onlinecomponents.com

Size: px
Start display at page:

Download "onlinecomponents.com"

Transcription

1 Uninterruptible Power Supply Unitfor Universal Use. Short Description Uninterruptible Power Supply Units for Buffering Long-Term terruptions Saves space thanks to the compact, uniform design Integrated diode saves money through isolation of loads Maximum system availability through optimum battery management and reliable signaling Minimum installation time due to ready-to-use plug-in bridges and integrated timeout QUINT-DC-UPS uninterruptible power supply units with long-life lead-acid batteries provide long buffer times at high currents. Even in the event of a longer supply voltage failure, the units ensure that all connected devices continue to operate without interruption. The devices have a narrow and uniform design, which makes them ideal for use on the DIN rail where space is limited. In addition, short wiring paths ensure order and clarity in the control cabinet. The high level of availability and the particularly long service life of the battery modules are achieved through professional battery management. An automatic presence check (every minute), automatic quality test (once a week), temperature-determined charging, and electronic overcurrent protection ensure the battery modules are ready to operate at all times. Power is therefore available in the event of an error and the service life of the battery module is maximized. The actual state must be determined quickly so that the right decision can be made in an emergency. Optimum signaling is thus required for maximum system availability. Three floating PDT contacts and three LEDs are provided for function monitoring, which indicate all the operating states clearly. So that relay signaling is more reliable and more durable than before, an additional positive supply output has been provided. The contact, which is current-limited and resistant to continued short circuits, is located next to the relay connections and enables easy bridging. In the event of wiring errors, the shortcircuit protection prevents any welding of the relay contacts. This ensures that the user can rely on an signal. Even in the event of connection errors, currents remain below 00 ma, which prevents damage to the relay contacts. A system is switched off after a specific time that can be set on the device or by an external signal. No additional installation is required for shutdown. In addition, ready-to-use plug-in bridges minimize the installation time. The connected devices can be divided into buffered and unbuffered loads using the isolated input. This extends the buffer time, which depends on the output current. If only critical devices are protected using fuses, smaller battery modules can be used that save money and space in the control cabinet. In addition, the isolated input protects the connected devices against errors in the internal network. Headquarters: Phoenix Contact GmbH & Co. KG Flachsmarktstraße 8 8 Blomberg Germany Phone Fax Local Contact:

2 N 8 Uninterruptible Power Supply Unit for Universal Use. Technical Data mm (4.9 in.) J E * = J A A? J ) D A JA BB ) = H * = JJA H O F K J, + " 8 " 8 ) K JF K J ), + + D = H C A * = A 0 mm (.8 in.) 66 mm (.98 in.) Solid Stranded Torque [mm ] AWG [Nm][ lb in] Input Output Signal Description Uninterruptible power supply unit.4 Ah battery module 7. Ah battery module Ah battery module Technical Data Input Data Nominal input voltage Input voltage range Current consumption Switching threshold Buffer time Input fuse Maximum power dissipation Output Data Can be connected in parallel (battery module) Output Data in Normal Operation Nominal output voltage Output voltage Output current Current limit Overload fuse Output Data in Buffer Mode Nominal output voltage Output voltage Output current Current limit Overload fuse Level of efficiency Remote shutdown Charging Charge characteristic curve End-of-charge voltage Charge current presence check/time interval quality test/time interval Memory Medium Nominal voltage Nominal capacity Charge current (no load/charging/maximum) Can be configured (Ready/buffer mode) Maximum (Typical) DC UPS Module 7 mm (0.8 in.) Type QUINT-BAT/4DC/,4Ah QUINT-BAT/4DC/7,Ah QUINT-BAT/4DC/Ah 4 V DC. - 0 V DC 0. A/.0 A/.0 A U a < V; dynamic U in - V/0.s 0.; ; ; ; ; 0; ; 0; 0; continuous Internal, A W/0 W Yes, to increase the buffer time 4 V DC U in 0 A None Internal, A 4 V DC 7.9 V DC 0 A 7 A Electronic 9% Yes I/U characteristic curve Temperature compensated <. A 60 seconds 80 hours External 4 V DC.4 Ah, 7. Ah, Ah <. A U u F Order No Pcs. Pkt. PHOENIX CONTACT page of 9

3 Uninterruptible Power Supply Unit for Universal Use Signaling Mode Charge Approvals/Standards Electrical equipment of machines Electrical safety (of IT equipment) Industrial control equipment Shipbuilding Electronic equipment for use in electrical power installations Green LED Red LED, floating PDT, 0 V AC/DC, maximum; A, maximum Yellow LED, floating PDT, 0 V AC/DC, maximum; A, maximum Yellow LED, flashing, floating PDT, 0 V AC/DC, maximum; A, maximum EN EN 6090/VDE 080, UL/C-UL Recognized UL UL/C-UL Listed UL 08 Germanischer Lloyd EN 0 78/VDE 060 General Data Insulation voltage Mounting position Input/output to housing: Degree of protection Class of protection MTBF According to IEC 709 (SN 9 00) Housing version Dimensions (W x H x D) default upon delivery Dimensions (W x H x D) rotated 90 Weight Approximately Climatic Data Ambient temperature Operation/storage Humidity At + C (+77 F) Vibration According to IEC Shock (in all space directions) According to IEC Pollution degree According to EN 0 78 Climatic category According to EN 60 7 c Conformance With EMC Directive 89/6/EEC and Low Voltage Directive 7//EEC EMC (Electromagnetic Compatibility) Noise Immunity Acc. to EN EN ) Electrostatic discharge (ESD) EN ) Electromagnetic HF field EN ) Fast transients (burst): EN ) Surge current loads (surge): EN ) Conducted interference Housing Contact discharge: Air discharge: Housing Frequency/Field strength: Input, output: Signal: Input, output, signal: kv AC type test kv AC routine test On a horizontal mm (.78 in.) DIN rail EN 60 7 kv/ kv IP0 II > 00,000 h AluNox (AlMg), closed (66 x 0 x mm [.98 x.8 x 4.9 in.]) ( x 0 x 69 mm [4.80 x.8 x.77 in.]) 0.8 kg - C to +70 C (- F to +8 F)/-40 C to +8 C (-40 F to +8 F) 9%, no condensation Hz - 0 Hz,. g, 90 minutes 0 g K Level 4 8 kv kv Level MHz/0 V/m kv (Level ) 4) kv (Level ) 4) 0. kv 4) /0. kv )/(Level ) I/O/S: Frequency/U 0 : Level MHz/0 V Noise Emission According to EN 008- Radio interference emission Radio interference voltage EN 0 corresponds to CISPR/EN 0 corresponds to CISPR/EN 6000 corresponds to IEC 000 ) Criterion A: Normal operating characteristics within the specified limits. ) Criterion B: Temporary adverse effects on the operating characteristics that the device corrects automatically. ) Symmetrical: Cable to cable. 4) Asymmetrical: Cable to ground. ) Class B: Industrial and domestic applications. EN 0 (EN 0) Class B ) EN 0 (EN 0) Class B ) PHOENIX CONTACT page of 9

4 Uninterruptible Power Supply Unit for Universal Use. Device View, Connections, and Control Elements 7 8 DC DC 4 V 0 A Input Output DC input: 4 V unbuffered Input voltage 4 V DC (0. mm to 6 mm solid) (0. mm to 0 mm stranded) (0-6 AWG) Internal fuse AT DC output: 4 V buffered Output voltage 4 V DC (0. mm to 6 mm solid) (0. mm to 0 mm stranded) (0-6 AWG) The device is idling-proof and short-circuit-proof. 4 V battery module connection 4 Floating PDT (,,): Floating PDT (,,): Mode 6 Floating PDT (,,) 7 4 V supply voltage, maximum current limit 0. A for grouped contacts,, 8 Remote shutdown (R, R) 9 Universal DIN rail adapter UTA 07 0 Red LED: Yellow LED: Mode/ Charge " Green LED: Buffer time setting minutes $ module/ setting selection 6 +4V 0,A R R R R Remote OFF ON Bat.- Bat.- Mode Charge QUINT DC-UPS 0 A DC + + 0, 0 0 0,4 7, Order-No.: Input: 4VDC/A Operational Voltage:.-0VDC Output: 4VDC/0A C F APPROVALS U INDUSTRIAL LISTED Read installation instructions before connecting 4. Safety Notes and Warning Instructions To ensure that the device can be operated safely and all functions can be used, please read these instructions carefully. Caution: Never carry out work when the power is turned on, this is highly dangerous. CONTROL EQUIPMENT 4KA F $ EN EN " 0 Figure 04 The QUINT-DC-UPS is a built-in device. Installation and startup must only be carried out by qualified personnel. The relevant country-specific regulations (e.g., VDE, DIN) must also be observed. Before startup it is particularly important to ensure that: All supply lines have sufficient fuse protection and are the correct size. All output cables are the correct size for the maximum device output current or have separate fuse protection. Sufficient convection is ensured. PHOENIX CONTACT page 4 of 9

5 Uninterruptible Power Supply Unit for Universal Use. Installation.. Mounting The uninterruptible power supply unit together with the battery module can be snapped onto all DIN rails according to EN 607 and should be mounted horizontally (input terminal blocks facing downwards). DC + 4 Installation Dimensions No minimum spacing to other modules is required for proper operation of the device... Narrow Mounting Position The device is supplied ex works for a narrow mounting position. Mounting: Place the module with the DIN rail guideway on the top edge of the DIN rail and then snap it downwards. Removal: Release the snap-on catch using a screwdriver and then detach the module from the bottom edge of the DIN rail... Flat Mounting Position A flat mounting position can be achieved by mounting the module onto the DIN rail at a 90 angle. To do this, mount the DIN rail adapter (UTA 07) 7 as shown in Figure 7. No additional assembly material is required. Mounting screws: Torx T0 (torque Nm). Mounting Removal +4V 0,A DC 4 V 0 A Input Output QUINT DC-UPS 0 A DC + + R R Bat.- Bat.- Mode Charge R R Remote OFF ON 0, 0 0 0,4 7, Order-No.: Input: 4VDC/A Operational Voltage:.-0VDC Output: 4VDC/0A C F APPROVALS CONTROL EQUIPMENT 4KA U INDUSTRIAL LISTED F EN EN 008- Read installation instructions before connecting Figure 0 Figure 06 Figure 07 PHOENIX CONTACT page of 9

6 Uninterruptible Power Supply Unit for Universal Use AC QUINT-DC-UPS Power Supply Input Output QUINT-BAT/4DC Unbuffered Load DC + Buffered Load.4. Connection DC + The following cable cross sections can be connected: Solid [mm ] Stranded [mm ] AWG Torque [Nm] Input: Output: : Signal: l For reliable and safe-to-touch connections: Strip 0 mm (0.9 in.) from the input and output side connector ends and 7 mm (0.8 in.) from the signal connector ends. To maintain UL approvals, use copper cables, which are designed for operating temperatures > 7 C (67 F). To meet GL requirements, unused terminal compartments should be closed... Input (, Figure 4, Figure 8) The QUINT-DC-UPS is connected to the 4 V DC output of the power supply via the "Input +" and "Input -" terminal blocks. The output is isolated from the input by the internal diode. The stored power is only supplied to the output. The device is protected against overcurrent and short circuit by an internal input fuse. +4V 0,A DC 4 V 0 A Input Output Fuse Additional device protection is not required, as an internal fuse is present. QUINT DC-UPS 0 A DC DC + + R R Bat.- Bat.- Mode Charge R R Remote OFF ON 0, 0 0 0,4 7, Figure 08 Order-No.: Input: 4VDC/ Operational Voltage:.-0VD Output: 4VDC/0 APPROVALS U INDUSTRIAL LISTED CONTROL EQUIPMENT 4KA F Read insta before conn Figure 09 If the internal fuse is blown, this is most probably due to a device fault. In this case, the device should be checked in the factory. PHOENIX CONTACT page 6 of 9

7 Uninterruptible Power Supply Unit for Universal Use.6. Output All devices that must be supplied without interruption in the event of a supply voltage failure ("Buffered Load"), are connected to the "Output +" and "Output -" terminal blocks of the DC output (Fig. 8). It is recommended that all other loads, which do not require buffering ("Unbuffered Load"), are connected to the 4 V DC output of the power supply. This increases the buffer time, as this time depends on the output current (see Fig. 0). The internal diode ensures that the buffered loads are isolated from the unbuffered loads. Current [A] Ah 7. Ah.4 Ah Time [min.] Figure 0.7. Module The battery module is connected to the QUINT-DC-UPS via the " +" and " -" terminal blocks. To interrupt the charge/discharge current of the battery module, the " module selection" selector switch $ must be set to "". The fuse on the battery module must be removed when installing or replacing the battery module. The QUINT-DC-UPS is optimized for use with QUINT-BAT/4DC type battery modules. The following battery modules are recommended: QUINT-BAT/4DC/,4AH (Order No ) QUINT-BAT/4DC/7,AH (Order No. 866) QUINT-BAT/4DC/AH (Order No. 8666) Following successful installation, the capacity of the connected battery module must be selected using the " module selection" rotary switch $..8. Signaling Outputs The signal outputs are connected via terminal blocks // 4, // or // 6. The contacts are floating contacts. The plug-in bridge provided can be used to supply +4 V to grouped contacts,,. This means that N/C contacts,, and N/O contacts,, can be evaluated as switching outputs with 0 V and +4 V voltage levels. DC 4 V 0 A put Output Mode t.-charge 0, 0 0 0,4 7, Bat.-Mo $ AP UL Figure PHOENIX CONTACT page 7 of 9

8 Uninterruptible Power Supply Unit for Universal Use.9. Remote Shutdown ("Remote", Fig. ) The device has a UPS remote shutdown function for specific shutdown. Remote shutdown must be deactivated for the device to switch to buffer mode in the event of a supply voltage failure. 4 4 DC + + Remote Shutdown Off The "Remote shutdown R" and "Remote shutdown R" terminal points are short circuited (e.g., with a plug-in bridge) OR The "Remote shutdown R" terminal point is supplied with a 4 V DC voltage The QUINT-DC-UPS switches to buffer mode in the event of a supply voltage failure Remote Shutdown On The "Remote shutdown R" and "Remote shutdown R" terminal points are not connected All LEDs are off The QUINT-DC-UPS does not switch to buffer mode in the event of a supply voltage failure, instead the device is shut down. When the supply voltage is reapplied, the battery module is charged and the device remains off until remote shutdown is deactivated. Connected loads are supplied as long as the supply voltage is present 6. Setting Options on the Device (Fig. ) 6.. Buffer Time Setting Buffer mode can be exited after a predefined time has elapsed or by external shutdown (see 6.9). If the device is to be shut down after a specific time has elapsed, the time can be set via the selector switch on the front of the device. When the supply voltage is reapplied, the device can switch to buffer mode again. 6.. Module Setting Before startup, the capacity of the battery module used must be set on the device via the selector switch $. When replacing the battery, the selector switch must be set to "" (see also 6.7). V 0,A 0 A Output DC + + R R Bat.- Bat.- Mode Charge 0, R R Remote OFF ON 0 0 0,4 7, 8 Ala Charge $ Figure Figure QUI Orde Inpu Ope Outp APP U PHOENIX CONTACT page 8 of 9

9 Uninterruptible Power Supply Unit for Universal Use 7. Method of Operation In the event of a power failure at the output, the QUINT-DC-UPS supplies all connected devices with a 4 V DC voltage without interruption at a load current up to 0 A. When the 4 V supply voltage is applied, the connected battery module is charged. In the event of a supply voltage failure, the battery module is connected to the output, and the stored power ensures that all connected devices continue to operate without interruption. The professional signaling via function LEDs and floating PDT contacts enables reliable evaluation of all the main operating states. 7.. Output Voltage In normal operation, the QUINT-DC-UPS output voltage corresponds to the usual supply voltage. If the supply voltage drops more than V in the space of 0. seconds or falls below the minimum threshold of V, the device switches to buffer mode. If the output voltage drops below 0.4 V in buffer mode, this is indicated by the indicator. If the output voltage drops to 9. V because the battery module is flat, the device is shut down completely. When the supply voltage is reapplied, the device automatically switches on again. The device is electronically shortcircuit-proof and idling-proof. 7.. Signaling Three floating PDT contacts and three indicators are provided for function monitoring. Key/Indicators Green " Power IN Yellow Bat. Mode/Charge Red 0 Supply voltage, ON Flashing OFF battery module charging Supply voltage, ON OFF OFF battery module charged (normal operation) Buffer mode OFF ON OFF module flat OFF OFF ON - module quality test negative ON OFF ON - No battery module - - Buffer time elapsed - Remote shutdown activated OFF OFF OFF xx - xx: Contact closed, x, x Mode, x Charge x group contact, x N/C contact, x N/O contact Key/Output Supply voltage, battery module charging Supply voltage, battery module charged (normal operation) Bat. Charge Bat. Mode Buffer mode - - module flat module quality test negative No battery module - - Buffer time elapsed - Remote shutdown activated Temperature Response The charging rate of the connected battery module depends on the temperature Testing the Module A quality test is carried out on the battery module once a week and its presence is verified every minute. A negative test result is indicated by the indicator. PHOENIX CONTACT 0/0/0 TNR: PHOENIX CONTACT page 9 of 9

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40 Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/4DC/40. Short Description Uninterruptible Power Supply Units for Buffering Long-Term terruptions Saves space thanks to the compact, uniform

More information

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5 Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

QUINT-PS-3x AC/24DC/10

QUINT-PS-3x AC/24DC/10 3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1 Power Supply, Primary Switch Mode, arrow Design -PS-100-240AC/24/1 POWER provides: Extra narrow widths of 22.5, 45, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide range input A high

More information

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX

1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS AC/24DC/5/EX 1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas -PS-100-240AC/24/5/EX POWER provides: Preventive function monitoring through professional signaling Global use due to a

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents

More information

Extract from the online catalog

Extract from the online catalog Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

QUINT-PS AC/24DC/10

QUINT-PS AC/24DC/10 Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description Primaryswitched power supply unit Data sheet 105549_en_00 PHOENIX CONTACT 20130405 1 Description The UNO POWER power supply unit impresses in worldwide use thanks to maximum energy efficiency. Low noload

More information

Uninterruptible power supply - TRIO-UPS/1AC/24DC/

Uninterruptible power supply - TRIO-UPS/1AC/24DC/ Uninterruptible power supply with integrated power supply unit, 5A, in combination with MINI-BAT/24/DC/.3 AH, QUINT-BAT/24DC 3,4AH, 7,2AH or 2 AH Key commercial data Packing unit PCE GTIN Custom tariff

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Extract from the online catalog STEP-PS/1AC/24DC/2.5 Order No.: 2868651 DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Commercial data EAN 4046356163224 Pack 1 pcs. Customs tariff

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description. Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Power Supply HARTING pcon

Power Supply HARTING pcon HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)

More information

MINI MCR-SL-UI-REL(-SP)

MINI MCR-SL-UI-REL(-SP) Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.

More information

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description (-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 Extract from the online catalog QUINT-PS/24DC/48DC/ 5 Order No.: 2320128 QUINT DC/DC converter, primary-switched, input: 24 V DC, output: 48 V DC/5 A Commercial data GTIN (EAN) sales group Pack Catalog

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

Industrial Power Supplies

Industrial Power Supplies 50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) Data sheet Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range) The CP-B 24/20.0 serves to ensure a shortterm uninterrupted power supply

More information

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

PSR DC/ESP4/2X1/1X2

PSR DC/ESP4/2X1/1X2 PSR-...- 24DC/ESP4/2X1/1X2 Safety relay for emergency stop and safety door monitoring Data sheet 100516_en_05 PHOENIX CONTACT 2013-11-21 1 Description The safety relay can be used for emergency stop and

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

PSR-PS21. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106253_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

Industrial Power Supplies

Industrial Power Supplies 75-600 Watt Features Switch mode power supplies for DIN-rail mounting 4 power ranges with 3, 6, 12 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies

More information

QUINT-UPS/ 24DC/ 24DC/10

QUINT-UPS/ 24DC/ 24DC/10 Uninterruptible power supply INTERFACE Data sheet 104658_en_02 PHOENIX CONTACT 20151028 1 Description Uninterruptible power supplies (UPS) continue to deliver power even if the mains breaks down. An uninterruptible

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply Data sheet Power supply CP-E 48/1.25 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN Highlights & Features Full corrosion resistant Aluminium chassis Suitable for 24V system up to 40A Built-in diagnostic monitoring for DC OK, Discharge and Battery Fail by relay contacts LED indicator for

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control

More information

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply Data sheet Power supply CP-E 24/0.75 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

DX561 Digital Input/Output Module

DX561 Digital Input/Output Module Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI

More information

Messaging module CP-C MM

Messaging module CP-C MM 2CDC 271 087 F0t04 Features Pluggable onto CP C range primary switch mode power supplies REMOTE OFF input to switch off the power supply unit remotely Monitoring of the input voltage of the power supply

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Power supply CP-E 24/10.0 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply Data sheet Power supply CP-E 24/10.0 Primary switch mode power supply The CP-E range offers enhanced functionality while the number of different types has been considerably reduced. Now all power supply

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply Data sheet Power supply CP-D 12/2.1 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O Characteristics Star-Delta Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts

More information

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately

More information

AO561 Analog Output Module

AO561 Analog Output Module Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal

More information

DI561 Digital Input Module

DI561 Digital Input Module Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital

More information

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

PSR-PC20. SIL coupling relay. Data sheet. 1 Description SIL coupling relay Data sheet 106255_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The PSR-PC20 SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand

More information