User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

Size: px
Start display at page:

Download "User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction"

Transcription

1 User's Guide 1/16 th DIN ph Controller Model 48PH2 Introduction Thank you for selecting the Extech Model 48PH2 controller. This 1/16 th DIN-size controller offers dual display, high resolution measurements, two limit relays, and automatic temperature compensation. Careful use of this controller will provide years of reliable service.

2 Specifications ph measurement range Temperature Compensation Limit Relays (2) Hysteresis (deadband) Display resolution Measurement accuracy Display Relay status indicators Memory Back-up 0.01 to 14.00pH Automatic compensation (0-100 o C) via RTD temperature sensor or Manual compensation SPDT contacts rated for 5A (resistive) Adjustable from ph ph: 0.01pH; Temperature: 0.1 o ph: ± (0.02pH); Temperature: ±0.5 o C 3-1/2 Digit (2000 count) Dual LED (ph: red; Temperature: green) Front panel LED indication All programming and calibration data is saved while the meter is off Automatic calibration Automatic recognition of ph 7.00, 4.00, 10.00, 1.68 and Operating conditions Power supply Panel Cutout Meter Dimensions Meter Weight 32 to 140 o F (0 to 60 o C); 0 to 95% Relative Humidity 90 to 260VAC 50/60Hz 1/16th DIN 1.81 x 1.81" (46 x 46mm) 4.7 x 1.77 x 1.77" (105 x 45 x 45mm) 5 oz. (142g) 2

3 Front Panel Description 1. Unit of measure for top ph measurement display 2. Unit of measure for temperature display on lower digits 3. High Output Relay status LED indicator light is on when high relay is energized 4. CAL programming button 5. Upper display for ph measurement and programming displays 6. Lower display for temperature measurements and programming displays 7. Low Output Relay status LED indicator light is on when low relay is energized 8. SET programming button 9. UP arrow programming button 10. DOWN arrow programming button 3

4 Installation Mounting the Controller 1. Prepare a 1.81 x 1.81" (46 x 46 mm) panel cutout (1/8" to 3/8" thickness). 2. Slide the controller into the cutout until the bezel is flush with the panel. 3. Slide the mounting bracket over the rear of the controller and press snugly against the rear of the panel. R T D Rear View VAC 50/60 Hz ph Input Rear Panel Connections 1. Connect AC power to the terminals indicated in NO NC C NO NC C the diagram at right. LOW LIMIT HIGH LIMIT 2. Connect an RTD sensor to the terminals indicated in the diagram at right. Note that the supplied 110Ω resistor can be connected in place of an RTD to simulate 25 o C solution temperature. 3. Connect the ph electrode to the controller s BNC ph electrode input. If the ph electrode is not connected to the controller, the ph display will be all dashes. 4. Connect external devices to the HIGH and LOW Relay terminals. The SPDT (single pole double throw) relays are dry contact type and the terminal designations are: C = Common N.O. = Normally Open (contacts close when a controller setpoint is exceeded) N.C. = Normally Closed (contacts open when a controller setpoint is exceeded) Important Wiring Notes Controller wiring must be performed by qualified technicians knowledgeable of national, state, and local electrical codes and protection requirements. Improper wiring will result in meter damage and poses a risk to other equipment. For best service life, only light duty resistive circuits (1A or less) should be connected to the controller s relays. For higher current devices use a secondary relay between the controller relay and the external device. Coils are inductive loads and can cause arcing of the relay contacts. Employ a suitable snubber network (resistor/capacitor circuit) across the controller s relay terminals to prevent inductive spikes from damaging the relay contacts. The snubber component values must match the external coil for proper operation. 4

5 Output Relays The 48PH2 limit relays are typically used to control pumps to add acids and bases to a process in order to maintain a desired ph level. Limit relays can also be used as general alarm switches to activate a light or buzzer, for example, when a limit has been reached. Refer to the wiring instructions earlier in this manual for connection information. The output relays are switches. The Normally Open (N.O.) relay is an open switch whose contacts close when its associated setpoint value is exceeded. The Normally Closed relay is a closed switch whose contacts open when its associated setpoint value is exceeded. HIGH and LOW Relay Setpoints Relays switch state when their user-programmable setpoint is exceeded. They switch again when the limit is no longer exceeded. If the measurement exceeds the high setpoint, the high relay will switch state. If the measurement is lower than the low setpoint, the low relay will switch state. The programming steps are detailed later in this section. HIGH and LOW Deadband (Hysteresis) The Deadband feature is used to minimize relay chatter (rapid on/off relay switching) near setpoint. This is accomplished by creating a region where no relay action can occur (see diagram below). The High Deadband parameter (db.1) creates a band at the high setpoint and the Low Deadband parameter (db.2) creates a band at the low setpoint. RELAY ACTION DIAGRAM Notes on Relay Action Diagram In the area between the High Setpoint and the Low Setpoint, the labels on the relay contacts reflect the true status of the relays (Normally Open contacts are open and Normally Closed contacts are closed). No relay action can occur in the adjustable deadband regions. When the ph goes above the High Setpoint the High Relay contacts change state (Normally Open contacts close and Normally Closed contacts open). When the ph falls back below the High Setpoint, the contacts switch back (N.O. are open and N.C. are closed). When the ph goes below the Low Setpoint the Low Relay contacts change state (Normally Open contacts close and Normally Closed contacts open). When the ph goes back above the Low Setpoint, the contacts switch back (N.O. are open and N.C. are closed). 5

6 Programming the Setpoints and the Deadband 1. Press and hold the SET button until the display shows I_HI (High Setpoint). The display will then automatically cycle through 3 more displays: db.1 (High Deadband), 2_LO (Low Setpoint), and db.2 (Low Deadband). 2. Press the SET button when the desired parameter is on the display. For example, to adjust the Low Setpoint, press the SET button when the display is showing I_LO. 3. When the desired parameter has been selected, the top display will show the value to be adjusted. The bottom display will now show the parameter (I_LO, I_HI, etc.). 4. Use the UP and DOWN arrow buttons to adjust the SETPOINT or the DEADBAND. Selection ranges are shown in the table below. 5. Press the SET button when finished to store the new settings. 6. The table below shows the adjustment range for each of the parameters: High Setpoint (I_HI) High Deadband (db.1) Low Setpoint (2_LO) Low Deadband (db.2) Range 0.0 to 14.00pH 0.00 to 2.00pH 0.0 to 14.00pH 0.00 to 2.00pH Auto and Manual Temperature Compensation Automatic Temperature Compensation The 48PH2 measures solution temperature via a platinum 100Ω RTD sensor. As long as the RTD sensor is connected to the controller and placed in the solution under test, the controller will automatically compensate for changes in ph due to temperature changes. IMPORTANT NOTE: Before using the controller for the first time and each time the RTD sensor is replaced, the following procedure must be performed. 1. Press and hold the CAL button until the CAL display icon appears on the lower display. Within 2 seconds, press the CAL button again. 2. The display icon Pt will appear on the lower display. The upper display will flash. 3. Use the UP and DOWN arrow buttons to set a temperature on the upper display. The value entered must be equal to the difference between the actual temperature and the temperature reading. For example, if the actual temperature is manually measured to be 30 o C and the reading is 25 o C, the user would enter +5.0 o C in the controller. Note that the range of temperature that can be entered is ±10 o C. 4. After the correct value is entered, press the CAL button to exit this mode and return to the normal operating mode. Manual Temperature Compensation If neither an RTD sensor nor a simulator resistor is connected to the controller, the controller s temperature reading will be 25 o C. Use the UP and DOWN arrow buttons to set the actual temperature of the solution to be measured (the range of adjustment is ±10 o C). Use an external thermometer (mercury type, for example) to determine the solution temperature. 6

7 ph Calibration The 48PH2 has automatic buffer recognition technology. Frequent 2-point calibration should be performed first at ph7 and then at ph4 or PH 10, where the second point is near the ph values to be measured. Follow these steps to calibrate the 48PH2: 1. Place the ph electrode in a ph 7 buffer solution and wait for a stable ph reading. 2. Press and hold the CAL button for 2 seconds. The lower display will indicate CAL and the upper display will begin to flash the buffer ph value. 3. Wait for the controller to automatically exit the CAL mode. The display will stop flashing and the temperature value will appear on the lower display when the CAL mode has been successfully exited. 4. Rinse the electrode and then immerse it in a ph 1.68, 4.0, 10.0, or buffer solution and wait for a stable reading (select the buffer solution that best matches the measurement that will be taken after the calibration). 5. Repeat steps 2, 3, and 4 for the second calibration buffer. 6. Calibration is complete and the controller is now in the normal measurement mode. Special note for the calibration of non-standard buffers: If the buffer solution used is not ph 1.68, 4.00, 7.00, 10.00, or 12.45, the controller can be manually adjusted to accommodate the non-standard solution. Follow these steps: 1. Press and hold the CAL button until the lower display indicates CAL. Release the button before the display begins to flash. 2. When the digits begin flashing, use the DOWN and UP arrows to adjust the upper display to match the non-standard solution value. 3. After adjusting the display to match the solution, allow the controller to automatically switch back to the normal operating mode. In the normal operating mode the lower display digits read temperature. 7

8 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) ext. 210 for authorization or visit our website at (click on Contact Extech and go to Service Department to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification on most products or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to ensure calibration integrity. Support Hotline (781) Tech support: Ext. 200; support@extech.com Repair/Returns: Ext. 210; repair@extech.com Website: Copyright 2004 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 8

Mini Photo Tachometer Model Mini Contact Tachometer Model

Mini Photo Tachometer Model Mini Contact Tachometer Model User's Guide Mini Photo Tachometer Model 461700 Mini Contact Tachometer Model 461750 Introduction Congratulations on your purchase of the Extech Tachometer. The Model 461700 Photo Tachometer uses precision

More information

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

User's Manual. Model Heavy Duty Datalogging Module with Windows Software User's Manual Model 380340 Heavy Duty Datalogging Module with Windows Software Stores data for later recall and analysis Can be used with any Extech Heavy Duty meter Selectable recording interval Battery

More information

User's Manual Sound Level Alert Model SL130

User's Manual Sound Level Alert Model SL130 User's Manual Sound Level Alert Model SL130 Meets ANSI and IEC Type 2 Sound Level Meter Standards Settable High Limit with large bright High/Low indication and Alarm Output Wall or Desk mountable Extra

More information

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,

More information

Heavy Duty Datalogger Module

Heavy Duty Datalogger Module User's Guide Heavy Duty Datalogger Module Model 380340 Introduction Congratulations on your purchase of Extech s 380340 Datalogger Module. The Datalogger connects to and records data from Extech Heavy

More information

Laser Photo/ Contact Tachometer. m/min. ft/min

Laser Photo/ Contact Tachometer. m/min. ft/min User's Manual Model 461995 Laser Photo / Contact Tachometer Laser Photo/ Contact Tachometer 461995 MEMORY rpm PHOTO CONTACT ft/min m/min Introduction Congratulations on your purchase of Extech's Laser

More information

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Phase Sequence and Motor Rotation Tester Model User's Guide Phase Sequence and Motor Rotation Tester Model 480403 Introduction Congratulations on your purchase of the Extech Model 408403 Motor and Phase Rotation Indicator. This handheld instrument

More information

User's Guide. Digital Sound Level Meter. Model

User's Guide. Digital Sound Level Meter. Model User's Guide Digital Sound Level Meter Model 407730 Introduction Congratulations on your purchase of the Extech 407730 Digital Sound Level Meter. The 407730 measures and displays sound pressure levels

More information

4801P ph/orp controller

4801P ph/orp controller 4801P ph/orp controller Introduction: Thank you for choosing this ph/orp controller. This 1/16 DIN controller offers dual backlight LCD display, high accuracy, LED indicators, two control relays, and automatic

More information

User's Guide. Temperature / Humidity Datalogger. Model 42270

User's Guide. Temperature / Humidity Datalogger. Model 42270 User's Guide Temperature / Humidity Datalogger Model 42270 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment

More information

User s Manual. Model and Sound Level Calibrators

User s Manual. Model and Sound Level Calibrators User s Manual Model 407744 and 407766 Sound Level Calibrators Introduction Congratulations on your purchase of Extech s Sound Level Calibrator. Extech Calibrators accommodate Sound Level Meters with 0.5

More information

True RMS AC Voltage/Current Datalogger

True RMS AC Voltage/Current Datalogger User's Guide True RMS AC Voltage/Current Datalogger Model DL150 Introduction Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can monitor and log data over long

More information

Heavy Duty Datalogger Module

Heavy Duty Datalogger Module User's Guide Heavy Duty Datalogger Module Model 380340 Introduction Congratulations on your purchase of Extech s 380340 Datalogger Module. The Datalogger connects to and records data from Extech Heavy

More information

User's Guide. Datalogging Light Meter with PC Interface. Model

User's Guide. Datalogging Light Meter with PC Interface. Model User's Guide Datalogging Light Meter with PC Interface Model 401036 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date

More information

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero

More information

User's Guide. Model Laser Photo Tachometer

User's Guide. Model Laser Photo Tachometer User's Guide Model 461920 Laser Photo Tachometer Introduction Congratulations on your purchase of Extech's Mini Laser Photo Tachometer, Model 461920. This Tachometer provides non-contact RPM and Revolution

More information

User Guide. Moisture Meter. Model MO250

User Guide. Moisture Meter. Model MO250 User Guide Moisture Meter Model MO250 Introduction Congratulations on your purchase of the Extech MO250 Moisture Meter. The MO250 detects moisture in wood and other building materials such as brick, wall

More information

Digital Vane Thermo-Anemometer Model

Digital Vane Thermo-Anemometer Model User's Guide Digital Vane Thermo-Anemometer Model 451104 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment

More information

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP 0 User Guide ExStik TM Model RE300 Waterproof ORP Meter Patent Pending 500 MV 1000 TM RE300 ORP ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE button 4. CAL

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

User's Guide. Heavy Duty Differential Pressure Manometer. Model

User's Guide. Heavy Duty Differential Pressure Manometer. Model User's Guide Heavy Duty Differential Pressure Manometer Model 407910 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date

More information

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

User's Guide. Hot Wire Thermo-Anemometer Model Introduction User's Guide Hot Wire Thermo-Anemometer Model 407123 Introduction Congratulations on your purchase of the Extech Hot Wire Anemometer. This meter measures air flow and temperature by placing the sensor

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

User's Guide. Model High Precision Quad Output DC Power Supply

User's Guide. Model High Precision Quad Output DC Power Supply User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented User's Guide 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your

More information

3-Axis G-Force Datalogger

3-Axis G-Force Datalogger User's Guide 3-Axis G-Force Datalogger Model VB300 Introduction Congratulations on your purchase of the VB300 G-Force Datalogger. The Model VB300 can measure and record shock and vibration (acceleration)

More information

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Cup Thermo-Anemometer. Model AN400 User's Guide Cup Thermo-Anemometer Model AN400 Introduction Congratulations on your purchase of the Extech Cup Thermo-Anemometer. The AN400 measures air velocity in five units of measure: feet per minute

More information

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model User's Guide Heavy Duty Vane Thermo-Anemometer Model 407112 407112 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date

More information

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction User's Guide Vane Thermo-Anemometer Datalogger Model 451126 Introduction Congratulations on your purchase of Extech's Thermo-Anemometer Datalogger. This Vane-type Anemometer can indicate Air Velocity in

More information

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750 User Guide Heavy Duty Differential Pressure Manometer Model HD750 Warranty EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for three

More information

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt

More information

Integrating Sound Level Datalogger Model

Integrating Sound Level Datalogger Model User's Guide Integrating Sound Level Datalogger Model 407780 Introduction Congratulations on your purchase of the Extech 407780 Integrating Sound Level Meter. The 407780 with programmable integrating time

More information

Heavy Duty Mini Vane CFM Thermo Anemometer

Heavy Duty Mini Vane CFM Thermo Anemometer User's Manual Heavy Duty Mini Vane CFM Thermo Anemometer Model 407117 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for three years from

More information

Heavy Duty Datalogging Light Meter

Heavy Duty Datalogging Light Meter User's Guide Heavy Duty Datalogging Light Meter with PC Interface Model HD450 Introduction Congratulations on your purchase of the Extech HD450 Digital Light Meter. The HD450 measures illuminance in Lux

More information

User's Guide. Video Borescope. Model BR100

User's Guide. Video Borescope. Model BR100 User's Guide Video Borescope Model BR100 Introduction Congratulations on your purchase of this Extech BR100 Video Borescope. This instrument was designed for use as an inspection device. It can be used

More information

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 Introduction Congratulations on your purchase of Extech Instrument

More information

User Guide. ExStik FL700. Fluoride Meter

User Guide. ExStik FL700. Fluoride Meter User Guide ExStik FL700 Fluoride Meter Introduction The model FL700 is a system specifically designed for the quick and accurate measurement of fluoride ions in drinking water and other aqueous samples.

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

Heavy Duty Psychrometer + IR Thermometer Model HD500

Heavy Duty Psychrometer + IR Thermometer Model HD500 User Guide Heavy Duty Psychrometer + IR Thermometer Model HD500 Introduction Congratulations on your purchase of the Extech HD500 Psychrometer. This handheld meter measures and displays Air Temperature,

More information

SuperHeat Psychrometer Models RH350 and RH355 (kit)

SuperHeat Psychrometer Models RH350 and RH355 (kit) User's Guide SuperHeat Psychrometer Models RH350 and RH355 (kit) Introduction Congratulations on your purchase of the Extech RH350 SuperHeat Psychrometer. This device measures Differential Temperature

More information

Heavy Duty Vibration Meter

Heavy Duty Vibration Meter User Guide Heavy Duty Vibration Meter Model 407860 Introduction Congratulations on your purchase of the Extech 407860 Vibration Meter. The Model 407860 measures vibration levels in industrial machinery.

More information

User's Guide. Hot Wire Thermo-Anemometer Model

User's Guide. Hot Wire Thermo-Anemometer Model User's Guide Hot Wire Thermo-Anemometer Model 407123 Introduction Congratulations on your purchase of the Extech Hot Wire Anemometer. This instrument measures air flow and temperature by placing the sensor

More information

User's Manual. Digital Sound Level Meter. Model

User's Manual. Digital Sound Level Meter. Model User's Manual Digital Sound Level Meter Model 407768 Introduction Congratulations on your purchase of the Extech 407768 Sound Level Meter. This Auto Range Sound Level Meter meets ANSI and IEC Type II accuracy

More information

User's Guide Video Borescope Model BR200

User's Guide Video Borescope Model BR200 User's Guide Video Borescope Model BR200 Introduction Congratulations on your purchase of this Extech BR200 Video Borescope. This instrument was designed for use as a remote inspection device. It can be

More information

Heavy Duty CFM Thermo-Anemometer Model

Heavy Duty CFM Thermo-Anemometer Model User's Guide Heavy Duty CFM Thermo-Anemometer Model 407113 3 Introduction Congratulations on your purchase of the Extech 407113 CFM meter. This handheld meter can display Air Flow (CFM) with Area or Air

More information

Digital Sound Level Meter

Digital Sound Level Meter User's Guide Digital Sound Level Meter Model 407732 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com information. A Return Authorization

More information

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction

User's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction User's Guide Power Analyzer Model 380801 Power Analyzer Datalogger Model 380803 Introduction Congratulations on your purchase of the Extech 380801 or 380803 Power Analyzer Datalogger. This device offers

More information

User's Guide. Vibration Meter and Laser Combination Tachometer Model

User's Guide. Vibration Meter and Laser Combination Tachometer Model User's Guide Vibration Meter and Laser Combination Tachometer Model 461880 Introduction Congratulations on your purchase of the Extech 461880 Vibration Meter and Combination Laser Tachometer. The 461880

More information

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

Oyster Meter ph-conductivity-tds-salinity-orp(mv) User's Guide Oyster Meter ph-conductivity-tds-salinity-orp(mv) Model 341350A INTRODUCTION Congratulations on your purchase of the Extech's Oyster Series meter. This device measures ph, Conductivity, TDS,

More information

Hygro Thermo-Anemometer Model

Hygro Thermo-Anemometer Model User's Manual Hygro Thermo-Anemometer Model 407412 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

User's Guide. Model Noise Dosimeter with PC Interface. Introduction User's Guide Noise Dosimeter with PC Interface Model 407355 Introduction Congratulations on your purchase of the Extech 407355 Personal Noise Dosimeter. The 407355 is designed to test noise exposure in

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company Operating Instructions Cole-Parmer ph/orp 400 ph/orp Controller Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:

More information

User's Guide. Mini Microscope. Model MC108

User's Guide. Mini Microscope. Model MC108 User's Guide Mini Microscope Model MC108 Introduction Congratulations on your purchase of this Extech Meter. This digital microscope with 7 to 27X optical magnification, 4X digital zoom, image capture

More information

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller Operation Manual TX10 1/8 DIN Microcomputer Based /ORP Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING THE Sensorex

More information

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2 User s Guide Dual Input, 3-Display Thermometer/Datalogger Model 421509 Accepts J, K, T, E, R, S, & N thermocouples Internal Memory stores up to 16 data sets, with 1024 maximum data capacity Backlit Electro-luminescent

More information

Power Analyzer Datalogger Model

Power Analyzer Datalogger Model User's Guide Power Analyzer Model 380801 Power Analyzer Datalogger Model 380803 Extech 380803 Appliance Tester/Power Analyzer Extech 380803 True RMS Power Analyzer Data Logger Extech 380803-NIST True RMS

More information

Dual Input, 3-Display Thermometer/Datalogger Model

Dual Input, 3-Display Thermometer/Datalogger Model USER GUIDE Dual Input, 3-Display Thermometer/Datalogger Model 421509 Accepts J, K, T, E, R, S, & N thermocouples Internal Memory stores up to 16 data sets, with 1024 maximum data capacity Backlit Electro-luminescent

More information

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM.   For latest product manuals: User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info TXDIN1700 Universal DIN Rail omega.com info@omega.com U.S.A. Headquarters: Servicing North

More information

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Autoranging Multimeter plus IR Thermometer Extech 450 Patented User's Guide Autoranging Multimeter plus IR Thermometer Extech 450 Patented Introduction Congratulations on your purchase of the Extech 450 (part number EX450) Autoranging Multimeter plus IR Thermometer.

More information

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax: OPERATION MANUAL /ORP 300 (Cat. No. 0580212) MICROCOMPUTER BASED /ORP/ Temperature CONTROLLER 625 East Bunker CT, Vernon Hills, IL 60061-1844 Phone: 800-32-4340, Fax: 847-247-2929 E-mail: info@coleparmer.com,

More information

TX ph/mv Transmitter/Controller

TX ph/mv Transmitter/Controller TX3000 - ph/mv Transmitter/Controller PRODUCT INSTRUCTION MANUAL TX3000 ph/mv Transmitter ESSENTIAL INSTRUCTIONS READ THIS BEFE USING YOUR TX3000 ph/mv TRANSMITTER! Thank you for choosing the TX3000 ph/mv

More information

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company Operating Instructions Cole-Parmer ph/orp 350 ph/orp Transmitter Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 PRODUCT NAME: 3101 Conductivity Controller - 1 - Global Water s Conductivity

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending User's Guide True RMS Multimeter plus IR Thermometer Extech 470 Patent Pending Introduction Congratulations on your purchase of the Extech 470 (part number EX470) True RMS Autoranging Multimeter plus IR

More information

Operation Manual MODEL 3621 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Controller MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual MODEL 3621 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Controller MANUFACTURER OF PRECISION INSTRUMENTS Operation Manual MODEL 3621 Microcomputer Based ph/orp Controller JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS CONTENTS GENERALINTRODUCTION)))))))))))))))..)))...2 INITIALINSPECTION))...))))))...2

More information

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430 Operation Manual INDEX 1 Specifications 2 Assembly and installation 2.1 Precautions for installation 2.2 Installation of controller

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

Operations Manual EcoSense ph100

Operations Manual EcoSense ph100 Operations Manual EcoSense ph100 Portable ph, mv and Temperature Instrument English Français Español Deutsch Italiano WARRANTY The EcoSense ph100 Instrument is warranted for one year from date of purchase

More information

TELEDYNE HASTINGS INSTRUMENTS

TELEDYNE HASTINGS INSTRUMENTS TELEDYNE HASTINGS INSTRUMENTS INSTRUCTION MANUAL MASS FLOWMETER CONTROLLER READOUT POWERPOD-100 Manual Print History The print history shown below lists the printing dates of all revisions and addenda

More information

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810 Operation Manual Hand-held ph/mv/temperature Meter ph6810 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3

More information

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION The DFI 7000 Signal Conditioner-Indicator is a complete 4-1/2-digit signal conditioner and indicator housed in a 1/8 DIN case. This unit provides

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter Operation Manual MODEL ph6175 Microcomputer Based ph/orp/temperature Benchtop Meter ph6175 0 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 POWER INPUT.......2 INSTALLING THE BATTERIES.....3

More information

Autoranging Mini Multimeter Model MN16A

Autoranging Mini Multimeter Model MN16A User's Guide Autoranging Mini Multimeter Model MN16A Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,

More information

LCI Load Cell Junction Box with Fault Monitor

LCI Load Cell Junction Box with Fault Monitor LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1

More information

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

Microprocessor ph/orp Controller

Microprocessor ph/orp Controller PC3030A/PC-3050 Microprocessor ph/orp Controller Operating Manual CONTENTS 1 Specifications... 2 Assembly and installation... 2.1 Precautions for installation.. 2.2 Install the controller on the wall mount

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English User Manual DOCUMENT #601119REF EcoSense ph1000a ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL English Item #601119REF Rev C, October 2017 For the latest version of this manual, visit ysi.com

More information

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1 POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.

More information

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2 POWER SERIES Plus 3 in 1 AC Voltage Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful

More information

Temperature & Humidity Datalogger

Temperature & Humidity Datalogger R6030 Temperature & Humidity Datalogger Instruction Manual Table of Contents Introduction... 2 Product Quality... 3 Safety... 3 Features... 3 Included... 3 Specifications... 4 Instrument Description...

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

4-20/10-50 ma/v Loop Calibrator

4-20/10-50 ma/v Loop Calibrator Model 535 4-20/10-50 ma/v Loop Calibrator Practical Instrument Electronics Operating Instructions Basic Keypad Operations j EZ-Check Switch/EZ-Step Pushbutton Slide the switch to select the user stored

More information

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer

User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer User's Guide Extech EX840 True RMS 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX840 CAT IV True RMS 1000A Clamp Meter. This meter measures

More information

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A.

NOTE: The F2 button and the 4 LED annunciators do not function on the LD-ACF-I. To use these features, ask about the LD-ACF-R4/R4A. Large display AC frequency indicator The is a sophisticated microprocessorbased indicator designed specifically to monitor AC frequency. Intuitive scrolling text menus, (activated from the front panel),

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information