Technical Manual Nova: Cabinet Security Management System (CSMS)

Size: px
Start display at page:

Download "Technical Manual Nova: Cabinet Security Management System (CSMS)"

Transcription

1 Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1

2 Publication May, 2016, Keyprocessor BV Paasheuvelweg BJ Amsterdam, The Netherlands This manual represents the knowledge at the above mentioned time. Keyprocessor works nonstop to improve her products. For the most recent technologic information please contact your consultant or dealer. Content overview Publication... 2 Content overview Connecting the Nova CSMS hardware Setup Nova CSMS internet connection Local network settings Get an activation key Installing and register the Nova application add a cabinet Cabinet overview User list Access Settings Alerts Logout Upload firmware into Nova Technical information KP_nova_TM_160501_EN 2

3 1 Connecting the Nova CSMS hardware Mount Nova CSMS into your cabinet, and install all the sensors into the cabinet Port Section color Description Gray Network connection 1 Yellow Temperature / Humidity sensor 3 Green Card reader 4 Green Lock 7 Red Door sensor (front) 8 Red Door sensor (back) 9 Red Smoke detector 15 Blue Water detector Do not remove red plugs into the ports (see above drawing). Using these ports can damage Nova CSMS and / or sensors. These ports are for future functions. Mount Nova in a cabinet, save from excessive dust and with sufficient flow of air. Temperature (-10 C ~ +60 C) and humidity (20 ~ 90%) may not be out of range. The yellow temperature / humidity sensor cable must be installed isolated from Power cables (e.g. 110V / 230V / 400V). If you are using a yellow temperature / humidity sensor, only use supplied yellow sensor cable. Use of other (straight patch) cables will damage the sensor. If you are using a black temperature / humidity sensor, only use straight patch cable. KP_nova_TM_160501_EN 3

4 2 Setup Nova CSMS internet connection Nova CSMS needs a fixed wired connection to the internet. Otherwise there is no possibility to control Nova CSMS and your cabinet. Follow below steps to install your Nova CSMS and Android (>Android 4.3) or IOS application for your mobile device. Communication to the cloud service is made over a SSL Tunnel on port 80 NovaCloud is using port 9095 so the internal network has to allow connection to cloud1.novacloudsecurity.com: Local network settings Connect Nova to your laptop / PC with a Ethernet cable from Nova to your Ethernet connection on your laptop / PC. Nova uses a fixed IP address. Factory setting is Go to the network and sharing center of your laptop / PC and change the adapter settings of your Local Area Connection. Change IPv4 into a fixed IP in the range of xxx. Change it for example into Also change the Subnet mask into and save the changed settings. Browse via your laptop / PC to the Nova using the URL: The following page will be displayed: Change network settings according the settings of your local network. KP_nova_TM_160501_EN 4

5 Set the IP-, Netmask-, Default gateway- and DNS address. Press save and the Nova CSMS will be rebooted automatically. Wait about 5 minutes before Nova completed the reboot. Disconnect Nova CSMS from your Laptop / PC and connect the Ethernet cable to your network switch or network router. Change the IPv4 settings of your laptop / PC into the conventional settings (probably obtain an IP address automatically, so your laptop / PC is able to connect to internet again. For technical information when using SNMP please contact your distributor Get an activation key to obtain admin rights Browse to the Nova CSMS using the new IP address. In this example Open the tab Activate. Press the button Get key. When there is no internet connection, the following message will displayed Error - try again later or It is possible that the Nova is not ready yet after re-start. Otherwise, please check the internet connection or the changed IP address in Nova CSMS. Write down the activation key. Add the activation key into your Nova application to setup the connection between the mobile device and Nova. The generated key is valid for only 10 minutes. After this time you should generate a new key. We recommend that you download the Nova application on your Android or IOS device first (see chapter 3) KP_nova_TM_160501_EN 5

6 3 Installing and register the Nova application Open the Google Play App Store or the iphone App Store and search for the Nova Cloud Security application and download the app. Open the Nova application on your device. Press: Create account. o Enter account. o Password. o Repeat password. o Register (Registration successful: an activation link will be sent to your ). Click on the activation URL in your . You can now use this account to log in to the application. Log into the application. When the Nova CSMS is registered, the username and password of the administrator can be used to login again and change the settings. 3.1 add a cabinet Press at the top of the Nova application the symbol, to add a new cabinet. Add the activation key, generated in chapter Add the name of the cabinet. This must be a unique name. Add the location name of the cabinet. (e.g. city, floor, department etc. not needed to be unique) Press: accept. The cabinet is added to the application. Repeat the above steps to add another cabinet. With the symbol, you can remove a cabinet Cabinet overview Select at the bottom of the Nova application the symbol. Select a cabinet. All the details of the cabinet will be displayed here. Press on the values of the temperature / humidity sensor to change the warning levels. Press on smoke to check the status- and to reset the smoke detector. Press on door to check the door status and to release the door. Press on water to check the water detector status. Press to go back to the main screen. KP_nova_TM_160501_EN 6

7 3.1.2 User list Select at the bottom of the Nova application the symbol. Press on to add a new person who may control the cabinet with the application. This address should be of a registered user. If the user is not registered yet, they will receive an invitation. The user has to install the application on his device before he can control the cabinet. Give the user access (no yes) and press the invite button. With the symbol, you can remove a user Access Select at the bottom of the Nova application the symbol. Usable Accessibilities: only PIN, only card / tag, card / tag and PIN. Press on to add a new person who may have access the cabinet using a Nova tag / card. Add a Name. Hold the Nova tag / card against the reader. The card number will be filled in automatically. When using a PIN card reader you can add a PIN. PIN is not mandatory Add the cabinets to which this person may have access. Press the Save button. With the symbol, you can remove a tag or card Settings Select at the bottom the Nova application the symbol. Activate the Notification (alarm) button to receive push messages on your mobile device when an alarm has occurred. Activate the Notification (warning) button to receive push messages on your mobile device when a warning has occurred. The push messages will only be sent when the application is closed. KP_nova_TM_160501_EN 7

8 3.1.5 Alerts Select at the bottom of the Nova application the notifications are displayed. Press the button to dismiss all notifications. Green symbol: OK. Yellow symbol: Warning Red symbol: Alarm symbol. All the alarms- and Logout Press the (menu) button to logout. KP_nova_TM_160501_EN 8

9 4 Upload firmware into Nova Your Nova is provided with the latest firmware before leaving the factory. If there is a new firmware available, you can download it from the knowledge base of or the website of your supplier. Save the latest firmware on your laptop / PC. Browse on your laptop / PC to port 8081 of the Nova e.g. The above indicated IP address is an example. Use the real IP address of the Nova you want to update and add :8081 Username: root Password: iekp47 Select the new file(s) and press upload. After a successful installation, Nova CSMS will be rebooted automatically. KP_nova_TM_160501_EN 9

10 5 Technical information Housing Description: 19 inch, 1HE metal housing Measurements: 482,6mm x x (W x H x D) Weight 3,5Kg Consumption Power consumption (no load) <7.0W Power consumption (maximum) Single non-redundant power supply; max. power supply rating 53.92W at >74% efficiency (refer to output load de-rating curve) Power supply VAC Input: Voltage VAC Current 1.6A/115VAC 1A/230VAC Frequency 47 ~ 63Hz range Battery charge: Current 160mA Power inlet: Fuse 2A/T Type IEC, C14 Protection: Overload 105 ~ 150% rated output power Protection type : AC Charging Mode : Hiccup mode, recovers automatically after fault condition is removed Over Voltage CH1:31.74 ~ 37.26V Protection type : Hiccup mode, recovers automatically after fault condition is removed Battery low 20 ~ 22V Battery Input Battery type 24V lead acid gel batteries Battery charge: Current 2A (Polyfuse protection) Environment Operating temperature: Non-operating altitude: Operating altitude: Working humidity: Storage temp., humidity: Polyfuse -10 C to +60 C at sea level m ( ft.) Operating altitude: Up to 3.000m (9.000 ft.), max. ambient temperature is derated by 1 C per 300m above 900m 20 ~ 90% RH non-condensing -20 ~ +85 C, 10 ~ 95% RH Type PTC Fuse Case style Thermal derating At -10 C the hold current will increase to 130% At +25 C no derating At +60 C the hold current will reduced to 60% Certifications CE compliant EMC (electromagnetic compatibility): EN (2010) + AC (2011), class B EN (2006) + A1 KP_nova_TM_160501_EN 10

11 (2009) + A2 (2009) EN :2008 Hardware Immunity: EN 55024:2010 Low Voltage (Product EN (2006) + A11 safety): (2009) + A1 (2010) + A12 (2011) Output voltage 12VDC max. 500mA (polyfuse) 24VDC max. 200mA (polyfuse) Connections Sensor Port 1 Temperature/Humidity sensor Reader 1 Port 3 12 VDC Sirius card reader Lock Port 4 24 VDC max. 1A (polyfuse); (switched by relay; NO/NC). RS485 bus Port 5 Future use Door status 1 Port 7 DEOL resistors (4k7) Reset Switching to Door status 2 Port 8 DEOL resistors (4k7) ground Smoke detector Port 9 12 VDC DEOL resistors (4k7) Water detector Port VDC Switching to ground Cooling FAN No cooling FAN inside Indicators LED Support 12x green LED The cloud server will be updated and supported when necessary to guarantee the most secure platform. These measures can cause a short downtime of the server. KP_nova_TM_160501_EN 11

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

AC-DC Converter REC K10

AC-DC Converter REC K10 Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SED2 VFD NEMA Type 3R Bypass/Air Conditioner SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual EMC-1 TM Ethernet Meterbus Converter Installation and Operation Manual DIMENSIONS [inches (millimeters)] 4.85 ( 123 ) For the most recent manual revisions, see the version at: www.morningstarcorp.com 3.37

More information

EnCell Battery Cell Monitor

EnCell Battery Cell Monitor EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,

More information

Hardened Web-Smart High Power PoE Ethernet Switch

Hardened Web-Smart High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart High Power PoE (Power over Ethernet) Ethernet Switch. This is the switch of choice for harsh environments

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

VIDI System Controller

VIDI System Controller 1 VIDI System Controller for OPUS DC Power Systems Product description VIDI is the advanced monitoring and control device for OPUS DC Power Systems. It delivers intelligence, an easy-to-use interface and

More information

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

SSW06. Soft Starters.

SSW06. Soft Starters. The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation

More information

Citrix CloudBridge CB User Manual

Citrix CloudBridge CB User Manual Citrix CloudBridge CB 504-2 User Manual 1 P a g e Chapter 1 CloudBridge Hardware Platform Topics: Citrix CloudBridge CB 504-2 Summary of Hardware Specifications The Citrix CloudBridge CB 504-2 hardware

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data Publication January 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com

More information

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers. General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

Technical Release notes iprotect Aurora 8.02

Technical Release notes iprotect Aurora 8.02 Technical Release notes iprotect Aurora 8.02 o System requirements o Highlights new version o New features in iprotect Publication January, 2015 Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam www.keyprocessor.com

More information

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603) Technical Data Sheet 750 Watt, 12 Volt, Single Output Power Supply With PFC, Voltage & Current Trim Functions UNIT CODE PS-RSP 750-12 DESCRIPTION 750 Watt 12 Volt, Single Output Power Supply with PFC plus

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

Neon pr. ph/ ORP measurement. Applications. Description

Neon pr. ph/ ORP measurement. Applications. Description Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

User Manual. cmt-iv5 Startup Guide

User Manual. cmt-iv5 Startup Guide User Manual cmt-iv5 Startup Guide v 2.2 JAN 8, 2016 Table of Contents Chapter1. Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Ethernet port... 3 1.4. CR1225 battery... 3 1.5. Power connection...

More information

AC-DC Converter REC /60-K20

AC-DC Converter REC /60-K20 Thanks to the variety of modules available, the REC3200-230-48-K20 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter

More information

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range Power supplies CP-E, CP-S and CP-C range CP-E Range The new CP-E range power supplies M odern switch mode AC to DC power supplies are a vital component in most information gathering systems, energy management,

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up

More information

Orion bus communication iprotect 8.03

Orion bus communication iprotect 8.03 Orion bus communication iprotect 8.03 o Basic implementation Guide lines 1 Publication June, 2015 Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam www.keyprocessor.com Tel.: +31-20-4620700 This manual

More information

Table of Contents. Chapter 1 Introduction Chapter 2 Quick Install... 7

Table of Contents. Chapter 1 Introduction Chapter 2 Quick Install... 7 AVA-88 WELCOME Congratulations on purchasing the AVA-88. The AVA-88 integrates multiple complicated control, automation and internet protocols into one simple plug-and-play device. It is a central controller

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

PRODUCT FEATURES AND ADVANTAGES

PRODUCT FEATURES AND ADVANTAGES Flatpack2 24/1800 HE 24VDC Rectifier/Converter Modules The combination of innovative design, efficiency and reliability makes the Flatpack2 HE stand out. With efficiency up to 96.2%, the losses have been

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Technical data. Safety notes. Product features

Technical data. Safety notes. Product features Technical data sheet BKN230-MOD 11-00002.F Communication and power supply unit for motorised fire dampers Communication via RTU (RS-48) AC 230 V supply via Euro plug Power is supplied to the actuators

More information

Hardware Installation

Hardware Installation LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies

More information

Installation and User Guide

Installation and User Guide D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect

More information

AC-DC Converter RECE K21

AC-DC Converter RECE K21 Thanks to the variety of modules available, the RECE3200-230-48-K21 system offers the perfect solution for all areas of applications requiring a power output of up to 3,2kW. Modular Battery Charger / Inverter

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

E1 Plus Electronic Overload Relay

E1 Plus Electronic Overload Relay ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

5 MICROMASTER 420 specifications

5 MICROMASTER 420 specifications Issue 10/06 This Chapter contains: Table 5-1 Table 5-2 Table 5-3 Table 5-4 contains the general technical specifications for the MICROMASTER 420 inverter contains terminal tightening torques contains information

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

Operation Manual SuperDry Data Logger (SDDL)

Operation Manual SuperDry Data Logger (SDDL) Operation Manual SuperDry Data Logger (SDDL) 1. Description This device has been equipped with custom-programmable logic module, mounted in it s own housing. The respective module serves to measure the

More information

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC) Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart PoE (Power over Ethernet) and High Power PoE Ethernet Switch. This is the switch of choice for harsh environments

More information

ELED /700D 20W Multiple-Stage Output Current LED Driver

ELED /700D 20W Multiple-Stage Output Current LED Driver Features: Output constant current Range 100-265VAC Built-in active PFC function Efficiency 86% Max Protections: short circuit/over load/ over current/ Cooling by free air convection IP20 design for indoor

More information

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW) Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product

More information

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs

More information

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data

Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data Installation manual Card reader Sirius i80(p) o Product o Installation o Connection o Technical data Publication January 2014, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com

More information

12-15VDC (12V±5%) 24-28VDC (24V±5%)

12-15VDC (12V±5%) 24-28VDC (24V±5%) Features Description Universal AC input (85-264VAC) Long 7 year warranty Protections: SCP, OVP, OCP, OTP 1% full load burn-in test DC OK indicator LED with relay contacts cooling by free air convection,

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home HYBRID PV INVERTERS HySpirit Series Hybrid Inverter with Battery Backup Smart Energy for Smart Home 4kW-10kW FSP HySpirit series Offers a more intelligent power solution for our customers to reduce the

More information

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS 2MOPP Medical FEATURES Universal Input Range Operating Temperature Range: -25º to 80ºC (with derating) Compact Package: 2.00 3.00 1.16

More information

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available ECM40-60 40 & 60 Watt Models Small Size 2.0 x 4.0 x 1.2 Low Leakage Current Industrial & Medical Approvals Full Load Available Convection Cooled Wide Operating Temperature 0 C to +70 C Level B Conducted

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF

Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVFF ype VariFlex 3 RVFF RVFF AC variable speed drive for use with AC induction motors Sensorless vector control or V/F, SLV, PMSLV with space vector PWM mode Input voltage ranges: 3-ph 480VAC 150%/1Hz (vector

More information

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

SPECIFICATIONS. Input Output Agency Approvals

SPECIFICATIONS. Input Output Agency Approvals Technical Data Sheet 1,500 Watt 12 Volt, Single Output Power Supply with PFC and Parallel Functions UNIT CODE PS-RSP 1500-12 DESCRIPTION 1,500 Watt, 12V, Single Output Power Supply with PFC and Parallel

More information

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information

More information

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES www.unipowerco.com Manual No. PDUAC1USM-2 pduac1us-man-rev2-0115.indd 2015 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive,

More information

A0750 AC-DC POWER MODULE

A0750 AC-DC POWER MODULE FEATURES High power density, 7.7W / in³ Net Weight:< 2.2 KG Low profile : 40.8mm (fit 1U 19 shelf R2250 series) Efficiency: 77% ~ 86 % typical Power factor correction (meet IEC1000-3-2 requirements) Overvoltage

More information

DPS240/12V Dimmable Power Supply Custom LitePad

DPS240/12V Dimmable Power Supply Custom LitePad Rosco s DPS240/12V Dimmable Power Supply is designed to complement larger Custom LitePad installations. The system comes with power supply and controller all pre-wired and ready to integrate with an array

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A #95101 0517 Input/Output Network Adaptor Programming Manual For use with IX Series,, and IPW-1A ATTENTION: This is the programming manual for the RY IP44 only. Refer to the Installation and Setting Manuals

More information

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2

More information

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 20 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Phaseo Battery

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

S025W-056C W Programmable LED Drivers

S025W-056C W Programmable LED Drivers Rev 12-14-17 Electrical Specifications Maximum Power: 25W Typical Efficiency: 88% Input Voltage Range: 1-277 Vac Nom. (108-305 V Min/Max) Frequency: 50/ Hz Nom. (47-63 Hz Min/Max) Power Factor: 0.90 @

More information

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web:   ; User s Manual Management Converter Chassis Model No.: SP1386 / SP1387 World Wide Web: www.micronet.com.tw ; www.micronet.info Table of Content 1. INTRODUCTION... 2 1.1 PACKAGE CONTENT... 2 1.2 KEY FEATURES...

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp) Product availability : Stock - Normally stocked in distribution facility Price* : 1468.00 USD Main Range

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

GAMATRONIC, A SolarEdge Division.

GAMATRONIC, A SolarEdge Division. GAMATRONIC, A SolarEdge Division. 17 Hartum Street, POB 45029, Jerusalem 9777517,Israel Tel: +972-2-5888222 Fax: +972-2-5828875 e-mail: info@gamatronic.com www.gamatronic.com The Power+ Premium 60 is

More information

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 5 A Main Range of product Product or component type Power supply type Input voltage Output voltage Rated power in W Input protection

More information

the Centric 300 An advanced modular UPS up to 1800kVA/kW

the Centric 300 An advanced modular UPS up to 1800kVA/kW the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has

More information