1 Digital Proximity System Opera on and Maintenance Manual The DPS (Digital Proximity System) family consists of two devices, the MX2033 and MX2034. The MX2033 is a conven onal 3-wire driver while the MX2034 is a twowire current loop transmi er. Users can configure either unit to measure peak-to-peak vibra on, gap distance, or rota onal speed. These products are used in conjunc on with a proximity probe and extension cable to measure the vibra on levels, gap distances, or rota onal speed of machinery sha s. Users can also configure the units via a USB cable and configura on so ware REV B
2 TABLE OF CONTENTS 1. General Informa on Safety Terms and Symbols General Safety Summary Overview MX2033 Three-Wire Proximity Driver MX2034 Two-Wire Transmi er For more informa on Configuring a DPS Equipment Required So ware Installa on Connec ng the DPS to a Computer Remove the Base Apply Power Launching the DPS Configura on So ware Main Screen Command Line Op ons Device Informa on Device Communica on Status Configurable Device Se ngs Confirming the Configura on Prin ng a Label Installing the Label Using the MX2034 Buffered Output Verifica on and Calibra on Scale Factor Verifica on Scale Factor Custom Calibra on Current Loop Verifica on (MX2034 only) Troubleshoo ng MX2033 and MX MX2034 Only Performance Graphs Driver/Transmi er Temperature Response MX2030/BN Meter System MX2030/BN Meter System Metrix/BN Meter System Metrix/BN Meter System Phase Delay Trademarks and Copyrights Doc# REV B (April 2015) Page 2 of 42
3 1. GENERAL INFORMATION 1.1 SAFETY TERMS AND SYMBOLS Terms that appear in this manual requiring special a en on include: WARNING: Warning statements iden fy condi ons or prac ces that could result in injury or loss of life. CAUTION: Cau on statements iden fy condi ons or prac ces that could result in damage to the product, loss or corrup on of data, or damage to the environment or other property. NOTE: Notes iden fy material of special interest or importance to the user, not including cau ons or warnings. Symbols that may appear on the product and/or in this manual include: HIGH VOLTAGE PRESENT DANGER or CAUTION PROTECTIVE EARTH FUNCTIONAL GROUND NOTE 1.2 GENERAL SAFETY SUMMARY Review the following safety precau ons to avoid injury and prevent damage to this product or any products connected to it. USE ONLY AS SPECIFIED To avoid poten al hazards, use this product only as specified. Only qualified personnel should perform installa on and uninstalla on procedures. OBSERVE ALL TERMINAL RATINGS To avoid fire or shock hazard, observe all ra ngs and markings on the product. Consult the individual sec ons of this manual for further ra ngs informa on before making connec ons to the product. AVOID EXPOSURE TO CIRCUITRY Do not touch exposed electrical connec ons and components when power is present. DO NOT OPERATE WITH SUSPECT FAILURES If you suspect there is damage to this product, have it inspected by qualified personnel. Doc# REV B (April 2015) Page 3 of 42
4 1.3 RECEIVING, INSPECTING AND HANDLING THE SYSTEM Metrix ships the probe, extension cable, and driver as separate units that the user interconnects at the installa on site. Carefully remove all equipment from the shipping containers and inspect it for shipping damage. If you see shipping damage, file a claim with the carrier and submit a copy to Metrix Instrument Co. Include part numbers and serial numbers on all correspondence. If no damage is apparent and the equipment is not going to be used immediately, return the equipment to the shipping containers and reseal un l ready for use. Store the equipment in an environment that is free from poten ally damaging condi ons such as extreme temperature, excessive humidity, or a corrosive atmosphere. 2. OVERVIEW The Metrix Digital Proximity System module comes in two versions: MX wire proximity driver MX wire, loop powered proximity transmi er A complete DPS system requires a DPS module, a proximity probe, and an extension cable. You can configure the MX2033 and MX2034 modules to operate with the probe and cable combina ons shown in Table 1. Table 1: Probe Configura ons Manufacturer Probe Series System Length Metrix MX mm or 8mm p 5m Metrix MX mm or 8 mm p 9 m Metrix mm or 8 mm p 5 m Metrix mm or 8 mm p 9 m Bently Nevada 3300 or 3300 XL 5 mm or 8 mm p Bently Nevada 3300 or 3300 XL 5 mm or 8 mm p 5 m 9 m Bently Nevada mm or 8 mm p 5 m Bently Nevada mm or 8 mm p 9 m Standard target material is AISI Other materials available upon request. Doc# REV B (April 2015) Page 4 of 42
5 The sec ons below provide more module informa on. 2.1 MX2033 THREE WIRE PROXIMITY DRIVER The MX2033 signal output is propor onal to the distance between the probe p and the target material. The signal output follows API Standard 670 and is compa ble with most con nuous vibra on monitoring systems. The MX2033 uses -24Vdc excita on and provides an output scale factor of 7.87 mv/mm (200mV/mil) for 5 mm and 8mm probes. 2.2 MX2034 TWO WIRE TRANSMITTER The MX2034 provides an ISA standard 4-20 ma signal propor onal to vibra on or axial posi- on for direct connec on to a PLC, DCS, SCADA system, or other instrumenta on without requiring a separate monitor system. The MX2034 is powered by +24 Vdc, supplied within the current loop. The MX2034 is user-programmable to func on as either a radial vibra on transmi er (where the 4-20 ma signal is propor onal to peak-peak vibra on amplitude), or as an axial posi on transmi er (where the 4-20 ma signal is propor onal to average probe gap). For convenience when connec ng to signal analyzers, portable data collectors, and test instrumenta on, the raw vibra on signal is available at a short-circuit protected BNC connector. Refer to sec on 3.6 of this manual for important informa on and cau ons regarding proper use of this connector. 2.3 FOR MORE INFORMATION Refer to these documents for more informa on: MX2030 Digital Proximity Transducer System Datasheet DPS Hazardous Area Installa on Manual DPS Label Kit Manual Doc# REV B (April 2015) Page 5 of 42
6 3. CONFIGURING A DPS This sec on lists the procedure for configuring a DPS: Installing the DPS Configura on So ware Connec ng a DPS to your computer Retrieving the configura ons from the DPS Changing the DPS configura on for probe/cable type Changing the DPS full scale range (MX2034 only) Prin ng DPS labels 3.1 EQUIPMENT REQUIRED You will need the equipment listed below to configure a DPS. Item Computer 24V Power Supply USB Cable Notes With Windows XP or Windows 7 Opera ng System Posi ve or Nega ve. Refer to datasheet for power supply voltage tolerance and DPS current requirements. USB 2.0 A/mini B Labels Avery 6570 Label Overlay Included with the DPS Doc# REV B (April 2015) Page 6 of 42
7 3.2 SOFTWARE INSTALLATION Metrix provides the DPS Configura on and U lity So ware on a USB memory s ck that you request with the DPS (Refer to the DPS datasheet for so ware ordering informa on.) Insert the USB s ck into your computer and open explorer to view the files. Double-click the version for your opera on system according to Table 2 and follow the instruc ons listed on the following pages. T 2: O S. V Opera ng System Windows XP Windows 7 Version DPSUser.exe DPSUser_x64.exe Click Next to con nue Figure 1: So ware Installa on Splash Screen Doc# REV B (April 2015) Page 7 of 42
8 Figure 2 shows the end user license agreement. Click Accept to con nue Figure 2: License Agreement Click Install to begin the installa on Figure 3: Installa on Screen Doc# REV B (April 2015) Page 8 of 42
9 If you are running Windows 7, Windows may present a User Account Control no ce as shown in Figure 4. Click Yes to con nue. Figure 4: Windows 7 User Account Control You may addi onally see a Windows Security no ce as shown in Figure 5. Click Install this driver so ware anyway to con nue. Figure 5: Windows 7 Security Control Doc# REV B (April 2015) Page 9 of 42
10 Click the Finish bu on as shown in Figure 6 to close the installa on process. Figure 6: Installa on Complete Screen Doc# REV B (April 2015) Page 10 of 42
11 3.3 CONNECTING THE DPS TO A COMPUTER Follow these steps to access the DPS USB connector for connec on to a computer REMOVE THE BASE Remove the three screws from the DPS base to access the mini USB connector as shown in Figure 7 and Figure 8. Remove these three screws to remove the base Figure 7: Removing the Base Plug the mini-usb connector into the DPS Plug Figure 8: The USB Plug Plug the USB A connector into an available USB port on your computer. Doc# REV B (April 2015) Page 11 of 42
12 3.3.2 APPLY POWER You must apply 24 Vdc power to the DPS while configuring as shown in Figure 9. Note that you can use either a nega ve or posi ve power supply (Refer to the DPS datasheet for voltage and current requirements.) Powering is the same for either the MX2033 or the MX2034. The MX2034 does not require load resistors when programming. Common +24V -24V Common Figure 9: Powering the DPS NOTE: Install the so ware before connec ng and powering the DPS to ensure the computer finds the correct USB driver 3.4 LAUNCHING THE DPS CONFIGURATION SOFTWARE Launch the DPS Configura on So ware by double-clicking the icon: Doc# REV B (April 2015) Page 12 of 42
13 3.5 MAIN SCREEN The DPS Configura on So ware opens with the main screen shown in Figure 10. Figure 10: The Main Screen COMMAND LINE OPTIONS File Exit the DPS Configura on So ware. Print Labels This opens the label prin ng screen to print updated side labels for their unit. This label contains basic configura on informa on as well as user specific informa on such as machine loca on, etc. Help - Provide descrip ons of the various features of the so ware DEVICE INFORMATION The so ware automa cally retrieves the DPS configura on when launched with a powered up DPS unit connected via a USB cable. If you connect a DPS unit a er launching the program, press the Retrieve bu on to retrieve the configura on. The device informa on shows: Data Last Retrieved: The date and me the displayed configura on was retrieved. Model: DPS part number and dash op ons. Doc# REV B (April 2015) Page 13 of 42
14 Descrip on: Digital Proximity Driver (MX2033) or Digital Proximity Transmi er (MX2034) Serial Number: Device serial number Date of Manufacture: Date the device was manufactured. Firmware Version: Firmware model and revision number Hardware Version: Hardware major.minor revision number Factory Calibra on Date: Date of the last me Metrix calibrated the device Last Configura on Change: Date the configura on was last changed DEVICE COMMUNICATION STATUS Table 3: Device Communica on Status Status Descrip on DPS is connected and communica ng properly DPS is not connected or not communica ng CONFIGURABLE DEVICE SETTINGS You can configure a DPS for: Probe Series Probe Diameter System Length Target Material Measurement (MX2034 only) Range (MX2034 only) 4-20mA Direc on (MX2034 only) Doc# REV B (April 2015) Page 14 of 42
15 1) Select the new configura on parameters from the drop down list 2) Click the Send bu on to send the new configura on to the DPS Figure 11: Configuring by Parameters PROBE SERIES All DPS units support Metrix MX2030, Metrix 10,000 series 7200 compa ble, Bently Nevada 3300, and Bently Nevada 7200 series probes. The DPS also supports one addi onal probe type specified at the me of ordering PROBE DIAMETER The DPS currently supports 5mm and 8mm probe p diameters as part of its standard factory-loaded curve set TARGET MATERIAL DPS units support the standard four probe series listed in sec on calibrated for 4140 steel. The addi onal probe type specified at the me of ordering may be calibrated to a variety of materials. Contact Metrix for informa on on special material calibra ons MEASUREMENT The Measurement field is only ac ve for the MX2034 transmi er model. The MX2034 currently supports two measurements: Radial Vibra on and Axial Posi on RADIAL VIBRATION The MX2034 performs a peak to peak detec on and drives the 4-20 ma output as a percentage of the configured range. Doc# REV B (April 2015) Page 15 of 42
16 AXIAL POSITION The MX2034 low pass filters the measured signal and outputs the axial posi on as a percentage of the configured range RANGE The Range choices are different for Radial Vibra on and Axial Posi on measurements mA DIRECTION The MX2034 allows configura on of upscale or downscale for the 4-20mA output. Upscale means that for the range selected in , 4mA corresponds to bo om of scale and 20mA corresponds to top of scale; downscale reverses these conven ons and means that 20mA corresponds to bo om of scale and 4mA corresponds to top of scale CONFIRMING THE CONFIGURATION A er clicking the Send bu on, you will have the op on to abort the configura on change. Press the Yes bu on to con nue PRINTING A LABEL A er sending a configura on change, the so ware will give you the op on to print a label. You can also print a label later from the main screen by clicking Print Labels and then One Label. Figure 12: Prin ng one label Doc# REV B (April 2015) Page 16 of 42
17 Clicking the Print Label bu on next to the label informa on opens up the Print Label Screen. Use this screen to fill in addi onal informa on you want to record with the DPS. Figure 13: Print Label Screen A er filling in any custom informa on, click the OK bu on. The label print start screen opens. The label print start screen allows you to select the label posi on you want the label prin ng to start at. This template is set for Avery 6570 label sheets of 32 labels (or equivalent). NOTE: User-printed labels should be secured under plas c overlay window. Order Metrix p/n DPS Label Prin ng Kit which contains instruc ons, Avery Labels, and overlays needed for prin ng up to 16 labels. Doc# REV B (April 2015) Page 17 of 42
18 Figure 14: Selec ng the label print start posi on Clicking a label star ng point will open the printer selec on screen. Select the printer and click OK to print. Figure 15: Selec ng the printer INSTALLING THE LABEL Remove the backing from the polycarbonate label and adhere the printed label inside the clear window. A ach both labels to the side of the DPS unit. Refer to DPS Label Kit manual for addi onal details. 3.6 USING THE MX2034 BUFFERED OUTPUT Due to the two wire, loop-powered MX2034 transmi er design, the current loop common floats on top of the voltage developed across the current loop sense resistor. Doc# REV B (April 2015) Page 18 of 42
19 The buffered output common is protected against ground loop currents affec ng the current loop output with a 10kΩ resistance between the buffered output common and the loop common. Metrix recommends using a ground isolated instrument or signal isolator. The meter, oscilloscope or analyzer used to measure the gap voltage or to observe the vibra on signal (DYNAMIC OUTPUT) must have an input impedance of one megohm or greater. The scale factor of the output signal is 200 mv/ mil. Metrix recommends a maximum cable length of 15 (5 m) when connec ng to the buffered output due to noise suscep bility caused by the high input and output impedances. CAUTION: When using the MX2034 BNC connector, exercise special care to prevent ground loops that could alter the 4-20mA output, resul ng in spurious alarms or machine trips. Such ground loops can occur when connec ng to grounded test equipment or mul ple input test equipment. Metrix recommends use only with ungrounded test equipment, such as ba ery-powered portable meters, or grounded test equipment with differen al inputs (i.e., neither side of input connec on is ed to ground). Also, cable lengths between the BNC connector and test equipment should be kept suitably short (5m or less) to prevent unwanted noise. 4. VERIFICATION AND CALIBRATION This sec on describes the steps to verify proper DPS opera on and to custom calibrate your DPS to your specific probe and cable. NOTE: The DPS requires the probe and extension cables be from the configured probe series, combine to the configured system length, and view the configured target material in order to meet system range and accuracy Doc# REV B (April 2015) Page 19 of 42
20 CAUTION: Do not connect test equipment or cables to the driver unless the area has been determined to be non-hazardous 4.1 SCALE FACTOR VERIFICATION Follow these steps in this sec on to verify the voltage output scale factor. The basic procedure is: Obtain the correct target material Assemble the test instruments and equipment Electrically zero the probe Measure the output voltage in fixed gap increments OBTAINING THE TARGET Use a 1.2 inch or larger target with 5 mm or 8 mm probes. Be sure your target material matches the material the DPS calibra on material. To verify the calibra on material, follow the steps listed in Figure 16. 1) Retrieve the DPS configura on 2) Verify the Target Material configura on Figure 16: Verifying the Target Material Configura on Doc# REV B (April 2015) Page 20 of 42
21 ASSEMBLE THE TEST INSTRUMENTS AND EQUIPMENT Verifica on requires these instruments and equipment Spindle micrometer Digital Mul meter Power Supply (-24 Vdc +/- 1Vdc) 10 kohm resistor NOTE: Use the BNC connector on the MX2034 to verify the scale factor. The terminal strip signal pin is not used on the MX2034. Figure 17: MX2033 Scale Factor Valida on Set Up Doc# REV B (April 2015) Page 21 of 42
22 Figure 18: MX2034 Scale Factor Valida on Set Up ELECTRICALLY ZERO THE PROBE Set the probe gap electrically to the start of the measurement range by observing the DC output voltage and adjus ng the probe posi on un l the output is -1 V +/- 0.1 V at 10 mils gap. Set micrometer for 10 mils Move probe un l meter reads -1.0V Figure 19: Se ng Electrical Zero Doc# REV B (April 2015) Page 22 of 42
23 MEASURE THE VOLTAGE IN GAP INCREMENTS Increase the micrometer 10 mil (0.25 mm) increments and fill in the measured SIG Voltage in the table below. Table 4: Verifica on Data Table mils mm SIG Voltage To calculate the Average Scale Factor (ASF), subtract the voltage measured at 10 mils (0.25 mm) from the voltage at 90 mils (2.25 mm)and divide by the full scale range of 80 mils (2 mm) Example: Voltage at 90 mils (2.25 mm) is V Voltage at 10 mils (0.25 mm) is V ASF = (-0.98) - (-17.1)/80 = mv/mil Or ASF = (-0.98) - (-17.1)/2 = 8.06 mv/mm To calculate the Incremental Scale Factor (ISF) at each gap, subtract the SIG voltage measured 10 mils (0.25 mm) below each increment and divide by 10 mils (0.25 mm). Example: Voltage at 40 mils (1.0 mm) is -7.1 V Voltage at 50 mils (1.25 mm) is V ISF = (-9.02) - (-7.1)/10 = -192 mv/mil Or ISF = (-9.02) - (-7.1)/0.25 = mv/mm Doc# REV B (April 2015) Page 23 of 42
24 4.2 SCALE FACTOR CUSTOM CALIBRATION You can easily custom calibrate the DPS for your probe following the procedure in this sec- on. Perform the Scale Factor Verifica on as described in sec on 4.1. NOTE: The custom calibra on process overwrites any previous custom calibra on. Standard Metrix factory calibra ons for MX2030 and m and 9m systems are not affected. Open the DPS so ware and click the bu on. The custom calibra on window opens. Enter the voltages measured at each gap from the Scale Factor Verifica on data. NOTE: Voltages are assumed nega ve. Do not put a - sign in front of each voltage. When complete, click the Generate and Load Lineariza on bu on. The so ware will adjust the DPS lineariza on to match the probe and cable. Doc# REV B (April 2015) Page 24 of 42
25 Fill in the voltages measured at each gap and then click the Generate and Load Lineariza on bu on. Figure 20: Filling in the Custom Calibra on Voltages At comple on, the following dialog box shows. Click OK to finish. Figure 21: Custom Calibra on Successful Comple on If the probe and cable run very far out of specifica on, the DPS may not be able to linearize the curve. In this case, the so ware will show an error message as shown in Figure 22. Doc# REV B (April 2015) Page 25 of 42
26 Figure 22: Custom Calibra on Shortened Curve If this occurs, verify that the voltages you entered were correct. Verify that your system components combine to the correct length. If all is correct, you can choose to accept the shortened curve or hit cancel and use a different probe and cable. In some cases, probes and cables that are far out of specifica on can be brought into specifica on by itera ng the custom calibra on process several mes. NOTE: Metrix does not recommend using the custom calibra on feature to calibrate mismatched systems. Mismatched systems degrade probe and cable temperature performance CURRENT LOOP VERIFICATION MX2034 ONLY Follow the steps in this sec on to verify the current loop output for Posi on or Radial Vibra- on configured DPS units POSITION CONFIGURED UNITS The transmi er current output is linearly propor onal to the average probe gap (posi on) between 4 ma and 20 ma. Use the instruments and equipment shown in Figure 23 to verify a posi on transmi er current output. Doc# REV B (April 2015) Page 26 of 42
27 Figure 23: Current Loop Valida on Set Up At each gap, measure and record the SIG Voltage from the volt meter and the current output measured by the Ammeter. mils mm SIG Voltage Current Use the following equa on to determine the expected current at each gap. Current = 16 * (Gap-Bo om Scale Gap) / (Top Scale Gap-Bo om Scale Gap) + 4mA Doc# REV B (April 2015) Page 27 of 42
28 Example: The configured range is 10 to 90 mils and the current gap is 30 mils. Bo om Scale Gap = 10 mils Top Scale Gap = 90 mils NOTE: Tolerance is ma RADIAL VIBRATION Current = 16 * (30-10) / (90-10) ) +4mA = 8mA The transmi er current output is linearly propor onal to the full scale vibra on range between 4 ma and 20 ma. The following equa on represents the rela onship between the vibra on and the loop current: EXAMPLE: Vibra on = (Current (ma) -4) / 16 * (Full Scale Range) Measured ma Full Scale Vibra on Actual Vibra on < mils, pk-pk Probe Fault mils, pk-pk 0.0 mils, pk-pk mils, pk-pk 2.5 mils, pk-pk mils, pk-pk 5.0 mils, pk-pk Doc# REV B (April 2015) Page 28 of 42
29 5. TROUBLESHOOTING 5.1 MX2033 AND MX2034 Symptom Possible Problems Recommended Ac on SIG stuck near -21V Probe is disconnected (7200 only) Verify that the probe is properly connected and the gap is in the OK region. SIG stuck at -Vt SiG shorted to power Disconnect the SIG line at the DPS and measure the DPS voltage between SIG and COM. If this measures correctly, the short is in the field wiring. SIG stuck 0 < Vout < -0.05V SIG stuck at 0 V Scale Factor is high Probe is shorted Probe is disconnected (MX2030 or 3300) Signal wire disconnected Output shorted to common Power or common disconnected Cable length or probe series is configured incorrectly Verify that the probe is properly connected and the gap is in the OK region. Measure between Vt and COM at the DPS and verify the input power is within the specified range. Disconnect the SIG wire and measure between SIG and COM at the DPS to verify the SIG out voltage. If SIG out is correct, the field wiring is shorted or disconnected at the monitor side. Verify that probe and extension cable are of the same series and have the correct system length. Use the custom calibra on feature to correct the scale factor for the given probe (see sec on 4.2) Scale Factor is low Load impedance is too low Verify that the input impedance of the measuring device is 10 kohms. Scale Factor is low Scale Factor is low Scale factor not adjusted for safety barriers Cable length or probe series is configured incorrectly Verify that the monitoring system was correctly configured for safety barriers. With barriers, the scale factor is 192 V/mil. Verify that probe and extension cable are of the same series and have the correct system length. Use the custom calibra on feature to correct the scale factor for the given probe (see sec on 4.2) Doc# REV B (April 2015) Page 29 of 42
30 5.2 MX2034 ONLY Symptom Possible Problems Recommended Ac on Maximum current below 20 ma Current output stuck < 3.5 ma Current output high or low Loop resistance too large or power supply too low. Probe is disconnected or out of range Incorrect 4 20 Scale selected Verify that total loop resistance does not exceed the maximum per Installa on Manual Verify that the probe is connected and the gap is in the specified OK region. Upload the device informa- on (see Sec on 3.5.2) and verify the configured scale. Doc# REV B (April 2015) Page 30 of 42
31 6. PERFORMANCE GRAPHS 6.1 DRIVER/TRANSMITTER TEMPERATURE RESPONSE Shown with custom calibra on and represent typical performance over temperature, DPS unit only at temperature MX2030/BN METER SYSTEM Figure 24: MX2030 5m System, -35 C to +65 C Doc# REV B (April 2015) Page 31 of 42
32 Figure 25: MX2030 5m System DSL 0 C to 45 C Figure 26: MX2030 5m System DSL -35C to +65 C Doc# REV B (April 2015) Page 32 of 42
33 Figure 27: MX2030 5m System ISF, 0 C to 45 C Figure 28: MX2030 5m System ISF -35 C to + 65 C Doc# REV B (April 2015) Page 33 of 42
34 6.1.2 MX2030/BN METER SYSTEM Figure 29: MX2030 9m System, -35 C to +65 C Figure 30: MX2030 9m System DSL, 0 C to +45 C Doc# REV B (April 2015) Page 34 of 42
35 Figure 31: MX2030 9m System DSL, -35 C to +65 C Figure 32: Mx2030 9m System ISF, 0 C to +45 C Doc# REV B (April 2015) Page 35 of 42
36 Figure 33: MX2030 9m System ISF, -35 C to +65 C METRIX/BN METER SYSTEM Figure 34: m System, -35 C to +65 C Doc# REV B (April 2015) Page 36 of 42
37 Figure 35: m System DSL, 0 C to +45 C Figure 36: m System DSL, -35 C to +65 C Doc# REV B (April 2015) Page 37 of 42
38 Figure 37: m System ISF, 0 C to +45 C Figure 38: m System ISF, -35 C to +65 C Doc# REV B (April 2015) Page 38 of 42
39 6.1.4 METRIX/BN METER SYSTEM Figure 39: m System, -35 C to +65 C Figure 40: m System DSL, 0 C to +45 C Doc# REV B (April 2015) Page 39 of 42
40 Figure 41: m System DSL, -35 C to +65 C Figure 42: m System ISF, 0 C to +45 C Doc# REV B (April 2015) Page 40 of 42
41 Figure 43: m System ISF, -35 C to +65 C 6.2 PHASE DELAY Figure 44 shows the expected phase shi error as the measured frequency increases. Figure 44: Phase Delay vs. Frequency Doc# REV B (April 2015) Page 41 of 42
42 7. TRADEMARKS AND COPYRIGHTS All trademarks, service marks, and/or registered trademarks used in this document belong to Metrix Instrument Company, L.P. except as noted below: Bently Nevada, RAM, and NSv are marks of the General Electric Company in the United States and other countries. Microso, Excel, Windows, and Outlook and their respec ve designs are marks of Microso Corpora on in the United States and other countries. Copyright 2013, Metrix Instrument Company, L.P. All rights reserved. on.com on.com 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: Fax: A er Hours (CST) Technical Assistance: Doc# REV B (April 2015) Page 42 of 42
Digital Proximity System Software Installation Manual
Digital Proximity System Software Installation Manual Doc# 100961 REV A (February 2018) Table of Contents Purpose...2 How to Download DPS 1.35 Software from the Internet...3 The difference between Simulate
More informationDigital Proximity System Installation Manual
Digital Proximity System Installation Manual 1180 The DPS (Digital Proximity System) family consists of two devices, the MX2033 and MX2034. The MX2033 is a conventional 3-wire driver while the MX2034 is
More informationPowerPal Selectable Voltage 3-Amp Breadboard Power Supply (#32133)
Web Store: www.parallax.com Office: (916) 624-8333 Tutorials: learn.parallax.com Educator Hotline: (916) 701-8625 Sales: sales@parallax.com Sales: (888) 512-1024 Tech Support: support@parallax.com Tech Support:
More informationmm and 8 mm PROXIMITY TRANSDUCER SYSTEM
Part number 86130-01 Revision U, November 1999 3300 5 mm and 8 mm PROXIMITY TRANSDUCER SYSTEM MANUAL 3300 5 mm and 8 mm Proximity Transducer System Copyright 1998 Bently Nevada Corporation All Rights Reserved.
More informationMetrix DPS 1.35 Software Overview. January 2018
Metrix DPS 1.35 Software Overview January 2018 Metrix DPS 1.35 Main Points Compatibility Metrix MX8030 is completely compatible with BN 3300XL, it is a direct replacement Every MX8030 probe and cable is
More informationDigital Analy 韜 cs Installa 韜 on and Configura 韜 on
Home > Digital AnalyĀcs > Digital Analy 韜 cs Installa 韜 on and Configura 韜 on Digital Analy 韜 cs Installa 韜 on and Configura 韜 on Introduc 韜 on Digital Analy 韜 cs is an e automate applica 韜 on that assists
More informationBW 2050 Manual. Weltech Interna onal Limited INTRODUCTION
INTRODUCTION Weltech Interna onal Limited The BW 2050 has been designed to give the operator complete flexibility for manual live bird weighing. The BW 2050 is ba ery operated and will weigh for up to
More information440 / 450 Electronic Vibra on Switches Datasheet
440 / 450 Electronic Vibra on Switches Datasheet OVERVIEW Metrix 440 and 450 electronic vibra on switches provide economical, self-contained, single-channel vibra on protec on. The 440 switch is suitable
More informationTeslights Hybrid Lighting Controls B-PLC Solution
Teslights Hybrid Lighting Controls B-PLC Solution Technical Manual, T0115 January 2015 Copyright Teslights, LLC 2014-2015 Contents Contact Informa on 2 Warning 2 Disclaimer 2 1. Overview 3 1.1 PLC Head
More informationSet Up Your Print. Overview. The main interface has five components: 1. 3D Viewer
Set Up Your Print Overview Open Uniz Desktop and click Control Bu on to show the 3D model viewer. The main interface has five components: 1. 3D Viewer https://uniz3d.com/support/supportsetprint/ 1/23 2.
More informationMODEL SW6000 & SM6100 CENELEC INSTRUCTIONS
MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805
More informationRemote Power Management & Monitoring System MODEL: 1RU8126MS USER MANUAL E Lake Mary Blvd. Sanford, FL (407) (800)
Take Control Remote Power Management & Monitoring System MODEL: 1RU8126MS USER MANUAL 2000 E Lake Mary Blvd Sanford, FL 32773 (407) 894-8851 (800) 866-5699 contactus@itscommander.com WWW.ITSCOMMANDER.COM
More information1. Safety Precautions (Read these precautions before use.)
R P5043S/N HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions
More informationUSER MANUAL. for Windows & Mac
Stick Reader SDL 440S USER MANUAL for Windows & Mac Links to mobile apps, printers and weighers. Version 03.10.2016 1 Copyright 2016 Shearwell Data Ltd Table of Contents Ge ng started - Page 3 Ba ery informa
More informationUSER MANUAL. for Windows & Mac. Links to mobile apps, printers and weighers.
Stick Reader SDL 400S USER MANUAL for Windows & Mac Links to mobile apps, printers and weighers. Version 09.10.2017 1Copyright 2017 Shearwell Data Ltd Table of Contents Ge ng started - Page 3 Ba ery informa
More informationDX3309 / DP1009 / DD / DC1009 Series
DX3309 / DP1009 / DD100980 / DC1009 Series FFv Proximity Probe Assembly MNX10071 REV C 11/6/2017 1 CONTENTS Section 1 : Overview... 4 Introduction... 4 Description... 4 Section 2: Probe Details... 5 Proximity
More informationNetworking for Wide Format Printers
Networking for Wide Format Printers Table of Contents Configure PC before RIP Installa on... 1 Verifying Your Network Se ngs for Mac Communica on... 3 Changing Your Network Adapter for Mac Communica on...
More informationUSER MANUAL SES-FA4UB
The Audio Source. USER MANUAL SES-FA4UB 4-Channel Unbalanced RCA Audio Over a Single ST Fiber Extender Kit SESCOM PO Box 720 Mt. Marion, NY 12456 www.sescom.com SES-FA4UB Fiber Extender Kit The SES FA4UB
More informationDIGITAL PROXIMITY SYSTEM (DPS) OVERVIEW. Datasheet. The DPS consists of three elements: a Probe, Extension Cable, and Driver or Transmitter.
OVERVIEW The Metrix Digital Proximity System (DPS) combines the performance of a fully API 670 compliant eddy-current proximity measurement system with the flexibility of digital configurability. For the
More informationCompliance with API Standard 670 the PRO Product Standard for Proximity Probes
Connection Technology Center, Inc. 7939 Rae Boulevard Victor, New York 14564 Toll Free: (800) 999-5290 Phone: (585) 924-5900 Fax: (585) 924-4680 Compliance with API Standard 670 the PRO Product Standard
More informationUSER MANUAL. for Windows & Mac
Stick Reader SDL 400S USER MANUAL for Windows & Mac Links to mobile apps, printers and weighers. Version 01.09.2015 1 Copyright 2015 Shearwell Data Ltd Table of Contents Ge ng started - Page 3 Ba ery informa
More informationREGION: NORTH AMERICA
R U M A REGION: NORTH AMERICA R U M A Chapter Issue Date 1 Introduc on 05/21/2012 2 Install and Upgrade Minimum Hardware Requirements Android Opera ng System and Wi Fi Se ngs Installing Revoquest the First
More informationUSER MANUAL. Batteries to Power Your World!
USER MANUAL Batteries to Power Your World! Table of Contents Please read this manual carefully before using the Freedom CPAP Ba ery for the first me and observe all safety warnings. Package Contents...
More informationSOLAR. User manual of high security level electronic lock. Gebaude Sicherheitstechnik Vertriebs GmbH, Kassel
SOLAR User manual of high security level electronic lock Gebaude Sicherheitstechnik Vertriebs GmbH, 34123 Kassel Wer. 1.1 / 02-2013 Contents General informa on...3 Func ons overview and descrip on...4
More informationDIGITAL PROXIMITY SYSTEM (DPS) OVERVIEW. Datasheet. The DPS consists of three elements: a Probe, Extension Cable, and Driver or Transmitter.
OVERVIEW The Metrix Digital Proximity System (DPS) combines the performance of a fully API 670 compliant eddy-current proximity measurement system with the flexibility of digital configurability. For the
More informationMonitor / 1501 User Manual
Monitor 1302 / 1501 User Manual GeChic Corporation 13F-4, No.367, Gongyi Road, West District, Taichung City 403 Taiwan (R.O.C.) Customer Service: service@gechic.com www.gechic.com Facebook Page : www.facebook.com/gechicen
More informationWORKSWELL WIRIS PRO QUICK START GUIDE. FW Version: Release date: 22 nd March, Revision : 1.2 EN
WORKSWELL WIRIS PRO QUICK START GUIDE FW Version: 1.0.0 Release date: 22 nd March, 2019 Revision : 1.2 EN Standard Package Content Confirm that the package contains the items listed below: WIRIS Pro camera
More informationOPERATOR S MANUAL 9000U ISOLATOR
OPERATOR S MANUAL 9000U ISOLATOR Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79 23287281,
More informationEDTracker Pro Wired. User Guide
EDTracker Pro Wired User Guide ENG Document Issue 1.0 Introduction Thank you for purchasing your EDTracker Pro Wired head tracker. We hope that it becomes an invaluable addi on to your gaming experience
More informationGallagher T12 Reader. Installa on Note. The Gallagher T12 Reader
ATTENTION: This equipment contains components that can be damaged by electrosta c discharge. Ensure both you and the equipment are earthed before beginning any servicing. The The is a smart card proximity
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions
More informationKinetic Switch APP User Manual
Kinetic Switch APP User Manual General Safety Instruc ons Please read this manual thoroughly before first use and keep it in a safe place for future reference. The safety precau ons enclosed herein reduce
More informationBT SIP Trunk CRF User Guide - BT Sales / Originator + Specialist
BT SIP Trunk CRF User Guide - BT Sales / Originator + Specialist The following informa on provides an overview of how to use and complete the SIP Trunk elements of the BT System CRF portal. 1. Introduc
More informationCar Video Recorder. RoadRunner 535W. User Manual
Car Video Recorder About this user manual This user manual is specially designed to detail the device s func ons and features. - Please read this manual before using the device to ensure safe and proper
More information3500/45 Position Monitor
3500/45 Position Monitor Bently Nevada Asset Condition Monitoring Description The 3500/45 Position Monitor is a 4-channel monitor that accepts input from proximity transducers, Rotary Position Transducers
More informationRemote Ticket Entry. System/User Requirements
North Carolina 811, Inc. 2300 West Meadowview Rd Suite 227 Greensboro, North Carolina 27407 336.855.5760 Remote Ticket Entry An internet based cket entry system, Remote Ticket Entry (RTE), allows excavators
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationNova-Pro 100 TABLE OF CONTENTS: Safeguards and Precautions
Safeguards and Precautions Nova-Pro 100 LED Stroboscope / Laser Tachometer 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com Website:
More informationThis Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.
This Datasheet for the IC660BBA026 Block 24/48Vdc Analog Current Source 6 Inputs http://www.cimtecautomation.com/parts/p-14421-ic660bba026.aspx Provides the wiring diagrams and installation guidelines
More informationIDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration
More informationQ. How do I start using Mānoa Guardian? A. Go to the App Store or Google Play on your mobile device and download the app. Search for Rave Guardian.
How it Works Q: Why use? A. is designed to allow users quick and easy contact with UH Mānoa Department of Public Safety (DPS) officers, and has addi onal features for increasing safety on campus. Using,
More informationEXERCISE 2: GETTING STARTED WITH FUSION
Exercise Objec ves In this exercise, you ll be using the fully prepared example data to explore the basics of FUSION. Prerequisites Successful comple on of Exercise 1 (Download and Install FUSION and the
More informationETHOS Auto Ranging Digital Multimeter
ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double
More informationINSTALLATION INSTRUCTIONS
www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous
More informationPC PRIVACY SHIELD. User Manual. PC Privacy Shield
PC PRIVACY SHIELD User Manual Table of Contents Welcome...3 Compa bility...3 Installa on and First Scan...5 Registra on...7 Status Screen...8 Ac ve Cleaning...9 Features Bar...9 Scan and Clean...10 User
More informationPrinted Circuit Board Assembly Analysis / 1
Printed Circuit Board Assembly Analysis Introduction DFM Concurrent Costing The first step in the manufacture of the printed circuit board assembly is the fabrica on of the bare circuit board, o en called
More informationDescription. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System
R Specifications and Ordering Information 9200, 74712, 47633 Seismoprobe Velocity Transducer System Description Bently Nevada Seismoprobe Velocity Transducer systems are designed to measure absolute (relative
More informationOBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More information3500/45E Position Monitor
3500/45E Position Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/45E Position Monitor is a 4-channel monitor that accepts input from proximity transducers, Rotary Position Transducers
More informationIsolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.
More informationAUTOMATION. Operator s Manual MND. Modbus Network Display. DOC Rev. A1, 5/14
AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual MND Modbus Network Display DOC. 9003708 Rev. A1, 5/14 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com MND
More informationWilcoxon Research P702B/P702BF-1 operating guide Power unit/amplifier for piezoelectric transducers with internal amplifiers
Wilcoxon Research P702B/P702BF-1 operating guide Power unit/amplifier for piezoelectric transducers with internal amplifiers Caution: This manual should be read carefully before installation. Meggitt Sensing
More informationSIRE Solution Suite. Better Outcomes. Active Review Administration and User Manual. A Publication Of
Active Review Administration and User Manual SIRE Solution Suite An Official Manual of SIRE Technologies Document and Legislative Management Software Version 6.3 A Publication Of Better Outcomes. 2 SIRE
More informationOPERATING INSTRUCTION. Pen-Type Digital Multimeter
OPERATING INSTRUCTION Pen-Type Digital Multimeter International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationI/O SIGNAL CONDITIONER
Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT
More informationVM2800 & VM3800 VIBRACHECK METERS Installation Manual
VM2800 & VM3800 VIBRACHECK METERS Installation Manual OVERVIEW The economical and compact Vibra-Check Vibration Meter is an ideal tool for obtaining spot measurements of machinery vibration. All three
More informationVMS Co., Ltd. VMS Reliability Systems - Korea
VMS Co., Ltd VMS Reliability Systems - Korea Room 1106, QB Centum Bldg, 90, Centum Jungang-ro, Haeundae-gu, Busan, Korea TEL +82 51 782 2323 FAX +82 51 782 0808 E-MAIIL admin@vmsco.co.kr www.vmsco.co.kr
More informationThis Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs
This Datasheet for the IC660BBA104 Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs http://www.qualitrol.com/shop/p-14425-ic660bba104.aspx Provides the wiring diagrams and installation guidelines
More informationOPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd
OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123 Product: High Voltage AC Test Set Type: P123 Bicotest High Voltage Products Ltd Hellesdon Park Road, Drayton High Road, Norwich NR6 5DR United Kingdom Phone
More informationNSR-N43. Navigation mirror. User manual
NSR-N43 Navigation mirror User manual Table of contents Chapter one: Product introduction....................... 1 Main feature........................................ 1 Specification........................................
More informationThis 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 SST7000 SST7100 Speed Switch / Transmitter Installation and Operation Manual Rev. C P/N145F-13112 PCO 00009270
More information991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring
991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring Description The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors
More informationUSB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43
USB COMMUNICATIONS INTERFACE LOOP LINK 5909 DK Side 1 Contents 5 9 0 9 L o o p L i n k U S B C o m m u n i c a t i o n s I n t e r f a c e N o. 5 9 0 9 V 1 0 1 - I N ( 1 0 0 7 ) F r o m s e r. n o. 0 4
More informationMT8050iE series. Installation Instruction (1) (2)
MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup
More informationDFM Concurrent Costing
Die Casting Analysis Start a new analysis For the purposes of this tutorial we will es mate the cost per part of manufacturing 200,000 of the disk drive casings shown here: front The material is to be
More information3500/77M Recip Cylinder Pressure Monitor
3500/77M Recip Cylinder Pressure Monitor Bently Nevada Asset Condition Monitoring Description The 3500/77M Recip Cylinder Pressure Monitor is a 4-channel monitor that accepts input from Bently Nevada approved
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More informationD115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors
D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More information3700 SERIES USER MANUAL
SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with
More informationRiso Comcolor Series
Riso Comcolor Series Ge ng Started Guide No. 1 Ini al Setup Administrator Func ons Administrator Setup Default Se ngs User Names and Passwords Setup IC Card Control System Configura on Riso (UK) Limited
More informationProximity Vibration / Position / Phase Reference Transmitters
Proximity Vibration / Position / Phase Reference Transmitters Seismic Vibration Transmitters kmo turbo GmbH Friedrichstr. 59 88045 Friedrichshafen Germany Phone: +49 7541 95289-0 Fax: +49 7541 95289-20
More informationS Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME
Reclosers Form 4C Microprocessor-Based Recloser Control Analog Current Metering Accessory KME4-82-1, KME4-82-2 Installation and Operation Instructions Service Information S280-77-8 Figure 1. Kyle Form
More informationTC100 Precision Thermocouple Calibrator
TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6
More informationDM3058/DM3058E Digital Multimeter
Quick Guide RIGOL Publication number QGA03109-1110 Feb. 2014 DM3058/DM3058E Digital Multimeter 2008 RIGOL Technologies, Inc. All Rights Reserved Copyright 2008 RIGOL Technologies, Inc. All Rights Reserved.
More informationFluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.
Power Quality Analyzer EN June 2005 2001-2005 Fluke Corporation, All rights reserved. Printed in The Netherlands. All product names are trademarks of their respective companies. PLACING ORDERS AND GETTING
More informationIsolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated, Voltage or Current Input 7B30 FEATURES Interfaces, amplifies and filters unipolar and bipolar millivolt and voltage inputs. Provides a protected precision output of either +1 V to +5 V or 0 V
More informationMARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals
Martindale Electric will carry out routine calibration (on a chargeable basis) if the instrument is returned, carriage paid, to the address on the final page of this document. Alternatively, a chargeable
More information9200, Seismoprobe* Velocity Transducers
9200, 74712 Seismoprobe* Velocity Transducers Product Datasheet Bently Nevada* Asset Condition Monitoring Description Bently Nevada* Seismoprobe Velocity Transducer Systems are designed to measure absolute
More informationSmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs
MAN0969-02 PAGE 1 Mix577/977 Module ` SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs 1 SPECIFICATIONS Analog Inputs High Resolution Steady State Current 120mA @ 24v
More informationCVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-3K-KIT 3 kv Bias Tee Kit Description The CVU-3K-KIT Bias Tee Kit consists of three bias tees for
More informationTLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions
xx ZZZ TLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions www.tektronix.com *P077059110* 077-0591-10 Copyright Tektronix. All rights reserved. Licensed software products
More informationModel INSTRUCTION MANUAL DIGITAL MULTIMETER
Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT
More informationBOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION
QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,
More informationL1.4. LED Studio Light OPERATING INSTRUCTIONS
L1.4 LED Studio Light OPERATING INSTRUCTIONS 580 MAYER STREET, BUILDING #7, PA 15017 USA PHONE 1.412.206.0106 WWW.BRIGHTLINES.COM 2015 BRIGHTLINE, L.P. Safety WARNING: To avoid possible damage to the driver,
More informationDS1000B Series Digital Oscilloscope
Quick Guide RIGOL Publication number QGA04114-1110 Feb. 2014 DS1000B Series Digital Oscilloscope DS1074B, DS1104B, DS1204B All Rights Reserved Copyright All Rights Reserved. RIGOL products are protected
More informationIsolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage
More informationDINB100-SA-KIT Standalone Biometric Kit
DINB100-SA DINRTT DINB100-SA-KIT Standalone Biometric Kit User Manual v.b3 Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING...
More information991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring
991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring Description The 991 Thrust Transmitter is intended primarily for the original equipment manufacturers (OEMs) of centrifugal air compressors
More informationThis Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.
This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.cimtecautomation.com/parts/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0
More informationNT1003 Controller/Receiver
CONTROLLERS, RECEIVERS & SWITCHES NT1003 Controller/Receiver Accepts up to 20 fobs Suitable for motors with loading up to 300w Deadman on/off func on Shock proof relays ideal for Tubular Motors Industry
More informationModel 3750 Multifunction I/O Card
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Model 3750 Multifunction I/O Card Connection Instructions and Specifications Introduction This instruction
More information3300 XL 8mm & mm Proximity Transducer System
Installation Manual Bently Nevada* Asset Condition Monitoring 3300 XL 8mm & 3300 5mm Proximity Transducer System Part Number 4078-0 Rev. V (08/5) 3300 XL 8mm & 3300 5mm Proximity Transducer System 999-205
More informationThis Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.
This Datasheet for the IC0BBA00 Block /8Vdc Analog Inputs / Outputs. http://www.qualitrol.com/shop/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0 module.
More informationTETRIS 2500 High Impedance Active Probe. Instruction Manual
TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications
More informationSeedSense 2017 So ware Release Notes
SeedSense 2017 So ware Release Notes 1. System Wide Changes 1.1 Updated the opera ng system on Gen2 20/20 displays 1.2 Added a 6 item mode to the home screen 1.3 Changed the default se ng to the Display
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationP344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31
P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual January 2018 - Rev 1.31 P344 MIPI D-PHY Probe IMPORTANT SAFETY and USEAGE INFORMATION Please review the following safety precautions to
More information