28-Position 23 Rack Mounting Model RM23-20X

Size: px
Start display at page:

Download "28-Position 23 Rack Mounting Model RM23-20X"

Transcription

1 Rev Position 23 Rack Mounting Model RM23-20X SECTION PAGE # 1. GENERAL APPLICATIONS INSTALLATION TESTING CUSTOMER SERVICES WARRANTY AND REPAIRS SPECIFICATIONS ORDERING INFORMATION GENERAL 1.1 The NAC RM23-20X is a 28-slot, 23 inch rack mountable housing that is designed to house up to type HDSL/T1 modules. The unit can be used to house up to 14 (type- 400) modules by only populating the odd numbered slots (i.e. 1, 3, 5 etc.). This assembly is designed to be mounted in a 23 inch rack assembly. This unit is ideal for applications between the facility multiplexer and the customer point of demarcation. The RM23-20X can be powered either with a plug-in power supply or external power via the supplied terminal block. 1.2 Whenever this product or document is changed, it will be reflected in this paragraph. 1.3 The RM23-20X provides the following features and capabilities: Mounting designed to house up to Type or 14 type-400 T1or HDSL modules Network connections made with 32-pair standard connectors Optional models for CPE connections to be made with 32-pair connectors, RJ48C jacks or Wire-Wrap headers. Locally powered with a plug-in power supply or external power supply. Rear protected cover provided. Locking front door option. Steel constructed assembly to meet NEBS requirements. 2. APPLICATIONS Figure 1. RM23-20X 2.1 The RM23-20X will house up to 28 type- 200 or 14 type-400 T1or HDSL modules. 2.2 The RM23-20X is designed to be mounted in a 23 rack and is ideal for applications where a facility multiplexer is present at the customer premise to terminate the customer services. This assembly can be locally powered from a type- 400 plug-in power supply module or from external power applied to the RM23-20X terminal block. Please refer to table 2 for wiring connections. 3. INSTALLATION 3.1 This mounting is designed to be installed by trained, authorized personnel only and must be installed in accordance with the local standards and practices for T1 (High Capacity Mb/s) services, or HDSL Services. This assembly is designed to be installed using common hand tools. 3.2 The assembly is designed to be used in a 23 relay rack. The mounting ears are factory set in the forward most position. The mounting ears can be adjusted 1 or 2 inches farther towards the back. 3.3 Facility side connections Facility connections are made to two 32-pair amphenol type connectors, See table 1 for facility/cpe wiring connections and figure Type or 200 Mechanics a registered trademark of Westell, Inc. Page 1 of 5

2 3.4 CPE side connections On the RM23-200, Customer (CPE) connections are made to the two (2) 32-pair amphnol-type connectors. See table 1 for facility/cpe wiring connections and figure Power connections The RM23-20X can be powered either with a plug-in 400-type power supply or external power via the supplied terminal block. The external power connections are made to the Power Terminal Block. A redundant power source can be connected to the B terminals. See Figure 5. Figure 2. RM rear view On the RM23-201, Customer (CPE) connections are made to RJ48C jacks. See table 1 for facility/cpe wiring connections and figure 3. Figure 5. RM23-20X Terminal block connections 3.6 Grounding Grounding connections are be made on either side of the mounting on studs provided. These studs are spaced 5/8 apart. See figure 6. Figure 3. RM rear view On the RM23-203, Customer (CPE) connections are made to Wire-Wrap pins. Each circuit is labeled. See figure 4. Figure 6. RM23-20X Ground Studs CAUTION: The ground studs must be directly (and separately) connected to an earth ground. This must be done to properly ground the assembly as well as all Network Interface Device front panels. Figure 4. RM rear view 3.7 If the Locking front cover is supplied, slide hinge pins on door into slots on the front bottom of the mounting. With the lock in the unlocked position, close door. The lock can now be turned back into the locked position. See figure 7. Page 2 of 5

3 Figure 8. RM23-20X Front View Figure 7. RM23-20X-1 Locking Front Door 3.8 Please observe the following safety precautions before installing the RM23-20X. a) Never install telephone wiring during a lightning storm. b) Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. c) Use caution when installing or modifying telephone lines. d) Never touch uninsulated telephone wires or terminals unless disconnected at the network interface. 4. TESTING 4.1 Prior to testing the units installed in the assembly, verify that all of the wiring connections have been made. 4.2 An ESD strap must be used when installing or testing modules. a)ensure mounting is properly grounded. b)attach the ESD wrist strap to bare skin and tighten the strap. c)grasp the spring alligator clip on the ESD wrist strap and clip to bare metal on the mounting to dissipate any static charge. 4.3 Once all of the proper powering, grounding, facility and CPE connections have been made, the modules can be installed tested according to their individual manufacturers specifications. Refer to the manufacturers practice for testing instructions. See figure CUSTOMER SERVICE If technical or customer assistance is required, please contact NAC at the following address or phone number: N A Communications, LLC 3820 Ohio Ave. Suite 12 St. Charles, Illinois Toll Free: Voice: (630) WARRANTY & REPAIRS 6.1 Warranty NAC warrants this product for the period specified by the terms governing the sale of the product. Any attempt to repair or modify the equipment by anyone other than an authorized NAC representative will void the warranty. This limited warranty does not cover any losses or damages resulting from shipment to or from the customer, or from improper installation, abuse, modifications, or unauthorized repair by other than NAC personnel. 6.2 Repair and Return NAC equipment will be repaired or replaced without cost during the warranty period if the product is defective for any reason other than abuse, improper use, or improper installation. Before returning defective equipment, first request a Return Material Authorization (RMA) number from NAC. Once an RMA number is obtained, return the unit, freight prepaid, along with a brief description of the problem, to: N A Communications, LLC 3820 Ohio Ave. Suite 12 St. Charles, Illinois ATTN: Repair & Return Dept. Page 3 of 5

4 7. SPECIFICATIONS 7.1 Physical Specifications Feature U.S. Metric Height 6.85 inches 17.4 cm Width inches cm Depth inches cm RM pounds 3990 g RM pounds 4535 g RM pounds 4310 g RM23-AC pounds 725 g 7.2 Environmental Specifications Feature U.S. Metric Operating Temperature -40 to 185 F -40 to 85 C Humidity 0 to 95% (non-condensing) 8. ORDERING Product Description connectors and CPE 32-pair connectors connectors and CPE RJ48C Jacks connectors and CPE Wire-Wrap headers connectors and CPE 32-pair connectors with locking front cover connectors and CPE RJ48C Jacks with locking front cover connectors and CPE RJ48C Jacks with locking front cover Locking front cover for RM23-20X Order Number RM RM RM RM RM RM RM23-AC01 Page 4 of 5

5 RM23-20X Table 1 Facilty and CPE Wiring Connections Page 5 of 5

Westell DBMA Position DS3 Mounting Assembly

Westell DBMA Position DS3 Mounting Assembly ection DBM-A20-024-201 Equipment Issue 1 030-101669 Rev. B, August 2010 Westell DBMA200-24 24-Position D3 Mounting Assembly CLEI* Code: NCM2YY0DRA CONTENT PAGE # 1. GENERAL....................................

More information

VirtualEdge VEUP-30 Universal Panel, with 3 LGX-Type Positions and 12 Keystone Coupler Positions

VirtualEdge VEUP-30 Universal Panel, with 3 LGX-Type Positions and 12 Keystone Coupler Positions Section VEU-P30-20A Equipment Issue A 030-101690 Rev. B, December 2008 VirtualEdge VEUP-30 Universal Panel, with 3 LGX-Type Positions and 12 Keystone Coupler Positions PART # PAGE # 1. GENERAL....................................

More information

VirtualEdge VELGX 90 Media Panel, with Nine LGX Type Positions, Front Tray, and Top Cover

VirtualEdge VELGX 90 Media Panel, with Nine LGX Type Positions, Front Tray, and Top Cover Section VEL GX9 20A Equipment Issue A 030 300323 Rev. A, June 2014 VirtualEdge VELGX 90 Media Panel, with Nine LGX Type Positions, Front Tray, and Top Cover PART # PAGE # 1. GENERAL... 1 2. INSTALLATION...

More information

VirtualEdge VEUP-BNC6P DS3 Protection Panel

VirtualEdge VEUP-BNC6P DS3 Protection Panel Section VEU-PBN-C6P-20A Equipment Issue A 030-101700 Rev. B, April 2010 VirtualEdge VEUP-BNC6P DS3 Protection Panel PART # PAGE # 1. GENERAL.................................... 1 2. INSTALLATION...............................

More information

428 Jack Panel Module

428 Jack Panel Module Charles Industries, Ltd. Section 042 800 201 Equipment Issue 1 Second Printing, May 1999 428 Jack Panel Module CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Westell. Breaker Panel Technical Practice NPDRP1114

Westell. Breaker Panel Technical Practice NPDRP1114 030-000218 REV F 1114-03F June 29, 2017 Westell Breaker Panel Technical Practice NPDRP1114 FEATURES DIN rail panel accepts up to 6 DIN rail devices (one surge and 5 breakers) Specific configuration of

More information

Breaker Panel Technical Practice NPDRP1114

Breaker Panel Technical Practice NPDRP1114 030-000218 REV E 1114-03E January 30, 2013 Westell Breaker Panel Technical Practice NPDRP1114 FEATURES DIN rail panel accepts up to 6 DIN rail devices (one surge and 5 breakers) Specific configuration

More information

SERVICE MANUAL MODEL SSW-520-F

SERVICE MANUAL MODEL SSW-520-F SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West

More information

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...

More information

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis 5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital

More information

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X) SSP-550-X-(SSP-510-X)-LPSPKRPCB-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-550-X (FORMERLY SSP-510-X) HANDS FREE ELEVATOR PHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry Since

More information

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE MHW-341-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE EQUIPPED WITH VOLUME CONTROL, BACKGROUND NOISE ELIMINATION, XFD PRINTED CIRCUIT, AND RECEIVER- OPERATED

More information

SERVICE MANUAL MODEL SSW-321-X

SERVICE MANUAL MODEL SSW-321-X SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,

More information

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD SSC-500-F-(501-FSZ)-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry

More information

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F SSW-321-F OR BLW-321-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-F OR MODEL BLW-321-F MINI WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering

More information

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS)

SERVICE MANUAL MODEL SSC-303-D (FORMERLY 303-DS) SSC-303-D(303DS)-ADI2.01-650-541-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-303-D (FORMERLY 303-DS) STAINLESS STEEL AUTOMATIC DIALING TELEPHONE EQUIPPED WITH ADI2.01 FIMWARE Serving the Telephone Industry Since

More information

SERVICE MANUAL MODEL SSP-350-X

SERVICE MANUAL MODEL SSP-350-X SSP-350-X-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-350-X PRISON VISITATION TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,

More information

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F) SSC-301-F OR BLC-301-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-301-F (FORMERLY 301-FS) OR MODEL BLC-301-F (FORMERLY 301-F) CHARGE-A-CALL TELEPHONE Serving the Telephone Industry Since 1930 Communication

More information

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V PagePac Issue 3 by PAGEPAC PLUS ZONE EXPANSION UNIT V-5335100 INTRODUCTION The Zone Expansion Unit (ZEU) provides up to 16 zones of audio output (including talkback), contact closure outputs or inputs.

More information

SERVICE MANUAL MODEL SSW-521-D2-ADA

SERVICE MANUAL MODEL SSW-521-D2-ADA SSW-521-D2-ADA-SPK1.07UNVLr3-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-D2-ADA STAINLESS STEEL HANDS FREE WALL TELEPHONE WITH OPTIONAL ADA FEATURE AND OPTIONAL SECOND-NUMBER AUTO-DIAL FEATURE EQUIPPED

More information

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA WPP-531-X-ADA OR SSP-511-X-ADA-SPK1.07-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA HANDS FREE EMERGENCY WEATHERPROOF TELEPHONE OR MODEL SSP-511- X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED

More information

SERVICE MANUAL MODEL SSW-321-D

SERVICE MANUAL MODEL SSW-321-D SSW-321-D-XFD-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-321-D MINI WALL TELEPHONE EQUIPPED WITH XFD PRINTED CIRCUIT BOARD Communication Equipment & Engineering Company Serving the Telephone Industry Since

More information

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS) SSW-521-F-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-F (FORMERLY SSW-521-FS) STAINLESS STEEL HANDS FREE WALL TELEPHONE OPTIONAL ADA FEATURE AVAILABLE EQUIPPED WITH SPK1.07UNVL FIRMWARE Serving

More information

Power Supply (48Vdc, 2.5A)

Power Supply (48Vdc, 2.5A) Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.

More information

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE WPP-531-D OR SSP-511-D-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE WITH OPTIONAL ADA

More information

Six-Slot T1 Mini-Repeater Apparatus Case

Six-Slot T1 Mini-Repeater Apparatus Case Telecommunications Group Section 282 600 201 Equipment Issue 1 Fourth Printing, August 2006 2826 00 Six-Slot T1 Mini-Repeater Apparatus Case CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

SERVICE MANUAL. MODEL SSW-321-Fr1

SERVICE MANUAL. MODEL SSW-321-Fr1 SSW-321-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL SSW-321-Fr1 MINI WALL TELEPHONE EQUIPPED WITH RECEIVER-OPERATED MAGNETIC HOOKSWITCH; INTERNAL VOLUME CONTROL AND NOISE REDUCTION CIRCUIT; XFD PCB. Serving

More information

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E) SSP-363-E-(SSP-365-E)-ADT1.03-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-363-E (FORMERLY SSP-365-E) STAINLESS STEEL PANEL TELEPHONE WITH 12 BUTTON AUTOMATIC DIALER EQUIPPED WITH ADT1.03 FIRMWARE Serving the

More information

to 48V DC Power Supply

to 48V DC Power Supply Telecommunications Group Section 855-080-201 Equipment Issue 1 Second Printing, July 2007 8550-80 24 to 48V DC Power Supply Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Type 400 Mounting Shelves

Type 400 Mounting Shelves Charles Industries, Ltd. Third Printing, March 1999 Type 400 Mounting Shelves CONTENTS PAGE Part 1. GENERAL............................................................................. 2 Part 2. INSPECTION...........................................................................

More information

MA-4006, MD-4006 and MU-4006 Mounting Assemblies

MA-4006, MD-4006 and MU-4006 Mounting Assemblies Telecommunications Group Section MA4 006 002 Equipment Issue 2 Second Printing, June 2000 MA-4006, MD-4006 and MU-4006 Mounting Assemblies CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1. WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches SSP-3-F -ISSUE 4.0 Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 0, or 5 -BK Braille Keypad -PBVC Pushbutton

More information

SERVICE MANUAL MODEL SSP-561-X-ADA

SERVICE MANUAL MODEL SSP-561-X-ADA SSP-561-X-ADA- SPK1.07r2-ISSUE4.0 SERVICE MANUAL FOR MODEL SSP-561-X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED WITH BRAILLE EMERGENCY PLATE AND SPK1.07r2 FIRMWARE Serving the Telephone Industry

More information

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE WPP(HOB)-331-D or SSP-311-D ATD-11 Issue 5.00 SERVICE MANUAL FOR MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE EQUIPPED

More information

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE WPP(HOB)-531-D OR SSP-511-D-SPK1.07UNVLADA-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 10, or 15 -BK Braille Keypad -PBVC Pushbutton volume control

More information

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE WPP(HOB)-531-D2 OR SSP-511-D2-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE OR MODEL SSP-511-D2 STAINLESS STEEL PANEL

More information

6-Circuit ( ) and 3-Circuit ( ) 56/64xN Data Service Unit (DSU) Data Port (DP)

6-Circuit ( ) and 3-Circuit ( ) 56/64xN Data Service Unit (DSU) Data Port (DP) Telecommunications Group Section 363-480-201 Equipment Issue 1 Seventh Printing, September 2006 6-Circuit (3634-80) and 3-Circuit (3634-81) 56/64xN Data Service Unit (DSU) Data Port (DP) CONTENTS PAGE

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

SERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)

SERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS) SSC-303-F-650-521-CAC6.00-ISSUE4.1 SERVICE MANUAL FOR MODEL SSC-303-F (FORMERLY 303-FS) CHARGE-A-CALL TELEPHONE EQUIPPED WITH CAC6.00 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment

More information

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007 Sun StorageTek nl 1U Rackmount Media Tray Reference Guide Sun Doc Part Number: 875 4297 10 Second edition: December 2007 Legal and notice information Copyright 2007 Hewlett Packard Development Company,

More information

Ethernet Test Access Panel (ETAP) User Manual

Ethernet Test Access Panel (ETAP) User Manual Ethernet Test Access Panel (ETAP) User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................

More information

Enginuity DST5417 Issue 3 2W/4W Data Station Termination with 309B-Type Equalization, Loopback and Jacks

Enginuity DST5417 Issue 3 2W/4W Data Station Termination with 309B-Type Equalization, Loopback and Jacks Enginuity DST5417 Issue 3 2W/4W Data Station Termination with 309B-Type Equalization, Loopback and Jacks CLEI* Code: DSTNV4Y3AA CONTENTS PAGE# 1. GENERAL 1 2. APPLICATIONS 2 3. CIRCUIT/FUNCTIONAL DESCRIPTION

More information

Dell OptiPlex All-in-One. Stand Installation Guide

Dell OptiPlex All-in-One. Stand Installation Guide Dell OptiPlex All-in-One Stand Installation Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7 SECTION 4 - FRONT PANEL INDICATORS...8 SECTION 5 - INTERFACE SIGNALS...9 SECTION 6 -

More information

Rackmount Keyboard Installation Instructions. Revision A A-0000

Rackmount Keyboard Installation Instructions. Revision A A-0000 Rackmount Keyboard Installation Instructions Revision A 22000200A-0000 WARRANTY The following is an abbreviated version of warranty policy for keyboard products. For a complete warranty statement, contact

More information

Installing The Loop Start Line Board In The FX Series Digital Communications System

Installing The Loop Start Line Board In The FX Series Digital Communications System R In The FX Series Digital Communications System Introducing The Loop Start Line Board Defining Loop Start The line board signals for the host system to complete a line connection by sending a supervisory

More information

Universal Switch Panel USP-KEYSERVER. User Manual

Universal Switch Panel USP-KEYSERVER. User Manual 12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrols.com Universal Switch Panel USP-KEYSERVER User Manual Rev 1.0 USP-KEYSERVER User Manual 1 OF 10 TABLE OF

More information

Analog Door Phone Model LUADS

Analog Door Phone Model LUADS Analog Door Phone Model LUADS Installation and Use Manual Telephone line powered Two-way, hands-free communication Vandal-resistant brushed stainless steel faceplate with mounting gasket and heavy-duty

More information

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2 OPERATING PROCEDURES for the Universal Power Supply Series 2 Vanguard Instruments Co., Inc. 1520 S. Hellman Ave. Ontario, California 91761 TEL: 909-923-9390 November 2013 FAX: 909-923-9391 REV. 2 SAFETY

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300 Model CMX-300 Technical Practice October 2015 Issue 6 MODEL CMX-300 Service Observing System 1. GENERAL 1.1 The Dees CMX-300, installed with the Dees CM-30, increases the number of stations to be observed

More information

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack The NT1-220 Rack is designed to be used in conjunction with Tone Commander NT1U-220TC ISDN Network Terminations. A maximum of twelve NT1 units can be used in each rack. NT1-220 Rack Installation Instructions

More information

MODEL No. SW1X8 RS422 SWITCHER

MODEL No. SW1X8 RS422 SWITCHER 12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com MODEL No. SW1X8 RS422 SWITCHER User Manual TABLE OF CONTENTS I. REVISION HISTORY... 2 II. INTRODUCTION...

More information

LED-200P. Mobile LED Light Set. User Manual

LED-200P. Mobile LED Light Set. User Manual LED-200P Mobile LED Light Set User Manual 2 Welcome Thank you for choosing Xuma. The LED-200P is a compact, durable, and versatile LED light set that is as useful at home as it is on the go. A variety

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Intelligent Channel Bank Shelf

Intelligent Channel Bank Shelf Telecommunications Group Section 360-080-204 Equipment Issue 4 Third Printing, August 2006 360-80 Intelligent Channel Bank Shelf CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

STRATUS ULTRA-G User Guide

STRATUS ULTRA-G User Guide STRATUS ULTRA-G User Guide Table of Contents Introduction..................................................................1 Stratus Ultra-G Components......................................................1

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

AI180I AIswitch Series 180 Integrated Chassis Installation Guide AI180I AIswitch Series 180 Integrated Chassis Installation Guide Part Number QR-180I Rev 5 2008 by Kentrox, Inc. All rights reserved. Copyright 2008 by Kentrox, Inc. All Rights Reserved. The material discussed

More information

Westell DTWA Series of 28-Position Digital Terminating Wall Assemblies

Westell DTWA Series of 28-Position Digital Terminating Wall Assemblies Section DW-A--0 Equipment Issue 030-066 ev. A, February 00 Westell DWA- Series of -Position Digital erminating Wall Assemblies CONENS PAGE #. GENEAL..................................... INSALLAION...............................

More information

UTAH-100/XHDA SERIES

UTAH-100/XHDA SERIES Utah Sandar AS User Manual & Installation Guide UTAH-100/XHDA SERIES SD & HD3G Digital Distribution 1:4 & 1:8 CONTENTS CONTENTS... 2 INTRODUCTION... 3 WARRANTY... 3 DOCUMENT REVISION HISTORY... 3 SAFETY

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication

More information

PARTNER Contact Closure Adjunct

PARTNER Contact Closure Adjunct Closure Installation Instructions BEFORE STARTING INSTALLATION, READ AND UNDERSTAND ALL SAFETY INSTRUCTIONS ON PAGE. The is used with a Advanced Communications System processor module (available separately)

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

PCM PC/ bit Digital I/O Module. User Manual

PCM PC/ bit Digital I/O Module. User Manual PCM-3724 PC/104 48-bit Digital I/O Module User Manual Copyright This documentation and the software included with this product are copyrighted 2008 by Advantech Co., Ltd. All rights are reserved. Advantech

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM 10-Port Industrial USB 3.0 Hub - ESD and Surge Protection StarTech ID: ST1030USBM This 10-port USB 3.0 hub gives you the scalability you need in harsh industrial environments. It s designed to meet the

More information

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL STATIC METERS Models 211 & 212 SURVEYORSTAT Models 211XL & 212XL Operating Manual 5/09 1.0 GENERAL DESCRIPTION The Model 211 and 212 Static Meters, shown in Figures 1.0-1a and b, are accurate, compact

More information

F280XD Fiber-Optic RS-232 Modem Technical Manual

F280XD Fiber-Optic RS-232 Modem Technical Manual F280XD Fiber-Optic RS-232 Modem Technical Manual Revision B August 2012 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY DATA

More information

829MA 6 and 829MB 6 Data Mountings

829MA 6 and 829MB 6 Data Mountings Telecommunications Group Section 829 MA6 001 Equipment Issue 1 Third Printing, June 2001 829MA 6 and 829MB 6 Data Mountings CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad ipad Charge & Sync Cart Model MCC2 ipad Cart ipad Is a Registered Trademark of Apple Inc. 430-MCC2-User Manual-010 1. ipad Cart Specifications MCC2 Mobile Charge & Sync Cart Extra Drawer Reserved space

More information

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

Model SPDT Mercury Wetted Relays

Model SPDT Mercury Wetted Relays Model 4511 32 SPDT Mercury Wetted Relays 90900010 Page 1 All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part

More information

CUBE Micro Station User Guide

CUBE Micro Station User Guide CUBE Micro Station User Guide Models TVS10AC CUBE Micro Station - User Guide 1 of 23 How To Use This Guide This User Guide is a resource to provide you guidelines and best practices as you begin using

More information

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual

SmartBoom PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U. Operating Manual SmartBoom Operating Manual PRO PHS-SB100-4F, PHS-SB100-5M, PHS-SB100-U, PHS-SB200-4F, PHS-SB200-5M, PHS-SB200-U Thank You We at Pliant Technologies, LLC want to thank you for purchasing the SmartBoom PRO

More information

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental

More information

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction Page 1 of 16 MODULUS 21 Power Distribution Unit (PDU) Replacement Overview Introduction This notice explains how to replace the AC Power Distribution Unit (PDU), also known as a Power Distribution Assembly

More information

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R LOOP TELECOMMUNICATION INTERNATIONAL, INC. 8F, NO. 8, HSIN ANN

More information

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection User Manual MIOe-3680 2-port CAN-bus PCIE/MIOe Module with Isolation Protection Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co., Ltd. All rights

More information

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume INSTRUCTION MANUAL English...1 Français...9 Español...17 Deutsch...25 Italiano...33 Português do Brasil...41 200B-G Tone Probe with Adjustable Volume 200EP-G Tone Probe with Adjustable Volume, Visual Signal

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

OPERATIONS MANUAL PCM-I/O48

OPERATIONS MANUAL PCM-I/O48 OPERATIONS MANUAL PCM-I/O48 NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual

More information

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web TM 9109 FXS Analog Voice Application Module (APM) Installation Instructions Document Number 9109-A2-GN12-40 May 1999 Product Documentation on the World Wide Web We provide complete product documentation

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ohm Metrics Wrist Strap & Footwear Combination Tester GTS600 Instruction

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting MIC-3001/8 3U/4U CompactPCI Enclosure for Rackmounting Copyright Notice This document is copyrighted, 1999. All rights are reserved. The original manufacturer reserves the right to make improvements to

More information

Customer Upgrade Procedure

Customer Upgrade Procedure Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive

More information

AMP Rack User Manual. Publication Rev G

AMP Rack User Manual. Publication Rev G Publication Introduction This manual contains information for the AMP Rack from Forney Corporation, 16479 Dallas Parkway, Suite 600, Addison, Texas. www.forneycorp.com All personnel should become thoroughly

More information