Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Size: px
Start display at page:

Download "Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED"

Transcription

1 Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure or derived measured variables for gases or liquids in cryogenic service Measuring ranges from... 6 to... 6 mbar Nominal pressure PN 4 1) The Media 6 differential pressure meters are measuring and indicating devices for differential pressure and the measured variables derived from it. They are used to measure flow according to the differential pressure method and, above all, to measure the liquid level of pressure vessels. Cryogenic, liquified gases such as Ar, O 2, N 2, CO 2, H 2, He etc. are particularly suitable as process media. When used in combination with an appropriate power supply unit (e.g. Type from SAMSON) for the electric power supply or the Media LOGI-Compact hardware for remote data transmission, the tank content (function of hydrostatic pressure, tank geometry data and liquid density of the stored gas) is converted into a current signal from 4 to 2 ma proportional to the tank content and displayed on a LCD in the selected measuring unit. Additionally, limit values can be monitored and indicated. Remote transmission of all relevant Media 6 data is possible using the Type 527 Media LOGI-Compact hardware and the Type 517 Media LOGI-Base software. The tank data can be transmitted via a phone line and modem to a remote PC, where they are analyzed. When used in combination with an orifice plate assembly (Type 9/Type 91 Orifice Flange), the Media 6 devices can be used for continuous flow measurement of gases, vapors and liquids (differential pressure method). Special features Suitable for liquids, gases and vapors Microprocessor-controlled transmitter with RS-22 interface for configuration and programming on site Two adjustable software limit switches Gas selection by switch Programming via memory pen Digital display (LCD) for temperatures down to 4 C with 1% bar graph as well as alarm and warning markers Zero point and span adjustment activated via key without influencing each other Two-wire connection for standard current signal 4 to 2 ma Easy configuration using Type 6661 TROVIS-VIEW Overloadable on one side up to the permissible static pressure, indicating unit with burst protection Field unit with degree of protection IP 65 1) PN 5 on request 2) Others on request Media 6 with LCD Fig. 1 Media 6, versions Media 6 with LED Valve block directly connected (flange mounting) with operating pressure gauge Versions Media 6 with LCD Transmitter with digital display Two-wire system Output signal 4 to 2 ma, supply voltage 12 to 6 V DC, consisting of: LCD 9 mm with 1% bar graph and blinking alarm and warning markers Two software limit switches according to NAMUR Dp-cell made of CuZn4Pb or stainless steel (on request), PN 4 1) Free of oil and grease for oxygen Measuring ranges from 4 to 6 mbar Measuring diaphragm made of ECO 2) Zero point and span adjustment activated via key Process connections G 8 A RS-22 interface Media 6 with LED Transmitter with light emitting diode (LED) to signal specific operating states Versions as described above Additional to an already existing mechanical indicator and as a supplementary independent measuring device in installations with increased safety standards Media 6 optionally equippable with... Version as above, but for hazardous areas Input circuit with degree of protection II 2 G EEx ia II C T6 Directly connectable valve block (flange mounting) to check the pressure in the tank Remote tank monitoring with Media LOGI-Compact and Media LOGI-Base Associated Information Sheet T 95 EN Edition May 22 Data Sheet T 9527 EN

2 Principle of operation (Fig. 2) The measuring device consists of a dp-cell (1) with a measuring diaphragm (1.1), measuring springs (1.2) designed to correspond to the span, and the indicating unit (7) with an LCD or LED. The differential pressure p = p 1 p 2 causes a shift in the axis (1.5) of the measuring diaphragm (1.1) supported by the measuring springs (1.2). The change in travel, which is proportional to the differential pressure, is led through a lever (1.) and the elastic disk (1.4) out of the pressure chamber to the displacement sensor (2). This sensor converts the travel into an electric signal. The signal of the displacement sensor (2) is compared to the data stored in the EEPROM (4) and processed in the microprocessor (). It controls both the LCD or LED and the D/A converter (9) for the output signal. The output signal, which is proportional to the measured value, is a load-independent direct current signal from 4 to 2 ma available at male connector A. At male connector B, two software limit switches (8) for min. alarm (e.g. minimum filling level) and max. alarm (e.g maximum filling level) are connected to the switching amplifier according to DIN EN The RS-22 interface (1) enables the device to be configured with a special memory pen or directly via a PC with SAMSON s TROVIS-VIEW Configuration and Operator Interface. The userspecific data are saved in the EEPROM (4). This way, a backup copy of the data can be saved until they are overwritten. The operating data of the Media 6 can also be copied and loaded on site. The memory pen can be programmed using a PC and the corresponding SAMSON software TROVIS-VIEW with the operating data - type of gas, gas density, geometrical shape of the tank and location of the min./max limit switches. These details enable the conversion of the differential pressure into values which are proportional to the tank content to display and issue the direct current signal from 4 to 2 ma. Four types of gas as well as the span and write protection function can be set with the DIL switch (6). In combination with three keys (5), several operating functions (zero point and span adjustment, max. alarm limit switch and test function settings, etc.) as well as the operating status (load/save operating values) can be adjusted Indicating unit with LCD dp-cell Valve block with pressure gauge Indicating unit with LED µp Fig. Principle of operation m % 1 p _ 2 p 1 + Ar O 2 N 2 CO 2 EEPROM Span: Start - Value End - Valvue 9 Male connector A UB =12 to 6 V_ IA = 4 to 2 ma 8 Male connector B Max. alarm Min. alarm RS Light emitting diode Plate for gas types and measuring ranges H Fig. 2 Principle of level measurement for liquified gases in cryogenic service H h h Storage tank Ar, N2, O2, CO2, etc. Measuring range Measured level (~tank content) + Media 6 with valve block m % 1 p2 p1 1 dp-cell 1.1 Measuring diaphragm 1.2 Measuring spring 1. Lever 1.4 Elastic disk 1.5 Diaphragm axis 2 Displacement sensor Microprocessor 4 Memory (EEPROM) 5 Keys for operating functions 6 4-pin DIL switch - selection of gas type, span protection and write protection 7 Indicating unit with LCD 8 Limit switch 9 D/A converter 1 RS-22 interface 2 T 9527 EN

3 Table 1 Technical data All pressures stated in bar (gauge) or mbar Differential pressure measuring device Media 6 Measuring range to to to to mbar to 6 to 1 to 16 to 25 to 4 to 6 (Span 1:5 adjustable) Span min. 6 to 6 to 1 to 16 to 25 to 4to 6 to 1 to 16 to mbar Cl. 1.6 max Span min. mbar 1) 4 to 4 to 4 to 6 to 1 to 15 to 25 to 4 to 6 to 1to Cl. 2.5 max Nominal pressure PN 4 2), overloadable on one side up to 4 bar Display LCD 9 mm or LED mm Performance Output and display linear to the tank content Terminal based non-conformity < ±1.6 % or < ±2.5 % (including hysteresis) depending on the selected span Sensitivity <.25 % or <.5 % depending on the selected span Effect of static pressure <. % / 1 bar Influence of ambient temperature in the range from 2 to +7 C on zero point on span < ±.2 %/1 K < ±.2 %/1 K Limit switches 2 software limit switches (e.g. 1x min. alarm, 1x max. alarm) in acc. with NAMUR and DIN EN 5227 Control circuit, adjustable in 1% steps Rating according to the connected the switching amplifier ) in acc. with NAMUR and DIN EN 5227 Hysteresis 1 % related to the maximum tank capacity (MCN) 4) Range of inversion, approx. <.6% Degree of protection acc. to DIN VDE 47 IP 65 Weight without valve block with valve block Approx.. kg Approx. 5. kg Version Two-wire system Output 4 to 2 ma UB 12 V Perm. load RB in Ω R B = 2 ma Output current circuit Intrinsically safe (on request) Supply voltage UB for two-wire transmitter Ambient conditions Perm. ambient temperature range 12 to 6 VDC 4 to +7 C Perm. storage temperature range 4 to +8 C 1) When values fall below these measuring spans, the accuracy class Cl. 2.5 may be exceeded 2) Oxygen version up to PN 5 on request ) e.g. KFA6-SR2-Ex2.W (Co. Pepperl & Fuchs) 4) MCN = Maximum Capacity Nominal Note: All data about errors and deviations stated in % of the adjusted measuring span! 12 to 28 VDC - only in combination with an intrinsically safe circuit - T6; max. +6 C T5; max. +7 C Table 2 Materials Differential pressure measuring device Media 6 Version Standard version Special version dp-cell Cu Zn 4 Pb CrNi steel 1) Measuring diaphragm and seals ECO Measuring springs Diaphragm plates and function parts CrNi steel Lever Indicating unit Polycarbonate 1) On request T 9527 EN

4 Electrical connection In combination with a power supply unit (e.g. SAMSON Type 524) or the Media LOGI-Compact hardware, the tank content can be transmitted and shown with the direct current signal 4 to 2 ma, which is proportional to the tank content. Additionally, the limit switches can be monitored and signalized. Data can be transferred either directly to the control room or, in combination with the Type 527 Media LOGI-Compact hardware and the Type 517 Media LOGI-Base software, to the PC of the gas supplier via phone line and modem. Storage tank Ar, N2, O2, CO2, etc. Tank system Media 6 with valve block % m A B Control room Power supply unit e.g. Type 524 A B Control room Media LOGI- Compact RS - 22 Power supply 2 V~ Phone line Gas supplier Modem + + Switching amplifier acc. to DIN EN 5227 Switching amplifier acc. to DIN EN 5227 PC with software Media LOGI-Base Two-wire system with data transmission into the control room Fig. 4 Data transmission Two-wire system with remote tank monitoring system Type 527 Media LOGI-Compact and Type 517 Media LOGI-Base software Terminal assignment The Media 6 differential pressure meter is designed as a twowire system. Both the measuring signal from 4 to 2 ma and the necessary supply voltage U B = 12 to 6 V DC for the twowire transmitter are transmitted by the same pair of wires. The Media 6 is connected with the device s plug connector in accordance to DIN 465, Style 1, 4-pin. Male connector A Power supply unit ~ Male connector A Two-wire connection for standard current signal 4 to 2 ma Two-wire connection Perm. load R B = U B 12 V 2 ma in Ω The rated supply voltage U B = 24 V DC. Male connector B Switching amplifier The permissible voltage range at the Media 6 device plug is between 12 V and 6 V DC with regard to the supply lead resistance Male connector B Software limit switches Connection for two software limit switches to connect to the switching amplifier in accordance to NAMUR and DIN EN Software limit switches for switching amplifier acc. to DIN EN 5227 Fig. 5 Electrical connection, terminal assignment 4 T 9527 EN

5 Mounting On mounting, it is important to make sure that the Media 6 device is attached to pipes, walls or mounting plates free of vibration, for pipe mounting, use mounting material with clamp to attach it to a vertical or horizontal pipe; use mounting material without clamp for wall mounting, see dimensional diagram in Fig. 6 for panel mounting. We recommend installing a shut-off valve and additionally an equalizing valve in the measuring lines. For this purpose, the SAMSON product range includes a valve block (see T 9555 EN) which is directly connected (flange-mounted) to the Media 6. Wall/panel mounting using two threaded holes M 8 in the rear side of the measuring chamber or two bore holes 8. mm in the valve block. Pipe mounting with mounting material and clamp for attachment to a horizontal or vertical 2 pipe. Process medium connection: Tapped hole ISO 228 G 8. Dimensions in mm Ø11 M % m Control panel 6 Bore pattern for panel mounting 17 Two bore holes 8.5 mm for mounting to the rear side of the dp-cell for screws M Two bore holes 8.5 mm for mounting to the valve block Fig. 6 Dimensional diagram 5 T 9527 EN

6 Accessories (also see T 9555 EN) Valve block PN 4 for non-flammable gases Order no. Brass St. steel Others on request Pressure gauge ND 1, Cl. 1. acc. to DIN EN 87 S1 or S optionally 4/6/16/25/4 bar see T 9555 EN Others on request Screw gland according to customer specifications on request Remote data transmission Media LOGI-Compact Type 527 (hardware) Compact field modem for connection of max. 4 sensors Media LOGI-Base Type 517 (software) see T 951 EN Isolating switch amplifier acc. to DIN EN 5227 for connection to male connector B - also installed in IP 66 enclosure or in SAMSOMATIC alarm system on request - Order no. 2 channels, HE 2 V AC Others on request Power supply and indicator unit Type 524-1, with two floating limit switches Order no. HE 2 V AC HE 115 V AC HE 24 V AC Table Nomenclature for ordering - Complete the order no. according to the instrument version chosen - Order No. Versions Type 56 - Versions Media 6 for measuring contents 1 Protection for use in hazardous areas Without EEx ia IIC T6 1 Version Material Standard Cu Zn 4 Pb 2 Oxygen Cu Zn 4 Pb 2 1 Standard Stainless steel 2 Oxygen Stainless steel Measuring range Diaphragm material 6 mbar 2 1 mbar 16 mbar 4-52 ECO 4 25 mbar 5 4 mbar 6 6 mbar 7 1 mbar 4-7 ECO 2 16 mbar mbar ECO 6 mbar 2 Display and output LCD and output: 4 to 2 ma 1 LED and output: 4 to 2 ma 2 Details are required about the tank characteristic and the gas to be stored (as set out by the specification sheet for parameterization of the Media 6) so that the display proportional to tank content and the two-wire signal of 4 to 2 ma can be set by the manufacturer. Ordering text Indicating Digital Transmitter for Differential Pressure Media 6 Version Type 56 - Special version... Accessories... Specifications subject to change without notice. SAMSON AG MESS- UND REGELTECHNIK Weismüllerstraße 614 Frankfurt am Main Germany Phone Fax Internet: T 9527 EN

Mounting and Operating Instructions EB EN. Differential Pressure Meter Media 6 with LCD Media 6 with LED LED

Mounting and Operating Instructions EB EN. Differential Pressure Meter Media 6 with LCD Media 6 with LED LED Differential Pressure Meter Media 6 with LCD Media 6 with LED LED Media 6 with LCD and attached valve block (left), Media 6 with LED (right) Mounting and Operating Instructions EB 9527-1 EN Firmware A

More information

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission T 9510 EN Media 7 Differential Pressure Meter with remote data transmission Application Microprocessor-controlled transmitter with dp cell for measuring and indicating the differential pressure, pressure,

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication Series 3731 Electropneumatic Ex d Positioner Type 3731-5 with FOUNDATION TM Fieldbus communication Application Positioner for attachment to pneumatic control valves Travel: 3.6 to 200 mm Opening angle:

More information

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner Data Sheet T 8394 EN Series 3725 Type 3725 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to

More information

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.

More information

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action) Application Electric actuators designed for valves used in heating, ventilation and air-conditioning systems as

More information

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Series 3731 Type 3731-5 Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening

More information

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters Edition November 2003 Information Sheet T 6000 EN Proportional valves e/p Converters Type 6 66 626

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3731 Type Electropneumatic Ex d Positioner with HART communication Series 3731 Type 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner Series 3731 TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic on/off valves in safety-instrumented

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN Type 6150 AS-Interface Module Type 3372 Electropneumatic Actuator with AS-interface module Mounting and Operating Instructions EB 6150 EN Edition July 2013 Definition of the signal words used in these

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

Electropneumatic Positioner Type and Type with HART communication

Electropneumatic Positioner Type and Type with HART communication Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-adjusting, automatic

More information

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors Series 3730 Electropneumatic Positioner Type 3730-6 with HART communication and pressure sensors Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application P30-2 Pressure Transmitter Datasheet At a Glance *High Quality* 3 Years Warranty Premium Pressure Transmitter for gauge and pressure measurement with 3 years warranty High repeatability and long-term stability

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening angle 24 to

More information

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation d e v e l o p i n g s o l u t i o n s DE43 Data sheet Digital 2-channel transmitter for direct connection to bus-capable automation devices The bus-capable 2-channel transmitter is suitable for measuring

More information

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS Pressure transmitter/pressure switch PASCAL CS for food/pharmaceutical/biotechnology, Type series CS2110 Features Multifunctional pressure transmitter/pressure switch Hygienic case with no notches or indentations

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information

Bargraph for quick range overview The digital indicators provide a bargraph in addition to the digital display. This gives you all information Loop-Powered Digital Indicators 830 Loop-Powered Process Indicator The 830 loop-powered digital indicators are universally applicable. The range (either 0 to 20 ma or 4 to 20 ma) is simply selected via

More information

Level and temperature switch Nivotemp NT-M, NT-MD

Level and temperature switch Nivotemp NT-M, NT-MD Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Level and temperature switch Nivotemp NT-M, NT-MD

Level and temperature switch Nivotemp NT-M, NT-MD Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

Level measurement. Applications. Special features. Description

Level measurement. Applications. Special features. Description Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data

More information

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063

Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 Mechatronic pressure measurement Bourdon tube pressure gauge with electrical output signal Stainless steel, safety version, NS 63 Model PGT23.063 WIKA data sheet PV 12.03 for further approvals see page

More information

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS Pressure transmitter/pressure switch PASCAL CS for food/pharmaceutical/biotechnology,type series CS2110 Features Multifunctional pressure transmitter/pressure switch Hygienic case with no notches or indentations

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * * 09005318 DB_EN_DE44_LCD Rev. ST4-C 07/17 *09005318* Datasheet DE44 Digital 2-channel differential pressure switch/transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und

More information

Level sensor for monitoring the level of liquid media

Level sensor for monitoring the level of liquid media Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150

More information

Series Electropneumatic Positioner Type and Type with HART communication

Series Electropneumatic Positioner Type and Type with HART communication Series 3730 Electropneumatic Positioner Type 3730-2 and Type 3730-3 with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection Page 1/6 Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection Brief description Surface-mounting thermostats control and monitor thermal processes. Thermostats

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO. LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:

More information

General Specifications

General Specifications General Specifications Model RAGH Rotameter This type of Rotameter is designed for measurement of liquids and gases. The conical glass metering tube has a free rotating float. The mounting position is

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

Electronic pressure switch with display Model PSD-4

Electronic pressure switch with display Model PSD-4 Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine

More information

Electric Actuators with Process Controllers

Electric Actuators with Process Controllers Electric Actuators with Process Controllers TROVIS 5724-8 (without fail-safe action) TROVIS 5725-8 (with fail-safe action) For heating and cooling applications Application Electric actuators with integrated

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application, Type series CI4100 Features Application area Machinery construction Chemical and petrochemical industry General process technology Pressure transmitter

More information

FlexBar HRT Pressure Transmitter

FlexBar HRT Pressure Transmitter FlexBar HRT Pressure Transmitter 4...0 ma, -wire transmitter, HART communication Some hygienic connections conform to -A standards, FDA demands and EHEDG guidelines Configurable span, unit and damping

More information

Automation System TROVIS 5400 District Heating Controller TROVIS 5475

Automation System TROVIS 5400 District Heating Controller TROVIS 5475 Automation System TROVIS 5400 District Heating Controller TROVIS 5475 On-off or three-step controller designed for wall or panel mounting (Front frame dimensions: 144 mm x 96 mm) Application Controller

More information

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 Data sheet Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 The P500 / P507 / P550 utilizes the thin film strain gauge sensing technology, incorporating an hermetically

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive

More information

Level switch NS 10/NS 25..-AM

Level switch NS 10/NS 25..-AM Level switch NS 10/NS 25..-AM Fluidcontrol Oil tanks in lubrication and oil supply systems are often under overpressure compared to the ambient atmosphere. All oil moistened parts of devices mounted externally

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * *

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * * 09005351 DB_EN_DE45_LCD Rev. ST4-G 11/17 *09005351* Datasheet DE45 Digital differential pressure switch / transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und Regeltechnik

More information

Compact pressure switch for multiple actuators

Compact pressure switch for multiple actuators Comct pressure switch for multiple actuators GW A GW A/.0 Printed in Germany Edition 0.0 Nr. 90 Technical description The GW A pressure switch is a comct pressure switch as r EN 8 for DUNGS multiple actuators.

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

Automation System TROVIS 5400 District Heating Controller TROVIS 5476 Automation System TROVIS 5400 District Heating Controller TROVIS 5476 On-off or three-step controller designed for wall or panel mounting (dimensions of front frame: 44 mm x 96 mm) Application Self-optimizing,

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-2 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for diaphragm seal operation, Type series CI4330 Features Application area General process engineering Chemical and petrochemical industry General process

More information

FlexBar 3501 Pressure Transmitter

FlexBar 3501 Pressure Transmitter FlexBar 350 Pressure Transmitter 4...0 ma, -wire transmitter, HART communication (Optional) Stainless steel heavy duty housing with LC-Display (Optional) Configurable span, unit, damping and linearisation

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued! EElectronic Devices and Systems EK-87 Electronic Volume Corrector This product is discontinued! In brief EK-87 electronic volume corrector System volume corrector including integrated data storage device

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

Multi-range pressure and differential pressure transmitter

Multi-range pressure and differential pressure transmitter Page 1/6 Multi-range pressure and differential pressure transmitter Type 402005 Applications Ventilation Air conditioning Clean-room technology Flue draft mechanisms Filter monitoring Brief description

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

TROVIS-VIEW software TROVIS 6661

TROVIS-VIEW software TROVIS 6661 TROVIS-VIEW software TROVIS 6661 Application Uniform interface for configuration and operation of various smart SAMSON devices TROVIS-VIEW provides a uniform user interface that allows users to configure

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information