1 Operation Manual for Mag612 Three-Axis Magnetic Field Probe

2 Table of Contents 1. About this Manual Symbols Glossary 3 2. Safe Use 3 3. Introduction 3 4. Overview of the Mag Magnetic Field Sensor Circuit Design 4 6. Probe Location and Mounting Recommendations 4 7. Connections 5 8. Mag612U Electronics Board Connecting the Probe and Electronics Board 6 9. Mag612-RTPDE and -RTUDE Integration Considerations Cable Testing Cable Recommendations Connecting Power Electromagnetic Compatibility Troubleshooting and Care and Maintenance Troubleshooting Care and Maintenance Product Handling Storage & Transport Environmental Precautions End of Life Disposal 9 Page 2 of 10

3 1. About this Manual This manual provides the information necessary to help customers connect, and operate, the Bartington Instruments Mag612 probe and electronics board. It should be read in conjunction with the product brochure DS3434 and the outline drawings available from the product page Symbols Glossary The following symbols used within this manual call your attention to specific types of information: WARNING: Indicates a situation in which serious bodily injury or death could result if the warning is ignored. Caution: Indicates a situation in which bodily injury or damage to your instrument, or both, could result if the caution is ignored. Identifies items that must be disposed of safely to prevent unnecessary damage to the environment. Note: A paragraph in this format provides useful supporting information on how to make better use of your purchase. 2. Safe Use WARNING: These products are not qualified for use in explosive atmospheres or life support systems. Consult Bartington Instruments for advice. Caution: To prevent irreparable damage, electrostatic discharge (ESD) protection and precautions must be used when handling the unpackaged sensor electronics board. 3. Introduction The Mag612 is a three-axis fluxgate probe with a separate electronics board. The probe is for use together with electronics to provide measurements of static and alternating magnetic fields in three orthogonal axes. Page 3 of 10

4 4. Overview of the Mag612 The Mag612U is a two-part three-axis fluxgate sensor with a superior orthogonality. It consists of a compact, lightweight and environmentally sealed fluxgate probe and unpackaged electronics, connected by a cable up to 3 metres in length. Figure 1. Mag612 probe The probe can be mounted into the customer equipment with the electronics located remotely. The Mag612 probe is supplied with a connector allowing easy connection to either its decicated electronics or the RTPDE. In the case of supply with the RTUDE, the sensor will be hard wired to the RTUDE. 5. Magnetic Field Sensor Circuit Design Compatible unpackaged room temperature electronics are included with the Mag612U sensors. See Mag612U Electronics Board. Magnetic field sensor circuit schematics and design notes are available, at additional cost, from Bartington Instruments. Contact the Bartington Instruments sales team for more information on sales@bartington.com. 6. Probe Location and Mounting Recommendations The probe should be located away from large magnetic fields or materials that may over-range the sensor or interfere with the field being measured. The method of mounting will depend on the application and the enclosure. Page 4 of 10

5 Each probe has four countersunk fixing holes, for M2.5 screw attachment to a stable base of fixture. For details of the mounting arrangements for the probe refer to drawing DR3622, available from Bartington Instruments. Note: The use of magnetic materials in the mounting arrangement must be avoided. All mounting components should be checked before installation, by introducing the component within the immediate vicinity of the sensing elements of a working magnetic field sensor, and observing any variation in the background field. The analogue output is positive for conventional flux direction, South to North, in the direction of the arrow shown on DR3622 for each axis; i.e. the maximum positive output will be obtained from any axis when the arrow points towards magnetic north along the total field vector. 7. Connections Connection details for the Mag612 probe are provided in DR3622, available from Bartington Instruments. 8. Mag612U Electronics Board The separate Mag612 electronics board (figure 2) is unpackaged and is used to operate Mag612 three-axis probes. Figure 2. Mag612 electronics board Page 5 of 10

6 8.1. Connecting the Probe and Electronics Board Prior to the installation of the system, the electronics board must be connected to a Mag612 probe to provide sensor functionality. The electronics should then be connected to a suitable power supply and acquisition unit. The Mag612 probe can either be soldered onto the electronics, or supplied with a detachable connector. Diagrams showing the connectors and solder points are available from Bartington Instruments. 9. Mag612-RTPDE and -RTUDE In the event the customer whish to integrate the Mag612 probe to their own design electronics, schematics can be purchased from Bartington Defence & Space. For evaluation purpose, packaged and unpackaged drive electronics corresponding, to the schematics can be supplied as an optional extra. Outline drawing for the RTPDE and RTUDE are available from the Mag612 Page. Connection of the Mag612 probe to the RTPDE is done via a Hirose connector, where the probe will connect to the body of the RTPDE. The other hirose connector on the RTPDE is suitable for connection to Bartington Defence & Space power supply and data acquisition units. Connection of the Mag612 probe is hard wired to the RTUDE. The RTUDE will be also supplied with a Hirose connector mounted on a tail for connection to Bartington Defence & Space power supply and data acquisition units. 10. Integration Considerations The electronics board design has a flat amplitude response and a small, predictable phase lag. In order to offer maximum flexibility and not degrade the performance, it has no internal filters. The analogue outputs may require external filters to optimise their performance, depending on the application. 11. Cable Testing The cabling from the power supply to the Mag612 electronics board must be fully tested to ensure the correct functionality. Site the sensor and connect the power supply and cabling. Ensure the connections are installed in the correct orientations. Page 6 of 10

7 Switch on the power supply and wait until the sensor has stabilised. Refer to the technical specification in the brochure for warm-up times. Confirm no magnetic objects are moving in the vicinity. To check the output: Connect a voltmeter to the axis sensor outputs (across signal and common). Whilst monitoring the voltmeter readings, align the probe axis with the terrestrial magnetic field. Confirm that the measured readings approach the local geomagnetic field value. 12. Cable Recommendations The Mag612 electronics board provides unbalanced output lines for analogue signal transmission. Note: Customers manufacturing their own cables must ensure the cables are shielded to prevent them picking up electromagnetic interference. The connecting cable to the electronics board output connector should be an eight-core screened cable. Note: Cables are particularly prone to wear and damage if twisted, flexed beyond their design limits, or subjected to excessive or repeated movement. All cables should be mounted securely in place. 13. Connecting Power Caution: Check that the polarity of the supply is correct before powering the sensor. Caution: Connect the Mag612 electronics board before the supply is energised, as this prevents high surge currents which could cause damage. Note: Apply the positive and negative supplies simultaneously, and avoid leaving the electronics board connected to one polarity only. 14. Electromagnetic Compatibility Note: The Mag612 probe and electronics board are not shielded for immunity from, or emission of, electromagnetic fields. Page 7 of 10

8 Note: The Mag612 is intended for integration into other systems. Ensure these meet the appropriate level of shielding. 15. Troubleshooting and Care and Maintenance Troubleshooting Your sensor is unlikely to suffer any defects in normal use: no internal components are serviceable. The most likely causes of failure, and their solutions, are detailed in the following table. In the event of any apparent malfunction beyond those described in the table below, please or telephone the Bartington Instruments service team on +44 (0) Cause Power supply Cables Solution Check the power supply as detailed in Connecting the Probe and Electronics Board. Check the cables as detailed in Cable Testing. Power input If no fault can be found in the power supply or cables, ensure the cable length is not too long, causing excessive voltage drop between the power supply and electronics board. Refer to the parameters defined in the brochure technical specification. Damaged sensor If any physical damage is apparent to the module and / or the casing then the sensor may need to be replaced. For information about disposal of a damaged unit, refer to End of Life Disposal Care and Maintenance Surface dirt contamination on the Mag612 probe should be removed using a mild detergent solution only. 16. Product Handling ESD protection should be used when handling the Mag612 electronics board, to prevent irreparable damage. Page 8 of 10

9 17. Storage & Transport The Mag612 electronics board should be treated subject to ESD precautions. Note: Store only within the temperature range specified in the product brochure. Note: Do not expose to strong magnetic fields while being stored. 18. Environmental Precautions Refer to the brochure for maximum environmental electrical and mechanical ratings. Caution: Exceeding the maximum environmental ratings may cause irreparable damage to the Mag612 probe and electronics board. 19. End of Life Disposal This product (electrical and electronic equipment) should not be placed in municipal waste. Check local regulations for disposal of electronic products. Page 9 of 10

10 T: +44 (0) F: +44 (0) E: Bartington Instruments Limited 5 Thorney Leys Business Park, Witney, Oxford, OX28 4GE, England. The copyright of this document is the property of Bartington Instruments Ltd. Bartington is a registered trade mark of Bartington Instruments Limited in the following countries: United Kingdom, Australia, Brazil, Canada, China, European Union, India, Japan, Norway and the United States of America.

Mag High Temperature Three-Axis Magnetic Field Probes

Mag High Temperature Three-Axis Magnetic Field Probes INNOVATION IN MAGNETICS Operation Manual for Mag610-611 High Temperature Three-Axis Magnetic Field Probes www.bartington.com Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use

More information

Operation Manual for. Mag628/629 and Mag669 Three-Axis Aerospace Magnetometers.

Operation Manual for. Mag628/629 and Mag669 Three-Axis Aerospace Magnetometers. Operation Manual for Mag628/629 and Mag669 Three-Axis Aerospace Magnetometers www.bartingtondefenceandspace.com www.bartingtondefenceandspace.com Table of Contents 1. How to Use this Manual 3 1.1. Symbols

More information

Innovation in Magnetic Field Measuring Instruments. Mag648 & Mag649. Low Power Three-Axis Magnetic Field Sensors.

Innovation in Magnetic Field Measuring Instruments. Mag648 & Mag649. Low Power Three-Axis Magnetic Field Sensors. Innovation in Magnetic Field Measuring Instruments Mag648 & Low Power Three-Axis Magnetic Field Sensors www.bartington.com Mag648 & Low Power Three-Axis Magnetic Field Sensors Bartington Mag648 and Low

More information

INNOVATION IN MAGNETICS DS0013/27. Mag-03. Three-Axis Magnetic Field Sensors.

INNOVATION IN MAGNETICS DS0013/27. Mag-03. Three-Axis Magnetic Field Sensors. INNOVATION IN MAGNETICS DS0013/27 Mag-03 Three-Axis Magnetic Field Sensors www.bartington.com Mag-03 Three-Axis Magnetic Field Sensors Mag-03 Three-Axis Magnetic Field Sensors These compact, high performance

More information

Spacemag & Spacemag-Lite

Spacemag & Spacemag-Lite Spacemag & Spacemag-Lite Three-Axis Magnetometers World Leaders Magnetic Measuring Instruments Spacemag & Spacemag-Lite Three Axis Magnetometer Bartington Spacemag & Spacemag-Lite Three-Axis Magnetometers

More information

Operation Manual for. Mag-01 & Mag-01H Single Axis Fluxgate Magnetometers with Mag Probes B-G

Operation Manual for. Mag-01 & Mag-01H Single Axis Fluxgate Magnetometers with Mag Probes B-G Operation Manual for Mag-01 & Mag-01H Single Axis Fluxgate Magnetometers with Mag Probes B-G Table of Contents 1. About this Manual 4 1.1. Symbols Glossary 4 2. Safe Use 4 3. Introduction 4 4. The Magnetometers

More information

Data Acquisition & Signal Conditioning Units

Data Acquisition & Signal Conditioning Units INNOVATION IN MAGNETICS DS2519/16 Data Acquisition & Signal Conditioning Units www.bartington.com Data Acquisition & Signal Conditioning Units Data Acquisition and Signal Conditioning Units Bartington

More information

Mag-03. Three-Axis Magnetic Field Sensors.

Mag-03. Three-Axis Magnetic Field Sensors. Mag-03 Three-Axis Magnetic Field Sensors World www.bartingtondefenceandspace.com Leaders Magnetic Measuring Instruments www.bartingtondefenceandspace.com Mag-03 Three Axis Magnetic Field Sensor Bartington

More information

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System.

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System. INNOVATION IN MAGNETICS DS-2201/8 DAS1 Data Acquisition System www.bartington.com DAS1 Data Acquisition System DAS1 Data Acquisition System The DAS1 is a multi-sensor data acquisition system designed to

More information

INNOVATION IN MAGNETICS DS0070/12. Mag-01H D/I. Declinometer/Inclinometer System.

INNOVATION IN MAGNETICS DS0070/12. Mag-01H D/I. Declinometer/Inclinometer System. INNOVATION IN MAGNETICS DS0070/12 Mag-01H D/I Declinometer/Inclinometer System www.bartington.com Mag-01H D/I Declinometer/Inclinometer System Mag-01H D/I Fluxgate Declinometer/Inclinometer System The

More information

Innovation in Magnetic Field Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors.

Innovation in Magnetic Field Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors. Innovation in Magnetic Field Measuring Instruments Mag-03 Three-Axis Magnetic Field Sensors www.bartington.com Mag-03 Three-Axis Magnetic Field Sensors Bartington Mag-03 Three-Axis Magnetic Field Sensors

More information

Innovation in Magnetic Field Measuring Instruments. Grad601. Magnetic Gradiometer System

Innovation in Magnetic Field Measuring Instruments. Grad601. Magnetic Gradiometer System Innovation in Magnetic Field Measuring Instruments Grad601 Magnetic Gradiometer System Grad601 Magnetic Gradiometer System Bartington Grad601 Magnetic Gradiometer System The Grad601 is a fluxgate gradiometer,

More information

Operation Manual for. Geolabsoft for Windows (PC version)

Operation Manual for. Geolabsoft for Windows (PC version) Operation Manual for Geolabsoft for Windows (PC version) Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 1.2. Running Windows-based Applications 3 2. Introduction 3 3. Software Installation

More information

Innovation in Magnetic Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors

Innovation in Magnetic Measuring Instruments. Mag-03. Three-Axis Magnetic Field Sensors Innovation in Magnetic Measuring Instruments Mag-03 Three-Axis Magnetic Field Sensors Mag-03 Three Axis Magnetic Field Sensors Mag-03 Three-Axis Magnetic Field Sensors These compact, high performance fluxgate

More information

Mag-03. Three-axis Magnetic Field Sensors. For innovation in magnetic measuring instruments

Mag-03. Three-axis Magnetic Field Sensors. For innovation in magnetic measuring instruments Mag-03 Three-axis Magnetic Field Sensors For innovation in magnetic measuring instruments Mag-03 Three-Axis Magnetic Field Sensors These compact, high performance sensors with integral electronics provide

More information

Mag-01H. Fluxgate Declinometer/Inclinometer. Mag-01H D/I. World leaders in high precision magnetic field measurements

Mag-01H. Fluxgate Declinometer/Inclinometer. Mag-01H D/I. World leaders in high precision magnetic field measurements Mag-01H D/I World leaders in high precision magnetic field measurements Mag-01H Fluxgate Declinometer/Inclinometer Distributed By: GMW Associates 955 Industrial Road, San Carlos, CA, 94070 USA PHONE: +1

More information

HCS1 Three-Axis Helmholtz Coil System

HCS1 Three-Axis Helmholtz Coil System HCS1 Three-Axis Helmholtz Coil System Innovation in Magnetic Measuring Instruments HCS1 Three-Axis Helmholtz Coil System HCS1 Three-Axis Helmholtz Coil System The system consists of three pairs of coils

More information

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys For innovation in magnetic measuring instruments Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration

More information

Mini Probe. user manual. DM Models

Mini Probe. user manual. DM Models Mini Probe user manual DM Models 1.0: Index Section Title Page 1.0 Index...............................2 2.0 Safety Summary......................3 3.0 Introduction..........................4 4.0 Components

More information

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units Innovation in Magnetic Measuring Instruments Data Acquisition & Conditioning Units Data Acquisition and Conditioning Units Data Acquisition and Conditioning Units Bartington s wide range of data acquisition

More information

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

User s Manual Model PBL100 Logic Probe IM E. 4th Edition User s Manual Model 701988 PBL100 Logic Probe 4th Edition Foreword Thank you for purchasing the PBL100 100 MHz Logic Probe (Model 701988). This user s manual describes the functions, operating procedures,

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

Before installing or performing routine maintenance upon this equipment, follow the general precautions listed in this section.

Before installing or performing routine maintenance upon this equipment, follow the general precautions listed in this section. Safety Before installing or performing routine maintenance upon this equipment, follow the general precautions listed in this section. WARNING: RISK OF ELECTRIC SHOCK - May result in serious injury or

More information

GMH Operating Manual for Digital Quick-Response Thermometer

GMH Operating Manual for Digital Quick-Response Thermometer H58.0.01.6C-02 Operating Manual for Digital Quick-Response Thermometer GMH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-IR Series D) Use this document as a guide when installing the 1771-IR/D input module. The RTD input module is sensitive to electrostatic discharge. ATTENTION:

More information

D-SEED effects pedal. user manual

D-SEED effects pedal. user manual D-SEED effects pedal user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 11.04.2014, ID: 318119 Table

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Installation Instructions

Installation Instructions Installation Instructions Cat. No. 1771-IQ16 Series C This document provides information on: The dc isolated input module is shipped in static-shielded packaging to guard against electrostatic discharge

More information

You need the following to set up and use your terminal block:

You need the following to set up and use your terminal block: INSTALLATION GUIDE NI TB-2706 PXI/PXIe Terminal Block for M Series and NI 6143 Devices Contents Introduction This installation guide describes how to install and connect signals to the NI TB-2706 terminal

More information

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

B63/ NS MS. EtherNet/IP LINK

B63/ NS MS. EtherNet/IP LINK 3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK 3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Digital Quick-Response Thermometer

Digital Quick-Response Thermometer H56.0.01.6C-06 Digital Quick-Response Thermometer Operating Manual GTH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

CEM M-RS485 INSTRUCTION MANUAL (M014B A) Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could

More information

Flexoled FTP3HP RGB LED DMX Driver

Flexoled FTP3HP RGB LED DMX Driver Flexoled FTP3HP RGB LED DMX Driver User Manual + 12-24V DMX INPUT DMX OUTPUT DC IN (12A MAX) DMX ADDRESS & DIMMER SETTINGS SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT-IN MODE LOAD 4A PER CHANNEL (12A MAX)

More information

HD40H(X) Performance Series Camera. User Guide

HD40H(X) Performance Series Camera. User Guide HD31H(X) HD30H(X) HD40H(X) Performance Series Camera User Guide Document 1 2 HD40H(X)/HD30H(X)/HD31H(X) Camera User Guide Thank you for purchasing our product. If there are any questions, or requests,

More information

SDG1400 User s Guide

SDG1400 User s Guide SDG1400 User s Guide Model SDG1400 Rate Sensor Systron Donner Inertial Sales and Customer Service Phone: +1 925.979. 4500 Fax: +1 925.349.1366 E-Mail: sales@systron.com www.systron.com SDG1400 User s Guide

More information

User s Manual Model PBL250 Logic Probe IM E. 3rd Edition

User s Manual Model PBL250 Logic Probe IM E. 3rd Edition User s Manual Model 701989 PBL250 Logic Probe 3rd Edition Foreword Thank you for purchasing the PBL250 250 MHz Logic Probe (Model 701989). This user s manual describes the functions, operating procedures,

More information

FP-PS-4. Features. Installation

FP-PS-4. Features. Installation OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply

More information

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776 JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT JR3, Inc. 22 Harter Ave. Woodland, CA 95776 5962C 15 December, 2003 TABLE OF CONTENTS CHAPTER 1 OVERVIEW General...1-1 Sensor...1-1 Electronic System...1-1

More information

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number Installation Note Removable Hard Disk Drive Upgrade Kit For All PNA Series RF Network Analyzers Network Analyzer Model Number E8356A, E8357A, E8358A E8801A, E8802A, E8803A N3381A, N3382A, N3383A Upgrade

More information

TA18 active subwoofer. user manual

TA18 active subwoofer. user manual TA18 active subwoofer user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 30.11.2011 Table of contents

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide USB 2.0 RG2324/2344 4-Port USB 2.0 Fiber Optic Extender System User Guide Thank you for purchasing the USB 2.0 RG2324 or RG2344. This document applies to the following part numbers: Please read this guide

More information

UV Power Flood. User Manual. Order code: EQLED029

UV Power Flood. User Manual. Order code: EQLED029 UV Power Flood User Manual Order code: EQLED029 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

PF LED Profile. User Manual

PF LED Profile. User Manual PF LED Profile User Manual Order codes: ELUM094-100W 3200K WW Version ELUM095-100W 6000K CW Version ELUM096-150W 3200K WW Version ELUM097-150W 6000K CW Version Safety advice WARNING FOR YOUR OWN SAFETY,

More information

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual Instruction Manual PG Interface Card for FRENIC-VG OPC-VG1-PG / PGo Thank you for purchasing our PG interface card designed for the high-performance, vector control FRENIC-VG series of inverters. - Improper

More information

For Raspberry Pi - Getting started

For Raspberry Pi - Getting started For Raspberry Pi - Getting started Extend your PiFace Relay+ with the PiFace Motor EXTRA board, allowing you to control DC motors. Product highlights Typical applications: Robotics Motor control Home automation

More information

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

ZF LED Zoom Fresnel. User Manual

ZF LED Zoom Fresnel. User Manual ZF LED Zoom Fresnel User Manual Order codes: ELUM090-100W 3200K WW Version ELUM091-100W 6000K CW Version ELUM092-150W 3200K WW Version ELUM093-150W 6000K CW Version Safety advice WARNING FOR YOUR OWN SAFETY,

More information

CS2 DMX Distribution Splitter

CS2 DMX Distribution Splitter CS2 DMX Distribution Splitter User Manual Order code: BOTE72 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up,

More information

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS Serial Communications Accessories SITRANS RD200/300 Operating Instructions 05/2013 SITRANS Siemens Auto SIT SITRANS RD300RANS RD300 Safety Guidelines: Warning notices must be observed to ensure personal

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module using the indicators for troubleshooting

More information

FTP1 Single Channel LED DMX Driver

FTP1 Single Channel LED DMX Driver FTP1 Single Channel LED DMX Driver User Manual FTP1 LOAD ANALOG Order code: FLEX29 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before

More information

xbrick Full-Colour 16 3W LED floodlight user manual

xbrick Full-Colour 16 3W LED floodlight user manual xbrick Full-Colour 16 3W LED floodlight user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (9546) 9223-0 email: info@thomann.de Internet: www.thomann.de 15.11.2011

More information

AWP-24 Wave Height Gauge User's Guide

AWP-24 Wave Height Gauge User's Guide AWP-24 Wave Height Gauge User's Guide Issue: 2.3 5-October-2012 Prepared by Akamina Technologies Inc. Akamina Technologies Inc. 91 Norice St.,Ottawa,Ontario K2G 29, CANADA TEL: +1 613 720 7555 FA: +1 613

More information

Crossfire. User Manual. Order code: EQLED061

Crossfire. User Manual. Order code: EQLED061 Crossfire User Manual Order code: EQLED061 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure

More information

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual Document number 057-135 Author : Paul Gibbons DSE103 MKII Operator Manual Issue 1 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory Intel NUC Kit NUC7i7BNHX1 with Intel Optane Memory User Guide 1 Before You Begin CAUTIONS The procedures

More information

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices INSTALLATION GUIDE NI CB-7F-LP Connector Block for 7-Pin D-Sub Devices Introduction This installation guide describes how to install and connect signals to the NI CB-7F-LP connector block for use with

More information

Microbar COB System. User Manual. Order code: EQLED137

Microbar COB System. User Manual. Order code: EQLED137 Microbar COB System User Manual Order code: EQLED137 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Installation Instructions

Installation Instructions Installation Instructions (1771-ODD Series B) Use this document as a guide when installing the catalog number 1771-ODD series B output module. The ac isolated output module is shipped in static-shielded

More information

AWP-24-3 Wave Height Gauge User's Guide

AWP-24-3 Wave Height Gauge User's Guide AWP-24-3 Wave Height Gauge User's Guide Issue: 1.5 Status: Released 18-Dec-2014 Prepared by Akamina Technologies Inc. Akamina Technologies Inc. 91 Norice St.,Ottawa,Ontario K2G 2X9, CANADA TEL: +1 613

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Product Identification Product name Package Noise* Range in µt Mag-03 MC= Cylindrical B = Basic ±70 MCES = Cylindrical, environmentally sealed to IP64

Product Identification Product name Package Noise* Range in µt Mag-03 MC= Cylindrical B = Basic ±70 MCES = Cylindrical, environmentally sealed to IP64 Mag-03 Three Axis Magnetic Field Sensors Mag-03 Three-Axis Magnetic Field Sensors These compact, high performance fluxgate sensors with integral electronics provide precision measurements of static and

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies

More information

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ User Guide 1 Before You Begin CAUTION The procedures in this guide assume familiarity with

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

PAR56 10MM UV LED PAR. user manual

PAR56 10MM UV LED PAR. user manual PAR56 10MM UV LED PAR user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 03.12.2012 Table of contents

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116 INSPECTION CAMERA MODEL NO: CIC2410 PART NO: 6470385 OPERATION & SAFETY INSTRUCTIONS GC0116 INTRODUCTION Thank you for purchasing this CLARKE Inspection Camera. Before attempting to use this product, please

More information

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-7DU2i 2 USBG-7DU2i Product Manual Revision History Revision

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Blitzer Strobe. User Manual. Order code: EQLED366

Blitzer Strobe. User Manual. Order code: EQLED366 Blitzer Strobe User Manual Order code: EQLED366 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

TBX-96 TERMINAL BLOCK

TBX-96 TERMINAL BLOCK INSTALLATION GUIDE TBX-96 TERMINAL BLOCK This guide describes how to install and use the TBX-96 terminal block with the SCXI-1100, SCXI-1102B/C, SCXI-1104/C, and SCXI-1581 modules. The TBX-96 is a shielded,

More information

For Raspberry Pi - Getting started

For Raspberry Pi - Getting started For Raspberry Pi - Getting started Extend your PiFace Relay+ with the PiFace Relay EXTRA board, allowing you to control twice as many circuits. Product highlights Typical applications: Robotics Motor control

More information

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10100902 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated

More information

EH-RIO IP67 Profibus-DP I/O modules

EH-RIO IP67 Profibus-DP I/O modules Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP

More information

INNOVATUM REFERENCE MANUALS. Section 4-1. Smartrak Description & Installation

INNOVATUM REFERENCE MANUALS. Section 4-1. Smartrak Description & Installation INNOVATUM REFERENCE MANUALS Section 4-1 Smartrak Description & Installation The electronic version of this document is the controlled copy. All printed versions are thus uncontrolled and may not be current.

More information

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776 JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT JR3, Inc. 22 Harter Ave. Woodland, CA 95776 5963B 13 October, 2003 TABLE OF CONTENTS CHAPTER 1 OVERVIEW General...1-1 Sensor...1-1 Electronic System...1-1

More information

Achat 110 MA active full-range speaker. user manual

Achat 110 MA active full-range speaker. user manual Achat 110 MA active full-range speaker user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 14.02.2012

More information

TA12 full-rangespeaker. user manual

TA12 full-rangespeaker. user manual TA12 full-rangespeaker user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 30.11.2011 Table of contents

More information

DC 100 A Current Probe

DC 100 A Current Probe 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Model: CP62 Visit us at www.testequipmentdepot.com DC 100 A Current Probe USER MANUAL 1 Safety Summary The following safety

More information

Manual Version: V1.01. Network Bullet Cameras Quick Guide

Manual Version: V1.01. Network Bullet Cameras Quick Guide Manual Version: V1.01 Network Bullet Cameras Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC6CAYS User Guide Intel NUC Kit NUC6CAYS User Guide Regulatory Model NUC6CAY 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

HP4 headphone amplifier. user manual

HP4 headphone amplifier. user manual HP4 headphone amplifier user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 03.11.2015,

More information

Achat 112 MA Achat 112 MA WH full-range speaker. user manual

Achat 112 MA Achat 112 MA WH full-range speaker. user manual Achat 112 MA Achat 112 MA WH full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet:

More information

Operating Manual. Guardian Series Safety Compliant Melt Pressure Transducer

Operating Manual. Guardian Series Safety Compliant Melt Pressure Transducer Guardian Series Safety Compliant Melt Pressure Transducer PL c rated mv/v and ma HART pressure transducer with integrated safety relay output Operating Manual -1- Overview This manual is intended to cover

More information

DPX-620III 6-Ch. dimmer pack. user manual

DPX-620III 6-Ch. dimmer pack. user manual DPX-620III 6-Ch. dimmer pack user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 28.08.2017,

More information

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD. SUN2000-(2KTL-5KTL)-L0 Quick Guide Issue: 01 Part Number: 31509986 Date: 2018-09-05 HUAWEI TECHNOLOGIES CO., LTD. 0 NOTICE 1. The information in this document is subject to change without notice. Every

More information

DMX Splitter 4 MKIII 19" DMX splitter. user manual

DMX Splitter 4 MKIII 19 DMX splitter. user manual DMX Splitter 4 MKIII 19" DMX splitter user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

FIBER OPTIC TRANSMITTING MODULE TOTX147(F,T)

FIBER OPTIC TRANSMITTING MODULE TOTX147(F,T) FIBER OPTIC TRANSMITTING MODULE TOTX147(F,T) FIBER OPTIC TRANSMITTING MODULE FOR DIGITAL AUDIO EQUIPMENT Unit: mm Conforms to JEITA Standard CP 1212 (Digital Audio Optical Interface for Consumer Equipment).

More information