1 SPT1000 Fuel Management System Installation Manual Revision 1 August 2012
2 Introduction The SPT1000 Fuel Management System provides a complete solution for the operation and management of attended and/or unattended fueling systems. It allows the operator to control, monitor, and manage all aspects of a fuel dispensing facility via secure internet connection from anywhere in the world. The SPT1000 has a number of advanced features, including: Ready to process Chip&PIN transactions. Accepts credit cards, debit cards, fleet cards and proprietary cards. Works with all major pumps including Kraus, Wayne, Gilbarco, and Tokheim. Provides customer with fueling safety instructions. Automatically sends alarm and warning messages via pager or . Operates in extreme weather conditions. Warning This manual contains important information about the SPT1000 Fuel Management System. Please read all of the information contained in this manual to ensure proper and safe operation. Failure to installation the system properly may create hazardous conditions resulting in injury to personnel and/or damage to the system. Page 2 of 25
3 Typical System Components Designed specifically for Kraus dispensers equipped with Micon 500 registers, the SPT1000 Fuel Management system also works with other major brands of dispensers, including Wayne, Gilbarco, and Tokheim when they are equipped with their respective Dispenser Control Interfaces. Contact Computrol to check if your model of dispenser is supported. Dispensers utilizing Kraus Micon 500 registers don t require a Dispenser Control Interface because the necessary interface is built into the SPT1000 Communications Box circuitry. Up to eight Micon 500 registers are supported and communication is via the Micon 500 MNET protocol using a three-wire interface (TTP talk to pump, TTC- talk to console, and COM- common). Important! Ensure that the Micon 500 has the SK472 MNET communications piggy-back chip (Computrol part number ) installed in the Kraus head. SPT1000 Fuel Management Terminal The SPT1000 Fuel Management Terminal consists of a LCD Display, Tamper-proof Stainless Steel Keypad, Chip/Magnetic-Stripe Card Reader, and Thermal Receipt Printer. These devices are controlled by a microprocessor located on the main board behind the display. The processor board contains serial data ports which are used to communicate between the SPT1000 Terminal and the Site Computer. Additionally, the SPT1000 contains a regulated power supply to convert AC power to clean Direct Current for the electronics and a thermostatically Page 3 of 25
4 controlled heater is incorporated to ensure proper operation in cold temperatures. SPT1000 Site Computer The Site Computer is a Windows7 based computer outfitted with special hardware to ensure reliability. It runs an InfoNet application called FuelCommanderiX. This program controls the SPT1000 Terminal and processes transactions. Additional applications for Fleet Management and Banking Services also run on the Site Computer. Refer to their respective manuals for information on these applications. SPT1000 Communication Interface Box The Communication Box provides converts two RS-232 serial data channels to RS-485. RS-485 can be transmitted over much longer distances than can RS-232, so one channel of the Communication Box is used to connect the Site Computer to the SPT1000 Terminal, while the other channel is used to connect the Site Computer to Kraus Micon 500 registers. Page 4 of 25
5 Dispenser Control Interface The Dispenser Control Interface is only required for systems using Wayne, Gilbarco, Tokheim, or other non-kraus dispensers. It is not required if the dispensers are equipped with Kraus Micon 500 registers. Dispenser Control Interfaces vary according to the pump manufacturer, and generally consist of an electronic interface which converts the serial data language, plus a separate distribution box (D-box) which allows for connection of several dispensers. Cable or DSL modem A Cable or DSL modem is often used to process card transactions as well as allow remote access to the system. Remote access can be used for online reporting, monitoring, and dispenser control. It can also be used to change product pricing, and for connecting to the banking service. Although Cable or DSL modems can be obtained through the assistance of Computrol, they are most often supplied by the Internet Service Provider (ISP) when the service is ordered. A static IP address is required for the Cable or DSL modem. Page 5 of 25
6 Uninterruptible Power Supply (UPS) The UPS serves two purposes. It provides a filtering function to eliminate voltage spikes and noise commonly found on mains lines. Secondly, it continues to provide power to the SPT1000 system in the event of a power outage so that any transactions in progress at the time of the outage can be completed. The UPS provides power to the Site Computer, Communications Box, SPT1000 Terminal, and Micon500 registers if Kraus dispensers are used. A UPS rated for at least 1000 VA is recommended for systems with one SPT1000 terminal and up to 4 Kraus heads. For systems with more than 4 Kraus heads, a capacity of 1400VA or higher is recommended. Page 6 of 25
7 ******************************************************************************************** This page is where the 11 X 17 foldout drawing goes. ******************************************************************************************** Page 7 of 25
8 Location and Site Preparation The site owner is responsible for all site preparation, electrical wiring and connections. This work must be done in accordance with applicable National, State/Provincial, and Local Building and Electrical codes. The SPT1000 Fuel Management Terminal is designed for installations outside of Class II hazardous locations. The unit must be at least 18 inches (46cm) away from conventional pumps, and 24 inches (61cm) from overhead pumps or dispensers. Approved Electrical Y Seal (EYS) connectors must be used in accordance with all applicable electrical codes. All peripheral equipment connected to the system must be UL or CSA listed and be equipped with suitable interfaces for use with the SPT1000. All field-installed electrical wiring connected to the SPT1000 Pump Control Unit must be rated for operation at a minimum temperature of 90 C (194 F). High voltage (120VAC) conductors must be 12 AWG minimum. Low voltage conductors should be a minimum of 20 AWG. Free space in the junction box(es) feeding the Pump Control Unit (usually located in the pedestal) must not be less that the minimums shown in the table below: Conductor Size (AWG) Free space within Junction Box for each conductor. Box with Hubs Box without Hubs 16 or smaller 22 ml (1.3 cu in.) 25 ml 1.5 cu in.) ml (1.8 cu in.) 33 ml (2.0 cu in.) ml (2.0 cu in.) 37 ml (2.25 cu in.) ml (2.2 cu in.) 41 ml (2.5 cu in.) 8 45 ml (2.7 cu in) 60 ml (3.6 cu in) Each conductor that passes through the box is counted as one conductor as is each conductor that terminates in the box. No unplugged openings are permitted. Table 1 Junction Box minimum free space per conductor. Page 8 of 25
9 Conduit Routing The bottom of the SPT1000 Terminal enclosure has an opening. The opening is designed to accommodate standard 1 inch conduits. The left-side conduit should be used for the low voltage circuits while the right-side conduit is reserved for high-voltage circuits. A customer-supplied junction box may be utilized to collect conductors from several smaller conduits and route them through the appropriate high or low voltage conduit into the SPT1000 PCU. The junction box may be installed in the pedestal provided that it is installed in accordance with all applicable electrical codes. Rigid steel conduit is recommended for both high and low-voltage wiring to the SPT1000 Pump Control Unit as it provides better immunity from electrical noise than does aluminum or PVC. Page 9 of 25
10 Base Plate Installation The SPT1000 Terminal is supplied with a Base Plate designed specifically for use with the SPT1000 Terminal. The Base Plate comes with four pre-drilled mounting holes and embedded bolts to secure the SPT1000 to the pump island. 1) Prepare the pump island by installing four bolt-studs and conduits (as many as required). 2) Position the Base Plate on the four mounting bolts of the fuel island and secure it to the pump island using split washers and nuts. Page 10 of 25
11 SPT1000 Terminal Mounting 1) Position the Terminal on the four mounting bolts of the Base Plate and secure it to the Base Plate using split washers and nuts. The removable panel must be oriented to the front of the SPT1000 Terminal. 2) Mount junction boxes, etc in the pedestal, being sure to observe national and local electrical codes. SPT1000 Terminal Wiring The bottom of the SPT1000 Terminal facilitates two 1 wiring conduits. Usually, the one on the right is used for high-voltage AC power, while the one on the left is used for the low voltage serial data wires that run to the Communication Box. 1 rigid steel conduit is required. Aluminum or PVC is not acceptable. Explosion proof EYS connectors must be installed on both ends of the conduits. The power conduit must be able to accommodate six 12 AWG stranded conductors. The low voltage serial data conduit must be able to carry two 20 AWG two-pair shielded cables and a CAT 5 cable. Junction boxes can be installed above the EYS connectors in the pedestal for the convenience of joining electrical connections. Flexible, armored and seal tight (rubber covered) conduit must be used from the EYS connector carrying the AC power to the utility boxes. See the drawing below. Page 11 of 25
12 As an alternative to rigid conduit, an armored cable suitable for direct earth burial may be used. TEK 90 power and instrumentation cable is one such cable. See Appendix B for details. Warning! Do not use conduit as a grounding wire. Provide grounding wire sized in accordance with local electrical codes for power wiring. Connect one end of grounding wire to Load Center s ground and the other to the grounding Terminal in the SPT1000 Terminal enclosure. Page 12 of 25
13 120 VAC wiring The SPT1000 Terminal power supply must be wired to a 120 VAC 60 Hz UPSbacked power supply. Maximum current draw is 5 Amps. The UPS is usually housed in the same building as the Site Computer and also supplies power to the Site Computer and Communications Box. Ensure that the 120VAC power cable to the SPT1000 Terminal is properly sized to carry the required current. The SPT1000 Terminal is internally equipped with two sets of receptacles, one for UPS power and one for non-ups power. Terminate the UPS AC power line to the UPS AC receptacle box and non-ups AC power line to the non-ups AC receptacle box. Ensure that the ground wire from each incoming line is properly connected to the ground screw inside its respective receptacle box. See the drawing below. Page 13 of 25
14 The Heater/Fan module must be plugged into the non-ups AC receptacle. The internal power supply must be plugged into the UPS AC receptacle. In the event of a power loss, Micon 500 registers are equipped with a small battery designed to power the register for a short time so that any transactions in progress can be completed. However, usable battery life can be affected by temperature and age. To ensure that all transactions are processed properly, we recommend that the Micon 500 registers be powered from an Uninterruptible Power Supply. The same UPS that powers the SPT1000 Terminal and Site Computer may be used. However, some rewiring of the Micon 500 registers may be necessary: The 120VAC supply input to the Micon 500 registers must be separated from the 120 VAC that supplies the rest of the Kraus head, pump motors, lights, etc. See the drawing on the next page. Page 14 of 25
15 MICON 500 CIRCUIT BOARD 120VAC HOT from UPS 120VAC NEUTRAL from UPS CTR 120VAC HOT PUMP STARTER CTR 120VAC NEUTRAL 110VAC Ground 1 2 3A 3B HEAD POWER (18AWG, BLACK) NEUTRAL (18AWG, WHITE) GROUND (18AWG, GREEN) GROUND (18AWG, GREEN) SOLENOID CONTROL OUTPUT (18AWG, ORANGE) PUMP MOTOR/SOLENOID POWER INPUT (14AWG, BLACK) PUMP MOTOR CONTROL OUTPUT (14AWG, ORANGE) AUTHORIZE INPUT (18AWG BROWN) AUTHORIZE RETURN (18AWG, GREY) MONEY PULSER + (18 AWG, YELLOW) MONEY PULSER - (18AWG, RED) VOLUME PULSER + (18AWG, BLUE) VOLUME PULSER - (18AWG, WHITE/BLUE) TTP from COMMUNICATIONS BOX TTC to COMMUNICATIONS BOX DCC from COMMUNICATIONS BOX TTP - TALK TO PUMP (18AWG, PINK) TTC - TALK TO CONSOLE (18AWG, TAN) DCC - DATA COMM. COMMON (18AWG, GREEN) -- (WHITE/BROWN) SOLENOID VALVE DISPENSER LIGHT Page 15 of 25
16 UPS Wiring The UPS should be supplied from a dedicated 120VAC circuit breaker. Whenever the UPS is shipped or transported to a new location, the internal battery must be disconnected in order to comply with government regulations. Before the UPS is turned on, the battery must be reconnected as shown in the photos below or the SPT1000 system power will not be backed-up in the event of a mains power loss. Emergency Stop Circuit (optional) An Emergency Stop circuit must be installed in accordance with local and national safety regulations. A multi-contact switch or switch-activated relay circuit should be used to interrupt both the UPS-backed power to the SPT1000 Terminal and Micon 500 registers, as well as the 120 VAC power used for the dispenser pumps circuits. Page 16 of 25
17 Serial Data Wiring Serial Data communication between the SPT1000 Terminal and the Communication Box is accomplished by means of two conductors over a shielded cable. The signals are DAT+ and DAT-. The shield should be connected at the Communications Box only. Warning! Do NOT connect the Serial Data shield inside the SPT1000 Terminal to the chassis, signal ground, or any part of the 120 VAC circuitry. Belden cable, catalog number 8723 or its equivalent is a suitable cable for use as serial data cable in this application. Because the serial data is transmitted in RS- 485 format, distances up to 600 feet should not cause any problems in communications provided that adequate shielding is provided. Connect the Serial Data cable to the SPT1000 Terminal wiring block located between the Fan/Heater module and the Annunciator as shown below. Page 17 of 25
18 Communication Box Wiring Computrol supplies serial data cables that are 6 feet (2 meters) for connection of the Communication Box to the Site Computer. These cables may be extended up to 50 feet (15 meters) if mounting circumstances require it. Exceeding this distance may cause unreliable operation of the system. The Communication Box is provided with four mounting holes on flanges for easy mounting, and may be mounted in any orientation provided that there is sufficient access for the various cables to be run through the access hole, and that the lid can be opened for inspection, installation, and servicing. Box dimensions are shown below: Page 18 of 25
19 Below is a diagram showing the electrical connections inside the Communications Box. Refer to the following paragraphs for more detail. Power Supply Warning! The Communications Box circuitry is designed to run only off of a regulated 12VDC power supply. Do not replace the power supply with an unregulated supply. Using the wrong supply will cause damage to the circuitry which is not covered under warranty. Page 19 of 25
20 Connections to Site Computer Connect one serial cable from COM1 on the Site Computer to the DE-9 connector on the Communication Box circuit board labeled KIOSK. If the SPT1000 system is controlling Kraus dispensers with Micon500 registers, connect a second serial cable from COM2 on the Site Computer to the DE-9 connector on the Communication Box circuit labeled PUMP. If the SPT1000 system is controlling dispensers that do not have Micon500 registers, the PUMP connector is not used. By default, COM1 on the Site Computer is dedicated to communicating with the SPT1000 Terminal, and COM2 is dedicated for communication with the dispensers/pumps. If you change these settings in the system configuration software files, you will need to re-route the cables to their new COM ports so they match the system configuration. Be sure to mark the changes on diagram above for future reference. When the Communications Box is communicating with the Site Computer, the red and green LED lamps near the KIOSK and PUMP connectors on the Communications Board will blink. These LEDs are labeled TX and RX. When the Site Computer is transmitting to the Terminal or to the dispensers, the TX lamp will blink. When the Site Computer is receiving data from the Terminal or the dispensers, the RX lamp will blink. Page 20 of 25
21 Connections to SPT1000 Terminal As stated previously, serial data communication between the SPT1000 Terminal and the Communication Box is accomplished by means of two conductors over a shielded cable. Use only twisted, individually shielded pair cable, suitable for use in high-speed RS485 networks. The signals are DATA+ and DATA- which correspond to DAT+ and DAT-, respectively, in the SPT1000 Terminal. The shield should be connected at the Communications Box only. The serial data connections are wired to plug P305, which is subsequently inserted into jack J305. Connections to Micon 500 registers Connection to the Micon 500 registers is made by means of a three-conductor data cable. Belden cable, catalog number 8723 or its equivalent is a suitable cable for use in this application. Use two twisted pairs for each dispenser, taping off the unused conductor. Best performance is realized if each dispenser has a dedicated data cable running from Communication Box to the Micon 500 register. However, if the distance from the Communication Box to the dispensers is long, it may be more economical to connect the dispensers in a daisy-chain fashion. Combinations of dedicated and daisy-chained runs are also possible. The three signal lines are TTP (Talk-To-Pump), TTC (Talk-To-Communication- Box) and DDC (Data Communications Common). Eight such connections are provided, and are clearly labeled on the Communication Box circuitry board, and connection is made via one of the two twelve-position plugs which fit into jacks on the board. Page 21 of 25
22 Site Computer The Site Computer should be installed in an area that is secure, warm, and dry. The Site Computer should be dedicated to the operation of the SPT1000 Fuel Management System, and should not be used for other applications. The Site Computer should be supplied with power from the UPS. Site computer Wiring Refer to the fold-out drawing Installation Overview. This drawing shows the Site Computer connections. Following are details of those connections: 1) Connect COM1 to the KIOSK connector in the Communication Box. 2) If the site uses Kraus pump heads with Micon 500 registers, connect COM2 to the PUMP connector in the Communication Box. 3) If the site uses Wayne, Gilbarco, Tokheim, or other pump heads, then connect COM2 to the appropriate Dispenser Control Interface. 4) Connect the Site Computer s RJ-45 network port to your network via the Ethernet cable provided. 5) Connect the monitor, keyboard and mouse to the Site Computer. Page 22 of 25
23 Appendix A Specifications SPT1000 Terminal Specifications Dimensions (H x W x D) (approx.) Weight Ambient Temperature Rating Power Requirements 1500mm x 510mm x 357mm [59 x20 x14 ] 28 kg [61.7 lbs] -40 C to +45 C [-40 F to 110 F] 120 VAC, 60 Hz, 5 Amps Communications Box Specifications Dimensions (approximate) Weight Ambient Temperature Rating Power Requirements 221mm x 294mm x 157mm [8.7 x 11.7 x6.2 ] 3.86kg [8.5 lbs] 0 C to +30 C [32 F to 85 F] 12 VDC, 0.5 Amps Page 23 of 25
24 Appendix B TEK 90 Cable Specifications TEK 90 Armoured Control & Instrumentation Cable 300Volts, PVC Insulation Stranded Tinned Copper Conductor. OS AIA PVC Insulation. Individually Shielded Pairs or Triad. Aluminum Armoured with Inner and Outer PVC Jacket. FT-4 Flame Rated, 105 C dry, 75 C wet and -40 C Application: Suitable for installation in cable trays in dry, damp and wet locations or for direct burial and may be extended through sealing glands without removal of the individual shields, when installed in Hazardous Locations containing A, B, C & D atmospheres as defined by the Canadian Electrical Code. Specifications: Conductor: Conductor is 7 stranded tinned copper 22 AWG to 16 AWG Insulation: PVC compound suitable for 105 C dry, 75 C wet and -40 C Print: (Size) AWG 300V CSA INSTRUMENTATION CABLE ACIC LL C WET/105 C DRY PVC SHIELDED (-40 C) FT-4 HLABCD OUTDOOR Page 24 of 25
25 System & Replacement Parts Warranty Information SPT1000 fuel management Computrol Fuel Systems Inc. ( Computrol ) warrants that all electric or electronic equipment, including accessories manufactured by Computrol will be free from defects in material and/or workmanship under normal use and service for a period of 12 months from the date of installation, at the location chosen by the Purchaser (the "Warranty Period ). If a defect in the Equipment becomes apparent during the Warranty Period, Computrol will repair or replace the defective Equipment at its facility. The warranty will not extend to goods subjected to misuse, neglect, accident, or improper installation or maintenance or which may have been altered or repaired by anyone other than Computrol Fuel Systems Inc. or its authorized representative. The buyer s acceptance of delivery of the goods constitutes acceptance of the foregoing warranties and remedies, and all conditions and limitations thereof. Purchaser must notify Computrol in writing of any defect in the Equipment within fourteen (14) days of discovery of the defect and obtain a Return Approval (RA) number before returning the defective equipment prepaid to Computrol s facility. The Equipment must be suitably packed and insured for shipping to Computrol s facility at Purchaser s risk and expense. After repair or replacement of the defective Equipment, Computrol will ship the Equipment to the Purchaser F.O. B at the Purchaser s address. Computrol s liability under this Warranty shall be limited to repair or replacement of defective Equipment and shall in no case exceed the purchase price of the Equipment sold herewith. Computrol shall make reasonable repairs, replacement and corrections within reasonable time but shall not be liable for the delay in the repair or replacement. The foregoing Warranty is in lieu of all other warranties, express or implied. Computrol Fuel Systems Inc. shall not be liable for any direct, indirect, incidental or consequential damage or loss of product. *************************************************************************************************************** Page 25 of 25
FIT. Fuel Island Terminal Installation and Operation Manual. The material in this manual is subject to engineering changes and editorial revisions
FIT Fuel Island Terminal Installation and Operation Manual The material in this manual is subject to engineering changes and editorial revisions Copyright 2002 OPW Fuel Management Systems OPW Fuel Management
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More informationInstallation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2
Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationPDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL
PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL
LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND
More informationRAYMAPB. Power Supply and Terminal Box for Marathon MM/MR/FA/FR Sensors. Manual Addendum. Rev. A 06/
RAYMAPB Power Supply and Terminal Box for Marathon MM/MR/FA/FR Sensors Manual Addendum Rev. A 06/2014 51001 Contacts Worldwide Headquarters Santa Cruz, CA USA Tel: +1 800 227 8074 (USA and Canada only)
More informationTHE CTB08D LIGHT CONTOLLER
THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More informationBid Specifications and General Description
BID-SPEC_PV100 Rev. 0 Bid Specifications and General Description OPW Petro Vend 100 Fuel Control System Part 1. General Overview 1.1 Summary This document describes the minimum required technical and compliance
More informationMD9 MULTIDROP INTERFACE INSTRUCTION MANUAL
MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by
More informationTornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller
Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates
More informationElapsed Timer Control Panel
Installation Manual V6.2 Elapsed Timer Control Panel Current as of August 2017 The Sapling Company, Inc. Elapsed Timer Control Panel Table of Contents Table of Contents 2 Important Safety Instructions
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More informationSVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL
SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL REVISION: 01/03/03 COPYRIGHT (c) 1995-2000 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The SVP110 SURGE VOLTAGE PROTECTOR is
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationDVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8
DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all
More informationQuickTouch (QT4) Owner s Manual
QuickTouch (QT4) Owner s Manual 4-Function Hand-Held Wireless Remote Control IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. APPLICATION...
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationLINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.
LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MODEL 2150 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many
More informationRE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007
RE-82 RACK MOUNT DIMMER 8 X 2400Watts OWNERS MANUAL Revision 2.4 11/29/2007 Page 2 of 8 RE-82 CONTROL PANEL DESCRIPTION The RE-82 is an 8 channel dimmer with a maximum capacity of 2,400 watts per channel
More informationWARRANTY & LIMITATION OF LIABILITY
MUX-485 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)
More informationDIRECT POWER LIGHTING MANUAL
SS2 -RGBW RGBW-18L DIRECT POWER LIGHTING MANUAL Coloronix, Inc. 5461 West Jefferson Boulevard Los Angeles, California 90016 (323) 677-4242 http://www.rgbw.com Summary Introduction RGB Color Changing Adjustable
More informationPI DBOX. Installation Guide for Current Loop Style, Tokheim Style, RS485 Style, Kraus Style, Bennett Style, and EZwire Style
PI DBOX for Current Loop Style, Tokheim Style, RS485 Style, Kraus Style, Bennett Style, and EZwire Style 1106 Great Falls Court, Suite G Knightdale, NC 27545 Phone 919 266-4442 Fax 919 266-4588 www.pie-corp.com
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF
More informationLPG STM 94442A User s Manual
1 LPG STM 94442A User s Manual This Manual belongs to: Company: 3 Table of Contents Features....... 4 Hardware Installation...5 Monitor Mounting Dimensions.....7 Monitor Specifications...8 Sender Specifications.....9
More informationIndoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range
Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting
More informationOWNER S MANUAL Calc-U-Dri PRINTER
OWNER S MANUAL Calc-U-Dri PRINTER PNEG-1141 Date: 9-21-06 PNEG-1141 Calc-U-Dri Printer TABLE OF CONTENTS Limited Warranty... ii Safety Information - Please Read...iii CAUTION! Be a Safe Operator...iv Decal
More informationPRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Jamieson Equipmen toll free 800
PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4 3.0 INSTALLATION...4
More informationCRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)
CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional
More informationOPERATING AND SERVICE MANUAL. Universal Interface Device 47
OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects
More informationSapling Converter Box
Installation Manual Sapling Converter Box SCB-100-000-1 Version Number 1.2 Current as of March 15, 2015 The Sapling Company, Inc. (+1) 215.322.6063 P. (+1) 215.322.8498 F. 2-Wire Converter Box (SCB-100-000-1)
More informationPS8 - II. Professional Power Sequencer. User s Manual
PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.
More informationicp installation guide
The Information Control Point (icp) is the latest SmartFarm Technology by Inc. The icp is the ultimate on-farm data-management tool. The icp has all the power of a basic personal computer, but instead
More informationWARRANTY & LIMITATION OF LIABILITY
MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)
More informationSafegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016
Safegard V4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly
More informationCFN IslanderI & II Installation Quotation Guide
OPERAT OR INSTR UC TIONS CFN IslanderI & II Installation Quotation Guide (For Quotation Use Only - Do Not Install From This Guide) This document is provided as a guide for quoting the installation of a
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MP-259/220, MP-259/220V, MP-259/220W, MP-269/220, MP-269/220V, MP-269/220W BASKETBALL SCOREBOARDS OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your
More informationDigital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03
Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The
More informationPCM-7140 Pulsed Current Source Operation Manual
PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031
More informationNSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK
INTRODUCTION NSI DIGITAL DIMMING SYSTEM INSTALLATION AND OPERATION GUIDE The NSI DDS 5300 and DDS 5600 dimmers represent a key part of a state of the art, integrated lighting control system. These dimmers
More informationELECTRO-MECH SCOREBOARD CO.
ELECTRO-MECH SCOREBOARD CO. MP-320 DELAY OF GAME TIMER SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard
More informationI/O Expansion Box Installation & Operator s Instruction Manual
I/O Expansion Box Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More information4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.
More informationOPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES
PRICE: $25.00 LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES www.unipowertelecom.com Manual No. LVD-201-2 8/29/01/L46Man 2001 UNIPOWER Corp. All Rights Reserved UNIPOWER Telecom, Division of UNIPOWER
More informationPSA200 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationDVI ELR Extender over one CAT5
DVI ELR Extender over one CAT5 EXT-DVI-1CAT5-ELR User Manual Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use
More information700 Series 200 Amp Clamp Meters
700 Series 200 Amp Clamp Meters #61-700 #61-701 #61-702 1 2 3 6 5 7 4 8 1. Non-contact voltage (NCV) (#61-701 and #61-702) With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV
More informationOPERATING AND SERVICE MANUAL. Universal Interface Device 47
OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 202 SAFETY NOTICE Universal Interface Device 47 (UID47) connects two
More informationCMSA-100 Manual. Cinema Media Server Automation
CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.
More informationProgressive Industries, Inc. EMS Electrical Management System
Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.
More informationAudio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2
Audio DVI 3GSDI ELR Lite Embedder Extender over one CAT-5 EXT-DVI-1CAT5-SR User Manual Release A2 DVI ELR Lite Extender over one CAT-5 Important Safety Instructions 1. Read these instructions. 2. Keep
More informationE2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor
Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.
More informationUSB 2.0 CAT5E/6/7 EXTENDER
USER MANUAL IC402A-R2 USB 2.0 CAT5E/6/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM + + + + Mode Config Power Link Host Activity Power Link Host Activity TABLE OF CONTENTS PRODUCT OPERATION AND STORAGE... 3
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More informationBMS BULK METERING SYSTEMS INSTALLATION GUIDE. PAGE 1 KrausGroup Inc. Bulk Metering Systems Installation Guide (236AY00.PRG R001)
BMS TM BULK METERING SYSTEMS INSTALLATION GUIDE PAGE 1 KrausGroup Inc. Bulk Metering Systems Installation Guide (236AY00.PRG R001) 1998 Kraus Group Inc., Publication Number 236AY00.INS R00 BMS is a registered
More informationUÊ, Ê* - 1 Ê Ê Ê " /",Ê
Instruction Manual VDV Distance Meter VDV501-089 ENGLISH Español pg. 6 Français pg. 12 User RG-6 Cat3 RG-11 Cat5e RG-59 Cat6 Short ft m Voltage! pf/ READY www.kleintools.com ENGLISH VDV Distance Meter
More informationDVI ELR Extender over one CAT5
DVI ELR Extender over one CAT5 EXT-DVI-1CAT5-ELR User Manual Release A3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.
More informationIrrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0
Installation & User Guide Model 8ZEXT V1.0 2010 DuWa Products LLC PN1370-04 Table of Contents Introduction... 1 Overview... 2 Installation Instructions... 3 Installation Options... 3 Installing the Encoder...
More informationSP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan
SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier User Manual Made in Taiwan Safety and Notice The SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier has been tested for conformance to safety
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationINSTALLATION INSTRUCTIONS
www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous
More informationOZONE SWITCH Model OS-6. OS-6 Features
USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.
More information1-36V, 0-3A DC Power Supply
1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,
More informationVIP-480AL IP One-Way Horn
Issue 1 VIP-480AL IP One-Way Horn Issue 1 INTRODUCTION The VIP-480AL IP One-way Horn provides for one-way communication when used in a Valcom VoIP based intercom/paging system. SPECIFICATIONS Access Methods
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More information4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More informationSCD96 DMX Output Interface. Installation guide
SCD96 DMX Output Interface Installation guide Contents Introduction 2 Welcome 2 Dimensions 2 Specification 2 Safety 3 Please read this first 3 Mounting 4 Location and spacing 4 Ambient atmosphere requirements
More informationPRO REMOTE 25 LV CAPACITANCE PROBE
Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4
More informationDebitek Card Revalue Station Installation Manual
Page 1 of 5 Debitek Card Revalue Station Installation Manual General Description The Debitek Card Revalue Station family includes the Cash to Card, Cash to Card with Dispenser, Automatic Debit Machine,
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationHDMI Extender over Cat5e/6
Statement Thanks for purchasing this product, please read this user manual carefully before using this product.in the constant effort to improve our product, we reserve the right to make functions or parameters
More informationAcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter
AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment
More informationSeries 803 LED Product Price Display
Series 803 LED Product Price Display May 2007 Rev. 1.1 1 Installation and Operation Manual Table of contents 1. Safety.......3 2. Series 803 sign features.......4 2.1 Sign descriptions........4 2.2 Control
More informationINSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationUSB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by
USB Ranger 2212 Cat 5 USB 2.0 Extender with Remote Power User Guide Powered by Thank you for purchasing the USB Ranger 2212. Please read this guide thoroughly. This document applies to Part Numbers: 00-00252,
More informationDual Link DVI Extender
2x Dual Link DVI Extender EXT-2DVI-CATDL User Manual Release A4 2x Dual Link DVI Extender Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4.
More informationQUASAR Installation & Maintenance Guide motorized actuator for windows and skylights
Functional Fenestration Inc (FFI) Quasar Actuator Application Options On Wall or Frame Awning Skylight Hopper Concealed in Frame or Curtain Wall CAD files available on request from FFI. Optional brackets
More informationOilCop Component Wiring Installation Manual
OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:
More informationAudio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2
Audio DVI 3GSDI ELR Lite Embedder Extender over one CAT-5 EXT-DVI-1CAT5-SR User Manual Release A2 DVI ELR Lite Extender over one CAT-5 Important Safety Instructions 1. Read these instructions. 2. Keep
More informationOptions. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001
NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O
More informationUser's Guide. Model High Precision Quad Output DC Power Supply
User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications
More informationPanel Installation Datasheet
ACTIONPAC LNS5 & SAFEGARD V5 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product
More informationMini USB-2 Extender EXT-USB-MINI2N USER MANUAL
Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL Congratulations on your purchase of the Mini USB-2 Extender. Your complete satisfaction is very important to us. Gefen Gefen delivers innovative, progressive
More informationAEXX-349 SERIES REMOTE DISPLAYS
FN:349MAN1.DOC AEXX-349 SERIES REMOTE DISPLAYS DESCRIPTION AEXX-349 Series Remote Displays are available with 1, 2.3, 4, 8, or 12 high digits, visible from 5 feet to 500 feet away. They are available in
More informationINSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationMini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM
Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability
More informationEMS Electrical Management System
EMS Electrical Management System Complete Installation/Operating & Warranty Guide EMS-HW50C Rated at 240 Volts/50 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationINSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationHUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)
HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...
More informationINSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES
INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More information