1 IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width, the PDUs can be easily integrated into your IT rack. Their multi-functional mounting brackets allow the units to be easily mounted in various ways (e.g. inwardly recessed). Our high quality standards ensure that the contact is reliable. Torsionally rigid 1 U aluminium profile, 1" format Up to x socket inserts in the 1" format Flexible positioning and universal attachment options The modular platform allows individual solutions to be Anodised profiles in or End caps riveted or rewirable Earthing contact and IEC020 sockets Various country versions Illuminated 2-pole switch Locking of IEC020 plugs -way and -way variants (no 1" format) Type III. KA overvoltage protection Mains and frequency filters Protection with micro fuse 0 ma residual current device Micro circuit breaker Master + Slave function Sockets set at project-planned Versions available: Pictograms and their meaning can be found on page 2.
2 1" IT PDU Basic (20 V / 0 Hz) Profile colour C C C20.1 Terminal.0 Terminal C1 C1.01 / with locking clips 0. Thermal fuse A RCD 0 ma B1A miniature circuit breaker Cable type: m H0VV-F G 1.0 mm² Nominal voltage: 20 V Current per phase: 1 A Mains and frequency filters With mains and frequency filters.0. With fuse C1.. C C C For more 1" power strips >1 U, see from page 20. Pictograms and their meaning can be found on page 2.
3 IT PDU Basic (20 V / 0 Hz) / Dimensions Cable type: m H0VV-F G 1.0 mm² : Current per phase: 1 A.1 x x mm ''.1 20 x x mm x x mm.20 0 x x mm " IT PDU Basic Master + Slave (20 V / 0 Hz) Phase(s) Rated voltage (V) Current per phase (A) / Cable type: m H0VV-F G 1.0 mm² Automatically isolates the master unit and all slave units from the mains supply once the master unit is shut down/switched off Automatically switches on master device and all slave devices once master device has been switched on Integral LED indicates switching state " fuse box (2 A / 00 V / 0 Hz) Phase(s) Rated voltage (V) Current per phase (A) Miniature circuit breaker x 2 A 00 2 x C1 x 1 A Cable type: m H0VV-F G.0 mm² Space-saving option of splitting a 2 A/00 V infeed between two 1 A/00 V infeeds x 1 A miniature circuit breakers with characteristic C Pictograms and their meaning can be found on page
4 1" IT PDU Basic Switzerland (20 V / 0 Hz) 00.2 G 1. mm².0 T G 1.0 mm² T 00. G 1. mm².0 T2 1 T T2 Current per phase (A) T1 G 1.0 mm² Thermal fuse (A) Cable length (m) 00. Cable type H0VV-F G 1.0 mm² T 00. G 1. mm².0 T Mains and frequency filters 00.1 G 1.0 mm² T G 1. mm².0 T " IT PDU Basic UK (20 V / 0 Hz) Current per phase (A) UK 1.0 G 1. mm² UK 1 G 1. mm² UK Cable length (m).0 Cable type H0VV-F " IT PDU Basic France (20 V / 0 Hz). Terminal RCD 0 ma UTE Miniature circuit breaker Cable type: m H0VV-F G 1.0 mm² Current per phase: 1 A Mains and frequency filters.0.0. With fuse.0.0 B1.0 Pictograms and their meaning can be found on page 2.
5 IT PDU Basic 1 U Vertical For future-proofed, highly efficient power distribution in data centres, server racks and network racks. The high-quality and very robust aluminium profile measures a compact x mm. The space-saving design therefore provides space for data cabling and ventilation for cooling the server rack. BENEFITS Space-saving integration of PDU into the server rack with scope for modular add-ons High-quality and very robust aluminium profile Phases identified by colour PDU with single or double infeed to increase performance or to create redundancies, up to A per PDU Customised and country-specific solutions in series quality on request IEC020 C1 with IEC Lock The IEC Lock system protects computers, as servers and electrical equipment can become accidentally disconnected due to vibrations. IEC020 C1, lockable Two locking clips to secure two connection cables. IEC020 C1 with IEC Lock available as an option. Pictograms and their meaning can be found on page 2.
6 Dimensions (mm). x x.1 * 2. x x 11.0 * x x x x * 1 1 Cable type H0VV-F- Miniature circuit breaker C1A Phases G 2. mm² G 2. mm² Cable length (m) C1 x x 20 with locking clips 0. 2 C1 / Power distribution units 1 A / 20 V / 0 Hz 1" 1 A / 00 V / 0 Hz G 2. mm² 1 A / 00 V / 0 Hz 00.0 G 2. mm² G 2. mm² G 2. mm² 00.0 G 2. mm² 00.1 G 2. mm² x G 2. mm² 2x 2 x WEF** x G 2. mm² 2x 2 x WEF** G 2. mm² G 2. mm² 00.2 G 2. mm² x x x x. 2 x x x x x x x x x x x x 1.1 * G 2. mm² 1 x x G 2. mm² 11 x x G 2. mm² 2 1 x x G 2. mm² 2 1 x x x x x x A / 20 V / 0 Hz G mm² G mm² A / 00 V / 0 Hz G mm² * x x G mm² * 20 x x x x x x x x G mm² 00.2 G mm² 00.0 G mm² For IEC020 and earthing contact plug connection cables available in / to distinguish from power supply (A/B), see page 1. * C1 with IEC lock **WEF = ferrules Pictograms and their meaning can be found on page 2.
7 IT PDU Basic >1 U ALU Power distribution units Torsionally rigid profile > 1 U (2 mm), profile depth mm Modular socket design Standard socket colour white; other colours, yellow, red, brown, blue and green also available Optionally with illuminated 2-pole switch High-quality electronic components, e.g. type III overvoltage protection, mains and frequency filters Mounting brackets included End caps riveted and not openable 1" PDU >1 U ALU (20 V / 0 Hz) Dimensions / Power input: m, H0VV-F G 1.0 mm2 Grey With moulded right-angled plug with dual earthing contact system Current per phase: 1 A set at 0 x 2 x mm. 0 x 2 x mm x 2 x mm.0 0 x 2 x mm.0 0 x 2 x mm x 2 x mm Mains and frequency filters Pictograms and their meaning can be found on page 2.
8 IT PDU Basic >1 U PVC Power distribution units Torsionally rigid profile > 1 U (2 mm) in high-quality PVC, profile depth mm Optionally with illuminated 2-pole switch Light colour similar to RAL0 High-quality electronic components, e.g. type III overvoltage protection, mains and frequency filters Mounting brackets included End caps riveted and not openable 1" PDU >1 U PVC (20 V / 0 Hz) Dimensions / Power input: m, H0VV-F G 1.0 mm2 Grey With moulded right-angled plug with dual earthing contact system Current per phase: 1 A set at 0 x 2 x mm.0 0 x 2 x mm.0 0 x 2 x mm. 0 x 2 x mm. 0 x 2 x mm Mains and frequency filters.02 Stainless steel mounting bracket.02 Fitted at various heights and angles by fastening in the slots of the end cap. Pictograms and their meaning can be found on page 2. 21
9 IT power distribution Power distribution units (PDU) Accessories Accessories 2. BlueNet BN2000 / BN2000 PLC 2.2 Temperature sensor 0 m cable 2. Combination temperature and air humidity sensor 0 m cable BlueNet BN000 BN00 sensors 00 GPIO module on request 01 Including m CAT e supply cable with RJ plug on both ends 01 Temperature sensor.0 02 Combination temperature and air humidity sensor interlocks 0. Locking clips C1 2-way Red Set for C1 outlets.2 00 Interlock C1/C1 universal height ( pieces) SecureSleeve C1 Red pieces SecureSleeve C1 Black pieces. 0.1 SecureSleeve C20 Red pieces. 0.1 SecureSleeve C20 Black pieces Locking cap IEC020 C1 & C C1 locking caps items incl. unlocking tool C1 locking caps items incl. unlocking tool Unlocking tool for locking cap RackFix tool-free mounting on 1" rail Self-locking fixing connector for tool-free mounting of PDUs in 1" rack Mounting clip, supplied in packs of Disassembly tool for fixing clip Pictograms and their meaning can be found on page 2.
10 IT power distribution Power distribution units (PDU) Accessories Shift inhibitor To protect against unintentional actuation of miniature circuit breakers and residual current devices 0.10 Activation lock for circuit breakers and switches 1-pole To protect against unauthorised or dangerous activation of the switch lever Mounting kits for IT PDUs The brackets are screwed to the PDU end cap using a screw connection (screws provided) 0.12 Mounting brackets left and right (1 U). 0.0 Mounting brackets left and right (>1 U) Mounting brackets for vertical / universal mounting profile variants Power strip is fixed by inserting into the profile groove provided No additional screws required 0.11 Mounting brackets left and right (1 U) Mounting brackets left and right (1 U) for vertical mounting Link for connecting two vertically mounted PDUs (1 U) Replacement mounting accessories (BN000 BN00) 0001 Universal mounting kit Mounting kit, rear Mounting kit, side Universal mounting kit with double holder 0001 on request Mounting options 000 Pictograms and their meaning can be found on page 2. 2
English IT power distribution Professional power supply concepts
English 2008 IT power distribution Professional power supply concepts Bachmann IT power distribution Bachmann IT power distribution Optimise your power management for maximum benefit. Bachmann provides
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air
More informationPDU - Overview / Non-Intelligent PDU s
PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement
More informationPower Distribution Unit
414 Simple assembly Compact design Toolless clip attachment in the TS-IT Flexible mounting at the required height in the zero-u space lso suitable for individual installation on the enclosure frame Reliable
More informationModular PDU Smart metering for your IT
Modular PDU Smart metering for your IT Extremely flexible The modular PDU 2 Rittal modular PDU Modern IT equipment is constantly evolving, requiring permanent adjustments to the IT infrastructure. With
More informationStripes. 19" Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS...
Stripes 19" Outlet Stripes... 90 Desktop Outlet Stripes... 93 IP Power Distribution Units... 94 IP Monitoring Units... 95 UPS... 96 19" Outlet Stripes DIGITUS 19" outlet strip with switch, 7 outlets DIGITUS
More informationSpecification Sheet: HT SERIES
Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationInsulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals
Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals Technical Data Type: KS 4401 KS 4402 KS 4403 KS 4461 KS 4404 KS 440 KS 4406 Article number * ) : 00636 00637 0063987 00614
More informationENGLISH / 2016 KITCHEN SOLUTIONS. Modern integration of power for kitchens. It's electric.
ENGLISH / 2016 KITCHEN SOLUTIONS Modern integration of power for kitchens It's electric. KITCHEN SOLUTIONS Contents Plug into a world of opportunities The new BACHMANN power strips for kitchens are the
More informationPlexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.
Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable
More informationInForm Superstructures
Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices
More informationIncremental Encoder with Hollow Shaft
Incremental Encoder Type RI 36-H n miniature industry encoder for high number of pulses n short mounting length n easy mounting procedure n Application e.g.: - Motors - Machine tools - Packaging Machines
More informationInForm Superstructures
Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices
More informationtopter SERIES ACTIVE PROTECTION Leading Electrotechnology
topter SERIES ACTIVE PROTECTION Leading Electrotechnology topter series Active protection Industrial sockets splash proof and watertight IP44, IP66/IP67 product specifications Conformity to standards EN
More informationPlexo IP 55/IP 66 Makes your day, rain or shine
Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable
More informationIT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...
IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access
More informationhotels 2016/2017 It's electric. English
hotels 06/07 It's electric. English Our goal here at BACHMANN is to be a trendsetter and to bring innovations to life. We want to improve quality of life with our solutions people should feel at ease
More informationMBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit
MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationIt s electric. COMPLETE CATALOGUE 2013 / 2014 Innovative products for the professional user. ENGLISH / 2013/14
ENGLISH / 2013/14 Electrical materials IT power distribution Manufacturing Facility systems COMPLETE CATALOGUE 2013 / 2014 Innovative products for the professional user. It s electric. BACHMANN / Complete
More informationProbably the fastest enclosure in the world
95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationRCMB20/RCMB Series
4 T M /-500 Series Integratable Ground Fault Monitoring Modules For Integration Into Frequency Converters and Combiner Boxes Technical Bulletin NAE1042510 / 10.2012 BENDER Inc. 700 Fox Chase, Coatesville
More informationComplete catalogue We power your life. English
Complete catalogue 2017 We power your life English Peter Bachmann CEO Dear reader, to promote Life Quality at all levels of interaction is our company goal. Particularly in times when economic and social
More informationInnovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s
Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power
More informationEco IndustryLine Single-module functional lighting
Single-module functional lighting Single-module functional lighting with connection box or 5.00 m / 10.00 m cable Ceiling surface-mounted luminaire made of robust aluminium housing (painted RAL 9006) based
More informationMEASURING AND TESTING INSTRUMENTS
MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at
More informationRCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions
RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection
More informationVEROTEC Electronics Packaging
VEROTEC Electronics Packaging KM6-HD Subracks Introduction: KM6-HD subracks KM6-HD HEAVY DUTY CARD FRAME Introduction The KM6-HD subrack system, although primarily designed for military use, would suit
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationPERFECT HANDLING. PCB Front Panels & Injector/Extractor Handles... Package Your Electronics With Ripac.
Front Panels & Injector/Extractor Handles... PERFECT HANDLING. Package Your Electronics With Ripac. When it comes to electronics, no one handles today s demanding applications better than Rittal Ripac
More information3: Handles. 3.1 Fluted Handles C 3_ Rigid-Mounted Unit Handles C 3_ Ejector Handles acc. to IEC C 3_4
3.1 Fluted Handles 3_2 3.2 Rigid-Mounted Unit Handles 3_3 3.3 Ejector Handles acc. to IE 3_4 3.4 Injector/Ejector Handles acc. to IEEE 3_6 3.4.1 Ergonomic IEEE Standard Injector/Ejector Handle 3_6 3.4.2
More informationYourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.
This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free. Your PDU 3..7 1. 2. Our advanced technology offers you accurate measurements and detailed data, so that
More informationModule 18plus. Description. 18plus
Module 8plus Description Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control
More informationComplete Catalogue English
Complete Catalogue 09 English Peter Bachmann CEO OPPORTUNITIES Dear reader, At the beginning of the last century the economist John Maynard Keynes said: The difficulty lies not in the new ideas, but in
More informationLOW VOLTAGE DEVICES PLUGS AND CONNECTORS
LOW VOLTAGE DEVICES PLUGS AND CONNECTORS SCHUKO Plugs and Connectors SCHUKOultra Plugs and Connectors 10 SCHUKOultra Three-Way Connectors 11 SCHUKO Rubber Plugs and Connectors 12 SCHUKO Solid Rubber Plugs
More informationDIGITUS Server Cabinet Unique Series
15 Years Product Warranty kg loading capacity Modular aluminum frame construction large range of equipment available Overview DIGITUS Server Cabinet Unique Series 600, 800 mm width mm depth Features Safety
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationProtect Circuit Protection
Circuit Protection Product Catalogue 2018 Protect Circuit Protection Deta s new range of domestic Circuit Protection provides a high quality and cost effective solution, perfect for both new build and
More informationBasic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12
01-02 Basic PDU 03-04 Modules 05-06 SW Meter PDU 07-08 SW Meter Switch PDU 09-10 SW Three Phase PDU 11-12 How to install Safewell Basic PDU Series Model:SW-1U-8IEC13-K Product Description Size 19 * 1U
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationManual Clamps for Automotive Prototype Production
Manual Clamp interchangeable with 82M-6 This newest version provides more clamp arm variations and in addition two hold open devices. Opening angle can be reduced now. Page 15.2 New products 15.0 Notes
More informationComplete catalogue We power your life. English
Complete catalogue 2018 We power your life. English Peter Bachmann CEO The power of the community Dear reader, The power of the community is the focus of our corporate philosophy. However, what does community
More informationfor a perfect electrical installation. The range of rail-mounted terminal blocks
The range of rail-mounted terminal blocks for a perfect electrical installation. The range of rail-mounted terminal blocks for a perfect electrical installation. The new standard for rail-mounted terminal
More informationPDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions
PDU A AUSTI POWER 3 PHASE WSI WI WS W MD BASIC Temperature & Humidity Sensors A pair of sensors can be connected to one single W series PDU meter. 3 PHASE Free Management Software Manager enhances the
More informationDIN Rail Mounted Terminals & Accessories
DIN Rail Mounted Terminals & Accessories PAGE PAGE STANDARD CONTA-CONNECT RANGE 253 NEW! CABLECRAFT ABS-S ENCLOSURES 260 DOUBLE & TRIPLE CONTA-CONNECT RANGE 254 NEW! CABLECRAFT ALUMINIUM ENCLOSURES 260
More information2 PIECE BOARD-TO-BOARD
2 PIECE BOARD-TO-BOARD 201-01-123 1. SPECIFICATION DISTRIBUTION No restrictions for issue 2. SCOPE This specification contains the application notes for the 9159 two part connectors. 3. PRODUCTS 10-9159
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More information454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA
454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology
More informationAccessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)
25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The
More informationLimanda. Technical data
Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes: 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and stationary
More informationEuropacpro Industrial Applications
Europacpro Industrial Applications for industrial applicationsdmain Catalogue Subracks EuropacPRO for Industrial Applications OVERVIEW MAIN KATALOG Cabinets....... 1 Wall mounted cases......... 2 Accessories
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationArticle no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC
Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category
More informationMAINS DISTRIBUTION UNIT MDU14-CO
MAINS DISTRIBUTION UNIT MDU14-CO Dual Input Auto Changeover 14 Output Mains Distribution Unit. Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200,
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More informationRoto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions
Roto E-Tec Electronic drive and control systems for windows and doors Installation instructions for detachable miniature cable junctions Liability exclusion All specifications in this brochure were diligently
More informationXPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output
Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation
More informationResidual Current Devices drcm Digital
Digital Line voltage independent RCCB for fault or additional protection with additional digital features. System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents.
More informationPower Distribution Units with 13A Sockets
Power Distribution Units with 13A Sockets The Olson Slim Range is ideal for wall or floor mounting and available in 10 different sizes. Standard Specifications Includes: Red neon "mains on" indicator Brackets
More informationSwitches and Indicators 84
Switches and Indicators 84 84 Switches and Indicators Index Series 84 Description Page 177 Product Assembly Page 178 Mounting Instruction Page 179 Product Range - pushbuttons for flush mounting - accessories
More informationInstallation Manual for D1800 Series High Power PoE Midspan Power Supply
Installation Manual for D1800 Series High Power PoE Midspan Power Supply Dycon Power Solutions Ltd Tel: +44 (0)1443 471 900 Unit A - Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconpower.com
More informationModel KB 400 Cooling incubators with compressor technology
Model KB 400 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes
More informationPowerShield 8. Installation Manual
PowerShield 8 Installation Manual Table of Contents 1 Glossary... 4 2 Introduction... 5 3 Installation Quick Guide... 6 4 The PowerShield 8 Battery Monitoring System... 8 4.2 Controller... 10 4.2.1 Power
More informationModel KB 240 Cooling incubators with compressor technology
Model KB 240 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationem4 Accessories Digital expansions
em4 Accessories Digital expansions Up to two digital / analog expansions can be added to the em4 nanoplc to expand up to 46 I/Os 6 digital / analog configurable inputs (0-10 VDC, 0-28.8 VDC, Potentiometer)
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationhotels 2016/2017 It's electric. English
hotels 2016/2017 It's electric. English Our goal here at BACHMANN is to be a trendsetter and to bring innovations to life. We want to improve quality of life with our solutions people should feel at ease
More informationLimanda. Technical data
Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes - 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationinformation service Pag.1
Pag.1 TO SCAME CLIENTS List of new available products (Refer to Commercial Dept for item codes and prices) DATATEL Series Cat. 6 New products in DATATEL Series Components for RJ45 cat. 6 trasmission systems
More informationInterlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches
HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for
More informationComplete catalogue We power your life. English
Complete catalogue 08 We power your life. English Peter Bachmann CEO The power of the community Dear reader, The power of the community is the focus of our corporate philosophy. However, what does community
More informationmodular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security
aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,
More informationAPS4 Inductive Proximity Sensors
APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,
More informationNokeval. FD100 series. User Manual
Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device
More informationBlue e+ chillers with the principle
Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationF3ET Lightcurtain in robust aluminium housing
Lightcurtain in robust aluminium housing FET Lightcurtain in robust aluminium housing The FET lightcurtains provide a reliable area monitoring in a robust housing. The M2 -pin connectors and optical synchronisation
More informationSAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS
SAFE, FLEXIBLE, EASY FOR THE SAFE MEASUREMENT OF HIGH CURRENTS CURRENT TRANSFORMER CLIP-ON CORE-BALANCED OPEN-CORE FOR SAFE ENERGY ACQUISITION Camille Bauer and Gossen Metrawatt, your competent partners
More informationSensor boxes SRBG Key features
Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn
More informationR u b b e r d i s t r i b u t o r
Rubber distributor The modular rubber distributor series We live in a fast-moving time. It is also frequently necessary to make modifications to power distribution systems. Power distributors used in industrial
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital
More informationIS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours
IS Series Manual IS O Power IS Series Toroidal Isolation Power Conditioning 19 Pro Series Rack Mount (RK) Faceplate IS O Power IS Series Toroidal Isolation Power Conditioning 17 Consumer Series (C) Faceplate
More informationSafety. Detection. Control. MAGNUS RFID ENG - REV
03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide
More informationM12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector
M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45
More informationTROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K
.2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave
More informationSTG 2000 modules. Description
STG 2000 modules Description Description STG 2000 is the last evolution of STG range of connection modules. This module offers category 5 transmission performance as a standard. As a result this module
More informationExcel Power Distribution
www.excel-networking.com Excel Power Distribution Section 7 In this Section: Pages Power Distribution Units 154 Efficiency Measurements 154 Excel Modular PDU Range 155 Excel Standard PDUs 156 Excel Intelligent
More informationInstallation manual for for Schleifenbauer DPM3
Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationProduct and functional description
Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect
More informationAS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45
Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages
More informationNEW 74 PS RANGE. Push-buttons, selectors and indicators ø 22mm
NEW 74 PS RANGE Push-buttons, selectors and indicators ø 22mm 74 PS RANGE Push-buttons, selectors and indicators ø 22mm The 74 PS range: a system of push-buttons, selectors and indicators with a 22mm diameter
More information