MobileView Junction Box
|
|
- Prudence Clarke
- 6 years ago
- Views:
Transcription
1 Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard G750 MobileView Machine Terminal MT750 The Junction Box can be used either inside or outside a control cabinet based on its IP65 rating. The cables that connect the MobileView terminal to the Junction Box are available as separate catalog numbers. MobileView Connection Cable (Catalog Numbers 2727-MRTxx) connects the MobileView terminal to the Junction Box. The Connection Cable is available in 5, 0, 5, 20 meter (6.4, 32.8, 49.2, 65.6 foot) lengths. MobileView Junction Box Cable (2727-MREY) connects the Junction Box to the MobileView Connection Cable when the Junction Box is mounted inside a cabinet. The cable is 2 meters (6.56 feet) long. Inside... Junction Box Dimensions and Connections... 2 Mounting the Junction Box on a DIN Rail... 3 Connecting the MobileView Terminal to the Junction Box... 5 Junction Box Pinout and Wiring... 6 Specifications... 7
2 2 MobileView Junction Box Junction Box Dimensions and Connections 70 mm (2.76 in) 65 mm (6.50 in) X 0 X mm (5.52 in) SHIELD X X3 SHIELD 7-pin female connector for connection cable Terminal block for power and control lines Terminal block for data lines Cable shield clamp with connection surface for shield of data lines (not used for strain-relief of the cable) ATTENTION The Junction Box and the MobileView terminal meet the safety class III in accordance with EN 63-2 and EN When connecting the MobileView terminal, make sure all voltages connected to the terminal are safety low voltages and isolated from the low voltage supply system by a safety transformer or a similar safety component.
3 MobileView Junction Box 3 Mounting the Junction Box on a DIN Rail Mount the Junction Box on a DIN rail inside the enclosure. Attach DIN Rail Adapter to MobileView Terminal Attach the DIN Rail Adapter to the back of the Junction Box using the screws provided. To install the Junction Box on a DIN rail:. Mount the DIN rail. 2. Hook the top slot of the adapter over the DIN rail. 3. While pressing the Junction Box against the DIN rail, snap the Junction Box into position.
4 4 MobileView Junction Box To remove the Junction Box from the DIN rail:. Place a screwdriver in the adapter latch at the bottom of the Junction Box. 2. Holding the Junction Box, pry downward on the latch until the Junction Box is released from the DIN rail. Mounting Junction Box to a Wall Use the dimensions below for drilling the holes to mount the MobileView Junction Box to a wall. Use the manufacturer s recommendation for hole size based on the screw type and mounting surface. 0.2 mm (0.40i n) 64.8 mm (2.55 in) 40 mm (.58 in) 55 mm (6.0 in)
5 ESC Run KE TOP Error MobileView Junction Box 5 Connecting the MobileView Terminal to the Junction Box Control Cabinet Junction Box MobileView Terminal MobileView Connection Cable Dust Cover maximum wall thickness 5 mm (0.2 in) Power Supply, E-Stop, enabling switch Connector Cutout Junction Box Cable 25 ± 0. mm (.0 ± in) 25 ± 0. mm (.0 ± in) Server 0 Base-T Connection to Ethernet Network Cable Clearance Required minimum distance outside and inside the control cabinet Minimum 30 mm (5.8 in) Minimum 00 mm (3.937 in)
6 6 MobileView Junction Box Junction Box Pinout and Wiring MobileView S9 K MobileView Connection Cable pink black green-brown white-green grey-pink red-blue brown yellow green grey violet MobileView Junction Box Cable K pink black green-brown white-green grey-pink red-blue brown yellow green grey violet Junction Box 24V DC 2 GND_IN 3 E-Stop, circuit, pos.* 4 E-Stop, circuit, neg.* 5 E-Stop, circuit 2, pos.* 6 E-Stop, circuit 2, neg.* 7 Enbl. sw. circ., pos* 8 Enbl. sw. circ., neg* 2 Enbl. sw. circ. 2, pos* 7 Enbl. sw. circ. 2, neg* Not used 9 Not used X V GND ES+ ES- ES2+ ES2- ED+ ED- ED2+ ED2- S4 K blue white orange red blue white orange red K X3 2 RD+ 3 RD- 4 TD+ 5 TD- 6 SHLD * Junction Box connections are for connection to MobileView Guard G750 Terminals only. ATTENTION Refer to the MobileView Guard User Manual (Publication 2727-UM002) for important information on wiring and implementing into machine safety systems.
7 MobileView Junction Box 7 Specifications Electrical Specifications 24V dc Power Supply Environment Specifications Operating Temperature Storage Temperature Relative Humidity (non-condensing) 5% to 95% Vibration resistance (operation) Shock Resistance (operation) Housing Construction Use a 24V dc Safety Extra Low Voltage power supply. Supply Voltage Range: 8V dc to 32V dc Current Consumption: 450mA at 24V dc, 600mA at 8V dc (with MobileView Terminal attached) Peak Inrush Current: 5.6a maximum +0 C to +50 C (+32 F to +22 F) -20 C to +70 C (-4 F to +58 F) 5 f < 9 Hz 7mm 9 f 50 Hz 2g 5g / ms Flammability Class UL 94-V0 Dimensions (W x H x D) NEMA Rating Double-walled ABS housing withstands grease, oil, lubricants, alcohol, etc. 60 mm x 40 mm x 70 mm (6.3 in x 5.5 in x 2.76 in) IP65 ATTENTION The device meets the safety class III in accordance with EN 63-2 and EN The 24V power supply for the equipment must provide appropriate isolation between the safety-extra-low-voltage circuits and dangerous-contact voltage circuits (for example, by safety transformers). The power supply circuit must be protected by a 3.5A fuse. The nominal supply voltage of the MobileView terminal without the connection cable is 24V dc (supply voltage range: 8-32V dc. When planning the power supply, consider the voltage drop in the connection cable. Specifications of the power supply lines in the cable are: Cross section: AWG24 (0.24mm2) Material: zinc-coated copper strand Line resistance: <90 Ohm/km (<45 Ohm/mile)
8 PN () Supersedes Publication XXXX-X.X.X - Month Year Copyright 2004 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
FLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationCompactBlock Guard I/O EtherNet/IP Safety Modules
Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-PS1) 1 2 3 4 5 7 6 Component Identification 1 Supply module 1794-PS1 2 Indicator 3 120/230V ac ground 4 120/230V ac common L2/N connections 5 120/230V ac power
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationINJ-24A Series Quick Installation Guide
INJ-24A Series Quick Installation Guide Moxa High-Power PoE+ Injector Edition 4.1, August 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationMobileView Machine Terminal MT750
MobileView Machine Terminal MT750 2727-M7P20D1P1 2727-M7P20D1Q2 2727-M7P20D1Q3 User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationSecond Generation MobileView Tethered Operator Terminal
Quick Start Original Instructions Second Generation MobileView Tethered Operator Terminal Catalog Numbers 2711T-B10I1N1, 2711T-T10I1N1-TC 2 Second Generation MobileView Tethered Operator Terminal Topic
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the
More informationEngineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O
Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process
More informationM70. Installation Manual. English MAEN843A
MAEN843A 2007-12 M70 Installation Manual English Foreword M70 Installation Manual Foreword The handheld operator panel M70 is a portable operating and display device with rugged design and Windows-CE compatible
More informationInclinometer. 4-20mA and RS232
Inclinometer 4-20mA and RS232 Real size Main Features - Two axis digital inclinometer n - Angle measurement range of +/-5, +/-15 and +/-30, Resolution up to 0.001 - Active linearization and temperaturecompensation
More informationEAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI
EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER MAIN FEATURES Industry standard multiturn absolute encoder for factory automation applications. Optical sensor technology
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationAbsolute encoders - SSI
Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available
More informationIB080QM65VA3 Part Number
Inductive Proximity Switch with increased Switching Distance IB080QM65VA3 Part Number Technical Data Inductive Data Switching Distance 8 mm Correction Factors V2A/CuZn/Al 0,93/0,40/0,36 quasi-flush A/B/C/D
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationPower Supply HARTING pcon
HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSlim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS
HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationIBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description
IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in
More information8 10/100/1000T Industrial Switch. User Manual MS655208(X)
8 10/100/1000T Industrial Switch User Manual MS655208(X) Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel... 5 Top View...
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution
GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More informationfor a perfect electrical installation. The range of rail-mounted terminal blocks
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
More informationPower Supply HARTING pcon
HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationcamera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition
ipf opti-check 1070 53 x 99.5 x 38mm camera sensor operating distance variable C-mount for lenses integrated flash controller short set-up times because of up to 255 check programs with up to 32 feature
More informationFL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.
Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches
More information4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT
4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with
More informationInstallation manual for for Schleifenbauer DPM3
Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation
More informationDigital ac/dc (24V) Input Module
Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge
More informationClassification Enclosure rating Input voltage Type of
Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationStride Industrial Ethernet Switches
8-Port Ethernet Switch with Fiber Port STRIDE Industrial Ethernet Switch with eight 10/100BaseT RJ45 Ethernet ports and one 100BaseFX Fiber optic port (ST type multimode fiber connector for links up to
More informationComponent identification
IO-ATC8 I/O Expansion Module 8 Analog/Thermocouple Inputs The IO-ATC8 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 inputs that
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More information8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual
8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...
More informationDescription of parts Panel mounting Insert mounting without/with Carrier element Plastic housings
- Contents Page Features -... 11.02 Component range -... 11.03 Description of parts... 11.04 Latching parts without/with Strain relief and Panel mounting parts... 11.06 Panel mounting... 11.08 Insert mounting
More informationVL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features
Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationCONTROL PANEL WIRING SPECIFICATIONS
CONTROL PANEL WIRING ISSUE STATUS FIRST REV DESCRIPTION DATE 001 1 ST ISSUE 22/04/2014 002 1 ST AMMENDMENT 10/03/2017 003 2 ND AMMENDMENT 08/09/2017 THIS DOCUMENT IS DESIGNED TO COVER ALL APPLICATIONS,
More informationM12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector
M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45
More informationRK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER
RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH REMOTE ELECTRONICS (ANALOG OUTPUT) Main characteristics Absolute transducer with remote electronics structure Sensor available in three
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationVersion 5 Controls for natural ventilation. WUF 110 / 121 / 150 Actuator interfaces
Version 5 Controls for natural ventilation WUF 110 / 121 / 150 Actuator interfaces 6.05 WUF 121 WUF 110 WUF 150 Application the motor interface is used for individual operation of a ±24V DC actuator from
More informationData sheet C6 A modul 1 port 180 M AP pure white
Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationTime Counters mini "h", DC Version
Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationConnector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors
Connector System for Fluorescent Lighting Fixtures Connectors for In-Line Mounting of Fluorescent Lighting Fixtures Fully Polarized Connectors Luminaire Disconnect Connectors Pluggable Lighting Connectors
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationThe SMART Non-contact Safety Sensor SRF With an innovative diagnostic system
The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire
More informationVL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features
A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.
More informationHypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :
Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationProduct Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications
Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications 2/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with
More informationIEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual
Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
More informationFL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C
16-Port Standard Function Ethernet Switches for Normal and Extreme Environments AUTOMATION Data Sheet 2806_en_C 1 Description PHOENIX CONTACT 2011-06-28 2 Features and Benefits The FL SWITCH SFN(T) 16(15)(14)TX
More informationProduct Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series
PRODUCT NEWS Product Discontinuation Notices July 4, 2011 Presence Detection Sensors No. 2011195E Discontinuation Notice of Safety Laser Scanner Product Discontinuation Safety laser scanner Accessories
More informationProduct Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications
Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications 10/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with
More information1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual
1 10/100TX + 1 100FX w/ 1 PoE Injector Industrial Switch User Manual CE Mark Warning This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user
More informationCommunications & Networking
8-Point Source Input & 8-Point Transistor Sink Output odule () Key features include: Communicate with network 8-point source input and 8-point sink output module Removable terminal blocks Use as remote
More informationApplication Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)
Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationPlug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs
1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector
More informationICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter
ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus
More information10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual
10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1
More information24 Input/8 Output AC Block I/O Module
4 Input/8 Output AC Module Cat. No. 79-4A8 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More informationOil-resistive, Long-range Photoelectric Sensor with Metal Housing
Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in
More informationDelivery. Connection. C. AA+BB Helicoidal cable 2. Radial M12 8p CCW. 3. Radial M23 12p CCW
PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS Programmable incremental optical encoder from 1 to 65.536 pulses per rotation Programmable via USB, without an additional programming
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationXPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Sep 11, 2018 Preventa Safety automation Kit configurable
More informationHC900 Remote Termination Panel (RTP) For Relay Outputs
HC00 Remote Termination Panel (RTP) For Relay Outputs Document Number: --- Effective: //0 Supersedes: //0 Summary The Remote Termination Panel (RTP) provides an easy way to connect the HC00 controller
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More informationTable of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7
User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7
More informationXPSMCMDO Digital output pairs expansion modules with screw term
Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationProduct Information ECN 1324S EQN 1336S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications
Product Information ECN 1324S EQN 1336S Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications 112015 ECN 1324S, EQN 1336S Rotary encoders for absolute position values with
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips
More information4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual
4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
More informationContents. Part no.: MLC500T Safety light curtain transmitter
Part no.: 68000307 MLC500T30-750 Safety light curtain transmitter Figure can vary Contents Technical data Suitable receivers Dimensioned drawings Electrical connection Circuit diagrams Operation and display
More informationOTB1C0DM9LP I/O distributed module OTB - CANopen bus m
Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module
More informationFP-PS-4. Features. Installation
OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply
More informationXPSMCMDI Input expansion module with screw term
Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs
More information