IBM Storwize V3700. Quick Installation Guide IBM GC

Size: px
Start display at page:

Download "IBM Storwize V3700. Quick Installation Guide IBM GC"

Transcription

1 IBM Storwize V3700 Quick Installation Guide IBM GC

2 Note Before using this information and the product it supports, read the following information: v The general information in Notices on page 69 v v The information in the Safety and environmental notices on page ix The information in the IBM Environmental Notices and User Guide (provided on a DVD) This edition applies to IBM Storwize V3700 and is valid until replaced by new editions. This edition replaces GC Copyright IBM Corporation 2012, US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

3 Contents Figures v Tables vii Safety and environmental notices... ix Safety notices and labels ix Caution notices for the Storwize V x Danger notices for Storwize V xii Special caution and safety notices xiv General safety xiv Handling static-sensitive devices xv Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE xvi Environmental notices xvi About this guide xvii Who should use this guide xvii Storwize V3700 library and related publications xvii How to order IBM publications xix Related websites xix Sending your comments xix How to get information, help, and technical assistance xix Chapter 1. Before you begin the installation Reviewing your packing slip Identify the hardware components Direct current power supply units Verify environmental requirements Review enclosure location guidelines Chapter 2. Installing the hardware NEBS compliant earth connection Installing the support rails Installing the enclosures Installing options in the control enclosure Opening the node canister Installing an 8 Gbps Fibre Channel 4-port host interface adapter Installing a 10 Gbps iscsi-fcoe 2-port host interface adapter Installing a 1 Gbps iscsi 4-port host interface adapter Installing a SAS 4-port host interface adapter.. 34 Installing an 8 GB cache memory update Closing the node canister Installing disk drives Connecting SAS cables to expansion enclosures.. 41 SAS cabling guidelines Connecting Ethernet cables to node canisters Connecting Ethernet cables to 1 Gbps iscsi 4-port host interface adapters Connecting fibre cables to a 10 Gbps iscsi-fcoe 2-port host interface adapter Connecting Fibre Channel cables to a Fibre Channel host interface adapter Connecting a control enclosure to a host Powering on the system Chapter 3. Configuring the system Checking your web browser settings for the management GUI User name and password for system initialization 55 Initializing the system with a Microsoft Windows computer Initializing the system with an Apple Macintosh computer Initializing the system with a Linux computer Configuring a Storwize V3700 system to be NEBS compliant Adding an expansion enclosure to an existing system Appendix A. Accessibility features for IBM Storwize V Appendix B. Where to find the Statement of Limited Warranty Notices Trademarks Homologation statement Electronic emission notices Federal Communications Commission (FCC) statement Industry Canada compliance statement Australia and New Zealand Class A Statement 72 European Union Electromagnetic Compatibility Directive Germany Electromagnetic Compatibility Directive 72 People's Republic of China Class A Statement.. 73 Taiwan Class A compliance statement Taiwan Contact Information Japan VCCI Council Class A statement Japan Electronics and Information Technology Industries Association Statement Korean Communications Commission Class A Statement Russia Electromagnetic Interference Class A Statement European Contact Information Taiwan Contact Information Index Copyright IBM Corp. 2012, 2015 iii

4 iv Storwize V3700: Quick Installation Guide

5 Figures 1. Rear view of a Storwize V3700 control enclosure 6 2. Data ports in the rear of the Storwize V3700 control enclosure Control enclosure support rails of a Storwize V3700 system Rear view of a Storwize V3700 expansion enclosure SAS ports and LEDs in rear view of a Storwize V3700 expansion canister Expansion enclosure support rails on Storwize V USB flash drive DC power supply unit connectors and indicators Rack mounting rails and screws Installing the rail spring Hole locations in the front of the rack Opening the hinge brackets Closing hinge brackets and installing rear screw Inserting the enclosure Removing a node canister Removing the canister cover Host interface adapter and SFP transceivers Installing 8 Gbps Fibre Channel 4-port host interface adapter Installing 10 Gbps iscsi-fcoe 2 port host interface adapter Installing 1 Gbps iscsi 4-port host interface adapter Installing SAS 4-port host interface adapter Where to install the cache memory update Installing memory module option Reinstalling the canister cover Installing a node canister Removing a filler panel Installing a drive Connecting the SAS cables SAS cable connectors Connecting the Ethernet cables Example configuration with two pairs of Ethernet cables connected to 1 Gbps iscsi 4-port host interface adapters Example configuration with two pairs of Ethernet cables connected to 10 Gbps iscsi-fcoe 2-port host interface adapters Example configuration with two Fibre Channel cables per canister Example configuration with four Fibre Channel cables per canister Mini SAS HD to Mini SAS HD cable Mini SAS HD to Mini SAS cable Example configuration with three SAS cables per canister Example configuration with two SAS cables connected to a SAS 4-port host interface adapter Expansion canister LEDs Node canister LEDs Copyright IBM Corp. 2012, 2015 v

6 vi Storwize V3700: Quick Installation Guide

7 Tables 1. IBM websites for help, services, and information xvii 2. Storwize V3700 library xviii 3. IBM documentation and related websites xviii 4. IBM websites for help, services, and information xx 5. Steps for different installation scenarios Storwize V3700 enclosures DC power supply LED indicators DC cable wire color coding DC power supply input requirements Direct current power replaceable units Selecting bracket pins for your rack Default user name and password for the management GUI Copyright IBM Corp. 2012, 2015 vii

8 viii Storwize V3700: Quick Installation Guide

9 Safety and environmental notices Review the safety notices, environmental notices, and electronic emission notices for IBM Storwize V3700 before you install and use the product. Suitability for telecommunication environment: This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. Here are examples of a caution and a danger notice: CAUTION: A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury. (C001) DANGER A danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury. (D002) Safety notices and labels To find the translated text for a caution or danger notice: 1. Look for the identification number at the end of each caution notice or each danger notice. In the preceding examples, the numbers (C001) and (D002) are the identification numbers. 2. Locate the IBM Systems Safety Notices with the user publications that were provided with the Storwize V3700 hardware. 3. Find the matching identification number in the IBM Systems Safety Notices. Then, review the topics concerning the safety notices to ensure that you are in compliance. 4. Optionally, read the multilingual safety instructions on the Storwize V3700 website. Go to search for Storwize V3700, and click the documentation link. Review the safety notices and safety information labels before using this product. To view a PDF file, you need Adobe Acrobat Reader. You can download it at no charge from the Adobe website: IBM Systems Safety Notices This publication contains the safety notices for the IBM Systems products in English and other languages. Anyone who plans, installs, operates, or services the system must be familiar with and understand the safety notices. Read the related safety notices before you begin work. Note: The IBM System Safety Notices document is organized into two sections. The danger and caution notices without labels are organized alphabetically by language Copyright IBM Corp. 2012, 2015 ix

10 in the Danger and caution notices by language section. The danger and caution notices that are accompanied with a label are organized by label reference number in the Labels section. Note: You can find and download the current IBM System Safety Notices by searching for Publication number G in the IBM Publications Center. The following notices and statements are used in IBM documents. They are listed in order of decreasing severity of potential hazards. Danger notice definition A special note that emphasizes a situation that is potentially lethal or extremely hazardous to people. Caution notice definition A special note that emphasizes a situation that is potentially hazardous to people because of some existing condition, or to a potentially dangerous situation that might develop because of some unsafe practice. Note: In addition to these notices, labels might be attached to the product to warn of potential hazards. Finding translated notices Each safety notice contains an identification number. You can use this identification number to check the safety notice in each language. To find the translated text for a caution or danger notice: 1. In the product documentation, look for the identification number at the end of each caution notice or each danger notice. In the following examples, the numbers (D002) and (C001) are the identification numbers. DANGER A danger notice indicates the presence of a hazard that has the potential of causing death or serious personal injury. (D002) CAUTION: A caution notice indicates the presence of a hazard that has the potential of causing moderate or minor personal injury. (C001) 2. After you download the IBM System Safety Notices document, open it. 3. Under the language, find the matching identification number. Review the topics about the safety notices to ensure that you are in compliance. Note: This product was designed, tested, and manufactured to comply with IEC , and where required, to relevant national standards that are based on IEC Caution notices for the Storwize V3700 Ensure that you understand the caution notices for Storwize V3700. Use the reference numbers in parentheses at the end of each notice, such as (C003) for example, to find the matching translated notice in IBM Systems Safety Notices. x Storwize V3700: Quick Installation Guide

11 CAUTION: The battery contains lithium. To avoid possible explosion, do not burn or charge the battery. Do not: Throw or immerse into water, heat to more than 100 C (212 F), repair or disassemble. (C003) CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during a relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building. v Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet. When possible, restore the rack cabinet to the configuration of the rack cabinet as you received it. If this configuration is not known, you must observe the following precautions. Remove all devices in the 32U position and above. Ensure that the heaviest devices are installed in the bottom of the rack cabinet. Ensure that there are no empty U-levels between devices installed in the rack cabinet below the 32U level. v If the rack cabinet you are relocating is part of a suite of rack cabinets, detach the rack cabinet from the suite. v If the rack cabinet you are relocating was supplied with removable outriggers they must be reinstalled before the cabinet is relocated. v Inspect the route that you plan to take to eliminate potential hazards. v Verify that the route that you choose can support the weight of the loaded rack cabinet. Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet. v Verify that all door openings are at least 760 x 230 mm (30 x 80 in.). v Ensure that all devices, shelves, drawers, doors, and cables are secure. v Ensure that the four leveling pads are raised to their highest position. v Ensure that there is no stabilizer bracket installed on the rack cabinet during movement. v Do not use a ramp inclined at more than 10 degrees. v When the rack cabinet is in the new location, complete the following steps: Lower the four leveling pads. Install stabilizer brackets on the rack cabinet. If you removed any devices from the rack cabinet, repopulate the rack cabinet from the lowest position to the highest position. v If a long-distance relocation is required, restore the rack cabinet to the configuration of the rack cabinet as you received it. Pack the rack cabinet in the original packaging material, or equivalent. Also lower the leveling pads to raise the casters off the pallet and bolt the rack cabinet to the pallet. (R002) CAUTION: v Rack is not intended to serve as an enclosure and does not provide any degrees of protection required of enclosures. v It is intended that equipment installed within this rack will have its own enclosure. (R005). Safety and environmental notices xi

12 CAUTION: Tighten the stabilizer brackets until they are flush against the rack. (R006) CAUTION: Use safe practices when lifting. (R007) CAUTION: Do not place any object on top of a rack-mounted device unless that rack-mounted device is intended for use as a shelf. (R008) CAUTION: If the rack is designed to be coupled to another rack only the same model rack should be coupled together with another same model rack. (R009) Danger notices for Storwize V3700 Ensure that you are familiar with the danger notices for Storwize V3700. Use the reference numbers in parentheses at the end of each notice, such as (C003) for example, to find the matching translated notice in IBM Systems Safety Notices. xii Storwize V3700: Quick Installation Guide

13 DANGER When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. v Do not open or service any power supply assembly. v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. v Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate. v Connect any equipment that will be attached to this product to properly wired outlets. v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described in the following procedures when installing, moving, or opening covers on this product or attached devices. To disconnect: 1. Turn off everything (unless instructed otherwise). 2. Remove the power cords from the outlets. 3. Remove the signal cables from the connectors. 4. Remove all cables from the devices. To connect: 1. Turn off everything (unless instructed otherwise). 2. Attach all cables to the devices. 3. Attach the signal cables to the connectors. 4. Attach the power cords to the outlets. 5. Turn on the devices. v Sharp edges, corners and joints might be present in and around the system. Use care when handling equipment to avoid cuts, scrapes and pinching. (D005) DANGER Heavy equipment personal injury or equipment damage might result if mishandled. (D006) DANGER Safety and environmental notices xiii

14 Racks with a total weight of > 227 kg (500 lb.), Use Only Professional Movers! (R003) DANGER Do not transport the rack via fork truck unless it is properly packaged, secured on top of the supplied pallet. (R004) DANGER Main Protective Earth (Ground): This symbol is marked on the frame of the rack. The PROTECTIVE EARTHING CONDUCTORS should be terminated at that point. A recognized or certified closed loop connector (ring terminal) should be used and secured to the frame with a lock washer using a bolt or stud. The connector should be properly sized to be suitable for the bolt or stud, the locking washer, the rating for the conducting wire used, and the considered rating of the breaker. The intent is to ensure the frame is electrically bonded to the PROTECTIVE EARTHING CONDUCTORS. The hole that the bolt or stud goes into where the terminal conductor and the lock washer contact should be free of any non-conductive material to allow for metal to metal contact. All PROTECTIVE EARTHING CONDUCTORS should terminate at this main protective earthing terminal or at points marked with. (R010) Special caution and safety notices This information describes special safety notices that apply to the Storwize V3700. These notices are in addition to the standard safety notices supplied and address specific issues relevant to the equipment provided. General safety When you service the Storwize V3700, follow general safety guidelines. Use the following general rules to ensure safety to yourself and others. v Observe good housekeeping in the area where the devices are kept during and after maintenance. v Follow the guidelines when lifting any heavy object: 1. Ensure that you can stand safely without slipping. 2. Distribute the weight of the object equally between your feet. 3. Use a slow lifting force. Never move suddenly or twist when you attempt to lift. 4. Lift by standing or by pushing up with your leg muscles; this action removes the strain from the muscles in your back. Do not attempt to lift any objects that weigh more than 18 kg (40 lb) or objects that you think are too heavy for you. v Do not perform any action that causes a hazard or makes the equipment unsafe. xiv Storwize V3700: Quick Installation Guide

15 v Before you start the device, ensure that other personnel are not in a hazardous position. v Place removed covers and other parts in a safe place, away from all personnel, while you are servicing the unit. v Keep your tool case away from walk areas so that other people cannot trip over it. v Do not wear loose clothing that can be trapped in the moving parts of a device. Ensure that your sleeves are fastened or rolled up above your elbows. If your hair is long, fasten it. v Insert the ends of your necktie or scarf inside clothing or fasten it with a nonconducting clip, approximately 8 cm (3 in.) from the end. v Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your clothing. Remember: Metal objects are good electrical conductors. v Wear safety glasses when you are hammering, drilling, soldering, cutting wire, attaching springs, using solvents, or working in any other conditions that might be hazardous to your eyes. v After service, reinstall all safety shields, guards, labels, and ground wires. Replace any safety device that is worn or defective. v Reinstall all covers correctly after you have finished servicing the unit. Handling static-sensitive devices Ensure that you understand how to handle devices that are sensitive to static electricity. Attention: Static electricity can damage electronic devices and your system. To avoid damage, keep static-sensitive devices in their static-protective bags until you are ready to install them. To reduce the possibility of electrostatic discharge, observe the following precautions: v Limit your movement. Movement can cause static electricity to build up around you. v Handle the device carefully, holding it by its edges or frame. v Do not touch solder joints, pins, or exposed printed circuitry. v Do not leave the device where others can handle and possibly damage the device. v While the device is still in its antistatic bag, touch it to an unpainted metal part of the system unit for at least two seconds. (This action removes static electricity from the package and from your body.) v Remove the device from its package and install it directly into your Storwize V3700, without putting it down. If it is necessary to put the device down, place it onto its static-protective bag. (If your device is an adapter, place it component-side up.) Do not place the device onto the cover of the Storwize V3700 or onto a metal table. v Take additional care when you handle devices during cold weather. Indoor humidity tends to decrease in cold weather, causing an increase in static electricity. Safety and environmental notices xv

16 Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE The following comments apply to IBM storage devices that have been designated as conforming to NEBS (Network Equipment-Building System) GR-1089-CORE. The equipment is suitable for installation at: v Network telecommunications facilities v Locations where the NEC (National Electrical Code) applies Note: Environmental notices v This product is not intended to connect directly or indirectly by any means whatsoever to interfaces of public telecommunications networks. v The ac-powered system does not require the use of an external surge protection device (SPD). v The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground. v The storage device (dc power) is intended to be installed in a Common Bonding Network (or mesh network) as described in GR-1089-CORE, Issue 5 or latest revision. This information contains all of the required environmental notices for IBM Systems products in English and other languages. The IBM Systems Environmental Notices ( information includes statements on limitations, product information, product recycling and disposal, battery information, flat panel display, refrigeration and water-cooling systems, external power supplies, and safety data sheets. xvi Storwize V3700: Quick Installation Guide

17 About this guide Who should use this guide This publication provides information that helps you install and initialize IBM Storwize V3700 systems. This guide is intended for installers of Storwize V3700 systems. Before configuring your system, ensure that you follow the procedures as listed. Be sure to gather IP addresses that you will need before you begin the installation. Storwize V3700 library and related publications Product manuals, other publications, and websites contain information that relates to Storwize V3700. IBM Knowledge Center for Storwize V3700 The information collection in the IBM Knowledge Center contains all of the information that is required to install, configure, and manage the system. The information collection in the IBM Knowledge Center is updated between product releases to provide the most current documentation. The information collection is available at the following website: pic.dhe.ibm.com/infocenter/storwize/v3700_ic/index.jsp Storwize V3700 library Unless otherwise noted, the publications in the library are available in Adobe portable document format (PDF) from a website. Click Search for publications to find the online publications you are interested in, and then view or download the publication by clicking the appropriate item. Table 1 lists websites where you can find help, services, and more information. Table 1. IBM websites for help, services, and information Website Directory of worldwide contacts Support for Storwize V3700 (2072) Support for IBM System Storage and IBM TotalStorage products Address storwize/v Each of the PDF publications in the Table 2 on page xviii library is also available in the IBM Knowledge Center by clicking the number in the Order number column: Copyright IBM Corp. 2012, 2015 xvii

18 Table 2. Storwize V3700 library Title Description Order number IBM Storwize V3700 Quick Installation Guide Storwize V3700 Installation Poster IBM Systems Safety Notices IBM Storwize V3700 Read First Flyer IBM Statement of Limited Warranty (2072) IBM License Agreement for Machine Code The guide provides instructions for unpacking your order and installing your system. The first chapter describes verifying your order, becoming familiar with the hardware components, and meeting environmental requirements. The second chapter describes installing the hardware and attaching data cables and power cords. The last chapter describes accessing the management GUI to initially configure your system. The installation poster provides an illustrated sequence of steps for installing the enclosure in a rack and beginning the setup process. The guide contains translated caution and danger statements. Each caution and danger statement in the Storwize V3700 documentation has a number that you can use to locate the corresponding statement in your language in the IBM Systems Safety Notices document. This document introduces the major components of the Storwize V3700 system and describes how to get started with the IBM Storwize V3700 Quick Installation Guide. This multilingual document provides information about the IBM warranty for machine type This multilingual guide contains the License Agreement for Machine Code for the Storwize V3700 product. G IBM documentation and related websites Table 3 lists websites that provide publications and other information about the Storwize V3700 or related products or technologies. The IBM Redbooks publications provide positioning and value guidance, installation and implementation experiences, solution scenarios, and step-by-step procedures for various products. Table 3. IBM documentation and related websites Website IBM Publications Center IBM Redbooks publications Address servlet/pbi.wss xviii Storwize V3700: Quick Installation Guide

19 Related accessibility information To view a PDF file, you need Adobe Reader, which can be downloaded from the Adobe website: How to order IBM publications Related websites The IBM Publications Center is a worldwide central repository for IBM product publications and marketing material. The IBM Publications Center offers customized search functions to help you find the publications that you need. Some publications are available for you to view or download at no charge. You can also order publications. The publications center displays prices in your local currency. You can access the IBM Publications Center through the following website: The following websites provide information about Storwize V3700 or related products or technologies: Type of information Storwize V3700 support Technical support for IBM storage products IBM Electronic Support registration Website Sending your comments Your feedback is important in helping to provide the most accurate and highest quality information. To submit any comments about this book or any other Storwize V3700 documentation, send your comments by to starpubs@us.ibm.com. Include the following information in your v Publication title v Publication form number v Page, table, or illustration numbers that you are commenting on v A detailed description of any information that should be changed How to get information, help, and technical assistance If you need help, service, technical assistance, or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. About this guide xix

20 Information IBM maintains pages on the web where you can get information about IBM products and fee services, product implementation and usage assistance, break and fix service support, and the latest technical information. For more information, refer to Table 4. Table 4. IBM websites for help, services, and information Website Directory of worldwide contacts Support for Storwize V3700 (2072) Support for IBM System Storage and IBM TotalStorage products Address Note: Available services, telephone numbers, and web links are subject to change without notice. Help and service Before calling for support, be sure to have your IBM Customer Number available. If you are in the US or Canada, you can call 1 (800) IBM SERV for help and service. From other parts of the world, see for the number that you can call. When calling from the US or Canada, choose the storage option. The agent decides where to route your call, to either storage software or storage hardware, depending on the nature of your problem. If you call from somewhere other than the US or Canada, you must choose the hardware option when calling for assistance. When calling IBM for service regarding the product, follow these guidelines for the hardware option: Software option Identify the Storwize V3700 product as your product and supply your customer number as proof of purchase. The customer number is a 7-digit number ( to ) assigned by IBM when the product is purchased. Your customer number should be located on the customer information worksheet or on the invoice from your storage purchase. If asked for an operating system, use Storage. Hardware option Provide the serial number and appropriate 4-digit machine type. For Storwize V3700, the machine type is In the US and Canada, hardware service and support can be extended to 24x7 on the same day. The base warranty is 9x5 on the next business day. Getting help online You can find information about products, solutions, partners, and support on the IBM website. To find up-to-date information about products, services, and partners, visit the IBM website at xx Storwize V3700: Quick Installation Guide

21 Before you call Make sure that you have taken steps to try to solve the problem yourself before you call. Some suggestions for resolving the problem before calling IBM Support include: v Check all cables to make sure that they are connected. v Check all power switches to make sure that the system and optional devices are turned on. v Use the troubleshooting information in your system documentation. The troubleshooting section of the information center contains procedures to help you diagnose problems. v Go to the IBM Support website at v3700 to check for technical information, hints, tips, and new device drivers or to submit a request for information. Using the documentation Information about your IBM storage system is available in the documentation that comes with the product. That documentation includes printed documents, online documents, readme files, and help files in addition to the information center. See the troubleshooting information for diagnostic instructions. The troubleshooting procedure might require you to download updated device drivers or machine code. IBM maintains pages on the web where you can get the latest technical information and download device drivers and updates. To access these pages, go to support/storwize/v3700 and follow the instructions. Also, some documents are available through the IBM Publications Center. Sign up for the Support Line Offering If you have questions about how to use and configure the machine, sign up for the IBM Support Line offering to get a professional answer. The maintenance supplied with the system provides support when there is a problem with a hardware component or a fault in the system machine code. At times, you might need expert advice about using a function provided by the system or about how to configure the system. Purchasing the IBM Support Line offering gives you access to this professional advice while deploying your system, and in the future. Contact your local IBM sales representative or your support group for availability and purchase information. About this guide xxi

22 xxii Storwize V3700: Quick Installation Guide

23 Chapter 1. Before you begin the installation Before you can begin installing your system, you must unpack and verify your order and make other preparations. The Quick Installation Guide contains a set of instructions to help you unpack and install your system. The guide is divided into three chapters. 1. The steps in Chapter 1, Before you begin the installation (the chapter you are now reading) involve verifying your order, becoming familiar with the hardware component terminology, and ensuring that you have met the environmental requirements. 2. The steps in Chapter 2, Installing the hardware, on page 19 involve installing the hardware and attaching the data cables and power cords. 3. Chapter 3, Configuring the system, on page 53 helps you create your configuration file and access the management GUI. The management GUI guides you through the initial configuration process. Important information: v This guide presumes that you have read the planning information regarding your physical environment that is available from the IBM Knowledge Center for Storwize V3700. v Ensure that any cables that you are supplying are available for installation. Installation scenarios Depending on your order, this documentation steps you through setting up your system for the following scenarios: v Setting up a new system that consists of a control enclosure only. In this case, you are not installing any expansion enclosures. v Setting up a new system that consists of a control enclosure and one or more expansion enclosures. v Adding an expansion enclosure to an existing system. In this case, you initially installed a control enclosure (and, optionally, one or more expansion enclosures). You want to add an expansion enclosure to your existing system. You do not need to power off the system. You can add an expansion enclosure while the system is operational. Table 5 lists the steps for each scenario. Table 5. Steps for different installation scenarios New system (control enclosure only) Reviewing your packing slip on page 5 Identify the hardware components on page 6 Verify environmental requirements on page 16 New system (control enclosure and one or more expansion enclosures) Reviewing your packing slip on page 5 Identify the hardware components on page 6 Verify environmental requirements on page 16 Adding expansion enclosures to an existing system Reviewing your packing slip on page 5 Verify environmental requirements on page 16 Review enclosure location guidelines on page 16 Copyright IBM Corp. 2012,

24 Table 5. Steps for different installation scenarios (continued) New system (control enclosure only) New system (control enclosure and one or more expansion enclosures) Adding expansion enclosures to an existing system Review enclosure location guidelines on page 16 Review enclosure location guidelines on page 16 Installing the support rails on page 19 1 Installing the support rails on page 19 Installing the support rails on page 19 Installing the enclosures on page 24 1 Installing the enclosures on page 24 Installing the enclosures on page 24 Connecting SAS cables to expansion enclosures on page 41 1 Connecting Ethernet cables to node canisters on page 44 Connecting SAS cables to expansion enclosures on page 41 Powering on the system on page Connecting Fibre Channel cables to a Fibre Channel host interface adapter on page 47 Connecting Ethernet cables to node canisters on page 44 Adding an expansion enclosure to an existing system on page Powering on the system on page 50 Connecting Fibre Channel cables to a Fibre Channel host interface adapter on page 47 Chapter 3, Configuring the system, on page 53 Powering on the system on page 50 Chapter 3, Configuring the system, on page 53 1 Complete these steps for each expansion enclosure that you add. Be familiar with the following information v See Caution notices for the Storwize V3700 on page x and Danger notices for Storwize V3700 on page xii for a summary of the situations that can be potentially hazardous to you. Before installing, read and understand the following caution and danger statements. 2 Storwize V3700: Quick Installation Guide

25 v Use safe practices when lifting. The fully populated enclosure weighs about 26 kg (57 lbs). At least two people are required to lift and install the enclosure into the rack or to remove an enclosure from the rack. CAUTION: Use safe practices when lifting kg ( lbs) kg ( lbs) 55 kg ( lbs) svc00146 (27) Also keep in mind that a rack full of equipment is extremely heavy. DANGER: Heavy equipment personal injury or equipment damage might result if mishandled. (D006) v The following general precautions should be observed, even though the power-on steps differ slightly from the directions that you will follow for this product: Chapter 1. Before you begin the installation 3

26 DANGER When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. Do not open or service any power supply assembly. Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate. Connect any equipment that will be attached to this product to properly wired outlets. When possible, use one hand only to connect or disconnect signal cables. Never turn on any equipment when there is evidence of fire, water, or structural damage. Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. Connect and disconnect cables as described in the following procedures when installing, moving, or opening covers on this product or attached devices. To disconnect: 1. Turn off everything (unless instructed otherwise). 2. Remove the power cords from the outlets. 3. Remove the signal cables from the connectors. 4. Remove all cables from the devices. To connect: 1. Turn off everything (unless instructed otherwise). 2. Attach all cables to the devices. 3. Attach the signal cables to the connectors. 4. Attach the power cords to the outlets. 5. Turn on the devices. Sharp edges, corners and joints might be present in and around the system. Use care when handling equipment to avoid cuts, scrapes and pinching. (D005) Tools needed A flat-blade screwdriver with a 7 mm (1/4 inch) head is the only tool needed for installation. 4 Storwize V3700: Quick Installation Guide

27 Reviewing your packing slip After you open your shipment, you must verify the contents against the packing slip. In each box, locate the packing slip. Verify that the items listed in the packing slip match what is in the box, and that any optional items that you ordered are included in the list. Your shipment might contain extra items, depending on the order. Note: If you purchased your equipment through a reseller, some of the options might be preinstalled. Contact your supplier for details. Use the following checklist to check off the items in your order as you verify that they are included in your shipment. v Control enclosure or expansion enclosure (Table 6): Table 6. Storwize V3700 enclosures. Machine type/model Feature code Part number Description C ACAN 2072L2C IBM Storwize V slot Dual Control Enclosure for 3.5-inch drives (AC power) E ACAS 2072LEU IBM Storwize V slot Expansion Enclosure for 3.5-inch drives (AC power) C ACBN 2072S2C IBM Storwize V slot Dual Control Enclosure for 2.5-inch drives (AC power) E ACBS 2072SEU IBM Storwize V slot Expansion Enclosure for 2.5-inch drives (AC power) DC ACDJ 2072T2C IBM Storwize V slot Dual Control Enclosure for 2.5-inch drives (DC power) DE ACDS 2072TEU IBM Storwize V slot Expansion Enclosure for 2.5-inch drives (DC power) Note: Models DC and DE run in a direct current (DC) power environment rather than the alternating current (AC) environment that is required by the other models in the range. The only differences between these models and the equivalent 24 slot AC power models are the power requirements and the power supply units that are installed in the enclosure. For more information about the DC power supply units, see Direct current power supply units on page 10. v Rack-mounting hardware kit: Two rails (right and left assembly) Two rail springs Two sets of rail-mount screws and alternative rail-mount pins (large and small) for non-ibm racks v Two power cords for connection to rack-mounted power distribution units v Drive bay blanking plates (installed in the enclosure) v Publications package (includes a USB flash drive that is used to initialize the system) Chapter 1. Before you begin the installation 5

28 Options applicable to control enclosures v Cache memory upgrade v Four-port 8 Gbps Fibre Channel host interface adapter with two small form-factor pluggable (SFP) transceivers installed v Two extra Fibre Channel SFP transceivers v Fibre Channel cables v SAS cables v Four-port 1 Gbps iscsi host interface adapter v Two-port 10 Gbps iscsi / FCoE host interface adapter v Drives v Power cords for connection to wall sockets Options applicable to expansion enclosures v Expansion enclosure attachment cables v Drives v Power cords for connection to wall sockets Identify the hardware components The following graphics identify the hardware components and port locations for the control enclosure and expansion enclosure on Storwize V3700 systems. Control enclosure components Figure 1 shows the rear view of a control enclosure and identifies the location of the power supply units and node canisters IN IN OK OK 2 v Figure 1. Rear view of a Storwize V3700 control enclosure Note: Figure 1 and Figure 2 on page 7 show an enclosure that is equipped with alternating current (AC) power supplies. Some enclosure enclosure models have direct current (DC) power supplies instead (see Reviewing your packing slip on page 5 for the model numbers). For more information about DC power supply units, see Direct current power supply units on page 10. Note: Figure 1 shows the node canisters in their initial configuration, with no host interface adapter options installed. Data ports 6 Storwize V3700: Quick Installation Guide

29 Figure 2 shows the rear view of a Storwize V3700 control enclosure and identifies the location of the ports IN IN 1 OK OK v Figure 2. Data ports in the rear of the Storwize V3700 control enclosure v 1 USB ports. Each canister has two USB ports. One port is used during installation. v 2 Ethernet ports. Each canister has two 1 Gbps Ethernet ports. Port 1 Port 2 Must be connected for system management. Can optionally be used for iscsi host connectivity. Optional. Can be used for iscsi host connectivity or to provide an alternative (redundant) management address. v 3 Serial-attached SCSI (SAS) ports. Each canister has four SAS ports. Ports 1 to 3 are optionally used for connecting to host systems. Port 4 is optionally used for connecting to expansion enclosures. Control enclosure support rails The left and right control enclosure support rails (Figure 3 on page 8) are designed specifically for installation of a control enclosure. v The ledge on the inside of the rails supports the entire length of a control enclosure. v At the rear end of the control enclosure support rail, the top edge curves over to capture the top edge of an inserted control enclosure. This prevents the installed control enclosure bouncing when the rack is subjected to quake or vibration. v The control enclosure support rails adjust to fit racks from 685 mm to 765 mm deep, measured between the front and rear rack rails. Chapter 1. Before you begin the installation 7

30 fab10051 Figure 3. Control enclosure support rails of a Storwize V3700 system Expansion enclosure components Figure 4 shows the location of the power supply units and expansion canisters. v 1 Expansion canisters v 2 Power supply units IN IN OK OK 2 v Figure 4. Rear view of a Storwize V3700 expansion enclosure Note: Figure 4 shows an enclosure that is equipped with alternating current (AC) power supplies. Some enclosure models have direct current (DC) power supplies instead (see Reviewing your packing slip on page 5 for the model numbers). For more information about DC power supply units, see Direct current power supply units on page 10. Figure 5 on page 9 shows the LEDs and SAS port locations from the rear view of an expansion canister. v 1 LEDs v 2 SAS ports 8 Storwize V3700: Quick Installation Guide

31 v Figure 5. SAS ports and LEDs in rear view of a Storwize V3700 expansion canister Each canister has two SAS ports that are numbered 1 on the left and 2 on the right. Port 1 is always used. Port 2 is used only if this is not the last enclosure in the chain. Expansion enclosure support rails The left and right expansion enclosure support rails (Figure 6) are designed specifically for installation of an expansion enclosure. v The ledge on the inside of each rail supports the entire length of an expansion enclosure. v The expansion enclosure support rails capture the left and right rear edges of an inserted expansion enclosure. This prevents the installed control enclosure bouncing when the rack is subjected to quake or vibration. v The expansion enclosure support rails adjust to fit racks from 595 mm to 755 mm deep, measured between the front and rear rack rails. fab10053 Figure 6. Expansion enclosure support rails on Storwize V3700 Chapter 1. Before you begin the installation 9

32 Miscellaneous hardware The USB flash drive (Figure 7) is packaged with the publications and contains the initialization tool for completing the initial system configuration. svc00646 Figure 7. USB flash drive Direct current power supply units Some Storwize V3700 enclosure models run in a direct current (DC) power environment rather than the alternating current (AC) environment required by the other models in the range. This section describes the additional information you need to know when using the DC power models. DANGER Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) DANGER 10 Storwize V3700: Quick Installation Guide

33 When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product. v Do not open or service any power supply assembly. v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. v Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate. v Connect any equipment that will be attached to this product to properly wired outlets. v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described in the following procedures when installing, moving, or opening covers on this product or attached devices. To disconnect: 1. Turn off everything (unless instructed otherwise). 2. Remove the power cords from the outlets. 3. Remove the signal cables from the connectors. 4. Remove all cables from the devices. To connect: 1. Turn off everything (unless instructed otherwise). 2. Attach all cables to the devices. 3. Attach the signal cables to the connectors. 4. Attach the power cords to the outlets. 5. Turn on the devices. v Sharp edges, corners and joints may be present in and around the system. Use care when handling equipment to avoid cuts, scrapes and pinching. (D005) Statement 19: CAUTION: The power-control button on the device does not turn off the electrical current supplied to the device. The device also might have more than one Chapter 1. Before you begin the installation 11

34 connection to DC power. To remove all electrical current from the device, ensure that all connections to dc power are disconnected at the DC power input terminals. OFF Statement 34: CAUTION: To reduce the risk of electric shock or energy hazards: v This equipment must be installed by trained service personnel in a restricted-access location, as defined by the NEC and IEC , First Edition, The Standard for Safety of Information Technology Equipment. v Connect the equipment to a properly grounded safety extra low voltage (SELV) source. A SELV source is a secondary circuit that is designed so that normal and single fault conditions do not cause the voltages to exceed a safe level (60 V direct current). v Incorporate a readily available approved and rated disconnect device in the field wiring. v See the specifications in the product documentation for the required circuit-breaker rating for branch circuit overcurrent protection. v Use copper wire conductors only. See the specifications in the product documentation for the required wire size. v See the specifications in the product documentation for the required torque values for the wiring-terminal screws. Note: In Statement 34 above: v Replace IEC , First Edition with IEC , Second Edition Amendment 1. v The required circuit breaker rating is 20 amps. DC power supply unit connectors and indicators Each Storwize V3700 enclosure contains two DC power supply units. Each power supply unit can provide power to the whole enclosure. The power supply units have the components that are shown in Figure 8 on page Storwize V3700: Quick Installation Guide

35 v v 1 Release tab v 2 Handle Table 7. DC power supply LED indicators v 3 Power supply LED indicators v 4 DC power cable connector Each power supply also contains fans that cool the enclosure. Cool air is drawn in through the front of the enclosure. The air passes over the drives, node canisters, and power supplies. The warmed air is ejected through the rear of each power supply. For optimal cooling, do not obstruct the airflow and ensure that all enclosure components or fillers are installed while the system is operational. DC power supply LED indicators Each power supply unit has four LED indicators. Table 7 summarizes their possible values and meaning. The LEDs have a comparable meaning to the LEDs on the AC power supply. Problem diagnosis and service procedures are the same. For details, see Powering on the system on page 50. Name Label Color State Description Input status IN Green OFF No input power detected. Output status ON DC input power detected. Green OFF PSU is not providing DC output power. ON Fault Amber OFF No fault detected. (None) OK Figure 8. DC power supply unit connectors and indicators ON BLINK Blue N/A Not used. PSU is providing DC output power. PSU fault was detected. PSU is being identified. A fault might have been detected. Connecting a DC power supply to a DC power source A Storwize V3700 enclosure that is DC powered contains two DC power supply units (PSUs). Each unit must be connected to a suitable -48V DC power source. To provide redundancy in a power circuit failure, connect the two PSUs to different DC power sources. Chapter 1. Before you begin the installation 13

36 Table 8. DC cable wire color coding Color Blue Green / Yellow Use the supplied cables to connect the DC PSUs to the power sources. Use only the IBM supplied DC power cable (IBM part number 00AR087) to connect the unit to a DC power source. Each PSU cable must be protected by a 20A circuit breaker. These instructions assume that the circuit breaker is separate from the DC power distribution unit. Refer to the DC power distribution unit documentation and the circuit breaker documentation for details. Follow the instructions that are given there for connecting the circuit breaker to the power distribution unit and for connecting the DC power cable to the circuit breaker. One end of the cable ends in a plug that fits the DC PSU. At the other end of the cable, each individual wire ends with a 6 mm diameter ring terminal that is designed to fit an M6 stud. Provide adequate strain relief after you attach the ring terminals to the power source. Table 8 lists the wire colors. Function Return Ground Brown -48V Table 9. DC power supply input requirements The DC power cable is 4 m long. Connect it to the DC power source before you connect it to the PSU. The PSU does not have a power switch, so its outputs and the enclosure become live as soon as power is connected. The supplied power must meet the input requirements that are listed in Table 9. Requirement Min Max Voltage (V DC) Instantaneous (V DC for < 1 second) Inrush current at initial turn on (-48V DC) Out of spec time before power off is signaled 34 A 5 ms The connection to the DC power source must be made by trained service personnel. Ensure that the connection is made in accordance with all the requirements of the equipment that is being used. The DC power cable must be totally contained in a single rack and must not extend outside the rack to another rack. If it is necessary to replace the ring terminals with a different connector, choose a suitably sized and rated UL-listed connector that is appropriate for the wire gauge and available current. Install the ring terminals according to the instructions provided by the manufacturer. Direct current power replaceable units The DC power supply model has two replaceable units. 14 Storwize V3700: Quick Installation Guide

37 Table 10. Direct current power replaceable units Description FRU part number Customer replaced Direct current power supply 00AR231 Y Direct current power cable 00AR087 Y The procedure to remove and replace the DC power supply unit is the same as the AC power supply procedure. When replacing the DC power cable, follow the instructions for disconnecting cables from the DC power distribution unit. Chapter 1. Before you begin the installation 15

38 Verify environmental requirements The environmental and electrical requirements for the physical site must be met to ensure that your system works reliably. Before installing a Storwize V3700 system, you must verify that adequate space in a suitable rack is available. You must also ensure that the requirements for power and environmental conditions are met. This guide assumes that you have completed the physical planning for the environment of your system. If you have not done the environmental planning for your system, see the Storwize V3700 physical installation planning topic in the IBM Knowledge Center for Storwize V3700. Review enclosure location guidelines 16 Storwize V3700: Quick Installation Guide Before you install the enclosures, you must be familiar with these enclosure location guidelines. Installing a control enclosure only If you are installing a control enclosure only, follow these guidelines. v Position the enclosure in the rack so that you can easily view it and access it for servicing. v Locate the enclosure low enough for the rack to remain stable. v Ensure that you provide a way for two or more people to install and remove the enclosure. Installing a control enclosure and one or more expansion enclosures If you are installing a control enclosure plus one or more expansion enclosures, follow these guidelines. v Each Storwize V3700 enclosure to be installed requires 2U of rack space. v Each assembled enclosure weighs more than 18 kg. Provide sufficient space at the front of the rack for two persons to carry the enclosure safely. v Install all enclosures that constitute one system in contiguous positions in a rack. Place the control enclosure at the top. v Each control enclosure supports connection to up to nine expansion enclosures. If this system installation has fewer than nine expansion enclosures, reserve space directly below the system to allow future expansion. v If a rack is to be only partially filled, install the enclosures low enough for the rack to remain stable and enable easy access to the enclosures for servicing. Adding an expansion enclosure chain to an existing system If you are adding an expansion enclosure chain to an existing system, follow these guidelines. v You do not need to power off the system. You can add an expansion enclosure while the system is operational. v Add the first expansion enclosure directly below the control enclosure. v Add the second expansion enclosure directly above the control enclosure. v Add the third expansion enclosure directly below the first.

39 v Add the fourth expansion directly above the second, and so on. Chapter 1. Before you begin the installation 17

40 18 Storwize V3700: Quick Installation Guide

41 Chapter 2. Installing the hardware After verifying that you have all of the hardware components that you require, you can install them. You have completed the initial steps of verifying the shipping contents and becoming familiar with the hardware components. You have verified that the power and environmental requirements are met and have planned the location of the enclosures. You are now ready to begin installing the hardware components and connecting the data cables and power cords. NEBS compliant earth connection Installing the support rails When installing enclosures into a Network Equipment-Building System (NEBS) compliant installation, each enclosure must have a reliable electrical earth connection that is separate to any earth connections provided by power supply cables. On Storwize V3700 enclosures, this connection is made via the front enclosure mounting screws that are part of the standard installation described in Installing the support rails and Installing the enclosures on page 24. To provide a reliable electrical earth connection, the upright mounting rails of the racks into which enclosures are installed must meet the following requirements prior to installing the support rails and enclosures: v Upright mounting rails must not be painted, oxidized or otherwise insulated from the enclosure flanges and mounting rails. If paint, oxidization or other insulation is present, it must be removed and the metal must be brought to a bright, non-corroding finish. v Upright mounting rails must have their own NEBS compliant connection to earth, independent of the earth connections provided by any power supply cables. Note: If the Storwize V3700 system is required to be NEBS compliant, some system configuration settings must be made. For details, see Configuring a Storwize V3700 system to be NEBS compliant on page 62. Before installing an enclosure, you must first install support rails. About this task Note: For NEBS compliant installations, additional requirements are placed on the rack into which the support rails and enclosures are to be installed. Before proceeding, ensure that the rack meets the requirements listed in NEBS compliant earth connection. Procedure To install the support rails, complete the following steps. Copyright IBM Corp. 2012,

42 1. Locate the rack mounting rails and screws (Figure 9). The rail assembly consists of two rails that must be installed in the rack cabinet. v Figure 9. Rack mounting rails and screws 2. Remove the springs that are taped to one of the rails. 3. Attach a spring to the outside of each rail. a. Attach the circle end of the spring around the stud on the rail. (See Figure 10 on page 21.) b. Pulling on the spring, attach the hook end of the spring to the tab on the rail. 20 Storwize V3700: Quick Installation Guide

43 v Figure 10. Installing the rail spring 4. Working at the front of the rack cabinet, identify the two standard rack units (2U) of space in the rack into which you want to install the support rails. Figure 11 shows two rack units with the front mounting holes identified v Figure 11. Hole locations in the front of the rack v 1 Upper rail mounting bracket pin v 2 Lower rail mounting bracket pin Chapter 2. Installing the hardware 21

44 v 3 Rack mounting screw hole 5. Ensure that the appropriate bracket pins are installed in the front and rear bracket of each rail. Each rail comes with four medium pins preinstalled (two in the front bracket and two in the rear bracket). Large and small pins are provided separately. Use the pins that are appropriate for the mounting holes in your rack (see Table 11). Table 11. Selecting bracket pins for your rack Mounting holes Round, unthreaded Bracket pins Use the preinstalled medium pins. Round, threaded Unscrew the medium pins and replace with the smaller pins supplied with the rails. Square Unscrew the medium pins and replace with the large pins supplied with the rails. 6. At each end of the rail, grasp the tab 1 and pull firmly to open the hinge bracket (see Figure 12). 1 v Figure 12. Opening the hinge brackets 22 Storwize V3700: Quick Installation Guide

45 7. Align the holes in the rail bracket with the holes on the front and rear rack cabinet flanges. Ensure that the rails are aligned on the inside of the rack cabinet. 8. On the rear of the rail, press the two bracket pins into the holes in the rack flanges. 9. Close the rear hinge bracket to secure the rail to the rack cabinet flange. (See Figure 13.) v Figure 13. Closing hinge brackets and installing rear screw 10. On the front of the rail, press the two bracket pins into the holes in the rack flanges. 11. Close the front hinge bracket to secure the rail to the rack cabinet flange. (See Figure 13.) 12. Secure the rear of the rail to the rear rack flange with an M5 screw. (See Figure 13.) 13. Repeat the steps to secure the opposite rail to the rack cabinet. 14. Repeat the procedure to install rails for each additional enclosure. Chapter 2. Installing the hardware 23

46 Installing the enclosures Following your enclosure location plan, install the control enclosure (and optionally, one or more expansion enclosures). About this task Note: For NEBS compliant installations, more requirements are placed on the rack into which the support rails and enclosures are to be installed. Before you proceed, ensure that the rack meets the requirements that are listed in NEBS compliant earth connection on page 19. CAUTION: v To lift and install the enclosure into the rack requires at least two people. v Load the rack from the bottom up to ensure rack stability. Empty the rack from the top down. Procedure To install an enclosure, complete the following steps. 1. On either side of the drive assemblies, remove the enclosure end caps by grasping the handle and pulling the bottom of the end cap free, then clearing the tab on the top of the enclosure. 2. Align the enclosure with the front of the rack cabinet. 3. Carefully slide the enclosure into the rack along the rails until the enclosure is fully inserted (see Figure 14 on page 25). Note: The rails are not designed to hold an enclosure that is partially inserted. The enclosure must always be in a fully inserted position. 24 Storwize V3700: Quick Installation Guide

47 v Figure 14. Inserting the enclosure 4. Secure the enclosure with a screw in the rack mounting screw hole. 5. Reinstall the left and right end caps. (See Figure 14.) The left end cap has indicator windows that align with the status LEDs (light-emitting diodes) on the edge of the enclosure. a. Ensure that the serial number of the end cap matches the serial number on the rear of the enclosure. b. Fit the slot on the top of the end cap over the tab on the chassis flange. c. Rotate the end cap down until it snaps into place. d. Ensure that the inside surface of the end cap is flush with the chassis. Chapter 2. Installing the hardware 25

48 Installing options in the control enclosure If you have purchased host interface adapters or cache memory upgrades for your control enclosure and those options were not preinstalled for you, you must open each node canister and install the options. Note: You must install the same options in all node canisters. First, open the canister as described in Opening the node canister. Then refer to the procedure for the option you are installing. v Installing an 8 Gbps Fibre Channel 4-port host interface adapter on page 28 v Installing a 10 Gbps iscsi-fcoe 2-port host interface adapter on page 30 v Installing a 1 Gbps iscsi 4-port host interface adapter on page 32 v Installing a SAS 4-port host interface adapter on page 34 v Installing an 8 GB cache memory update on page 35 Finally, close the canister and install it in the control enclosure (see Closing the node canister on page 38). Note: Disk drives can also be installed in the control enclosure, but that procedure does not involve opening any node canisters. See Installing disk drives on page 40 for details. Opening the node canister Before you can install options in a node canister, you must gain access by opening the canister cover. Procedure To open the canister, complete the following steps. 1. If the canister is already installed in the enclosure, remove it as shown in Figure 15 on page 27. a. Unlatch the release levers and pull them open. The canister moves out of the slot approximately 0.6cm (0.25 inch). b. Slide the canister out of the enclosure. 26 Storwize V3700: Quick Installation Guide

49 IN OK IN OK v Figure 15. Removing a node canister 2. Turn the canister over and open the cover as shown in Figure 16. a. Press the recessed blue touch points on the cover. b. Slide the cover away from the thumbscrew end of the canister. v Figure 16. Removing the canister cover Chapter 2. Installing the hardware 27

50 Installing an 8 Gbps Fibre Channel 4-port host interface adapter If you purchased an FC ACHK 8 Gbps Fibre Channel 4-port host interface adapter that was not preinstalled for you, you must install it in the node canister. Before you begin The 8 Gbps Fibre Channel 4-port host interface adapter is installed in the node canisters in the control enclosure. If your control enclosure has two node canisters, you must install the same options in both canisters. Do not start installation until you have two of the 8 Gbps Fibre Channel 4-port host interface adapter options. About this task Note: The host interface adapter has four ports, but only two small form-factor pluggable (SFP) transceivers are installed. Procedure To install the host interface adapter, complete the following steps. 1. Remove the SFP transceivers from the host interface adapter (Figure 17). To remove an SFP transceiver, swing the release handle open and use it to pull the transceiver out of the port. v Figure 17. Host interface adapter and SFP transceivers 28 Storwize V3700: Quick Installation Guide

51 2. Loosen the retaining thumbscrew 1 as shown in Figure v Figure 18. Installing 8 Gbps Fibre Channel 4-port host interface adapter v 1 Retaining thumbscrew v 2 Filler handle v 3 Host interface adapter v 4 Catch slot 3. From inside the canister, grasp the filler handle 2 and slide the filler plate toward the thumbscrew to disengage the plate from the catch slot Remove the filler plate. 5. Insert the host interface adapter 3 into the canister as shown in Figure Align the mounting bracket of the host interface adapter with the inside of the host interface adapter aperture at the thumbscrew end of the canister, ensuring that the tab at the end of the faceplate is aligned with the catch slot Align the connecting edge of the host interface adapter with the slot in the host interface adapter connector inside the canister. Chapter 2. Installing the hardware 29

52 8. Apply pressure to the opposite edge of the host interface adapter to push the adapter into the connector. 9. Check that the host interface adapter is installed squarely in its slot and tighten the retaining thumbscrew Reinstall the SFP transceivers. To install a transceiver, push it fully into the port and close the release handle. 11. If you purchased the additional 2-transceiver option, install the extra SFP transceivers in the remaining ports. Installing a 10 Gbps iscsi-fcoe 2-port host interface adapter If you purchased an FC ACHM 10 Gbps iscsi-fcoe 2-port host interface adapter that was not pre-installed for you, you must install it in the node canister. Before you begin The 10 Gbps iscsi-fcoe 2-port host interface adapter is installed in the node canisters in the control enclosure. If your control enclosure has two node canisters, you must install the same options in both canisters. Do not start installation until you have two of the 10 Gbps iscsi-fcoe 2-port host interface adapter options. Procedure To install the host interface adapter, complete the following steps. 1. Remove each SFP transceiver from the host interface adapter. To remove an SFP transceiver, swing the release handle open and use it to pull the transceiver out of the port. 2. Remove the filler plate from the host interface adapter slot. a. Loosen the retaining thumbscrew 1 as shown in Figure 19 on page Storwize V3700: Quick Installation Guide

53 v Figure 19. Installing 10 Gbps iscsi-fcoe 2 port host interface adapter v 1 Retaining thumbscrew v 2 Filler handle v 3 Host interface adapter v 4 Catch slot b. From inside the canister, grasp the filler handle 2 and slide the filler plate toward the center of the canister to disengage the plate from the catch slot. c. Remove the filler plate. 3. Insert the 10 Gbps iscsi-fcoe 2-port host interface adapter 3 into the canister as shown in Figure Align the mounting bracket of the host interface adapter with the inside of the host interface adapter aperture (adjacent to the thumbscrew), ensuring that the tab at the end of the faceplate is aligned with the catch slot. 5. Align the connecting edge of the host interface adapter with the slot in the host interface adapter connector inside the canister. 6. Apply pressure to the opposite edge of the host interface adapter to push the adapter into the connector. Chapter 2. Installing the hardware 31

54 7. Check that the host interface adapter is installed squarely in its slot and tighten the retaining thumbscrew Reinstall the SFP transceivers that were removed in step 1 on page 30. To install a transceiver, push it fully into the port and close the release handle. Installing a 1 Gbps iscsi 4-port host interface adapter If you purchased an FC ACHL 1 Gbps iscsi 4-port host interface adapter that was not pre-installed for you, you must install it in the node canister. Before you begin The 1 Gbps iscsi 4-port host interface adapter is installed in the node canisters in the control enclosure. If your control enclosure has two node canisters, you must install the same options in both canisters. Do not start installation until you have two of the 1 Gbps iscsi 4-port host interface adapter options. Procedure To install the host interface adapter, complete the following steps. 1. Loosen the retaining thumbscrew 1 as shown in Figure 20 on page Storwize V3700: Quick Installation Guide

55 v Figure 20. Installing 1 Gbps iscsi 4-port host interface adapter v v v v 1 Retaining thumbscrew 2 Filler handle 3 Host interface adapter 4 Catch slot 2. From inside the canister, grasp the filler handle 2 and slide the filler plate toward the center of the canister to disengage the plate from the catch slot. 3. Remove the filler plate. 4. Insert the host interface adapter 3 into the canister as shown in Figure Align the mounting bracket of the host interface adapter with the inside of the host interface adapter aperture at the rear of the canister, ensuring that the tab at the end of the faceplate is aligned with the catch slot. 6. Align the connecting edge of the host interface adapter with the slot in the host interface adapter connector inside the canister. 7. Apply pressure to the opposite edge of the host interface adapter to push the adapter into the connector. 8. Check that the host interface adapter is installed squarely in its slot and tighten the retaining thumbscrew 1. Chapter 2. Installing the hardware 33

56 Installing a SAS 4-port host interface adapter If you purchased an FC ACHJ SAS 4-port host interface adapter that was not pre-installed for you, you must install it in the node canister. Before you begin The SAS 4-port host interface adapter is installed in the node canisters in the control enclosure. If your control enclosure has two node canisters, you must install the same options in both canisters. Do not start installation until you have two of the SAS 4-port host interface adapter options. Procedure To install the host interface adapter, complete the following steps. 1. Loosen the retaining thumbscrew 1 as shown in Figure v Figure 21. Installing SAS 4-port host interface adapter v v 1 Retaining thumbscrew 2 Filler handle 34 Storwize V3700: Quick Installation Guide

57 v v 3 Host interface adapter 4 Catch slot 2. From inside the canister, grasp the filler handle 2 and slide the filler plate toward the center of the canister to disengage the plate from the catch slot. 3. Remove the filler plate. 4. Insert the host interface adapter 3 into the canister as shown in Figure 21 on page Align the mounting bracket of the host interface adapter with the inside of the host interface adapter aperture at the rear of the canister, ensuring that the tab at the end of the faceplate is aligned with the catch slot. 6. Align the connecting edge of the host interface adapter with the slot in the host interface adapter connector inside the canister. 7. Apply pressure to the opposite edge of the host interface adapter to push the adapter into the connector. 8. Check that the host interface adapter is installed squarely in its slot and tighten the retaining thumbscrew 1. Installing an 8 GB cache memory update If you purchased an FC ACHB 8 GB Cache Update option that was not pre-installed for you, you must install it. Before you begin The 8 GB Cache Update option is installed in the node canisters in the control enclosure. If your control enclosure has two node canisters, you must install the same options in both canisters. Do not start installation until you have two of the Cache Update options. About this task The Cache Update option consists of a 4 GB memory module. When added to a node canister, it increases the total memory in the canister to 8 GB. The memory module is inserted into memory slot 2, located between the existing memory module and the battery (Figure 22 on page 36). Chapter 2. Installing the hardware 35

58 v Figure 22. Where to install the cache memory update Procedure To install the memory module option, complete the following steps. 1. Open the retaining clip on each end of the memory module connector as shown in Figure 23 on page 37. Attention: To avoid breaking the retaining clips or damaging the memory module connectors, open and close the clips gently. 36 Storwize V3700: Quick Installation Guide

59 v Figure 23. Installing memory module option 2. Touch the static-protective package that contains the memory module to any unpainted metal surface on the outside of the canister. 3. Remove the memory module from the package. 4. Turn the memory module so that the keys align correctly with the connector. 5. Insert the memory module into the connector by aligning the edges of the module with the slots at the ends of the connector (see Figure 23). 6. Firmly press the memory module straight down into the connector by applying pressure on both ends of the module simultaneously. The retaining clips snap into the locked position when the module is firmly seated in the connector. Note: If you can see a gap between the module and the retaining clips, the module has not been correctly inserted. Open the retaining clips, remove the module, and then reinsert it. Chapter 2. Installing the hardware 37

60 Closing the node canister After installing options in a node canister, you must close the canister cover and install the canister in the control enclosure. Procedure To close the canister, complete the following steps. 1. Reinstall the cover as shown in Figure 24. a. Align the four hook slots on the cover with the pins on the canister. b. Slide the cover toward the latch and release levers until it locks into place. v Figure 24. Reinstalling the canister cover 38 Storwize V3700: Quick Installation Guide

61 IN OK IN OK 2. Turn the canister over and install it in the control enclosure as shown in Figure 25. a. With the latch and release levers fully extended, slide the canister into the enclosure until the levers begin to move inwards. b. Simultaneously close both latch and release levers. v Figure 25. Installing a node canister Chapter 2. Installing the hardware 39

62 Installing disk drives If you purchased disk drives that were not preinstalled for you, you must install them. About this task Drives can be installed in the control enclosure or any of the expansion enclosures. The installation procedure is the same for either enclosure type. Install all the drives you require before configuring the system. This allows the best provisioning of drives into arrays. Procedure To install a drive, complete the following steps. 1. Remove the filler panel from the slot into which you want to install the drive (as shown in Figure 26). a. Grip the front of the filler panel 1 and pull firmly to remove it from the the drive slot. b. Save the filler panel for future use. 1 v Figure 26. Removing a filler panel v 1 Filler panel 2. Touch the static-protective package that contains the drive to any unpainted surface on the outside of the enclosure. 3. Remove the drive from the package. 40 Storwize V3700: Quick Installation Guide

63 4. Install the drive in the empty slot as shown in Figure 27. a. Ensure that the drive-tray handle is in the open (unlocked) position. b. Align the drive assembly with the guide rails in the slot. c. Gently push the drive assembly into the slot until the drive stops. d. Rotate the drive handle to the closed (locked) position. v Figure 27. Installing a drive Connecting SAS cables to expansion enclosures If you have installed expansion enclosures, you must connect them to a control enclosure. Before you begin If you purchased disk drives that were not preinstalled for you, you must install all of the drives before connecting the SAS cables to the expansion enclosures. About this task This task applies if you are installing one or more expansion enclosures. You can attach up nine expansion enclosures to the control enclosure. Note: When connecting SAS cables between enclosures, you must follow a list of guidelines to ensure that your configuration is valid. Do not begin connecting the cables until you have read SAS cabling guidelines on page 43. Chapter 2. Installing the hardware 41

64 Procedure To install the cables, complete the following steps. 1. Using the supplied SAS cables, connect the control enclosure to the first expansion enclosure as shown in Figure 28. a. Connect SAS port 4 of the left node canister in the control enclosure to SAS port 1 of the left expansion canisters in the first expansion enclosure. b. Connect SAS port 4 of the right node canister in the control enclosure to SAS port 1 of the right expansion canisters in the first expansion enclosure IN IN OK OK IN IN OK OK IN IN OK OK 1 2 v Figure 28. Connecting the SAS cables 42 Storwize V3700: Quick Installation Guide

65 2. If additional expansion enclosures are installed, connect each one to the previous expansion enclosure, as shown in Figure 28 on page 42. a. Use one cable to connect SAS port 2 of the left expansion canister in the previous expansion enclosure to SAS port 1 of the left expansion canister in the newly installed expansion enclosure. b. Use the second cable to connect SAS port 2 of the right expansion canister in the previous expansion enclosure to SAS port 1 of the right expansion canister in the newly installed expansion enclosure. Note: A control enclosure can support up to nine expansion enclosures. SAS cabling guidelines When connecting SAS cables between enclosures, you must follow a list of guidelines to ensure that your configuration is valid. Orienting the connector When inserting SAS cables, make sure the connector (Figure 29) is oriented correctly. v The orientation of the connector must match the orientation of the port before you push the connector into the port. The cable connector and socket are keyed, and it is important that you have proper alignment of the keys when the cable is inserted. v The blue pull tab must be below the connector. v Insert the connector gently until it clicks into place. If you feel resistance, the connector is probably oriented the wrong way. Do not force it. v When inserted correctly, the connector can only be removed by pulling the tab. v When both ends of a SAS cable are inserted correctly, the green link LEDs next to the connected SAS ports are lit. v Figure 29. SAS cable connectors Guidelines Be aware of the following guidelines when you attach the cables to the SAS ports. v No more than nine expansion enclosures can be chained to port 4 of a node canister. Chapter 2. Installing the hardware 43

66 6 6 v No cable can be connected between a port on a left canister and a port on a right canister. v A cable must not be connected between ports in the same enclosure. v Port 4 of a control enclosure is not cabled to another control enclosure. v Attach cables serially between enclosures. Do not skip an enclosure. v The last enclosure in a chain must not have cables in port 2 of canister 1 and port 2 of canister 2. v A connected port on the node canister must connect to a single port on an expansion canister. Cables that split the connector out into separate physical connections are not supported. v Ensure that cables are installed in an orderly way to reduce the risk of cable damage when replaceable units are removed or inserted. v Arrange your cables to provide access to the following items: USB ports USB port access is required when you use a USB flash drive to configure the system. Enclosures Access is required to the hardware for servicing and for safely removing and replacing components using two or more people. Connecting Ethernet cables to node canisters To provide system management connectivity for your Storwize V3700 system, you must connect Ethernet cables to Ethernet port 1 of each node canister in the control enclosure. This connection can optionally also be used for iscsi host connection. Ethernet port 2 can optionally be connected to provide a second system management address, a second iscsi host connection, or both. Procedure To install the Ethernet cables, complete the following steps. 1. Connect Ethernet port 1 of each node canister in the system to the IP network that will provide connection to the system management interfaces, as shown in Figure 30. This port can also be used for iscsi connectivity to the system by hosts on the network. Where more than one control enclosure is present in the system, ensure port 1 of every node canister is connected to the same network to provide access if the configuration node fails IN OK IN OK v Figure 30. Connecting the Ethernet cables 2. Optionally, connect Ethernet port 2 of each node canister in the system to a second IP network that will provide redundant connection to the system 44 Storwize V3700: Quick Installation Guide

67 management interfaces, as shown by the lighter cable connection in Figure 30 on page 44. This port can also be used for iscsi connectivity to the system by hosts on the network. If there is more than one control enclosure in the system, ensure that port 2 of every node canister is connected to the same network to provide access if the configuration node fails. Connecting Ethernet cables to 1 Gbps iscsi 4-port host interface adapters If you installed an optional 1 Gbps iscsi 4-port host interface adapter, you can use Ethernet cables to connect the system to your Ethernet SAN. About this task The Ethernet port numbering on the 4-port host interface adapter starts at 3, because Ethernet ports one and two are built into the canister. When a 4-port Ethernet host interface adapter is installed, the port number starts at 3. Note: The Ethernet cables are connected in pairs. Both canisters must have the same number of cables connected. Procedure To install the cables, complete the following steps. 1. Identify the correct pair of Ethernet cables for the Ethernet ports labeled 3 in the left canister and the right canister. 2. Connect the appropriate cable to each port. 3. For each additional pair of Ethernet ports in the right and left canisters, identify the correct pair of cables and connect them. Results Figure 31 shows an example configuration with a pair of Ethernet cables connected to port 3 in each canister, and another pair connected to port 4 in each canister IN IN OK OK v Figure 31. Example configuration with two pairs of Ethernet cables connected to 1 Gbps iscsi 4-port host interface adapters Connecting fibre cables to a 10 Gbps iscsi-fcoe 2-port host interface adapter If your Storwize V3700 system has 10 Gbps iscsi-fcoe 2-port host interface adapters installed, you can use fibre cables to connect them to your 10 Gbps Ethernet or FCoE SAN. Chapter 2. Installing the hardware 45

68 About this task The Ethernet port numbering on the host interface adapter starts at 3, because Ethernet ports one and two are built into the canister. Note: The fibre cables are connected in pairs. Both canisters must have the same number of cables connected. Procedure To install the cables, complete the following steps. 1. Identify the correct pair of fibre cables for the Ethernet ports that are labeled 3 in the left canister and the right canister. 2. Connect the appropriate cable to each port. 3. For each additional pair of Ethernet ports in the right and left canisters, identify the correct pair of cables and connect them. Results Figure 32 shows an example configuration. The figure shows a pair of Ethernet cables that are connected to port 3 in each canister, and another pair that is connected to port 4 in each canister TxRx TxRx 1 2 LNK LNK IN IN OK OK v Figure 32. Example configuration with two pairs of Ethernet cables connected to 10 Gbps iscsi-fcoe 2-port host interface adapters 46 Storwize V3700: Quick Installation Guide

69 4 4 Connecting Fibre Channel cables to a Fibre Channel host interface adapter If your Storwize V3700 system has 8 Gbps Fibre Channel 4-port host interface adapters installed, you can use Fibre Channel cables to connect them to your Fibre Channel SAN. Procedure To install the cables, complete the following steps. 1. Connect the required number of Fibre Channel cables. Refer to the Planning section of the IBM Knowledge Center for instructions on determining the number of cables required. Note: Both canisters must have the same number of cables connected. Figure 33 shows an example configuration with two Fibre Channel cables connected to each canister IN IN OK OK v Figure 33. Example configuration with two Fibre Channel cables per canister 2. If you want to connect additional Fibre Channel cables, make sure to connect the same number of cables to each canister. Figure 34 shows an example configuration with four Fibre Channel cables connected to each canister IN IN OK OK v Figure 34. Example configuration with four Fibre Channel cables per canister Connecting a control enclosure to a host When installing a control enclosure, you can connect it to a host with SAS cables. You can use onboard host SAS ports on some models or an optional SAS host interface adapter. Note that onboard SAS host ports are not available on all system models. Chapter 2. Installing the hardware 47

70 About this task Two types of SAS cables are used for host attachment, depending on the requirements of the host. v Mini SAS HD to Mini SAS HD (Figure 35) v Figure 35. Mini SAS HD to Mini SAS HD cable v Mini SAS HD to Mini SAS (Figure 36) ite00052 Figure 36. Mini SAS HD to Mini SAS cable Note: When inserting SAS cables, make sure that the connector is oriented correctly. v When connecting to the SAS ports on the left side of the node canister, the blue pull tab must be below the connector. v When connecting to a SAS 4-port host interface adapter, the blue pull tab must be above the connector. v Insert the connector gently until it clicks into place. If you feel resistance, the connector is probably oriented the wrong way. Do not force it. v When inserted correctly, the connector can only be removed by pulling the tab. Procedure To install the cables, complete the following steps. 48 Storwize V3700: Quick Installation Guide

71 1. Connect the required number of SAS cables. Refer to the Planning section of the IBM Knowledge Center for instructions on determining the number of cables required. Note: When connecting to the SAS ports on the left side of the node canister, each host must be connected to both canisters. Both canisters must have the same number of cables connected. 2. Arrange the cables to provide access to the hardware. v v Results USB ports. USB port access is required when you use a USB flash drive to configure the system. The enclosures themselves. Access is required to the hardware for servicing and for safely removing and replacing components using two or more people. Figure 37 shows an example configuration with three SAS cables that are connected to each canister IN IN OK OK v Figure 37. Example configuration with three SAS cables per canister Figure 38 shows an example configuration with two SAS cables that are connected to a SAS 4-port host interface adapter IN IN OK OK v Figure 38. Example configuration with two SAS cables connected to a SAS 4-port host interface adapter Chapter 2. Installing the hardware 49

72 Powering on the system After you install all hardware components, you must power on the system and check its status. About this task Attention: Do not power on the system with any open bays or slots. v Every unused drive bay must be occupied by a filler panel. v Filler panels must be installed in all empty host interface adapter slots. Open bays or slots disrupt the internal air flow, causing the drives to receive insufficient cooling. Procedure To power on the system, complete the following steps. 1. Power on all expansion enclosures. Use the supplied power cords to connect both power supply units of the enclosure to their power sources. If the power sources have circuit breakers or switches, ensure that they are turned on. The enclosure does not have power switches. Repeat this step for each expansion enclosure in the system. Note: Each enclosure has two power supply units. To provide power failure redundancy, connect the two power cords to separate power circuits. 2. From the rear of the expansion enclosure, check the LEDs on each expansion canister (see Figure 39) v Figure 39. Expansion canister LEDs 1 Power 2 Status 3 Fault The canister is ready with no critical errors when Power is illuminated, Status is on, and Fault is off. If a canister is not ready, refer to the Procedure: Understanding the system status using the LEDs topic in Troubleshooting. 3. Wait for all expansion canisters to finish powering on. 4. Power on the control enclosure. Use the supplied power cords to connect both power supply units of the enclosure to their power sources. If the power sources have circuit breakers or switches, ensure that they are turned on. The enclosure does not have power switches. Note: Each enclosure has two power supply units. To provide power failure redundancy, connect the two power cords to separate power circuits. 50 Storwize V3700: Quick Installation Guide

73 5. From the rear of the control enclosure, check the LEDs on each node canister (see Figure 40) v Figure 40. Node canister LEDs 1 Power 2 Status 3 Fault The canister is ready with no critical errors when Power is illuminated, Status is flashing, and Fault is off. If a canister is not ready, refer to the Procedure: Understanding the system status using the LEDs topic in Troubleshooting. Chapter 2. Installing the hardware 51

74 52 Storwize V3700: Quick Installation Guide

75 Chapter 3. Configuring the system Configuring your system is necessary in two situations: when you power up a new system for the first time, and when you add an expansion enclosure to an existing system. The following instructions use the supplied USB flash drive to initialize the system. If you are not authorized to use a USB flash drive in your situation, refer to the Troubleshooting section of the IBM Knowledge Center. This topic describes how to make an Ethernet connection to the enclosure and to initialize the system by using the service assistant GUI. After initializing the system, you will use the Storwize management GUI to complete the configuration procedures. v The management GUI requires a supported web browser (see Checking your web browser settings for the management GUI ). v To configure a new system, you will log on to the management GUI with the default user name and password (see User name and password for system initialization ). The steps for initializing a new system vary, depending on the operating system of the computer you use for the procedure. v For Microsoft Windows, refer to Initializing the system with a Microsoft Windows computer on page 57. v For Apple MacOS, refer to Initializing the system with an Apple Macintosh computer on page 59. v For Linux, refer to Initializing the system with a Linux computer on page 61. The steps for adding an expansion enclosure to an existing system are described in Adding an expansion enclosure to an existing system on page 62. Checking your web browser settings for the management GUI To access the management GUI, you must ensure that your web browser is supported and has the appropriate settings enabled. Before you begin The management GUI supports the following web browsers: v Mozilla Firefox 41 v Mozilla Firefox Extended Support Release (ESR) 38 v Microsoft Internet Explorer (IE) 11 and Microsoft Edge v Google Chrome 46 IBM supports higher versions of the browsers if the vendors do not remove or disable function that the product relies upon. For browser levels higher than the versions that are certified with the product, customer support accepts usage-related and defect-related service requests. If the support center cannot re-create the issue, support might request the client to re-create the problem on a certified browser version. Defects are not accepted for cosmetic differences between browsers or Copyright IBM Corp. 2012,

76 browser versions that do not affect the functional behavior of the product. If a problem is identified in the product, defects are accepted. If a problem is identified with the browser, IBM might investigate potential solutions or work-arounds that the client can implement until a permanent solution becomes available. Procedure To configure your web browser, follow these steps: 1. Enable JavaScript for your web browser. For Mozilla Firefox, JavaScript is enabled by default and requires no additional configuration. For Microsoft Internet Explorer (IE) running on Microsoft Windows 7: a. In Internet Explorer, click Tools > Internet Options. b. Click Security Settings. c. Click Internet to choose the Internet zone. d. Click Custom Level. e. Scroll down to the Scripting section, and then in Active Scripting, click Enable. f. Click OK to close Security Settings. g. Click Yes to confirm the change for the zone. h. Click OK to close Internet Options. i. Refresh your browser. For Microsoft Internet Explorer (IE) running on Microsoft Windows Server 2008: a. In Internet Explorer, click Tools > Internet Options. b. Click Security. c. Click Trusted sites. d. On the Trusted sites dialog, verify that the web address for the management GUI is correct and click Add. e. Verify that the correct web address was added to the Trusted sites dialog. f. Click Close on the Trusted sites dialog. g. Click OK. h. Refresh your browser. For Google Chrome: a. On the menu bar in the Google Chrome browser window, click Settings. b. Click Show advanced settings. c. In the Privacy section, click Content settings. d. In the JavaScript section, select Allow all sites to run JavaScript. e. Click OK. f. Refresh your browser. 2. Enable cookies in your web browser. For Mozilla Firefox: a. On the menu bar in the Firefox browser window, click Tools > Options. b. On the Options window, select Privacy. c. Set "Firefox will" to Use custom settings for history. d. Select Accept cookies from sites to enable cookies. e. Click OK. 54 Storwize V3700: Quick Installation Guide

77 f. Refresh the browser. For Microsoft Internet Explorer: a. In Internet Explorer, click Tools > Internet Options. b. Click Privacy. Under Settings, move the slider to the bottom to allow all cookies. c. Click OK. d. Refresh your browser. For Google Chrome: a. On the menu bar in the Google Chrome browser window, click Settings. b. Click Show advanced settings. c. In the Privacy section, click Content settings. d. In the Cookies section, select Allow local data to be set. e. Click OK. f. Refresh your browser. 3. Enable file download on IE 10 and 11 running on Windows a. In Internet Explorer, click Tools > Internet Options. b. On the Internet Options window, select the Security tab. c. On the Security tab, click the Internet zone. d. Click Custom level to customize the security level for this zone. e. Scroll down to Downloads and select Enable under File download. f. Click OK. g. Click Yes to confirm. h. Click OK to close the Internet Options. 4. Enable scripts to disable or replace context menus. (Mozilla Firefox only). For Mozilla Firefox: a. On the menu bar in the Firefox browser window, click Tools > Options. b. On the Options window, select Content. c. Click Advanced by the Enable JavaScript setting. d. Select Disable or replace context menus. e. Click OK to close the Advanced window. f. Click OK to close the Options window. g. Refresh your browser. 5. Enable TLS 1.1/1.2 (Microsoft Internet Explorer 9 and 10 only). For Microsoft Internet Explorer: a. Open Internet Explorer. b. Select Tools > Internet Options. c. Select the Advanced tab. d. Scroll to the Security section. e. Check the Use TLS 1.1 and Use TLS 1.2 checkboxes. Note: IE 11 and later enable TLS 1.1/1.2 by default. User name and password for system initialization During the initialization procedure, you need to log in to the management GUI for the Storwize V3700 system. Chapter 3. Configuring the system 55

78 The default user name and password for the management GUI are listed in Table 12. Table 12. Default user name and password for the management GUI User name superuser Password passw0rd Note: The 0 character in the password is the number zero, not the letter O. 56 Storwize V3700: Quick Installation Guide

79 Initializing the system with a Microsoft Windows computer To initialize a new system with a Microsoft Windows computer, use the initialization tool that was shipped with your order. Before you begin v Begin this procedure after you have installed all the enclosures, drives and other options you have purchased. v You need a Microsoft Windows computer to complete the initialization procedure. The computer must have: A USB port A supported browser For best results, the Microsoft Windows computer and the Storwize system must be connected to the same network. About this task This procedure is valid for Microsoft Windows 8.1 (64-bit) or Microsoft Windows 7 (64-bit). v Use this procedure only when initializing a new control enclosure (with, optionally, one or more expansion enclosures). v Do not use this procedure when adding an expansion enclosure to an existing system. Procedure To initialize the system, complete the following steps. 1. Gather the information you will use to configure the system. v v You must have the IP network address you will use to manage the system. IP address Subnet mask Gateway Other information is optional, but useful for enabling additional capabilities. The IP address of a Network Time Protocol (NTP) server for automated setting of date and time The IP address of a simple mail transfer protocol (SMTP) server for sending notification of alerts 2. Locate the USB flash drive that was shipped with your order in the documentation package. 3. Insert the USB flash drive into a USB port on the Microsoft Windows computer. 4. To launch the tool, open the USB flash drive. and double-click InitTool.bat The initialization tool wizard starts. 5. In the wizard, click Next and select Create a new system. 6. Follow the on-screen instructions given by the initialization tool. You will be instructed to complete the following actions: a. Enter the details of the system management address you need to use. b. Connect the USB flash drive to the Storwize system and allow it to initialize. c. Connect the USB flash drive to the computer to check that the initialization completed. Chapter 3. Configuring the system 57

80 7. If the system initialization completed successfully, click Finish. If you have a network connection to the Storwize system, the system management GUI is displayed. If the computer does not have a network connection to the Storwize system, go to the computer you will use to manage the system and start a supported browser. Direct the browser to the management address you specified for the system. 8. Log in with user name superuser and password passw0rd. Note: The 0 character in the password is a zero, not the letter O. 9. Follow the on-screen instructions to begin setting up your system. Note: The other options that are available in the initialization tool are used to recover the service IP address or the superuser password. 58 Storwize V3700: Quick Installation Guide

81 Initializing the system with an Apple Macintosh computer To initialize a new system with an Apple Macintosh computer, use the initialization tool that was shipped with your order. Before you begin v Begin this procedure after you have installed all the enclosures, drives and other options you have purchased. v You need an Apple Macintosh computer to complete the initialization procedure. The computer must have: A USB port A supported browser For best results, the Apple Macintosh computer and the Storwize system must be connected to the same network. About this task This procedure is valid for Apple MacOS X v Use this procedure only when initializing a new control enclosure (with, optionally, one or more expansion enclosures). v Do not use this procedure when adding an expansion enclosure to an existing system. Procedure To initialize the system, complete the following steps. 1. Gather the information you will use to configure the system. v You must have the IP network address you will use to manage the system. IP address Subnet mask Gateway v Other information is optional, but useful for enabling additional capabilities. The IP address of a Network Time Protocol (NTP) server for automated setting of date and time The IP address of a simple mail transfer protocol (SMTP) server for sending notificatication of alerts 2. Locate the USB flash drive that was shipped with your order in the documentation package. 3. Insert the USB flash drive into a USB port on the Apple Macintosh computer. 4. Open a terminal window. 5. Locate the root directory of the USB flash drive. The root directory is usually located in the /Volumes/ directory. 6. Type: sh InitTool.sh The initialization tool wizard starts. 7. In the wizard, click Next and select Create a new system. 8. Follow the on-screen instructions given by the initialization tool. You will be instructed to complete the following actions: a. Enter the details of the system management address you need to use. b. Eject the USB flash drive and remove it from the computer. Chapter 3. Configuring the system 59

82 c. Connect the USB flash drive to the Storwize system and allow it to initialize. d. Connect the USB flash drive to the computer to check that the initialization completed. 9. If the system initialization completed successfully, click Finish. If you have a network connection to the Storwize system, the system management GUI is displayed. If the computer does not have a network connection to the Storwize system, go to the computer you will use to manage the system and start a supported browser. Direct the browser to the management address you specified for the system. 10. Log in with user name superuser and password passw0rd. Note: The 0 character in the password is a zero, not the letter O. 11. Follow the on-screen instructions to begin setting up your system. Note: The other options in the initialization tool are used to reset the service IP address or the superuser password. 60 Storwize V3700: Quick Installation Guide

83 Initializing the system with a Linux computer To initialize a new system with a Linux computer, use the initialization tool that was shipped with your order. Before you begin v Begin this procedure after you have installed all the enclosures, drives and other options you have purchased. v You need a Linux computer to complete the initialization procedure. The computer must have: A USB port A supported browser For best results, the Linux computer and the Storwize system must be connected to the same network. About this task This procedure is valid for Red Hat Enterprise Server 5 and 6 or Ubuntu desktop and v Use this procedure only when initializing a new control enclosure (with, optionally, one or more expansion enclosures). v Do not use this procedure when adding an expansion enclosure to an existing system. Procedure To initialize the system, complete the following steps. 1. Gather the information you will use to configure the system. v You must have the IP network address you will use to manage the system. IP address Subnet mask Gateway v Other information is optional, but useful for enabling additional capabilities. The IP address of a Network Time Protocol (NTP) server for automated setting of date and time The IP address of a simple mail transfer protocol (SMTP) server for sending notificatication of alerts 2. Locate the USB flash drive that was shipped with your order in the documentation package. 3. Insert the USB flash drive into a USB port on the Linux computer. 4. Open a terminal window. 5. Locate the root directory of the USB flash drive. It is usually located in the /media/ directory. If an automatic mount system is used, the root directory can be located by typing the mount command. 6. Type: sh InitTool.sh The initialization tool wizard starts. 7. In the wizard, click Next and select Create a new system. 8. Follow the on-screen instructions given by the initialization tool. You will be instructed to complete the following actions: a. Enter the details of the system management address that you need to use. Chapter 3. Configuring the system 61

84 b. Connect the USB flash drive to the Storwize system and allow it to initialize. c. Connect the USB flash drive to the computer to check that the initialization completed. 9. If the system initialization completed successfully, click Finish. If you have a network connection to the Storwize system, the system management GUI is displayed. If the computer does not have a network connection to the Storwize system, go to the computer that you will use to manage the system and start a supported browser. Direct the browser to the management address you specified for the system. 10. Log in with user name superuser and password passw0rd. Note: The 0 character in the password is a zero, not the letter O. 11. Follow the on-screen instructions to begin setting up your system. Note: The other options that are available in the initialization tool are used to recover the service IP address or the superuser password. Configuring a Storwize V3700 system to be NEBS compliant For operation in Network Equipment-Building System (NEBS) compliant installations, the Storwize V3700 system can be configured to extend its operational temperature range to meet NEBS operating temperature requirements. Note: The Storwize V3700 system might not be able to save its cache and state data if the power fails while it is operating within the extended temperature range. This is because the battery capacity decreases as temperature rises. If the save of cache and state data cannot be completed, an extended service action is required to recover the system and data might be lost. Keep the temperature within the normal operating range if possible, and maintain a reliable power supply. v To extend the operational temperature range of all enclosures in the system to meet NEBS operating temperature requirements, enter the following CLI command: chsystem -hightempmode on Once set, high_temp_mode will be be applied to all enclosures in the system. v To configure the default operating temperature ranges, enter the following CLI command: chsystem -hightempmode off v To determine which mode is currently configured, read the value of the high_temp_mode parameter in the lssystem output. Note: Configuring the Storwize V3700 system to be NEBS compliant only changes the way the system responds to raised temperature. You must also ensure that the way the system is racked, and the operating environment, conforms to NEBS requirements. (See NEBS compliant earth connection on page 19.) Adding an expansion enclosure to an existing system When you add an expansion enclosure to an existing system, you must use the Storwize management GUI to update the system configuration. 62 Storwize V3700: Quick Installation Guide

85 About this task The management GUI requires a supported web browser (see Checking your web browser settings for the management GUI on page 53). Procedure To add an expansion enclosure to your system, complete the following steps. 1. Install support rails for the new enclosure. 2. Install the new enclosure in the rack. 3. Connect the expansion enclosure attachment cables. 4. Connect the power cables and wait for the SAS light-emitting diodes (LEDs) to illuminate. 5. Start the management GUI. 6. Go to Monitoring > System. 7. On the System page, select Actions > Add Enclosures. 8. Continue to follow the on-screen instructions. Chapter 3. Configuring the system 63

86 64 Storwize V3700: Quick Installation Guide

87 Appendix A. Accessibility features for IBM Storwize V3700 Accessibility features help users who have a disability, such as restricted mobility or limited vision, to use information technology products successfully. Accessibility features These are the major accessibility features for the Storwize V3700: v You can use screen-reader software and a digital speech synthesizer to hear what is displayed on the screen. HTML documents have been tested using JAWS version v This product uses standard Windows navigation keys. v Interfaces are commonly used by screen readers. v Industry-standard devices, ports, and connectors. The Storwize V3700 online documentation and its related publications are accessibility-enabled. The accessibility features of the online documentation are described in Viewing information in the information center. Keyboard navigation You can use keys or key combinations to perform operations and initiate menu actions that can also be done through mouse actions. You can navigate the Storwize V3700 online documentation from the keyboard by using the shortcut keys for your browser or screen-reader software. See your browser or screen-reader software Help for a list of shortcut keys that it supports. IBM and accessibility See the IBM Human Ability and Accessibility Center for more information about the commitment that IBM has to accessibility. Copyright IBM Corp. 2012,

88 66 Storwize V3700: Quick Installation Guide

89 Appendix B. Where to find the Statement of Limited Warranty The Statement of Limited Warranty is available in both hardcopy format and in the Storwize V3700 information center. The Statement of Limited Warranty is shipped (in hardcopy form) with your product. It can also be ordered from IBM (see Table 2 on page xviii for the part number). Copyright IBM Corp. 2012,

90 68 Storwize V3700: Quick Installation Guide

91 Notices This information was developed for products and services offered in the US. This material might be available from IBM in other languages. However, you may be required to own a copy of the product or product version in that language in order to access it. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-ibm product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not grant you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY U.S.A. For license inquiries regarding double-byte character set (DBCS) information, contact the IBM Intellectual Property Department in your country or send inquiries, in writing, to: Intellectual Property Licensing Legal and Intellectual Property Law IBM Japan, Ltd , Nihonbashi-Hakozakicho, Chuo-ku Tokyo , Japan INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-ibm websites are provided for convenience only and do not in any manner serve as an endorsement of those Copyright IBM Corp. 2012,

92 websites. The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk. IBM may use or distribute any of the information you provide in any way it believes appropriate without incurring any obligation to you. Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact: IBM Director of Licensing IBM Corporation North Castle Drive, MD-NC119 Armonk, NY US Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee. The licensed program described in this document and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us. The performance data discussed herein is presented as derived under specific operating conditions. Actual results may vary. Information concerning non-ibm products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-ibm products. Questions on the capabilities of non-ibm products should be addressed to the suppliers of those products. Statements regarding IBM's future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only. All IBM prices shown are IBM's suggested retail prices, are current and are subject to change without notice. Dealer prices may vary. This information is for planning purposes only. The information herein is subject to change before the products described become available. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application 70 Storwize V3700: Quick Installation Guide

93 programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. The sample programs are provided "AS IS", without warranty of any kind. IBM shall not be liable for any damages arising out of your use of the sample programs. If you are viewing this information softcopy, the photographs and color illustrations may not appear. Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the web at Copyright and trademark information at Homologation statement Electronic emission notices Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates. Linux and the Linux logo is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other product and service names might be trademarks of IBM or other companies. This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks. Further certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions. This section contains the electronic emission notices or statements for the United States and other countries. Federal Communications Commission (FCC) statement This explains the Federal Communications Commission's (FCC s) statement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, might cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Notices 71

94 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors, or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device might not cause harmful interference, and (2) this device must accept any interference received, including interference that might cause undesired operation. Industry Canada compliance statement This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conform à la norme NMB-003 du Canada. Australia and New Zealand Class A Statement Attention: This is a Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures. European Union Electromagnetic Compatibility Directive This product is in conformity with the protection requirements of European Union (EU) Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-ibm option cards. Attention: This is an EN Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures. Responsible Manufacturer: International Business Machines Corp. New Orchard Road Armonk, New York European community contact: IBM Deutschland GmbH Technical Regulations, Department M372 IBM-Allee 1, Ehningen, Germany Tele: +49 (0) or +49 (0) halloibm@de.ibm.com Germany Electromagnetic Compatibility Directive Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen Verträglichkeit 72 Storwize V3700: Quick Installation Guide

95 Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung der IBM gesteckt/eingebaut werden. EN Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden: Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funk-Störungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Mabnahmen zu ergreifen und dafür aufzukommen. Deutschland: Einhaltung des Gesetzes über die elektromagnetische Verträglichkeit von Geräten Dieses Produkt entspricht dem Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG). Dies ist die Umsetzung der EU-Richtlinie 2004/108/EG in der Bundesrepublik Deutschland. Zulassungsbescheinigung laut dem Deutschen Gesetz über die elektromagnetische Verträglichkeit von Geräten (EMVG) (bzw. der EMC EG Richtlinie 2004/108/EG) für Geräte der Klasse A Dieses Gerät ist berechtigt, in übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die Einhaltung der EMV Vorschriften ist der Hersteller: International Business Machines Corp. New Orchard Road Armonk,New York Tel: Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Regulations, Abteilung M372 IBM-Allee 1, Ehningen, Germany Tele: +49 (0) or +49 (0) halloibm@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN und EN Klasse A. People's Republic of China Class A Statement Notices 73

96 Taiwan Class A compliance statement Taiwan Contact Information This topic contains the product service contact information for Taiwan. IBM Taiwan Product Service Contact Information: IBM Taiwan Corporation 3F, No 7, Song Ren Rd., Taipei Taiwan Tel: f2c00790 Japan VCCI Council Class A statement This explains the Japan Voluntary Control Council for Interference (VCCI) statement. Japan Electronics and Information Technology Industries Association Statement This statement explains the Japan JIS C product wattage compliance. See Knowledge Center 74 Storwize V3700: Quick Installation Guide

97 This statement explains the Japan Electronics and Information Technology Industries Association (JEITA) statement for products less than or equal to 20 A per phase. This statement explains the JEITA statement for products greater than 20 A, single phase. This statement explains the JEITA statement for products greater than 20 A per phase, three-phase. Korean Communications Commission Class A Statement This explains the Korean Communications Commission (KCC) statement. Russia Electromagnetic Interference Class A Statement This statement explains the Russia Electromagnetic Interference (EMI) statement. rusemi European Contact Information This topic contains the product service contact information for Europe. Notices 75

IBM Storwize V5000 Gen2. Quick Installation Guide IBM GC

IBM Storwize V5000 Gen2. Quick Installation Guide IBM GC IBM Storwize V5000 Gen2 Quick Installation Guide IBM GC27-8581-02 Note Before using this information and the product it supports, read the following information: v The general information in Notices on

More information

IBM Storwize V5000. Quick Installation Guide IBM GI

IBM Storwize V5000. Quick Installation Guide IBM GI IBM Storwize V5000 Quick Installation Guide IBM GI13-2861-05 Note Before using this information and the product it supports, read the following information: v The general information in Notices on page

More information

IBM Storwize V3500. Quick Installation Guide IBM GC

IBM Storwize V3500. Quick Installation Guide IBM GC IBM Storwize V3500 Quick Installation Guide IBM GC27-4218-08 Note Before using this information and the product it supports, read the following information: v The general information in Notices on page

More information

IBM Storwize V7000. Troubleshooting, Recovery, and Maintenance Guide IBM GC

IBM Storwize V7000. Troubleshooting, Recovery, and Maintenance Guide IBM GC IBM Storwize V7000 Troubleshooting, Recovery, and Maintenance Guide IBM GC27-2291-11 Note Before using this information and the product it supports, read the following information: v The general information

More information

Quick Installation Guide

Quick Installation Guide IBM Storwize V7000 Quick Installation Guide GC27-2290-04 Note Before using this information and the product it supports, read the general information in Notices on page 35, the information in the Safety

More information

IBM Storwize V7000. Troubleshooting, Recovery, and Maintenance Guide IBM GC

IBM Storwize V7000. Troubleshooting, Recovery, and Maintenance Guide IBM GC IBM Storwize V7000 Troubleshooting, Recovery, and Maintenance Guide IBM GC27-2291-15 Note Before using this information and the product it supports, read the following information: v The general information

More information

Quick Installation Guide

Quick Installation Guide IBM Storwize V7000 Gen2 Quick Installation Guide GC27-6500-03 Note Before using this information and the product it supports, read the following information: The general information in Notices on page

More information

Troubleshooting Guide

Troubleshooting Guide IBM System Storage SAN Volume Controller Troubleshooting Guide GC27-2284-04 Note Before using this information and the product it supports, read the information in Notices on page 319. This edition applies

More information

Quick Installation Guide

Quick Installation Guide IBM Storwize V5000 Quick Installation Guide GI3-286-00 Note Before using this information and the product it supports, read the general information in Notices on page 37, the information in the Safety

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Quick Installation Guide

Quick Installation Guide IBM Storwize V7000 Quick Installation Guide Version 6.1.0 GC27-2290-00 IBM Storwize V7000 Quick Installation Guide Version 6.1.0 GC27-2290-00 Note Before using this information and the product it supports,

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions For System Storage EXP2512 and EXP2524 Express Storage Enclosures Use the instructions in this document to install an IBM System Storage EXP2512 Express Storage Enclosure

More information

EXN4000 Storage Expansion Unit Installation and Setup Instructions

EXN4000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 IBM System Storage EXN4000 Storage Expansion Unit Installation and Setup Instructions GC27-2079-02 Notices

More information

Troubleshooting, Recovery, and Maintenance Guide

Troubleshooting, Recovery, and Maintenance Guide IBM Storwize V7000 Troubleshooting, Recoery, and Maintenance Guide GC27-2291-10 Note Before using this information and the product it supports, read the following information: The general information in

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

System Storage EXP3000 Rack Installation Instructions

System Storage EXP3000 Rack Installation Instructions System Storage EXP3000 Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When you install the IBM System Storage EXP3000 in a

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two

More information

N3240 Installation and Setup Instructions

N3240 Installation and Setup Instructions IBM System Storage N3240 Installation and Setup Instructions Covering the N3240 model GA32-2203-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

Quick Installation Guide

Quick Installation Guide IBM Storwize V7000 Quick Installation Guide GC27-2290-05 Note Before using this information and the product it supports, read the general information in Notices on page 35, the information in the Safety

More information

System Storage DS3950 Quick Start Guide

System Storage DS3950 Quick Start Guide System Storage DS3950 Quick Start Guide This Quick Start Guide describes the basic procedure for installing, cabling, and configuring the IBM System Storage DS3950 storage subsystem (Machine Types 1814-94H

More information

IBM Storwize V7000. Troubleshooting, Recovery, and Maintenance Guide IBM GC

IBM Storwize V7000. Troubleshooting, Recovery, and Maintenance Guide IBM GC IBM Storwize V7000 Troubleshooting, Recoery, and Maintenance Guide IBM GC27-2291-11 Note Before using this information and the product it supports, read the following information: The general information

More information

To connect the AC adapter:

To connect the AC adapter: Replacing the AC Adapter Replacing the AC Adapter 3 Plug the power cord into a wall outlet. The power indicator turns on. To connect the AC adapter: Connect the power cord to the AC adapter. Power indicator

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

Preparing to Install the VG248

Preparing to Install the VG248 CHAPTER 2 To ensure normal system operation, plan your site configuration and prepare your site before installation. Before installing the VG248, review these sections: Preparing the Installation Site,

More information

Installation Roadmap Guide

Installation Roadmap Guide IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide for ProtecTIER 3. GA3-090-0 IBM System Storage TS7650 ProtecTIER Deduplication Appliance Installation Roadmap Guide

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

N3150 Installation and Setup Instructions

N3150 Installation and Setup Instructions IBM System Storage N350 Installation and Setup Instructions Covering the N350 model GC27-426-0 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-000

More information

IBM FlashSystem V840. Installation Guide GI

IBM FlashSystem V840. Installation Guide GI IBM FlashSystem V840 Installation Guide GI13-2873-00 Note Before using this information and the product it supports, read the general information in Notices on page 63, the information in the Safety and

More information

N3220 Installation and Setup Instructions

N3220 Installation and Setup Instructions IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32-2202-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

Troubleshooting, Recovery, and Maintenance Guide

Troubleshooting, Recovery, and Maintenance Guide IBM Storwize V7000 Troubleshooting, Recoery, and Maintenance Guide GC27-2291-06 Note Before using this information and the product it supports, read the general information in Notices on page 205, the

More information

InnoMedia Business VoIP ATA Models

InnoMedia Business VoIP ATA Models InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment

More information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions HP UPS R/T3000 ERM Installation Instructions Overview The ERM consists of two battery packs in a 2U chassis. The ERM connects directly to a UPS R/T3000 or to another ERM. Up to two ERM units can be connected.

More information

IBM Systems. Quick start guide for IBM System p5 505 ( )

IBM Systems. Quick start guide for IBM System p5 505 ( ) IBM Systems Quick start guide for IBM System p5 505 (9115-505) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis 5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital

More information

Troubleshooting Guide

Troubleshooting Guide IBM System Storage SAN Volume Controller Version 6.4.0 Troubleshooting Guide GC27-2284-03 Note Before using this information and the product it supports, read the information in Notices on page 267. This

More information

IBM Storage Appliance 2421 Model AP1 Version 1 Release 1. Planning, Installation, and Maintenance Guide IBM SC

IBM Storage Appliance 2421 Model AP1 Version 1 Release 1. Planning, Installation, and Maintenance Guide IBM SC IBM Storage Appliance 2421 Model AP1 Version 1 Release 1 Planning, Installation, and Maintenance Guide IBM SC27-8520-02 Note Before using this information and the product it supports, read the information

More information

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

IBM FlashSystem 840. Installation Guide GI

IBM FlashSystem 840. Installation Guide GI IBM FlashSystem 840 Installation Guide GI13-2871-01 Note Before using this information and the product it supports, read the following information: The general information in Notices on page 51 The information

More information

IBM Storwize V7000 Expansion Enclosure Installation Guide

IBM Storwize V7000 Expansion Enclosure Installation Guide IBM Storwize V7000 Expansion Enclosure Installation Guide IBM Storwize V7000 Expansion Enclosure Installation Guide GC27-4234-02 Note Before using this information and the product it supports, read the

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Power Systems. System processor assembly

Power Systems. System processor assembly Power Systems System processor assembly Power Systems System processor assembly Note Before using this information and the product it supports, read the information in Notices, on page 75, Safety notices

More information

Preparing to Install the Cisco AS5350XM Universal Gateway

Preparing to Install the Cisco AS5350XM Universal Gateway CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following

More information

Voltage regulators for the E ESCALA Power7 REFERENCE 86 A1 17FF 07

Voltage regulators for the E ESCALA Power7 REFERENCE 86 A1 17FF 07 Voltage regulators for the E5-700 ESCALA Power7 REFERENCE 86 A1 17FF 07 ESCALA Models Reference The ESCALA Power7 publications concern the following models: Bull Escala E1-700 / E3-700 Bull Escala E1-705

More information

N6000 Series Hardware and Service Guide

N6000 Series Hardware and Service Guide IBM System Storage N6000 Series Hardware and Service Guide Covering the N6040, N6060 and N6070 models GC53-1142-07 IBM System Storage N6000 Series Hardware and Service Guide Covering the N6040, N6060

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Installation Roadmap Guide

Installation Roadmap Guide IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide forthets7650g(3958dd4-gateway) GC53-1154-09 IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide forthets7650g(3958dd4-gateway)

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual

ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual ThinkStation P320 Tiny User Guide and Hardware Maintenance Manual Machine Types (MTs): 30C1 (Energy Star), 30C2 (Energy Star), and 30C3 (Energy Star) Note: Before using this information and the product

More information

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller. IBM System Storage DS4800 Controller Cache Upgrade Kit Instructions Attention: IBM has renamed some FAStT family products. FAStT EXP100 has been renamed DS4000 EXP100, FAStT EXP700 has been renamed DS4000

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions 4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

Wall-Mounting your HP TouchSmart. User Guide

Wall-Mounting your HP TouchSmart. User Guide Wall-Mounting your HP TouchSmart User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein

More information

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

Model 2145-CG8 Hardware Installation Guide

Model 2145-CG8 Hardware Installation Guide IBM System Storage SAN Volume Controller Model 2145-CG8 Hardware Installation Guide GC27-3923-04 Note Before using this information and the product it supports, read the general information in Notices

More information

1 Getting Started Installing & Configuring

1 Getting Started Installing & Configuring Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760 and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Drive Trays

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

Quick start guide for i5 520 ( or )

Quick start guide for i5 520 ( or ) Quick start guide for i5 520 (9405-520 or 9406-520) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up a standard

More information

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211 Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215,

More information

Customer Upgrade Procedure

Customer Upgrade Procedure Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace

More information

EXN3000 Storage Expansion Unit Installation and Setup Instructions

EXN3000 Storage Expansion Unit Installation and Setup Instructions IBM System Storage EXN3000 Storage Expansion Unit Installation and Setup Instructions G52-1345-03 Notices Mail comments to: IBM orporation Attention epartment GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i Assembly Guide Model 133i Radio Frequency Interference Notice (USA) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules,

More information

Installing and Configuring the Hardware Management Console. ESCALA Power7 REFERENCE 86 A1 28FF 06

Installing and Configuring the Hardware Management Console. ESCALA Power7 REFERENCE 86 A1 28FF 06 Installing and Configuring the Hardware Management Console ESCALA Power7 REFERENCE 86 A1 28FF 06 Installing and Configuring the Hardware Management Console The ESCALA Power7 publications concern the following

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed

More information

Installing the 5886 disk drive enclosure

Installing the 5886 disk drive enclosure Power Systems Installing the 5886 disk drive enclosure GI11-2910-08 Power Systems Installing the 5886 disk drive enclosure GI11-2910-08 Note Before using this information and the product it supports,

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information

Model 2145-CG8 Hardware Installation Guide

Model 2145-CG8 Hardware Installation Guide IBM System Storage SAN Volume Controller Model 2145-CG8 Hardware Installation Guide GC27-3923-03 Note Before using this information and the product it supports, read the general information in Notices

More information

Installing the Cisco SFS 3504 Server Switch

Installing the Cisco SFS 3504 Server Switch CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see

More information

N3150, N3220, and N3240 Hardware and Service Guide

N3150, N3220, and N3240 Hardware and Service Guide IBM System Storage N3150, N3220, and N3240 Hardware and Service Guide CoveringtheN3150,N3220,andN3240models SC27-4214-04 Note: Before using this information and the product it supports, be sure to read

More information

Upgrading and Servicing Guide

Upgrading and Servicing Guide Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

MX480 3D Universal Edge Router

MX480 3D Universal Edge Router MX480 3D Universal Edge Router Hardware Guide Published: 2013-08-29 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net This product includes

More information

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware. Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760, E5560, and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Hardware

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information