Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.
|
|
- Amberly Short
- 5 years ago
- Views:
Transcription
1 Page 1 of 5 Model 282 Total Interface Isolation Module Reference Manual Rev. A Print General Description Table of Contents 2.0 Specifications 2.1 Interface 2.2 Connectors 2.3 Isolation 2.4 Data Rate 2.5 Power 2.6 Size 2.7 Environment 3.0 Operation 4.0 Connector Pin Assignment 5.0 Power 6.0 Help Appendix A.- Power Plug Connection Warranty 1.0 General Description The Model 282 Total Interface Isolation Module provides for a complete full-duplex electrical isolation between two RS-232 devices (including all asynchronous control signals). This isolation is an important consideration if the systems to be connected use different ower sources, have noisy signals, or must operate at different ground potentials.
2 Page 2 of Specifications 2.1 Interface Conforms to EIA RS-232 and CCITT V.24 specifications. Pin 2, Transmit Data; Pin 3, Receive Data; Pin 4, Request to Send; Pin 5, Clear to Send; Pin 6, Data Set Ready; Pin 7, Signal Ground; Pin 8, Data Carrier Detect; Pin 20, Data Terminal Ready; and Pin 22 Ring Indicator. 2.2 Connectors DTE = DB-25F DCE = DB-25M 2.3 Isolation 1000V 2.4 Data Rate 0 to 64 kb 2.5 Power 110V AC 60Hz (220V 50Hz optional) (-48V DC optional) 2.6 Size 2.25" W x 6.75" L x 1" H (57mm W x 171 mm L x 25mm H) 2.7 Environment 0 to 50C, 5% to 95% RH (no condensation)
3 Page 3 of Operation The male DB-25 connector is a DCE port and will connect to the DTE device, such as a terminal or PC. The DB-25 female connector is a DTE port and is connected to a DCE device, such as a dial-up modem. The direction of each signal is shown in Figure Connector Pin Assignment Pin EIA CCITT Name 2 BA 103 Transmit Data 3 BB 104 Receive Data 4 CA 105 Request to Send 5 CB 106 Clear to Send 6 CC 107 Data Set Ready 7 AB 102 Signal Ground 8 CF 109 Data Carrier Detect 20 CD Data Terminal Ready 22 CE 125 Ring Indicator
4 Page 4 of Power The Model 282 has a built-in isolated DC-to-DC converter. Low voltage AC is supplied by a small wall-mounted transformer. This AC voltage is converted to DC voltage which is used to power the DCE side of the Model 282. The DC voltage is also applied to the isolated DCto-DC converter, which is also used to power the DTE side of the Model 282. Alternatively, the Model 282 can be ordered as the Model which includes a _48 VDC Converter assembly with the Model 282 housings. The user simply connects the supplied cord to the _48 VDC supply. 6.0 Help If you require assistance, please call Telebyte Customer Service at (631) , fax us at (631) or us at support@telebyteusa.com. Appendix A. Power Plug Connection
5 Page 5 of 5 Warranty TELEBYTE warrants the equipment to be free from defects in material and workmanship under normal and proper use and in its unmodified condition, for 12 months, starting on the date it is delivered for use. TELEBYTE's sole obligation under this warranty shall be to furnish parts and labor for the repair or replacement of products found by TELEBYTE to be defective in material or workmanship during the warranty period. Warranty repairs will be performed at the point of manufacture. Equipment approved for return for warranty service shall be returned F.O.B. TELEBYTE factory and will be redelivered by TELEBYTE freight prepaid, except for non-continental U.S.A. locations. Non-continental deliveries will be sent COD freight plus import/export charges. The above warranty is in lieu of all other warranties, expressed or implied, statutory or otherwise, including any implied warranty of merchantability or fitness for a particular purpose. TELEBYTE shall not be liable for any damages sustained by reseller or any other party arising from or relating to any equipment failure, including, but not limited to consequential damages nor shall TELEBYTE have any liability for delays in replacement or repair of equipment. Out of warranty equipment may be returned to the Greenlawn, NY customer service facility prepaid as described above. Return shipping charges will be billed to the customer. The repaired unit will have a 90-day warranty. In those cases where "NO TROUBLE" is found, a reduced charge will be billed to cover handling, testing and packaging. Whether in or out of warranty, a Return Material Authorization (RMA) number is necessary and can be obtained by calling (631) or 1-(800) , by faxing (631) /7060 or by ing us at support@telebyteusa.com. You can also visit us on the web at Reference the RMA number on the outside container. Document No /Rev. A Distributed by: L-com CONNECTIVITY PRODUCTS 45 Beechwood Drive North Andover, MA sales@l-com.com Fax: Toll Free:
600 SERIES. Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation. Reference Manual. Rev A. Version 2.6.0
Results You Can Count On Reference Manual 600 SERIES Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation Rev A Version 2.6.0 Date of Publication: 03/05/2019 Customer Care Warranty
More informationUSER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter
USER MANUAL MODEL 011 High Speed Asynchronous to Synchronous Converter Part# 07M011-A Doc# 0601UA Revised 03/16/94 SALES ICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationUSER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2014 Interface Powered RS-530 to V.35 Converter An ISO-9001 Certified Company Part #07M2014-C Doc. #070011UC Revised 4/22/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
More informationPRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...
IR-510 Bench 2012 Infrared Industries, Inc. 25590 Seaboard Lane Hayward, CA 94545 Toll-free phone 800.344.0321 Phone 510.782.8100 Fax 510.782.8101 www.infraredindustries.com Table of Contents I. PRODUCT
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More information6001TA Terminal Adapter Installation Instructions
6001TA Terminal Adapter Installation Instructions The Model 6001 Terminal Adapter allows a Tone Commander 6210 or 6220 ISDN telephone to be controlled by a TAPI-compliant Windows computer application program.
More informationEnhanced Mini-Chansim Model VCS-232
Enhanced Mini-Chansim Model VCS-232 Operations Manual ViaSat Inc. 6155 El Camino Real Carlsbad, CA 92009 http://www.viasat.com SAFETY WARNING Always observe standard safety precautions during installation,
More informationUSER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION
More informationUSER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters
USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0
More informationUSER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators
USER MANUAL MODELS 1205 and 1205/34 Synchronous V.35 Modem Eliminators An ISO-9001 Certified Company Part #07M1205-D Doc #049021U, Rev. E Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
More informationSC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL
SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL REVISION: 7/02 COPYRIGHT (c) 1998-2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The SC532A 9-PIN PERIPHERAL
More informationDigital Lighting Systems, Inc.
Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical
More informationCHAPTER 2 CHAPTER 1 INTRODUCTION
CHAPTER 1 INTRODUCTION The RS232 to RS485 photo isolator provides a RS232 signals to RS485 signals conversion features, which are used to expand long haul communication distance via multi-drop communication
More informationData Broadcast Switch
Data Broadcast TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS... SECTION - INTERFACE SIGNALS AND CABLING...
More informationUSER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter
USER MANUAL MODEL 2030 Bidirectional (IEEE-1284) Line Driver/Converter An ISO-9001 Certified Company Part # 07M2030-B Doc. #102121U, Rev. C Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationSC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL
SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL REVISION: 1/93 COPYRIGHT (c) 1987, 1993 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The SC32A OPTICALLY ISOLATED RS232 INTERFACE is warranted
More informationUser Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B
User Guide DMXSM-H18 Splitter DMXSM-H81 Merger Document Release Aug. 2008 Revision B Warranty Leviton Manufacturing Co Inc. warrants this device to be free of material and workmanship defects for a period
More informationSerial Converters WTS 1201/-CP. RS-232 to IEEE b Wireless Converter with WEP Encryption, and External Antenna
Serial Converters WTS 1201/-CP RS-232 to IEEE 802.11b Wireless Converter with WEP Encryption, and External Antenna WTS 1201: External Power Supply (Included) WTS 1201-CP: Powered through serial cable Quick
More informationProliphix EPA-60 Installation Guide
Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY
More informationSC532 9-Pin Peripheral to RS232 Interface
SC532 9-Pin Peripheral to RS232 Interface User Guide Issued 3.2.93 Copyright 1993 Campbell Scientific, Inc. Copied under licence by Campbell Scientific Ltd. Guarantee This equipment is guaranteed against
More informationVCMDM MODEM INSTALLATION INSTRUCTIONS
Issue 1 www.class-connection.com VCMDM MODEM INSTALLATION INSTRUCTIONS The VCMDM Modem Package allows the user to program the Class Connection TM or VC-24 System from an off-site location. This document
More informationACLD Channel Opto-isolated Digital Input Board
ACLD-9182 16 Channel Opto-isolated Digital Input Board @ Copyright 1996 All Rights Reserved. Manual edition 01, January 1996 The information in this document is subject to change without prior notice in
More informationDIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL
DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL REVISED: 8/12/13 DGH CORPORATION PO BOX 5638 MANCHESTER, NH 03108 TELEPHONE: 603-622-0452 FAX: 603-622-0487 WEB: www.dghcorp.com The information
More informationDigital Lighting Systems, Inc.
, Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual
More informationD56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7
D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 SECTION 4 - FRONT PANEL INDICATORS...8 SECTION 5 - INTERFACE SIGNALS...9 SECTION 6 -
More informationXC300 VDSL Network Extender Owners Manual
XC300 VDSL Network Extender Owners Manual Warranty GDI Communications LLC warrants to the original consumer purchaser that each of its hardware products, and all components thereof, will be free from defects
More informationDigital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module
, Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION
More informationHydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual
HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual Document No: WD102681-1 Document Revision Date: April, 2011 HydroLynx Systems, Inc. Model 50386D Decoder Receiving and Unpacking Carefully
More information62532 (EN649) Ethernet Adapter
62532 (EN649) Ethernet Adapter INSTALLATION AND OPERATING INSTRUCTIONS For sales and Service in North America contact: ESD Systems.com www.esdsystems.com sales@esdsystems.com Phone: 508-485-7390 Fax: 508-480-0257
More informationIntegrator Pro User Manual
Integrator Pro User Manual Mesa Labs Commitment As a manufacturer of critical equipment, quality is the highest priority in our manufacturing process. Mesa Labs commits to providing creative, innovative
More information62533 Ethernet Adapter
62533 Ethernet Adapter INSTALLATION AND OPERATING INSTRUCTIONS For sales and Service in North America contact: ESD Systems.com www.esdsystems.com sales@esdsystems.com Phone: 508-485-7390 Fax: 508-480-0257
More informationSTATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,
More informationV-9908 MESSAGE/PAGE PANEL
Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides
More informationUSB Ranger 422 User Guide
USB Ranger 422 User Guide Featuring ExtremeUSB Technology USB Ranger 422 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to Part Numbers:
More informationUSER MANUAL MODEL 515 DB-15 Surge Protector
USER MANUAL MODEL 515 DB-15 Surge Protector Part# 07M515-A Doc# 074220U, Rev. B Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY Patton Electronics
More informationMulti-Channel RS-232 Current Loop Interface Converter (CLIC)
DECEMBER 1996 CL204A CL208A CL212A CL216A Multi-Channel RS-232 Current Loop Interface Converter (CLIC) CLIC 1/2A,SLO BLO,115VAC 1/4,SLO BLO,230VAC CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.:
More informationMODEL No. SW1X8 RS422 SWITCHER
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com MODEL No. SW1X8 RS422 SWITCHER User Manual TABLE OF CONTENTS I. REVISION HISTORY... 2 II. INTRODUCTION...
More informationWARRANTY & LIMITATION OF LIABILITY
MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)
More informationTC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual
Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee
More informationINSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N
INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N IF FOR SOME REASON YOU HAVE TO RETURN THIS ITEM TO THE FACTORY FOR ANY SERVICE OR REPAIR, YOU MUST CONTACT CUSTOMER SERVICE FOR AN RMA NUMBER AT (585)
More information1875 Smart Calibrator. Instruction Manual
THORNTON Leading Pure Water Analytics Part No. 84386 1875 Smart Calibrator for 770MAX Multiparameter Analyzer/Transmitter Instruction Manual INTRODUCTION This manual covers operation of the Mettler- Toledo
More informationWARRANTY & LIMITATION OF LIABILITY
MUX-485 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)
More informationUSER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1052 idsl Modem with RS-232 Interface An ISO-9001 Certified Company Part# 07M1052-B Doc# 058061UB Revised 5/24/02 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 TABLE OF
More informationV CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER
Issue 1 V-9983 2 CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V-9985 4 CHANNEL MODULAR PRE-AMP/MIXER INTRODUCTION These instructions contain the specifications and guidelines necessary to install,
More information500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System
Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2
More informationVIP-812A DUAL NETWORKED STATION PORT
ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS
More informationDigital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack
Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems,
More informationOPERATOR S MANUAL FPD 50 WATT POWER SUPPLY. Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input
OPERATOR S MANUAL FPD 50 WATT POWER SUPPLY Flat Pack Single Output DC to DC Converter 50 Watt Output 24 Vdc Nominal Input KEPCO INC. An ISO 9001 Company. MODEL FPD 50W-24V POWER SUPPLY IMPORTANT NOTES:
More informationEthernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01
Anybus X-gateway Ethernet to J1939 Installation Guide AB7665 Part no. SP0863 Rev. 1.01 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 +
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationEAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06
Instruction Manual EAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06 Emergency Alert Systems CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville
More informationAn ISO-9001 Certified Company
USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationVE8014A/VE8014AR QUAD NETWORKED STATION PORT
ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.
More informationCard Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.
Installation And Operation BASIC A/B SWITCHES K-AB-D25 K-AB-M34 SCOPE OF THIS DOCUMENT This document covers the following models: K-AB-D25 K-AB-D25-R K-AB-M34 K-AB-M34-R For the purposes of clarity, all
More informationTB-24P/24R/16P8R. Relay Outputs or Isolated Inputs Terminal Board Series
TB24P/24R/16P8R Relay Outputs or Isolated Inputs Terminal Board Series @Copyright 1995~1998 ADLink Technology Inc. All Rights Reserved. Manual first edition: 15, August 1995 Manual second edition: 01,
More informationASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7
ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...10
More informationex tend it User Manual L-com CONNECTIVITY
ex tend it Firewire Extender Extends Firewire up to 1640 feet User Manual Distributed by: L-com CONNECTIVITY PRODUCTS 45 Beechwood Drive North Andover, MA 01845 www.l-com.com E-mail: sales@l-com.com Fax:
More informationPRO-DVI-CAT. DVI over Single CAT5 Extender. User Manual. Made in Taiwan
PRO-DVI-CAT DVI over Single CAT5 Extender User Manual Made in Taiwan rev.1008 103 Quality Circle, Suite 210 Huntsville, Alabama 35806 Tel: (256) 726-9222 Fax: (256) 726-9268 Email: service@pesa.com Safety
More informationUSER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationM82xxD Fiber Optic RS-232 MicroModem Technical Manual
M82xxD Fiber Optic RS-232 MicroModem Technical Manual Revision C August 2016 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY
More informationMTS-2000 USER S MANUAL
MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this
More informationUser Manual. Spectrum Pro
80140502-001 User Manual Spectrum Pro PCI PTS 4.X Hybrid Insert Reader RS232 Interface 80140502-001 Rev 51 3/10/2015 International Technologies & Systems Corporation 10721 Walker Street, Cypress, CA 90630-4720;
More informationThe EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option
KB/HB-Series INSTALLATION INSTRUCTIONS EB7-4W Module Installation Clear-Com s EB7-4W 4-Wire Option module can be added to the KB-702, KB- 702GM, KB-701, and HB-702 products. This option allows the speaker
More informationANC Series RS-422 Serial Communications Adapter
Rev. B $ 5.00 ANC - 6000 Series RS-422 Serial Communications Adapter Antona Corporation, Los Angeles, CA Antona Corporation (818)783-4299 FAX (818)783-4216 1 Antona Corporation Copyright Copyright (c)
More informationUSER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
More informationNT1B-300 Rack Installation Instructions
The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies
More informationUSER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem
USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem An ISO-9001 Certified Company Part #07M1003-B Doc. #050021UB Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL
More informationCC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK
FN:CC186M2.DOC CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK DESCRIPTION The CC186 is a single sided clock with six, 1.8 inch high digits. The CC186/2 is a double sided clock with six, 1.8 inch high digits
More informationF2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual
F2238A and F2245A Fiber-Optic EIA-530/MIL-STD-188-114 Modem Technical Manual Revision C October 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com PROPRIETARY DATA All data
More informationUSER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 503P & 503PC Parallel Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M503P-C Doc# 074201U Rev. D Revised 1/21/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationChannel Switch CS. General Operating, Maintenance and Installation Manual
Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September
More informationMulti-Port Controller
Multi-Port Controller TABLE OF CONTENTS SECTION 1 DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...10
More informationUser Guide. Control Box. RoscoLED TM.
RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260
More informationIMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100
IMS-9000 Intelligent Modem Switch USER S MANUAL Document Part #: RDC-HDWIMS9K100 2000 Delphi Display Systems, INC. All rights reserved. Delphi Display Systems, INC. (Delphi) reserves the right to revise
More informationMODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL
10623 Roselle Street, San Diego, CA 92121 (858) 550-9559 FAX (858) 550-7322 contactus@accesio.com www.accesio.com MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL FILE: MUSB-DA12-8E.B1h
More informationF280XD Fiber-Optic RS-232 Modem Technical Manual
F280XD Fiber-Optic RS-232 Modem Technical Manual Revision B August 2012 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY DATA
More informationNT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack
The NT1-220 Rack is designed to be used in conjunction with Tone Commander NT1U-220TC ISDN Network Terminations. A maximum of twelve NT1 units can be used in each rack. NT1-220 Rack Installation Instructions
More informationPowered Roller Controller for DeviceNet
PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered
More informationV-9939B MICROPHONE ADAPTER
Issue 10 INTRODUCTION These instructions provide identification, installation, connection, operation and maintenance information for the Microphone Adapter. The is a Microphone Adapter designed to be used
More informationEco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features
Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use General and New Features The OS-6 is an industrial grade Ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease
More informationSPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4
SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - CONTROLS AND INDICATORS...6 SECTION - EXECUTIVE PORT...9 SECTION 6 - INTERFACE SIGNALS
More informationES-600 Ozone Controller Operation Manual
ES-600 Ozone Controller Operation Manual Questions about your product? Find answers here: Web: www.ozonesolutions.com/es-600 Phone: 712-439-6880 Ozone Solutions OZONE CONTROLLER Model ES-600 Instructions
More informationINSTRUCTION MANUAL. AquiStar GDL. Dissolved Oxygen Datalogger
INSTRUCTION MANUAL AquiStar GDL Dissolved Oxygen Datalogger Table of Contents 1 Introduction... 3 What is a GDL?... 3 Initial Inspection and Handling... 3 Do s and Don ts... 3 Getting Started... 4 GDL
More informationConitel ASYNC Adapter
Conitel ASYNC Adapter TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS... SECTION - INSTALLATION...6 SECTION - CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...11
More informationUSER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODELS 2156 & 2157 CopperLink Ethernet Extenders An ISO-9001Certified Company Part# 07M2156_2157 Doc# 032131U Rev. A Revised 2/4/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
More informationMPP200 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationVIP-804 QUAD ENHANCED NETWORK AUDIO PORT
ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to
More informationTALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD
Issue 8 TALKBACK INTERCOM SYSTEM V-2926 OPTION BOARD The V-2926 Option Board is an add-on feature for the V-2924A Expandable Zone Talkback Intercom System. The addition of this board provides the following
More informationMD9 MULTIDROP INTERFACE INSTRUCTION MANUAL
MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by
More informationRS422 PORT SWITCHER REMOTE CONTROL PANEL
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. SW32PS-RCP RS422 PORT SWITCHER REMOTE CONTROL PANEL User Manual Rev 1.01 TABLE OF
More informationPSI DITHERLESS BIAS CONTROLLER USER GUIDE
PSI-0404-11 DITHERLESS BIAS CONTROLLER USER GUIDE Rev D Photonic Systems, Inc. Tel: 978-670-4990 900 Middlesex Turnpike Fax: 978-670-2510 Building #5 www.photonicsinc.com Billerica, MA 01821 1 DOCUMENT
More informationZM24x Quick-Connect Industrial Modem. User s Manual
ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of
More informationDATA CONNECT ENTERPRISE
DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. C Copyright 2009 Data Connect Enterprise. All Rights Reserved. Web site: www.data-connect.com The products
More informationCMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1
CMR-8500 Quick Start Guide CMR-8500 DVB IP Encapsulator Part Number MN-CMR68500-QSG REV. 1 Copyright Comtech EF Data, 2008. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street,
More informationOPERATIONS MANUAL PCM-DOC
OPERATIONS MANUAL PCM-DOC NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual
More informationUser s Guide. POWERVAR Single Phase Power Conditioners
POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant
More informationRT-ANA. User Manual. Analogue Interface for the RT3000. Confidently. Accurately.
RT-ANA Analogue Interface for the RT3000 User Manual Confidently. Accurately. RT-ANA User Manual Table of Contents Introduction 4 Scope of Delivery 5 Specification 6 Warranty 7 Functional Overview 8 Configuration
More informationINSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE
INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationModel No. ST200-S-RCP
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com Model No. ST200-S-RCP DUAL FUNCTION RS422 REMOTE CONTROL PORT SWITCHER AND VTR CONTROLLER User
More information