Wireless RS485 for KACO Link
|
|
- Meryl Rose
- 5 years ago
- Views:
Transcription
1 Wireless RS485 for KACO Link Introduction The SP PRO KACO Managed AC Coupling provides a method of linking the KACO Powador xx00 and Powador xx02 series grid tie inverters to the SP PRO AU or GO Series (SP PRO) via the AC Load supply so that regardless of whether the grid or a generator is connected, the SP PRO can manage and control the KACO grid tie inverters. Each SP PRO can manage a maximum of five KACO grid tie inverters by commanding each grid tie inverter to output the required amount of power. This is done via either a wireless or wired communications link which also serves to retrieve all the operational data from the KACO inverters for display and logging by the SP PRO. This document details the additional steps needed to install a Wireless RS485 link into a SP PRO KACO Managed AC Coupled system. The SP PRO and KACO inverters are installed as per their individual installation instructions with the additional allowance of communications cables and a Wireless RS485 linking communications between all of the inverters. Note: This document needs to be read in conjunction with IN00018-Installaion of Managed AC coupling, the SP PRO AU or GO Series Instruction Manual and the KACO xx02 Series or KACO xx00 Series Instruction Manual. Overview The diagram below (fig. 1) shows a typical single phase managed AC coupled system with five KACO inverters (Two direct connected and three via the wireless link). Fig. 1 Overview of single phase system using the Wireless RS485 IN0029 Revision 03 (005074) 1 of 15 POWER PERFORMANCE PASSION
2 The diagram below (fig. 2) shows a typical three phase managed AC coupled system with three KACO inverters per phase (one direct connected and two via the wireless link). A separate pair of wireless devices must be used for each phase. NOTE: When using multiple Wireless RS485 device pairs it is recommended that Patch Antennas be used on each of the devices at the local end of the system (SP PRO end). This will reduce the interference between devices and ensure trouble free operation. Fig. 2 Overview of three phase system using the Wireless RS485 IN0029 Revision 03 (005074) 2 of 15
3 The diagram below (fig. 3) shows a typical single phase managed AC coupled system with three separate remote locations. In this scenario each remote location is separated by a distance that cannot accommodate a hard wired connection between them. A separate pair of wireless devices must be used for each remote location. NOTE: When using multiple Wireless RS485 device pairs it is recommended that Patch Antennas be used on each of the devices at the local end of the system (SP PRO end). This will reduce the interference between devices and ensure trouble free operation. Fig. 3 Overview of single phase system using multiple Wireless RS485 IN0029 Revision 03 (005074) 3 of 15 POWER PERFORMANCE PASSION
4 Wireless link restrictions The wireless link uses the same frequency band as WiFi (2.4GHz). Any obstructions between the two devices or interference from other devices using the same frequency band (other blue tooth or WiFi devices) will have a significant impact on their range. To achieve the maximum range of 200m there must be line of sight between the two devices and no interference. As a rule of thumb each obstruction that is equivalent to a stud wall will reduce the distance by about 20%. Mud brick walls, double brick or concrete walls will have a much larger impact on the range. Any obstruction from the landscape such as levy banks, hills or undulation land will totally block the signal and the wireless link will not work. If more than one wireless link is required within the same installation (such as a three phase system or multiple remote sites) then the interference between the devices will further reduce the distance. In this case it is recommended that a patch antenna be used on all local Wireless devices Extending the Wireless Range If the required distance is longer than the specified 200m clear line of site, or there is multiple devices being used then the range of the devices can be extended by replacing the dipole antenna with a patch antenna. The table 1 below gives an indication of the expected range when using a combination of dipole and patch antennas: Table 1: Maximum Line of site distance between Wireless RS485 device pairs. Local Wireless device antenna Remote wireless device antenna Max distance, one pair of devices (line of sight) Max. distance, multiple pair of devices (line of sight) Dipole (supplied) Dipole (supplied) 200m Not recommended Patch Optional (stock code ) Patch Optional (stock code ) Dipole (supplied) 300m 150m Patch Optional (stock code ) 500m 250m Optional Patch Antenna to extend the range of the wireless devices. Please order Selectronic Stock code Note: Patch Antenna is directional and must be mounted in a fixed position that is directly facing the antenna of the other wireless device. IN0029 Revision 03 (005074) 4 of 15
5 Installation SP PRO, LOCAL WIRELESS RS485 DEVICE AND LOCAL KACO COMMUNICATIONS LINK (RS485) The communications link always starts at the SP PRO, then connects to all the Local KACO inverters then to the Local Wireless RS485 device in a daisy chain arrangement. There is no need to connect the local KACO inverters in any particular order. The Local Wireless RS485 device is always connected last (see fig. 4 and 5). The termination resistor is always set in the SP PRO. The termination resistor is not set in any of the KACO inverters. Fig. 4 Communications wiring for local KACO inverters and Wireless RS485 Fig. 5 Communications wiring with ONLY Wireless RS485 (no Local KACO inverters) Using the supplied CAT5 network cable, plug one end into the SP PRO RS485 port and the other end onto the RS485 wireless adaptor as shown below. If a longer cable is required then this can be any Cat 5 cable (network patch lead). If there are local KACO inverters installed then cut off the connector on one end of the CAT 5 cable from the SP PRO, strip the wires and connect the ORANGE wire (RJ45 pin 6) to the A terminal on the KACO and the ORANGE/WHITE wire (RJ45 pin 3) to the B terminal on the KACO. See table 2 below. IN0029 Revision 03 (005074) 5 of 15 POWER PERFORMANCE PASSION
6 MULTIPLE WIRELESS RS485 DEVICES AND LOCAL KACO INVERTERS This configuration is used in a Managed AC coupling system that has two or three remote wireless sites where each of these is too far apart for hard wired inter-connection. The diagram below (fig. 6) shows a system with local KACO inverters. Where no local KACO inverters are installed, connect directly from the SP PRO to the first Wireless RS485 adaptor. The intermediate adaptors use an additional plug adaptor (included) to convert the single RJ45 socket into a dual RJ45 socket. This allows standard patch leads to be used to connect between each Wireless RS485 device. NOTE: When using multiple Wireless RS485 device pairs it is recommended that Patch Antennas be used on each of the devices at the local end of the system (SP PRO end). This will reduce the interference between devices and ensure trouble free operation. Fig. 6 - Communications wiring with multiple Wireless RS485 on single phase All intermediate Wireless RS485 adaptors need to have their termination resistors set to OFF. See fig. 7 below. The last Wireless RS485 Adaptor does NOT change. Fig. 7 Setting Termination Resistor for intermediate Wireless RS485 Adaptors IN0029 Revision 03 (005074) 6 of 15
7 MULTI PHASE INSTALLATION: SP PRO, LOCAL WIRELESS RS485 DEVICE AND LOCAL KACO To incorporate the Wireless RS485 devices in a multi-phase (three phase or split phase) Managed AC coupled system, one Wireless RS485 device pair is installed per phase. In this configuration there will be one Wireless RS485 device attached to each of the SP PRO inverters and any local KACO inverters attached to that phase. At the remote end, the matching Wireless RS485 device will only be connected to the KACO inverters for that phase. NOTE: When using multiple Wireless RS485 device pairs it is recommended that Patch Antennas be used on each of the devices at the local end of the system (SP PRO end). This will reduce the interference between devices and ensure trouble free operation. Fig. 8 Communications wiring for local Wireless RS485 Adaptors in a three phase system. IN0029 Revision 03 (005074) 7 of 15 POWER PERFORMANCE PASSION
8 REMOTE WIRELESS RS485 DEVICE AND KACO INVERTERS The remote communications link always starts with the RS485 device, then connects to all the remote KACO inverters in a daisy chain arrangement. There is no need to connect the local KACO inverters in any particular order. The Local Wireless RS485 device is always connected first (see fig. 9 and 10). The termination resistor is always set in the last KACO inverter. Fig. 9 Remote Wireless RS485 and Multiple Remote Kaco inverters. Fig. 10 Remote Wireless RS485 and One Remote KACO inverter. IN0029 Revision 03 (005074) 8 of 15
9 POWER FOR THE WIRELESS RS485 DEVICES The RS485 devices are powered from the supplied plug packs. The plug packs must be connected to the same AC power circuit as the connected KACO inverters. This is normally the AC load side of the SP PRO. Fig 11 - Wireless RS485 device connections CONNECTION DETAILS FOR THE COMMS CABLES ON EACH OF THE DEVICES The following section gives detailed connection information for the SP PRO, the KACO 00 and 02 inverters and the RS485 wireless adaptor. PLEASE NOTE: The wire colours in the table 2 below may vary between different CAT5 cables. To ensure correct connections please check that the SP PRO RS485 RJ45 pins corresponds to the KACO RS485 Connector connection by buzzing out the lead before connecting it to the KACO or the SP PRO inverter. Pin 1 Fig 12 - RS485 RJ45 Adaptor Pin 1 designation IN0029 Revision 03 (005074) 9 of 15 POWER PERFORMANCE PASSION
10 SP PRO RS485 RJ45 pin Signal Typical Wire Colour (May vary with different CAT5 leads) Wireless RS485 device connector KACO xx00 Series RS485 Connector 1 GND Green/White Pin 5-2 GND Green Pin 5 - KACO xx02 Series RS485 Connector GND 3 RS485 - B Orange/White Pin 7 B B 4 GND Blue GND Blue/White RS485 - A Orange Pin 3 A A 7 GND Brown/White GND Brown Table 2 - SP PRO to Local Wireless RS485 device and Local KACO connections Note: Only the wires connected to Pins 1,2,3,and 6 (on the RJ45) are used. Connect the RJ45 connector to the SP PRO RS485 Port 2 connection Fig 13 - SP PRO Connections (inside unit) RS485 Port 2 RJ45 connector IN0029 Revision 03 (005074) 10 of 15
11 KACO Powador xx00 Series RS485 Connections Fig KACO xx00 Series RS485 Connections (inside unit) double plug in socket. On the KACO inverter there are two parallel connection sockets allowing looping through of the wiring to additional inverters. Either connection point is suitable. Green mating plugs are provided with each KACO unit included with mounting hardware plastic bag. When looped to another KACO, the termination switch position 2 should be set to OFF (away from ON). For the last KACO inverter on the Communications Link (RS485) (or when only one KACO inverter is used), the termination switch position 2 must be set to ON Fig 15 - Last KACO on Communications Link (RS485), or when only 1 KACO is used: SW 2 ON (Terminator ON) Notes: 1. Green mating connector show is provided in plastic bag with mounting hardware 2. Wire colours may vary with different CAT5 cables. 3. The Ground wire (GND) from the SP PRO RS485 communication link is not connected. IN0029 Revision 03 (005074) 11 of 15 POWER PERFORMANCE PASSION
12 KACO Powador xx02 Series Fig 16 - KACO xx02 Series RS485 Connections (inside unit) spring loaded terminals On the KACO inverter there are two parallel sets of connections allowing looping through of the wiring to additional inverters. Either connection point is suitable. When looped to another KACO, the termination switch position 1 should be set to OFF (away from ON). For the last KACO inverter on the Communications Link (RS485) (or when only one KACO inverter is used), the termination switch position 1 must be set to ON Last KACO on Communications Link (RS485), or when only 1 KACO is used: SW 1 ON (Terminator ON) Fig. 17 Fig 18 Notes: 1. Wire colours may vary with different CAT5 cables. KACO loop-through: SW 1 OFF (Terminator OFF) IN0029 Revision 03 (005074) 12 of 15
13 WIRELESS RS485 DEVICE AND REMOTE KACO COMMUNICATIONS LINK (RS485) The communications link starts at the remote Wireless RS485 device then to all the Remote KACO inverters in a daisy chain arrangement and finishes at the last Remote KACO inverter. There is no need to connect the Wireless RS485 device and the Remote KACO inverters in any particular order. The remote Wireless RS485 devices and the Remote KACO connections are detailed in the table 3 below: Signal Typical Wire Colour (May vary with different CAT5 cables) Wireless RS485 device RJ45 pinout KACO xx00 Series RS485 Connector GND Green/White Pin 1 - GND Green Pin 2 - KACO xx02 Series RS485 Connector GND RS485 - B Orange/White Pin 3 B B GND Blue GND Blue/White RS485 - A Orange Pin 6 A A GND Brown/White GND Brown Table 3 - Remote Wireless RS485 device and Remote KACO connections Configuration settings for SP PRO / KACO managed AC coupling Refer to the installation instructions IN0018 SP PRO KACO managed AC coupling installation for information on setting up and commissioning the inverters. Configuration Additional settings when using wireless. It is recommended when using wireless RS485 that Fall back power mode be programmed into the SP PRO and the KACO inverters. This is a fail safe mode that will cause the KACO inverter output power to drop to zero during a period of lost communications with the SP PRO. IN0029 Revision 03 (005074) 13 of 15 POWER PERFORMANCE PASSION
14 PROGRAMMING FALLBACK POWER INTO THE KACO POWADOR INVERTERS This section details the process for programming the KACO inverters in the system to enable fallback power mode. Details for setting the SP PRO to fallback power mode are provided in the next section. WARNING: It is important that both the SP PRO and ALL the connected KACO inverters are set to fallback Power mode to ensure correct system operation. The set fallback power mode in the KACO inverters follow the instructions below. 1. Isolate the DC solar from the KACO inverter(s) (via the appropriate DC circuit breaker). 2. Disconnect the RS485 connection from the SP PRO. The KACO parameter settings cannot be accessed when the communications link is active between the SP PRO and the KACO(s). 3. Ensuring that the SP PRO AC Load supply is present at the KACO inverter, switch on the AC supply to the KACO inverter. 4. Wake up the KACO inverter by pressing and holding the Night Switch for 10 seconds. Fig Once the display is active on the KACO, enter parameter settings mode (level 2 menu) by pressing keys 1 and 2 together. The firmware version will be displayed. Check that the firmware version is greater than or equal to the following: o ARM: V5.34 o DSP: V Press keys 1 and 2 together to return to main menu (level 1). Hold down key 2 for 20 seconds to get to the level 3 menu. Select Country is displayed 7. Keep pressing key 1 until Config. fallback power is displayed. Press key 2 to select yes. Press key 1 and the Fallback Power screen is displayed. 8. Press key 2 to change fallback power to 0000/1000 (see fig. 20). Press key 1 until Timeout setting appears. Adjust the setting to s (see fig. 21) using key 2 to change digit and key 1 to move to next digit. Fig. 20 Fig. 21 Press keys 1 and 2 together to save settings and return to main menu IN0029 Revision 03 (005074) 14 of 15
15 PROGRAMMING FALLBACK POWER INTO THE KACO POWADOR INVERTERS This section details the process for programming the SP PRO inverter in the system to enable fallback power mode. Details for setting the KACO inverters to fallback power mode are provided in the previous section. WARNING: It is important that both the SP PRO and ALL the connected KACO inverters are set to fallback Power mode to ensure correct system operation. Check that the firmware revision of the SP PRO is 7.07 or greater. Click on the Configuration Settings tab then System tab. Set the Fallback Power setting to Enable. When the configuration is complete then Save Site to file (File / Site information / save). Once the site has been saved then connect to the SP PRO using the Connect button or the Connection Menu. Once connected the configuration is sent to the SP PRO using the Configure SP PRO button in the Configuration Settings tab. Selectronic web site or contact the Selectronic Sales Team IN0029 Revision 03 (005074) 15 of 15 POWER PERFORMANCE PASSION
Installation of advanced communications board and LG Chem RESU
Installation of advanced communications board and LG Chem RESU Introduction This technical note shows how to set up an SP PRO for use with an LG Chem RESU lithium battery. It explains how to update the
More information01/09/12. WB5326 Wireless Bridge Quick Start Guide
01/09/12 WB5326 Wireless Bridge Quick Start Guide Quick Start Guide WB5326 Outdoor Wireless Bridge Items Included in Kit (1) WB5326 RADIO (1) PoE (48V, 1A) (1) Mounting Hardware Accessories (1) Quick Start
More informationPublication version 2.2 November RS485 Slave Intercoms WIRING INFORMATION
Publication version 2.2 November 2002 RS485 Slave Intercoms WIRING INFORMATION About this document The purpose of this document is to provide a complete wiring description, of the selected JACQUES product.
More informationCommBox Control Pro & Lite Hardware Manual 1.0
CommBox Control Pro & Lite Hardware Manual 1.0 Date: 16-Feb-2016 Table of Contents 1 Introduction 3 2 Ports 4 2.1 Control Pro Port Layout 4 2.2 Control Lite Port Layout 4 2.3 CEC/I2C 4 2.4 IRBUS 5 2.5
More informationBreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide
This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check
More informationA0326. ARIA Audio Streaming Source Receiver with a built in Bluetooth 4.2 Module. ARIA Audio
A0326 ARIA Audio Streaming Source Receiver with a built in Bluetooth 4.2 Module ARIA Audio by 2017 Model A0326 Channel Vision s ARIA Audio Streaming Receiver is equipped with a Blue tooth 4.2 module, users
More informationRotator Genius Instruction Manual v1.3.3
Rotator Genius Instruction Manual v1.3.3 OVERVIEW Device connection overview 4O3A Signature Rotator Genius is a smart, high integration rotator controller. It uses an electromagnetic sensor for reading
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationRAK-STAR: CAT-5 star distribution unit
RAK-STAR: CAT-5 star distribution unit Rako Wired system can be connected by Loop in/loop out wiring scheme or by Home Run scheme. In Home Wiring scheme all Wall Plates and other devices can be wired back
More informationRotator Genius Manual
Rotator Genius Manual During the time of writing the firmware and app versions are 1.4.3 Table of Contents 1. Introduction and Overview...2 2. Powering Up!...2 2.1 Buttons and Controls...3 2.2 Network
More informationDMX Downlight Driver. LDD-DMX User Manual
DMX Downlight Driver LDD-DMX 2016 Digilin Australia. Document Rev : 5. 2-4 Nov ember 2016 Product spe cifications are subject to change without no tice. Table Of Contents Safety Notes... 2 Introduction...
More informationSP PRO Communications LAN Connectivity
SP PRO Communications LAN Connectivity Introduction This application note provides information to enable the connection of an SP PRO to a Local Area Network (LAN). Information provided is targeted at persons
More informationA0326. Bluetooth 4.2 Receiver Module For Aria Audio System. ARIA Audio
A0326 Bluetooth 4.2 Receiver Module For Aria Audio System ARIA Audio by 2018 Model A0326 Channel Vision s ARIA Audio Streaming Receiver is equipped with a Blue tooth 4.2 module, users will enjoy further
More informationWash Light User Data. User Data - Specifications Date: 01/11/2016 Page 1/7. RGBW (White 4000k) Single Colour (R,G,B,A,W)
Wash Light User Data RGBW (White 4000k) Tuneable White (592nm - 6500k) Single Colour (R,G,B,A,W) RGBA (Amber 592nm) 4 Channel 4 Channel 1 Channel 4 Channel 3,360lm at source 5,352lm at source - 2,724lm
More informationALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved
ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE Version 1.0 Date: September, 2013 Copyright 2007 Altai Technologies Limited ALL RIGHTS RESERVED. Altai Technologies Limited Unit 209, 2/F, East Wing, Building
More informationWireless Area Controller (WAC60)
Installation Instructions The Daintree WAC60 Wireless Area Controller (WAC) is at the heart of the Daintree wireless controls solution for smart buildings. It provides intelligent control across a large
More informationA0326. Bluetooth 4.2 Receiver Module For Aria Audio System. ARIA Audio
A0326 Bluetooth 4.2 Receiver Module For Aria Audio System ARIA Audio by 2018 Model A0326 Channel Vision s ARIA Audio Streaming Receiver is equipped with a Blue tooth 4.2 module, users will enjoy further
More informationS1 Access Control Gateway Datasheet
S1 Access Control Gateway Datasheet Table of contents Information... 2 Technical Specifications... 2 Images... 2 Wiring and Cabling... 3 Option 1: LAN PoE (Preferred Option)... 3 Option 2: WIFI + GPO -
More informationUser Manual EzLogger WiFi Ver 02
User Manual EzLogger WiFi Ver 02 Table of Contents 1 Symbols..................................... 01 2 Safety...................................... 02 3 Installation...................................
More informationSTARTUP GUIDE SCM /SP ENGLISH
Anybus Wireless Bolt STARTUP GUIDE SCM-1202-006/SP2139 2.4 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks
More informationPVM1010 Inverter Data Monitoring Module
PVM1010 Inverter Data Monitoring Module INSTALLATION MANUAL 97-600100-15-A03 Preface PV Powered PV Powered designs, manufactures, and markets the solar power industry s most reliable photovoltaic solar
More informationLuxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F
Luxline driver LL-PCB-LUXlinedriver Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk 10200 T +32 3 293 35 50 F +32 3 293 35 44 Luxline driver - page 1 Content PCB Layout Placement Connectors Supply Wago
More information7I74 MANUAL 8 CHANNEL RS-422 INTERFACE
7I74 MANUAL 8 CHANNEL RS-422 INTERFACE V1.2 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................
More informationCAN4VSCP - RS232. Smart CAN4VSCP serial interface. Reversion
CAN4VSCP - RS232 Smart CAN4VSCP serial interface Reversion 1.0-2014-02-28 Abstract CAN4VSCP-RS22 is a very simple interface module for connecting a computers RS-232 interface to the VSCP CAN bus. The module
More informationA0362. Bluetooth 4.2 Receiver Module For Aria Audio System. ARIA Audio
A0362 Bluetooth 4.2 Receiver Module For Aria Audio System ARIA Audio by 2018 Model A0362 Channel Vision s ARIA Audio Streaming Receiver is equipped with a Blue tooth 4.2 module, users will enjoy further
More informationPOWERWISE INDAC SETUP MANUAL
POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product
More informationSPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS
SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors
More informationQD V LED Tape DMX Driver
4 320W output 1-16ch 24V 4x 5A HP SMD5050 60LED/M MP SMD3528 120LED/M SP SMD3528 60LED/M 60M 60M 20M 30M 60M 110-240VAC Input Voltage IP20 Ingress Protection 24V Output Voltage 4x 5A Max Output Current
More informationxpico Wi-Fi Embedded Device Server Evaluation Kit User Guide
xpico Wi-Fi Embedded Device Server Evaluation Kit User Guide Part Number 900-643-R Revision B July 2013 Copyright and Trademark Warranty Contacts 2013 Lantronix, Inc. All rights reserved. No part of the
More information7I44 MANUAL 8 CHANNEL RS-422 INTERFACE
7I44 MANUAL 8 CHANNEL RS-422 INTERFACE V1.1 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................
More informationFirmware/Bootloader Update Manual
UEL6000 Ethernet Firmware/Bootloader Update Manual General Remarks The only purpose of this manual is a description of the product. It must not be interpreted as a declaration of conformity for this product
More informationLGate 120 Installation Guide - Appendix
LGate 120 Installation Guide - Appendix This guide contains information on RS485 and Ethernet connections to the LGate 120 3GY Version 1.1 Table of Contents Important Product Information 3 The LGate 120
More informationNetworking Instructions Transform Motorized Acoustical Banner
Networking Instructions Transform Motorized Acoustical Banner Contents Introduction.......................................2 Networking Details.................................3 Banner Controls...................................7
More informationSquare D Clipsal Pascal Automation Controller
Square D Clipsal Pascal Automation Controller SLC5500PACA For Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal Pascal Automation Controller 63249-420-258A2 Instruction
More informationInstallation Guide: eohub and eogenius
Installation Guide: eohub and eogenius Table of Contents 1 Introduction... 2 2 Wiring Connections for the Genius Charging stations and the serial bus... 3 2.1 Fitting termination resistors to the RS485
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationSoundwebTM. Installation Guide
105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards
More informationSMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL
SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL SmartLine (Wireless) Installation Manual v1.9 1.Contents 2. Overview...2 Equipment List...2 Introduction... 2 Monitoring Software Compatibility...2
More informationMATRIX 2 Podule. Description
MATRIX 2 Podule Description Used as the heart of a distributed audio system, as the main router for a multi room system or as part of a complex boardroom system, the Ikon Matrix 2 Podule offers an easily
More informationand/or b. an optional internal Iridium satellite modem.
Appendix D Manual for Data Logger/Control Unit D.1. Introduction and Specifications D.1.1. Q DL 2100 Data logger Platform The Q DL 2100 data logger platform consists of: 1. A microcontroller containing
More information4 Channel DMX Driver Instruction Manual
LEDstuff.co.nz 4 Channel DMX Driver Instruction Manual Quality LED Lighting Products The LEDstuff 4 Channel DMX Driver is a flexible module that is an ideal addition to an existing home automation or lighting
More informationWTS BASE STATIONS USER MANUAL
WTS BASE STATIONS USER MANUAL Revision History Date Issue Author Comments Approved by 09/09/11 A JRK First Issue MAB Sheet 1 of 7 -a WTS BASE SATIONS.doc CONTENTS 1 INTRODUCTION / OVERVIEW... 2 1.1 WTS-BSI...
More informationMeter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)
Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of
More informationDigital Power Probes, ACL120, ACL220, ACL Internal, and DCL5 (#30015, #30023, #30024, #30025)
Digital Power Probes, ACL120, ACL220, ACL Internal, and DCL5 (#30015, #30023, #30024, #30025) This series of digital power probes by Networked Robotics is used to record a yes/no indication of the presence
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401
Manufacturer: DSC Integration Note Model Number(s): Power Series / 5401 Core Module Version: 4.0 (all builds) Comments: Document Revision Date: 1/30/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series
More informationIntegration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100
Manufacturer: DSC Integration Note Model Number(s): DSC POWER SERIES / IT-100 Core Module Version: 6.4.209 Comments: Document Revision Date: 9/11/2013 OVERVIEW AND SUPPORTED FEATURES The DSC Power Series
More informationProduct Data Sheet. BMS/Graphics Interface. Features
BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface
More informationRH-8 Headphone Station. Installation Guide
RH-8 Headphone Station Installation Guide 2 RH-8 Installation Guide Contents Safety Information...4 Introduction...4 What s in the Box... 5 Top view... 6 Base view... 7 Installation...8 Connections...
More informationXTS36 Touch Screen X10 Lighting Control System Operating Manual
X10 Lighting Control System Operating Manual 1 X10 Lighting Control System Operating Manual Rev 1.2 Introduction...3 Software Overview...4 How to Install...5 USB Driver Installation...6 Configuration Software
More informationxpico 110 Wired Device Server Module Evaluation Kit User Guide
xpico 110 Wired Device Server Module Evaluation Kit User Guide Part Number 900-788-R Revision A April 2017 Intellectual Property 2017 Lantronix, Inc. All rights reserved. No part of the contents of this
More informationThe TRSUN is the complete solution for the remote monitoring of photovoltaic plants.
The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system
More informationBest Installation Practices. AcquiSuite A ModHopper R9120-3
Best Installation Practices AcquiSuite A8812-1 ModHopper R9120-3 Revised 4/2/2012 Agenda General best practices guidelines Site survey best practices Installation best practices Commissioning best practices
More informationInstallation Guide: eohub and eogenius
Installation Guide: eohub and eogenius Table of Contents 1 Introduction... 2 2 Wiring Connections for the Genius Charging stations and the serial bus... 3 2.1 Fitting termination resistors to the RS485
More informationSK CU4-EIP-C Part number:
SK CU4-EIP-C Part number: 275 271 519 EtherNet/IP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationWireless Touchscreen Installation Guide
Wireless Touchscreen Installation Guide Safety Declaration of Conformity The Systemline Wireless Commander has been designed and independently tested to be in compliance with the following standards:
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationMulti-channel system install guide
www.coachsound.com Multi-channel system install guide MLA2500 Tourmaster MLS2500 Soundserver 1 HEAD UNIT... 2 1.1 Power and control signals... 2 1.2 GPS connection (MLA2500 only)... 2 1.3 Drivers control
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More informationPro10 Headset System
Pro10 Headset System Installation Manual This guide specifies how the Pro10 headset system should be installed and commissioned. The LEDs on the, registration point and headset use a sequence of colours
More informationSolarEdge 10000A-US Inverter SolarVu Installation Guide
INVERTER COM 2 D- SolarEdge 10000A-US Inverter SolarVu Installation Guide Introduction SolarVuTM is an energy portal that enables remote monitoring of renewable energy generation sites over the internet.
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More informationClockaudio ARM-C Control Box Instructions
Clockaudio ARM-C Control Box Instructions www.clockaudio.com email: info@clockaudio.co.uk Clockaudio Ltd 22 Arnside Road Waterlooville Hampshire PO7 7UP England 1 Product Guarantee Thank you for purchasing
More informationSK TU4-IOE-M12-C Part Number
SK TU4-IOE-M2-C Part Number 275 28 256 IO Extension Only qualified electricians are allowed to install and commission the module described below. An electrician is a person who, because of their technical
More informationTranslink Controller Installation Manual V1.0
Translink Controller Installation Manual V1.0 1 Contents 2 Warning... 3 3 Overview... 3 4 Packaging... 3 5 Physical Installation... 3 6 Wiring... 4 6.1 Power... 4 6.2 Ethernet... 4 6.3 C-Bus... 4 6.3.1
More informationConect 121 Upgrade. Copyright 2013 Conqueror Design and Engineering Ltd.
All rights reserved. Any dispute about the use of this software and/or hardware or of these terms and conditions shall be resolved or arbitrated under English Law. Manuals and accompanying documentation
More informationSolarVu Installation Guide For CSI-KTL-GS Three Phase Inverters
SolarVu Installation Guide For CSI-KTL-GS Three Phase Inverters Introduction SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over the internet. It requires
More informationClipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems
Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction
More informationC-Bus Four Channel Voltage Free Relay Installation Instructions
C-Bus Four Channel Voltage Free Relay Installation Instructions 5504RVF Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3
More informationContents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection
Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital
More informationSelectronic accessories to support the SelectSun 3 phase grid-tie inverter range
Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range Our all new SelectSun range of 3 phase solar inverters are equally at home with or without batteries. Available in 20kW
More informationGSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18
GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58
More informationConnection Cables for Operating Devices
Connection Cables for Operating Devices Date of creation: 05.03.2018 Version date: 06.06.2018 Article number: 12-6X0-XXX-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/06274/4321
More informationone cool inverter. GT Series Solar Inverter Quick Install Guide v1.4
one cool inverter. GT Series Solar Inverter Quick Install Guide v1.4 This quick installation guide must be used in conjunction with the Installation Manual. For installation support contact your local
More informationDL-HDM44A-H2 Quick Install Guide
DL-HDM44A-H2 Quick Install Guide This guide is for quick installation only. For complete owners manual go to www.libav.com or use a QR reader to access the manual via QR code below. Scan QR Code with your
More informationDL-HD2100 Quick Install Guide
DL-HD2100 Quick Install Guide This guide is for quick installation only. For complete owners manual go to www.libav.com or use a QR reader to access the manual via QR code below. Scan QR Code with your
More informationUSER MANUAL FOR MF0200 GATEWAY BOX VERSION 2.0
USER MANUAL FOR MF0200 GATEWAY BOX VERSION 2.0 COPYRIGHT & TRADEMARKS 2016 Mentor Graphics Corporation, all rights reserved. This document contains information that is proprietary to Mentor Graphics Corporation
More informationHigh Power (15W + 15W) Stereo Amplifier
High Power (15W + 15W) Stereo Amplifier Build Instructions Issue 1.0 Build Instructions Before you put any components in the board or pick up the soldering iron, just take a look at the Printed Circuit
More informationAI-102. IR Illuminator. Installation Guide. Rev IP Surveillance
AI-102 IR Illuminator Installation Guide Rev. 1.1 IP Surveillance Revision History: Rev. 1.0: Initial release Rev. 1.1: Changed effective IR range and power consumption. AI-102 Tube Type Infrared Illuminator
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More informationTEAM DIGITAL. CSCe Central Signal Controller
TEAM DIGITAL Improving the world of DCC CSCe Central Signal Controller > Control signals on your layout > Compatible with the SHD2 > 6 inputs for sensors/switches > 6 outputs to drive LEDs > 2 outputs
More informationLinked. Integration requirements and instructions for controls systems
Linked Integration requirements and instructions for controls systems 2010, NL-INT 04/01/10 Relay Information... Three additional relays are required for the NOVALinked option to work properly with a control
More informationQuick Start Guide. GV-Video Server. 1 Introduction. Packing List
Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video
More informationRS RS-485 INTERFACE CONVERTER IC-485S & IC-485SI. User s Manual
RS-232 - RS-485 INTERFACE CONVERTER IC-485S & IC-485SI User s Manual @Copyright 1994 ATEN@ International CO., LTD. Manual part NO.PAPE-0075-200 Printed in Taiwan 06/94 PACKAGE CHECKLIST When you purchase
More informationCLS LDV-45. CLS Atmosphere LED-panel CLS LDV-45
INTRODUCTION The is a DMX controllable LED dimmer, which has a maximum of 4 regulated voltage DC outputs. Up to a maximum of 5A per channel at 2-24 Volts, with a total maximum current of 0A. Equipped with
More informationINSTALLATION AND COMMISSIONING CHECKLIST
Installation environment Ensure installation site meets environmental and physical constraints. [ ] Good [ ] Poor 2 Unpacking Check inverter condition after unpacking. [ ] Good [ ] Poor 3 Mounting bracket
More informationSTD Simple Telemetry Application. Owner s Manual
STD47 1.0 Simple Telemetry Application Owner s Manual Table of Content 1. Safety Information... 4 2. Main Functions:... 5 2.1. Start-Up alarm message... 5 2.2. Digital Output control:... 5 2.3. Digital
More informationFVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL
2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital
More informationSolarVu Installation Guide for Sungrow SG60KU-M Inverter
TM SolarVu Installation Guide for Sungrow SG60KU-M Inverter Introduction TM SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over the internet. It requires
More informationFronius Firmware Update Configuration
Fronius Firmware Update Configuration Introduction This document outlines the procedure to configure the Voltage Dependent Power Reduction, Soft Start, the Power Change Gradient and the Frequency Dependent
More informationSECIO 64/128/192 User Manual
SECIO 64/128/192 User Manual Help Version updated until firmware 404v Copyright 2013, AKCess Pro Co., Ltd.. What is the SECIO? SECIO Product Manual The SECIO is an Input or Output device with 64, 128 or
More informationFPA-1 Facility Port Adapter Installation Guide
FPA- Facility Port Adapter Installation Guide FPA- Installation Guide v. Contents Introduction... 3 Mounting - mechanical... 4 Connections and Controls... 5 Block Diagram... Installation connections...
More informationNanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ
NanoServ Thin System/Ultra-Thin System Setup Guide 1.0 What s included with the NanoServ The following items are included with the NanoServ : 1. NanoServ 2. AC Power Adaptor 3. CD-ROM with User s Manual
More informationPower & Communication Cables
Power & Communication Cables CBLSM-M & CBLSM-X series is the main power and communications cable consisting of a 7W main motor connector split out to a pre-wired RS- DB- connector to plug directly into
More informationTHIS PAGE LEFT BLANK
SOUND LEVEL LIMITER THIS PAGE LEFT BLANK IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. The must be installed
More informationUsing solderless breadboards
Page 1 of 9 Using solderless breadboards This document describes how to use the solderless breadboards available in the experimental didactic lab (LED, previously LADISPE) of Politecnico di Torino. 1 Setting
More informationSK CU4-ECT-C Part number:
SK CU4-ECT-C Part number: 275 271 517 EtherCAT Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationAllen-Bradley Drives
Installation Data This document provides information on: important pre installation considerations power supply requirements installing the module installing and connecting the wiring using the module
More information2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM
2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM CONTENTS PAGE Manual Introduction 3 Product Overview 3 Operation and Connection 3 RS232 Connection 3-4 RS485 Connection 3-4 2214 PCB layout 5 RS485 Bus Terminal
More informationgridcomm GC1310 Master Light Controller Hardware Installation Guide
gridcomm GC1310 Master Light Controller Hardware Installation Guide GC1310 GC1318 Non LoRA option LoRA option GridComm Pte. Ltd. Page 1 of 16 GC-Net and the gridcomm logo are trademarks of gridcomm Pte
More informationAC Power Probe, ACL1 (#30015)
AC Power Probe, ACL1 (#30015) The Networked Robotics ACL1 power probe is designed to be used as part of the Tempurity System for collecting and monitoring data through computer networks. The ACL1 enables
More information