3RV1 Circuit-Breakers

Size: px
Start display at page:

Download "3RV1 Circuit-Breakers"

Transcription

1 SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories NSK-7715a 4 Circuit-breaker S0 with mountable accessories NSK-7716a 4 Mountable accessories for size Mountable accessories for size Mountable accessories for size a Transverse auxiliary switch S00 to S3 5.1 Undervoltage release with S00 h Signalling switch S0, S2, S3 leading auxiliary contacts s Lateral auxiliary switch S00 to S3 d Shunt release S00 to S3 5.2 Undervoltage release with S0 to S3 j Isolator module S0 and S2 leading auxiliary contacts f Undervoltage release S00 to S3 2/26 Siemens NS K 2000

2 SIRIUS 3R Description Remote-controlled motorized operating mechanism 3RV1 circuit-breakers are manually operated switching devices. They automatically trip in case of an overload or short circuit. Intentional, remote-controlled tripping is possible by means of a shunt release or an undervoltage release. Reclosing is only possible directly at the circuit-breaker. The remote-controlled motorized operating mechanism allows the circuit-breakers to be opened and closed by electrical commands. This enables a load or an installation to be isolated from the power system or reconnected to it from an operator panel. The remote-controlled motorized operating mechanism is available for circuit-breakers of sizes S2 (I nmax. = 50 A) and size S3 (I nmax. = 100 A) that are designed for control voltages of AC 230 V or DC 24 V. The circuit-breaker is fitted into the remote-controlled motorized operating mechanism as shown in the block diagram. The circuit-breaker in the remote-controlled motorized operating mechanism can still be switched locally in the "MAN- UAL" position. In the "AUTO- MATIC" position, the circuitbreaker is switched by means of electrical commands. The switching commands must be at least 100 ms long. The remotecontrolled motorized operating mechanism closes the circuitbreaker after 1 second at the latest. In the event of a power failure during the switching operation, the circuit-breaker is guaranteed to remain in the ON or OFF position. Siemens NS K /27

3 SIRIUS 3R Description Mounting accessories Door-coupling rotary operating mechanisms Circuit-breakers with a rotary operating mechanism can be mounted in a cubicle and operated externally by means of a door-coupling rotary operating mechanism. When the cubicle door is closed, the operating mechanism is coupled. The coupling locks when the circuit-breaker is closed. Inadvertent opening of the door is prevented. This lock can be defeated by the maintenance staff. In the OFF position, the rotary operating mechanism can be prevented from reclosing by means of up to three padlocks. Once again, inadvertent opening of the door is impossible. Enclosures Moulded-plastic enclosures with various dimensions for wall or flush mounting are available for installing individual circuitbreakers of sizes S00(I nmax. = 12 A) S0(I nmax. = 25 A) S2(I nmax. = 50 A) The enclosures for wall mounting are designed for degree of protection IP 55, and the enclosures for flush mounting also fulfil degree of protection IP 55 on the front (the flush-mounted section complies with IP 20). All enclosures are equipped with N and PE terminals. Two knockout cable entries for cable glands are provided at both the top and bottom, and further suitable entries are also premoulded on the rear. There is a knockout for indicator lights, which are available as accessories, on top of the enclosure. A circuit-breaker without accessories, equipped with one transverse and one lateral auxiliary contact, can be fitted into the narrow enclosures. In the wide enclosures and in the enclosure for S2 circuit-breakers there is also sufficient space for a laterally mounted auxiliary release. Circuit-breakers with a signalling switch cannot be installed in the enclosures. S00 circuit-breaker in enclosure with EMERGENCY STOP mushroom button With S00 circuit-breakers, the switch rocker is operated via the actuator diaphragm of the enclosure. A locking device, capable of holding up to three padlocks, can be fitted onto the actuator diaphragm. These padlocks prevent the circuitbreaker from closing during maintenance work, for example. A mushroom-shaped EMER- GENCY STOP handle can be fitted in place of the locking device. If it is actuated abruptly, the circuit-breaker opens and the mushroom-shaped handle latches. The handle can be unlatched again either by turning it or by using a special key. The circuit-breaker can then be reclosed. The moulded-plastic enclosures of S0 and S2 circuit-breakers with a rotary operating mechanism are also fitted with a rotary operating mechanism. S2 circuit-breaker with attached isolator module and padlock The enclosures are available with black rotary operating mechanisms or with EMER- GENCY STOP rotary operating mechanisms with a red/yellow handle. All rotary operating mechanisms can be locked in the OFF position with up to three padlocks. Front plates Circuit-breakers are frequently required to be actuated in any enclosure. Front plates that include an actuator diaphragm for size S00 circuit-breakers or a rotary operating mechanism for size S0 to S3 circuit-breakers are available for this purpose. The front plates for size S00 are are equipped with a retaining frame, into which the circuitbreakers can be snapped. For the front plates for sizes S0 to S3, a retaining frame for size S0 circuit-breakers is available. 2/28 Siemens NS K 2000

4 SIRIUS 3R Description Mountable accessories Busbar adapters The circuit-breakers are mounted directly with the aid of busbar adapters on busbar systems with 40 mm and 60 mm centre-line spacing, in order to save space and to permit infeed times and costs to be cut. Busbar adapters for busbar systems with 40 mm centre-line spacing are suitable for copper busbars with a width of 12 to15 mm, while those with 60 mm centre-line spacing are suitable for widths of 12 to 30 mm. The busbars can be 4 to 5 mm or 10 mm thick. The circuit-breakers are snapped onto the adapter and connected on the line side. This prepared unit is then plugged directly onto the busbar system, and is thus connected both mechanically and electrically at the same time. Refer to page 2/10 for busbar adapters for individual circuitbreakers and accessories. Other busbar adapters for snap-mounting direct-on-line starters and reversing starters, as well as additional accessories such as line terminals and outgoing terminals, busbar copper, etc., can be found in Part 13. Insulated 3-phasebusbar systems 3-phase busbar systems provide a simple, time-saving and straightforward means of feeding a series of adjacent 3RV1 S00, S0 and S2 circuit-breakers which are snap-mounted on a standard mounting rail. The busbars are suitable for between 2 and 5 circuit-breakers. Any kind of extension is possible however by clamping the tags of an additional busbar (rotated 180 ) underneath the terminals of the last circuitbreaker. Different sized circuit-breakers cannot be clamped together due to the different fixing dimensions. Special connectors are available for connecting 3- phase busbars for S0 circuitbreakers to busbars for S00 circuit-breakers. Busbars with larger modular spacings can be used for circuit-breakers with laterally mounted accessories. The circuit-breakers are supplied via appropriate line-side terminals. 3-phase busbar systems are safe against finger touch. They are designed for short circuits of the kind that can occur on the load side of the connected circuit-breakers. SIRIUS circuit-breaker and load feeders with busbar adapters snapped onto busbars Solder pin connections Solder pin connections are available for the main contacts and for the transverse auxiliary switch of S00 circuit-breakers. The prepared connecting parts are clamped into the upper and lower screw terminals of the circuit-breakers, allowing the latter to be soldered to a printed-circuit board. Plug-in socket A plug-in socket is available for S3 circuit-breakers (I nmax. = 100 A). In addition to the plug-in socket, the installation kit also contains 6 plug-in contacts, which are necessary to convert the fixed-mounted circuitbreaker to a plug-in circuitbreaker. A specially adapted circuit-breaker should be used in conjunction with the plug-in socket (see page 2/10). Due to the risk of arcing, a closed circuit-breaker must never be pulled out of the plugin socket or plugged into it. A tripping pin on the circuitbreaker is therefore activated if an attempt is made to do so. This tripping pin only allows the circuit-breaker to be closed when it is plugged in and trips the breaker if an attempt is made to remove it. Rear connection Circuit-breakers are usually connected on the front. It is often preferable to connect the circuit-breaker on the rear however, for example in the case of large circuit-breakers and conductor cross-sections or if a busbar is connected. A "rear main conductor connection" kit be supplied for S3 circuit-breakers, to enable this alternative to be offered for SIRIUS 3R circuitbreakers as well. Siemens NS K /29

5 SIRIUS 3R Circuit diagrams Internal connections Circuit-breakers Circuit-breaker Circuit-breaker 3RV10.. 3RV14.. 3RV16.. 3RV11.. 3RV13.. Shunt release Undervoltage release Undervoltage releases with leading auxiliary contacts 3RV D 3RV A 3RV C 3RV C Transverse auxiliary switches (optionally mountable) Lateral auxiliary switches (optionally mountable) Signalling switch (can also be mounted together with auxiliary switches) 3RV D 3RV E 3RV A 3RV B 3RV C 3RV M (sizes S0 to S3) v NSK-7639d External connections Shunt release Undervoltage release L1(L+) F1 S0 Q1 N(L2,L-) 12 14(14) S 11(13) C1 F3 F2 C2 NSK-7640b S0; S1; S2 Q1 S F1; F2 F3 F4 OFF pushbuttons in system Circuit-breaker Auxiliary switch of circuit-breaker Q1 (transverse or lateral) Fuses (gl/gg) max. 10 A Shunt release Undervoltage release 2/30 Siemens NS K 2000

6 SIRIUS 3R Typical circuits 3RV1 circuit-breaker with 3RV M signalling switch H1: "Short circuit" signal H1; H2 Indicator lights H2: "Overload" or "Tripped by auxiliary release" signal F1; F2 Q1 S1 Fuses (gl/gg) max. 10 A Circuit-breaker Signalling switch Separate "Tripped" and "Short circuit" signals Circuit-breakers tripped by means of pushbutton or EMERGENCY STOP button in the system The undervoltage release with leading auxiliary contacts prevents the formation of vagabond voltages in the control circuit in the "OFF" position. In the "tripped" position of the breaker, these contacts are not guaranteed to open. F1; F2 Q1 F4 S1; S2, S3 Fuses (gl/gg) max. 10 A Circuit-breaker Undervoltage release OFF pushbuttons in system 3RV1 circuit-breaker with 3RV19 36/3RV19 46 remote-controlled motorized operating mechanism Circuit-breaker with relay function S1 S2 K1 F1; F2 Q1 OFF pushbutton ON pushbutton Latching contact Fuses gl/gg 6 A Circuit-breaker Siemens NS K /31

7 SIRIUS 3R Size S00 Size S0 3RV10 11 circuit-breaker 3RV10 21 circuit-breaker Size S2 3RV10 31 circuit-breaker 1) Lateral auxiliary switch 2) Signalling switch 3) Auxiliary release 4) Transverse auxiliary switch 5) Push-in lugs for screw mounting 6) Only for undervoltage release with leading auxiliary switch 7) Arcing space 8) 35 mm standard mounting rail acc. to EN ) Mounting on 35 mm standard mounting rail, 15 mm high, acc. to EN or on 75 mm standard mounting rail acc. to EN ) 4 mm hexagon socket screw 11) Lockable in 0 position with shackle diameter 5 mm Size S3 3RV10 41 circuit-breaker Height of arcing spaces a in mm Size Arcing spaces for limiter function in mm (see also page 2/18) U e [V] S00 S0 S2 S3 U e [V] S0 S2 S3 a a a a left/right top/bottom left/right top/bottom Size 2/32 Siemens NS K 2000

8 SIRIUS 3R Size S0 3RV11 21 circuit-breaker Size S2 3RV11 31 circuit-breaker a) Clearance from earthed parts 3) Auxiliary release 4) Transverse auxiliary switch 5) Push-in lugs for screw mounting 8) 35 mm standard mounting rail acc. to EN ) Mounting on 35 mm standard mounting rail, 15 mm high, acc. to EN or on 75 mm standard mounting rail acc. to EN ) 4 mm hexagon socket screw 11) Locking device Size S3 3RV11 42 circuit-breaker Siemens NS K /33

9 SIRIUS 3R Isolator module for circuit-breaker size S0 3RV A Isolator module for circuit-breaker size S2 3RV A Moulded-plastic enclosure for wall mounting 3RV a) 3RV C 85 mm 3RV D 105 mm b) Dimension refers to mounting plane 3) Knockout for Pg 16 4) Knockout for cable entry at the rear 5) With safety lock 6) Max. shackle diameter for padlock 8 mm 7) 3RV B indicator light 8) 3RV B locking device 9) 3RV EMERGENCY STOP mushroom button Moulded-plastic enclosure for wall mounting for circuit-breaker size S0 3RV ) 2) 4,5 Moulded-plastic enclosure for wall mounting for circuit-breaker size S2 3RV G 56 1) 2) RV B indicator light 3) a) NSK NSK a) 3RV C 85 mm 3RV D 105 mm 1) Knockout for Pg 16 2) Knockout for cable entry at the rear 3) Knockout for padlock with max. shackle diameter 8 mm 1) Knockout for Pg 21 2) Knockout for cable entry at the rear 2/34 Siemens NS K 2000

10 SIRIUS 3R Moulded-plastic enclosure for flush mounting 3RV D Moulded-plastic front plate 3RV B/-4C max ø ,5 R3 87, NSK , NSK-8521 Moulded-plastic enclosures for flush mounting 3RV D/-2G Solder pin connections for main and auxiliary contacts 3RV A 3RV B max , R3 NSK Moulded-plastic front plates and holder 3RV B 3RV G ø 3,5 40 7, , ,5 10 NSK Siemens NS K /35

11 SIRIUS 3R Door-coupling rotary operating mechanism for circuit-breaker sizes S0, S2, S3 3RV ) 13) 14) 15) Lockable in 0 position, max. shackle diameter 8 mm Fixing with screw cap As-delivered condition, adapt if necessary by shortening shaft; minimum length 45 mm Terminal block Remote-controlled motorized operating mechanism for circuit-breaker 3RV AP0 Busbar adapter for 40 mm busbar systems 8US DJ07 a) 3RV AP0 211 mm 3RV AP0 236 mm 4) For busbars width: 12 to 15 mm thickness: 5 and 10 mm a Busbar adapter for 40 mm busbar systems 8US FK08 s Lateral module 8US KB00 Busbar adapter for circuit-breaker size S3 for 40 mm and 60 mm busbar systems 8US SM NSK /36 Siemens NS K 2000

12 SIRIUS 3R Busbar holder for 40 mm busbar systems 3VX R Moulded-plastic cover for line-side terminals for 40 mm busbar systems 3VX S 4) For busbars width: 12 to 15 mm thickness: 5 and 10 mm 1) Busbar adapter for 60 mm busbar systems 8US DM07 2) Lateral module for 60 mm busbar systems 8US BM00 3) For busbar width: 12 to 30 mm thickness: 5 and 10 mm a Busbar adapter for 60 mm busbar systems 8US FM08 s Lateral module 8US BM00 Busbar adapter for 60 mm busbar systems 8US AA NSK ) For busbars width: 12 to 30 mm thickness: 5 and 10 mm 3-phase busbars 3RV for 2 circuit-breakers (length 90 mm): 3RV A for 3 circuit-breakers (length 136 mm): 3RV B for 4 circuit-breakers (length 181 mm): 3RV C for 5 circuit-breakers (length 226 mm): 3RV D 3-phase busbars for 2 circuit-breakers with accessories (length 109 mm) 3RV A for 4 circuit-breakers with accessories (length 235 mm) 3RV C Siemens NS K /37

13 SIRIUS 3R 3-phase busbars for circuit-breaker size S2 3RV for 2 circuit-breakers (length 111 mm) 3RV A for 3 circuit-breakers (length 166 mm) 3RV B for 4 circuit-breakers (length 221 mm) 3RV C 3-phase busbars for circuit-breaker size S2 3RV for 2 circuit-breakers with accessories (length 121 mm) 3RV A for 3 circuit-breakers with accessories (length 196 mm) 3RV B for 4 circuit-breakers with accessories (length 271 mm) 3RV C 3-phase line-side terminal connection from above 3RV A 3-phase line-side terminal connection from below 3RV B 3-phase line-side terminal for circuit-breaker size S2 3RV A Connector for circuit-breaker size S0 to size S00 3RV D NSK /38 Siemens NS K 2000

14 SIRIUS 3R Plug-in socket with busbar connection on rear for circuit-breaker size S3 Rear main conductor connection for circuit-breaker size S3 Plug-in socket with upper and lower terminal connections for circuit-breaker size S3 Siemens NS K /39

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS. 3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

Load Feeders, Motor Starters and Soft Starters

Load Feeders, Motor Starters and Soft Starters Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface, Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,

More information

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed

More information

Components for Distribution Systems

Components for Distribution Systems Components for Distribution Systems /2 Introduction Busbar adapter systems /4 General data /7 40 mm system / 60 mm system /12 Accessories /14 Project planning aids Door-coupling rotary mechanisms /23 General

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

3SU11 complete units 5

3SU11 complete units 5 5 5.1 Product description The 3SU11 complete units are a modular range of devices for front plate mounting and rear cable connection. Complete units made up of an actuating or signaling element and contact

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

ALPHA SIMBOX Small Distribution Boards

ALPHA SIMBOX Small Distribution Boards ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SF3 Limit, interlock and cable-operated Overview It is possible to directly connect selected limited, interlock and cable-operated switches via AS-Interface with safety-oriented communication. In these

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

Fast Bus Busbar System

Fast Bus Busbar System Busbar System Industrial Controls Product Catalog 2017 Section c o n t e n t s Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming

More information

Fast Bus Fast Bus Busbar System

Fast Bus Fast Bus Busbar System Fast Bus Busbar System Contents Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-... Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

Solid-State Switching Devices

Solid-State Switching Devices Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data

More information

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry. Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Press Shop

More information

References. References. Rating (A) Référence

References. References. Rating (A) Référence DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle

More information

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,

More information

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A)

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A) Make the Switch SPEEDY BUILD Rapid Run Service AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (0A - 150A) Your Specialist in CONTROL SOLUTIONS Contents 3. Surface Mounting IP65 Plastic

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Industrial Controls Product Catalog 2017

Industrial Controls Product Catalog 2017 Industrial Controls Product Catalog 2017 SIRIUS Section c o n t e n t s Thermal overload relays Solid state overload relays OVERLOAD RU21 overload relays up to 100 A with screw connection, CLASS 10 Page

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

Redline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2

Redline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2 Redline Extensions All MCB s (except G20), RCCB s (except Delta B) & RCBO s are designed to accept the same family of extensions. Main device ON Normal working status Addon Devices The extensions intended

More information

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA for ic60, iid, idpn Vigi, isw-na, RCA and ARA b The electrical auxiliaries are combined with ic60 circuit breakers, iid residual current circuit breakers, remote tripping switch disconnector isw-na, RCA

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Load Feeders and Motor Starters for Use in the Control Cabinet

Load Feeders and Motor Starters for Use in the Control Cabinet Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General

More information

Product and functional description

Product and functional description Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-... Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

SIMOCODE 3UF Motor Management and Control Devices

SIMOCODE 3UF Motor Management and Control Devices Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

IEC Power Control Overload Relays

IEC Power Control Overload Relays IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU21 overload relays up to 100 A with screw connection, CLASS 10 Page Selection and ordering data

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I

References. For front operation. For right side operation. Padlockable in position 0. Handle type. Frame size. Padlockable in position 0 and I DIRECT OPERATION T O O R D E R EXTERNAL OPERATION Fuse combination switches picto_080_c_1_gb_cat Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle Direct handle acces_147_a_2_cat

More information

8WH5 Combination Plug-In Terminals

8WH5 Combination Plug-In Terminals 8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-... Circuit Breakers, 09/074 Moeller Electric Corporation Auxiliary Contacts for Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic device N.O. N.C. Standard auxiliary

More information

Commanding and Signaling Devices

Commanding and Signaling Devices Siemens AG 200 Commanding and Signaling Devices /2 Introduction SB2 Pushbuttons and Indicator Lights, 16 mm / General data /7 Project planning aids SB Pushbuttons and Indicator Lights, 22 mm /8 General

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320

Program B3 318 Ø 22,5mm. Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Push Buttons Index Page Program B3 318 Ø 22,5mm Push Buttons 319 EMERGENCY STOP Buttons 320 Key Operated Rotary Switches 320 Rotary Knobs and Swing Knobs 321 Illuminated Rotary Knobs and Swing Knobs 321

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45 Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

Commanding and Signaling Devices

Commanding and Signaling Devices Commanding and Signaling Devices /2 Introduction SB2 Pushbutton Units and Indicator Lights, 16 mm / General data /7 Project planning aids SB Pushbutton Units and Indicator Lights, 22 mm /8 General data

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Three Phase Residential Solution for Australia, System Design and Installation Guidelines Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.

More information

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens

More information

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

2 PIECE BOARD-TO-BOARD

2 PIECE BOARD-TO-BOARD 2 PIECE BOARD-TO-BOARD 201-01-123 1. SPECIFICATION DISTRIBUTION No restrictions for issue 2. SCOPE This specification contains the application notes for the 9159 two part connectors. 3. PRODUCTS 10-9159

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP

ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type

More information

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)

MINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka) MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and

More information

the Santon FCS-type switch Disconnect Superior Switch Solutions

the Santon FCS-type switch Disconnect Superior Switch Solutions the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal

More information

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC

More information

IDG-B Enclosures for Industrial and Building Automation Controls.

IDG-B Enclosures for Industrial and Building Automation Controls. for Industrial and Building Automation Controls www.erni.com Katalog Catalog D E 074595 074518 Ausgabe 09/11 3, 03/05 www.erni.com Edition 2 1 www.erni.com Catalog E 074595 09/11 Edition 2 Table of Contents

More information

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation

More information

IEC Power Control Overload Relays

IEC Power Control Overload Relays IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU11 / 3RU1 overload relays up to 100 A with screw connection, CLASS 10 Page 3RB4 overload relays

More information

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories / SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Safety Systems Safety Integrated

Safety Systems Safety Integrated 3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored

More information

MMLG 01, 02, 03, 04 MMLB01

MMLG 01, 02, 03, 04 MMLB01 MMLG 01, 02, 03, 04 MMLB01 Technical Data Test Blocks and Test Plugs Publication Reference: MMLG_MMLB/EN/TD/B - ALSTOM 2015. All rights reserved. Information contained in this document is indicative only.

More information

SIRIUS 3RB2 Solid-State Overload Relays

SIRIUS 3RB2 Solid-State Overload Relays SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and

More information

WINSTA. Full Line Catalog 2008/2009

WINSTA. Full Line Catalog 2008/2009 WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

Protect Circuit Protection

Protect Circuit Protection Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description Multifunctional housing for complex electronics Data sheet 105504_en_01 PHOENIX CONTACT 2013-04-08 1 Description The housings of the ME PLC 40... product group consist of a 40-mm wide housing base with

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

Surface-Mounting Product Ranges

Surface-Mounting Product Ranges Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd

More information

RiLine Compact The smart power distribution system

RiLine Compact The smart power distribution system RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O