1 Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The arrow to the right marks the selection available. Make one selection per table, using the column below the proper arrow. A dot denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table III. Key Number I II III _ - - _ - _ KEY NUMBER Selection Availability Description 7082 Analyzer TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Range Power Output 0-1 V & 0-10 V 13 Wide Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 14 None 15 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 16 Power Plant Function 0-1 V & 0-10 V 17 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 18 None V & 0-10 V 4-20 ma 22 Wide Range - Dual Cell 120/240 VAC Two 4-20 ma 23 Three 4-20 ma 24 None V & 0-10 V 4-20 ma 26 Standard Range - Dual Cell 120/240 VAC None 27 Two 4-20 ma 28 Three 4-20 ma 29 Table I continued on following page
2 Page 2 of TABLE I (continued) Selection RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Range Power Output Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 72 None 82 Wide Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 73 Standard Range - Dual Cell 120/240 VAC Two 4-20 ma 74 None 83 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 81 Power Plant Function INPUT, POWER, OUTPUT (ph/orp MEASUREMENTS) Input Power Output 0-1 V & 0-10 V V & 0-10 V 4-20 ma 11 ph from External Preamp 120/240 VAC None 12 Two 4-20 ma 20 Three 4-20 ma 21 Direct Glass/Antimony ph/orp 0-1 V & 0-10 V 30 Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 31 None 32 Direct DURAFET ph Electrode, 120/240 VAC 0-1 V & 0-10 V 4-20 ma 41 Internal Preamp ph from External Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 70 None 77 Two 4-20 ma 78 Direct Glass/Antimony ph/orp Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 71 None 80 Direct DURAFET ph Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma to 1990 X 10 PPB or PPM 120/240 VAC 0-1 V & 0-10 V 4-20 ma to 1990 X 10 PPB or PPM 120/240 VAC 0-1 V & 0-10 V 4-20 ma 75
3 Page 3 of 5 TABLE II OPTIONS Tagging None Linen Customer I.D. Tag Limit to 3 lines, 22 spaces per line Selection 0 1 Stainless Steel Customer I.D. Tag 2 Limit to 3 lines, 22 spaces per line Power Standard Factory Setting _ 0 _ Factory Set 240 Volt Operation _ 1 _ None 0 Additional Output Relays Two Additional Output Relays 1 b (analyzer comes with a total of 4 relays but no outputs) Two Additional Output Relays, 2 b Hermetically Sealed, (analyzer comes with a total of 4 relays and a 0-1V, 0-10V, or 4-20mA output) Future None _ 0 _ Future None 0 TABLE III Factory Use Only None 000 RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection b I 12, 25, 27, 32 Notes: 1 Panel mounting hardware included. For pipe mounting kit order part number separately. 2 To mount 7082 in existing 7070, 7075 or 7076 panel cutout, order filler plate kit, part number separately. 3 ph Models , 12, 20, 21, 51 and 52 can be field converted to direct electrode input by ordering a separate internal preamp for glass or Durafet electrodes: Glass/Antimony or ORP internal preamp - part number Durafet internal preamp - part number For simultaneous ph/orp measurements (not with Durafet electrodes) see electrode Model Selection Guides for proper mounting selections.
4 Page 4 of 5 Accessories and Replacement Parts Kit/Part Number Description Parts included in Kit Quantity PARTS COMMON TO ALL 7082 ANALYZERS Miscellaneous parts for all volt fuse 1 controller/analyzers 240 volt fuse 1 24 volt fuse 1 case gasket 1 circuit card retainer bracket 1 plastic hinge 3 retainer screw 1 ground screw Power line filter kit filter cores Panel mounting kit bracket Pipe mounting kit U-bolt for 1 inch pipe 1 U-bolt for 2 inch pipe Reducer panel kit Output card: single current or voltage card 1 output Output card: single current or voltage card 1 output with two additional hermetically sealed relays Output card: two additional general card 1 purpose relays and no analog outputs For replacement of existing card on ph/ card 1 conductivity analyzer: 2 current outputs For replacement of existing card on ph/ card 1 conductivity analyzer: 3 current outputs PARTS USED BY CONDUCTIVITY 7082 ANALYZERS ONLY For upgrade of conductivity analyzer card 1 Wide range: 2 current outputs prom For upgrade of conductivity analyzer card 1 Standard range analyzer: 2 current outputs prom For upgrade of conductivity analyzer card 1 Wide range analyzer: 3 current outputs prom For upgrade of conductivity analyzer card 1 Standard range analyzer: 3 current outputs prom Replacement conductivity standard range card 1 input card Replacement conductivity wide range card 1 input card Conductivity bezel assembly assembly 1 legend set Conductivity LCD display assembly 1
5 Page 5 of 5 Accessories and Replacement Parts Kit/Part Number Description Parts included in Kit Quantity PARTS USED BY ph/orp 7082 ANALYZER ONLY ph bezel assembly assembly, 1 legend set, 1 key legend ph LCD display assembly Internal preamp for use with glass/orp preamp 1 mounting rivets Internal preamp for use with Durafet preamp 1 mounting rivets For upgrade of ph analyzer card 1 Output Card: 2 current outputs prom For upgrade of ph analyzer card 1 Output card: 3 current otuputs prom Replacement ph input card card 1 PARTS FOR WITHDRAWN 7082 ANALYZERS Output card: single current or voltage card 1 output for 24 volt 7082 ph and conductivity units Output card: voltage only for units card Output card: CE voltage and current for card 1 single cell 7082 conductivity units Output card: two current outputs for 24 volt card 1 ph and conductivity 7082 units Battery kit for single cell 7082 conductivity battery 1 units jumpers 3 retainer Power supply PWA for 24 volt ph and assembly 1 conductivity Input card: single cell 7082 conductivity card 1 units preamp-to-instrument cable for , , -50, -70, and -90, and all 7777 mountings ft length with quick disconnect and cable ft length with quick disconnect and cable ft length with quick disconnect and cable ft length with quick disconnect and cable 1 pre-amp-to-instrument cables for , 05, , -12, -50, -52, -60, -62, and , 60, -80 mountings Six-conductor cable (specify length) cable 1
Description, continued
DL424/425 DirectLine Sensor Module for DL5000 Dissolved Oxygen Probes Overview 70-82-03-48 4/02 Page of 8 Specification The DirectLine DL424/425 Sensor Modules are part of a family of products developed
More informationLAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics
More informationSIGNET 5700 ph/orp Monitor - ORP Instructions
SIGNET 5700 ph/orp Monitor ORP Instructions ENGLISH 35700.0901 H (6/01) English CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output connections. Follow
More informationSEL-2411 Programmable Automation Controller
SEL-2411 Programmable Automation Controller - Chassis - Processor and Communications Board - Front Panel - EIA-232 Port - LCD Display - IRIG-B Time Code - Operator Control Interface - Power Supply with
More informationAPS SCALE SERIES DIMENSIONS
APS SCALE SERIES DIMENSIONS 4300 Section page 4 Model APS4300 Recommended Column/Base Combinations 14 Atlas Column 20 Atlas Column 30 Atlas Column Atlas Scale Series Dimensions: 4300 OPTIONS 4300 Section
More informationElectronics. Plate 1.1 MPD -1 Computer Display Module Three-Grade, Four-Grade, and Fixed Blender F F
Plate. MPD - Computer Display Module Three-Grade, Four-Grade, and Fixed Blender 3 5 2 2 3 F 5 6 F2 7 8 9 0 7 6 8 9 7 0 5 3 6 2 8 Page 0 PT-80 MPD Series Illustrated Parts Manual /93 Housing, Black T6037-G2S6
More informationNN1 PH1 CC1 DM1 DB1. TABLE V - Options. Mounting Hardware. Instruction Books NN2 PH2 CC2 DM2 DB2. Certificates. PID Control NN C3.
0---0 January 00 Quick Start Guide for UDA Universal Dual Analyzer For detailed instructions see UDA Universal Dual Analyzer Product Manual 0---. Step. Model Number Interpretation Write your analyzer model
More informationAnalyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK
Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL
More information53MC5 53IT5 53ML5 53SL5
Main Processor Boards 686B608U01* 53MC5000A single loop, standard functionality OBSOLETE - order 614C189U01 686B608U02 53MC5000A two loop, standard functionality OBSOLETE - order 614C189U02 686B608U03
More informationSEL-2414 Transformer Monitor
SEL-2414 Transformer Monitor SEL-2414 Base Unit Vertical Chassis Front Panel Large LCD Display 4 Programmable Pushbuttons w/leds 7 Programmable LEDs Operator Control Interface EIA-232 Port Processor and
More information2015 List Prices AquaMaster 120V Lighting for Competitor Fountains
Step 1: Select Light Set Step 2a: 13 & 35W Select Lens Assembly Step 2b: 22W ONLY Select Color Board Assembly Step 3: Select 50ft. Cable Assembly (must Select to keep UL, CE and warranty valid) Step 4:
More informationSignet 9900 Transmitter
Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Panel Mount Field Mount NEW! Modbus Module supports RS485 Serial Modbus Communications Multiple sensor types supported with
More informationSEQUESTR PREfERREd-CUToUT disconnects Mild STEEl SEQUESTR ExTERnal disconnect PaCkagE, TyPE 12 industry STandaRdS application finish SPECifiCaTionS
Spec-224 Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E61997 NEMA/EEMAC Type 12 CSA
More informationSection A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment
April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationSpare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders
PARTS LIST No. PL/RC-001 Date January 2004 Product SM1000 and SM2000 Videographic Recorders Spare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders This parts list contains:
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997
More informationUL 508A Listed; Type 12; File No. E61997 cul Listed per CSA C22.2 No. 94; Type 12; File No. E CSA File No : Type 12
Spec-224 SEQUESTR Preferred-Cutout isconnects SEQUESTR External isconnects Mild Steel SEQUESTR External isconnect Package, Type 12 INUSTRY STANARS UL 58A Listed; Type 12; File No. E61997 cul Listed per
More informationSignet 5700 ph/orp Monitor - ph Instructions
Signet 5700 ph/orp Monitor ph Instructions English *35700.0901* 35700.0901 Rev. K 3/06 English/pH CAUTION! Refer to instruction manual for more details. Remove power to unit before wiring input and output
More information+GF+ SIGNET ph/orp Transmitter Instructions
GF SIGNET 8750 ph/orp Transmitter Instructions ENGLISH 8750.090 A9/99 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More information1/6 STAINLESS STEEL SBC DIG. 316 SENSE AUDIO ENT.PAN. 3ONE6 DOOR ENTRY SYSTEMS OVERVIEW 3451AS
1/6 OVERVIEW Flush-mounted entrance panel (fitted level with the wall) and 3 mm thick stainless steel plate. Certified as IK08. Complete with 128x64 dot LCD graphic display and 15 buttons integrated into
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand
More informationPower Quality and Recording Field Upgrade Available SEL-734, Standard Power Quality, 32 MB Memory SEL-734P, Advanced Power Quality, 128 MB Memory*
SEL-734 Advanced Metering System with ANSI and IEC Class 0.2 Accuracy Standard with: ANSI Type 2 Optical Port, 2 Rear EIA-232 Ports, ACSELERATOR QuickSet SEL-5030 Software, Modbus RTU Communications Protocol,
More informationSM2000 Videographic recorder Spare parts and upgrade kits
ABB MEASUREMENT & ANALYTICS PARTS LIST SM2000 Videographic recorder Spare parts and upgrade kits Measurement made easy Sales Service Introduction This parts list contains: exploded diagrams of the SM2000
More informationBA684DF-P PROFIBUS PA Field mounting Fieldbus Display
BA684DF-P PROFIBUS PA Field mounting Fieldbus Display Issue: 3 Issue: 3 8 th December 2011 2 CONTENTS 1. Description 1.1 Documentation 1.2 Version 3.0 firmware 2. Operation 2.1 Controls 3. System Design
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More information770MAX Multiparameter Analyzer/Transmitter Instruction Manual
Part No. 84372 770MAX Multiparameter Analyzer/Transmitter Instruction Manual Mettler-Toledo Thornton, Inc. 2007 No part of this manual may be reproduced or transmitted in any form or by any means, electronic
More informationSM1000 Videographic recorder Spare parts and upgrade kits
ABB MEASUREMENT & ANALYTICS PARTS LIST SM1000 Videographic recorder Spare parts and upgrade kits Measurement made easy Sales Service Introduction This parts list contains: exploded diagrams of the SM1000
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,
More informationTB84TE Conductivity transmitter 2-Electrode. Superior accuracy in low conductivity and pure water. applications
Data sheet DS/TB84TE EN Rev. C TB84TE Conductivity transmitter 2-Electrode Superior accuracy in low conductivity and pure water applications Smart key menu programming Superior accuracy in low conductivity
More informationAllPro Hazardous/Corrosive Area Fluorescent
CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - 4X UL 844 - Class I Div. 2 - Groups A, B, C, & D UL 4X UL - Outdoor
More informationTongue Switches Trojan 5 & 6
Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key
More informationSee also Accessories. Industrial Corrosion Inhibitors Floor Stand Kit PANELITE Enclosure Lights Overview Bulletin: A28X1, A28X2, A28XM.
Spec-224 H763.422.2211 763.422.26 SEQUESTR Preferred-Cutout s SEQUESTR External s SEQUESTR Preferred-Cutout s SEQUESTR External s SEQUESTR External Package, Type 12 FEATURES INUSTRY STANARS UL 58A Listed;
More informationBXD17 Series. Features. Analytical instrumentation for your measurement applications.
BXD17 Series Analytical instrumentation for your measurement applications. Features Single parameter instrument with temperature measurement capabilities Custom IP66 NEMA 4X (144 x 144mm) enclosure Versatile
More informationDigital Indicator Solutions
Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationABB Automation. Advantage Series ph/orp/pion Analyzer. Type TB84pH. Specification. Simple menu programming (patent pending).
Type TB84pH Advantage Series ph/orp/pion Analyzer Specification Simple menu programming (patent pending). Online continuous sensor diagnostics. Two fully programmable isolated outputs: Zero to 20 ma and
More informationUser Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)
User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure
More informationAnalog Output Module Installation Instructions
Description The Analog Output Module is a component of Novar Controls Spectrum Refrigeration Control System. It produces a varying analog voltage signal to control proportional modulating devices. Control
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationConductivity Transmitters
Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows
More information770MAX Multiparameter Analyzer/Transmitter. Instruction Manual
THORNTON Leading Pure Water Analytics Part No. 84372 770MAX Multiparameter Analyzer/Transmitter Instruction Manual IMPORTANT SAFETY INFORMATION Follow all warnings, cautions, and instructions indicated
More informationThermo Scientific AquaPro Multi-Input Intelligent Process Analyzer
Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer Thermo Scientific AquaPro provides accurate, user-friendly in-line monitoring of process applications from power generation to municipal
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationVCM Systems Vehicle Control Module Systems
VCM Systems Vehicle Control Module Systems Technical Manual VCMS-SC (Standard Configuration) Switch Panel System The Model VCMS-SC Switch Panel System is a standard configuration of the VCMS product family
More informationHydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller
HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended
More informationSignet 5700 ph/orp Monitor - ORP Instructions
Signet 5700 ph/ Monitor Instructions English *5700.0901* 5700.0901 Rev. K /06 English/ Contents 1. Power Connections. Compatible Electrode/Preamp Wiring. 4 0 ma Current Output Connections 4. Relay Connections
More informationINSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro
INSTRUCTION MANUAL Digivac 760 Series Models 100Led 760 100P / 760 100P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro Ranges 0 to 760 Torr 0 to 19.99 Torr 0 to 29.9 inches of mercury The Digivac
More informationResolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F
RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units
More informationSignet ph/orp Transmitter * *
Loop 7 6 5 Signet 8750- ph/orp *-8750.090-* CAUTION! Contents 0.0 ph 5.0C Signet ph/orp. Installation. Panel Installation gasket panel terminals mounting bracket 96 mm (.8 in.) 8050 8 mm (. in.) Optional
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4
763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH
More informationPanel Mount Tachometer, T6
Model T6, Panel Mount Tachometer Features Front programmable Field adjustable parameters Programmable Scaling and Decimal Points 4-20ma Output Signal - Internally Powered by the T6 or Externally Powered
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationPixus Technologies Catalog
The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com S: 96.524.8242 CAN: 59.885.5775 Product Diversity
More informationTable of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3
Chapter Page 1 Introduction 1 1.1 Introduction 1 1.2 Front Panel Description 2 1.3 Rear Panel Description 3 Table of Contents 2 Installation and Operation 4 2.1 Mounting Instructions 4 2.2 Power Connections
More informationPixus Technologies Catalog
The Power of Embedded Ingenuity Pixus Technologies Catalog Kaparel, Ripac, & Vario Brand Products www.pixustechnologies.com sales@pixustechnologies.com US: 96.524.8242 CAN: 59.885.5775 Product Diversity
More informationSolutions to the Most Challenging Environments
Solutions to the Most Challenging Environments Short Catalog Feb, 2017 AM-2300 Multi-Input, Multi-Parameter Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity,
More informationControl Units Ex e in Stainless Steel LCS*.*
Features Assembly Stainless steel enclosures Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex de and Ex tb Up to 4 operators per control unit, base-mounted contact blocks Wide choice of operators,
More informationFEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated
s Flow Meters & Controls ECO FLOMAG i M A G S e r i e s o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects
Spec-01054 Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects Free-Stand Disconnect with Quick-Release Continuous Hinge, Type 4 APPLICATION Simple, heavy-duty with easy door removal
More informationBulletin 800Z Zero-Force Touch Buttons
Bulletin 800Z Zero-Force Touch Buttons IEC and NEMA Style General Purpose Range Heavy Industrial Range Protection Class 4/4X/3 and 4/3 IP66 Internationally Rated Ergonomically Designed Touch Buttons Table
More information*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).
PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council
More informationTable of Contents. 1.1 General System Features Instrument Specifications Performance Specifications 12
Table of Contents Part 1 Part 2 Part 3 Part 4 Part 5 Introduction 1.1 General 5 1.2 System Features 7 1.3 Instrument Specifications 9 1.4 Performance Specifications 12 Mounting 2.1 General Mounting 13
More informationModel Selection Guide 250mm Strip Chart Recorder with Price Data
Page: DPR-29 DPR250 Recorder Model Selection Guide 250mm Strip Chart Recorder with Price Data Model Selection Guide 43-DR-16-19 Issue 10 Instructions Select the desired Key Number. The arrow to the right
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter
ABB MEASUREMENT & ANALYTICS DATA SHEET TB84PH ph /ORP / pion transmitter 2 TB 8 4PH P H /ORP / P I ON TR AN S MIT TE R DS/ TB8 4PH-E N RE V. D Measurement made easy Hazardous area rated transmitter with
More informationLift Truck Parts Professionals
SB Connector 50 Amp Series connectors Housing w/springs Anderson Brad Anderson & contacts Wire AWG Part # Harrison # Part # Original # Gray 50 amp #6 69 900 000 7-70-P 000 7-70 #0/# 69G 90 000 7-7-P 000
More informationSpecifications. Description TABLE OF CONTENTS. Page. Description 2. Specifications 2 3. Additional Options 3. How to Order 4 5
TABLE OF CTENTS Page Description Specifications Additional Options How to Order Circuit Descriptions Dimensions 0 Icons into the body of the switch; mounting hardware or special tools are not necessary.
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationType NT and Type ZWM Terminal Blocks
Type NT and Type ZWM Terminal Blocks Unit-pole construction Sliding link to permit testing without disturbing wiring High barriers that prevent shorting between poles Class 1E qualified per IEEE RECOGNIZED
More informationeztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary.
Datasheet -- Representative photograph, actual product appearance may vary. Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell
More informationFEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated
s Flow Meters & Controls ECO FLOMAG imag Series o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved
More informationPS-4100 POWER SUPPLY MANUAL
PS-4100 POWER SUPPLY MANUAL Manual Part Number 180-0573 December 7, 2006 TABLE OF CONTENTS TITLE PAGE Table of Contents... 2 List Of Figures... 3 1. Introduction... 4 1.0. General... 4 1.1. Features...
More informationStandard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
Spec-00251 Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 SPECIFICATIONS 11 gauge steel (.121 inch) Seams continuously welded
More informationCDN502 HIGH DENSITY I/O ADAPTER USER GUIDE
CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER
More informationFree-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12
Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File
More informationIndustrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4
Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories
More informationEffective May 2018 Supersedes October 2017
Technical Data TD280028EN Supersedes October 2017 COOPER POWER SERIES NOVA NX-T Recloser, Form 6 NX-T, and Form 6LS NX-TRecloser Control and Accessories Ordering Guide Eaton provides reliable, economical
More informationAPS2200CW SCALE SERIES DIMENSIONS
2200CW Section page 4 APS2200CW SCALE SERIES DIMENSIONS Model APS2200CW Recommended Column/Base Combinations 14" Column standard for these base sizes: 20" Column standard for these base sizes: 30" Column
More informationContents. 1. Installation
ENGLISH 8750.090 C/0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation. Specifications. Electrical
More informationEcoFlex LED Neon Manual
Manual Part number: LN-ECO-XXXX-10m from Environmental Lights is one of the most flexible and cost-effective members of our line of LED Neon products. It allows you to achieve the creative potential of
More informationimag-series Flanged Magmeter
s Flow Meters & Controls imag-series o M o vi n g P a r t N FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved (3 only) IP68 rated 9001:2008 ISO
More informationBrasch Washdown Unit Heaters
Brasch Washdown Unit Heaters Standard Features: Up to 48 KW Up to 400 Volts Disconnect switch with enclosure interlock Heavy-duty 304 stainless steel shroud Nema 4x non-metallic control panel 24-volt
More informationT80 Universal Transmitter S80 Intelligent Sensors
T80 Universal Transmitter S80 Intelligent Sensors Presented by: January 2012 ELECTRO-CHEMICAL DEVICES T80 Universal Transmitter One Transmitter for Multiple Measurements ph ORP Dissolved Oxygen All Specific
More informationHigh Density Connectors Multipin and MS Multipin MS High Current and High Voltage
Multipin is the description for electrical feedthroughs which have two or more conductor paths, and include connectors for one or both sides. This series is typically used for transmission of low power
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationOPERATION MANUAL MODEL TT-LP
TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors
More information1. Carefully unpack the um260 s shipping carton and check the contents for damage.
um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing
More informationControl and automatic dosing
Control and automatic dosing For public and residential pools Control Basic and Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control
More informationThetford Corp. Refrigerator Replacement Parts List
Thetford Corp. Refrigerator Replacement Parts List NE SERIES NE SERIES NE SERIES NE.F NE.F NE.F Part No. 677 NORCOLD /8/08 Cabinet Area - Front View - NE 7 6 6 0 9 8 ART 0 NO. PART # DESCRIPTION NE.F 670
More information200CRS Single-Channel Conductivity/Resistivity Measurement System THORNTON. Leading Pure Water Analytics
THORNTON Leading Pure Water Analytics - NIST Traceable Calibration - Two Analog Outputs Standard - Three-Wire Temperature Measurement - Wide Range of Sensor and Cable Selections 200CRS Single-Channel Conductivity/Resistivity
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationAnalytical Instruments Two-Wire ph, ORP, plon Transmitters
Data Sheet Analytical Instruments Two-Wire ph, ORP, plon Transmitters Model TB82PH Series Designed With the Real World in Mind Easy to use menus guide the operator through set-up, calibration and maintenance
More informationEMC Shielding Clear plated components (exterior painted) and a conductive fabric-over-foam gasket provide an HF2 level of shielding.
Spec-00418 E763.422.2211 763.422.2600 PROLINE External Components PROLINE Doors, Covers and Sides PROLINE External Components PROLINE Doors, Covers and Sides Door Gasketing, Shielding and Door Bars Overview
More informationMAG. ECO FLO imag Series NSF FEATURES
Flow Meters & Controls MAG ECO FLO imag Series M o vi n g P s N o rt w U NSF o n Easy setup Minimal straight pipe Mounted or remote rate & total 4-2mA output available Tamper-evident seal NSF-61 approved
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationInverter Selection Guide
Inverter Selection Guide KB Electronics, Inc. Chassis / IP20 models include Motor Filters to eliminate winding and bearing failures. Hybrid Drives are digital drives with an analog interface. Digital models
More information