PI-EX-ME-2NAM/COC-24VDC
|
|
- Camilla Cannon
- 5 years ago
- Views:
Transcription
1 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC is a two-channel 3-way isolation amplifier. It is designed to operate proximity switches according to DIN EN as well as switch contacts with open circuit and resistance circuit. The signals from the Ex area are transmitted to the control system located within the safe area via a relay output. The module itself is installed in the safe area and only the sensor cable is led into the hazardous area (zone 0, zone, zone, zone 0, zone or zone ). The PI-EX-ME-NAM/COC-4VDC features line fault detection (LFD) for each channel, which can be switched on/off depending on the application. If a line fault is detected or a supply voltage failure occurs, the module switches to the OFF state, i.e., the main contact is open. A switch is used to switch each channel between normal and inverse mode.. Properties Two-channel Input for NAMUR proximity sensor or switch, [EEx ia] IIC Relay output 0 V DC V DC supply 3-way electrical isolation Option of phase reversal Line fault detection (LFD) The device is an associated item of equipment and must not be installed in potentially explosive areas. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. Observe the safety regulations and installation notes on page 5. Make sure you always use the latest documentation. It can be downloaded at A conversion table is available on the Internet at This data sheet is valid for all products listed on the following page:
2 Table of Contents Description... Ordering Data... 3 Technical Data... 4 Safety Regulations and Installation Notes Structure Basic Circuit Diagram Configuration Installation Comparison of Safety Data... 8 Ordering Data NAMUR Isolation Amplifier Description Type Order No. Pcs./Pck. Ex-i NAMUR isolation amplifier, with intrinsically safe input, relay output, PDT, two-channel, 4 V DC supply PI-EX-ME-NAM/COC-4VDC Accessories Description Type Order No. Pcs./Pck. Loop wire jumper, 50-pos., can be separated, maximum jumpering distance of 60 mm, for jumpering identical inputs and outputs, 0.5 mm², insulation: Black Blue Gray DB BK DB BU DB GY For additional accessories, please refer to the "INTERFACE" catalog from Phoenix Contact. 3 Technical Data Input Control circuit Intrinsically safe Available input sources NAMUR proximity switches according to EN Switch contacts with open circuit Switch contacts with resistance circuit (series resistance kω ±0%, parallel resistance 0 kω ±0%) Control Circuit Non-load voltage Switching points Blocking Conductive Line fault detection 8.5 V DC <.55 ma >.75 ma Can be disabled by jumpering X - X or X5 - X6 0033_0_en PHOENIX CONTACT
3 Output Switching output Configurable/programmable Contact type Limiting continuous current Minimum contact current Maximum switching power Mechanical service life Relay output Switching behavior can be inverted via switch on the front of the housing (see "Configuration" on page 7) PDT per channel 5 A (50 V AC) A (00 V DC) ma 00 VA (50 V AC) 50 W (00 V DC) 0 7 cycles Transmission Behavior Switching behavior Switching frequency Can be inverted via switch 0 Hz, maximum Connection Data Conductor cross-section Solid (minimum/maximum) Stranded (minimum/maximum) AWG/kcmil (minimum/maximum) Stripping length Thread Connection method Tightening torque 0. mm /.5 mm 0. mm /.5 mm 4/4 8 mm M3 Plug-in screw connection 0.5 Nm, minimum/0.6 Nm, maximum General Data Supply voltage range 0 V DC V DC Current consumption < 50 ma (4 V DC) Power consumption 0.55 W (per channel) Number of channels Electrical isolation (input/output/supply) 375 V (peak value according to EN 5000) Test voltage (input/output).5 kv AC, 50 Hz, min. Housing material Polyamide PA, not reinforced Color Green Degree of protection IP0 Width x length x height.5 mm x 99 mm x 4.5 mm Inflammability class according to UL 94 V0 Design Terminal block housing for mounting on DIN rails Connection method Plug-in screw terminal blocks NAMUR recommendation NE Climatic Data Ambient temperature (operation) Ambient temperature (storage/transport) Permissible humidity (operation) -0 C C -5 C C < 75% (annual average) < 95% (30 days/year, no condensation) Indicators Status indicator Green LED (supply voltage) Yellow LED (switching state) Red LED (line fault) 0033_0_en PHOENIX CONTACT 3
4 EC Conformance EMC directive 89/336/EEC Ex directive (ATEX) Yes Yes Safety Data According to ATEX for Intrinsically Safe Circuits Maximum output voltage U o Maximum output current I o Maximum output power P o Gas group Maximum external inductance L o Maximum external capacitance C o U m 0.5 V 6 ma 67 mw 50 V AC IIB 60 mh 6.8 μf IIC 45 mh.4 μf Approvals CE Yes ATEX X II () GD [EEx ia] IIC, TÜV 00 ATEX 58 UL/CUL U C.D. No. 00-T48 (see "UL/CUL Approval" on page 6) 0033_0_en PHOENIX CONTACT 4
5 4 Safety Regulations and Installation Notes 4. Installation and Operation Follow the installation instructions. NOTE: Installation, operation, and maintenance may only be carried out by qualified specialist personnel. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. NOTE: The circuits inside the device must not be accessed. Do not repair the device yourself, replace it with an equivalent device. Repairs may only be carried out by the manufacturer. NOTE: The device must not be subject to mechanical strain and/or thermal loads, which exceed the limits described in these operating instructions. NOTE: The device is only designed to meet IP0 protection in a clean and dry environment. In order to provide protection against mechanical or electrical damage, install the device in corresponding housing with a suitable degree of protection according to IEC Where dust is present, install the device in suitable housing with at least IP5x protection. 4. Safety Regulations for Installation in Potentially Explosive Areas The device is an associated item of equipment and must not be installed in potentially explosive areas. Regulations for Intrinsically Safe Circuits When carrying out measurements on the intrinsically safe side, observe the relevant regulations regarding the connection of intrinsically safe equipment. Only use devices approved for use in intrinsically safe circuits. If the device has been used in non-intrinsically safe circuits, it must not be used again in intrinsically safe circuits. The module must be clearly labeled as non-intrinsically safe. For the safety data, please refer to the operating instructions and certificates (EC-type examination, other approvals, if necessary). Installation in Areas With a Danger of Dust Explosions The device is not designed for use in areas with a danger of dust explosions. Connection to the intrinsically safe circuit in areas with a danger of dust explosions (zone 0,, and ) is only permitted if the equipment connected to this circuit is approved for this zone (e.g., category D, D or 3D). 0033_0_en PHOENIX CONTACT 5
6 4.3 UL/CUL Approval 0033_0_en PHOENIX CONTACT 6
7 5 Structure.5 6 Basic Circuit Diagram Ex area Safe area CH CH 3 4 POWER I II I II [EEx ia] IIC [EEx ib] IIC UV UV 9 0 CH CH PI-Ex-ME-NAM/COC-4VDC POWER PI-Ex-ME-NAM/COC-4VDC Art.-Nr.: Suitable for Class I, Div., Groups A, B, C and D installation; providing intrinsically safe circuits for use in Class I, Div., Groups A, B, C and D; Class II, Groups E, F and G; and Class III Hazardous Locations. Drawing-No. 00-T48 APPROBATIONEN / APPROVALS U M68 I i I<0.mA V I>6.0mA LISTED R R I<0.mA I>6.0mA V I i ROT RED II REV ROT RED II REV & & GRÜN GREEN GELB YELLOW GELB YELLOW YE -5 INTERNGEBRÜCKT -5 CONNECTED INTERNALLY CH CH + 4VDC POWER CH I II I II CH CH 3 CH POWER PI-Ex-ME-NAM/COC-4VDC I<0.mA IV R i I>6.0mA + 6 U V RD & II REV RD + I<0.mA I>6.0mA + IV R i & - 3 U V II REV GN internally jumpered with 5 YE 4 0 CH YE 6 CH 3 + 4VDC 5-7 Figure Structure Switch for reversing the direction of operation: Switch in position I when contact is closed in the input circuit, activates the output Red LED, for indicating line fault detection: Line fault detection can only be activated if a proximity switch according to DIN EN or NAMUR or a mechanical contact with corresponding resistance circuit (see "Basic Circuit Diagram" on page 7) is connected. 3 Yellow LED, for indicating the switching state: LED is controlled parallel to the output 4 Green LED, for indicating the power supply. 5 Plug-in terminal blocks (to release with a flat-bladed screwdriver, push out laterally). 6 Direction for removing the screw terminal blocks 7 Metal lock for fixing on the DIN rail Figure Basic circuit diagram with connection terminal blocks 7 Configuration 7. Switching Function Table Input No error in the input circuit With error in the input circuit Sensor blocking, contact open Sensor conductive, contact closed Sensor blocking, contact open Sensor conductive, contact closed Line fault, short circuit or break Direction of operation Line fault detection Output Yellow LED (switching state) Red LED (line fault detection) Normal Any OFF OFF OFF Normal Any ON ON OFF Inverse Any ON ON OFF Inverse Any OFF OFF OFF Any ON OFF OFF ON Cable break Normal OFF OFF OFF OFF Cable break Inverse OFF ON ON OFF Short circuit Normal OFF ON ON OFF Short circuit Inverse OFF ON OFF OFF 0033_0_en PHOENIX CONTACT 7
8 7. Line Fault Detection Figure 3 NOTE: For mechanical contacts, line fault detection must be disabled (Figure 3) or the corresponding resistance circuit (Figure 4) must be provided directly at the contact (e.g., UKK 5-R/NAMUR (Order No. 9466) with D-UKK 3/5 (Order No )). Line fault detection disabled 8 Installation The device should only be transported and stored in its original packaging. 8. Mounting () () (3) Figure 4 0 kω.7 kω Switch contact with resistance circuit NOTE: Electrostatic discharge The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN and EN If the device has been used in non-intrinsically safe circuits, it must not be used again in intrinsically safe circuits. The module must be clearly labeled as non-intrinsically safe. Mount the device on a 35 mm DIN rail according to EN The device is calibrated by default upon delivery. For this reason, subsequent calibration of the zero point and final value is not provided. Before startup, check that the NAMUR isolation amplifier is operating and wired correctly, especially with regard to the wiring and labeling of the intrinsically safe circuits. () (3) 8. Connecting the Cables Plug-in screw terminal blocks; fit the litz wires with ferrules. Install intrinsically safe and non-intrinsically safe cables separately. Permissible cable cross-section: 0. mm to.5 mm. 8.3 Pre-Startup Checklist Before starting the device, make sure that the following conditions have been observed using the technical data: Checkpoint OK Operating conditions have been observed? Correct polarity has been selected for all connections? No impermissibly high voltage in the output circuits during startup? Output load corresponds to the permissible values according to "Output" on page 3? Output circuit grounded at no more than one location? All power supply values correct? 9 Comparison of Safety Data Safety data of: Compare the safety data before connecting a device located in the Ex-i area to the PI-EX-ME-NAM/COC-4VDC. Field devices: Isolation amplifier: U i, I i, P i, L i, C i U o, I o, P o, L o, C o For the values for U o, I o, P o, L o, and C o, please refer to "Safety Data According to ATEX for Intrinsically Safe Circuits" on page 4. Ex-i Requirements: U i U o I i I o P i P o L i + L c L o C i + C c C o (L c and C c depend on the cables/lines used) 0033_0_en PHOENIX CONTACT GmbH & Co. KG 383 Blomberg Germany Phone: PHOENIX CONTACT P.O.Box 400 Harrisburg PA USA Phone:
PI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationMACX MCR-EX-SL-NAM-R(-SP)
Intrinsically safe NAMUR isolating amplifier with relay output INTERFACE Data sheet 03463_en_00 PHOENIX CONTACT - 08/2008 Description The NAMUR MACX MCR-EX-SL-NAM-R(-SP) isolating amplifier has been designed
More informationMACX MCR-EX-SL-NAM-2RO(-SP)
Intrinsically safe NAMUR isolating amplifier with two relay outputs INTERFACE Data sheet 03465_en_00 PHOENIX CONTACT - 08/008 Description The NAMUR MACX MCR-EX-SL-NAM-RO(-SP) isolating amplifier has been
More informationMACX MCR-EX-SD LP(-SP)
Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)
More informationPHOENIX CONTACT - 02/2008
Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationRAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description
I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless
More informationLoop-powered Transmitter for Thermocouple Type K (NiCr-Ni)
Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationRAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description
I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationMACX MCR-EX-SL-2NAM-T(-SP)
NAMUR signal conditioner, Ex-i, 2-channel, with transistor output Data sheet 103753_en_00 PHOENIX CONTACT 2014-08-19 1 Description The 2-channel NAMUR signal conditioner MACX MCR-EX-SL-2NAM-T(-SP) has
More informationMINI MCR-SL-CVS NC
Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationMINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:
Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration
More informationTRIO-DIODE/12-24DC/2X10/1X20
Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy
More informationMINI MCR-SL-MUX-V8-FLK 16
Multiplexer Data sheet 445_en_4 PHOENIX CONTACT 22-5-2 Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6,
More informationMINI MCR-SL-PT100-UI(-SP)(-NC)
Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationRAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.
I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs INTERFACE Data sheet 104832_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DAIO6-IFS I/O extension module can be
More informationMACX MCR-EX-SL-RTD-I...
Temperature transducer with intrinsically safe input for resistance thermometers and resistance-type sensors INTERFACE Data Sheet 103945_en_00 PHOENIX CONTACT 2009-12-04 1 Description The programmable
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationMACX MCR-SL-(2)I-2)I-ILP(-SP)
Passive isolator, one and two channel Data sheet 106893_en_01 PHOENIX CONTACT 2015-12-07 1 Description The single- or dual-channel input loop powered 2-way isolator with plug-in connection technology is
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationQUINT-PS-3x AC/24DC/10
3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationEMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks
Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008
More informationEMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.
Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationMINI MCR-SL-UI-REL(-SP)
Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.
More informationMINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationMACX MCR-EX-SL-RPSS-2I-2I
2channel repeater power supply, Ex i Data sheet 105571_en_00 PHOENIX CONTACT 20140513 1 Description The 2channel repeater power supply is designed for the operation of intrinsically safe (Exi) 2wire measuring
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationQUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents
More informationPSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B
PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationMINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description
3-way signal conditioner Data sheet 106012_en_02 PHOENIX CONTACT 2016-02-19 1 Description The standard signal 3-way signal conditioner with pluggable connection technology is used to electrically isolate,
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationQUINT-BUFFER/24DC/24DC/40
Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationTRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationPSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description
SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More informationAssembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail
Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More informationD6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D
D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General
More informationMANUAL Surge Protectors
PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationPLC-RSC- 24DC/21 Order No.:
Typical release time Operating voltage display Name of protection Protective circuit/component 8 ms Yes Polarity protection Polarity protection diode Contact side Contact type Contact material Maximum
More informationExtract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards
Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs
More information1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX
1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas -PS-100-240AC/24/5/EX POWER provides: Preventive function monitoring through professional signaling Global use due to a
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More informationPSR-PS21. SIL coupling relay. Data sheet. 1 Description
SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationPLC-RSC- 24UC/21. Extract from the online catalog. Order No.:
Extract from the online catalog PLC-RSC- 24UC/21 Order No.: 2966184 The illustration shows the version PLC-RSC-24DC/21 PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and
More informationTermination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous
More informationVAL-CP-1S-175. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with
More informationWG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.
Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply
More informationOperating instructions
Operating instructions Digital Input Output Module > Contents 1 Contents 1 Contents...2 2 General information...3 2.1 Manufacturer...3 2.2 Information regarding the operating instructions...3 2.3 Conformity
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationSafety instructions VEGATOR 121, 122
Safety instructions Intrinsic safety IECEx TUN 14.0005X Document ID: 47471 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Installation... 4 Supplementary documentation:
More informationASI QUINT /2.4 EFD
Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678
More informationPHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic
More informationPower Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5
Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of
More informationTermination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationVAL-CP-3S-350. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page
More informationIntrinsically Safe Barriers
Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper
More information4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12
0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring
More information