ATS l AU AUTOMATIC TRANSFER SWITCH

Size: px
Start display at page:

Download "ATS l AU AUTOMATIC TRANSFER SWITCH"

Transcription

1 ATS l AU AUTOMATIC TRANSFER SWITCH

2 MASCHINENBAU HALBERSTADT GmbH, building on its 60 year legacy in power generation, introduces a novel design of Automatic Changeover Switch ideally suited for quick, safe and reliable transfer of load between two energy supply sources automatically.

3 INDEX AU AUTOMATIC TRANSFER SWITCH 3 ATS CONTROL 11 ENCLOSURES 19 INSTALLATION & DIMENSIONS 23 CATALOG NO. 31

4

5 AU AUTOMATIC TRANSFER SWITCH

6 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH POWER GENERATION EXPERTISE Several decades of experience and contribution to power generation technology have allowed Maschinenbau Halberstadt GmbH to conceptualize and tailor the ideal low Several decades of experience and contribution to power generation technology have voltage transfer switch that enables: Quick, safe and reliable transfer. Secure isolation. Minimum energy consumption. Minimizing downtime and service continuity. 4

7 MAIN APPLICATIONS The transfer switch serves as an equipment to transfer load supply service between two sources. Utility to Generator For application with single utility feeder and a standby generator source. The transfer switch senses loss or abnormality in utility voltage then issues a remote start signal to the standby generator and transfers the load. Load is transferred back under normal utility conditions. LOAD Generator to Generator For application in a power system with multiple site generators. Load is transferred to secondary generation in the events of failure or scheduled maintenance. LOAD Utility to Utility For application with multiple utility feed. Transfer from one source to another is enabled in case of scheduled maintenance of source failure. LOAD Multiple Source System Multiple Source Systems may include multiple redundant utility feeds and/or multiple standby generators. Load is transferred to standby source in the event of utility (ies) failure in the case of multiple utility feeds. Load transfer to secondary generator is accomplished following the failure of both utility and standby generators. LOAD 5

8 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH GENERAL CHARACTERISTICS The ATS is intended for use in low voltage power networks in order to reduce and virtually eliminate outage periods of critical loads. The ATS ratings range from 100A to 3000A to cover the widest range of industrial, commercial and residential needs. Extended product lifetime through minimization of arcing time. On-Load Switching. Manual Bypass Capabilities. Dual switching strategies: 3 Stable switch positions (Main Source, Neutral, Emergency Source). Main Emergency or Main Neutral Emergency. Individual phase enclosure and arc chamber to improve breaking capacity. Enhanced main contact protection & breaking capacity. Easy to maintain. High transfer capabilities for inductive and motor loads. Arc Chamber 6

9 AUT FEATURES 100~3000A MBH AU s unique design is optimized to ensure personnel safety, equipment protection and virtually eliminating outages thus combining safety, reliability and fast response. It is widely trusted to maintain service of critical and non-critical processes online at all time to enhance our client s manufacturing capabilities. Safety All phases are fully insulated, each in its unique structure. The breaking chambers are fully enclosed to prevent contact with any live parts caused by insulation degradation following an arcing event. Safe conductive performance is ensured by applying adequate contact pressure at all times during operation. Compact Design Each phase is fully insulated and is in an independent 1-phase structure. According to the convenience of users, the conduction parts of 3-phase and 4-phase can be combined depending on the capacity and the number of phases. The compact and unique design allows for switching between main source and emergency source through the use of one coil. The uniquely structured arc shute reduces the arc breaking time leading to longer contact lifetime. Stable breaking is ensured by the use of a breaking spring for tripping operations. Low loss and low energy consumption due to the application of instantaneous excitation mode. Both direct source transfer and transfer through neutral stable position are possible. Reference Standards The AU Automatic Transfer Switches are designed, manufactured and tested incompliance with the following standards: IEC EN IEC EN

10 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU Technical Description 8

11 9

12

13 ATS CONTROL

14 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU CONTACT TIME CHART & CIRCUIT DIAGRAM AU Contact Time Chart AU Internal Circuit 12

15 AU Operating Circuit 13

16 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AUC 173 DIN RAIL MOUNTED Features DIN Rail mounted. No DC supply required. Adjustable MCB and GCB delays. 10A/250VAC MCB and GCB outputs. 10A/28VDC/250VAC remote start output. Isolated mains and genset inputs. Inputs R-S-T: Mains phase voltages. G: Generator phase voltage. NEUT-MN: Mains neutral terminal. NEUT-GN: Generator neutral terminal. Outputs MCB-MAINS Contactor: Normally open relay output connecting the phase-r voltage to the terminal. Remote Start: Normally open engine start request relay output. GCB-Generator Contactor: Normally open relay output connecting the phase-g voltage to the terminal. Technical Specifications Alternator Voltage: V-AC (Ph-N). Mains Voltages: V-AC (Ph-N). MCB Relay Output: 250V-AC. GCB Relay Output: 250V-AC. Maximum humidity: 95% noncondensing. Dimensions: 70x115x66mm (WxHxD). Weight: 180g (approx.). Installation: DIN Rail mounted. IP Protection: IP20. Conformity (EU directives). 2006/95/EC (low voltage). 2004/108/EC (EMC). Norms of reference: Generator Contactor Delay: 1 to 40 sec. adjustable. Mains Return Delay: 1 to 40 sec. adjustable. Remote Start Relay Output: Operating temp.: -30 C (-22 F) to 70 C (158 F). Storage temp.: -30 C (-22 F) to 80 C (176 F). Case Material: High Temp. ABS/PC (UL94-V0). EN (safety requirements). EN (EMC requirements). 14

17 15

18 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AUC 329 ATS CONTROLLER WITH MULTIPLE GENSET SUPPORT Features Automatic contactor control. Built in alarms and warnings. Statistical counters. 3 level password system. Field adjustable parameters. RS-232 serial port. Synchroscope & check synch. No break transfer & no break load test. Multiple genset system support. Electrical protections for genset. Load shedding, dummy load. Periodic maintenance request indicator. Built in daily / weekly / monthly exerciser. Event logging with time stamp and measurements. Battery backed-up real time clock. Weekly operation schedule programs. Firmware downloadable from serial port. Free MS-Windows Remote monitoring SW: Local and modem connection. Monitoring, download of parameters. Modem networking. GSM and PSTN modem support. GSM SMS message sending on fault. MODBUS communications. Graphic LCD display (128x64 pixels). User friendly graphic indicators. Triple language support. Customer logo display capability. Configurable digital inputs: 7. Configurable digital outputs: 2. Total digital outputs: 6. I/O expansion capability. Survives cranking dropouts. Sealed front panel. Plug-in connection system for easy replacement. 16

19 Inputs The unit has 7 configutable digital inputs. Each input has following programmable parameters: Alarm type: shutdown / load-dump / warning / no alarm. Alarm polling: on engine running / always / on mains OK. Latching / non-latching operation. Contact type: NO / NC. Switching: BAT+ / BAT. Outputs The unit provides 6 digital outputs and 2 of them have programmable functions, selectable from a list. Any function or alarm condition may be output as a relay output. Using two Relay Expansion Modules, the number of relays may be increased to 22, 16 of them being voltfree contacts. Alternator voltage: 0 to 300 V-AC (Ph-N). Alternator frequency: Hz. Mains voltage: 0 to 300 V-AC (Ph-N). Mains frequency: Hz. DC Supply Range: 9.0 to 30.0 V-DC. Typical Standby Current: 100 ma-dc. DC Outputs: 28V. Weight: 300 g (approx). Conformity (EU directives). 2006/95/EC (low voltage). Norms: EN (safety requirements). Cranking dropouts: survives 0 V for 100ms. Maximum Operating Current: 200 ma-dc. (Relay outputs open) Generator/Mains Contactor Relay Outputs: 16 A / 250V. Current inputs: from CTs,.../5A. Max load 0.7VA per phase. Serial port: RS-232, 9600 bauds, no parity, 1 bit stop. Operating temperature: -20 C (-4 F) to 70 C (158 F). Storage temperature: -40 C (-40 F) to 80 C (176 F). Maximum humidity: 95% non-condensing. Dimensions: 165 x 125 x 48 mm (WxHxD). Panel Cut-out Dimensions: 151x111 mm minimum. Case Material: High Temperature ABS/PC (UL94-V0). IP Protection: IP65 from front panel, IP30 from the rear. 2004/108/EC (electro-magnetic compatibility). EN (EMC requirements). 17

20

21 ENCLOSURES

22 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH The enclosed ATS dimensions are optimized to fit in small areas while facilitating the installation and maintenance for all its parts. The enclosed ATS line provides the user with a secure and reliable solution under a wide range of environmental and physical dangers. Enclosed ATS range can be customized to fit all your needs. Standard Enclosures (mm) Rating(A) IP Voltage Poies Width Depth Height 100A, 200A V 3P, 4P A, 600A V 3P, 4P A, 1000A V 3P, 4P A, 1600A V 3P, 4P Custom Design 2000A V 3P, 4P Custom Design 3000A V 3P, 4P Custom Design 20

23 21

24

25 INSTALLATION & DIMENSIONS

26 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH MANUAL OPERATION Manual operation is made feasible through the use of a handle connected to the side of the ATS and by making use of a metal pin to control source selection and tripping. Manual Bypass to Source A Source A: ON Manual Bypass to Source B Source B: ON Trip Source A: OFF Source B: OFF CAUTION: ATS Manual operation should be carried out under no load conditions and after careful inspection of live parts. 24

27 OPERATING CONDITIONS Ambient Conditions Avoid installation in humid areas, locations with risk of exposure to poisonous gas and high temperature places. Orientation The ATS is designed to be installed in a specific direction as highlighted in the figure. The ATS feature and performance may be subject to variation if the installation orientation changes. Ideally, the ATS should be installed so as the nameplate can be read properly facing the front and without any twist or bending of any ATS components. Control Circuit Connection Use low voltage control/power cable with sufficient length. In case of DC supply, make sure to take into consideration battery and charging characteristics. Main Circuit Connection Connect firmly by selecting appropriate wire sizes and solderless terminals. Avoid applying excessive stress to the main circuit terminal. Maintenance & Inspection Conduct maintenance and inspection at regular cycles in order to maintain the ATS performance. Recommended NOT Recommended 25

28 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU DIMENSIONS AU 100A - AU 200A (Front) Type 3P 4P A B AU 400A (Front) Type 3P 4P A B

29 AU 600A - AU 1000A (Front) AU600 AU800 AU1000 3P 4P 3P 4P 3P 4P A B C D E F G H I J K L M

30 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU 1200A - AU 1600A (Front) AU1200 AU1600 3P 4P 3P 4P A B C D E F G H I J K L M N

31 AU 2000A (Back) AU1200 3P 4P A B C - - D - - E F G H I J - - K L - - M - - N

32 MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU 3000A (Back) AU3000 3P 4P A B C D

33 CATALOG NO. AUTOMATIC TRANSFER SWITCH Model AU Automatic Changeover Switch Switch Type S Standard AC Installation F Front Connection B Back Connection Controller c1 AUC 329 c2 AUC 173 Poles 3 3P 4 4P Supply voltage (shunt trip) V V Current Rating A A A A A A A A A A Enclosure ** Protection Index ** Specify Protection Index 31

34

35

36 MBH Middle East & Africa Halat, Lebanon T middleeast@mbhelectric.de MBH Gulf Baniyas Complex Nasser Square Al Rigga Area Deira, Dubai, UAE T , F dubai@mbhelectric.de MBH Headquarters MASCHINENBAU HALBERSTADT GmbH Rudolf Diesel-Strasse 50 Halberstadt Germany T , F info@mbhelectric.de Maschinenbau Halberstadt GmbH All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.

ATS l AU AUTOMATIC TRANSFER SWITCH

ATS l AU AUTOMATIC TRANSFER SWITCH ATS l AU AUTOMATIC TRANSFER SWITCH MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces a novel design of Automatic Changeover Switch ideally suited for quick,

More information

North Power 5H04 PRIME POWER:454 KVA KW STANDBY POWER: 504 KVA KW

North Power 5H04 PRIME POWER:454 KVA KW STANDBY POWER: 504 KVA KW DATA SHEET North Power 5H04 STANDBY POWER: 504 KVA - 403 KW Standard Specifications Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

SENTRON ATC Automatic Transfer Control Device

SENTRON ATC Automatic Transfer Control Device Siemens A 2010 SENTRON - SENTRON switching, protection and measuring devices The SENTRON, when equipped with two motor-driven circuit breakers, serves as a transfer system that automatically or manually

More information

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus DATA SHEET Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

ATS CONTROLLER OPERATING MANUAL

ATS CONTROLLER OPERATING MANUAL HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the

More information

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay EN 954 SafeC S Safety Relay SafeC S: Narrow construction of only 22.5 mm SafeC S is a sturdy and extremely inexpensive safety relay which impresses with its unusual efficiency and versatility, despite

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

DATA SHEET Compact Genset Controller, CGC 200

DATA SHEET Compact Genset Controller, CGC 200 DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

Xitanium. LED driver. Datasheet. Xitanium LED drivers - linear LV isolated. Xitanium 25W 0.5/0.6A 42V V

Xitanium. LED driver. Datasheet. Xitanium LED drivers - linear LV isolated. Xitanium 25W 0.5/0.6A 42V V Xitanium LED driver Datasheet Xitanium LED drivers - linear LV isolated Xitanium 25W 0.5/0.6A 42V 13 230V Optimizing Performance Xitanium LED drivers are designed to operate LED solutions for general lighting

More information

Xitanium LED drivers spot and downlight fixed output LED driver 30W 400mA 69V 230V

Xitanium LED drivers spot and downlight fixed output LED driver 30W 400mA 69V 230V Xitanium LED drivers spot and downlight fixed output LED driver 30W 400mA 69V 230V Enabling future-proof LED technology Xitanium LED drivers are designed to operate LED solutions for general lighting applications.

More information

Your technology partner Datakom, innovative products, affordable prices.

Your technology partner Datakom, innovative products, affordable prices. Your technology partner Datakom, innovative products, affordable prices. GENSET PRODUCTS Synchronization Units Multifunctional Units The D-700 is a comprehensive genset controller capable of all possible

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

HF-Selectalume TL-D II

HF-Selectalume TL-D II HF-Selectalume TL-D II Electronic ballasts for TL-D lamps Product Description Affordable, reliable, high frequency electronic ballast for TL-D fluorescent lamps Product Features and Benefits Energy efficient

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

CertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers

CertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers CertaDrive LED indoor drivers 1 Published versions 2 Contents Contents 3 Introduction to this guide 4 Applications 4 Information or support 4 Safety precautions 5 Safety warnings and installation instructions

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog

More information

GPM500 Generator Protection Module

GPM500 Generator Protection Module GPM500 Generator Protection Module Generator Protection Module GPM500 The microprocessor based Generator Protection System GPM500 performs the protection and control of medium and low voltage generators

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

Xitanium Dim 100W 0.8A 1-10V 230V I175

Xitanium Dim 100W 0.8A 1-10V 230V I175 Xitanium LED Driver Datasheet LED-based light sources are an excellent solution for outdoor environment. They are long-lasting and require low maintenance. However, to get the best out of the LEDs, these

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES 2 power sources automatic transfer switch controllers The automatic transfer switch controllers ATL 600 - ATL 610 - ATL 800 can supervise and manage the

More information

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2. Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0

More information

Xitanium Outdoor LED Drivers Single Current

Xitanium Outdoor LED Drivers Single Current Xitanium LED driver Datasheet Xitanium Outdoor LED Drivers Single Current LED-based light sources are an excellent solution for outdoor environments. They are long-lasting and require low maintenance.

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Product Sheet ECO. Types ECG, AMF Technical data.  product sheet eco ecg-amf - technical data gb v1.0.docx ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

DKM-407 DIN RAIL TYPE NETWORK ANALYZER DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

Xitanium. Xitanium 150W 0.7A 230V Y. LED Driver. Datasheet

Xitanium. Xitanium 150W 0.7A 230V Y. LED Driver. Datasheet Xitanium LED Driver Datasheet Xitanium 150W 0.7A 230V Y LED-based light sources are an excellent solution for outdoor environment. They are long-lasting and require low maintenance. However, to get the

More information

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium LED driver Datasheet Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium Dim 100W 1.05A 1-10V 230V I165 LED-based light sources are an excellent solution for highbay industrial

More information

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL v 1.0 Thanks for choosing the Intelligent temperature and humidity controller

More information

100% electricity. Automatic transfer switch controllers ATL series

100% electricity. Automatic transfer switch controllers ATL series 100% electricity Automatic transfer switch controllers ATL series Automatic transfer switch controllers Keep control around the clock General characteristics Rated auxiliary power supply: 220-230-240VAC

More information

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date: Documentation KM2604 and KM2614 Four channel relay module Version: Date: 2.1.0 2017-12-01 Tabel of contents Tabel of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Rapidus Power Factor Controller

Rapidus Power Factor Controller Rapidus Power Factor Controller Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system Dynamic Capacitor Monitoring DCM is a supreme

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

USER MANUAL 2012 V1.1

USER MANUAL 2012 V1.1 SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information

More information

DeltaV SIS Conditioning Components

DeltaV SIS Conditioning Components DeltaV SIS Process Safety System DeltaV SIS Conditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements.

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

ESB ⅓ Hz 440Hz. Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/230Vac 16A, 16 ⅓ Hz 440Hz, - 40 C...

ESB ⅓ Hz 440Hz. Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/230Vac 16A, 16 ⅓ Hz 440Hz, - 40 C... ESB101 Made in Germany Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/ 16A, 16 ⅓ Hz 440Hz, - 40 C... +60 C Short Specification: Peak- / R.M.S. current limiter 90-130Vac

More information

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs. CurrentWatch Current Sensors Ground Fault Sensors with Solid-State or Mechanical Relay s 1 Contents Overview.................... 1 Model Selection, Switches...... 2 Model Selection, Accessories... 3 Wiring

More information

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. LTD METERSUK sales@meters.co.uk 01524 555 929 3 MOD CT Series Smart Energy Meter KEY FEATURES Three phase metering Three Phase metering, 7 din modules Accuracy class 1 according to IEC62053-21 LCD display,

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium LED driver Datasheet Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium Dim 100W 1.05A 1-10V 230V I165C LED-based light sources are an excellent solution for highbay industrial

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent Xitanium LED driver Datasheet Xitanium Highbay LED Drivers Dimmable (1-1V) Independent Xitanium Dim 22W 1.5A 1-1V 23V I24C LED-based light sources are an excellent solution for highbay industrial applications.

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

RSTI-EP Slice I/O. Digital Output Module

RSTI-EP Slice I/O. Digital Output Module GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Energy meters Single phase electrical energy meters WM1-6 / WM1M6 Energy meters Single phase electrical energy meters WM1-6 / WM1M6 o Single phase direct connected DIN-rail mounting meter o Class 1 for active energy according to EN 62053-21 and B according to EN 50470-3

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information

Installation and User Guide

Installation and User Guide D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect

More information

LED driver 40W 1050mA 40V s 230V

LED driver 40W 1050mA 40V s 230V Electrical input data minal input voltage 220...240 Vac minal input frequency 47.5...63 Hz minal input current 0.19 minal input power 43 W Power factor 0.96 Total harmonic distortion 10 Efficiency 87,

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

InteliLite MRS17 Click Here to Learn More

InteliLite MRS17 Click Here to Learn More InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

MCX08M2 Programmable controller

MCX08M2 Programmable controller Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

Proven robustness and reliable electronic driver design. Robust design; capable of withstanding harsh outdoor conditions.

Proven robustness and reliable electronic driver design. Robust design; capable of withstanding harsh outdoor conditions. Xitanium LED driver Datasheet Xitanium Outdoor LED Drivers Dimmable (1-10V) Independent Xitanium Dim 250W 0.70A 1-10V 230V I220C LED-based light sources are an excellent solution for outdoor environment.

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

Digital Speed Controller User Manual

Digital Speed Controller User Manual Diesel Engine for Generators Digital Speed Controller User Manual (DSC-1000) Ver_1.0 Doosan Infracore 페이지 1 / 36 Contents 1. Product Overview and General Specification 1.1 Product Information 1.2 Product

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date: Documentation Sixteen Channel Digital Output Module with D-Sub Connector Version: Date: 2.0 2016-08-03 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety

More information

Neon pr. ph/ ORP measurement. Applications. Description

Neon pr. ph/ ORP measurement. Applications. Description Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information