TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)

Size: px
Start display at page:

Download "TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)"

Transcription

1 Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The arrow to the right marks the selection available. Make one selection per table, using the column below the proper arrow. A dot denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table III. Key Number I II III _ - - _ - _ KEY NUMBER Selection Availability Description 7082 Analyzer TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Range Power Output 0-1 V & 0-10 V 13 Wide Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 14 None 15 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 16 Power Plant Function 0-1 V & 0-10 V 17 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 18 None V & 0-10 V 4-20 ma 22 Wide Range - Dual Cell 120/240 VAC Two 4-20 ma 23 Three 4-20 ma 24 None V & 0-10 V 4-20 ma 26 Standard Range - Dual Cell 120/240 VAC None 27 Two 4-20 ma 28 Three 4-20 ma 29 Table I continued on following page

2 Page 2 of TABLE I (continued) Selection RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Range Power Output Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 72 None 82 Wide Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 73 Standard Range - Dual Cell 120/240 VAC Two 4-20 ma 74 None 83 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 81 Power Plant Function INPUT, POWER, OUTPUT (ph/orp MEASUREMENTS) Input Power Output 0-1 V & 0-10 V V & 0-10 V 4-20 ma 11 ph from External Preamp 120/240 VAC None 12 Two 4-20 ma 20 Three 4-20 ma 21 Direct Glass/Antimony ph/orp 0-1 V & 0-10 V 30 Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 31 None 32 Direct DURAFET ph Electrode, 120/240 VAC 0-1 V & 0-10 V 4-20 ma 41 Internal Preamp ph from External Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 70 None 77 Two 4-20 ma 78 Direct Glass/Antimony ph/orp Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 71 None 80 Direct DURAFET ph Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma to 1990 X 10 PPB or PPM 120/240 VAC 0-1 V & 0-10 V 4-20 ma to 1990 X 10 PPB or PPM 120/240 VAC 0-1 V & 0-10 V 4-20 ma 75

3 Page 3 of 5 TABLE II OPTIONS Tagging None Linen Customer I.D. Tag Limit to 3 lines, 22 spaces per line Selection 0 1 Stainless Steel Customer I.D. Tag 2 Limit to 3 lines, 22 spaces per line Power Standard Factory Setting _ 0 _ Factory Set 240 Volt Operation _ 1 _ None 0 Additional Output Relays Two Additional Output Relays 1 b (analyzer comes with a total of 4 relays but no outputs) Two Additional Output Relays, 2 b Hermetically Sealed, (analyzer comes with a total of 4 relays and a 0-1V, 0-10V, or 4-20mA output) Future None _ 0 _ Future None 0 TABLE III Factory Use Only None 000 RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection b I 12, 25, 27, 32 Notes: 1 Panel mounting hardware included. For pipe mounting kit order part number separately. 2 To mount 7082 in existing 7070, 7075 or 7076 panel cutout, order filler plate kit, part number separately. 3 ph Models , 12, 20, 21, 51 and 52 can be field converted to direct electrode input by ordering a separate internal preamp for glass or Durafet electrodes: Glass/Antimony or ORP internal preamp - part number Durafet internal preamp - part number For simultaneous ph/orp measurements (not with Durafet electrodes) see electrode Model Selection Guides for proper mounting selections.

4 Page 4 of 5 Accessories and Replacement Parts Kit/Part Number Description Parts included in Kit Quantity PARTS COMMON TO ALL 7082 ANALYZERS Miscellaneous parts for all volt fuse 1 controller/analyzers 240 volt fuse 1 24 volt fuse 1 case gasket 1 circuit card retainer bracket 1 plastic hinge 3 retainer screw 1 ground screw Power line filter kit filter cores Panel mounting kit bracket Pipe mounting kit U-bolt for 1 inch pipe 1 U-bolt for 2 inch pipe Reducer panel kit Output card: single current or voltage card 1 output Output card: single current or voltage card 1 output with two additional hermetically sealed relays Output card: two additional general card 1 purpose relays and no analog outputs For replacement of existing card on ph/ card 1 conductivity analyzer: 2 current outputs For replacement of existing card on ph/ card 1 conductivity analyzer: 3 current outputs PARTS USED BY CONDUCTIVITY 7082 ANALYZERS ONLY For upgrade of conductivity analyzer card 1 Wide range: 2 current outputs prom For upgrade of conductivity analyzer card 1 Standard range analyzer: 2 current outputs prom For upgrade of conductivity analyzer card 1 Wide range analyzer: 3 current outputs prom For upgrade of conductivity analyzer card 1 Standard range analyzer: 3 current outputs prom Replacement conductivity standard range card 1 input card Replacement conductivity wide range card 1 input card Conductivity bezel assembly assembly 1 legend set Conductivity LCD display assembly 1

5 Page 5 of 5 Accessories and Replacement Parts Kit/Part Number Description Parts included in Kit Quantity PARTS USED BY ph/orp 7082 ANALYZER ONLY ph bezel assembly assembly, 1 legend set, 1 key legend ph LCD display assembly Internal preamp for use with glass/orp preamp 1 mounting rivets Internal preamp for use with Durafet preamp 1 mounting rivets For upgrade of ph analyzer card 1 Output Card: 2 current outputs prom For upgrade of ph analyzer card 1 Output card: 3 current otuputs prom Replacement ph input card card 1 PARTS FOR WITHDRAWN 7082 ANALYZERS Output card: single current or voltage card 1 output for 24 volt 7082 ph and conductivity units Output card: voltage only for units card Output card: CE voltage and current for card 1 single cell 7082 conductivity units Output card: two current outputs for 24 volt card 1 ph and conductivity 7082 units Battery kit for single cell 7082 conductivity battery 1 units jumpers 3 retainer Power supply PWA for 24 volt ph and assembly 1 conductivity Input card: single cell 7082 conductivity card 1 units preamp-to-instrument cable for , , -50, -70, and -90, and all 7777 mountings ft length with quick disconnect and cable ft length with quick disconnect and cable ft length with quick disconnect and cable ft length with quick disconnect and cable 1 pre-amp-to-instrument cables for , 05, , -12, -50, -52, -60, -62, and , 60, -80 mountings Six-conductor cable (specify length) cable 1

Description, continued

Description, continued DL424/425 DirectLine Sensor Module for DL5000 Dissolved Oxygen Probes Overview 70-82-03-48 4/02 Page of 8 Specification The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics

More information

SIGNET 5700 ph/orp Monitor - ORP Instructions

SIGNET 5700 ph/orp Monitor - ORP Instructions SIGNET 5700 ph/orp Monitor ORP Instructions ENGLISH 35700.0901 H (6/01) English CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections. Follow

More information

SEL-2411 Programmable Automation Controller

SEL-2411 Programmable Automation Controller SEL-2411 Programmable Automation Controller - Chassis - Processor and Communications Board - Front Panel - EIA-232 Port - LCD Display - IRIG-B Time Code - Operator Control Interface - Power Supply with

More information

APS SCALE SERIES DIMENSIONS

APS SCALE SERIES DIMENSIONS APS SCALE SERIES DIMENSIONS 4300 Section page 4 Model APS4300 Recommended Column/Base Combinations 14 Atlas Column 20 Atlas Column 30 Atlas Column Atlas Scale Series Dimensions: 4300 OPTIONS 4300 Section

More information

Electronics. Plate 1.1 MPD -1 Computer Display Module Three-Grade, Four-Grade, and Fixed Blender F F

Electronics. Plate 1.1 MPD -1 Computer Display Module Three-Grade, Four-Grade, and Fixed Blender F F Plate. MPD - Computer Display Module Three-Grade, Four-Grade, and Fixed Blender 3 5 2 2 3 F 5 6 F2 7 8 9 0 7 6 8 9 7 0 5 3 6 2 8 Page 0 PT-80 MPD Series Illustrated Parts Manual /93 Housing, Black T6037-G2S6

More information

NN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3.

NN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3. 0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer For detailed instructions see UDA Universal Dual Analyzer Product Manual 0---. Step. Model Number Interpretation Write your analyzer model

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

53MC5 53IT5 53ML5 53SL5

53MC5 53IT5 53ML5 53SL5 Main Processor Boards 686B608U01* 53MC5000A single loop, standard functionality OBSOLETE - order 614C189U01 686B608U02 53MC5000A two loop, standard functionality OBSOLETE - order 614C189U02 686B608U03

More information

SEL-2414 Transformer Monitor

SEL-2414 Transformer Monitor SEL-2414 Transformer Monitor SEL-2414 Base Unit Vertical Chassis Front Panel Large LCD Display 4 Programmable Pushbuttons w/leds 7 Programmable LEDs Operator Control Interface EIA-232 Port Processor and

More information

2015 List Prices AquaMaster 120V Lighting for Competitor Fountains

2015 List Prices AquaMaster 120V Lighting for Competitor Fountains Step 1: Select Light Set Step 2a: 13 & 35W Select Lens Assembly Step 2b: 22W ONLY Select Color Board Assembly Step 3: Select 50ft. Cable Assembly (must Select to keep UL, CE and warranty valid) Step 4:

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount NEW! Modbus Module supports RS485 Serial Modbus Communications Multiple sensor types supported with

More information

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS

SEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS Spec-224 Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E61997 NEMA/EEMAC Type 12 CSA

More information

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Spare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders

Spare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders PARTS LIST No. PL/RC-001 Date January 2004 Product SM1000 and SM2000 Videographic Recorders Spare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders This parts list contains:

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997

More information

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12

UL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12 Spec-224 SEQUESTR Preferred-Cutout isconnects SEQUESTR External isconnects Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per

More information

Signet 5700 ph/orp Monitor - ph Instructions

Signet 5700 ph/orp Monitor - ph Instructions Signet 5700 ph/orp Monitor ph Instructions English *35700.0901* 35700.0901 Rev. K 3/06 English/pH CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output

More information

+GF+ SIGNET ph/orp Transmitter Instructions

+GF+ SIGNET ph/orp Transmitter Instructions GF SIGNET 8750 ph/orp Transmitter Instructions ENGLISH 8750.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

1/6 STAINLESS STEEL SBC DIG. 316 SENSE AUDIO ENT.PAN. 3ONE6 DOOR ENTRY SYSTEMS OVERVIEW 3451AS

1/6 STAINLESS STEEL SBC DIG. 316 SENSE AUDIO ENT.PAN. 3ONE6 DOOR ENTRY SYSTEMS OVERVIEW 3451AS 1/6 OVERVIEW Flush-mounted entrance panel (fitted level with the wall) and 3 mm thick stainless steel plate. Certified as IK08. Complete with 128x64 dot LCD graphic display and 15 buttons integrated into

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand

More information

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*

Power Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory* SEL-734 Advanced Metering System with ANSI and IEC Class 0.2 Accuracy Standard with: ANSI Type 2 Optical Port, 2 Rear EIA-232 Ports, ACSELERATOR QuickSet SEL-5030 Software, Modbus RTU Communications Protocol,

More information

SM2000 Videographic recorder Spare parts and upgrade kits

SM2000 Videographic recorder Spare parts and upgrade kits ABB MEASUREMENT & ANALYTICS PARTS LIST SM2000 Videographic recorder Spare parts and upgrade kits Measurement made easy Sales Service Introduction This parts list contains: exploded diagrams of the SM2000

More information

BA684DF-P PROFIBUS PA Field mounting Fieldbus Display

BA684DF-P PROFIBUS PA Field mounting Fieldbus Display BA684DF-P PROFIBUS PA Field mounting Fieldbus Display Issue: 3 Issue: 3 8 th December 2011 2 CONTENTS 1. Description 1.1 Documentation 1.2 Version 3.0 firmware 2. Operation 2.1 Controls 3. System Design

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

770MAX Multiparameter Analyzer/Transmitter Instruction Manual

770MAX Multiparameter Analyzer/Transmitter Instruction Manual Part No. 84372 770MAX Multiparameter Analyzer/Transmitter Instruction Manual Mettler-Toledo Thornton, Inc. 2007 No part of this manual may be reproduced or transmitted in any form or by any means, electronic

More information

SM1000 Videographic recorder Spare parts and upgrade kits

SM1000 Videographic recorder Spare parts and upgrade kits ABB MEASUREMENT & ANALYTICS PARTS LIST SM1000 Videographic recorder Spare parts and upgrade kits Measurement made easy Sales Service Introduction This parts list contains: exploded diagrams of the SM1000

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,

More information

TB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications

TB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications Data sheet DS/TB84TE EN Rev. C TB84TE Conductivity transmitter 2-Electrode Superior accuracy in low conductivity and pure water applications Smart key menu programming Superior accuracy in low conductivity

More information

AllPro Hazardous/Corrosive Area Fluorescent

AllPro Hazardous/Corrosive Area Fluorescent CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - 4X UL 844 - Class I Div. 2 - Groups A, B, C, & D UL 4X UL - Outdoor

More information

Tongue Switches Trojan 5 & 6

Tongue Switches Trojan 5 & 6 Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key

More information

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.

See also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM. Spec-224 H763.422.2211 763.422.26 SEQUESTR Preferred-Cutout s SEQUESTR External s SEQUESTR Preferred-Cutout s SEQUESTR External s SEQUESTR External Package, Type 12 FEATURES INUSTRY STANARS UL 58A Listed;

More information

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

BXD17 Series. Features. Analytical instrumentation for your measurement applications. BXD17 Series Analytical instrumentation for your measurement applications. Features Single parameter instrument with temperature measurement capabilities Custom IP66 NEMA 4X (144 x 144mm) enclosure Versatile

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

ABB Automation. Advantage Series ph/orp/pion Analyzer. Type TB84pH. Specification. Simple menu programming (patent pending).

ABB Automation. Advantage Series ph/orp/pion Analyzer. Type TB84pH. Specification. Simple menu programming (patent pending). Type TB84pH Advantage Series ph/orp/pion Analyzer Specification Simple menu programming (patent pending). Online continuous sensor diagnostics. Two fully programmable isolated outputs: Zero to 20 ma and

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

Analog Output Module Installation Instructions

Analog Output Module Installation Instructions Description The Analog Output Module is a component of Novar Controls Spectrum Refrigeration Control System. It produces a varying analog voltage signal to control proportional modulating devices. Control

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Conductivity Transmitters

Conductivity Transmitters Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows

More information

770MAX Multiparameter Analyzer/Transmitter. Instruction Manual

770MAX Multiparameter Analyzer/Transmitter. Instruction Manual THORNTON Leading Pure Water Analytics Part No. 84372 770MAX Multiparameter Analyzer/Transmitter Instruction Manual IMPORTANT SAFETY INFORMATION Follow all warnings, cautions, and instructions indicated

More information

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer Thermo Scientific AquaPro provides accurate, user-friendly in-line monitoring of process applications from power generation to municipal

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

VCM Systems Vehicle Control Module Systems

VCM Systems Vehicle Control Module Systems VCM Systems Vehicle Control Module Systems Technical Manual VCMS-SC (Standard Configuration) Switch Panel System The Model VCMS-SC Switch Panel System is a standard configuration of the VCMS product family

More information

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended

More information

Signet 5700 ph/orp Monitor - ORP Instructions

Signet 5700 ph/orp Monitor - ORP Instructions Signet 5700 ph/ Monitor Instructions English *5700.0901* 5700.0901 Rev. K /06 English/ Contents 1. Power Connections. Compatible Electrode/Preamp Wiring. 4 0 ma Current Output Connections 4. Relay Connections

More information

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9 100Led 760 / SixVac 801 / 760 / 2c 801 Micro INSTRUCTION MANUAL Digivac 760 Series Models 100Led 760 100P / 760 100P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro Ranges 0 to 760 Torr 0 to 19.99 Torr 0 to 29.9 inches of mercury The Digivac

More information

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units

More information

Signet ph/orp Transmitter * *

Signet ph/orp Transmitter * * Loop 7 6 5 Signet 8750- ph/orp *-8750.090-* CAUTION! Contents 0.0 ph 5.0C Signet ph/orp. Installation. Panel Installation gasket panel terminals mounting bracket 96 mm (.8 in.) 8050 8 mm (. in.) Optional

More information

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4 763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless

More information

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects 763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH

More information

Panel Mount Tachometer, T6

Panel Mount Tachometer, T6 Model T6, Panel Mount Tachometer Features Front programmable Field adjustable parameters Programmable Scaling and Decimal Points 4-20ma Output Signal - Internally Powered by the T6 or Externally Powered

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com S: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3 Chapter Page 1 Introduction 1 1.1 Introduction 1 1.2 Front Panel Description 2 1.3 Rear Panel Description 3 Table of Contents 2 Installation and Operation 4 2.1 Mounting Instructions 4 2.2 Power Connections

More information

Pixus Technologies Catalog

Pixus Technologies Catalog The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 96.524.8242 CAN: 59.885.5775 Product Diversity

More information

Solutions to the Most Challenging Environments

Solutions to the Most Challenging Environments Solutions to the Most Challenging Environments Short Catalog Feb, 2017 AM-2300 Multi-Input, Multi-Parameter Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity,

More information

Control Units Ex e in Stainless Steel LCS*.*

Control Units Ex e in Stainless Steel LCS*.* Features Assembly Stainless steel enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de and Ex tb Up to 4 operators per control unit, base-mounted contact blocks Wide choice of operators,

More information

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated s Flow Meters & Controls ECO FLOMAG i M A G S e r i e s o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal

More information

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects

Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects Spec-01054 Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects Free-Stand Disconnect with Quick-Release Continuous Hinge, Type 4 APPLICATION Simple, heavy-duty with easy door removal

More information

Bulletin 800Z Zero-Force Touch Buttons

Bulletin 800Z Zero-Force Touch Buttons Bulletin 800Z Zero-Force Touch Buttons IEC and NEMA Style General Purpose Range Heavy Industrial Range Protection Class 4/4X/3 and 4/3 IP66 Internationally Rated Ergonomically Designed Touch Buttons Table

More information

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition). PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council

More information

Table of Contents. 1.1 General System Features Instrument Specifications Performance Specifications 12

Table of Contents. 1.1 General System Features Instrument Specifications Performance Specifications 12 Table of Contents Part 1 Part 2 Part 3 Part 4 Part 5 Introduction 1.1 General 5 1.2 System Features 7 1.3 Instrument Specifications 9 1.4 Performance Specifications 12 Mounting 2.1 General Mounting 13

More information

Model Selection Guide 250mm Strip Chart Recorder with Price Data

Model Selection Guide 250mm Strip Chart Recorder with Price Data Page: DPR-29 DPR250 Recorder Model Selection Guide 250mm Strip Chart Recorder with Price Data Model Selection Guide 43-DR-16-19 Issue 10 Instructions Select the desired Key Number. The arrow to the right

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET TB84PH ph /ORP / pion transmitter 2 TB 8 4PH P H /ORP / P I ON TR AN S MIT TE R DS/ TB8 4PH-E N RE V. D Measurement made easy Hazardous area rated transmitter with

More information

Lift Truck Parts Professionals

Lift Truck Parts Professionals SB Connector 50 Amp Series connectors Housing w/springs Anderson Brad Anderson & contacts Wire AWG Part # Harrison # Part # Original # Gray 50 amp #6 69 900 000 7-70-P 000 7-70 #0/# 69G 90 000 7-7-P 000

More information

Specifications. Description TABLE OF CONTENTS. Page. Description 2. Specifications 2 3. Additional Options 3. How to Order 4 5

Specifications. Description TABLE OF CONTENTS. Page. Description 2. Specifications 2 3. Additional Options 3. How to Order 4 5 TABLE OF CTENTS Page Description Specifications Additional Options How to Order Circuit Descriptions Dimensions 0 Icons into the body of the switch; mounting hardware or special tools are not necessary.

More information

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work

More information

Type NT and Type ZWM Terminal Blocks

Type NT and Type ZWM Terminal Blocks Type NT and Type ZWM Terminal Blocks Unit-pole construction Sliding link to permit testing without disturbing wiring High barriers that prevent shorting between poles Class 1E qualified per IEEE RECOGNIZED

More information

eztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary.

eztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary. Datasheet -- Representative photograph, actual product appearance may vary. Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell

More information

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated s Flow Meters & Controls ECO FLOMAG imag Series o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved

More information

PS-4100 POWER SUPPLY MANUAL

PS-4100 POWER SUPPLY MANUAL PS-4100 POWER SUPPLY MANUAL Manual Part Number 180-0573 December 7, 2006 TABLE OF CONTENTS TITLE PAGE Table of Contents... 2 List Of Figures... 3 1. Introduction... 4 1.0. General... 4 1.1. Features...

More information

Standard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Standard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects Spec-00251 Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 SPECIFICATIONS 11 gauge steel (.121 inch) Seams continuously welded

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

Effective May 2018 Supersedes October 2017

Effective May 2018 Supersedes October 2017 Technical Data TD280028EN Supersedes October 2017 COOPER POWER SERIES NOVA NX-T Recloser, Form 6 NX-T, and Form 6LS NX-TRecloser Control and Accessories Ordering Guide Eaton provides reliable, economical

More information

APS2200CW SCALE SERIES DIMENSIONS

APS2200CW SCALE SERIES DIMENSIONS 2200CW Section page 4 APS2200CW SCALE SERIES DIMENSIONS Model APS2200CW Recommended Column/Base Combinations 14" Column standard for these base sizes: 20" Column standard for these base sizes: 30" Column

More information

Contents. 1. Installation

Contents. 1. Installation ENGLISH 8750.090 C/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifications. Electrical

More information

EcoFlex LED Neon Manual

EcoFlex LED Neon Manual Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of

More information

imag-series Flanged Magmeter

imag-series Flanged Magmeter s Flow Meters & Controls imag-series o M o vi n g P a r t N FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved (3 only) IP68 rated 9001:2008 ISO

More information

Brasch Washdown Unit Heaters

Brasch Washdown Unit Heaters Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt

More information

T80 Universal Transmitter S80 Intelligent Sensors

T80 Universal Transmitter S80 Intelligent Sensors T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific

More information

High Density Connectors Multipin and MS Multipin MS High Current and High Voltage

High Density Connectors Multipin and MS Multipin MS High Current and High Voltage Multipin is the description for electrical feedthroughs which have two or more conductor paths, and include connectors for one or both sides. This series is typically used for transmission of low power

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

Control and automatic dosing

Control and automatic dosing Control and automatic dosing For public and residential pools Control Basic and Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control

More information

Thetford Corp. Refrigerator Replacement Parts List

Thetford Corp. Refrigerator Replacement Parts List Thetford Corp. Refrigerator Replacement Parts List NE SERIES NE SERIES NE SERIES NE.F NE.F NE.F Part No. 677 NORCOLD /8/08 Cabinet Area - Front View - NE 7 6 6 0 9 8 ART 0 NO. PART # DESCRIPTION NE.F 670

More information

200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics

200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics THORNTON Leading Pure Water Analytics - NIST Traceable Calibration - Two Analog Outputs Standard - Three-Wire Temperature Measurement - Wide Range of Sensor and Cable Selections 200CRS Single-Channel Conductivity/Resistivity

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Analytical Instruments Two-Wire ph, ORP, plon Transmitters Data Sheet Analytical Instruments Two-Wire ph, ORP, plon Transmitters Model TB82PH Series Designed With the Real World in Mind Easy to use menus guide the operator through set-up, calibration and maintenance

More information

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.

EMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding. Spec-00418 E763.422.2211 763.422.2600 PROLINE External Components PROLINE Doors, Covers and Sides PROLINE External Components PROLINE Doors, Covers and Sides Door Gasketing, Shielding and Door Bars Overview

More information

MAG. ECO FLO imag Series NSF FEATURES

MAG. ECO FLO imag Series NSF FEATURES Flow Meters & Controls MAG ECO FLO imag Series M o vi n g P s N o rt w U NSF o n Easy setup Minimal straight pipe Mounted or remote rate & total 4-2mA output available Tamper-evident seal NSF-61 approved

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Inverter Selection Guide

Inverter Selection Guide Inverter Selection Guide KB Electronics, Inc. Chassis / IP20 models include Motor Filters to eliminate winding and bearing failures. Hybrid Drives are digital drives with an analog interface. Digital models

More information