SINGLE READER EXPANSION MODULE

Size: px
Start display at page:

Download "SINGLE READER EXPANSION MODULE"

Transcription

1 SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1

2 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader and door hardware. It also provides LED control and buzzer control. Two Form-C contact relay outputs may be used to control locking hardware. The two inputs provided can be used for monitoring door contacts and request to exit devices. Input circuits can be configured as unsupervised or supervised using end of line resistors. Communication to the Alarm.com Door Controller is accomplished using a 2-wire RS-485 interface. The ADC-ACX1 requires 12 to 24V DC for power. STATUS LEDs Ø0.156 [Ø4.0 mm] 0.20 [5.1 mm] TB4 K1 TB3 NC 2.75 [69.9 mm] 2.35 [59.7 mm] BZR LED CLR D1 DAT D0 VO TR+ U1 K2 C NO NO NC C VIN GMD K1 K2 TB B A TB [5.1 mm] 3.85 [97.8 mm] 4.25 [108 mm] TAMPER INPUT NORMALLY OPEN SWITCH

3 Wiring CONNECTIONS TB1-1 TR+ TB1-2 TR- RS-485 Bus TB1-3 TB2-1 VIN Input Power TB2-2 Input Power Ground TB2-3 TB2-4 I2 I2 Input 2 TB2-5 TB2-6 I1 I1 Input 1 TB3-1 NC Relay K1 - Normally Closed Contact TB3-2 C Relay K1 - Common Contact TB3-3 NO Relay K1 - Normally Open Contact TB3-4 NO Relay K2 - Normall Open Contact TB3-5 NC Relay K2 - Normally Closed Contact TB3-6 C Relay K2 - Common Contact TB4-1 Reader Ground TB4-2 BZR Reader Buzzer Output TB4-3 LED Reader LED Output TB4-4 CLK/D1 Reader CLK/Data 1 TB4-5 DAT/D0 Reader DAT/Data 0 TB4-6 VO Reader Power Output 2 Single Reader Expansion Module

4 Status LEDs Power-up: All LEDs OFF Initialization: Once power is applied, initialization of the module begins The A LED is turned ON at the beginning of initialization Run time: After a successful initialization, the LEDs have the following meanings: A LED: Heartbeat and On-Line Status: Off-line: 1 second rate, 20% ON On-line: 1 second rate, 80% ON A LED Error Indication: Waiting for application firmware to be downloaded: 0.1 s ON, 0.1 s OFF B LED: Communication Port Status: Indicates communication activity on the communication port Communication Wiring The ADC-ACX1 communicates to an Alarm.com door controller using a multi-drop 2-wire RS-485 interface. The total cable length is limited to 2,000 feet (609 meters). Shielded cable of 24 AWG with characteristic impedance of 120 ohm is specified for the 2-wire RS- 485 interface. If the ADC-AX1 is the last device on the communication bus, jumper J4 must be installed. ADC-ACX1 Installation Guide 3

5 RS-485 Wiring using the ADC-ACC1-17 Door Controller UP TO EIGHT TOTAL EXPANSION MODULES MAY BE WIRED. THE LAST EXPANSION MODULE ON THE BUS MUST HAVE JUMPER J5 INSTALLED FOR ADC-ACX2 MODULES AND J4 INSTALLED FOR ADC-ACX1 MODULES. USE TWISTED PAIR 24 AWG, 120 OHM IMPEDANCE CABLE WITH DRAIN AND SHIELD WIRES. 2,000 FT. (609 M) MAXIMUM TOTAL LENGTH. TR+ TR- TR+ TR- TR+ TR- ADC-ACX1 OR ADC-ACX2 ADC-ACX1 OR ADC-ACX2 CLK DAT ADC-ACC1-17 For ease of install, daisy chain expansion modules together. Wire each expansion module to the next module instead of wiring directly back to the controller. 4 Single Reader Expansion Module

6 Addressing Install the jumpers on the ADC-ACX1 expansion module according to the "Jumpers/Switches ON" column in the Access Control Devices table on the Alarm.com Dealer Website. These jumpers are also displayed in the "Add Expansion Module" installation wizard. If these jumpers are not installed according to the website, the device and its connected reader and door hardware will not function properly with Alarm.com. Reader Wiring The reader port supports a one Wiegand reader. Readers with power requirements different from the input voltage used for the ADC-ACX1 board must be powered separately.22 AWG minimum recommended for readers. Typical Reader Wiring 1 TB4 BZR LED D1/CLK D0/DAT VO The input power is passed through to the reader terminal strip and is available for powering a reader. Care must be taken to ensure that the input voltage is within the voltage range of the reader. The reader power output terminal, TB4-6 (VO), is not current limited. ADC-ACX1 Installation Guide 5

7 Relay Wiring Two Form-C contact relays are provided for controlling door lock mechanisms. Each relay has a Common pole (C), a Normally Open pole (NO), and a Normally Closed pole (NC). When momentarily delivering power to unlock the locking hardware (fail secure), the Normally Open and Common poles are used. When momentarily removing power to unlock the locking hardware (fail safe), the Normally Closed and Common poles are used. Check with local building codes for proper egress door installation. 18 AWG minimum recommended for electric locking hardware. The current ratings are 5 A for relay K1 and 1 A for relay K2. Load switching can cause abnormal contact wear and premature contact failure. Switching of inductive loads (strike) also causes EMI (electromagnetic interference), which may interfere with normal operation of other equipment. To minimize premature contact failure and to increase system reliability, a contact protection circuit may be used. The following circuit is recommended. Locate the protection circuit as close to the load as possible (within 12 inches [30 cm]), as the effectiveness of the circuit will decrease if it is located far away. Typical DC Door Strike Wiring FUSE TO DC POWER SOURCE DIODE DC STRIKE DIODE SELECTION Diode current rating: 1x strike current Diode breakdown voltage: 4x strike voltage For 12V DC or 24V DC strike, diode 1N4002 (100V/1A) typical 6 Single Reader Expansion Module

8 Input Wiring There are 8 inputs that are typically used to monitor door position or request to exit devices. Input circuits can be configured as Unsupervised (2 states); reporting as open or closed contact, or Supervised (6 states); reporting as open or closed contact, open circuit, shorted circuit, grounded circuit *, or foreign voltage*. A supervised input circuit requires adding two resistors with value of 1k ohm, 1% to the circuit to facilitate proper reporting and should be located as close to the sensor as possible. * Grounded and foreign voltage states are not a requirement of UL 294 and therefore not verified by UL. The input circuit wiring configurations shown are supported but may not be typical. 22 AWG minimum required for input wiring. 18 AWG recommended if wiring request-to-exit devices in series with locking hardware. Standard Supervised Circuit, Normally Closed Contact Standard Supervised Circuit, Normally Open Contact Unsupervised Circuit, Normally Closed Contact 1K,1% 1K,1% 1K,1% 1K,1% IN1 IN2 IN3 IN4 Unsupervised Circuit, Normally Open Contact ADC-ACX1 Installation Guide 7

9 Specifications The Expansion Module is for use in low voltage, class 2 circuits only. INPUT POWER 12/24V DC, 150mA max. 110mA 12V 60mA 24V OUTPUT POWER Input voltage pass-through COMMUNICATION 2-Wire RS-485 INPUTS One dedicated reader input Two programmable inputs One dedicated tamper input OUTPUTS Two relay outputs 30V DC, 30V DC) Single-wire LED control Single-wire buzzer output CERTIFICATIONS UL 294 recognized CE compliant RoHS DIMENSIONS (L X W X H) 2.75 x 4.25 x 1.0 (70 x 108 x 25.4 mm) TEMPERATURE F ( C) operational F ( C) storage OPERATING HUMIDITY 0-95% (non-condensing) RH 8 Single Reader Expansion Module

10 WARRANTY Mercury Security warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment. Mercury Security assumes no responsibility for products damaged by improper handling or installation. This warranty is limited to the repair or replacement of the defective unit. There are no expressed warranties other than set forth herein. Mercury Security does not make, nor intends, nor does it authorize any agent or representative to make any other warranties, or implied warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose. Returns must be accompanied by a Return Material Authorization (RMA) number obtained from customer service, and prepaid postage and insurance. LIABILITY The Interface should only be used to control exits from areas where an alternative method for exit is available. This product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or malfunction of the product. Mercury Security s liability does not extend beyond the purchase price of the product. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

11 2018 Alarm.com. All rights reserved Greensboro Drive, Suite 100 Tysons, VA

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

MR50 READER INTERFACE

MR50 READER INTERFACE 2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device

More information

MR51e Reader Interface

MR51e Reader Interface J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA

More information

EP1501 Intelligent Controller

EP1501 Intelligent Controller J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.

More information

MRDT Display Terminal

MRDT Display Terminal www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205 MRDT Display Terminal Installation and Specifications: This device complies with part 15 of the FCC

More information

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

CYPRESS   EXP SPX Expansion interface! modules EXP-2000_MAN_0314 CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

USB 3.0 Spectra

USB 3.0 Spectra USB 3.0 Spectra 3001-15 1-Port USB 3.0 15m Active Extension Cable User Guide Thank you for purchasing the Icron USB 3.0 Spectra 3001-15. Please read this guide thoroughly. This document applies to Part

More information

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A www.supremainc.com INSTALLATION GUIDE DM-20 English Version 1.10 EN 101.00.DM20 V1.10A Contents Safety Instructions... 3 Components... 4 Front Side... 5 Installation Example... 6 Dimensions... 7 Installation...

More information

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by USB Ranger 2212 Cat 5 USB 2.0 Extender with Remote Power User Guide Powered by Thank you for purchasing the USB Ranger 2212. Please read this guide thoroughly. This document applies to Part Numbers: 00-00252,

More information

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board *P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,

More information

clarity 3 Programmable Controller

clarity 3 Programmable Controller clarity 3 Programmable Controller BACnet General Purpose Controllers (B-AAC) DESCRIPTION Taco Clarity 3 FPC series controllers are designed to control building systems and HVAC equipment. The integrated

More information

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide USB 2.0 Ranger 2304 4-Port USB 2.0 100m CAT 5e/6/7 Extender System User Guide Thank you for purchasing the USB 2.0 Ranger 2304. Please read this guide thoroughly. This document applies to Part Numbers:

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

USB Ranger 110/410 User Guide

USB Ranger 110/410 User Guide USB Ranger 110/410 User Guide Featuring ExtremeUSB Technology USB Ranger 110/410 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after October 2014 Kernel Version: 6.15 Document Revision: 3 QuickServer

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

USB Ranger Fiber Optic USB 2.0 Extender. User Guide USB Ranger 2224 Fiber Optic USB 2.0 Extender User Guide Thank you for purchasing the USB Ranger 2224. Please read this guide thoroughly. This document applies to Part Numbers: 00-00260, 00-00261, 00-00262,

More information

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver) Keri NXT controllers with Mercury firmware now provide an Entrance/Exit door control feature. This Entrance/Exit feature allows two readers to be wired to one bus on the NXT controller to control entrance

More information

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide USB 2.0 Ranger 2304 4-Port USB 2.0 100m Cat 5e Extender System User Guide Thank you for purchasing the USB 2.0 Ranger 2304. Please read this guide thoroughly. This document applies to Part Numbers: 00-00347,

More information

ACLD Channel Opto-isolated Digital Input Board

ACLD Channel Opto-isolated Digital Input Board ACLD-9182 16 Channel Opto-isolated Digital Input Board @ Copyright 1996 All Rights Reserved. Manual edition 01, January 1996 The information in this document is subject to change without prior notice in

More information

Installation guide for PR302 v2.0 Rev. E

Installation guide for PR302 v2.0 Rev. E Installation guide for PR302 v2.0 Rev. E 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document is subject to the Terms of Use in their current version published at the www.roger.pl website of

More information

USB Ranger 422 User Guide

USB Ranger 422 User Guide USB Ranger 422 User Guide Featuring ExtremeUSB Technology USB Ranger 422 Thank you for purchasing the USB Ranger. Please read this guide thoroughly before installation. This document applies to Part Numbers:

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module

More information

SR10k Mag-Stripe Access System Users Guide

SR10k Mag-Stripe Access System Users Guide www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562) 986-9105 FAX (562) 986-9205 SR10k Mag-Stripe Access System Users Guide Mercury Security 2013 SR10k Doc. 10107-0007 Rev 1.08

More information

OP8/16 Optoisolated Digital Input Board User's Manual

OP8/16 Optoisolated Digital Input Board User's Manual OP8/16 Optoisolated Digital Input Board User's Manual Real Time Devices USA, Inc. Accessing the Analog World Publication No. OP16-9742 OP8/16 User's Manual REAL TIME DEVICES USA 820 North University Drive

More information

Magnetic Card Reader. Contents

Magnetic Card Reader. Contents 23884539 Magnetic Card Reader Models SMR-10 and SMR-20 Installation and Maintenance Instructions Contents General...1 Mounting the Reader...1 Reader Wiring...1 Connecting the Keypad...2 Weather-Proofing

More information

PRO2200 Professional Modular Access Control Hardware

PRO2200 Professional Modular Access Control Hardware PRO2200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO2200 professional modular access control hardware is an advanced access control panel capable of providing

More information

American Power Design, Inc.

American Power Design, Inc. American Power Design, Inc. FEATURES Customer Selects Output Voltage Single Outputs to + or - 12000 Vdc Dual Outputs to +/- 3000 Vdc High Reliability Industry Standard Pinouts Wide Temperature Range (-20

More information

PR602LCD v1.0 Installer Manual Rev. A

PR602LCD v1.0 Installer Manual Rev. A PR602LCD v1.0 Installer Manual Rev. A Introduction This document contents minimum information required for electrical connections and installation of the PR602LCD access controller in Roger Access Control

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

Integrated Stepper Drive & Motor

Integrated Stepper Drive & Motor SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide AC-225 Advanced Scalable Networked Access Controller Hardware Installation and User Guide July 2007 Table of Contents Table of Contents 1. Introduction... 3 1.1 Features...5 1.2 VeriTrax AS-225...5 2.

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

8 channel universal input and 4 channel Form C digital output

8 channel universal input and 4 channel Form C digital output 1 I/O Modules UI-8/DO-FC-4 and UI-8/DO-FC-4-H 8 channel universal input and 4 channel Form C digital output Introduction The UI-8/DO-FC-4 and UI-8/DO-FC-4-H are universal input, 8 channel and digital output,

More information

Mercury Installation Manual

Mercury Installation Manual This document is a guide to successful integration of Mercury panels with Brivo Onair in two steps: a set of pre-installation procedures and associating the panel with Onair. If you have Mercury panels

More information

V-9964 Digital Feedback Eliminator/Message Stacker

V-9964 Digital Feedback Eliminator/Message Stacker Issue V-99 Digital Feedback Eliminator/Message Stacker General Design The V-99 is designed to eliminate acoustic feedback and act as a message stacker. When a page is made, the message is digitized and

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

PRO3200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing

More information

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground. NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe

More information

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-18s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-18s expansion module is used with the X-600M controller. The X-18s has ten, high-current

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after January 2015 Kernel Version: Application Version: Document

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

Proximity Card and Pin Reader Installation Manual

Proximity Card and Pin Reader Installation Manual Multi Prox Proximity Card and Pin Reader Installation Manual PUBLICATION INFORMATION 60A9 - Draft Release Version 0.1.2 71D0 - Version 1.0.5 CONTENTS Introduction... 1 Legend... 2 Terminology... 2 Mounting...

More information

V-9908 MESSAGE/PAGE PANEL

V-9908 MESSAGE/PAGE PANEL Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides

More information

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN Copyright 2018 by Rosslare. All rights reserved. This

More information

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev. CI-1 and CI-8 Communications Interface 5452 Betsy Ross Drive Santa Clara, CA 95054-1184 (408) 727-5170 FAX (408) 727-6707 P/N 66104700001 Rev. F r 1997 Westinghouse Security Electronics. All rights reserved.

More information

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811 95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing

More information

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code: INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation

More information

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815 95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing

More information

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide USB 3.0 Spectra 3022 2-Port USB 3.0 100m Multimode Fiber Extender System User Guide Thank you for purchasing the USB 3.0 Spectra 3022. Please read this guide thoroughly. This document applies to Part Numbers:

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

EL5353 DVI + USB 2.0 Extender DVI and USB m CAT 5e/6/7 KVM Extender System. User Guide

EL5353 DVI + USB 2.0 Extender DVI and USB m CAT 5e/6/7 KVM Extender System. User Guide EL5353 DVI + USB 2.0 Extender DVI and USB 2.0 100m CAT 5e/6/7 KVM Extender System User Guide Thank you for purchasing the EL5353 KVM Extender. Please read this guide thoroughly. This document applies to

More information

WR-5e Remote Control

WR-5e Remote Control 1. Introduction WR-5e Remote Control The WR-5e is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and ne4800

More information

USB 2.0 Ranger High Speed Extender System. User Guide

USB 2.0 Ranger High Speed Extender System. User Guide USB 2.0 Ranger 2101 High Speed Extender System User Guide Powered by ExtremeUSB Thank you for purchasing the Ranger 2101. Please read this guide thoroughly. This document applies to Part Numbers: 00-00231

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

CAN Fiber Optic Modem

CAN Fiber Optic Modem User Manual for the HE200CFM100 CAN Fiber Optic Modem Second Edition 17 September 1999 MAN0007-02 PREFACE 17 SEPT 1999 PAGE 3 PREFACE This manual explains how to use the Horner APG s CAN Fiber Optic Modem.

More information

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide EL5200 HDMI + USB 2.0 Extender HDMI and USB 2.0 100m Cat 5e KVM Extender System User Guide Thank you for purchasing the EL5200 KVM Extender. Please read this guide thoroughly. FCC Radio Frequency Interference

More information

PGR-3200 MANUAL INSULATION MONITOR

PGR-3200 MANUAL INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN

More information

PCLD-8751 PCLD User Manual

PCLD-8751 PCLD User Manual PCLD-8751 48-Channel Opto-isolated D/I Board PCLD-8761 24-Channel Opto-isolated D/I and 24-Channel Relay Board User Manual Copyright The documentation and the software included with this product are copyrighted

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models: AC-225x-B Series Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual Models: AC-225-Bx AC-225-DIN AC-225IP-Bx AC-225IP-DIN Copyright 2018 by Rosslare. All rights reserved. This

More information

Bluetooth USB Adapter TALUS. User Guide

Bluetooth USB Adapter TALUS. User Guide Bluetooth USB Adapter TALUS User Guide Revision 0.1 1 User Guide for the TALUS Revision 1.0.1 Firmware version 1.0.X Printed in Korea Copyright Copyright 2008, SystemBase Co., Ltd. All rights reserved.

More information

USB 400 FO. EXT-USB-400FON. User Manual

USB 400 FO.   EXT-USB-400FON. User Manual USB 400 FO EXT-USB-400FON User Manual www.gefen.com Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM PST Monday thru Friday, Pacific

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide FX-2 Control Board ASY-360-XXX Setup and Configuration Guide Micro Air Corporation Phone (609) 259-2636 124 Route 526. WWW.Microair.net Allentown NJ 08501 Fax (609) 259-6601 Table of Contents Introduction...

More information

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction User's Guide 1/16 th DIN ph Controller Model 48PH2 Introduction Thank you for selecting the Extech Model 48PH2 controller. This 1/16 th DIN-size controller offers dual display, high resolution measurements,

More information

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL M-SWITCH SWITCH INPUT IN GAS CTROL SYSTEM INSTALLATI OPERATI AND MAINTENANCE MANUAL QUATROSENSE ENVIRMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMD, TARIO CANADA K0A 2Z0 PHE: (613) 838-4005 FAX: (613)

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

USB Server User Manual

USB Server User Manual 1 Copyright Notice Copyright Incorporated 2009. All rights reserved. Disclaimer Incorporated shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

Ashly WR-5 Remote Control

Ashly WR-5 Remote Control 1. Introduction Ashly WR-5 Remote Control The WR-5 is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

0DQXIDFWXULQJ $FFHVV &RQWURO VLQFH

0DQXIDFWXULQJ $FFHVV &RQWURO VLQFH cdvigroup.com Copyright (C) 2011 CDVI. All rights reserved. ATRIUM Access Control is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this product, or

More information

232iLM Keypad Installation and Programming Instructions

232iLM Keypad Installation and Programming Instructions 232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.

More information

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount Fiber-Optic Link to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount 101-0079 Installation Operation & Specifications Manual Auto-direcon control Supports BAUD rates up to 115,200 Fiber

More information

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION ( ) LIGHTING CONTROL PANELBOARD (26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting

More information

Installation Operation & Specifications Manual. General Description

Installation Operation & Specifications Manual. General Description 101-0020 USB to 2-Wire RS-485 Converter Installation Operation & Specifications Manual General Description The 101-0020 USB to RS-485 converter provides a simple, low cost interface between a PC or laptop

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998 SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

PR402 v2.0 Installer Manual Rev.C

PR402 v2.0 Installer Manual Rev.C PR402 v2.0 Installer Manual Rev.C Introduction This document contents minimum information required for electrical connections, installation and initial tests of PR402 access controller. Installation The

More information

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual AMAX-2750SY Series 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules User Manual Copyright The documentation and the software included with this product are copyrighted 2008 by Advantech Co., Ltd.

More information

American Power Design, Inc.

American Power Design, Inc. FEATURES 4 Customer Selects Output 4 Single Outputs to or 6000 Vdc 4 Dual Outputs to / 3000 Vdc 4 High Reliability 4 Industry Standard Pinouts 4 Wide Temperature Range (20 to 85 C) 4 60 khz Switching Frequency

More information

User Manual ADAM-6100EI Series. EtherNet/IP I/O Modules

User Manual ADAM-6100EI Series. EtherNet/IP I/O Modules User Manual ADAM-6100EI Series EtherNet/IP I/O Modules Copyright The documentation and the software included with this product are copyrighted 2009 by Advantech Co., Ltd. All rights are reserved. Advantech

More information

Inventronics LED Driver 0 10V DMX RDM

Inventronics LED Driver 0 10V DMX RDM Features Converts DMX Signal to 0-10V Dimming Signal Complies with both DMX RDM and Traditional DMX Networks Use Driver Dim-to-Off Capability to Eliminate AC Switch or Relay Powered by 12Vdc with Simple

More information