1 istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers to RM ports and to the direct connect Wiegand ports. It shows how to wire supervised inputs and dry contact relay outputs. System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general purpose board running Windows CE. The GCM has two PCMCIA slots for an internal modem, a second network interface card, or a compact flash card. There is an LCD panel to display current status and to be used when running built in diagnostics. There is a panel of batteries that are used to retain the data memory in the event of a power fail. Access Control Modules (ACM) A special purpose access control board that communicates with the GCM and provides inputs, outputs, and readers. It is possible to interface Wiegand signaling and ABA (magnetic) signaling devices. The istar Pro GCM can interface to one or two ACM modules. Optional 12 VDC@ 5A Power Supply. 1
2 Power POWER This section describes the power requirements for the istar Pro. AC Power The istar Pro input power rating is VAC, 2.3A max, Hz. The system current draw is or 1.1A 47-63Hz. To connect the AC power: 1. Route the conduit for the wiring from AC main power to the knockout closest to the power supply in the enclosure. 2. Place a ferrite core on the AC power cable, inside the enclosure. Use the hot wire (brown/black) and neutral wire (white/blue) to wrap the ferrite with three wire turns. 3. Connect the Hot wire (either Black or Brown) to the L connector next to the power supply. Connect the Neutral wire (either White or Blue) to the N connector. Connect the Ground (Green or Green/Yellow) to the G connector. NOTE If the unit does not have a power supply, route the external +12 VDC to the GCM and the ACMs. 2
3 Power Batteries Use NiMH (Nickel Metal Hydride) batteries - AA size. Minimum 1800 milli-amp hours. Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. istar Pro batteries are packaged separately and should be installed in the battery backup sockets at the bottom of the GCM. The unit is stored and shipped with the batteries disconnected so they will not be drained while in storage. Connect the batteries as shown in the GCM diagram that follows. If the batteries are installed with the power off, the reset switch (S5) must be pressed after power is applied. It is acceptable to install the batteries with the power on. If the batteries are installed with the power on, it is not necessary to press the reset switch. NOTE The batteries provide power to retain the volatile memory (clearances, activity, etc.) data in the event of a power failure. The batteries do not supply enough power for istar Pro normal operations. 3
4 GCM General Control Module GCM GENERAL CONTROL MODULE The diagram below shows all of th GCM components referred to in this guide. For more detailed information see the component map on the door and the complete istar document. Network Connection Connect a CAT 5 RJ45 cable to J4. If the other end of the cable is connected to a hub or switch, it must be straight through. If it is connected directly to a NIC card on the server, it must be a crossover. LED2 indicates the Ethernet Link signal and LED1 displays the Receive Data signal. 4
5 GCM General Control Module Dialup Connection 1. Connect P6 to the istar modem as shown in Table 1. TABLE 1. DB25-to-P6 Pin Connections Modem DB25 Pin Modem DB25 Signal istar P6 Pin istar P6 Signal 2 Tx 1 Tx 4 RTS 2 RTS 5 CTS 3 CTS 3 Rx 4 Rx 7 GND 5 GND 2. Connect the host modem to a COM Port. 3. Set the COM Port to 57,600 baud, 8, None, 1, Hardware Flow Control. 4. Configure the RAS login information using ICU.exe 5. Configure the C CURE 800 Server to accept RAS connections. 6. Configure the controller and cluster using ICU and the C CURE 800. Serial Connection 1. Connect P6 to the Server COM Port as shown in Table 2. TABLE 2. DB9-to-P6 Pin Connections COM Port DB9 Pin COM Port DB9 Signal istar P6 Pin istar P6 Signal 2 Rx 1 Tx 8 CTS 2 RTS 7 and 1 RTS and CD 3 CTS 3 Tx 4 Rx 5 GND 5 GND 2. Set the COM Port to 57,600 baud, 8, None, 1, Hardware Flow Control. 3. Configure the RAS login information using ICU.exe 4. Configure the C CURE 800 Server to accept RAS connections. 5. Configure the controller and cluster using ICU and the C CURE
6 GCM General Control Module Diagnostic session A diagnostic session can be run either through ICU or with a terminal session through P5. Turn on the diagnostic information settings using either ICU or the HTML connection to the istar. Note that the diagnostic information causes overhead and should not be left on during normal operation. 1. Connect P5 to a COM port on a PC. Use a straight through DB9F to DB9F cable. 2. Set the COM port to 115,200 baud, 8, None, 1, Hardware Flow Control 3. Start a terminal session using an emulator such as HyperTerminal. LED s LED4 indicates power and shines through an opening in the door. LED2 displays the Ethernet Link signal on P6. LED1 displays the Receive Data signal on P6. Switches DIP Switch S2 is factory set for RS232 on P6. Do not change. DIP Switch S1 is factory set for RS232 on P6. Do not change. DIP Switch S4 is used to control diagnostics, clear memory and to display card reads in hexadecimal. See the istar Pro door map for more detailed information about running diagnostics. To display hexadecimal card reads on the LCD Panel set switch 4-8 on. The Reset Switch, S5, will cause the GCM computer to reboot. Pressing S5 will also clear memory, including configured readers, inputs and outputs. As long as there is a connection to the host these objects will be immediately downloaded again to the memory. If switch 4-2 is on when S5 is pressed, the unit will be reset to factory default. This means that all of the connection data, such as the IP address will be cleared in addition to the memory. In this case the unit will have to be totally configured again using ICU.exe. If you want to clear memory and reboot the unit, use the following procedure: 1. Set switch 4-2 on. 2. Press S5 and wait 10 seconds. 3. Set switch 4-2 to off. 4. Press S5 and observe the LCD panel. The unit will reboot but it will have to be completely re-configured. 6
7 GCM General Control Module LCD Panel The LCD panel will display various status information, such as the connection status to the host, and various diagnostic functions. If the LCD panel is difficult to read, adjust the contrast using the potentiometer at the upper right section of the GCM. MAC Address When configuring an istar Controller, it is necessary to supply the MAC address of the NIC card that is connected. The MAC address for the on-board 10BaseT NIC is displayed on a sticker just left of the Power LED. If a PCMCIA NIC card is used, the MAC address will be provided by the manufacturer. 7
8 ACM Access Control Module(s) ACM ACCESS CONTROL MODULE(S) There can be either one or two ACM (Access Control Modules) in an istar Pro. The ACM provides the Readers, Inputs and Outputs that are used in access control. The following diagram shows all of the components, switches, and LED s described in this guide. RM4 Readers Either Wiegand or ABA (magnetic) read heads are connected to RM-4s, RM-4Es, or MRM s. The RM s are interfaced using STAR1 through STAR8. Pin 1 for each connector is shown in the preceding diagram. It is important that the ports are wired as follows: TABLE 3. Pin Signals and Colors STARx Pin Signal Color VDC Red 2 Tx+ / Rx+ White 3 Tx- / Rx- Green 4 GND Black 8
9 ACM Access Control Module(s) The STARn connectors are not keyed so it is possible to reverse the signals. If the ground connector (pin 4) is connected to +12 VDC (pin 1), damage to the power supply or the RM could result. The reader number is not determined by the Port that it is plugged into. It is determined by a hexadecimal switch on the RM. Whichever reader number is used must be enabled by setting the appropriate S2-n switch ON. S2-1 is for reader 1, S2-2 is for reader 2, etc. S4 is used to terminate the two wire, half duplex RS485 signals at the istar. Wiegand Signaling Readers Wiegand signaling devices can be directly connected to WG Ports 1-8. In this case, the port number defines the reader number. If 22 or 24 AWG wire is used, the connection is limited to 200 feet. If 18 AWG wire is used, the distance can be up to 500 feet. The appropriate S2-n switch must be OFF to enable the Wiegand port. The pinout is shown in Table 4: TABLE 4. WG Port Pinouts WG Port Pin Number Signal/Function 1 Power (+12 vdc or +5 vdc) a 2 GND 3 Data 0 4 Data 1 5 Red LED (2 wire) 6 Yellow LED (1 wire) 7 Green (2 wire) 8 Beeper a. The P34 jumper defines whether +5 VDC or +12 VDC is supplied through Pin 1 on all of the WG Port connectors. This jumper is factory set to +5 VDC. If the readers require +12 VDC, this jumper must be changed. Warning! If the jumper is set to +12 VDC and an older +5 VDC reader is connected, the reader may be damaged. 9
10 ACM Access Control Module(s) Inputs The wiring of supervised inputs is shown in the next two figures. Note that the resistor network is different for NO and NC switches. Normally Open (NO) Wiring Normally Closed (NC) Wiring Outputs The outputs are dry contact Class C relays that are rated at 5 amps. Since they are dry contact, the technician must supply external power. The following two examples show an electric strike wired as both Fail Secure and Fail Safe. 10
11 ACM Access Control Module(s) Fail Secure Wiring Fail Safe Wiring The C CURE 800 software must be used to configure the output as Normally Energized for the Fail Safe case. 11
12 ACM Access Control Module(s) LED s DS3 indicates power to the ACM. DS1 indicates Rx on the RS485 half duplex reader bus. DS2 indicates Tx on the RS485 half duplex reader bus. NOTE DS1 and DS2 should be on solid. If they are blinking, it indicates that something (e.g., reader, I/8, R/8, etc.) is configured in the software but is not seen by the hardware. This may or not be a hardware failure, depending on the intent of the technician. (i.e., It is possible to configure hardware before actually installing it.) If DS1 and DS2 are blinking, it does represent some overhead to the istar. DS4 - DS11 display the eight outputs on the ACM. Switches S5 Reset switch S2 Enable Wiegand Ports - See the preceding description of Wiegand and RM readers. It is possible to have any combination of Wiegand and RM readers on one ACM, but they cannot share the same reader number. If readers 1, 2, 3, and 4 are RM readers, then the Wiegand readers would have to be 5, 6, 7, and 8. In this case, S2-1 through S2-4 must be ON, and S2-5 through S2-8 must be OFF. S4 Terminate the RM RS485 Ports (STAR1-STAR8). These switches default to ON and generally should not be changed. Setting the switch to OFF places the STARn port in the middle of the RS485 chain. This allows the technician to connect two sections of a reader bus to this point. In this case, termination must be provided at the end of each of those connections, but not at the STARn connector. The recommendation is to not use this capability. It is provided for compatibility with the older istar s. If an older istar is being ported to the istar Pro, there are now eight RM ports per ACM instead of four. 12
istar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationCanlan INSTALLATION MANUAL
Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationCardax FT Controller 3000
Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More information8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.
8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationInstallation and Configuration Guide
Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.
More informationME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.
ME930C-RJ11 Line: RJ-11 ME930C-RJ11 MAIN MODULE Power -TD -RD INTERFACE MODULE (REAR CARD) TEST -Cntrl In -Cntrl Out Serial: DB25 CN. 7 8 SW1 JB2 1 2 3 RJ-11 CN. JB3 INTERFACE MODULE (REAR CARD) 1 2 3
More informationDGH A3000 Configuration Guide For use with DGH Modules
DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation
More informationSTAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions
STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions This STAR Comm Modem Kit was designed specifically for use with the Micro/PX-2000 micro. The STAR Comm Modem is an external modem that can
More informationIntelligent Devices IDI 1100 Series Technical Manual
Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved
More informationInstallation Instructions for UL Rev A
NetController II Installation Instructions for UL 864 30-3001-1008 Rev A Mounting Screw Andover Continuum Power Supply Connector Third-Party Power Supply Connector I/O Bus Connector Cover Mounting Screw
More informationUSB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply
USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual The USB to industrial 16-Port RS-422/485 Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your
More informationAR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationThis 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.
USB-4COMi-M USB to Quad RS-422/485 to Serial Adapter Manual The USB to Industrial Quad RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple. Connecting to a USB
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationCable Pinouts. SRP I/O Module
Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4
More informationUSB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 4.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
More information-C5RS-LC RS232 EXTENDER
XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the
More informationCR3000 Copy Reader. Installation Guide
CR3000 Copy Reader Installation Guide CONTENTS CONTENTS 1 CR3000 Installation Guide 1 What you get: 2 Installation Overview 3 Install the Reader 4 Mount the Reader 4 Connect the Reader Cables 5 Connect
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationInstallation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter
Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Introduction The USB to Octal Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your
More informationPDS200 Power over Ethernet Device Server User Manual
PDS200 Power over Ethernet Device Server User Manual ABOUT PDS200 is an external usage Power over Ethernet Device Server (Serial-to- Ethernet converter). It includes the function of GIGA-TMS s products-
More informationEIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs
EIDX_M Series A Line of Managed Ethernet Switching Hubs INTRODUCTION INSTALLATION GUIDE The EIDX_M Series of managed Industrial Ethernet switches provides the user with a sophisticated instrument with
More informationHardware User s Manual. Digital Video Motion Detector DVMD1-X
Hardware User s Manual Digital Video Motion Detector DVMD1-X Version 010 Revision A July, 2004 2395 Kenwood Drive Boulder, CO 80303 (303) 543-0440 TECHNICAL SPECIFICATIONS VENDOR Radiant Inc. http://www.dvmd.com
More informationRCS/6000. Hardware. Manual
RCS/6000 Hardware Manual Document number 80-001052-6 Revision A RCS/6000 Hardware Manual Document part number 80-001052-6 Revision History Date Revision Description 4/10/01 A Initial production release
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationEasySYNC Ltd. USB to Serial Converters Manual
EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationCDN502 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER
More informationModel: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:
Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect
More informationGV-AS200 Controller. Hardware Installation Guide
GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.
More informationFVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL
2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital
More informationEasySYNC Ltd. USB to Serial Converters Manual
EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-01-26 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232
More informationVMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /
VMI E-Series Virtual Mixer Interface Technical Documentation 600 Industrial Drive, New Bern, N.C. 28562 (tel 252-638-7000 / fax 252-637-1285 / email@wheatstone.com ) VMI E-Series Virtual Mixer Interface
More informationSuprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502
Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control
More informationSection 1 INTRODUCTION
Table of Contents Section 1. Introduction 1 Section 2. Installation Wire Configuration 2 Section 3. Configuration RS-232 3 Wiegand Output Rules 4 Examples 5 Section 1 INTRODUCTION The Omni heavy-duty slot
More informationSPX-7400_SPX-7410_MAN_161028
Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400
More informationICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.
Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer
More informationSauter Systems
96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network
More informationPerle SMI Media Converter Installation Guide
Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter
More informationNETCOM2P Installation Guide
Specifications Input Requirements ed through control board NETCOM2P 140 ma control board 130 ma = 270 ma ed through CIM NETCOM2P 140 ma CIM 150 ma = 290 ma Network Interface (10/100 BaseT) Ethernet LAN/WAN
More informationAppendix A Cable Pinouts
Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationInstallation Guide. Avigilon ACM Embedded Controller
Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM
More informationQuick Installation Manual
Quick Installation Manual Please Note: Full Technical guide is located on the DVD if this is your first time installing a Hartmann Controls Access Control System. It is strongly recommended you review
More informationINSTALLATION INSTRUCTIONS
www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous
More informationGE Fanuc IC695CMM004. Rx3i PacSystem
GE Fanuc IC695CMM004 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic695cmm004 Rx3i PacSystem RX3i serial communications module. Four isolated RS-232/485 port. IC695C IC695CM IC695CMM 919-535-3180
More informationilock control unit Wiring Manual website: phone: +(48)
ilock control unit Wiring Manual e-mail: contact@ilocksystems.com website: www.ilocksystems.com phone: +(48) 61 669 06 87 1 P a g e Table of contents 1. Basic information... 2 1.1. Scheme 01... 3 2. Fingerprint
More informationRS-232 Connector Pin Assignments
APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial
More informationOSM Features: Field Configurable Reader,I/O to OSDP OSDP to Panel
OSM-1000 Universal OSDP Interface Module Series Features: Field Configurable Reader,I/O to OSDP OSDP to Panel Interfaces and Formats Wiegand ( 4 to 300 bits) F/2F (Binary, ABA) Strobed ( Wiegand, ABA )
More informationROCKETLINX ES7110 ES7110/ES7110-VB
ROCKETLINX ES7110 ES7110/ES7110-VB QUICK INSTALLATION GUIDE 2000550 Rev E Release Date - August 2015 INTRODUCTION The RocketLinx ES7110 series is an industrial Power over Ethernet (PoE) switch with eight
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationUSB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features
USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.
More informationConnector and Cable Specifications
APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,
More informationmodunet292: novanet-ethernet interface
SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation
More informationrdczbk User Manual ZigBee to RS-232 / RS-485 Converter
1. Product Overview rdczbk User Manual ZigBee to RS-232 / RS-485 Converter Robust DataComm Pte Ltd The rdczbk is basically a XBee / XBee Pro carrier board that provides either RS-485 or RS-232 connectivity
More informationConettix ITS-D6686-INTL
Conettix ITS-D6686-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationSuprex Ethernet SPX-7200 Ethernet Reader-Extender
Suprex Ethernet SPX-7200 Ethernet Reader-Extender Product Manual 1 SPX-7200_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems
More informationThe specifications for the Cisco 7304 router are listed in Table A-1.
APPENDIX A This appendix provides system and component specifications for the Cisco 7304 router. The following topics are found in this appendix: System, page A-1 Processor and Memory and Configurations,
More informationWiring Guide EP.HIO. Version 1.03 Last Updated:
Wiring Guide EP.HIO Version 1.03 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual Platform1 version 3 support 6 and 10
More information16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch
12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:
More information7I74 MANUAL 8 CHANNEL RS-422 INTERFACE
7I74 MANUAL 8 CHANNEL RS-422 INTERFACE V1.2 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................
More informationPACSystems* RX3i IC695CMM002 and IC695CMM004
May 2010 PACSystems* RX3i IC695CMM002 and IC695CMM004 Serial Communications Modules PACSystems* RX3i Serial Communications modules expand the serial communications capabilities of the RX3i system. Serial
More informationVorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual
Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric
More informationINSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents
INSTALLATION INSTRUCTIONS MicroComm DXL DCC and DCE Installation Instructions Table of Contents 1. Intent & Scope 1 2. Description 1 3. DCC Backup Battery 2 4. Field Connections to the DCC 4 5. Field Connections
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationRS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual
RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...
More informationAUTOLOG GSM-PLC STEP BY STEP
AUTOLOG GSM-PLC STEP BY STEP AutoLog GSM4 Unit with power supply: Open the cover with screwdriver (GSM4 Unit in picture): Open the cover with screwdriver (GSM14 Unit in picture): AutoLog GSM4 Unit with
More informationOPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B
OPERATIONS MANUAL n.form I/O Expander (RACK MOUNT) Document Number: 200-0009 Rev B table of contents INTRODUCTION FEATURES & CAPABILITIES 1 WIRING General I/O Configuring The System Using The System 4
More informationUpdating Reader Firmware
SWH-xxxx Readers Updating Reader Firmware Version C0 Document Part Number UM-096 July 2012 OVERVIEW This document describes how to download new firmware to Software House SWH-4xxx readers. The procedure
More informationUPDATING THE FIRMWARE IN FRAME BASED MODULES...
7700/7800 MultiFrame Manual TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. REQUIREMENTS... 1 1.1.1. Requirements Serial Port Upgrade Method... 1 1.1.2. Requirements FTP Upgrade Method (For VistaLINK Capable Modules
More informationT3 Interface Converters
MT1103A JULY 2003 MT1103A-DC T3 Interface Converters CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day,
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More informationNCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationGetting started with your DGH module:
Getting started with your DGH module: This document contains step-by-step instructions to quickly connect and communicate with your new DGH modules. For most applications, new modules require a one-time
More informationME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.
ME778C-RJ45 Line: RJ-45 MAIN MODULE Mini Driver MP Card ME778C-RJ45 Power Line: RJ-45 Unit A -TD -RD -CD -TD Serial: 10-Pin RJ INTERFACE MODULE (REAR CARD) Unit B -RD -CD Serial: 10-Pin RJ LO Z A HI Z
More informationCDN503 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER
More informationSECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel
SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with (SK-MRCP) -Door Panel WITH RS- GATEWAY CONNECTED DIRECTLY TO A PC RS- GATEWAY POWER: EIGHT (8) SMART READERS EVENLY SPACED UP TO 000
More informationSerial to LANC Adapter User s Guide
Serial to LANC Adapter User s Guide Thank you for purchasing our controller product. The following information will help you successfully connect this controller board and get it running in your application.
More information4170 POS System Installation Guide
4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document
More informationSupervised Input Module Installation Manual
Intelligent Access Control Systems Supervised Input Module Installation Manual 33-10037-001 REV: B PCSC 3541 Challenger Street Torrance, CA 90503 Phone: (310) 638-0400 FAX: (310) 638-6204 www.1pcsc.com
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationINTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx
INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box
More information716 Converter. Programmable Data Converter
716 Converter Programmable Data Converter The 716 can perform over 30 different conversions, supporting Rs232, wieigand, magnetic stripe, wieaba, wand emulation, f2f, and others. Flash upgrading allows
More informationBAYTECH REMOTE POWER CONTROL UNIT FOR MODELS RPC-2 RPC-2A RPC-2 MD01 RPC3-15
OWNER S MANUAL BAYTECH REMOTE POWER CONTROL UNIT FOR MODELS RPC-2 RPC-2A RPC-2 MD01 RPC3-15 Amp RPC3-20 Amp RPC-3A RPC-4 RPC-5 RPC-7 RPC-21 BayTech Manual Publication #U140E125-05 January 2000 Copyright
More information