Agilent U2941A Parametric Test Fixture

Size: px
Start display at page:

Download "Agilent U2941A Parametric Test Fixture"

Transcription

1 Agilent U2941A Parametric Test Fixture Operating Guide Agilent Technologies

2 Notices Agilent Technologies, Inc No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Manual Part Number U Edition First Edition, November 1, 2008 Printed in Malaysia Agilent Technologies, Inc Stevens Creek Blvd. Santa Clara, CA USA Warranty The material contained in this document is provided as is, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend U.S. Government Restricted Rights. Software and technical data rights granted to the federal government include only those rights customarily provided to end user customers. Agilent provides this customary commercial license in Software and technical data pursuant to FAR (Technical Data) and (Computer Software) and, for the Department of Defense, DFARS (Technical Data - Commercial Items) and DFARS (Rights in Commercial Computer Software or Computer Software Documentation). Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. II U2941A Operating Guide

3 Safety Symbols The following symbols on the instrument and in the documentation indicate precautions which must be taken to maintain safe operation of the instrument. Direct current (DC) Alternating current (AC) Equipment protected throughout by double insulation or reinforced insulation Off (supply) Both direct and alternating current On (supply) Three-phase alternating current Caution, risk of electric shock Earth (ground) terminal Protective conductor terminal Caution, risk of danger (refer to this manual for specific Warning or Caution information) Caution, hot surface Frame or chassis terminal Out position of a bi-stable push control Equipotentiality In position of a bi-stable push control U2941A Operating Guide III

4 General Safety Information WARNING Do not load the output terminals above the specified current limits. Do not use the device if it appears damaged or defective. Observe all markings on the device before establishing any connection. Do not operate the device in the presence of flammable gases or fumes. Do not install substitute parts or perform any unauthorized modification to the device. CAUTION Applying excessive voltage or overloading the device will cause irreversible damage to the circuitry. Use the device with the cables provided. Repair or service that is not covered in this manual should only be performed by qualified personnel. IV U2941A Operating Guide

5 Environmental Conditions This instrument is designed for indoor use and in an area with low condensation. The table below shows the general environmental requirements for this instrument. Environmental conditions Requirements Operating temperature 0 C to 50 C Operating humidity 20% to 85% RH noncondensing Storage temperature 20 C to 70 C Storage humidity 5% to 90% RH noncondensing U2941A Operating Guide V

6 Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC This instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affixed product label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE directive Annex 1, this instrument is classified as a Monitoring and Control Instrument product. The affixed product label is shown below. Do not dispose in domestic household waste To return this unwanted instrument, contact your nearest Agilent Technologies, or visit: for more information. VI U2941A Operating Guide

7 Contents Introduction 1 Product at a Glance 3 Product outlook (with closed cover) 3 Product outlook (with opened cover) 4 Product dimensions 5 Standard Purchase Items 6 Orderable Items 7 Connection Cables 8 Socket Modules 10 Hardware Installation 12 Attaching the socket module 12 Mounting and wiring the DUT on the socket module 14 Software Installation 18 Hardware requirements 18 Software requirements 18 Installing the Parametric Measurement Manager 19 Product Specifications 20 Maintenance 21 U2941A Operating Guide VII

8 VIII U2941A Operating Guide

9 Introduction The Agilent U2941A parametric test fixture is designed for semiconductor device testing. The U2941A has three input channels and a common ground. You can select different types of socket modules for devices- under- test (DUTs) of various pin configurations. By mounting the suitable socket module on the U2941A, you are able to connect the DUTs to the U2722A USB modular source measure unit and U2751A USB modular switch matrix. You can connect the U2722A directly to the U2941A as shown in the following figure. BNC male outer contact (black wire) BNC male inner contact (red wire) CH1 1 S+ O+ S+ O+ G G O S O S U2722A U2941A U2941A Operating Guide 1

10 You also have the option to connect the U2722A via the U2751A to the U2941A as shown below. U2751A CH1 S+ O+ High Low Row 1 O S U2722A Low High Column 1 High Low Row 2 Column 2 High Low 1 BNC male outer contact (black wire) S+ O+ O S BNC male inner contact (red wire) U2941A For the information on the socket modules, refer to Socket Modules on page 10. To obtain more information on the U2722A and U2751A, refer to the U2722A USB Modular Source Measure Unit User s Guide and U2751A USB Modular Switch Matrix User s and Service Guide respectively. 2 U2941A Operating Guide

11 Product at a Glance Product outlook (with closed cover) Top view Input connectors Common ground connector Front view U2941A Operating Guide 3

12 Rear view Kensington lock Product outlook (with opened cover) Top view Terminals Socket module 4 U2941A Operating Guide

13 Product dimensions Top view 250 mm 53 mm 200 mm Front view 120 mm U2941A Operating Guide 5

14 Standard Purchase Items Verify that you have received the following items with your U2941A. If anything is missing or damaged, please contact the nearest Agilent Sales Office. Assembly Teflon plate 28- pin dual- in- line package socket module 0.1 inch universal socket module inch universal socket module 0.05 inch universal socket module Four pin plug to pin plug cables (black) Four pin plug to pin plug cables (red) Four pin plug to pin plug cables (blue) Four pin plug to miniature clip cables (black) Four pin plug to miniature clip cables (red) Four pin plug to miniature clip cables (blue) Three BNC to two- wire cables, 1 m PCB jumper pins Agilent Parametric Measurement Manager CD (includes installation and operating guides) 6 U2941A Operating Guide

15 Orderable Items Module options Orderable part number Agilent part number Description U2941A-201 U Assembly Teflon plate U2941A-202 U pin dual-in-line package socket module U2941A-203 U inch universal socket module U2941A-204 U inch universal socket module U2941A-205 U inch universal socket module Cable options Orderable part number Agilent part number Description U2941A-101 U Four pin plug to pin plug cables (black) U2941A-102 U Four pin plug to pin plug cables (red) U2941A-103 U Four pin plug to pin plug cables (blue) U2941A-104 U Four pin plug to miniature clip cables (black) U2941A-105 U Four pin plug to miniature clip cables (red) U2941A-106 U Four pin plug to miniature clip cables (blue) U2941A-107 U Three BNC to two-wire cables, 1 m U2941A Operating Guide 7

16 Connection Cables BNC to two- wire cable (U ) 1 m 40 mm 6.4 mm Follow the procedure below to connect the BNC to two- wire cables from the U2722A to the U2941A input connectors. 1 Push the cables through the cable casing. Refer to the U2722A USB Modular Source Measure Unit User s Guide for the details. 2 Insert the black wire ends of the cables into the SENSE connectors of the U2722A. Insert the red wire ends into the OUTPUT connectors. 3 Push the cable casing towards the connector until it firmly envelops the connector. 4 Connect the BNC ends of the cables to the U2941A input connectors. To connect the U2722A via the U2751A to the U2941A, use the U2922A terminal block. Refer to the U2751A USB Modular Switch Matrix User s and Service Guide for details on the U2922A terminal block. 8 U2941A Operating Guide

17 Pin plug to pin plug cable Residual Resistance: 12 mω typical Black: U Red: U Blue: U mm 220 mm 4.5 mm 1 mm 1 mm Pin plug to miniature clip cable Residual Resistance: 12 mω typical Black: U Red: U Blue: U mm 200 mm 40.8 mm 1 mm U2941A Operating Guide 9

18 Socket Modules Assembly Teflon plate (U ) This insulation board has minimal leakage current which is suitable for extremely low current measurements, depending on the specifications of the cables and the U2722A mm 85.6 mm 83.6 mm 28- pin dual- in- line package (U ) This socket module has a 28- pin dual- in- line lever actuated zero insertion force (ZIF) socket mm 85.6 mm 83.6 mm 10 U2941A Operating Guide

19 Universal socket module 0.1 inch pitch: U inch pitch: U inch pitch: U This socket module is used for measurement of virtually any device such as components, DIP IC, CPGA package, or any small- scale circuit mm 85.6 mm 83.6 mm Jumper pin (U ) It is used with the universal socket module. 0.5 mm 8 mm U2941A Operating Guide 11

20 Hardware Installation Attaching the socket module After selecting the appropriate socket module for the DUT, install the socket module to the U2941A. The following figure shows the attachment of a socket module to the U2941A. Black plastic fasteners Socket module Use the following procedure to attach the socket module. NOTE Ensure that no voltage or current is applied to the U2941A when attaching the socket module. 1 Open the lid of the U2941A. 2 Check that the black plastic fasteners of the socket module are unlocked (pulled up). 3 Insert the socket module onto the U2941A. 4 Press the black plastic fasteners down to lock the socket module into place. 12 U2941A Operating Guide

21 Use the following procedure to remove the socket module from the U2941A. NOTE Ensure that no voltage or current is applied to the U2941A when removing the socket module. 1 Open the lid of the U2941A. 2 Remove the connection cables. 3 Pull up the black plastic fasteners on both sides of the socket module. 4 Lift the socket module from the U2941A. NOTE Always unlock the black plastic fasteners when the socket module is not in use. U2941A Operating Guide 13

22 Mounting and wiring the DUT on the socket module You can mount and wire the DUTs as described in the following. Non-Kelvin connections Connect the pin plug to pin plug cables between the Output terminals on the U2941A and the desired terminals on the socket module. Kelvin connections Connect a pin plug to pin plug cable between the Output terminal on the U2941A and the desired terminal on the socket module, and then connect a pin plug to miniature clip cable between the Sense terminal and DUT lead. The U2941A enables usage of the Kelvin connections for a maximum of three U2722A channels. The following figure shows an example of the Kelvin connection for channel 1. Connected to the O terminal of channel 1 Connected to the S+ terminal of channel 1 Connected to the O+ terminal of channel 1 Connected to the S terminal of channel 1 DUT 14 U2941A Operating Guide

23 You may also connect an additional pin plug to pin plug cable between the Sense terminal and the hole of the pin plug connected to the terminal as shown in the following figure. Connected to the S+ terminal Connected to the O terminal Connected to the O+ terminal Connected to the S terminal U2941A Operating Guide 15

24 Connections for a uniquely shaped device If there is no suitable socket module for a uniquely shaped DUT, you can connect the device by using the assembly Teflon plate or universal socket module as described in the following. Assembly Teflon plate Connect the terminals directly to the DUT on the assembly Teflon plate using the pin plug to miniature clip connection cables, as shown in the following figure. Ensure that the DUT is placed on the assembly Teflon plate. Connected to the O terminal Connected to the O+ terminal DUT Assembly Teflon plate 16 U2941A Operating Guide

25 Universal socket module The provided pitch sizes (0.1 inch, inch, and 0.05 inch) offer you the flexibility to mount your DUT on the U2941A. You may either solder the DUT directly or insert an IC holder on the universal socket module. Open the casing of the socket module by removing the screws and use a wire to connect the DUT lead or IC holder lead to the jumper pin which is inserted on the socket module. The jumper pins connection at the bottom layer of the printed circuit board (PCB) is shown in the Bottom view figure. The other end of the jumper pins at the top layer of the PCB allows you to connect the terminals to the jumper pins using the pin plug to miniature clip cables as shown in the Top view figure. Top view Bottom view Pin plug to miniature clips Wires Jumper pins DUT Universal socket module NOTE Do not use the universal socket module for low leakage current measurements (<1 na). U2941A Operating Guide 17

26 Software Installation System requirements The Parametric Measurement Manager extends the capabilities of the U2941A by allowing you to perform various types of measurements efficiently. Before installing the Parametric Measurement Manager, ensure that your PC meets the following minimum system requirements for installation and operation. Hardware requirements Required hardware Processor Operating system Video Browser Available RAM Hard disk space Specification (Minimum) 1.6 GHz Pentium IV or higher One of the following Microsoft Windows versions: Windows XP Professional or Home Edition, Service Pack 1 or later Windows 2000 Professional, Service Pack 4 or later recommended Microsoft Internet Explorer 5.01 or higher (6.0 or higher recommended) 512 MB (1.0 GB or higher recommended) 1.0 GB free disk space at runtime Software requirements Required software Version (Minimum) Agilent IO Libraries Suite Version 15.0 [1] or higher Agilent VEE Runtime version 8.5 [2], patch [2] Agilent Measurement Manager Version 1.6 [3] or higher Microsoft.NET Framework Version 1.1 and 2.0 [1] Available on the Agilent Automation-Ready CD. [2] Bundled with the Agilent Parametric Measurement Manager installer. [3] Bundled with the Agilent U2722A USB Modular Source Measure Unit or Agilent U2751A USB Modular Switch Matrix. 18 U2941A Operating Guide

27 Installing the Parametric Measurement Manager 1 Disconnect any instrument that is connected to your PC and close all other applications on your PC. 2 Insert the Agilent Parametric Measurement Manager CD into your CD- ROM drive. 3 If the installation menu does not appear after a few seconds, go to Start > Run and type <drive>:\ Autorun.exe where <drive> is your CD- ROM drive location. Click OK to begin installation. 4 Click Application on the Agilent Parametric Measurement Manager Installation Menu to begin the installation. 5 Click OK to begin the installation. 6 If you do not have any of the prerequisites installed, the InstallShield Wizard software prerequisite will appear. 7 Click OK to begin the installation of the listed missing prerequisites. 8 Once the above installation has completed, installation of the Parametric Measurement Manager will proceed as normal. 9 The Agilent Parametric Measurement Manager 1.0 InstallShield Wizard dialog will appear. Click Next to begin. 10 Read the License Agreement and select I accept the terms in the License Agreement to proceed. You may click Print to print a hardcopy of the Agilent License Terms for your reference. Click Next to proceed. 11 Fill in the Customer Information Form accordingly, and click Next. 12 Click Next to install to the specified folder or click Change to install to a different folder. 13 Click Install to begin the installation of the Parametric Measurement Manager. 14 Click Finish when the installation has completed. 15 A shortcut to the Parametric Measurement Manager will be created to your desktop. NOTE Refer to the Agilent U2941A Parametric Measurement Manager Application Software Help File for more information on the software features and functions. U2941A Operating Guide 19

28 Product Specifications The following specifications are valid for a temperature of 23 ±5 C and 85% relative humidity. ELECTRICAL SPECIFICATIONS Voltage rating Current rating 60 VDC 1 A ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Operating humidity 20% to 85% RH noncondensing Storage humidity 5% to 90% RH noncondensing Altitude Up to 2000 m PHYSICAL SPECIFICATIONS Dimensions (W D H) Weight Warranty 250 mm 200 mm 120 mm 1.33 kg 3 months 20 U2941A Operating Guide

29 Maintenance To maintain high performance, the U2941A must be kept clean. Oil, perspiration, hair, dust, and dirt will degrade board insulation, which increases leakage current and decreases measurement accuracy. Agilent recommends the following cleaning procedures. Chassis, lid, inner plate, and socket modules 1 Ensure that voltage or current is not applied to the U2941A. 2 Remove all connection cables from the U2941A. 3 Using lint- free paper, gently wipe the chassis, lid, inner plate, and socket module. For any area that will not come clean, dip the lint- free paper into alcohol and wipe the area gently. Connection cables 1 Ensure that voltage or current is not applied to the U2941A. 2 Remove the connection cables from the U2941A. 3 Dip lint- free paper into alcohol and gently wipe the metal contacts of the connection cables. U2941A Operating Guide 21

30 22 U2941A Operating Guide

31 Contact us To obtain service, warranty or technical assistance, contact us at the following phone or fax numbers: United States: (tel) (fax) Canada: (tel) (fax) China: (tel) (fax) Europe: (tel) Japan: (tel) (81) (fax) (81) Korea: (tel) (080) (fax) (080) Latin America: (tel) (305) Taiwan: (tel) (fax) Other Asia Pacific Countries: (tel) (65) (fax) (65) Or visit Agilent World Wide Web at: Product specifications and descriptions in this document are subject to change without notice. Always refer to Agilent web site for the latest revision. Agilent Technologies, Inc., 2008 Printed in Malaysia First Edition, November 1, 2008 U Agilent Technologies

Agilent 16442B. User s Guide. Agilent Technologies

Agilent 16442B. User s Guide. Agilent Technologies Agilent 16442B Test Fixture User s Guide Agilent Technologies Notices Agilent Technologies 2002, 2006 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Errata. Agilent References in this manual. About this manual. Support for your product

Errata. Agilent References in this manual. About this manual. Support for your product Errata Agilent References in this manual NOTICE: This document contains references to Agilent Technologies. Agilent s former Test and Measurement business has become Keysight Technologies. For more information,

More information

Agilent U2941A Parametric Test Fixture

Agilent U2941A Parametric Test Fixture Agilent U2941A Parametric Test Fixture Data Sheet The Agilent U2941A parametric test fixture is designed to complement usage of the Agilent U2722A USB modular source measure unit in the testing of semiconductor

More information

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Agilent E4418/19A Power Meter Hardware Upgrade Kit Agilent E4418/19A Power Meter Hardware Upgrade Kit (E9300 Compatible) Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form

More information

Errata. Agilent References in this manual. About this manual. Support for your product

Errata. Agilent References in this manual. About this manual. Support for your product Errata Agilent References in this manual NOTICE: This document contains references to Agilent Technologies. Agilent s former Test and Measurement business has become Keysight Technologies. For more information,

More information

Agilent OBSAI Protocol Tester

Agilent OBSAI Protocol Tester Agilent OBSAI Protocol Tester Hardware Reference Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent 70612B K18 Switch Matrix

Agilent 70612B K18 Switch Matrix Agilent 70612B K18 Switch Matrix Hardware Reference Manual Agilent Technologies COPYRIGHT 2000 AGILENT TECHNOLOGIES, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR

More information

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide Keysight E5864A Removable Hard Drive for 16850-Series Logic Analyzers Installation Guide Notices Keysight Technologies 2013-2014 No part of this manual may be reproduced in any form or by any means (including

More information

Firmware Guide. Keysight PXIe Chassis Family

Firmware Guide. Keysight PXIe Chassis Family Firmware Guide Keysight PXIe Chassis Family Notices Keysight Technologies, Inc. 2018 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

* * Agilent Power Distribution Unit (PDU) Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The

More information

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies Agilent 34826A BenchLink Data Logger for 34980A Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including

More information

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number Installation Note Removable Hard Disk Drive Upgrade Kit For All PNA Series RF Network Analyzers Network Analyzer Model Number E8356A, E8357A, E8358A E8801A, E8802A, E8803A N3381A, N3382A, N3383A Upgrade

More information

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter Quick Start Guide Keysight GUI Data Logger Software Quick Start Guide 3 Notices Copyright Notice Keysight Technologies

More information

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable Installation Note The 38-pin probe and adapter cable provide a convenient way to connect two Agilent Technologies logic analyzer

More information

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド Agilent 34401A 6½ 桁マルチメータ ユーザーガイド Safety Information General Do not use this product in any manner not specified by the manufacturer. The protective features of this product may be impaired if it is used

More information

Keysight U2722A/U2723A USB Modular Source Measure Units

Keysight U2722A/U2723A USB Modular Source Measure Units Keysight U2722A/U2723A USB Modular Source Measure Units Service Guide Notices Copyright Notice Keysight Technologies 2009-2017 No part of this manual may be reproduced in any form or by any means (including

More information

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means

More information

Agilent Technologies E5385A 100-Pin Probe

Agilent Technologies E5385A 100-Pin Probe Agilent Technologies E5385A 100-Pin Probe Installation Note The Agilent Technologies E5385A 100-pin probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a

More information

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit Operating and Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 1987, 2004, 2008 No part of this manual may be reproduced in any form

More information

Agilent CytoGenomics 2.5

Agilent CytoGenomics 2.5 Agilent CytoGenomics 2.5 Installation and Administration Guide Research Use Only. Not for Diagnostic Procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may

More information

Agilent Gb/s Serial BERT

Agilent Gb/s Serial BERT Agilent 3.125 Gb/s Serial BERT N5980A Programming Guide Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures. Agilent SureCall 3.5 Installation Guide For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies Notices Agilent Technologies, Inc. 2016 No part of this manual may be reproduced

More information

Agilent Connector Plate

Agilent Connector Plate Agilent 16495 Connector Plate Installation Guide Agilent Technologies Notices Agilent Technologies 1997-2005 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Agilent U2722A/U2723A USB Modular Source Measure Unit

Agilent U2722A/U2723A USB Modular Source Measure Unit Agilent U2722A/U2723A USB Modular Source Measure Unit Voltage and current programming and readback Data Sheet The Agilent U2722A/U2723A USB modular source measure unit is more than just a power supply

More information

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number Installation Note Source Attenuators and Bias Tees Upgrade Kit For E8362B/C PNA Series Microwave Network Analyzers Network Analyzer Model Number Upgrade Kit Part Number E8362B/C E8362-60115 Agilent Part

More information

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect Hardware Setup Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form

More information

Test Fixture. User s Guide ABCDE. HP Part No Printed in Japan August Edition 2 E0897

Test Fixture. User s Guide ABCDE. HP Part No Printed in Japan August Edition 2 E0897 Test Fixture User s Guide ABCDE HP Part No. 16442-90000 Printed in Japan August 1998 Edition 2 E0897 Product Warranty Hewlett-Packard warrants Hewlett-Packard hardware, accessories and supplies against

More information

87421/22A Power Supply. Operating and Service Manual

87421/22A Power Supply. Operating and Service Manual 87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to

More information

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies Agilent M9502A and M9505A AXIe Chassis Firmware Revision Firmware Update Guide Agilent Technologies i Notices Agilent Technologies, Inc. 2011, 2012, 2014 No part of this manual may be reproduced in any

More information

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005, 2007 No part of this manual may be reproduced in any form

More information

Agilent InfiniiMax II 1168A/1169A Probes

Agilent InfiniiMax II 1168A/1169A Probes Agilent InfiniiMax II 1168A/1169A Probes Handling Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

DDR/LPDDR Custom Configuration Creator Tool. User s Guide DDR/LPDDR Custom Configuration Creator Tool User s Guide Notices Keysight Technologies 2008-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide Agilent Protocol Analyzer and Jammer for USB Quick Start Guide Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

BenchCel Workstations Software

BenchCel Workstations Software BenchCel Workstations Software User Guide For Research Use Only. Not for use in diagnostic procedures. Original Instructions Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced

More information

Agilent W2100 Antenna Modeling Design System

Agilent W2100 Antenna Modeling Design System Agilent W2100 Antenna Modeling Design System Release Notes Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent Technologies E5339A 38-Pin Low-Voltage Probe Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small

More information

Agilent OpenLAB Data Store Administration. Guide for Administrators

Agilent OpenLAB Data Store Administration. Guide for Administrators Agilent OpenLAB Data Store Administration Guide for Administrators Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Agilent 34959A Breadboard Module

Agilent 34959A Breadboard Module Agilent 34959A Breadboard Module User s Guide Agilent Technologies, Inc. Printed in Malaysia Edition 1 June 2008 E0608 *34980-90059* 34980-90059 Agilent Technologies Notices Agilent Technologies, Inc.

More information

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Agilent Technologies 11667A DC to 18 GHz Power Splitter Agilent Technologies 11667A DC to 18 GHz Power Splitter User's and Service Guide REPRODUCTION AND DISTRIBUTION OF THIS TECHNICAL MANUAL IS AUTHORIZED FOR GOVERNMENT PURPOSES. AgilentTechnologies User's

More information

Keysight E7515A UXM Firmware Update Tool

Keysight E7515A UXM Firmware Update Tool Keysight E7515A UXM Firmware Update Tool For the E7515A UXM Wireless Test Set Installation & User Guide Notices Keysight Technologies, Inc. 2014-2017 No part of this manual may be reproduced in any form

More information

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit Installation Note Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit 85105-60047 Part Number 85105-90023 Printed in USA August 2002 Notice. The information contained

More information

Agilent U2600A Series USB Isolated Digital I/O Devices. Data Sheet

Agilent U2600A Series USB Isolated Digital I/O Devices. Data Sheet Agilent U2600A Series USB Isolated Digital I/O Devices Data Sheet Features Hi-Speed USB 2.0 (480 Mbps) Functions as standalone or modular unit Up to 64 opto-isolated digital I/O lines Up to 1250 V rms

More information

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz Operating and Service Manual Notices Keysight Technologies 1985, 2013, 2014 No part of this manual may be reproduced in any form or by any means

More information

Quick Start/Installation Guide

Quick Start/Installation Guide Agilent Technologies E5850A Time Correlation Fixture Quick Start/Installation Guide The Agilent E5850A time correlation fixture allows you to make time-correlated measurements between a 1680/90 or 16700

More information

Agilent N4880A. Reference Clock Multiplier. User s Guide

Agilent N4880A. Reference Clock Multiplier. User s Guide Agilent N4880A Reference Clock Multiplier User s Guide Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent G2721AA/G2733AA

Agilent G2721AA/G2733AA Agilent G2721AA/G2733AA Spectrum Mill MS Proteomics Workbench Site Preparation Guide Notices Agilent Technologies, Inc. 2001-2012 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight N7015A/16A Type-C Test Kit. User Guide

Keysight N7015A/16A Type-C Test Kit. User Guide Keysight N7015A/16A Type-C Test Kit User Guide Notices Keysight Technologies 2015, 2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit Keysight 11878A 50 Ohm 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1989, 2004, 2013, 2014 No part of this manual may be reproduced in any form or by any means (including

More information

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Agilent U2751A USB Modular Switch Matrix. Data Sheet Agilent U2751A USB Modular Switch Matrix Data Sheet Features and capabilities 32 two-wire crosspoints in 4x8 configuration Minimal crosstalk at up to 45 MHz Bandwidth of 45 MHz without the terminal block

More information

Agilent E5072A Network Analyzer

Agilent E5072A Network Analyzer Agilent E5072A Network Analyzer Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Contents. HP E1586A Rack Mount Terminal Panel User s Manual Contents HP E1586A Rack Mount Terminal Panel User s Manual Description... 5 Connecting to VXIbus Instruments... 5 Interconnect Cables... 5 Terminal Block Connections... 6 Using the Terminal Panel for Reference

More information

Keysight 42941A Impedance Probe Kit

Keysight 42941A Impedance Probe Kit Keysight 42941A Impedance Probe Kit Operation and Service Manual 1 Notices The information contained in this document is subject to change without notice. This document contains proprietary information

More information

86100 Series Infiniium DCA Oscilloscope

86100 Series Infiniium DCA Oscilloscope 86100 Series Infiniium DCA Oscilloscope This manual provides the documentation for the following instruments 86100D 86100C User s Manual Notices Keysight Technologies, Inc. 20xx-2014 No part of this manual

More information

PML 791-RO Low-Z Passive Probe. Instruction Manual

PML 791-RO Low-Z Passive Probe. Instruction Manual PML 791-RO Low-Z Passive Probe Instruction Manual Copyright 2011 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Agilent Softtouch 2.0 Midbus Probe

Agilent Softtouch 2.0 Midbus Probe Agilent Softtouch 2.0 Midbus Probe User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

EVO-TM2A EVO-TM2B Touch Screen Monitor

EVO-TM2A EVO-TM2B Touch Screen Monitor User Manual Revision v1.3 Dec. 2010 EVO-TM2A EVO-TM2B Touch Screen Monitor Copyright 2010 August All Rights Reserved Manual Version 1.3 Part Number: The information contained in this document is subject

More information

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5241A, N5242A, or N5249A Option 419 to Option 423 Upgrade Kit Order Number: N5241AU- 927, N5242AU- 927, and N5249AU-

More information

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables Operations and Installation Manual Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables Notices Keysight Technologies, Inc. 1987-2016 No part of this manual may be reproduced in any form or by any

More information

Agilent E2094M IO Libraries

Agilent E2094M IO Libraries Agilent E2094M IO Libraries Agilent IO Libraries Installation and Configuration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or

More information

Agilent OpenLAB. Data Store. Maintenance Guide

Agilent OpenLAB. Data Store. Maintenance Guide Agilent OpenLAB Data Store Maintenance Guide Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or

More information

Microscan Barcode Reader

Microscan Barcode Reader Microscan Barcode Reader Device Driver Guide For Research Use Only. Not for use in diagnostic procedures. Original Instructions Notices Agilent Technologies, Inc. 2017 No part of this manual may be reproduced

More information

Agilent CSV Export Utility

Agilent CSV Export Utility Agilent CSV Export Utility User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number Installation Note Configurable Test Set Upgrade Kit For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number Upgrade Kit Part Number E8801A, E8802A, E8803A E8801-60103

More information

Agilent TS-8989 PXI Functional Test System

Agilent TS-8989 PXI Functional Test System Agilent TS-8989 PXI Functional Test System Diagnostics User s Guide Agilent Technologies Notices Agilent Technologies Inc. 2014 No part of this manual may be reproduced in any form or by any means (including

More information

Keysight Add Source and Receiver Attenuators Upgrade Kit

Keysight Add Source and Receiver Attenuators Upgrade Kit Keysight Add Source and Receiver Attenuators Upgrade Kit To Upgrade PNA N5221A or N5222A Option 401 to Option 417 Upgrade Kit Order Numbers: N5221AU-417 or N5222AU-417 Keysight Kit Number: N5222-60107

More information

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT. Getting Started with the Agilent Serial BERT N4906B You only need a few minutes to get started with the Serial BERT. This Getting Started Brochure helps you to quickly understand the operating principles

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) Hardware and Software Requirements Agilent Technologies Notices Agilent Technologies, Inc. 2013-2014 No part of this manual may be reproduced in any form

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Agilent TS-5000 Functional Test System

Agilent TS-5000 Functional Test System Agilent TS-5000 Functional Test System E6198B Switch/Load Unit User Manual Agilent Technologies Notices Agilent Technologies, Inc. 2007-2012 No part of this manual may be reproduced in any form or by any

More information

±15 V Current-Limited Power Supply

±15 V Current-Limited Power Supply USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus EU Declaration of Conformity We declare that the accompanying

More information

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 8010 High Power Device Test Fixture Interconnection Reference Guide Model 8010 High Power Device Test Fixture Interconnection Reference Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation. Although

More information

Agilent L4411A 6 ½ Digit Multimeter

Agilent L4411A 6 ½ Digit Multimeter Agilent L4411A 6 ½ Digit Multimeter Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007-2011 No part of this manual may be reproduced in any form or by any means (including

More information

RZ2 BioAmp Processor. Operator s Manual

RZ2 BioAmp Processor. Operator s Manual RZ2 BioAmp Processor Operator s Manual RZ2 BioAmp Processor Operator s Manual Copyright 2008-2013 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or

More information

Keysight Combiner and Mechanical Switches Upgrade Kit

Keysight Combiner and Mechanical Switches Upgrade Kit Keysight Combiner and Mechanical Switches Upgrade Kit To Upgrade PNA-X N5247A/B Option 419 to Option 423 Upgrade Kit Order Number: N5247AU-927 and N5247BU-423 Keysight Kit Number: N5247-60104 Installation

More information

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide Keysight 54006A 6 GHz Passive Divider Probe Kit User s Guide Notices Keysight Technologies, Inc. 1988-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

38 MHz Passive Voltage Probe R&S RT-ZP1X

38 MHz Passive Voltage Probe R&S RT-ZP1X Manual 38 MHz Passive Voltage Probe R&S RT-ZP1X 1333.1370.02 Printed in Germany Test and Measurement 2 Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit our

More information

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Keysight N5191A/93A UXG X-Series Agile Signal Generator Keysight N5191A/93A UXG X-Series Agile Signal Generator Security Features and Document of Volatility Notices Copyright Notice Keysight Technologies 2014-2019 No part of this manual may be reproduced in

More information

Agilent Series Logic Analysis System

Agilent Series Logic Analysis System Agilent 16900-Series Logic Analysis System Quick Start Guide for 16700-Series Users Agilent Technologies Notices Agilent Technologies, Inc. 2003-2004 No part of this manual may be reproduced in any form

More information

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1987-2015 No part of this manual may be reproduced in any form or by any means (including electronic

More information

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

User s Manual Model PBL100 Logic Probe IM E. 4th Edition User s Manual Model 701988 PBL100 Logic Probe 4th Edition Foreword Thank you for purchasing the PBL100 100 MHz Logic Probe (Model 701988). This user s manual describes the functions, operating procedures,

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Wrist Strap and Ground Monitor 773. User s Guide 3M Wrist Strap and Ground Monitor 773 User s Guide Table of Contents Section Page Safety Information... 2 1 Description... 4 Overview... 4 Performance... 4 2 Installation... 5 Supplied Parts... 5 Wire

More information

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System (CDS) Agilent OpenLAB Chromatography Data System (CDS) EZChrom Edition Compatibility Guide for Agilent Instrument Controllers Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual

More information

Agilent 34970A BenchLink Data Logger 3

Agilent 34970A BenchLink Data Logger 3 Agilent 34970A BenchLink Data Logger 3 Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means (including

More information

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply IM E. 5th Edition User s Manual 701934 Power Supply 5th Edition Thank you for purchasing the 701934 Power Supply. This user s manual contains useful information about the functions and operating procedures of the 701934

More information

Agilent TS-8989 PXI Functional Test System

Agilent TS-8989 PXI Functional Test System Agilent TS-8989 PXI Functional Test System Wiring Guide and Hardware Reference Agilent Technologies Notices Agilent Technologies Inc., 2014 No part of this manual may be reproduced in any form or by any

More information

Agilent G6011A Quiet Cover MS

Agilent G6011A Quiet Cover MS Agilent G6011A Quiet Cover MS Service Manual Agilent Technologies Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic storage

More information

Getting Started Guide

Getting Started Guide Agilent Technologies 34980A Multifunction Switch/Measure Unit Getting Started Guide Contents of Your Shipment...1 Front Panel at a Glance...2 Rear Panel at a Glance...3 Supplemental Safety Notices...4

More information

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit Operating and Service Manual Notices Keysight Technologies 1988-2015 No part of this manual may be reproduced in any form or by any means (including electronic

More information

OPERATING AND SERVICE MANUAL SPECIAL SUPPLEMENT

OPERATING AND SERVICE MANUAL SPECIAL SUPPLEMENT OPERATING AND SERVICE MANUAL SPECIAL SUPPLEMENT 11683A OPTION H01 POWER METER RANGE CALIBRATOR 11683-90010 Model Number: 11683A Option H01 Part Number: 11683-90010 Date Printed: June 5, 2012 2 11683A Option

More information

1690-Series Logic Analyzers

1690-Series Logic Analyzers 1690-Series Logic Analyzers Quick Start/Installation Installation 2 Making a measurement 4 Snap to Edge Markers 6 Left-Click Menus 7 Tree Structure Labels 7 Offline Analysis 8 Marker Overview 8 Tool Tips

More information

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Agilent U2751A USB Modular Switch Matrix. Data Sheet Agilent U2751A USB Modular Switch Matrix Data Sheet Features and capabilities 32 two-wire crosspoints in 4x8 configuration Minimal crosstalk at up to 45 MHz Bandwidth of 45 MHz without the terminal block

More information

Agilent 89600B VSA. Software Installation Guide

Agilent 89600B VSA. Software Installation Guide Agilent 89600B VSA Software Installation Guide Notices Agilent Technologies, Inc. 2000-2011 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

Agilent Technologies. PXI 6½ Digit Multimeters. Startup Guide M9181A, M9182A, M9183A. Agilent Technologies

Agilent Technologies. PXI 6½ Digit Multimeters. Startup Guide M9181A, M9182A, M9183A. Agilent Technologies Agilent Technologies PXI 6½ Digit Multimeters M9181A, M9182A, M9183A Startup Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by

More information

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2600B-PM-1 200 V Protection Module with 1 A Clamp Description The Model 2600B-PM-1 200 V Protection

More information