Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Size: px
Start display at page:

Download "Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems"

Transcription

1 Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use.

2 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, can result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury. Caution, used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, can result in property damage or improper operation. NOTE: Provides additional information to clarify or simplify a procedure Schneider Electric. All Rights Reserved.

3 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin PLEASE NOTE Class B FCC Statement Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. This document is not intended as an instruction manual for untrained persons. No responsibility is assumed by Square D for any consequences arising out of the use of this manual. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help Schneider Electric. All Rights Reserved. 3

4 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 INTRODUCTION The Clipsal Two Channel (SLC5102BCLEDL) and the Four Channel (SLC5104BCL) Bus Coupler units are key input devices that allow voltage free mechanical switches, such as reed, pressure, micro or other switches, to be connected to the C-Bus Network. They transmit messages to output devices to control load states and provide all C-Bus switching commands, including: on, off, toggle, timer and dimming functions, etc. The Bus Couplers are designed to fit into typical wall boxes along with voltage free mechanical switches. The Two Channel (SLC5102BCLEDL) Bus Coupler units may be wired to external LED to indicate the state of operation. The Four Channel (SLC5104BCL) Bus Coupler has built-in LED indicators on the front of the unit to indicate the state of operation. The Learn Mode feature is also incorporated in these units, allowing a quick and easy way to program mechanical switches, to achieve various control functions such as: on/off, dimmer or timer. A spring return type switch, such as a momentary contact switch, is recommended for dimming operations. Before Your Begin Before installing the Two Channel and Four Channel Bus Couplers, verify that your order is complete by comparing the contents of the package with the appropriate list in the table below. Also verify that the catalog number on the box label matches your order. Table 1: Contents of the Box Part Number Description Quantity SLC5102BCLEDL Two Channel Bus Coupler 1 SLC5104BCL Four Channel Bus Coupler Bootlace Terminals 1 bag (for C-Bus wiring connections) Schneider Electric. All Rights Reserved.

5 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin SAFETY PRECAUTIONS This section contains important safety precautions that must be followed before attempting to install or maintain electrical equipment. Carefully read and follow the safety precautions below. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. This equipment must be installed and serviced by qualified electrical personnel. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. Failure to follow these instructions will result in death or serious injury Schneider Electric. All Rights Reserved. 5

6 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 Megger Testing Do not Megger test C-Bus data cabling or terminals. Megger testing of data cabling or terminals can degrade the performance of the C-Bus network. HAZARD OF C-BUS NETWORK PERFORMANCE DEGRADATION Do not Megger test C-Bus data cabling or terminals as it can degrade the performance of the C-Bus network. Failure to follow this instruction will result in damage to the C-Bus network. Transient Voltage Surge Protection Use this unit only within the limits of the design specifications. Each unit incorporates transient protection circuitry. Additional external power surge protection devices should be used to enhance system immunity to power surges. It is strongly recommended that appropriate transient voltage surge protection be installed at all service equipment Schneider Electric. All Rights Reserved.

7 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin INSTALLATION Network Considerations Follow the procedures in this section to properly install Two Channel and Four Channel Bus Couplers. Before installing the Bus Couplers, verify that wall boxes will accommodate both the switches and the Bus Couplers. The Bus Couplers draw 18 ma from the C-Bus network. Verify that an adequate number of C-Bus Power Supply Units are installed on the C-Bus Network to support the connected devices. Configuration Options The installer can program the unit in two ways: Using a personal computer Using Learn Mode. Whichever method is used, each Bus Coupler must be assigned a unique unit address. A group address must be assigned for each channel on all bus coupler units. When the units are being installed as part of a large or complex network, it is most efficient to perform the basic configuration before the units are physically installed. However, the units can be configured before or after physical installation. Configuring with a Personal Computer The following components are typically required to configure a Bus Coupler (specific items and product numbers can vary according to the C-Bus unit and network). PC with the C-Bus Toolkit software installed Bus Coupler Unit (SLC5102BCLEDL or SLC5104BCL) C-Bus PC Interface (SLC5500PC) or C-Bus Ethernet gateway (SLC5500CN) 2008 Schneider Electric. All Rights Reserved. 7

8 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 Configuring without a Personal Computer using Learn Mode The Bus Coupler is a C-Bus Input unit that allows users to set the relationships between Output Units and the Input Unit without a computer. Note: Each output unit which is to be associated with the Bus Coupler in this way must be a C-Bus unit as well. Learn Mode provides a quick and simple way to program the C-Bus Input units to provide basic functions. To program the Bus Coupler using Learn Mode to turn on loads, connect each channel of the Bus Coupler to a conventional switch. Then do the following for each channel: 1. Enter Learn Mode by holding down a local override button on a C-Bus output unit for 10 seconds. The Unit and C-Bus indicators will begin to flash alternately. 2. Select the local override buttons on the output unit associated with the loads you want to control. The selected indicators will illuminate. 3. Place the (non C-Bus) switch you want to associate with the selected load in the ON position. The light on the Bus Coupler associated with this switch will light. 4. Exit Learn Mode by pressing any local override button on an output unit for 2 seconds. Identifying the C-Bus Units and Their Locations The location of each C-Bus unit must be tracked. Two recommended methods are given below, one for when the units are configured before installation (see section Labeling the C-Bus Units ), the other for when the units are configured after installation (see section Recording Each Unit s Location ). Labeling the C-Bus Units When C-Bus units are configured before physical installation, it is important to label them to indicate where they are to be placed. One method for doing this would be to write each unit s address directly on it. NOTE: Verify that each configured unit has been marked to indicate where it should be placed in an enclosure or a building or site Schneider Electric. All Rights Reserved.

9 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin Recording Each Unit's Location In order to track C-Bus units that will be configured after physical installation, they must be identified and their location must be recorded at the time they are installed. NOTE: If a unit has already been configured and assigned a location on a site map, it is not necessary to make another record of its location. HAZARD OF UNEXPECTED OR IMPROPER SYSTEM BEHAVIOR Properly record the physical location of each unit using the liftand-peel label provided on the box and a site plan or location log. Retain location records and provide them to the person(s) responsible for configuring and commissioning the network. Failure to follow these instructions can result in unexpected or improper system behavior. Before installing a unit, use the following guidelines to record its location. Recording each unit's location is required for configuration with the C-Bus Toolkit software. Each unit is identified by a unique serial number found on the box label (see the figure Box Label with Lift-and-Peel Section ). The serial number provides important information for recording a unit's location. Figure 1: Box Label with Lift-and-Peel Section KEY: A. Serial number B. Bar code C. Lift-and-peel section 2008 Schneider Electric. All Rights Reserved. 9

10 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 The box label also has a bar code that can be read by an infrared scanner and used for a record of a specific unit s location. A liftand-peel section of the box label duplicates the box label s information (see Box Label with Lift-and-Peel Section diagram). To record the location of a unit, remove the lift-and-peel section from the box label and attach it to a site plan or other document. The lift-and-peel section now provides a record of the physical location where that unit is installed. When installing multiple units of one kind in an area or enclosure, such as six four-channel DIN dimmers in an enclosure, verify that the document or site plan indicates the relative position of each specific unit. Connecting Bus Couplers to the C-Bus Network Installation requires connection to the unshielded twisted pair C-Bus Network cable. Use a Category 5 data cable. Use the insulated bootlace terminals provided. Tighten the C-Bus Network terminal screws securely. The recommended torque for tightening terminal screws is 12 lb-inch (1.4 Nm). Do not exceed this torque. NOTE: The C-Bus network connection is polarity sensitive. The polarity is clearly marked on the front of the unit One loop-in removable terminal block is provided for easy wiring installation and maintenance. Figure 2: C-Bus Terminal Block, Front View KEY: A. Terminal block connectors (front view) B. Neutral (-) terminal (orange/white - blue/white wires) C. Positive (+) terminal (blueorange wires) D. Bootlace terminal NOTE: The recommended torque for tightening terminal screws is 12 lb-inch (1.4 Nm). Do not exceed this torque value Schneider Electric. All Rights Reserved.

11 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin Table 2: Category 5 Data Cable Connections RJ Pin C-Bus Connection Color 1 Remote ON* Green/White 2 Remote ON* Green 3 C-Bus Neg (-) Orange/White 4 C-Bus Pos (+) Blue 5 C-Bus Neg (-) Blue/White 6 C-Bus Pos (+) Orange 7 Remote OFF* Brown/White 8 Remote OFF* Brown *Not used Figure 3: C-Bus Wiring Connections KEY: A. C-Bus positive (+): blue + orange B. C-Bus negative (-): blue/white + orange/white C. Remote OFF: brown + brown/white D. Remote ON: green + green/white HAZARD OF C-BUS NETWORK PERFORMANCE DEGRADATION Do not Megger test C-Bus data cabling or terminals as it can degrade the performance of the C-Bus network. Failure to follow this instruction will result in damage to the C-Bus network. Bus Couplers do not have Remote Override (On/Off) functions. However, correct connections must be maintained for these services across the C-Bus Network Schneider Electric. All Rights Reserved. 11

12 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 Connecting Bus Couplers to Remote Switches and LEDs The Two Channel Bus Couplers (SLC5102BCLEDL) with remote LED feedback and the Four Channel (SLC5104BCL) Bus Couplers enable the use of a wide range of conventional dry contact switch mechanisms to indirectly switch C-Bus loads. The Bus Couplers are designed to fit within the wall box behind switches. Verify that the wall box will accommodate both the switch and the Bus Coupler. A small length of wire is used to connect these switches to the input terminals of the Two or the Four Channel Bus Couplers or remote LEDs to the input terminals of the Two Channel Bus Couplers (the Four Channel Bus Couplers do not offer remote LED indication). Any type of appropriately rated insulated copper wire (solid or stranded) no greater than 12 AWG (3.1mm²) or less than 24 AWG (0.2mm²) may be used to connect between remote LEDs (SLC5102BCLEDL only), voltage free or dry contact switches or channel inputs (both SLC5102BCLEDL and SLC5104BCL). The maximum cable length is 39 in. (1m) per channel; however the total length of cable connecting the Bus Couplers to the remote switches in a single network should be kept to a maximum of 32.8 ft. (10m) to maintain communications across the C-Bus network. Example: 10 channels at 39 in. (1m) or 20 channels at in. (500mm). If longer connections are required for the Two Channel or Four Channel Bus Couplers it is recommended that you use a Square D Clipsal DIN Mounted Auxiliary Input (SLCLE5404AUX), which has input isolation. The Auxiliary Input Unit is specifically designed for that type of application. However, the Auxiliary Inputs do not offer remote LED indication. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Isolate switch input and LED connection wires from all other electrical power source wiring, electrical noise sources, and grounded metal structures. Do not enclose bus couplers in multigang style wall boxes with switches wired to external power sources. Failure to follow this instruction will result in death, serious injury, and damage to the C-Bus network Schneider Electric. All Rights Reserved.

13 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin When connecting remote LEDs, use only those with a minimum current rating of 10mA. Table 3: Wiring Terminal Descriptions Two Channel Bus Coupler (SLC5102BCLEDL) Four Channel Bus Coupler (SLC5104BCL) Wire Clip (Terminal) Description Wire Clip (Terminal) Description 1 Channel 1 input 1 Channel 1 input C Switched input (common*) C Switched input (common*) 2 Channel 2 input 2 Channel 2 input C Switched input (common*) C Switched input (common*) 1A LED 1 Anode (A) 3 Channel 3 input 1K LED 1 Cathode (K)** C Switched input (common*) 2A LED 2 Anode (A)** 4 Channel 4 input 2K LED 2 Cathode (K) C Switched input (common*) *The switched input "common" is internally connected to C-Bus negative (-). ** The 1K and 2A outputs are linked internally Schneider Electric. All Rights Reserved. 13

14 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 Making the Electrical Wiring Connections HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH This equipment must be installed and serviced by qualified electrical personnel. Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E. Turn off all electrical power supplying this equipment before working on or inside the equipment. Always use a properly rated voltage sensing device to confirm that power is off. Replace all devices, doors, and covers before turning on power to this equipment. The two and four channel inputs of the Bus Couplers are not isolated from the C-Bus network. Verify that all cables connected to the C-Bus network are well separated from the external electrical power source. Connect external switches to no other power source Failure to follow these instructions will result in death or serious injury. Follow the instructions below to connect the Two Channel and Four Channel Bus Couplers to the remote wall switch. Install Bus Couplers in accordance with the National Electrical Code and applicable local codes. Use copper wire only [#12 AWG - 24 AWG (0.2mm² - 3.1mm²)]. 1. Refer to the applicable wiring diagram to connect either Two Channel (SLC5102BCLEDL) or Four Channel Bus Couplers (SLC5104BCL) to the wall switch. 2. Use a #12 AWG - 24 AWG (0.2mm² - 3.1mm²) copper wire to make the electrical wiring connections. Remove.375 in. (9.52 mm) of the wire insulation. 3. Lift up on the spring-loaded wire clip on the Bus Coupler (see the diagram "Making the Electrical Wiring Connections") and insert the copper wire into the wire clip Schneider Electric. All Rights Reserved.

15 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin 4. Release the spring-loaded wire clip. Pull firmly on the wire to verify that the wire is secure. 5. Carefully place the Bus Coupler along with the electrical wires and C-Bus cables into the wall box. Push them gently toward the back of the wall box. 6. Mount the wall switch in the wall box. Figure 4: Making the Electrical Wiring Connections KEY: A. Spring-loaded wire clip B. Insert the wire [#12 AWG - 24 AWG (0.2mm² - 3.1mm²)] Wiring the Two Channel Bus Coupler (SLC5102BCLEDL) KEY: (A.) To C-Bus Network (B.) LED Anode/Cathode wiring (1.) Anode - A (+) (2.) Cathode - K (-) Follow the guidelines listed below Schneider Electric. All Rights Reserved. 15

16 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 Use only remote LEDs with a minimum current rating of 10mA The LED output connections must be made and maintained correctly for the unit to operate. Flashing LEDs are not compatible with this product Wiring the Four Channel Bus Coupler (SLC5104BCL) Figure 5: Wiring Diagram - SLC5104BCL Four Channel Bus Coupler KEY: (A.) To C-Bus Network (B.) Channel indicator Schneider Electric. All Rights Reserved.

17 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin Wiring a Shared Common A single shared common wire can be used to minimize the amount of wire. Follow the wiring diagram that applies to the bus coupler you are using. Figure 6: Common Neutral Wiring Schemes KEY: (1.) Two Channel Bus Coupler (2.) Four Channel Bus Coupler (A.) To C-Bus Network (B.) Switch connections (C.) LED indicators 2008 Schneider Electric. All Rights Reserved. 17

18 Clipsal Bus Couplers A2 Instruction Bulletin 11/2008 STANDARDS The Two Channel and Four Channel Bus Couplers complies with the following Standards: Table 4: U.S. and Canadian Product Safety Standards and U.S. FCC Regulations Standards/Regulations CSA C22.2 No. 205 Title Signal Equipment UL916 Energy Management Equipment FCC Part 15 Class B Digital Device for Home or Office Use SPECIFICATIONS Table 5: SLC5102BCLEDL Specifications Parameter Catalog Number C-Bus Supply Voltage Current Drain Voltage across Input when external switch opens Voltage across Input when external switch closes Switch closed current Max cabling distance Isolation between inputs Isolation between inputs and C-Bus Operating Temperature Operating Humidity Range Removable C-Bus Terminals Wire Size Channel Input/Output Side (Spring Loaded Terminals) Wire Size Weight Description SLC5102BCLEDL Two Channel Bus Coupler with Remote LED s 15-36V 18mA required for normal operation depending on LED output configuration (See table below for minimum operating voltages). Does not source current to the C-Bus Network. 18 ma 5V DC 0V DC Less than 50μA 10 channels at 39 in. (1m) or 20 channels at in. (500mm) Not isolated Not isolated F (0 45 C) 95% RH non-condensing Category 5 data cable (insulated) Appropriately rated insulated copper wire (solid or stranded) no greater than 12 AWG (3.1mm²) or less than 24 AWG (0.2mm²) 1.13 oz. (32g) Schneider Electric. All Rights Reserved.

19 A2 Clipsal Bus Couplers 11/2008 Instruction Bulletin Table 6: SLC5102BCLEDL Minimum C-Bus Operating Voltage Specifications LED Output Configuration Using two LEDs Using one LED and one link Using no LEDs and two links Minimum C-Bus Operating Voltage 15V + Sum of both LED forward voltages 15V + LED forward voltage 15V Table 7: SLC5104BCL Specifications Parameter Catalog Number C-Bus Supply Voltage Current Drain Voltage across Input when external switch opens Voltage across Input when external switch opens Switch closed current Max cabling distance Isolation between inputs Isolation between inputs and C-Bus Operating Temperature Operating Humidity Range Removable C-Bus Terminals Channel Input Side (Spring Loaded Terminals) Weight Description 5104BCL Four Channel Bus Coupler 15-36V 18mA required for normal operation. Does not source current to the C-Bus Network. 18 ma 5V DC 0V DC Less than 50μA 10 channels at 39 in. (1m) or 20 channels at in. (500mm) Not isolated Not isolated F (0 45 C) 95% RH non-condensing Category 5 data cable Appropriately rated insulated copper wire (solid or stranded) no greater than 12 AWG (3.1mm²) or less than 24 AWG (0.2mm²) 1.13 oz (32g) 2008 Schneider Electric. All Rights Reserved. 19

20 Clipsal Bus Couplers Instruction Bulletin Dimensions Figure 7: Unit Dimensions SUPPORT AND SERVICE Contact the Square D Customer Information Center for technical support by phone at Square D ( ) or at lightingcontrol.support@us.schneider-electric.com. Contact your local Square D service representative or Clipsal certified installer for repairs or service to your network. You may also find helpful information on our web site at Schneider Electric, USA 320 Tech Park Drive La Vergne, TN, SquareD ( ) Square D,, Clipsal, C-Bus, Saturn and Neo are trademarks or registered trademarks of Schneider Electric and/or its affiliates in the United States and/or other countries. Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material Schneider Electric. All Rights Reserved A2 11/2008

Square D Clipsal Pascal Automation Controller

Square D Clipsal Pascal Automation Controller Square D Clipsal Pascal Automation Controller SLC5500PACA For Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal Pascal Automation Controller 63249-420-258A2 Instruction

More information

Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR

Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR Wiser EER260LLCR Load Control Control de carga EER260LLCR Contrôle de charge EER260LLCR Installer s Guide / Guía de instalación / Guide de l'installateur S1A90300 Rev. 03, 08/2012 Retain for future use.

More information

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX Instruction Bulletin 63249-500-04A3 07/2010 Fiber Optic Switch Packs SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION SLSPSP101 Single Input Switch Pack SLSPSP102 Dual Input Switch Pack The

More information

C-Bus Eight and Twelve Channel Voltage Free Relay Installation Instructions

C-Bus Eight and Twelve Channel Voltage Free Relay Installation Instructions C-Bus Eight and Twelve Channel Voltage Free Relay Installation Instructions 55xxRVF Series REGISTERED PATENT 3042248 Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3

More information

5504 Thermocouple Analog Input Module

5504 Thermocouple Analog Input Module 550 Thermocouple Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

5 B&W Rear View System Camera

5 B&W Rear View System Camera 5 B&W Rear View System Camera Instruction Manual MODEL: CA453 www.lorexcctv.com Copyright 2007 LOREX Technology Inc. Thank you for purchasing the Lorex 5 Black & White Rear View System Camera. This system

More information

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT 4 10/100/1000T + 2 1000 Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch User Manual V1.0 September-2013 FCC Warning This Equipment has been tested and found to comply with

More information

MultiTech Router Commissioning for Com X 200/210/510

MultiTech Router Commissioning for Com X 200/210/510 Knowledge Base 7EN42-0166 05/2017 MultiTech Router Commissioning for Com X 200/210/510 This document describes installation recommendations and how to commission a MultiTech rcell Series router for use

More information

C-Bus 4 Channel Voltage Free Changeover Relay L5504RVFC. Series. Installation Instructions

C-Bus 4 Channel Voltage Free Changeover Relay L5504RVFC. Series. Installation Instructions C-Bus 4 Channel Voltage Free Changeover Relay L5504RVFC Series Installation Instructions C-Bus 4 Channel Voltage Free Changeover Relay Installation Instructions Contents 1.0 Product Range...3 2.0 Description...3

More information

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual 4-port 10/100TX + 1 or 2-port 100FX Industrial Switch User Manual Rev.1.03 Sep-2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

5401 and 5402 Digital I/O Modules

5401 and 5402 Digital I/O Modules 50 and 50 Digital I/O Modules Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216

More information

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Hypercable injecteur HPOE -  Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail : Industrial IEEE 802.3at Gigabit PoE Injector User Manual v.1.0 Jun-2011 FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

DALI Gateway 5502DAL. Installation Instructions

DALI Gateway 5502DAL. Installation Instructions DALI Gateway 5502DAL Installation Instructions Contents 1.0 Product Range...3 2.0 Description...3 3.0 Features...3 4.0 C-Bus Indicators...4 4.1 Unit/Comms Indicator...4 4.2 C-Bus Indicator...4 5.0 Wiring

More information

Wa r n i n g-wa r n i n g-wa r n i n g

Wa r n i n g-wa r n i n g-wa r n i n g Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment

More information

PowerLogic ION7300 Series

PowerLogic ION7300 Series PowerLogic ION7300 Series Power and Energy Meter Advanced Field Retrofit Instructions August 2006 Danger This symbol indicates the presence of dangerous voltage within and outside the product enclosure

More information

COMMERCIAL. VAM24-90-(A) Series Installation Instructions

COMMERCIAL. VAM24-90-(A) Series Installation Instructions MERCIAL VAM24-90-(A) Series Installation Instructions Bray Controls Commercial Division 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdivision.com

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual Lantech IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

More information

SCADAPack E 5405 Digital Input Hardware Manual

SCADAPack E 5405 Digital Input Hardware Manual SCADAPack E 5405 Digital Input Hardware Manual 2 SCADAPack E 5405 Digital Input Hardware Manual Table of Contents Part I 5405 Digital Input Module 3 1 Technical... Support 3 2 Safety... Information 4 3

More information

T775S Series 2000 Expansion Module

T775S Series 2000 Expansion Module T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone

More information

Introduction to C-Bus Toolkit Software C-Bus Products Training Course

Introduction to C-Bus Toolkit Software C-Bus Products Training Course Introduction to C-Bus Toolkit Software C-Bus Products Training Course Training Guide 1250SM0803R10/09 Retain for future use. Introduction to C-Bus Toolkit Software 1250SM0803R10/09 C-Bus Products Training

More information

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch User Manual (Hardware) Oct. 2018 Recommendation for Shielded network cables

More information

5521 Potentiometer Analog Input Module

5521 Potentiometer Analog Input Module 55 Potentiometer Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

PowerLogic ION7550 RTU option

PowerLogic ION7550 RTU option 70052-0213-02 PRODUCT OPTION 01/2011 PowerLogic ION7550 RTU option The PowerLogic ION7550 Remote Terminal Unit (RTU) option is designed for data acquisition from WAGES (water, air, gas, electricity, steam)

More information

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2 RF Home Automation ZRF113 Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2 Note: This module must be Included in the Network only where it will

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-12s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-12s 8-Relay expansion module is used with the X-600M controller. The X-12s has eight

More information

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-11s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-11s 2-relay expansion module is used in conjunction with the X-600M controller. The

More information

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input. LNP-0500-24 series 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input User Manual FCC Warning This Equipment has been tested and found to comply with

More information

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital

More information

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/ Symmetra PX 160 Maintenance Bypass Enclosure Installation 05/2014 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH) Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could

More information

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1 Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1 Warning: To reduce risk of injury, the user must read and understand this user manual before using the laser

More information

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual 6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the

More information

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual LNP-0602 series 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A

More information

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

C-Bus Two Channel Infrared Transmitter Unit Installation Instructions

C-Bus Two Channel Infrared Transmitter Unit Installation Instructions C-Bus Two Channel Infrared Transmitter Unit Installation Instructions 5034NIRT Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual 10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual v1.02 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 2260 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS, Copyright 2006. Black Box Corporation. All rights reserved 1000 Park Drive * Lawrence, PA. 35055-1018 * 724-746-5500 * Fax 724-746-0746 56-80830BB-00 Rev A1 June 2007 JUNE 2007 LGC320A, LGC321A, LGC322A,

More information

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter Lantech IGC-0101DSFP IPGC-0101DSFP 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter User Manual Dec 2016 Recommendation for Shielded network cables STP cables have additional shielding

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

0311 A OI GTW-LC SERVICE MANUAL. GT System Lift control adaptor GTW-LC INSTALLATION & OPERATION MANUAL

0311 A OI GTW-LC SERVICE MANUAL. GT System Lift control adaptor GTW-LC INSTALLATION & OPERATION MANUAL 03 A OI GT System Lift control adaptor SERVICE MANUAL INSTALLATION & OPERATION MANUAL CONTENTS PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.

More information

USER GUIDE. Smart Wi-Fi LED Bulb (2700K and 5000K) Model: W11-N11

USER GUIDE. Smart Wi-Fi LED Bulb (2700K and 5000K) Model: W11-N11 USER GUIDE Smart Wi-Fi LED Bulb (2700K and 5000K) Model: W11-N11 Model: W11-N11 Introduction: Sengled Wi-Fi Smart LED bulbs offer an easy solution to having smart lighting without the need for a hub. These

More information

C-Bus Four Channel Voltage Free Relay Installation Instructions

C-Bus Four Channel Voltage Free Relay Installation Instructions C-Bus Four Channel Voltage Free Relay Installation Instructions 5504RVF Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3

More information

IQ-SBS LCU Series Installation Instructions

IQ-SBS LCU Series Installation Instructions Installation Instructions LCU-1 The IQ-SBS LCU-1 is a self-contained device for integrating control of facility lighting with IQ-SBS. The LCU-1 controls lighting zones, accepts input from override switches

More information

SCADAPack E 5505 RTD Input Hardware Manual

SCADAPack E 5505 RTD Input Hardware Manual SCADAPack E 5505 RTD Input Hardware Manual 2 SCADAPack E 5505 RTD Input Hardware Manual Table of Contents Part I 5505 RTD Input Module 3 1 Technical... Support 3 2 Safety... Information 4 3 Overview...

More information

HD40H(X) Performance Series Camera. User Guide

HD40H(X) Performance Series Camera. User Guide HD31H(X) HD30H(X) HD40H(X) Performance Series Camera User Guide Document 1 2 HD40H(X)/HD30H(X)/HD31H(X) Camera User Guide Thank you for purchasing our product. If there are any questions, or requests,

More information

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual 8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual FCC Warning This Equipment has been tested and found to comply with the limits for a

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Adaptor Model No. CZ-CFUNC1U For your safety Read the following instructions carefully, and carry out secure installation and electrical work. The precautions given in this manual

More information

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product

More information

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual Lantech IPGS-0005T-4 4 10/100/1000T PoE at + 1 1000T Industrial Unmanaged Switch User Manual V1.00 Jan-2018 Content Overview... 1 Introduction... 1 Features / Model List... 2 Packing List... 3 Safety Precaution...

More information

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1. Hardened Ethernet to VDSL2 Extender User Guide Revision History Rev.1.03 Dec 2009 Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Document Release Date Revision Initials 1.00 Jun 04, 2009

More information

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Electrical network protection Sepam series 20 Sepam series 40 Quick start 03146790FE+01+NP00000000 Electrical network protection Sepam series 20 Sepam series 40 Quick start PE50465 Storage Sepam may be stored in its original packaging in a closed sheltered location: b ambient

More information

Installing the Enphase Envoy-S Metered

Installing the Enphase Envoy-S Metered QUK INSTALL GUIDE (Model ENV-S-AM1-120) Installing the Enphase Metered To install the Enphase Standard, read and follow all warnings and instructions in this Guide and in the Enphase Installation and Operation

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

Installing Powerlink NF3500G4 Controllers

Installing Powerlink NF3500G4 Controllers Installing Powerlink NF3500G4 Controllers for Use with Powerlink Systems RETAIN FOR FUTURE USE Installing Powerlink NF3500G4 Controllers 63249-420-374A3 Instruction Bulletin 09/2015 2 2015 Schneider Electric.

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

Instruction Bulletin

Instruction Bulletin Instruction Bulletin 63249-401-200/A4 03/2005 POWERLINK TM G3 Controller NF1000G3 for use with POWERLINK G3 Systems Retain for future use. NOTICE Read these instructions carefully and look at the equipment

More information

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0 170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch Lantech IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch IGS-0204DSFP 4 10/100/1000T + 2 Dual Speed SFP Industrial Unmanaged Switch User Manual V1.00 Jul-2016 Content

More information

Documentation on all Paxton products can be found on our web site -

Documentation on all Paxton products can be found on our web site - 08/20/2012 Ins-30019-US Net2 I/O board Paxton Technical Support 1.800.672.7298 Technical help is available: supportus@paxton-access.com Monday - Friday from 02:00 AM - 8:00 PM (EST) Documentation on all

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612 MONOPRICE Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter P/N 21612 User's Manual SAFETY WARNINGS AND GUIDELINES Please read this entire manual before using this device, paying extra attention to these safety

More information

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference. INSTRUCTION MANUAL DISTRIBUTION UNIT Please read this manual thoroughly before use, and keep it handy for future reference. ISSUE 1 May 2006 LIMITATION OF LIABILITY THE INFORMATION IN THIS PUBLICATION

More information

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A pool/spa control system IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller User s and Installation Guide P/N 520886 - Rev A *520886* i MobileTouch Wireless Controller kit contents The

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A AT-6102 IEEE 802.3af Universal Multi-voltage PoE Splitter Installation and User Guide PN 613-000635 Rev A Electrical Safety and Emissions Standards Standards: This product meets the following standards.

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Monochrome Camera. Features. User manual

Monochrome Camera. Features. User manual Monochrome Camera LTC0330/11 LTC0330/21 LTC0350/11 LTC0350/21 LTC0330/51 LTC0330/61 LTC0350/51 LTC0350/61 Features To obtain the best results from your new camera, read these instructions carefully before

More information

Installation Instructions

Installation Instructions Installation Instructions Cat. No. 1771 P3, P4, P5 and P5E Use this document as a guide when installing the catalog number 1771-P3, -P4, -P5 or -P5E power supplies. Because of the variety of uses for the

More information

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH FR-IB100/PCIe FlexRay PCI Express Interface Card USER MANUAL 4.01.0103.20000 2.0 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

R SERIES INSTALLATION GUIDE

R SERIES INSTALLATION GUIDE R SERIES INSTALLATION GUIDE Welcome to your smartest install yet. Things you should know Latch R is a proximity reader, keypad, and wireless entry system, that can be operated as a standalone device or

More information

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION The Solution Multi-Input Module INSTALLATION INSTRUCTIONS Model: MIM-62 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION MIM-62 connects up to 6 monitored entrapment protection

More information

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual Nature Power Inverters Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w Owner s Manual Modified Sinewave Series True Sinewave Series For safe and optimum performance, the Power Inverter must be

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation SIMATIC NET PG/PC - Industrial Ethernet Operating Instructions 1 Preface 2 Description of the device 3 Software installation 4 Hardware installation 5 Configuration 6 Technical specifications A Approvals

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT C-Bus Network Bridge 5500NB Series Installation Instructions REGISTERED DESIGN REGISTERED PATENT Contents 1.0 Description...3 1.1 Capabilities...3 1.2 Status Indicators...4 2.0 C-Bus Network Connections...5

More information

Installation Instructions RF5010 and RF5210

Installation Instructions RF5010 and RF5210 Installation Instructions RF5010 and RF5210 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards

More information

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

Wireless Fixture Adapter (WFA100-SN) Installation Instructions Installation Instructions The Daintree Wireless Fiture Adapter () forms part of Daintree s Controlscope Manager (CSM) in commercial and industrial buildings. It transmits and receives messages over the

More information

Daily use. indicating that the loud speakers

Daily use. indicating that the loud speakers BeoLab 8002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equipment to dripping or splashing and ensure that no objects

More information

Installing the Enphase IQ Commercial Envoy

Installing the Enphase IQ Commercial Envoy QUICK INSTALL GUIDE (Model ENV-IQ-AM3-3P) Installing the Enphase IQ Commercial Envoy To install the Enphase IQ Commercial Envoy, read and follow all warnings and instructions in this Guide and in the Enphase

More information