6R MATRIX Pre-Defined. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

Size: px
Start display at page:

Download "6R MATRIX Pre-Defined. Modular Relays. rms. Auxiliary, Trip & Supervision Relays"

Transcription

1 Pre-Defined Modular Relays Auxiliary, Trip & Supervision Relays Rugged modular construction Rack or flush mounting Range of function types Draw out module, & 20 contact versions Operating & reset coils are available for 24, 32, 48, 1, 12, 220, 240 or 20 Volts High visibility electro-mechanical flag indication Made in Australia 6R Matrix Pre Defined Commom_M 18/06/2018 rms

2 Introduction Description The effect of a fault on a power system is dependent on the speed with which the fault can be detected & isolated. Modern protection schemes incorporate ever increasing functionality through the application of digital techniques to protection relay technology. The requirement for highly reliable tripping & control relay elements does however remain & often constitutes a significant cost & space requirement for protection panel designs. The system fulfils this need by providing a compact, flexible & cost effective solution. The range was developed to provide design engineers with a modular system of auxiliary relays to meet specific system configurations. The versions described in this publication have pre-defined functional & contact configurations to offer the following advantages: Simpler to specify & order; Lower cost due to model rationalization; Direct cross reference to other manufacturers models; Standardized wiring details. Cross Reference List Alstom Reyrolle RMS MVAA AR 6RA MVAJ TR 6RJ MVAX XR 6RX Size Size 4M6-S 2 rms

3 Pre-defined Relay Versions High Speed Tripping Relays RMS Alstom Reyrolle Functional Description Contacts Case 6RJ11- MVAJ11, MVAJ01 TR112 Low burden high speed trip relay Self reset contacts 6RJ11- MVAJ11, MVAJ1 TR112 Hand reset flag 6RJ12-6RJ12- MVAJ16, MVAJ02 MVAJ16, MVAJ2 - - Low burden high speed trip relay Self-reset contacts and hand reset flag 2s drop out delay Aux. supply required 6RJ13- MVAJ13, MVAJ03 TR121 Low burden high speed trip relay 6RJ13- MVAJ13, MVAJ3 TR121 Hand reset contacts & flag 6RJ14- MVAJ14, MVAJ04 TR131 Low burden high speed trip relay 6RJ14- MVAJ14, MVAJ4 TR131 Electrical reset contacts Independent hand reset flag 6RJ1- MVAJ1, MVAJ0 TR141 Low burden high speed trip relay 6RJ1- MVAJ1, MVAJ TR141 Hand & electrical reset contacts Independent hand reset flag 2HSM02 2HSM21 2HSM04 2HSM06 2HSM09 6RJ21- MVAJ21, MVAJ01 TR212 High burden high speed trip relay 2HSM12 6RJ21- MVAJ21, MVAJ1 TR212 Self reset contacts 6RJ21-20 MVAJ201 TRA212 Hand reset flag 20 2HSM20 4M6-S 6RJ22- MVAJ26, MVAJ02 - High burden high speed trip relay 6RJ22- MVAJ26, MVAJ2 - Self-reset contacts and hand reset flag 2HSM21 6RJ22-20 MVAJ6-2s drop out delay 20 4M6-S 6RJ23- MVAJ23, MVAJ03 TR221 High burden high speed trip relay 6RJ23- MVAJ23, MVAJ3 TR221 2HSM14 Hand reset contacts & flag 6RJ23-20 MVAJ203 TRA M6-S 6RJ24- MVAJ24, MVAJ04 TR231 High burden high speed trip relay 6RJ24- MVAJ24, MVAJ4 TR231 Electrical reset contacts 2HSM16 6RJ24-20 MVAJ204 TRA231 Independent hand reset flag 20 4M6-S 6RJ2- MVAJ2, MVAJ0 TR241 High burden high speed trip relay 6RJ2- MVAJ2, MVAJ TR241 Hand & electrical reset contacts 2HSM19 6RJ2-20 MVAJ20 TRA241 Independent hand reset flag 20 4M6-S 3 rms

4 Pre-defined Relay Versions Auxiliary Flag Relays RMS Alstom Reyrolle Functional Description Contacts Case 6RA11 MVAA11 AR1, AR111, AR131 6RA12 MVAA12 AR114, AR124 6RA13 MVAA13 AR112 6RA1 MVAA1 AR3, AR113 Self-reset contacts / Hand reset flag Self-reset & hand reset contacts Hand reset flag Hand reset contacts & flag Hand & electrical reset contacts Independent hand reset flag 6 6RM202 2M28 6 6RM204 2M28 6 6RM206 2M28 6 6RM211 2M28 6RA20 - AR131, AR141, AR231, AR241 CT Shorting relay 6RM206 / 7 2M28 / 4M28 6RA23 MVAA23 AR212 Auxiliary flag relay 2 element Hand reset contacts & flag 6 x 2 6RM206 x2 2M28 Trip Circuit Supervision Relays RMS Alstom Reyrolle Functional Description Contacts Case 6RX11 MVAX11 Trip relay circuit supervision 2 1TM13 2M28 6RX12 MVAX12 XR12, XR13 Trip supply supervision 2 1TM11 2M28 6RX21 MVAX21 XR20, XR21 Trip circuit supervision 2 1TM 2M28 6RX31 MVAX31 XR30, XR21 Trip circuit supervision 3 element 2 1TM12 4M28 4 rms

5 Common Attributes Contact Bounce and Self Cleaning Contact bounce occurs due to the speed at which the contacts meet. If too much coil power is used then the contacts will come together with too much force causing excessive bounce. It is therefore important to only fit relay coils with adequate power to provide the force required to switch the relay at the minimum operate voltage 6% of nominal. In addition contact bounce can be greatly reduced through the addition of anti-bounce buffers. These components are added to each contact to provide a damping wiping motion when the contacts meet thus dissipating the force which would otherwise produce bounce. Contacts are constructed from silver / copper alloy, shaped & positioned to ensure very reliable, low resistance operation. Over travel of the contacts during each operation causes a wiping action ensuring a clean make. The design of the contact surface is spherical such that when the contacts are driven to an over travel position they actually wipe. This wiping motion is part of the damping action mentioned above but also provides a wiping action which serves to clean the contact area. relays are All or Nothing devices & continuous application of AC or DC voltages below the pick up level is not recommended. AC Voltages Standard 2HSM relays are not intended for operation with AC voltages. Application of continuous AC voltage below the pick up level will cause excessive power dissipation in the capacitor discharge resistor & likely result in thermal damage to the device. Contact Ratings Operating Voltage Isolation across open contacts Make and carry: Continuous Make and carry for 3s AC break capacity DC break capacity (Amps) Voltage free 1 kv rms 3,000 VA AC resistive 3,000 W DC resistive Limited at both 660 V and 12 A 7,00 VA AC resistive 7,00 W DC resistive Limited at both 660 V and 30 A 3,000 VA AC resistive Limited at both 660 V and 12 A Voltage 24V 48V 12V 300V Resistive Rating Inductive Rating L/R=40ms rms

6 Common Attributes Flag Indicators Each relay element is supplied with an operation (target) indicator. The indicator consists of a high visibility solid day glow orange mechanical flag which drops on energisation. Electrical Reset Mechanism Relay Wiring Diagrams All relays have a label attached to the internal side plate depicting the wiring information. As this stays with the product (unlike the paper wiring diagram also supplied), it cannot be lost. Operate voltage: Reset cut off: As per specified operate voltage. Instantaneous with main relay reset. Continuous application of both the high speed pick up coil & the reset coil will defeat the cut throat contact & result in overheating & thermal damage to both coils & associated circuit. Example of wiring diagram label fitted to side of draw out module 6 rms

7 Relay Monitoring Systems Pty Ltd design, manufacture and market a wide range of electrical protection and control products for application on high voltage power systems. The company's depth of local manufacturing and engineering expertise is backed up by many years of experience since the formation of its predecessor, Relays Pty Ltd (RPL), in 19. This experience combined with a broad base of field proven product types enables RMS to service specific customer needs by producing relays on demand with typically short lead times. R e l a y M o n i t o r i n g S y s t e m s P t y L t d 6 Anzed Court Mulgrave, Victoria 3170 Australia Ph: Fax rms@rmspl.com.au ISO9001 Quality Accreditation RMS holds BSI (British Standards Institute) registration number 6869 for the certification of a quality system to AS/NZS ISO9001:2008. Due to RMS continuous product improvement policy the information contained in this document is subject to change without prior notice. 201 Relay Monitoring Systems Pty Ltd ABN

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

2C138. Sensitive Earth Fault Relay. Features. Application. Operation Technical Bulletin 2C138 Sensitive Earth Fault Relay Features High sensitivity (0.1% of I n ) 2 nd & 3rd harmonic & HF noise suppression - tuned to 50 Hz Optional reset functions Instantaneous (Fast),

More information

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation 2T15 Multi Range Digital Setting Time Delay Relay Technical Bulletin Features Four time ranges -.99s, -9.9s, -99s, -99s High accuracy & repeatability timing compensated for output relay delay Time settings

More information

RMS Product Presentation

RMS Product Presentation RMS Product Presentation THE RELAY SPECIALISTS relay monitoring systems pty ltd www.rmpl.com.au Relay Monitoring Systems Pty Ltd 6 Anzed Court - Melbourne - Australia Manufacturing in Australia Company

More information

2V67 Four Stage Over / Under Voltage Relay

2V67 Four Stage Over / Under Voltage Relay Technical Bulletin 2V67 Four Stage Over / Under Relay Features Large graphics display panel Instantaneous voltage display 2 to 13V PU setting range.1v setting resolution Adjustable pick up & drop out Adjustable

More information

2H34. Definite Time Frequency Relay with ROCOF. Features. Operation. Application

2H34. Definite Time Frequency Relay with ROCOF. Features. Operation. Application 2H34 Definite Time Relay with ROCOF Technical Bulletin Features Large back lit display panel High resolution frequency & voltage display readout Four independent frequency s Independent time delay per

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

ABM Status Input Active Burden Module

ABM Status Input Active Burden Module Technical Bulletin ABM Status Input Active Burden Module Features Improve security of sensitive, high speed digital status inputs Provides capacitor discharge protection for solid state status inputs to

More information

6RJ User Guide. High Speed Tripping Relay. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide

6RJ User Guide. High Speed Tripping Relay. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide 6RJ User Guide High Speed Tripping Relay relay monitoring systems pty ltd Advanced Protection Devices User Guide Visit www.rmspl.com.au for the latest product information. 6RJ User Guide About This Manual

More information

2V67-S Four Stage Over / Under Voltage Relay

2V67-S Four Stage Over / Under Voltage Relay Technical Bulletin 2V67-S Four Stage Over / Under Voltage Relay Features Large graphics display panel Instantaneous voltage display 20 to 130V PU setting range 0.1V setting resolution Adjustable pick up

More information

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy Reyrolle Protection Devices 7SG117 Argus 7 Synchronising Relay Answers for energy 7SG117 Argus 7 Synchronising Relay Fig 1. Independent check & system synchronising settings Adjustable slip frequency,

More information

2C138 User Guide. Sensitive Earth Fault Relay. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide.

2C138 User Guide. Sensitive Earth Fault Relay. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide. 2C138 User Guide Sensitive Earth Fault Relay relay monitoring systems pty ltd Advanced Protection Devices User Guide Test Manual 2C138 User Guide About This Manual This User Guide covers all 2C138 relays

More information

2V67-S Four Stage Over / Under Voltage Relay

2V67-S Four Stage Over / Under Voltage Relay Technical Bulletin 2V67-S Four Stage Over / Under Relay Features Large graphics display panel Instantaneous voltage display 2 to 13V PU setting range.1v setting resolution Adjustable pick up & drop out

More information

REYROLLE. 2C73 User Guide. High Impedance Differential Relay. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide.

REYROLLE. 2C73 User Guide. High Impedance Differential Relay. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide. 2C73 User Guide High Impedance Differential Relay relay monitoring systems pty ltd Advanced Protection Devices User Guide Test Manual 2C73 User Guide About This Manual This User Guide covers all 2C73 relays

More information

4M200. Test Block System

4M200. Test Block System Test Block System > Colour coded finger safe test sockets > 14 independent test groups > Compatible with industry standard 14 circuit test blocks and test plugs > Optional auxiliary supply isolation circuit

More information

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy Reyrolle Protection Devices 7SG118 Argus 8 Voltage & Frequency Relay Answers for energy 7SG118 Argus 8 Voltage and Frequency Relay Data Storage and Communication Serial communications conform to IEC60870-5-103

More information

Auxiliary Units for 7SR23 High Impedance Protection Energy Management

Auxiliary Units for 7SR23 High Impedance Protection Energy Management Reyrolle Protection Devices Auxiliary Units for High Impedance Protection Energy Management Siemens Protection Devices Limited 2 Auxiliary Units for High Impedance Protection Description 7XG15 High Impedance

More information

Alpha AR User Guide. Auxiliary Relay. relay monitoring systems pty ltd Advanced Protection Devices. User Guide

Alpha AR User Guide. Auxiliary Relay. relay monitoring systems pty ltd Advanced Protection Devices. User Guide Alpha AR User Guide Auxiliary Relay relay monitoring systems pty ltd Advanced Protection Devices User Guide Visit www.rmspl.com.au for the latest product information. Alpha AR User Guide About This Manual

More information

Alpha TR User Guide. High Speed Tripping Relay. relay monitoring systems pty ltd Advanced Protection Devices. User Guide

Alpha TR User Guide. High Speed Tripping Relay. relay monitoring systems pty ltd Advanced Protection Devices. User Guide Alpha TR User Guide High Speed Tripping Relay relay monitoring systems pty ltd Advanced Protection Devices User Guide Visit www.rmspl.com.au for the latest product information. Alpha TR User Guide About

More information

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES

BE1-50/51M TIME OVERCURRENT RELAY ADVANTAGES BE1-50/51M TIME OVERCURRENT RELAY The BE1-50/51M Time Overcurrent Relay provides economical overload and fault protection for generators, transformers, lines and motors. ADVANTAGES Self powered from 50/60Hz

More information

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management

Reyrolle Protection Devices. 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay. Energy Management Reyrolle Protection Devices 7SG21 DDB20 Multi Range Digital Setting Time Delay Relay Energy Management 7SG21 DDB20 Digital Time Delay Induction disc reset emulation Replacement of induction disc timing

More information

7SG26 Tau Autoreclose and synchronization Answers for energy

7SG26 Tau Autoreclose and synchronization Answers for energy Reyrolle Protection Devices SG Tau Autoreclose and synchronization Answers for energy SG Tau Autoreclose and synchronization Fig 1. Tau relay in size 1 case Description The Tau range of auto-reclosing

More information

Zelio Control-modular measurement and control relays 1

Zelio Control-modular measurement and control relays 1 Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and

More information

7XG225-3RMLG Test Block System Answers for infrastructure & cities.

7XG225-3RMLG Test Block System Answers for infrastructure & cities. Reyrolle Protection Devices 7XG5-3RMLG Test Block System Answers for infrastructure & cities. Siemens Protection Devices Limited 7XG5-3RMLG Test Block System Application Test blocks enable test technicians

More information

RM4TA32 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 380..500 V Complementary [Us] rated supply voltage Output contacts Main Range of product Product or component type Relay type Product specific

More information

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Type MVTT 14 and MVTT 15: Static Digital Time delay relays Type MVTT 4 and MVTT 5: Static Digital Time delay relays Features 000/ setting range Time settings easily selected by means of thumbwheel switches Provide time delayed pick-up, or drop-off Compact construction

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

RM4TR31 three-phase network control relay RM4-T - range V

RM4TR31 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 160..220 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold

More information

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time

More information

Residual overvoltage relay

Residual overvoltage relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Definite-time residual overvoltage earthfault protection and supervision Two independent operation stages, e.g. one

More information

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay

More information

4M200. Test Block System. rms. Flexible and high-performance test block system suitable for application on a wide range of protection relay panels.

4M200. Test Block System. rms. Flexible and high-performance test block system suitable for application on a wide range of protection relay panels. T E S T B L O C K S T E S T P L U G S T E S T L E A D S Test Block System Flexible and high-performance test block system suitable for application on a wide range of protection relay panels. > Colour coded

More information

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION

www. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION The Motor Protection System is a microprocessor based digital relay which provides comprehensive motor protection including metering, communications, data recording and diagnostics. ADVANTAGES Extensive

More information

MRA1 Trip circuit supervision. Manual MRA1 (Revision A)

MRA1 Trip circuit supervision. Manual MRA1 (Revision A) MRA1 Trip circuit supervision Manual MRA1 (Revision A) Woodward Manual MRA1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

RM4JA01F current measurement relay RM4-J - range ma V AC

RM4JA01F current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

Diodes or VDR s fitted internally if requested.

Diodes or VDR s fitted internally if requested. C & S Controls Ltd. 22 Upland Road, Bexleyheath, Kent, DA7 4NR. Tel: Fax: Email: Web: +44 (0)208 304 4882 +44 (0)208 301 1938 sales@candscontrolsltd.com www.candscontrolsltd.com Relay High integrity plug-in

More information

Circuit Breaker Analyzer System

Circuit Breaker Analyzer System Programma TM1600 TM Circuit Breaker Analyzer System Modular Design configure the analyzer to your needs Ideal for timing of breakers with multiple breaks per phase 16 Timing Channels and 6 Analog Channels

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching

More information

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A) IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O Characteristics industrial timing relay - 0.3..30 s - type A - 24 V AC/DC, 110..240 V AC - 1 C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

NSE relay - Over- and undervoltage

NSE relay - Over- and undervoltage - Over- and undervoltage Datasheet monitoring Features Overvoltage and undervoltage monitoring relay with delay on pull-in AC input (50 Hz) 2 C/O contacts Overvoltage and undervoltage adjustable via lockable

More information

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM4JA32MW current measurement relay RM4-J - range A V AC DC Characteristics current measurement relay RM4-J - range 0.3..15 A - 24..240 V AC DC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in

More information

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay IE ON RESET.5 X1 t IE X1.6%.2.4.8 1.6 X1.1s.2.4.8 1.6 X2 OFF ON S1 S2 IRI1-ES IRI1-ES C&S Electric Limited (Protection & Control Division) Contents

More information

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Characteristics sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Main Range of product Product or component type [Us] rated supply voltage Number of channels 16 Number of terminal

More information

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New) XU1-E Earth fault voltage relay (August 1996) Manual XU1-E (Revision New) Woodward Manual XU1-E GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294

More information

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC Characteristics off-delay timing relay with control contact - 0.05..1 s - 24 V AC DC - 1OC Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A Complementary Shape of pin Main Range of product Series name Product or component type Device short name Contacts type and composition

More information

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Characteristics sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm Main Range of product Product or component type [Us] rated supply voltage Number of channels 16 Number of terminal

More information

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New)

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New) XU1-DC DC voltage relay (June 1998) Manual XU1-DC (Revision New) Woodward Manual XU1-DC GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications

More information

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC Characteristics on-delay timing relay - 0.02 s..300 h - 24..240 V AC - 2 OC Product availability : Stock - Normally stocked in distribution facility Price* : 73.00 USD Main Range of product Product or

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range [Us] rated

More information

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O Characteristics industrial timing relay - 0.3..30 s - type Qc - 24 V AC/DC, 110..240 V AC - 1C/O Main Range of product Product or component type Component name Time delay type Time delay range Sep 23,

More information

High impedance protection relay

High impedance protection relay High impedance protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features High impedance type differential current earth-fault protection, so called restricted

More information

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems.

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems. DIAC/DIFC/DSFC Single Phase Digital O/C DIAC DIFC DSFC Single phase or ground overcurrent protection for industrial and utility power systems. Features and Benefits models: DIAC, DIFC, DSFC Direct/functional

More information

INSTALLATION GUIDE NP800R

INSTALLATION GUIDE NP800R INSTALLATION GUIDE ICE - 11, rue Marcel Sembat - 94146 ALFORTVILLE CEDEX - France TEL. : (33) 01 41 79 76 00 - FAX : (33) 01 41 79 76 01 E-MAIL : contact@icelec.com SITE WEB : www.groupeice.com File: A662A

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC Characteristics on-delay timing relay - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical

More information

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay

More information

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives TM MODERNIZE YOUR DC CRANES Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives Magnetek, the leader in digital power and motion control systems, brings you the

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED Characteristics power plug-in relay - Zelio RPM - 4 C/O - 230 V AC - 15 A - with LED Complementary Shape of pin [Ui] rated insulation voltage Main Range of product Series name Product or component type

More information

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters Ergonomic Design a Make Performance RFD-200 TM Vanguard s Model RFD-200 S2 is a portable relay test set that delivers performance verification testing of electromechanical, electronic, and microprocessorbased

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Q22 DATRAN II excel Owners Manual

Q22 DATRAN II excel Owners Manual Q22 DATRAN II excel Owners Manual Manual Revision No. 1.03 Dated November 2001 Copyright 2000 to QTech Data Systems Limited Christchurch, NEW ZEALAND All rights reserved The circuit details and know how

More information

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A) XE2 DC current relay for loss of excitation protection Manual XE2 (Revision A) Woodward Manual XE2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA Characteristics phase control relay RM17-T - range 183..484 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Switching

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

D2600 Relay. 1. Relay Types. 2. Technical Data

D2600 Relay. 1. Relay Types. 2. Technical Data C & S Controls Ltd. Upland Road, Bexleyheath, Kent, DA7 NR. Tel: Fax: Email: Web: + (0)08 30 88 + (0)08 30 938 sales@candscontrolsltd.com www.candscontrolsltd.com D00 Relay High integrity plug-in relays

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02 IQM & IQML RANGE CONTROL AND MONITORING FACILITIES Publication E0E issue 7/0 IQM - STANDARD FACILITIES SPECIFICATION The type IQM actuator specification is generally as described in Publication No. E0E

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

RM4UA33M voltage measurement relay RM4-U - range V V AC

RM4UA33M voltage measurement relay RM4-U - range V V AC Characteristics voltage measurement relay RM4-U - range 30..500 V - 220..240 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay Power consumption

More information

1S24 User Guide. Arc Fault Monitoring System. relay monitoring systems pty ltd Advanced Protection Devices. User Guide

1S24 User Guide. Arc Fault Monitoring System. relay monitoring systems pty ltd Advanced Protection Devices. User Guide 1S24 User Guide Arc Fault Monitoring System relay monitoring systems pty ltd Advanced Protection Devices User Guide Visit www.rmspl.com.au for the latest product information. 1S24 User Guide About This

More information

High Voltage Contactors

High Voltage Contactors High Voltage Contactors Contents Page 1.0. Application...3 2.0. Power Rating...3 3.0. Device Data...4 3.1. Electronic Contactor Type ZH 767E / 767F... 4 3.2. Contactor Type ZH 829...5 3.3. Contactor ZH

More information

REOHM series 154 Max. continous power: 200 W

REOHM series 154 Max. continous power: 200 W Descripción The braking resistor REOHM 154 protects the machine from a voltage rise in the intermediate circuit, if an electric machine operates as a generator (Electromotive brake). The current reduces

More information

satech TSB-14 MAIN FEATURES

satech TSB-14 MAIN FEATURES satech TSB-14 ARTECHE satech TSB test block allows the testing of the protection relay, in a safe and easy way, ensuring isolation between the relay and field elements and eliminating any risk for the

More information

Latching, Sequence and Impulse Relays Application Data

Latching, Sequence and Impulse Relays Application Data Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation

More information

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4JA31M current measurement relay RM4-J - range ma V AC Characteristics current measurement relay RM4-J - range 3..1000 ma - 220..240 V AC Complementary [Us] rated supply voltage Operating voltage tolerance Main Range of product Product or component type Relay

More information

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC 100% ity Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration

More information

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC Characteristics phase control relay RM17-T - range 183..484 V AC Complementary Maximum switching voltage Minimum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage

More information

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point January 2010 PACSystems RX3i and Series 90-30 IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TB IC694MDL916 Q1 Q2 Q3 Q4 Q5 Q6 Q7

More information

C-Bus Four Channel Voltage Free Relay Installation Instructions

C-Bus Four Channel Voltage Free Relay Installation Instructions C-Bus Four Channel Voltage Free Relay Installation Instructions 5504RVF Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3

More information

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

High Impedance Protection Relay SPAE010, SPAE011. Product Guide SPAE010, SPAE011 SPAE010, SPAE011 1MRS750383-MBG Issued: April 1999 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features High impedance type differential current earth-fault

More information

93 SERIES. Timed socket for 34 series 93.68/93.69

93 SERIES. Timed socket for 34 series 93.68/93.69 93 93 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions

More information

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections - terminals Housing material Main Range

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

RF119. w w w. r m s p l. c o m. a u R F 119 B 4 08/ 01/

RF119. w w w. r m s p l. c o m. a u R F 119 B 4 08/ 01/ Relay Adaptor System Based on the flexible Siemens Reyrolle 7SR11 Non-Directional Overcurrent Relay, the Adapter Modules allows the replacement of obsolete draw-out protection relay modules without disturbing

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face, bright LED illumination in choice of red, green, and amber for visible status indication. 9-amp or 6-amp electrical capacity in compact body. Interior shield prevents

More information

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK) Characteristics Instantaneous (RHN) and latching (RHK) Type RHN RHK Environment Classification Standard version EDF, BV, USSR Conforming to standards Standard version IEC 255, NF C 45-25, VDE 435, BS 4794

More information

Earth Continuity Monitor

Earth Continuity Monitor Continuity Monitor For Model systems switching ELECTRONIC ENGINEERS Leaders in : Voltage-Dip Proofing Continuity Monitoring Contents Introduction... 3 Theory of operation... 3 Description... 4 Front panel

More information