1 Issue 4, August 1997 Installation Guide SpectraComm RLN General DataComm

2 Warning This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to CISR-22 of FCC and international rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. The user is cautioned that any changes or modifications not expressly approved by General DataComm void the user s authority to operate the equipment. This digital apparatus does not exceed Class A limits for radio noise emissions from digital apparatus described in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. Warranty General DataComm warrants that its equipment is free from defects in materials and workmanship. The warranty period is one year from the date of shipment. GDC's sole obligation under its warranty is limited to the repair or replacement of the defective equipment provided it is returned to GDC, transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to accident, misuse, or alterations or repair not made by GDC or authorized by GDC in writing. The foregoing warranty is exclusive and in lieu of all other warranties, express or implied, including but not limited to, warranties of merchantability and fitness for purpose. Trademarks and atents General DataComm, the General DataComm logo and the following are trademarks of General DataComm, Inc in the United States and other countries: ACCULINE, ANALOO, AUTOFRAME, BERT 901, DATACOMM SECURE-AK, DATALOO, DIGIDIAL, ENmacs, FASTRO, FIRST RESONSE, GDC, GDC AEX, GENERAL DATACOMM X-RESS, GEN*NET, GEN*AC, IMAGE*TMS, KILOMUX, LAN*TMS, MEGA*BRIDGE, MEGAMUX, MEGAMUX TMS, MEGANET, MEGASLIT, MEGASWITCH, MEGAVIEW, NETCON, NETSWITCH, NMC, QUIKSHIERS, SERVI-CHECK, SERVI-SNA, WINmacs. ANALOO and DATALOO respectively are protected by U.S. patents 3,655,915 and 3,769,454. All other products or services mentioned in this document are identified by the trademarks, service marks, or product names as designated by the companies who market those products. Inquiries concerning such trademarks should be made directly to those companies. H OpenView is a trademark of the Hewlett-ackard Company. Copyright 1997 General DataComm, Inc. All rights reserved..o. Box 1299, Middlebury, Connecticut U.S.A. This publication and the software it describes contain proprietary and confidential information. No part of this document may be copied, photocopied, reproduced, translated or reduced to any electronic or machine-readable format without prior written permission of General Datacomm, Inc. The information in this document is subject to change without notice. General DataComm assumes no responsibility for any damages arising from the use of this document, including but not limited to, lost revenue, lost data, claims by third parties, or other damages. If you have comments or suggestions concerning this manual, please write to Technical ublication Services or call

3 Table of Contents Chapter 1 System Description Overview System Configurations Chapter 2 Installation Overview Unpacking and Handling Installation Shelf Diagnostics Non-RI Card SpectraComm System Hardware Revisions SpectraComm RI System Hardware Revisions RLN Access Server Configuration for Non-RI SpectraComm systems AT Strings rovided for the SpectraComm RI Systems

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lKUHQGHLQHV*HZLWWHUV,QVWDOOLHUHQ6LHGLH7HOHIRQOHLWXQJHQQLFKWLQ HLQHIHXFKWHQ5DXDXβHUGLH'RVHHQWVSULFKWGHQ9RUVFKULIWHQI U )HXFKWUlXH%HU KUHQ6LHXQLVROLHUWH7HOHIRQOHLWXQJHQRGHU (LQULFKWXQJHQQLFKWDXβHUGLHVHVLQGYR7HOHIRQQHW]JHWUHQQW 9RUVLFKWEHLGHU,QVWDOOLHUXQJRGHUbQGHUXQJYRQ7HOHIRQOHLWXQJHQ $FKWXQJ(VJLEWNHLQHGXUFKGHQ%HQXW]HU]XZDUWHQGH7HLOHL *HUlW:DUWXQJGDUIQXUGXUFKTXDOLIL]LHUWHV3HUVRQDOHUIROJHQ 5HJLVWUDWLRQ6WDWXV 3RUW,' 62& ),& 862&

5 Chapter 1 System Description Overview The SpectraComm RLN (Remote LAN Node) system allows remote users to access central site computer networks that operate using LAN facilities. Remote clients can dial through their Cs using a modem, or ISDN Terminal Adapter (TA), and connect to the central site computer network using the SpectraComm RLN system. The SpectraComm RLN ISDN RI system allows users to access the central site LAN with either a modem or TA by dialing the same phone number. The call type is detected automatically by each channel. The RLN, which consists of a rack of modems and an access server, connects the remote user to the central site LAN and allows access to the same resources as if the user was directly connected to the network. These resources include printers, file servers, application servers, Internet access, news, , and so forth. Individual users dial in to the modem rack, which is connected to the RLN Server C by way of a 26-conductor cable that can extend to 250 feet. The SpectraComm RLN system is made of the following components: SpectraComm RLN shelf (one or two 16-slot chassis) SpectraComm RLN server (C compatible platform with server software) Dual V.34 Modems (up to 32 analog lines per shelf) SC5034 Dual Modem Data Set Emulators (up to 24 T1 or 23 ISDN B-channels per shelf) SC5001 Line Terminating Unit (terminates T1 or ISDN RI line) SC RI Card (provides ISDN D-Channel signaling) Refer to Table 1-1 below for the system components and manuals.

6 1-2 Overview Table 1-1 System Components and Their References Component art Number Manual art Number RLN Server Ethernet S-076M n/a RLN Server Token Ring S-076M n/a RLN Expansion License 076V A n/a RLN Server Software Kit 076V A n/a SpectraComm RLN Shelf 100/120V 010M R SpectraComm RLN Shelf 220/240V 010M R SpectraComm RLN Shelf -48V 010M R SC 5001 LTU R SC5034 Dual Modem Emulator R Dual V.34 Modem R SpectraComm RI Card erforms D-Channel signalling so that the RLN system can communicate over an ISDN rimary Rate (RI) line R Optional Cables Ribbon Cable 029H n/a Ribbon Cable 029H n/a 4-foot Host Controller Cable S-076H n/a 50-foot Host Controller Cable S-076H n/a 100-foot Host Controller Cable S-076H n/a 250-foot Host Controller Cable S-076H n/a The SpectraComm RLN shelf combines a rack of Dual V.34 Modems or SC5034 Dual Modem Data Set Emulators, and a T1 Line interface unit (1 LTU - required for 5034). In addition, the SpectraComm RLN shelf combines up to 32 individual DTE channels into a high speed serial TDM connection to the SpectraComm RLN server. This connection eliminates the need for separate cabling on each modem interface and allows the SpectraComm RLN server to be remotely located. See Figure 1-1, below.

7 System Configurations 1-3 LAN Token Ring or Ethernet entium 100 RLN Server NIC Card SST Card SC or 32 ports Service types: 24 port via T1 32 port via analog lines SC5000 (optional) 24 or 32 ports Figure 1-1 SpectraComm RLN Server System System Configurations Refer to Table 1-2 for RLN Server, System Configurations. Table 1-2 RLN Server System Configurations SC RLN/ETH art/number 32 ort Async 120V 076A ort Async 120V 076A ort Async 220V 076A ort Async 220V 076A T1 120V 076A Dual 2 T1 120V 076A T1 220V 076A Dual 2 T1 220V 076A SC RLN/TR 32 ort Async 120V 076A ort Async 120V 076A

8 1-4 System Configurations Table 1-2 RLN Server System Configurations (Continued) 32 ort Async 220V 076A ort Async 220V 076A T1 120V 076A Dual 2 T1 120V 076A T1 220V 076A Dual 2 T1 220V 076A SC RLN, Shelf Assemblies T1 120V 076M Dual 2 T1 120V 076M ort Async 120V 076M ort Async 120V 076M T1 220V 076M Dual 2 T1 220V 076M ort Async 220V 076M Dual 64 ort Async 220V 076M T M Dual 2 T M ort Async M Dual 64 ort Async M

9 Chapter 2 Installation Overview This chapter guides you through the process of installing and using the SpectraComm RLN System in your communications network. If this is your first experience using these units you may wish to review Chapter 1, System Description, so that you understand the key features and how to install and use the unit in your network. Unpacking and Handling Installation Shelf Inspect the unit for damage. If you find any, notify the shipper immediately. Save the box and packing material so that you can use it to reship the unit, if necessary. All electrical connections are made through the backplane interface. lace the unit in a ventilated area where the ambient temperature does not exceed F (50 0 C). Do not install the unit directly above equipment that generates a large amount of heat (such as power supplies). Refer to your respective product manuals for further installation instructions. See Figure 2-1 for full front view of shelf with installed modems. Figure 2-2 shows a rear view of a typical backpack logic assembly mounted to shelf. Figure 2-3 shows you a shelf-to-shelf connection. To install the SpectraComm Shelf, refer to Operating and Installation Instructions for SpectraComm Shelf, GDC ublication Number 010R ! Be sure to install shelves and power supplies as described in the SpectraComm Shelf manual. Failure to do so may result in overheating and subsequent power supply shutdown.

10 2-2 Installation T1 24 port O W E R S U L Y O W E R S U L Y B L A N K A N E L SC 5034 B L A N K A N E L R I O T I O N C A R D 15 L T U T1 16 Line by Line 32 port O W E R S U L Y O W E R S U LY Dual V Figure 2-1 Front View of Typical Shelf with Installed Modules -48V J52 J32 J48 J31 J47 J30 J46 J29 J45 J28 J44 J27 J43 J26 J42 J25 J41 J24 J40 J23 J39 J22 J38 J21 J37 J20 J36 J19 J35 J18 J34 J17 J33 J51 J50 J16 J15 J14 J13 J12 J11 J10 J9... J8 J7 ower ower On Line Expansion Bus Host Controller J6 J5 J4 J3 J2 J1 Adapter Cable J1 Backpack Logic Assembly Ribbon Cable To RLN Server Cable Figure 2-2 Single SpectraComm RLN Shelf (Rear View)

11 Installation 2-3 Shelf 2-48V J52 J32 J48 J16 J31 J47 J15 J30 J46 J14 J29 J45 J13 J28 J27 J26 J25 J24 J23 J44 J43 J42 J41 J40 J39 J12 J11 J10 J9... J8 J7 ower ower On Line Expansion BusHost Controller J22 J38 J6 J21 J37 J5 J20 J36 J4 J19 J18 J35 J34 J3 J2 J1 Adapter Cable J17 J33 J1 J51 J50 Backpack LogicAssembly Cable Connector (/N S-076H ) from the host controller of one shelf to the expansion bus of the other Ribbon Cable Ferrite EMI Noise Suppressor /N (Install within 1" of connector on 2nd shelf.) Cable Connector (/N 024H ) for shelf-to-shelf connection Shelf 1-48V J52 J32 J48 J16 J31 J47 J15 J30 J46 J14 J29 J45 J13 J28 J27 J26 J25 J24 J23 J44 J43 J42 J41 J40 J39 J12 J11 J10 J9... J8 J7 ower ower On Line Expansion BusHost Controller J22 J38 J6 J21 J37 J5 J20 J36 J4 J19 J18 J35 J34 J3 J2 J1 Adapter Cable J17 J33 J1 J51 J50 Backpack LogicAssembly Ribbon Cable To RLN Server Cable Figure 2-3 Connecting Two SpectraComm RLN Shelves Together (Rear View) for the Non-SpectraComm RI Systems

12 2-4 Installation Connecting Shelf 1 to Server and Shelf 1 to Shelf 2 SpectraComm T1/Dual V.34 Systems Install cable /N S-076H003-xxx from RLN Server to SpectraComm Shelf (See Figure 2-2). To install a second SpectraComm RLN Shelf, use two cables /N S-024H and /N S-H to connect the two shelves to each other. See Figure 2-3, above. SpectraComm RI Systems Install cable /N S-076H003-xxx from RLN Server to SpectraComm Shelf (See Figure 2-2). To install a second SpectraComm RLN Shelf, use two cables /N S-024H and /N S-H to connect the two shelves to each other. This is the same as the non-ri or ISDN system, except you add two ribbon cables: /N 029H and /N 029H See Figure 2-4, below.

13 Installation 2-5 Figure 2-4 Connecting Two SpectraComm RI RLN Shelves Together (Rear View) Expansion BusHost Controller ower On Line ower.. J1 Adapter Cable Ribbon Cable Backpack LogicAssembly. J17 J18 J19 J20 J21 J22 J23 J24 J25 J26 J27 J28 J29 J30 J31 J32 J33 J34 J35 J36 J37 J38 J39 J40 J41 J42 J43 J44 J45 J46 J47 J48 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J15 J16 J50 J51 J52-48V Expansion BusHost Controller ower On Line ower.. J1 Adapter Cable Ribbon Cable Backpack LogicAssembly. J17 J18 J19 J20 J21 J22 J23 J24 J25 J26 J27 J28 J29 J30 J31 J32 J33 J34 J35 J36 J37 J38 J39 J40 J41 J42 J43 J44 J45 J46 J47 J48 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11 J12 J13 J14 J15 J16 J50 J51 J52-48V Cable To RLN Server Cable Connector for shelf-to-shelf (/N 024H ) connection Ferrite EMI Noise Suppressor /N (Install within 1" of connector on 2nd shelf.) Shelf 2 Shelf 1 Cable Connector from the host controller of one shelf to (/N S-076H ) the expansion bus of the other Ribbon Cable (/N 029H ) Ribbon Cable (/N 029H )

14 2-6 Installation Ferrite EMI Noise Suppressor You need to attach a ferrite EMI noise suppressor /N to the expansion cable which connects to the second SpectraComm RLN Shelf for compliance with FCC radio frequency emission requirements. See Figure 2-3 or Figure 2-4. Diagnostics When the On Line indicator on the Backpack Logic Assembly is lit, the system is in operational mode and refer to Attachmate Software, Attachmate Manual for RLN, MGR operation. If the On Line indicator is flashing or not lit, check the server hardware and software. Non-RI Card SpectraComm System Hardware Revisions Dual V.34 must be at a minimum Ca- by way of the TEAM Manager, or must be or higher by way of the ati4 command DSEs must be at a minimum F- by way of the TEAM Manager, or must be or higher by way of the ati4 command LTU must be F- or higher on the firmware label. If it is lower than F-, you can not upgrade the firmware only since you must return the LTU for a change in artwork. SpectraComm RI System Hardware Revisions 5034 DSEs must be at a minimum Firmware Revision of by way of the ati4 command. For the 5001 LTU must be H- or higher on the firmware label. If it is lower than F-, you can not upgrade the firmware only since you must return the LTU for a change in artwork. RI Card must be at a minimum of -- for the firmware by way of the atss command. NOTE For the above SpectraComm RI Systems revisions, the TEAM application and SCM card are not supported. ISDN configuration parameters can be done only by way of the AT command. RLN Access Server Configuration for Non-RI SpectraComm systems NOTE For systems with a SCM and TEAM application, do not use the RLN provided templates for the 5034 and 5001 LTU. For the 5001 LTU slot, configure the RLN port to be down. For the 5034 DSEs, use the Dual V.34 modem template. Configure the Networking options for the 5034 and 5001 LTU, using the TEAM application. T1 Access Lines Using 5001 LTU 1. rovision a T1 circuit for ESF Network Framing and B8ZS for Network Coding whenever possible. 2. Select a Trunk Signaling method, preferably E & M Wink Start 1.

15 Installation Confirm correct slot locations for 5034 DSEs and 5001 LTU as shown in Figure 2-1. Refer to Table 2-8 for assigning slots to ports for Shelves 1 and Using the RLN Management console, or a C Monitor and keyboard attached directly to the RLN Access Server, configure all async ports. 5. The RLN Server (RLN Server Version 4.2 or higher) has templates for different applications, so choose one that best matches the T1 service characteristics (you might have to customize your particular setup, if necessary). 6. After the 5001 LTU has been configured with the AT string, configure the RLN port to be down. Analog Lines Using Dual V.34 Modems 1. Using the RLN Management console, or a C Monitor and keyboard attached directly to the RLN Access Server, configure all async ports. 2. The RLN Server contains the GDC Dual V.34 Modem template. Select this template for all appropriate ports (you might have to customize an AT string for your particular setup, if necessary). NOTE For the best client connections, GDC recommends any GDC Desktop, Fastpro, or Quester modems. Refer to Attachmate RLN Server manual for complete details on configuration and set-up. AT Strings rovided for T1 RLN/SpectraComm Systems (Versions 4.2 and Higher) For T1 lines that have ESF Network Framing, B8ZS Line coding, and Trunk Type E&M Wink Start 1, use the GDC LTU and GDC 5034 templates displayed in Table 2-1, below.

16 2-8 Installation Table 2-1 GDC LTU Auto-Framing B8ZS and 5034 Modem ESF Modes RLN Modem Type GDC LTU Auto Framing B8ZS (server) GDC 5034 Modem ESF Mode (server) AT Command= #b2 #c0 #d0 #e1 #f1 #g0 #i3 #j0 #k0 #10 #m0 #n1 #o1 #q0 #t1 #a1 #x0 #r1:01-24 &f &d2 &s3 \n5 \v2 %b1 *y5034:x1 :y0 :L1 :n1 Options Network timing Concentrator Mode Front anel Enabled Auto Network Frame B8ZS Network Code DS1 Interface Type 0db Manual Network Line Buildout Inhibit Network Ones Density ATT Network FDL Mode Auto Network RCV Range Off-line Network Redundancy Auto Cascade Frame Type B8ZS Cascade Code Off-line Cascade Redundancy Robbed Bit Signal Mode Up Operational Status D-Channel Signalling Normal 24 DS0s Factory default 0 Hang up on DTR Loss Force DSR V.42(LAD)/MN Reliable or MN Mode (or drop call) Connect Message after connection (Microcom Compatible) Make Busy on Loss of DTR Enable Network Configuration commands T1 Time Slots and Default Network arameters (Refer to SC5034 manual) Extended Superframe In Service For T1 lines that have D4 Network Framing, AMI Line Coding, and Trunk Type E&M Wink Start 1, use the GDC LTU and 5034 templates found in Table 2-2, below.

17 Installation 2-9 Table 2-2 GDC LTU Auto-Framing AMI and 5034 Modem D4 Modes RLN Modem Type GDC LTU Auto Framing AMI Mode (server) GDC 5034 Modem D4 Mode (server) AT Command= #b2 #c0 #d0 #e1 #f0 #g0 #i3 #j2 #k0 #10 #m0 #n1 #o0 #q0 #t1 #a1 #x0 #r1:01-24 &f &d2 &s3 \n5 \v2 %b1 *y5034:x1 :y0 :l0 :n1 Options Network timing Concentrator Front anel Enabled Auto Network Frame AMI Network Code DS1 Interface Type 0db Manual Network Line Buildout Max 39 Zeros Network Ones Density ATT Network FDL Mode Auto Network RCV Range Off-line Network Redundancy Auto Cascade Frame Type AMI Cascade Code Off-line Cascade Redundancy Robbed Bit Signal Mode Up Operational Status D-Channel Signalling Normal 24 DS0s Factory default 0 Hang up on DTR Loss Force DSR V.42(LAD)/MN Reliable or MN Mode (or drop call) Connect Message after connection (Microcom Compatible) Make Busy on Loss of DTR Enable Network Configuration commands T1 Time Slots and Default Network arameters (Refer to SC5034 manual) Superframe -D4 In Service AT Strings rovided for Dual V.34 Modem RLN/SpectraComm Systems Table 2-3 gives you a template for the RLN systems with Dual V.34 modems. Table 2-3 RLN Modem Type GDC Dual V.34 Modem AT Command= Options GDC Dual V.34 Modem (server) &f &d2 &s3 \n5 \v2 %b1 Factory Default 0 Hang up on DTR Loss Force DSR V.42(LAD)/MN Reliable or MN Mode (or drop call) Connect Message after connection (Microcom Compatible) Make Busy on Loss of DTR

18 2-10 Installation AT Strings rovided for the SpectraComm RI Systems One-Line SpectraComm RI System 1. rovision a RI access line for B8ZS Network Coding whenever possible. 2. Select the RI card switch type, 4ESS, 5ESS, NT, or NI2 (Refer to Table 2-6). 3. Confirm correct slot locations for 5034 DSEs, RI card (Slot 15), and 5001 LTU as shown in Figure 2-1. Refer to Table 2-8 for assigning slots to ports for Shelves 1 and Configure the 24th DS0 slot in Highway 1 (Com 26 of the RLN) to be out-of-service using the GDC 5034 Out-of-Service (Server) template. 5. Using the RLN Management console, or a C Monitor and keyboard attached directly to the RLN Access Server, configure all async ports. 6. The RLN Server has templates for different applications, so choose one that best matches the RI service characteristics (you might have to customize your particular setup, if necessary). Refer to Table 2-4 and Table After the 5001 LTU has been configured with the AT string, configure the RLN port to be down. Table 2-4 RLN Modem Type GDC LTU ISDN Templates AT Command= Options GDC LTU ISDN Mode Highway 1 (Server) #b2 #c0 #d0 #e1 #f1 #g0 #i3 #j0 #k0 #10 #m0 #n1 #o1 #q0 #t0 #a1 #x1 #r1:01-24 Network timing Concentrator Front anel Enabled Auto Network Frame B8ZS Network Code DS1 Interface Type 0db Manual Network Line Buildout Inhibit Network Ones Density ATT Network FDL Mode Auto Network RCV Range Off-line Network Redundancy Auto Cascade Frame Type B8ZS Cascade Code Off-line Cascade Redundancy Signal Mode None Up Operational Status D-Channel Signalling ISDN Mode 24 DS0s on Highway 1

19 Installation 2-11 Table 2-4 GDC LTU ISDN Templates (Continued) GDC LTU ISDN Mode Highway 2 (Server) #b0 #c0 #d0 #e1 #f1 #g0 #i3 #j0 #k0 #10 #m0 #n1 #o1 #q0 #t0 #a1 #x0 #r2:01-24 Shelf Timing Concentrator Mode Front anel Enabled Auto Network Frame B8ZS Network Code DS1 Interface Type 0db Manual Network Line Buildout Inhibit Network Ones Density ATT Network FDL Mode Auto Network RCV Range Off-line Network Redundancy Auto Cascade Frame Type B8ZS Cascade Code Off-line Cascade Redundancy Signal Mode None Up Operational Status D-Channel Signalling Normal 24 DS0s on Highway 2 Table 2-5 RLN Modem Type GDC 5034 Modem Templates AT Command= Options GDC 5034 Modem ISDN Mode (Server) GDC 5034 Out-of-Service (Server) &f &d2 &s3 \n5 \v2 %b1 *y5034:x1 :y0 :i1 :n1 *y5034:x1 :y0 :n0 Factory default 0 Hang Up on DTR Loss Force DSR V.42(LAD)/MN Reliable or MN Mode (or drop call) Connect Message after connection (Microcom Compatible) Make Busy on Loss of DTR Enable Network Configuration commands T1 Time Slots and Default Network arameters (Refer to SC5034 manual) Signal Method ISDN (Common Channel) In Service Enable Network Configuration commands T1 Time Slots Set for out-of-service Table 2-6 RLN Modem Type GDC RI Templates for One-RI Line AT Command= Options GDC T1 ISDN RI 4ESS (Server) 4ESS DSL1 DHW1 SHW2 &w Switch Type 4ESS Number of Highways Highway 1 contains the D-Channel Second highway set to 2 Store configuration and activate

20 2-12 Installation Table 2-6 GDC RI Templates for One-RI Line (Continued) GDC T1 ISDN RI 5ESS (Server) GDC T1 ISDN RI NI2 (Server) GDC T1 ISDN RI NT (Server) 5ESS DSL1 DHW1 SHW2 &w NI2 DSL1 DHW1 SHW2 &w NT DSL1 DHW1 SHW2 &w Switch Type 5ESS Number of Highways Highway 1 contains the D-Channel Second highway set to 2 Store configuration and activate National ISDN 2 Number of Highways Highway 1 contains the D-Channel Second highway set to 2 Store configuration and activate Switch Type Northern Telecom Number of Highways Highway 1 contains the D-Channel Second highway set to 2 Store configuration and activate Two-Line SpectraComm RI System 1. rovision a RI access line for ESF Network Framing and B8ZS for Network Coding whenever possible. Assign the D-channel signalling to the first RI-line since one D-channel supports both RI lines (47 B-channels). 2. Confirm correct slot locations for 5034 DSEs, RI card (Slot 15), and 5001 LTU as shown in Figure 2-1. Refer to Table 2-8 for assigning slots to ports for Shelves 1 and Attach backplane ribbon cables (/Ns 029H and 029H ).! Turn power off before you install the cables (Figure 2-4). 4. Confirm Shelf Berg jumpers are correct (Refer to Shelf manual). 5. Shelf 1 Berg jumper is in the up position and Shelf 2 Berg jumper is in the down position. The Bergs are located in the shelf backplane J50 location. 6. Using the RLN Management console, or a C Monitor and keyboard attached directly to the RLN Access Server, configure all async ports. 7. Choose the GDC LTU ISDN Mode Highway 1 (Server) for Shelf 1 and GDC LTU ISDN Mode Highway 2 (server) for Shelf 2 (You might have to customize your particular setup, if necessary). 8. Select one of the GDC RI templates for 2-RI lines (Table 2-7). 9. lace the first shelf, 24th DS (Com 26) for out-of-service. Use GDC Out of Service template provided. 10. The RLN Server has templates for different applications, so choose one that best matches the 5034 service characteristics (you might have to customize your particular setup, if necessary). Refer to Table 2-5.

21 Installation After the 5001 LTU has been configured with the AT string, configure the RLN port to be down.! Table 2-7 Do not place the 24th DS of the second shelf in the out-of-service mode. GDC RI Templates for 2 RI Lines RLN Modem Type GDC T1 ISDN 2 RI 4ESS (Server) GDC T1 ISDN 2 RI 5ESS (Server) GDC T1 ISDN 2 RI NI2 (Server) GDC T1 ISDN 2 RI NT (Server) AT Command= 4ESS DSL2 DHW1 SHW2 &w 5ESS DSL2 DHW1 SHW2 &w NI2 DSL2 DHW2 SHW2 &w NT DSL2 DHW2 SHW2 &w Options Switch Type 4ESS Number of highways=2 Highway 1 contains the D-Channel Second highway set to 2 Store configuration and activate Switch Type 5ESS Number of highways=2 Highway 1 contains the D-Channel Second highway set to 2 Store configuration and activate National ISDN 2 Number of highways=2 Highway 2 contains the D-Channel Second highway set to 2 Store configuration and activate Switch Type Northern Telecom Number of highways=2 Highway 2 contains the D-Channel Second highway set to 2 Store configuration and activate Table 2-8 Slot-to-ort Assignments for Shelves 1 and 2 Shelf 1 Shelf 2 Slot Number Modem A Modem B Modem A Modem B 1 Com 1 Com 2 Com 33 Com 34 2 Com 3 Com 4 Com 35 Com 36 3 Com 5 Com 6 Com 37 Com 38 4 Com 7 Com 8 Com 39 Com 40 5 Com 9 Com 10 Com 41 Com 42 6 Com 11 Com 12 Com 43 Com 44

22 2-14 Installation Table 2-8 Slot-to-ort Assignments for Shelves 1 and 2 (Continued) 7 Com 13 Com 14 Com 45 Com 46 8 Com 15 Com 16 Com 47 Com 48 9 Com 17 Com 18 Com 49 Com Com 19 Com 20 Com 51 Com Com 21 Com 22 Com 53 Com Com 23 Com 24 Com 55 Com Com 25 Com 26 Com 57 Com Com 27 Com 28 Com 59 Com Com 29 Com 30 Com 61 Com Com 31 Com 32 Com 63 Com 64 The terms com and port are used interchangeably. NOTE

23 Index A Analog Lines Using Dual V.34 Modems 2-7 AT Strings rovided for Dual V.34 Modem RLN/ SpectraComm Systems 2-9 AT Strings rovided for T1 RLN/SpectraComm Systems (Versions 4.2 and Higher) 2-7 AT Strings rovided for the SpectraComm RI Systems 2-10 C Connecting Shelf 1 to Server and Shelf 1 to Shelf Connecting Two SpectraComm RI RLN Shelves Together (Rear View) 2-5 Connecting Two SpectraComm RLN Shelves Together (Rear View) for the Non-Spectra- Comm RI Systems 2-3 Diagnostics 2-6 D Ferrite EMI Noise Suppressor 2-6 F O One-Line RI Access Lines Using 5001 LTU 2-10 Overview 1-1 R RLN Access Server Configuration for Non-RI SpectraComm systems 2-6 RLN Server System Configurations 1-3 S Shelf 2-1 Single SpectraComm RLN Shelf (Rear View) 2-2 Slot-to-ort Assignments for Shelves 1 and SpectraComm ri System Hardware Revisions 2-6 SpectraComm RLN Server System 1-3 System Components and Their References 1-2 System Configurations 1-3 T T1 Access Lines Using 5001 LTU 2-6 Two-Line RI System 2-12 U Unpacking and Handling 2-1 G GDC LTU Auto-Framing AMI and 5034 Modem D4 Modes 2-9 GDC RI Templates for 2 RI Lines 2-13 Installation 2-1 Installation Requirements 2-1 I N Non-ri Card SpectraComm System Hardware Revisions 2-6

24

25

26 General DataComm

TMS-3000 Controller. Release Notes, Version GTS V2.2.0, Year 2000 Enhancement GDC 036R , Issue 1, November General DataComm, Inc.

TMS-3000 Controller. Release Notes, Version GTS V2.2.0, Year 2000 Enhancement GDC 036R , Issue 1, November General DataComm, Inc. TMS-3000 Controller Release Notes, Version GTS V2.2.0, Year 2000 Enhancement GDC 036R903-22011-01, Issue 1, November 1997 General DataComm, Inc. Warning This equipment generates, uses, and can radiate

More information

Team 7000 V2.1.0 for HPUX/HPOV4

Team 7000 V2.1.0 for HPUX/HPOV4 Team 7000 V2.1.0 for HPUX/HPOV4 Release Notes, Version 2.1.0 087R904-H210-01 General DataComm Warranty General DataComm warrants that its equipment is free from defects in materials and workmanship. The

More information

GDC 058R699-V210 Issue 1, June Installation and Operation. TEAM HDSL for PC. Version General DataComm

GDC 058R699-V210 Issue 1, June Installation and Operation. TEAM HDSL for PC. Version General DataComm Issue 1, June 1997 Installation and Operation TEAM HDSL for PC Version 2.1.0 General DataComm Warning This equipment generates, uses, and can radiate radio frequency energy and if not installed and used

More information

GDC 058R728-V200 Issue 1 - October Operation TEAM for HP OpenView/Unix Version General DataComm

GDC 058R728-V200 Issue 1 - October Operation TEAM for HP OpenView/Unix Version General DataComm Issue 1 - October 1997 Operation TEAM 5002 for HP OpenView/Unix Version 2.0.0 General DataComm Warranty General DataComm warrants that its equipment is free from defects in materials and workmanship. The

More information

GDC 058R720-I Issue 1 - December Operation. TEAM Core Software. for NetView/AIX Version General DataComm

GDC 058R720-I Issue 1 - December Operation. TEAM Core Software. for NetView/AIX Version General DataComm -01 Issue 1 - December 1997 Operation TEAM Core Software for NetView/AIX Version 1.6.0 General DataComm Warranty General DataComm warrants that its equipment is free from defects in materials and workmanship.

More information

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A Installation Guide Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit Issue: 052209 PN: 883884-11L Rev. A ii Copyright Notice 2009, Wyse Technology Inc. All rights reserved. This manual and the software

More information

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved. Monarch 9414 Printer TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved. Each product and program carries a respective written warranty, the only warranty on which the customer

More information

Allworx Tx 92/24 Telephone Expander Installation Guide

Allworx Tx 92/24 Telephone Expander Installation Guide Allworx Tx 92/24 Telephone Expander Installation Guide No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,

More information

2DScan TM Barcode Scanner

2DScan TM Barcode Scanner 2DScan TM Barcode Scanner Quick Start Manual Default Check Version FCC WARNING STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part

More information

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 AUI to 10BASE-FL Transceiver MAY 2003 LE1603A CUSTOMER SUPPORT INFORMATION

More information

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications

TELink FLASH. Model 700a. Installation and Operation Instructions. Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications TELink FLASH Model 700a Installation and Operation Instructions Magic On Hold is a Registered Service Mark and Trademark of Avaya Communications Issue 1, 8/01 Printed in USA FCC Notice WARNING: This equipment

More information

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION JANUARY 199 IC131C RS-3 HS CUSTOER SUPPORT INFORATION Order toll-free in the U.S. hours, A.. onday to midnight Friday: 8-8-BBOX FREE technical support, hours a day, days a week: Call --00 or fax --0 ail

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

User s Guide CPSMM Dual-Slot Master Management Module CPSMM Single-Slot Expansion Management Module

User s Guide CPSMM Dual-Slot Master Management Module CPSMM Single-Slot Expansion Management Module User s Guide - Dual-Slot Master Management Module - Single-Slot Expansion Management Module Dual-Slot Master Single-Slot Expansion Transition Networks Dual-Slot Master Management Module enables network

More information

RS-232/RS-422 Optical Isolator

RS-232/RS-422 Optical Isolator MAY 1998 IC457A-F IC457A-M RS-232/RS-422 Optical Isolator CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours

More information

Four Port RS-232 Serial Interface

Four Port RS-232 Serial Interface JUNE 000 IC1C IC181C Four Port RS-3 Serial Interface CUSTOER SUPPORT INFORATION Order toll-free in the U.S. hours, A.. onday to midnight Friday: 8-8-BBOX FREE technical support, hours a day, days a week:

More information

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) JANUARY 2008 Model# SW1006A FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day,

More information

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500

More information

Dual Port RS-232 Serial Interface

Dual Port RS-232 Serial Interface MARCH 000 IC0C ICC Dual Port RS- Serial Interface CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. hours, A.M. Monday to midnight Friday: --BBOX FREE technical support, hours a day, days a week:

More information

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

FIBER OPTIC A/B/C/D SWITCH (LATCHING) JANUARY 2008 Model# SW1005A FIBER OPTIC A/B/C/D SWITCH (LATCHING) CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical support, 24 hours a day, 7 days

More information

Installer/User Guide

Installer/User Guide Installer/User Guide Avocent Corporation 4991 Corporate Drive Huntsville, Alabama 35805-6201 USA 256-430-4000 (Fax) 256-430-4030 http://www.avocent.com FCC Notification Warning: Changes or modifications

More information

1.0 Description. 2.0 Unpacking. 3.0 Installation

1.0 Description. 2.0 Unpacking. 3.0 Installation ES-H, ES-HA Series Precision Balance Thank you for purchasing the Model ES-H and ES-HA precision balance. Please read all operating instructions carefully before using and note the following items to ensure

More information

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A Doc #: Part #: 07M-A MODEM ELIMINATOR, X.21 (CTS ME-X.21) INSTALLATI AND OPERATIS MANUAL An ISO-9001 Certified Company Copyright 2000 Patton Electronics Co., All Rights Reserved PATT ELECTRICS CO. INSTALLATI

More information

TELink 700 FLASH INSTALLATION AND OPERATION MANUAL

TELink 700 FLASH INSTALLATION AND OPERATION MANUAL TELink 700 FLASH INSTALLATION AND OPERATION MANUAL Attention: A telco line surge protector should be used in series with the line connected to this unit. Please leave this manual with the unit after installation

More information

PC Media Converter, Switching (TP-TX/FX)

PC Media Converter, Switching (TP-TX/FX) April 2006 LH6620C LH6621C LH6622C LH6623C PC Media Converter, Switching (TP-TX/FX) Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500

More information

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis The Transition Networks CPSMC0200-2x0 series dual-slot PointSystem chassis is designed for installation of one or two selectable Transition Networks

More information

Cat. No KT/B. Installation Data

Cat. No KT/B. Installation Data Cat. No. 1784-KT/B Installation Data The 1784-KT/B Communication Interface Module allows personal computers, workstations or terminals to communicate with Allen-Bradley processors and controllers, either

More information

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION SEPTEMBER 1995 MT612A-ST MT612AE-ST T1 Fold (2KM) T1 - Fold PWR LINK CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support,

More information

adynamo Technical Reference Manual PART NUMBER October 2014

adynamo Technical Reference Manual PART NUMBER October 2014 adynamo Technical Reference Manual PART NUMBER 99870002-2.02 October 2014 REGISTERED TO ISO 9001:2008 1710 Apollo Court Seal Beach, CA 90740 Phone: (562) 546-6400 FAX: (562) 546-6301 Technical Support:

More information

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude Start Here The NETGEAR Model DS108 Dual Speed Hub is a network hub that enables users to mix and match 10 and 100 megabits per second (Mbps) devices on the same network. This capability eliminates the

More information

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs VDSL LAN Extender Products LMC5220A (Standalone Set, AC) LMC5221A (Standalone, AC, CO Unit) LMC5222A (Standalone, AC, CPE Unit) LMC5223A (Standalone Set, Multi-Power) LMC5224A (Standalone, Multi-Power,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. AM16904-1 Rev. C pg. 1 of 12 SPECIAL NOTICES The following notices

More information

udynamo Troubleshooting Reference Manual PART NUMBER D October 2014

udynamo Troubleshooting Reference Manual PART NUMBER D October 2014 udynamo Troubleshooting Reference Manual PART NUMBER D99875706-20 October 2014 REGISTERED TO ISO 9001:2008 1710 Apollo Court Seal Beach, CA 90740 Phone: (562) 546-6400 FAX: (562) 546-6301 Technical Support:

More information

CANADIAN D.O.C. WARNING

CANADIAN D.O.C. WARNING Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison Corp. reserves the right to make changes in the product, the programs, and

More information

MCN Monitoring and Control Network Comparator Display System. Host Computer Interface Module HIB Hardware Reference Manual

MCN Monitoring and Control Network Comparator Display System. Host Computer Interface Module HIB Hardware Reference Manual MCN Monitoring and Control Network Comparator Display System Host Computer Interface Module HIB Hardware Reference Manual S2-60427-210 NOTE: This module must be configured before being installed in your

More information

USB USB Data Transfer

USB USB Data Transfer DECEMBER 2000 IC149A-R2 USB USB Data Transfer USB to USB Data Transfer CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support,

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

Octal E&M Module. User Manual. Part Number L1

Octal E&M Module. User Manual. Part Number L1 Octal E&M Module User Manual Part Number 1200313L1 61200313L1-1A August 2000 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 (256) 963-8000 2000ADTRAN, Inc. All Rights Reserved. Printed

More information

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800A Network Interface ControlBus Module allows remote monitoring and diagnostics of the 7800 SERIES

More information

10/100 Autosensing PC Media Converter

10/100 Autosensing PC Media Converter April 2006 LE6610C LE6611C LE6612C LE6613C 10/100 Autosensing PC Media Converter Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500 * Fax

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series ilink by Installation & User Manual ilink Magic On Hold 800.584.4653 Internet Downloadable MP3 Music & Message Series Magic On Hold 720 Brooker Creek Blvd., Ste. 215 Oldsmar, FL 34677 800.584.HOLD (4653)

More information

ADL-100 Operator s Manual

ADL-100 Operator s Manual 040604-510896-(01) ADL-100 Operator s Manual For Use With the Accent Disc Laminator 2004 All rights reserved. Notices: The information in this document is subject to change without notice. NO WARRANTY

More information

Rack Input Module Installation Instructions

Rack Input Module Installation Instructions Rack Input Module Installation Instructions DOC. #560105000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set

More information

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector Installation Guide AVA-2902E/I PCI-to-Fast SCSI Host Adapters PCI SCSI Host Adapter with Internal or External Connector R 1 Installing the Host Adapter and SCSI Device WARNING: Before you start, turn OFF

More information

Verify Package Contents

Verify Package Contents Start Here Instructions in this guide are for users of Windows who are installing the Model EA101 USB Ethernet Adapter. For instructions on installing and verifying the Windows network driver, refer to

More information

Product Installation Guide. SST Ethernet Serial Provider (ESP) PN /D September 2000

Product Installation Guide. SST Ethernet Serial Provider (ESP) PN /D September 2000 e SuperSerial Technology Product Installation Guide SST Ethernet Serial Provider (ESP) PN 0/D September 000 Section - ESP Hardware Installation The Equinox SuperSerial Technology (SST) Ethernet Serial

More information

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION

Personal MiniHub. Personal MiniHub RX LINKPORT #AUI PORT 5 UP LINK PWR JUNE 2001 LE2650A LE2650AE CUSTOMER SUPPORT INFORMATION JUNE 2001 LE2650A LE2650AE 12V 10BASE-T #AUI UP PORT 1 2 3 4 CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

CHS 7Ci. Bluetooth Cordless Barcode Scanner.  Quick Start Guide Quick Start Guide CHS 7Ci Bluetooth Cordless Barcode Scanner www.socketmobile.com PACKAGE CONTENTS Product Information Product label Blue/Green/Red LED Scanner head Trigger button CHS 7Ci Lanyard NiMH

More information

DSX-1 Plug-On Board USER MANUAL. Part Number L L1-1A August L1-1 DSX-1 Plug-On Board User Manual i

DSX-1 Plug-On Board USER MANUAL. Part Number L L1-1A August L1-1 DSX-1 Plug-On Board User Manual i DSX-1 Plug-On Board Part Number 1200114L1 USER MANUAL 61200.114L1-1A August 1995 61200.114L1-1 DSX-1 Plug-On Board User Manual i 901 Explorer Boulevard Huntsville, AL 35806-2807 Phone: (205) 971-8000 Fax:

More information

SpectraComm Quick Reference

SpectraComm Quick Reference SpectraComm Quick Reference Highlights High Density Low Power NEBS 3 Certified Managed Steadfast Security Flexible Introduction General DataComm s SpectraComm family of modems, CSU/DSUs and LAN products

More information

IE-MediaChassis/1. Operation Manual

IE-MediaChassis/1. Operation Manual IE-MediaChassis/1 Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the

More information

International Headquarters

International Headquarters IE-MediaChassis/1 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Website: www.bb-elec.com support@bb-elec.com

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

CrystalLink USB 2.0 CAT5 INSTALLATION AND OPERATIONS MANUAL. Part Number CLK-1U4TP-100M/PE Stancliff Road Phone: (281)

CrystalLink USB 2.0 CAT5 INSTALLATION AND OPERATIONS MANUAL. Part Number CLK-1U4TP-100M/PE Stancliff Road Phone: (281) CrystalLink USB 2.0 CAT5 USB CAT5 Extender INSTALLATION AND OPERATIONS MANUAL Part Number CLK-1U4TP-100M/PE 10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM LIMITED WARRANTY

More information

7800 SERIES S7810B Multi-Drop Switch Module

7800 SERIES S7810B Multi-Drop Switch Module 7800 SERIES S7810B Multi-Drop Switch Module PRODUCT DATA APPLICATION The Honeywell 7800 SERIES is a microprocessor-based integrated burner control for automatically fired gas, oil or combination fuel single-burner

More information

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C Installation Guide for PCC Premier Precision Camera Controller Document 342-1136 Rev. C Contents About this Guide 1 Product Overview 2 Features 2 Unpacking the Camera Controller 3 Installation 4 Don t

More information

MAG-WEDGE READER INSTALLATION AND OPERATION MANUAL

MAG-WEDGE READER INSTALLATION AND OPERATION MANUAL MAG-WEDGE READER INSTALLATION AND OPERATION MANUAL Manual Part Number: 99821608 Rev 5 NOVEMBER 2005 REGISTERED TO ISO 9001:2000 20725 South Annalee Avenue Carson, CA 90746 Phone: (310) 631-8602 FAX: (310)

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

SCSI Fiber Optic Extender

SCSI Fiber Optic Extender Black Box Corporation The Source for Connectivity JUNE 1996 IC495A-R2 SCSI Fiber Optic Extender SCSI FIBER OPTIC EXTENDER LINK ACTIVE BUS ACTIVE LINK ERROR POWER CUSTOMER SUPPORT INFORMATION Call our Technical

More information

Connectivity Peripherals User s Guide. Point 510 Point 1600

Connectivity Peripherals User s Guide. Point 510 Point 1600 Connectivity Peripherals User s Guide Point 510 Point 1600 Connectivity Peripherals User s Guide Point 510 Point 1600 Fujitsu Personal Systems, Inc. has made every effort to ensure the accuracy and completeness

More information

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual Messager USB by Nel-Tech Labs, Inc. Installation & User Manual Index: Introduction... 3 Messager USB Layout Summary... Installation... Message Programming & Operation... Troubleshooting... 4 5 6 6 Warranty

More information

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved. Operator s Handbook Monarch FreshMarx 9417 Food Freshness System TC9417OH Rev. AE 1/2015 2013 Avery Dennison Corp. All rights reserved. Each product and program carries a respective written warranty, the

More information

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules APPLICATION PRODUCT DATA The QS7800B Network Interface ControlBus Module allows remote monitoring and diagnostics

More information

Computertop TV-I. Computertop TV-I SEPTEMBER 1993 AC451A CUSTOMER SUPPORT INFORMATION

Computertop TV-I. Computertop TV-I SEPTEMBER 1993 AC451A CUSTOMER SUPPORT INFORMATION SEPTEMBER 1993 AC451A Computertop TV-I Computertop TV-I CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours

More information

Support for Non-Ultra2 SCSI Devices

Support for Non-Ultra2 SCSI Devices 512030a.qxd 11/24/98 2:08 PM Page 1 INTRODUCTION With the SCSI Card 3950U2, you can connect up to 30 SCSI devices, such as hard disk drives, scanners, CD-ROM drives, and tape drives, to any IBM-compatible

More information

CAUTION: Before installing the Windows or Macintosh operating system, see our knowledge base answer ID 1485 for precautionary procedures.

CAUTION: Before installing the Windows or Macintosh operating system, see our knowledge base answer ID 1485 for precautionary procedures. Quick Start Guide Getting Started Kit Contents USB external drive USB cable AC adapter Quick Install Guide USB External Drive AC Adapter USB Cable Quick Install Guide Compatibility CAUTION: Before installing

More information

INSTALLATION AND OPERATIONS MANUAL

INSTALLATION AND OPERATIONS MANUAL CrystalLink USB 2.0 Fiber USB Fiber Extender INSTALLATION AND OPERATIONS MANUAL Part Number CLK-4U2FM-500M CLK-4U2FS-10KM 10707 Stancliff Road Phone: (281) 933-7673 Houston, Texas 77099 WWW.ROSE.COM LIMITED

More information

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION FEBRUARY 1993 MX330A-C MX330A-D 3174/3274 I-Mux LINK CONTROLLER PORT FIBER OPTIC COPPER POWER TX RX TX RX DATA 0 DATA 1 DATA 2 DATA 3 DATA 3174/3274 I-MUX LINK MUX PORT FIBER OPTIC COPPER POWER TX RX TX

More information

WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100

WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100 3DLABS WILDCAT REALIZM INSTALLATION GUIDE WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100 85-000057-001 (Rev B) Copyright 2005 by 3Dlabs A Creative Company 3Dlabs and Wildcat

More information

User Manual. Monarch Printers AAFES Kit Paxar Americas, Inc. a subsidiary of Avery Dennison Corp. All rights reserved.

User Manual. Monarch Printers AAFES Kit Paxar Americas, Inc. a subsidiary of Avery Dennison Corp. All rights reserved. User Manual Monarch Printers AAFES Kit TC9416AAUM Rev. AC 12/07 2006 Paxar Americas, Inc. a subsidiary of Avery Dennison Corp. All rights reserved. Each product and program carries a respective written

More information

Mini Wireless Barcode Reader Quick Guide

Mini Wireless Barcode Reader Quick Guide Mini Wireless Barcode Reader Quick Guide Full user s manual is available on the enclosed CD. Mini Wireless Barcode Reader Quick Guide P/N: 8002-0028*00 FCC WARNING STATEMENT This equipment has been tested

More information

1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35)

1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35) Doc #: Part #: 07M1205P-A MODEM ELIMINATOR, V.35 1205P (CTS ME-V.35) INSTALLATI AND OPERATIS MANUAL An ISO-9001 Certified Company Copyright 2000 Patton Electronics Co., All Rights Reserved PATT ELECTRICS

More information

IE-iMcV-VDSL2-LANextender. Operation Manual

IE-iMcV-VDSL2-LANextender. Operation Manual IE-iMcV-VDSL2-LANextender Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part

More information

PortServer II. Hardware Installation Guide C

PortServer II. Hardware Installation Guide C PortServer II Hardware Installation Guide 90000073C The Digi logo and PortServer II are trademarks of Digi International. All other brand and product names are trademarks of their respective holders. Digi

More information

Model Bulk Sampling Scale. User s Manual

Model Bulk Sampling Scale. User s Manual Model 7050 Bulk Sampling Scale User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

Owner s Manual. DVI Single Link with Audio Splitter. Models: B A and B A

Owner s Manual. DVI Single Link with Audio Splitter. Models: B A and B A Owner s Manual DVI Single Link with Audio Splitter Models: B116-002A and B116-004A Introduction 2 Mounting Instructions 3 Standard Installation 4 Cascade Installation 5 Troubleshooting 7 Warranty & Product

More information

CANADIAN D.O.C. WARNING

CANADIAN D.O.C. WARNING Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison reserves the right to make changes in the product, the programs, and their

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

Centralized Server Administration (CSA ) Manual

Centralized Server Administration (CSA ) Manual Centralized Server Administration ( ) Manual EDITION ONE P/N 101 1071 000 PUBLICATION HISTORY Edition: Edition One Edition Date: June 1991 Printing Date: First Printing: June 1991 Second Printing: November

More information

Operating Instructions

Operating Instructions 028028 Operating Instructions Monarch 939i Intelligent Keyboard for use with 9416 XL, 9906, ADTP1, and ADTP2 TC0939IOI Rev. AN 5/17 2004 Avery Dennison Corp. All rights reserved. Each product and program

More information

Modem-16 Module. User Manual. Part Number L1

Modem-16 Module. User Manual. Part Number L1 Modem-16 Module User Manual Part Number 1200181L1 61200181L1-1A August 1998 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 (256) 963-8000 1998 ADTRAN, Inc. All Rights Reserved. Printed

More information

Messager USB w/ Night Answer

Messager USB w/ Night Answer Messager USB w/ Night Answer Digital Messaging System Installation & Users Guide Attention! Some USB drives have indicator LEDs - These LEDs may blink slow, fast, or may stay solid during playback. Any

More information

MODEL MT RS-232 INSERTION READER TECHNICAL REFERENCE MANUAL

MODEL MT RS-232 INSERTION READER TECHNICAL REFERENCE MANUAL MODEL MT-215232 RS-232 INSERTION READER TECHNICAL REFERENCE MANUAL Manual Part Number 99821504 Rev 6 APRIL 2003 REGISTERED TO ISO 9001:2000 20725 South Annalee Avenue Carson, CA 90746 Phone: (310) 631-8602

More information

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A

DB9 Microdriver CUSTOMER SUPPORT INFORMATION JULY 1994 ME792A ME793A ME794A JULY 1994 ME792A ME793A ME794A DB9 Microdriver Microdriver S/N CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support,

More information

Instruction Manual. Profile Family CD-ROM. Tektronix, Inc. PO Box 1000 Wilsonville, OR USA (USA and Canada)

Instruction Manual. Profile Family CD-ROM. Tektronix, Inc. PO Box 1000 Wilsonville, OR USA (USA and Canada) Instruction Manual Profile Family CD-ROM Tektronix, Inc. PO Box 1000 Wilsonville, OR 97070-1000 USA 1-800-547-8949 (USA and Canada) 1-503-682-7300 http://www.tektronix.com Copyright Copyright 1998 Tektronix,

More information

Edgeport. USB Expansion Modules. Installation Guide

Edgeport. USB Expansion Modules. Installation Guide Edgeport USB Expansion Modules Installation Guide Revision history 90000403 Revision Date Description J June, 2009 Updated the product CD. K July, 2013 Removed the DoC section. L November, 2013 Updated

More information

Software Manual Easy Setup Utility ios Rev. 1.00

Software Manual Easy Setup Utility ios Rev. 1.00 Software Manual Easy Setup Utility ios Rev. 1.00 http://www.bixolon.com Introduction This manual explains the utilities that can be utilized in ios environments for BIXOLON printer products. It is advisable

More information

imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual

imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual FCC Radio Frequency Interference Statement Class A This equipment has been tested and found to comply with the limits

More information

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual McPC/Giga-MediaLinX (PCI and Low Profile PCI Version) 10/100/1000 Mbps Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for

More information

EiconCard S90. for PCI-Compatible Bus. Installation Guide

EiconCard S90. for PCI-Compatible Bus. Installation Guide EiconCard S90 for PCI-Compatible Bus Installation Guide 203-187-01 First Edition (March 1998) Eicon, EiconCard, and EiconCard S90 are trademarks of Eicon Technology Corporation. Changes are periodically

More information

Installing the ipower 70 Room Camera

Installing the ipower 70 Room Camera Installing the ipower 70 Room Camera Copyright 2000-2002: Polycom, Inc. Polycom, Inc., 4750 Willow Road, Pleasanton, CA 94588 www.polycom.com Polycom and the Polycom logo are registered trademarks of Polycom,

More information

ilink LCD/iLink LCD Wireless Installation & User Manual

ilink LCD/iLink LCD Wireless Installation & User Manual ilink LCD/iLink LCD Wireless Installation & User Manual Index: Introduction... 3 ilink Layout Summary... 4-5 LCD Layout Summary... 6-8 Web Browser... 9 Installation... 10-12 Connectivity Test/Volume Adjustments...

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

Keyboard Display Unit

Keyboard Display Unit Keyboard Display Unit 980010-001 Rev.E Page 1 GENERAL INSTRUCTIONS The Keyboard Display Unit (KDU) is a terminal unit that interfaces with Eltron s LP+, TLP and P2242 Series printers in a stand-alone capacity.

More information

Owner s Manual. Media Converters Models: N SC & N ST

Owner s Manual. Media Converters Models: N SC & N ST 200605219 93-2565 N784 SMC OM.qxd 6/7/2006 3:54 PM Page 1 Warranty Registration Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Media Converters

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N: Mobile UHF Reader Quick Guide For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N: 8012-0064001 FCC WARNING STATEMENT This equipment has been tested

More information