1 1 Manual and application description 4 channel 0-10V dimmer V2.0

2 2 1. Device description 1.1 General 0-10V dimmer is used for proportional control of 4 electronic ballasts with 1-10 V signal. There are also three binary inputs for manual push button control. Note! There are ballasts on the market with 0-10V control; additional contactor should be installed in this case to switch the ballast fully off. 1.2 Range of application Module is used for control of electronic ballasts with 1-10V signal. E.g. by sending 1% value, output gives 1 V, 100% - 10 V. 1.3 Installation The device is designed for DIN-rail mounting; it s tiny and requires only 1 DIN-unit of mounting space. 1.4 Features 4 separate 0-10V channel dimming 3 x binary inputs for optional manual control via push buttons Recognition of the last state of each channel Feedback of the switching state and brightness value 15 various preprogrammed scenes with defined brightness values, more available through Logic Machine with transition time SOFT on, SOFT off timer Status object shows of output LOCK binary object allows blocking all manual input controls Powered over KNX/EIB bus Compact design 1.5 Default settings To reset the device to default settings, press and hold programming button for more than 10 seconds. Programming LED will blink several times after releasing the programming button. The device will restart automatically after the reset is complete. 1.6 Terminals Outputs and KNX/EIB bus wires are connected using CAGE CLAMP mounting system. Push button A 1 4 Channel A 0-10V Dimmer Push button B Channel B 2 5 Push button C Channel C 3 6 Programming LED Programming button KNX/EIB 7 Channel D 8 GND

3 3 1.7 Technical data Power supply Channels Inputs Connections Supply voltage Voltage margin 29 VDC by KNX bus VDC Number 4 Output type 0-10 V analog PWM frequency 1.5 khz Number 3 Input type push button KNX/EIB Inputs /Outputs CAGE CLAMP mounting system CAGE CLAMP mounting system Operating and display Programming LED For assigning the physical address elements Programming button For assigning the physical address Type of protection IP20 In accordance with DIN EN Temperature range Physical Certification Operation Storage -5 C 45 C -25 C 55 C Design DIN rail mounted device for installation on 35mm mounting rail Housing / Color Polyamide / Grey Dimensions 15 x 91 x 56 mm (W x H x D) Weight 0,1 kg CE, RoHS In accordance with EMC and low-voltage guidelines Certificate

4 4 2. Application description 2.1 Default state of the device Factory-new devices have the physical address , no group addresses. 2.2 ETS configuration Channel configuration All four channels have identical settings. On object behavior object behavior on on state use previous or preset brightness Brightness preset [1..100] preset brightness level Soft on timer (seconds) [0..15] soft start timer Soft off timer (seconds) [0..15] soft stop timer Soft transition (seconds) [0..15] soft transition timer if used with scene settings keep time (seconds) [ ] time to play the scene transition time (seconds) [0..16] transition time between scenes

5 s settings Number of scenes to use [1..15] number of scenes parameters All scenes have identical settings. [0..100%] channel A brightness level [0..100%] channel B brightness level Channel C [0..100%] channel C brightness level Channel D [0..100%] channel D brightness level Manual push button control There are three binary inputs built in the device allowing manually control first three 0-10 V channels.

6 Object description

7 7 Object Name Type Comm. Read Write Transmit Comments Channel C Channel D Channel C Channel D Out: On/off Out: On/off Channel C Out: On/off Channel D Out: On/off Channel C Channel D number step random keep time transition time Manual input lock (5.001 scaling) In: Number (1..15) In: Up/down In: Seconds ( ) 7.* 2-Byte Unsigned In: Seconds (0..16) Random scenes in Time to play for specific scene Transition time between scenes Lock manual input Technical support Any faulty devices should be returned to Embedded Systems. If there are any further technical questions concerning the product, please, contact our support, available Mon-Fri 9:00 17:00 GMT 02:00. Please write to support@genohm.eu or call Firmware updates are available at

Manual and application description KNX/EIB LED driver V2.0

Manual and application description KNX/EIB LED driver V2.0 1 Manual and application description KNX/EIB LED driver V2.0 2 1. Device description 1.1 General KNX/EIB LED allows dimming one RGB LED strip as well as 3 standard LED lamps. There are also three binary

More information

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001 SK 0012 B 98 The control unit is a DIN rail mounted device for insertion in the distribution board. It is used to control digitally dimmable electronic ballast devices or transformers via the EIB. In a

More information

Line Coupler, MDRC LK/S 2.1, GH Q R0001

Line Coupler, MDRC LK/S 2.1, GH Q R0001 , GH Q605 0019 R0001 The coupler can be used as a line In the distribution board the coupler is coupler or as an area coupler. Used as installed on the secondary line of the a line coupler it joins up

More information

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111 , GH Q631 0021 R0111 The 4-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal. Using four floating contacts,

More information

CANx / LoRa 433 MHz 8 x Analog inputs / Digital ouputs

CANx / LoRa 433 MHz 8 x Analog inputs / Digital ouputs Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com CANx / LoRa 433 MHz 8 x Analog inputs / Digital ouputs

More information

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111 , GH Q631 0028 R0111 The 4-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal. It is particularly suited

More information

IntesisBox BACnet/IP Server DALI

IntesisBox BACnet/IP Server DALI IntesisBox BACnet/IP Server - DALI Gateway for integration of DALI ballasts into BACnet/IP networks BACnet IP client BACnet/IP Ethernet DALI bus BACnet IP client LAN TCP/IP IntesisBox DALI ballasts LinkBoxBacnet

More information

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111 , GH Q31 0022 R0111 The 2-fold shutter actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal. It is used to control two

More information

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

4 CHANNEL UNIVERSAL DIMMING ACTUATOR 4 CHANNEL UNIVERSAL DIMMING ACTUATOR USER MANUAL Tel.: 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com General Description - 4 Channel universal modular dimming actuator for leading and trailing edge

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. , GH Q631 0047 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. Using eight floating contacts, it switches

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016 Use of the application program Product family: Product type: Manufacturer: Application: Name: Description: Order no: Application: Name: Description: Order no: Lighting Dimmer Siemens Switch-/Dimming Actuator

More information

Installation and User Guide

Installation and User Guide D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect

More information

LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to

LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com LogicMachine5 LogicMachine (LM) is your easiest way

More information

Push Button Interface UP 220D31

Push Button Interface UP 220D31 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall

More information

EAE KNX Switch Actuator

EAE KNX Switch Actuator EAE KNX Switch Actuator Order Number: 48002 Content 1 General... 2 2 Device Technology... 3 2.1 Connection Diagram... 3 2.2 Technical Data... 4 3 Communication Object Table... 5 4 Parameters... 6 4.1 Main

More information

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in prom design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation

More information

Control4 DIN Rail Lighting

Control4 DIN Rail Lighting Control4 DIN Rail Lighting Life s Better When Everything Works Together Want to change the moods and atmosphere in each room of the house? Using conventional lights, energy saving lights, LEDs and want

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Application description for the KNXnet/IP Interface Web

Application description for the KNXnet/IP Interface Web Contents 1. General 1. General... 1 1.1 Basic information about the KNX/EIB BUS... 1 1.2 Application versions......1 1.3 Symbols...1 1.4 Function description... 2 1.5 Short description of the function

More information

LogicMachine5 Power (LM5p-DW1)

LogicMachine5 Power (LM5p-DW1) Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com LogicMachine5 Power (LM5p-DW1) LogicMachine (LM) is

More information

Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX

Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX Email: info@knx-taster.de Internet: www.knx-taster.de Order code: Basic element KNX4 Order code: Plaster compensation

More information

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/ Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Dimming Actuators User manual-ver. 4 KA/D 0103.1 KA/D 0203.1 KA/D 0403.1 KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/03.1...... KNX/EIB Intelligent

More information

DMX2DALI. Setup Manual. e:cue lighting control An OSRAM Company Rev

DMX2DALI. Setup Manual.  e:cue lighting control An OSRAM Company Rev Setup Manual www.ecue.com e:cue lighting control An OSRAM Company Rev. 20101104 For a most recent version of this manual please visit: http://www.ecue.com/download 2 Contents Device Overview 4 About DMX2DALI

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

IntesisBox KNX - BACnet/IP Client

IntesisBox KNX - BACnet/IP Client IntesisBox KNX - BACnet/IP Client Gateway for integration of BACnet/IP devices into KNX control systems. Integrate Daikin VRV Air Conditioners into your KNX system. Daikin VRV system must be equipped with

More information

application software

application software application software application software RF input product Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices 8565 52 xx 8565 62

More information

DALI RGBW LED Dimmer CV

DALI RGBW LED Dimmer CV RGBW LED Dimmer CV Datasheet Control Gear RGBW LED Dimmer (CV, DT8) Art. Nr. 86458509 (8A) Art. Nr. 89453840 (10A) Art. Nr. 89453843 (16A) Art. Nr. 89453843-HS (16A, dinrail) 2018-08-27, Lunatone Industrielle

More information

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via

More information

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011 Technical Data 2CDC504091D0201 ABB i-bus KNX Product description The Weather Unit WZ/S 1.3.1.2 is used - primarily in residential applications - to record weather data. The Weather Sensor WES/A 3.1 is

More information

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology   Page 1/10 General Description Room Control Unit RCU Series are designed as an all in one product for different room layouts such as apartments, hotel rooms, hospitals and residences. Available versions of EAE RCU

More information

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011 Technical Data 2CDC505168D0201 ABB i-bus KNX Product description The Analogue Actuator converts telegrams received via KNX into analog output signals. The device has four outputs. The analog outputs can

More information

PX175. DMX-DALI Converter MANUAL

PX175. DMX-DALI Converter MANUAL PX175 DMX-DALI Converter MANUAL CONTENTS 1. General description... 1 2. Safety conditions... 1 3. Connections and control elements description... 2 4. Programming the device... 4.1. Navigating the menu...

More information

PRODUCT MANUAL LUZEN PLUS. Universal Dimmer ZN1DI-P400. Program version: 3.0 Manual edition: a

PRODUCT MANUAL LUZEN PLUS. Universal Dimmer ZN1DI-P400. Program version: 3.0 Manual edition: a PRODUCT MANUAL LUZEN PLUS Universal Dimmer ZN1DI-P400 Program version: 3.0 Manual edition: a INDEX Document updates... 3 1. Introduction... 4 1.1. LUZEN PLUS... 4 1.2. Types of load... 5 1.3. Installation...

More information

Gateways DMXBUS-K 2 GW Programming manual

Gateways DMXBUS-K 2 GW Programming manual Gateways DMXBUS-K 2 GW612110 Programming manual Index 1 GENERAL DESCRIPTION... 3 2 TECHNICAL INFORMATION... 3 3 PROGRAMMING... 5 3.1 APPLICATION PROGRAM INFORMATION... 5 3.2 INDIVIDUAL ADDRESS... 5 3.3

More information

IntesisBox KNX - AIRZONE

IntesisBox KNX - AIRZONE IntesisBox KNX - AIRZONE Gateway for the integration of Airzone InnoBUS into KNX systems. Full integration of Airzone InnoBUS air conditioning with KNX control systems. CS CS KNX EIB Bus IntesisBox RS485

More information

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

DLD1248 BUS single channel PRO. Device Manual FW 1.0 FEATURES

DLD1248 BUS single channel PRO. Device Manual FW 1.0 FEATURES pag. 1/16 FEATURES Output: 1 x channel BUS+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DMX512+RDM, DALI, MODBUS LOCAL Command: N.O. push button (with or without memory), 0-10V, 1-10V, Potentiometer

More information

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server - BACnet/IP Client IntesisBox Modbus Server - BACnet/IP Client Gateway for integration of devices into Modbus (RTU and TCP) systems. Integrate Daikin VRV Air Conditioners into your Modbus system (SCADA, BMS, PLC ). For this,

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

IP gateway, MDRC IG/S 1.1, GH Q R0001

IP gateway, MDRC IG/S 1.1, GH Q R0001 , GH Q631 0067 R0001 The IP gateway IG/S is the interface The IP address of the IG/S can be between EIB / KNX installations and IP fixed or received from a DHCP server. CDC 071 130 F0003 networks. Data

More information

Rotary Measurement Technology Absolute Encoders, Singleturn

Rotary Measurement Technology Absolute Encoders, Singleturn -20 to 85 C High rotational speed Temperature Shock/ vibration resistant Short-circuit proof Reverse polarity protection Rugged Highest shock resistance on the market: ( 200 g (2,500 m/s 2 )), 6 ms acc.

More information

Operating Instructions. DALI-Gateway

Operating Instructions. DALI-Gateway Operating Instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Failure to observe the instructions may cause damage to the device and result

More information

MA /2015. User manual CU-DIN DRY 4-Z KNX EC

MA /2015. User manual CU-DIN DRY 4-Z KNX EC MA00652800 06/2015 User manual CU-DIN DRY 4-Z KNX EC10430381 TABLE OF CONTENTS 1 Description...3 2 Safety instructions...4 3 Product function...4 4 Hardware...5 4.1 Technical data... 5 4.2 Dimensional

More information

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Push Button Sensor User manual-ver. 1.1 CHKP-01/01.1.xx CHKP-02/01.1.xx CHKP-03/01.1.xx KNX/EIB Intelligent Installation Systems GVS K-BUS R

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

DLB1248 single channel EASY-BLE

DLB1248 single channel EASY-BLE pag. /0 FEATURES BLUETOOTH+FADER+DIMMER+DRIVER DC Input: 2-24-48 Vdc Remote command options: - Bluetooth Low Energy (BLE/Smart) Local command options: - Normally Open push-button Adjusting the brightness

More information

Binary Inputs, 4 fold K-BUS R. User manual-ver. 1 CTBI-04/00.1. KNX/EIB Intelligent Installation Systems

Binary Inputs, 4 fold K-BUS R. User manual-ver. 1 CTBI-04/00.1. KNX/EIB Intelligent Installation Systems Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Binary Inputs, 4 fold User manual-ver. 1 CTBI-04/00.1 KNX/EIB Intelligent Installation Systems Contents 1. General-----------------------------------------------------------------------------------------------------------------

More information

DLX1224 multi channel BLE

DLX1224 multi channel BLE pag. 1/8 FEATURES BLUETOOTH+SEQUENCER+FADER+DIMMER+DRIVER DC Input 12-24 Vdc RF Command: Bluetooth low energy Local Command: Push Buttons Control: Dimmer, Tunable White, RGB or RGBW Color Current outputs

More information

Operation and installation manual KNX IO 511 (1O2I) Application. 1. Installation and Connection

Operation and installation manual KNX IO 511 (1O2I) Application. 1. Installation and Connection EN Operation and installation manual KNX IO 511 (1O2I) (Art. # 5232) Switching actuator with 1 output and 2 binary inputs A. KNX Programming mode The KNX programming mode is activated/deactivated either

More information

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com DALI RS485 gateway ENG - Data sheet Issue date 8.02.2013

More information

eelecta & new products

eelecta & new products eelecta & new products Home and Building Evolution Eelectron - Via Magenta 77/22, I-20017 Rho (MI), Italy Eric Ducros eric.ducros@eelectron.com +39 02.9316681 www.eelectron.com info@eelectron.com www.eelectron.com

More information

Datasheet - SLB 200-C04-1R

Datasheet - SLB 200-C04-1R 14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety

More information

RS485/ KNX Bidirectional Converter K-BUS R. User manual-ver.1.3 BTPT-02/ KNX/EIB Intelligent Installation System

RS485/ KNX Bidirectional Converter K-BUS R. User manual-ver.1.3 BTPT-02/ KNX/EIB Intelligent Installation System Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R RS485/ KNX Bidirectional Converter User manual-ver.1.3 BTPT-02/485.1 KNX/EIB Intelligent Installation System Contents 1. Summary--------------------------------------------------------------------------------------------------------------------------3

More information

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com DALI RS485 gateway ENG - Data sheet Issue date 8.02.2013

More information

IntesisBox LON - KNX

IntesisBox LON - KNX IntesisBox - KNX Gateway for the integration of KNX devices into LonWorks networks KNX interface Bindings interface FB_1 Com.Obj1 nvo1 KNX (TP-1) KNX Com.Obj2 Netwo nvon nvi1 nvin (TP/FT-10) Com.ObjN FB_N

More information

KNX DALI Gateway Plus - User Manual

KNX DALI Gateway Plus - User Manual KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64

More information

The output variables can be force-controlled from a coordinating control system.

The output variables can be force-controlled from a coordinating control system. Produktname: 4-channel analog actuator Bauform: rail-mounted device Artikel-Nr.: 1022 00 ETS-Suchpfad: Gira Giersiepen / Output / Analog output 4fach / Analog actuator 4fach Scope of application: The analog

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions DIN RAIL ELECTRONIC FAN SPEED Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions Control unit, 1-10 V 3-gang Order-No. : 1019 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the

More information

Contatto. ModDALI. DUEMMEGI s.r.l. - Via Longhena, MILANO Tel. 02/ Fax 02/ Rel.: 2.3 June 2017 Page 1 of 8

Contatto. ModDALI. DUEMMEGI s.r.l. - Via Longhena, MILANO Tel. 02/ Fax 02/ Rel.: 2.3 June 2017 Page 1 of 8 : 4-channel gateway module allows the management, through the bus, of 4 lines upon it's possible to connect up to 32 devices for line (or channel). In this way it's possible to control and regulate up

More information

PG AB Notifier NFS 3030 to Modbus RTU Protocol Converter

PG AB Notifier NFS 3030 to Modbus RTU Protocol Converter PG-141-100-AB Notifier NFS 3030 to Modbus RTU Protocol Converter PG-141-100-AB is highly powerful, superior, completely configurable and productive Building & Industrial Automation gateway for integrators

More information

EIB/KNX ENO Radio bus interface (32-channel)

EIB/KNX ENO Radio bus interface (32-channel) EIB/KNX ENO Radio bus interface (32-channel) Interface between EnOcean and EIB/KNX, on-wall mounting (Quelle: EIBMARKT GmbH, Reference No.: N000406) Page 1 Application EIB/KNX ENO Radio bus interface acts

More information

DIN RAIL 12/8/4 OUTPUT MODULE. BOxxB01KNX. Product Handbook

DIN RAIL 12/8/4 OUTPUT MODULE. BOxxB01KNX. Product Handbook DIN RAIL 12/8/4 OUTPUT MODULE BOxxB01KNX Product Handbook Product: BOxxB01KNX -BO12B01KNX -BO08B01KNX -BO04B01KNX Description: DIN RAIL 12/8/4 OUTPUT MODULE Document Version: 1.2 Date: 07/07/2015 1/16

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

Datasheet liniled Dim 4-DALI-PRO

Datasheet liniled Dim 4-DALI-PRO Manufacturer s declaration that the product meets the applicable EC directives. Datasheet liniled Dim 4-DALI-PRO USP s Index Professional grade LED driver Single colour, Tunable White, RGB and RGBW modes

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

HDL KNX / EIB-BUS HDL KNX / EIB BUS M/HS05.1. (Intelligent Installation Systems) Product Manual. Contents

HDL KNX / EIB-BUS HDL KNX / EIB BUS M/HS05.1. (Intelligent Installation Systems) Product Manual. Contents HDL KNX / EIB-BUS (Intelligent Installation Systems) Product Manual Contents 1-General... 3 1.1-Product Function... 3 2- Hardware... 4 2.1 Technical data... 4 2.2 Dimension drawings... 6 2.3 Wiring diagram...

More information

Dimmers - Clipsal by Schneider Electric

Dimmers - Clipsal by Schneider Electric 13/12/2017 Dimmers - Clipsal by Schneider Electric Dimmers Intelligent and comprehensive dimming solutions for a wide variety of control requirements. The ranges available share an innovative modular design

More information

SMART DRIVER SDV-480. User Manual. Please read the instructions carefully before use

SMART DRIVER SDV-480. User Manual. Please read the instructions carefully before use SMART DRIVER SDV-480 User Manual Please read the instructions carefully before use 1B 1. Safety Introductions Please read the User Manual carefully as it includes important information regarding details

More information

DLM Single Channel BUS Device Manual EASY-BUS FW 1.2

DLM Single Channel BUS Device Manual EASY-BUS FW 1.2 Device Manual EASY- FW 1.2 pag. 1/11 NEW MENU PUSH FEATURES +FADER+DIMMER+DRIVER DC input: DC 12-24-48 Vdc or 12-24Vdc Command: - DALI - DMX512+RDM MULTI Analogic Automatic Detection of the Local Command:

More information

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line Product Overview 5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line Description The new Gigabit Ethernet industrial switch offers the full Gigabit performance on all ports. This offers, beside

More information

Engineered for Best Fixture Performance. Product features. 5 year warranty. Certificates and standards. Classifications. Dimming L1M1MLT105S-20E

Engineered for Best Fixture Performance. Product features. 5 year warranty. Certificates and standards. Classifications. Dimming L1M1MLT105S-20E L05011i LED Driver 20W, 3 33Vdc, 350-1050mA L1M1MLT105S-20E Engineered for Best Fixture Performance Fulham LumoSeries drivers are all built on core engineering design principles for exceptional standards

More information

The LED display (1) turns green when the load is switched on.

The LED display (1) turns green when the load is switched on. Order no.: 2365 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems. IntesisBox Server - M-Bus (EN 13757-3) Gateway for the integration of M-BUS meters with and based control systems. Integrate M-Bus meters into your master device or system (BMS, SCADA, PLC, HMI, TouchPanels

More information

DALI RGBW LED Dimmer CV

DALI RGBW LED Dimmer CV DALI RGBW LED Dimmer CV Datasheet Control Gear RGBW LED Dimmer (CV, DT8) Art. Nr. 86458509 (8A) Art. Nr. 89453840 (10A) Art. Nr. 89453843 (16A) Art. Nr. 89453843-HS (16A, dinrail) 2018/02/20, Lunatone

More information

SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION

SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION MODEL TYPE NO. SG HOKUSPOKUS KNX/KLR 25010 Program version 2.7 2012 M. Züblin AG Neue Winterthurerstrasse 30, 8304 Wallisellen, Switzerland The

More information

Product and Application Description

Product and Application Description Technical Product-Information Product and Application Description The IP Gateway KNX-BACnet N 143 is is a DIN rail mounted device connecting a KNX installation with a system using BACnet/IP communication.

More information

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description (-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

EAE KNX Room Control Unit Product Manual RCUXXYY

EAE KNX Room Control Unit Product Manual RCUXXYY EAE KNX Room Control Unit Product Manual RCUXXYY RCU2018 RCU2016 RCU1212 RCU0808 RCU2000 RCU2000 RCU1200 RCU0800 Note: RCUXXYY where XX denotes the number of outputs and YY number of inputs. Index 1 General...

More information

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011 Technical Data 2CDC504084D0201 ABB i-bus KNX Product description The device is used to record analogue data. Four conventional sensors can be connected to the device. The connection to the bus is established

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

DALI 3Ch LED Dimmer CV

DALI 3Ch LED Dimmer CV 3Ch LED Dimmer CV Datasheet Control Gear 3-channel LED Dimmer (CV, DT6) Art. Nr. 89453828 (4A) Art. Nr. 89453834 (8A) Art. Nr. 86459571 (10A) Art. Nr. 89453831 (16A) 3Ch LED Dimmer CV DT6 2 3Ch LED Dimmer

More information

LogicMachine5 Reactor IO V2

LogicMachine5 Reactor IO V2 Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com LogicMachine5 Reactor IO V2 LogicMachine (LM) is your

More information

Stand Alone 512 channels DIN-DMX Interface

Stand Alone 512 channels DIN-DMX Interface Stand Alone 512 channels DIN-DMX Interface V1.0.1 Summary Technical features of the interface P.02 General pinout and device's connector P.02 Interfaces Master/Slave connections P.03 Triggers configuration

More information

Din Rail 8 Input / 8 Output Module

Din Rail 8 Input / 8 Output Module Din Rail 8 Input / 8 Output Module IO88B02KNX Product Handbook Product: Din Rail 8 Input / 8 Output Module Order Code: IO88B02KNX 1/32 INDEX 1. General Introduction... 3 2. Product and functional overview...

More information

Rotary Position Technology Absolute Encoders, Singleturn

Rotary Position Technology Absolute Encoders, Singleturn -20 to 85 C High rotational speed Temperature Shock/vibration resistant Short-circuit proof Reverse polarity protection Optical sensor Magnetic field proof Rugged Highest shock resistance on the market:

More information

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011 Technical data 2CDC507101D0202 ABB i-bus KNX Product description The ABB i-bus KNX DALI Light Controller DLR/S 8.16.1M is a KNX modular installation device (MDRC) in ProM design for installation in the

More information

DALI 2Ch LED Dimmer CV

DALI 2Ch LED Dimmer CV 2Ch LED Dimmer CV Datasheet Control Gear 2-channel LED Dimmer (CV, DT6) Art.Nr. 89453827 (4A) Art.Nr. 89453833 (8A) Art.Nr. 86459561 (10A) Art.Nr. 89453830 (16A) 2Ch LED Dimmer CV DT6 2 2Ch LED-Dimmer

More information

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track Electronic multiturn gear with intelligent sensing technology (IST) Integrative Technology Max. 4 programmable outputs* for the SSI version Programmable parameters include*: code type, resolution per revolution,

More information

Operating voltage Maximum

Operating voltage Maximum , 2CDG 110 0x R0011 2CDC 071 023 F000 The ABB i-bus Light Controllers, (x = 2 or 4) are KNX modular installation devices in ProM Design for installation in the distribution board on 35 mm mounting rails.

More information

IntesisBox ASCII Server - KNX

IntesisBox ASCII Server - KNX IntesisBox ASCII Server - KNX Gateway for integration of KNX / EIB systems into ASCII enabled control systems. Integrate KNX based lighting/blind control systems into your ASCII enabled control system

More information

K-BUS Binary Inputs. User manual-ver. 1

K-BUS Binary Inputs. User manual-ver. 1 Guangzhou Video-Star Eletronnics Co.,Ltd. K-BUS Binary Inputs User manual-ver. 1 CHBI-04/00.1 Intelligent Installation Systems http://www.video-star.com.cn Contents 1. General -------------------------------------------------------------------------------------------------------------------------

More information