH Gulf Baniyas Complex Nasser Square Al Rigga Area Deira, Dubai, UAE T , F dubai@mbhelectric.de MBH Headquarters MASCHINENBAU HALBERSTADT GmbH Rudolf Diesel-Strasse 50 Halberstadt Germany T , F info@mbhelectric.de Maschinenbau Halberstadt GmbH All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.
ATS l AU AUTOMATIC TRANSFER SWITCH
ATS l AU AUTOMATIC TRANSFER SWITCH MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces a novel design of Automatic Changeover Switch ideally suited for quick,
More informationNorth Power 5H04 PRIME POWER:454 KVA KW STANDBY POWER: 504 KVA KW
DATA SHEET North Power 5H04 STANDBY POWER: 504 KVA - 403 KW Standard Specifications Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter
More informationDKG-210 UNIVERSAL INTERNET GATEWAY UNIT
DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationPRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet
Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part
More informationHAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...
More informationDual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx
D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with
More informationPRODUCT SPECIFICATION. PC Board Relays. Series.
PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7
More informationSENTRON ATC Automatic Transfer Control Device
Siemens A 2010 SENTRON - SENTRON switching, protection and measuring devices The SENTRON, when equipped with two motor-driven circuit breakers, serves as a transfer system that automatically or manually
More informationCompact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus
DATA SHEET Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationATS CONTROLLER OPERATING MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1
More informationComprehensive Modular Genset Controller
Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the
More informationHAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL
HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationControl unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~
Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY
More informationSafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay
EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite
More informationProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.
ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationDATA SHEET Compact Genset Controller, CGC 200
DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationXitanium. LED driver. Datasheet. Xitanium LED drivers - linear LV isolated. Xitanium 25W 0.5/0.6A 42V V
Xitanium LED driver Datasheet Xitanium LED drivers - linear LV isolated Xitanium 25W 0.5/0.6A 42V 13 230V Optimizing Performance Xitanium LED drivers are designed to operate LED solutions for general lighting
More informationXitanium LED drivers spot and downlight fixed output LED driver 30W 400mA 69V 230V
Xitanium LED drivers spot and downlight fixed output LED driver 30W 400mA 69V 230V Enabling future-proof LED technology Xitanium LED drivers are designed to operate LED solutions for general lighting applications.
More informationYour technology partner Datakom, innovative products, affordable prices.
Your technology partner Datakom, innovative products, affordable prices. GENSET PRODUCTS Synchronization Units Multifunctional Units The D-700 is a comprehensive genset controller capable of all possible
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationHF-Selectalume TL-D II
HF-Selectalume TL-D II Electronic ballasts for TL-D lamps Product Description Affordable, reliable, high frequency electronic ballast for TL-D fluorescent lamps Product Features and Benefits Energy efficient
More informationPolymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3
Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger
More informationCertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers
CertaDrive LED indoor drivers 1 Published versions 2 Contents Contents 3 Introduction to this guide 4 Applications 4 Information or support 4 Safety precautions 5 Safety warnings and installation instructions
More informationSwitched Mode Power Supply Operating manual PAP800
Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationQUINT-PS/24DC/48DC/ 5
Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog
More informationGPM500 Generator Protection Module
GPM500 Generator Protection Module Generator Protection Module GPM500 The microprocessor based Generator Protection System GPM500 performs the protection and control of medium and low voltage generators
More informationProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring
Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal
More informationXitanium Dim 100W 0.8A 1-10V 230V I175
Xitanium LED Driver Datasheet LED-based light sources are an excellent solution for outdoor environment. They are long-lasting and require low maintenance. However, to get the best out of the LEDs, these
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationAUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES
AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES 2 power sources automatic transfer switch controllers The automatic transfer switch controllers ATL 600 - ATL 610 - ATL 800 can supervise and manage the
More informationSoft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.
Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0
More informationXitanium Outdoor LED Drivers Single Current
Xitanium LED driver Datasheet Xitanium Outdoor LED Drivers Single Current LED-based light sources are an excellent solution for outdoor environments. They are long-lasting and require low maintenance.
More informationUltra Slim Relays 24
Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest
More informationProduct Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx
ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side
More informationTECHNICAL DESCRIPTION
MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up
More informationControl unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V
Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationDKM-407 DIN RAIL TYPE NETWORK ANALYZER
DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution
More informationIO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs
IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The
More informationXitanium. Xitanium 150W 0.7A 230V Y. LED Driver. Datasheet
Xitanium LED Driver Datasheet Xitanium 150W 0.7A 230V Y LED-based light sources are an excellent solution for outdoor environment. They are long-lasting and require low maintenance. However, to get the
More informationXitanium Highbay LED Drivers Dimmable (1-10V) Independent
Xitanium LED driver Datasheet Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium Dim 100W 1.05A 1-10V 230V I165 LED-based light sources are an excellent solution for highbay industrial
More informationWSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL
WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller
More information100% electricity. Automatic transfer switch controllers ATL series
100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC
More informationDocumentation. KM2604 and KM2614. Four channel relay module. Version: Date:
Documentation KM2604 and KM2614 Four channel relay module Version: Date: 2.1.0 2017-12-01 Tabel of contents Tabel of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...
More informationRapidus Power Factor Controller
Rapidus Power Factor Controller Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system Dynamic Capacitor Monitoring DCM is a supreme
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationUSER MANUAL 2012 V1.1
SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information
More informationDeltaV SIS Conditioning Components
DeltaV SIS Process Safety System DeltaV SIS Conditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements.
More informationMULTICHANNEL DATA RECORDERS
MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000
More information1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output
More informationData Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D
WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low
More informationESB ⅓ Hz 440Hz. Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/230Vac 16A, 16 ⅓ Hz 440Hz, - 40 C...
ESB101 Made in Germany Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/ 16A, 16 ⅓ Hz 440Hz, - 40 C... +60 C Short Specification: Peak- / R.M.S. current limiter 90-130Vac
More informationCurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.
CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring
More informationMETERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.
LTD METERSUK sales@meters.co.uk 01524 555 929 3 MOD CT Series Smart Energy Meter KEY FEATURES Three phase metering Three Phase metering, 7 din modules Accuracy class 1 according to IEC62053-21 LCD display,
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationXitanium Highbay LED Drivers Dimmable (1-10V) Independent
Xitanium LED driver Datasheet Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium Dim 100W 1.05A 1-10V 230V I165C LED-based light sources are an excellent solution for highbay industrial
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationXitanium Highbay LED Drivers Dimmable (1-10V) Independent
Xitanium LED driver Datasheet Xitanium Highbay LED Drivers Dimmable (1-1V) Independent Xitanium Dim 22W 1.5A 1-1V 23V I24C LED-based light sources are an excellent solution for highbay industrial applications.
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationRSTI-EP Slice I/O. Digital Output Module
GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status
More informationKeor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world
More informationEnergy meters Single phase electrical energy meters WM1-6 / WM1M6
Energy meters Single phase electrical energy meters WM1-6 / WM1M6 o Single phase direct connected DIN-rail mounting meter o Class 1 for active energy according to EN 62053-21 and B according to EN 50470-3
More informationIso DIN. User Manual. 1 channel Earth Fault Monitoring
Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee
More informationTable of Contents. Safety. Attention. Warnings
Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure
More informationInstallation and User Guide
D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect
More informationLED driver 40W 1050mA 40V s 230V
Electrical input data minal input voltage 220...240 Vac minal input frequency 47.5...63 Hz minal input current 0.19 minal input power 43 W Power factor 0.96 Total harmonic distortion 10 Efficiency 87,
More informationQUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE
QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form
More informationInteliLite MRS17 Click Here to Learn More
InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R MP7
Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationMCX08M2 Programmable controller
Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationHGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology
HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationOperating Instructions
Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationDupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications
Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter
More informationProven robustness and reliable electronic driver design. Robust design; capable of withstanding harsh outdoor conditions.
Xitanium LED driver Datasheet Xitanium Outdoor LED Drivers Dimmable (1-10V) Independent Xitanium Dim 250W 0.70A 1-10V 230V I220C LED-based light sources are an excellent solution for outdoor environment.
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More informationDigital Speed Controller User Manual
Diesel Engine for Generators Digital Speed Controller User Manual (DSC-1000) Ver_1.0 Doosan Infracore 페이지 1 / 36 Contents 1. Product Overview and General Specification 1.1 Product Information 1.2 Product
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationOperating Manual. English. Digital-Analog Converter DACON8-UMB.
English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before
More informationDKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY
datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision
More informationLOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E
LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationDocumentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:
Documentation Sixteen Channel Digital Output Module with D-Sub Connector Version: Date: 2.0 2016-08-03 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationTemperature controller Ducted systems
2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More information