DRIVEGUARD ULTRA TM INSTALLATION/OPERATION MANUAL

Size: px
Start display at page:

Download "DRIVEGUARD ULTRA TM INSTALLATION/OPERATION MANUAL"

Transcription

1 DRIVEGUARD ULTRA TM INSTALLATION/OPERATION MANUAL Features of the DRIVEGUARD ULTRA TM Driveway System: Advanced lightning protection Sensor probe supervision Accommodates 100 sensor probes Transient suppressor reduces false alarms Improved RFI immunity Adjustable exit delay (50 seconds to 15 minutes) Adjustable re-trigger hold-off (1 second to 2½ minutes) Adjustable annunciator time with extra annunciator form C relay contacts (½ second to 30 seconds) Adjustable floodlight relay entry delay time (1 second to 2½ minutes) Adjustable floodlight relay time (15 seconds to 15 minutes) Built-in battery charger allows annunciation during power outage (battery not included) Manual trip-test button Floodlight N.O. relay contact rating is 15 amps at 125 VAC Floodlight relay can be used to switch on up to 1800 watts of lights Floodlight relay can be used to operate coil of multi-contact relay or contactor and thus operate many banks of lights Floodlight relay can be used to switch low voltage devices such as line carrier interface modules Photocell daytime lockout keeps lights from coming on during daylight hours Adjustable photocell sensitivity Automatic increase of floodlight relay time when additional vehicles are detected Instant-On feature when floodlight timer is activated by the manual button on the CT-A1 annunciator plate Floodlight timer instant reset on the CT-A1 annunciator plate CONSUMER INFORMATION: DATE PURCHASED: DATE INSTALLED: SERIAL NUMBER: (Located on black relay on circuit board) Manufactured by

2 TABLE OF CONTENTS Introduction... 1 Serial Number... 1 Location of Control Unit... 1 Floodlight Relay Wires... 1 Installing Control Unit... 1 Power and Battery Backup... 2 Earth Ground... 3 Trip-Test Button... 3 Extra Set of Relay Contacts... 3 Integrating With a Security or Home Automation Panel... 3 CT-6 Probe and Wire Check-out... 3 System and Probe Don'ts... 4 Location of CT-6 Probe... 4 Installing CT-6 Probe and Cable... 5 Connecting CT-6 Probe to Control Unit... 6 Multi-Probe Assemblies... 6 Phasing Probes... 6 Probe System Supervision... 6 Using Probe Fault Mode for Testing... 6 SD-6 Short Driveway Probe System... 7 Connecting Other Sensing Devices to Control Unit... 7 Installing Photocell Block... 7 Installing Sounders (Annunciators)... 7 Adjusting CT-A1 Exit Delay... 9 Adjusting Sounder (Annunciator) Time Adjusting Re-Trigger Hold-Off Adjusting Floodlight Entry Delay Time Adjusting Floodlight Time Adjusting Photocell Sensitivity Adjusting Probe Sensitivity Adjusting Transient Suppressor Field Troubleshooting Splicing Probe Cable Warranty Information Merchandise Return Information Technical Specifications Copyright 2018 by Cartell

3 DRIVEGUARD ULTRA TM SYSTEM MANUAL INTRODUCTION Thank you and congratulations on purchasing the most professional vehicle detection system available! It has been manufactured to give years of trouble-free service. However, if it should need servicing, please consult the dealer/installer who installed your system. Read these instructions completely. Each system should be bench-tested by the dealer/installer before installation. The installer should become acquainted with the CF-2C control unit and sensor probe in the shop; make all adjustments and settings; and study all system functions. If there are any questions or problems that need to be discussed, contact the technical staff by calling our 800 number. SPECIAL NOTE: Look for information gleaned from the field contained under the heading SPECIAL NOTE throughout this manual (see Field Troubleshooting on page 11 for a complete list of them). SERIAL NUMBER: Attached to the relay on the circuit board is a sticker with a set of numbers and letters. This series of numbers and letters reveals the specific unit, its year of manufacture, its issue number, and ends with the serial number (see illustration). When calling Cartell for technical help, please have these numbers handy so your call may be handled in a timely manner. LOCATION OF CONTROL UNIT Install the control unit in a dry, weatherproof building away from heavy electrical motors, radio transmitters, main power service, or any equipment that may introduce electrical or R. F. noise. Install control unit in a sealed box when used in a corrosive atmosphere such as an animal barn or chemical plant. Install in a sealed, weather-proof box when installed outside. The weatherproof box must have a thermostatically controlled light bulb or heater to maintain temperatures above freezing. Drastic changes in temperature cause condensation on the board and will make the unit malfunction. FLOODLIGHT RELAY WIRES On the CF-2C circuit board is a floodlight relay (normally open, dry contact) rated 15 amps at 115 VAC. Two 12 gauge, black wires connected to this relay exit out the back of the CF-2C case. This floodlight relay can be used to operate three types of systems: 1. The relay can be used to operate up to 1800 watts directly (see Figures 1A, 1B, and 1C and Installing Control Unit next page). 2. The relay can be used to operate the coil of an auxiliary relay or contactor to power banks of lights (see Installing Control Unit below). 3. The relay can be used to activate low voltage lighting up to 15 amps maximum. INSTALLING CONTROL UNIT See Figure 1, top of next page. Install a single-gang electrical box in the wall behind the control unit so that the black wires from the unit go directly into the electrical box. With the power to the floodlight switching system off, run a 14-gauge, two-wire Romex cable from the new single-gang electrical box to the existing floodlight switching system as shown in Figure 1A. Connect the Romex cable across the switch of a single-switch system as shown in Figure 1B. 1

4 Figure 1 CF-2C HOOK-UP SINGLE SWITCH MULTIPLE SWITCH Figure 1A Figure 1B Figure 1C Connect the Romex cable across the "A" and "B" screw terminals of any switch in a multiple-switch system as shown in Figure 1C. Connect the black leads from the control unit to the two wires of the Romex cable with wire nuts as shown in Figure 1A. Mount the control unit to the wall over the electrical box as shown. Figure 2 POWER AND BATTERY BACKUP See Figure 2. The control unit operates on 12 VAC or 12 VDC. Connect the 12 VAC transformer between terminals No. 1 and 2 as shown in Figure 2 (NOTE: DO NOT connect a DC power source to terminals 1 and 2). A built-in battery charger will keep a 12 volt sealed lead-acid battery (not included) charged for operating the sounder Sonalert during power failure. NOTE: The battery back-up is not needed for normal operation of the CF-2C control. If you choose to purchase a battery, only a sealed lead acid (starved, wet-cell) battery should be used. DO NOT use a gelled-electrolyte battery. Recommended batteries are made by Yuasa Battery, Inc.; Gates Energy Products, Inc.; Eagle Picher Industries, Inc.; Panasonic Industries, Co.; or G.S. Battery, Inc. The positive (RED) lead connected to terminal No. 4 and the negative (BLACK) lead connected to terminal No. 5 are provided for connections to the battery. When an outside DC power source is being used, connect to these terminals in place of a battery. SPECIAL NOTE: During initial power-up or power-down and power-up sequence, the Exit Delay timer is automatically activated. Be patient, for the CF-2C control cannot be accessed until the Exit Delay timer times out. It is recommended that when the control unit is first installed that the Exit Delay adjustment (potentiometer C ) be set at minimum (fully counter-clockwise) until the system is operational. (See Adjusting CT-A1 Exit Delay on page 9.) 2

5 EARTH-GROUND See Figure 2 on page 2. A proper earth-ground is essential. A proper earth-ground is established by using an 8 foot copper or copper-clad ground rod driven deeply into the earth. Use a ground wire of at least 12 gauge. Solder wire to ground rod and then clamp it. Tin the other end of the ground wire and connect it to terminal No. 3 on the control unit. SPECIAL NOTE: A galvanized ground rod will not give this system a proper ground. Use copper-clad. TRIP-TEST BUTTON The trip-test button, located center right on the circuit board, is a tool to evaluate most of the control electronics and to help in setting the relay time. To test the control unit, a working probe must be attached to terminals No. 17, 18, and 19 (see Figure 2 on page 2). If the probe is disabled or not connected, simply connect a ohm resistor between the probe terminals No. 17 and 19. NOTE: The TRIP TEST button will not work if the PROBE FAULT LED is lit (this indicates a disabled probe). Set the probe sensitivity potentiometer "G" to the halfway point, i.e., vertically up and down (see Figure 6 on page 10). Push the TRIP-TEST button on and off quickly. DO NOT hold the button on. The signal generated simulates that of a detected vehicle. No response indicates component failure on the circuit board or failure of the power supply. It may be that the EXIT DELAY timer has not timed out as well (the EXIT DELAY time may have been preset anywhere between 50 seconds and 15 minutes (see Adjusting CT-A1 Exit Delay on page 9). EXTRA SET OF RELAY CONTACTS The annunciator relay has a second set of Form C relay contacts on terminals No. 11, 12, and 13. These contacts may be used to trip an alarm panel, trip a dialer, trip a line carrier interface, trigger a transmitter or trip a door bell. Potentiometer F controls the relay time of these contacts. INTEGRATING WITH A SECURITY OR HOME AUTOMATION PANEL See Figure 2 on page 2. The CF-2C has a floating, dry relay contact that can be used in conjunction with any security or home automation (H. A.) system. Two things will help you have a successful installation: 1. The manual for your home automation or security panel 2. A resistor, if required (security or H.A. system manual will tell you if a resistor is required) Note: Use the power supply that came with the CF-2C to power it rather than relying on the H.A. or security panel for power. Hook the CF-2C to two zone inputs on your security or H.A panel. If your system s contacts are normally closed, use terminals 11 & 12 on the CF-2C. At your system s panel, place a resistor (if required) between the terminals in parallel (see system manual for correct resistor size). If your security or H.A. contacts are normally open, use terminals 12 & 13 on the CF-2C and place a resistor (if required) between the terminals in series (see system manual for correct resistor size). CT-6 PROBE AND WIRE CHECK-OUT It is advisable to check the CT-6 probe assembly before and after installation in the earth. Use a good multimeter. With the probe wire disconnected from the control unit, measure the resistance between the RED and BLACK leads. It should read between 500 and 800 ohms for a single probe. Additional probes on the system will add approximately 620 ohms each. The reading should be stable with zero fluctuations. 3

6 The resistance between the RED lead and the SHIELD (bare wire), or the BLACK lead and the SHIELD should be millions of ohms. The resistance between the SHIELD drain wire and earthground should be millions of ohms. While making measurements to the shield drain wire, do not touch the bare wire or the mulitmeter leads with your fingers as that will spoil the readings. SPECIAL NOTE: On an existing installation, if a bad probe is indicated, it may be wire damage, lightning damage to the probe, or an improper splice. An open between all three wires usually indicates lightning damage to the probe. Dig up the probe and cut the cable several feet from the probe and test the probe. A damaged probe can be replaced by splicing a probe with a short lead on to the existing wire (see Splicing Probe Cable on page 12.) Leakage between the three wires may indicate wire damage. Leakage from RED or BLACK wires to the SHIELD (bare) wire may indicate wire damage. Erratic resistance readings may indicate an improper wire splice. SYSTEM AND PROBE DON'TS DO NOT use double sided tape to mount the circuit board on another surface, if you should decide to take the circuit board out of its case (not advisable). DO NOT bury the probe within 6 to 10 feet of a buried power or telephone line. DO NOT bury the probe within 6 to 10 feet of a buried invisible dog fence. DO NOT bury the probe within 10 feet of a natural gas line. DO NOT bury the probe within 20 feet of a power pole with a transformer attached to it. DO NOT bury the probe within 100 feet of railroad traffic. DO NOT bury the probe within 200 feet of sub-station type overhead power lines. DO NOT mount the probe vertically when used for above-ground applications. LOCATION OF THE CT-6 PROBE Figure 3 See Figure 3. The sensing range of a probe buried beside the driveway is 5 to 8 feet with a small car going 5 MPH. Taking the width of the car and the sensing range, this system covers a 12 foot wide driveway. Buried in the middle of the driveway, this system can cover up to a 24 foot wide driveway (see "Installing CT-6 Probe and Cable," p. 5). The probe should be at least 35 feet back from a street on which cross traffic is going under 35 MPH and at least 50 feet back from a street on which cross traffic is going over 35 MPH. If the probe is installed in the center of a 12 foot wide driveway, it can be 20 feet or 35 feet back from traffic 4

7 respectively. (You must adjust the probe's sensitivity (GAIN). See "Adjusting Probe Sensitivity" on page 11.) Stationary steel near the probe, but not over the probe, will not affect its operation. The probe can be placed in a PVC pipe under the steel-reinforced grid of a concrete roadway without affecting its operation. Probes installed above ground should be mounted no higher than 2 feet above the road surface. If the probe is attached to a wall or post, it should be mounted parallel to the ground and parallel with the driveway. Rule of thumb: the vehicle must approach one end of the probe, not both at the same time. If a car approaches both ends of the probe simultaneously (i.e., it is installed across, and not parallel with, approaching traffic) the signal will be cancelled. In drive-up window applications, install the probe at least 15 to 20 feet before the window. INSTALLING CT-6 PROBE AND CABLE See Figure 3 on page 4. Typically, the probe is buried 6-10 inches below ground, beside, and parallel to, the driveway. It is advisable to bury 6-10 feet of extra cable with the probe (coiled up) for future maintenance or relocation. When installing the probe in existing pavement, bore a 1.5 inch diameter hole vertically, 18 inches deep. Slice the pavement from the bored hole to the driveway edge to accommodate the cable. Install the probe and cable and seal with silicon. When installing the probe within a dirt or gravel driveway, first bury a 2 inch schedule 80 PVC pipe in the center of the driveway, 6-8 inches deep, and diagonally at a 45 degree angle (see Figure 3 on page 4). Slide the probe and cable to the end of this pipe. This will make it easily retrievable in the future. When installing in new construction, bury the 2 inch PVC pipe under the driveway as described above. Then pour cement or asphalt the drive. Insert the probe and cable after landscaping is complete to prevent possible damage to the cable. The probe cable is direct burial and does not require conduit. Depth of burial depends on lawn conditions. In cultured grass, bury the cable 2-3 inches deep. The root system of the grass will capture the cable for life. Use a lawn edger to slice a 1/4 inch wide trench across the lawn to the location of the control unit. Push the cable to the bottom of the slice, fill, and tamp. In uncultured field grass or in soil without cultured grass, bury the cable at least 6-8 inches deep. When installing the cable through woods or above ground, run it in PVC pipe for mechanical protection, as animals will chew through the cable if it is exposed. When pulling the cable through conduit or PVC pipe, it is important that every inch of cable be liberally lubricated. Use a wire lubricant, and pull only 100 feet or less at one time. The cable is coated with polyurethane and therefore has extremely high traction. This can cause a tremendous drag when not lubricated; enough to inconspicuously snap wires inside the rubber casing. Therefore, make sure you lubricate it when pulling it through non-magnetic conduit or PVC pipe. Also, the polyurethane coating on the probe cable demands that extreme care be taken when unrolling it. To unroll, put your arm through the center of the roll, remove the tape, and unravel the roll one wrap at a time. Once you begin unrolling the cable, do not lay it down before you are finished or it could become irreparably tangled. Note: Because the cable is fully shielded, it can be buried in the same trench (but not the same conduit) in which there are water, power and telephone lines, if codes permit. Check all electrical codes, both locally and nationally. 5

8 CONNECTING CT-6 PROBE TO CONTROL UNIT See Figure 2 on page 2. At the control unit, connect the RED probe wire to terminal No. 17; connect SHIELD (Drain) wire to terminal No. 18; and connect the BLACK wire to terminal No. 19. MULTI-PROBE ASSEMBLIES See Figure 4. The CF-2C system can support up to 100 standard CT-6 probes without loss of sensitivity when wired in series. The probes should be hooked up as shown in Figure 4. All interconnections must be soldered and taped. Solder-tin the leads before connecting to terminals Nos. 17, 18, and 19. PHASING PROBES Phasing of multi-probe assemblies is important when a probe is placed on both sides of the same driveway, or several probes are linked together to cover a large area. Phasing is not important in installations where a vehicle does not pass between two probes, such as probes used on separate driveways or when several probes are linked together at greater than 50 foot intervals. The phase output of the probe is controlled at the time of manufacturing. Please contact technical support at for more information. PROBE SYSTEM SUPERVISION When the probe wire is cut or the probe has been damaged by lightning (and thereby opencircuited ) or the BLACK wire is shorted to the SHIELD wire, the PROBE FAULT red LED light located on the circuit board will light and the sounder(s) will continuously cycle on and off, indicating the probe system has been violated. For example, if yard work was being done and the CF-2C went into PROBE FAULT mode, that would indicate when the wire was damaged. In high security areas, this feature is extremely valuable. If the RED and BLACK probe wires are shorted together, the PROBE FAULT SYSTEM will not go into alarm mode and the CF-2C control will not respond to the probe or the TRIP TEST button. If the circuit board has stopped working, use the instructions in USING PROBE FAULT MODE FOR TESTING (see below) to test the CF-2C circuit board. To test the probe for possible damage, refer to CT-6 Probe and Wire Check-out on page 3. SPECIAL NOTE: To disarm the sounder cycle and to test the circuit board when in the PROBE FAULT mode, remove the probe wires from terminal Nos. 17, 18, and 19; then short out terminals No. 17 and 19 by connecting a wire between them. The PROBE FAULT light should immediately go out and the cycling should stop in about a minute. If the LED does not go out, there is component failure on the circuit board. Another way to stop the cycling is to cut the stand up diode lead of D2. D2 is located center right on the board to the right of, and adjacent to, the TRIP TEST button. The board is marked in white letters D2 under the diode. USING PROBE FAULT MODE FOR TESTING With power applied and the probe wires disconnected, if the LED does not light, there may be power supply failure. If the LED does light but does not cycle the annunciator(s), the cause may be related to one of three things: 1. The exit delay timer has not timed out (see Adjusting CT-A1 Exit Delay on page 9.) 2. Wiring problems going to terminal No Component failure on the circuit board 6 Figure 4

9 Other uses in PROBE FAULT mode: The cycling of the sounders can be used to set CT-A1 exit delay time (see page 9 ), annunciator duration (see page 10), and re-trigger hold-off time (see page 10). It may also be used to check all of the sounders without the need for a vehicle tripping the system. SD-6 SHORT DRIVEWAY PROBE SYSTEM The SD-6 is a dual-probe set that works with the CF-2C and differs from the CT-6 in that it can be as close as 10 feet to outside cross traffic. Only one SD-6 system can be used with a CF-2C control unit. For installation instructions, please refer to the manual accompanying the SD-6 dual-probe system. CONNECTING OTHER SENSING DEVICES TO CONTROL UNIT See Figure 2 on page 2. The CF-2C is engineered to accept other sensing devices in conjunction with or exclusive of the CT-6 probe. You may use as many and as varied sensing devices as you like. To do so, you will need the following: 1. A sensing device with a normally open, floating, dry relay contact 2. A ohm resistor To connect your sensing device to the CF-2C, attach one side of the device to terminal 17, the other side to terminal 19 and place a ohm resistor across those two terminals. INSTALLING PHOTOCELL BLOCK See Figure 2 on page 2. The FC-6 photocell is designed to be mounted on a window pane with its "eye" looking outside. Its distance from the control unit is not important. To insure good adhesion, clean the window area with alcohol. Peel off the double-sided tape cover paper and mount the photocell on the window. The hole on the sticky side of the photocell should be at the top, and the screw terminals situated so that the wires will be connected from the top. Using a 2-wire, shielded cable, connect the two primary wires to the screw terminal on the photocell. The shield drain wire does not connect to anything on the photocell. Cut it off there. At the CF-2C control unit, connect the SHIELD drain wire to terminal No. 16, and the two primary wires to terminals No. 7 and 15 (see Figure 2 on page 2). Note: Static discharge from lightning can damage the photocell. It is therefore important to use shielded cable for photocell hook up. SPECIAL NOTE The FC-6 and FC-12 photocells are manufactured by Cartell and function as a light sensitive resistor. Measuring with an ohm meter, the resistance generally will be in the 2000 to 5000 ohm range in full sunlight. As the light diminishes, the resistance instantly goes up. The CF-2C floodlight timer circuit is locked out when the resistance is below 1 mg-ohm. When measuring the resistance between the two leads going to the photocell, if the resistance does not vary with a change in light level, the photocell may have been damaged by lightning; if it is shorted or open, there may be wire damage. A lightning damaged photocell or a shorted wire will keep the CF-2C lights from coming on at night. An open wire to the photocell will allow the lights to come on day and night. INSTALLING SOUNDERS (ANNUNCIATORS) MOUNTING Install sounders in a single-gang electric box for flush mounting. WIRE Use CAT-5 wire. To avoid corrosion, solder-tin the ends of the wires before connecting to the sounder and control unit. Always connect the wire to the sounder first and then to the control unit. 7

10 WIRE CHECK-OUT After connecting wires to the sounder, and before connecting to the control unit, systematically measure the resistance between each wire with every other wire. Resistance should never be less than 75 ohms. Resistance less than 75 ohms shows damage to the wire between control unit and sounder (e.g., a staple through the wire) and will damage the power supply if it is connected to the control unit. CT-A1 SOUNDER FEATURES AND INSTALLATION INSTRUCTIONS THREE TONES The CT-A1 allows three tones: steady, slow-pulse, fast-pulse. It is suggested the installer sample the tones for the customer to choose. To hear a sample of the steady tone, push the button marked PROG. To hear a sample of the slow-pulse tone, push the button marked DOWN. To hear a sample of the fast-pulse, push the button marked UP. Note: power must first be applied to the CT-A1 before it will sound. PROGRAMMING VOLUME To adjust volume, keep the button marked PROG pushed in the entire time you are increasing or decreasing volume (it will continue to sound as long as it is pushed in, demonstrating adjusted volume). With PROG pushed in, push the button marked UP to increase volume one increment. Keep PROG pushed in, wait one second, and push UP again. Repeat until desired volume is reached. With PROG pushed in, push the button marked DOWN to decrease volume one increment. Keep PROG pushed in, wait one second, and push DOWN again. Repeat until desired volume is reached. Note: when highest or lowest volume setting is reached, the LED will blink once. MUTING SOUNDER To mute sounder, keep PROG button pushed in and push the DOWN button two times in quick succession (in less than one second). The LED will begin blinking and continue blinking the duration of the mute cycle. To restore sound, hold PROG button down and push the DOWN button two times in quick succession as before. The LED will stop blinking when sound is restored to its previous setting. ADJUST TIMING (OPTIONAL) The default timing for the CT-A1 is set at the control unit (see Adjusting Sounder (Annunciator) Time on page 10). However, if a longer sounding time is desired for individual CT-A1 s, it can be lengthened by turning the pot on the sounder s circuit board counter-clockwise (CCW). ON, RESET and EXIT ADDITIONAL FEATURES AND CHIRP The CT-A1 has additional features made available by three function-buttons on the plate: The ON button instantly trips the floodlight timer and the floodlights are switched on for the time period set by the control unit or until the RESET button is pushed. RESET instantly cancels the floodlight timer and turns off the lights operated by the CF-2C. EXIT button activates the preset exit delay timer, de-activating the sensor probe. This allows a vehicle to drive by the probe without tripping the system, Normal standby mode occurs after the exit delay timer times out (see Adjusting CT-A1 Exit Delay, on page 9). These buttons lack a tactical feel, but when pushed, a small audible CHIRP should be heard. SPECIAL NOTE: Many installers use the CT-A1 as a means of safety for the woman home alone at night. By installing the CT-A1 just outside or inside the master bedroom, one need only push the On button from the convenience of the bedroom when suspicions are raised by outside noises. Doing so will turn on all lights operated by the CF-2C and inform outsiders, if they exist, that they have been detected. 8

11 INSTALLING CT-A1 SOUNDER (replacement sounder for FC-9, CT-8 and CT-8A) See Figure 5. Connect wires to CT-A1 first, test resistance, then connect to the CF-2C. At CT-A1, connect a wire to terminal V. At CF-2C, test resistance and connect this wire to terminal 6. At CT-A1, connect a wire to Figure 5 terminal G. At CF-2C, test resistance and connect this wire to terminal 15. At CT-A1, connect a wire to terminal S (for steady tone) or P1 (for fast pulsating tone) or P2 (for slow pulsating tone). At CF-2C, test resistance and connect this wire to terminal 14. At CT-A1, connect a wire to terminal E. At CF-2C, test resistance and connect to terminal 9. At CT-A1, connect a wire to terminal R. At CF-2C, test resistance and connect to terminal 10. At CT-A1, connect a wire to terminal M. At CF-2C, test resistance and connect to terminal 8. INSTALLING CT-11 SOUNDER See Figure 2 on page 2. Please read the instructions in the introduction. First make the connections at the CT-11 plate and then to the control unit as follows: Connect one colored wire to the terminal marked. At the control unit, test the resistance as noted above. Then proceed to connect this wire to terminal 15. Connect another colored wire to the terminal marked +. At the control unit, test the resistance as noted above. Then proceed to connect this wire to terminal 14. INSTALLING AA-1 & CT-11 SOUNDERS See Figure 2 on page 2. Connect the RED lead to the terminal marked SON (or +) on the sounder. Connect the BLACK lead to GND (or ) on the sounder. At the control unit, test the resistance RED to BLACK as noted above. If resistance proves correct, at the control unit connect the RED lead to terminal No. 14. Twist the BLACK lead to the SHIELD wire and connect to terminal No. 15. ADJUSTING CT-A1 EXIT DELAY See Figure 6. The exit-delay time (potentiometer C ) can be adjusted from 50 seconds to 15 minutes. To determine the exit delay time, first remove the RED probe wire from terminal No. 17. This will put the CF-2C into PROBE FAULT mode (see page 6). When the exit delay timer times out the annunciator relay will constantly cycle on and off. To activate the exit delay timer on an installed CT-A1 annunciator, press the exit delay button on the annunciator plate. If other devices are being used to activate the exit delay timer (such as an alarm panel, etc.), take a wire and short the terminals between No. 9 and No. 15 at the CF-2C control panel. Doing this for 2 seconds will trigger the timer. When the timer is activated, the annunciator relay will stop cycling. Measure the time from when the relay stops and when the relay begins cycling again and you will know the exit delay time. For longer exit delay time, adjust the potentiometer marked C clockwise and repeat until the desired time is achieved. Re-attach the RED probe wire to terminal No. 17 when finished. 9

12 ADJUSTING SOUNDER (ANNUNCIATOR) TIME See Figure 6. This function controls the amount of time the customer desires the noisemaker to stay on. It may be adjusted to stay on anywhere from 1/2 to 30 seconds. To adjust, use the potentiometer marked "F". Turning it clockwise increases the time. Push the trip-test switch to hear your adjustment. Adjust until the desired time is achieved. NOTE: Each CT-A1 may be adjusted individually from its own circuit board (see Adjust Timing instructions under CT-A1 operational features, page 8). ADJUSTING RE-TRIGGER HOLD-OFF See Figure 6. The re-trigger hold-off keeps the system from re-triggering (and thus annunciating) should multiple cars pass the probe in a caravan. Once the system is tripped, it will time-out but not be able to re-trigger for an adjustable time period up to 2½ minutes. To adjust this time period, disconnect the RED probe wire from terminal No. 17 (this puts the control unit in PROBE FAULT mode, see page 6). The annunciator relay will constantly cycle on and off. To increase the re-trigger hold-off, adjust potentiometer marked "E". Turn it clockwise for a longer hold-off period of time. Repeat until the desired hold-off time is achieved. Re-attach the RED probe wire. ADJUSTING FLOODLIGHT ENTRY DELAY TIME Figure 6 See Figure 6. This function can be used to delay activation of the floodlight timer after the CF-2C is tripped. Adjustment time is from 1 second up to 2½ minutes. For long driveways, or if the exact location of the probe is to be concealed for security reasons, use this feature. The annunciator, however, is not delayed. To set the desired floodlight entry delay timer, first remove the photocell lead from terminal No. 7 (see Figure 2 on page 2) on the CF-2C control unit. Push the TRIP TEST button and measure from the moment the annunciator relay clicks on (a relatively quick click) and the moment the floodlight relay activates (a relatively loud click). To increase the delay time, adjust the potentiometer marked A clockwise. After the floodlight relay times out, repeat the cycle until the desired time is achieved. Re-connect the photocell wire to terminal No. 7. SPECIAL NOTE: Do not use the ON button on the CT-A1 annunciator plate to set the entry delay time. On the CF-2C, the ON button on the CT-A1 instantly activates the floodlight timer, bypassing the entry delay timer circuit. 10

13 ADJUSTING FLOODLIGHT TIME See Figure 6 on page 10. The amount of time the floodlights remain on after the system is tripped may be adjusted from 15 seconds to 15 minutes. The normal floodlight time is 5-10 minutes. To set the floodlight time, remove the photocell wire from terminal No. 7. Push the TRIP-TEST button. Measure from the moment the floodlight relay clicks on to the moment it clicks off. Adjust potentiometer "B" (clockwise for time increase) and repeat until desired time is achieved. Reconnect the photocell wire to terminal No. 7. ADJUSTING PHOTOCELL SENSITIVITY See Figure 6 on page 10. Photocell sensitivity determines the level of outdoor light at which the lights are allowed to come on. The factory sets the floodlights to come on at dusk. To set the photocell sensitivity, make all adjustments at the precise moment when the amount of daylight is visible at which time you want the floodlights to come on. Adjust potentiometer "D" counter clockwise in very small increments and push the TRIP-TEST button after each adjustment (see page 3). Stop adjusting at the point where the floodlight relay clicks on. The floodlights will be allowed to turn on at that same daylight level from then on. ADJUSTING PROBE SENSITIVITY See Figure 6 on page 10. Probe sensitivity is set at the factory and does not usually need to be adjusted. Factory setting allows a single standard probe to cover a 12 foot wide driveway when installed beside it (see "Installing CT-6 Probe and Cable" on page 5). Increasing the sensitivity above the factory setting is not recommended unless the probe is located in a low sensitivity area. When the probe is placed in the center of a driveway that is 18 feet wide or less, the sensitivity may be decreased considerably, allowing the probe to be installed close to highway traffic or power lines. To adjust probe sensitivity, turn the potentiometer "G" clockwise to increase, counter-clockwise to decrease. A typical setting should be such that the CF-2C reliably detects a small car going 5 MPH. You may increase sensitivity if necessary. Be aware, increasing sensitivity may cause false alarms. ADJUSTING TRANSIENT SUPPRESSOR See Figure 6 on page 10. The factory setting for the transient suppressor circuit potentiometer "H" is in the "on" position (fully clockwise). In this setting, short duration transient signals will be ignored. With the circuit activated, false alarms from lightning will be reduced. Note: if the probe sensitivity cannot be properly set as described in the "Adjusting Probe Sensitivity" section (above), turn off the transient suppressor by adjusting potentiometer "H" fully counter-clockwise. FIELD TROUBLESHOOTING Cartell does not provide schematic diagrams or service manuals for our products. However, we try our best to provide technical support through our number and fast repair service for our products. Before calling Cartell, refer to the SPECIAL NOTE sections under the following headings: Initial power-up and exit delay, page 2 Purchasing ground rod, page 3 Sensor probe check of existing installations, page 4 Probe system supervision, page 6 Using Probe Fault Mode to test circuit board, page 6 11

14 Testing photocell, page 7 Location of CT-A1, page 8 Entry delay time, page 10 When trouble-shooting a CF-2C system that is false alarming, check the ground system. House electrical panel grounds can cause transient feedback that could cause false alarms. To determine if false alarms are board related or probe system related, disconnect the probe and connect a 500 to 1000 ohm resistor across terminals 17 and 19 and leave it connected for a long period of time. If the board false alarms, it is circuit board related or ground system related. If it does not false alarm with the resistor installed, then the probe system is suspect. NOTE: when troubleshooting the CF-2C, an active cell phone within five feet of the control unit will cause the system to false alarm. If either the probe or control unit fails the test, call Cartell's technical staff using the number. Further instructions will be given or authorization to return the ostensibly defective product for testing and repair. If the probe is bad, there is no way of repairing it. It is recommended that all repairs be returned directly to Cartell and not be sent through a distributor. SPLICING PROBE CABLE The cable supplied with your system is coated with polyurethane because it will bond with epoxy and make a sealed splice. If you purchase your own cable, make sure it is polyurethane coated or it will not splice. Improper cable splices will cause false alarms. To insure a proper splice, follow the instructions below. Two items are necessary when splicing, both available from Cartell: First, a two-wire shielded direct burial cable (unshielded cable and PVC jacketed cable will not give proper splices). Second, an underground splice kit (made by 3M, part #82-F1; Cartell's part number is CA-1). The following instructions assume you have these products. 1. See Figure A. Strip the outer jacket on one cable back 10 inches and cut the RED and BLACK leads to 3 inches. Leave the SHIELD drain wire the full 10 inch length. Strip the outer jacket off the mating cable back 3 inches and strip the jacket of the RED and BLACK lead of both cables back ½ inch. Twist the BLACK to BLACK and RED to RED and solder the connections. 2. See Figure B. Trim the RED and BLACK joints and tape for proper insulation. Twist the 3 inch SHIELD drain wire to the 10 inch SHIELD drain wire and solder the connection. DO NOT cut off the excess SHIELD drain wire. 3. See Figure C. Wrap aluminum foil around the splice area (to properly shield it). Wrap the 10 inch SHIELD drain wire tightly around the outside of the foil and solder it to itself in order to hold it in place. This procedure insures that any signal to the splice SHIELD will drain to ground and thus prevent false alarms. 4. See Figure D. Place an underground splice kit potting container around the spliced cable and epoxy, following the kit instructions carefully. 12

15 LIMITED FIVE YEAR WARRANTY All Cartell products are warranted against defects in material and workmanship for five years. This warranty does not cover defects caused by, but not limited to: acts of God, improper installation, abuse, fire and water damage, electrical surges, and damage to cable caused by slicing, pulling, tangling, or improper splicing. MERCHANDISE RETURN INFORMATION If you re the end-user, please consult the dealer/installer who installed your Cartell system before attempting to return it. Dealer/Installer, please call Cartell at to troubleshoot the system over the phone and to receive a Return Merchandise Authorization (R.M.A.) number. TECHNICAL SPECIFICATIONS - CF-2C CONTROL UNIT POWER REQUIRED: STANDBY CURRENT: ALARM CURRENT: RELAY CONTACT RATING: RELAY TIME: FLOODLIGHT CONTACT FLOODLIGHT TIME FLOODLIGHT DELAY BATTERY CHARGER 12 VAC or VDC 35 ma 180 ma max. with (1) FC-9 or (1) CT-8 Double Pole, Double Throw 1st Pole: 12 VDC, 200 ma for remotes 2nd Pole: SPDT, 5 amps, 30 VDC 1/2 to 30 seconds SPST, 15 amp, 125 VAC CSA certified (1800 watts) 15 seconds to 15 minutes 1 second to 2 1/2 minutes 13.5 VDC, 5 ma minimum charge (w/ voltage off) TEMPERATURE RANGE: 35 o F. to 140 o F. DIMENSIONS: WEIGHT: 7 1/2 in. x 12 3/4 in. x 3 in. 5 lbs. TECHNICAL SPECIFICATIONS - CT-6 PROBE TEMPERATURE RANGE: PROBE DIMENSIONS: WEIGHT: OTHER: -40 F F 16 1/2 in. x 1 3/8 in. diameter 3.5 lbs. with 100 cable 500 to 800 ohms coil resistance depending on length of cable 13

16 510 West King Street, Shippensburg, PA Manufactured by

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128

CarSense202 O P E R A T I N G I N S T R U C T I O N S V E HI C L E M O T I O N D E T E C T O R Johnston Parkway, Cleveland, Ohio 44128 O P E R A T I N G I N S T R U C T I O N S CarSense202 V E HI C L E M O T I O N D E T E C T O R 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com

More information

Operating Instructions

Operating Instructions CS202S CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS202 as a safety reversing or presence detection system. The CS202 requires that a vehicle be moving

More information

Pulse Input Adapters (Part # S-UCC/D-M006) for use with HOBO H21 and H22 Series Data Loggers

Pulse Input Adapters (Part # S-UCC/D-M006) for use with HOBO H21 and H22 Series Data Loggers s (Part # S-UCC/D-M006) for use with HOBO H21 and H22 Series Data Loggers The s are used to log the number of switch closures per interval and are designed to work with smart sensor-compatible HOBO data

More information

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07) DP2 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Door Phone Range Page 5 Door Phone Performance Page 6 Operation Summary

More information

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14) (Part # S-VIA-CM14) The 12-Bit 0-5 Volt Input Adapter is used for measuring voltage levels and is designed to work with the HOBO Weather Station and Micro Station data loggers. The input adapter also provides

More information

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions WCAIM2029 (Part 16022) Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions CAUTION: Flowserve recommends that all products that must be stored prior to installation be stored

More information

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time DP2 Door Phone For Technical Assistance call the Manufacturers direct ph 0800 530 8645 9AM - 5PM West Coast Pacific Time NATCOMM USA LLC Supplier Code : NC TABLE OF CONTENTS Description Page 3 Door Phone

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA MC-1 MINI CAMERA OPERATION MANUAL JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA 02718 USA (508) 822-7330; (800) 822-4744; FAX (508) 880-8949 Email: info@jwfishers.com WEB: www.jwfishers.com SPECIFICATIONS

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-300

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-300 INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-300 COPYRIGHT 1988 American Mine Research, Inc Manual Part Number 160-0094 Original: 07-19-88 Revised: 03-28-90 NOT TO BE CHANGED WITHOUT MSHA

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

MODEL K INSTRUCTION MANUAL CONTENTS

MODEL K INSTRUCTION MANUAL CONTENTS MODEL 7173 - K INSTRUCTION MANUAL CONTENTS 1. MODEL 7173 - K ELECTRONIC FFU STEERING SYSTEM 2. MODEL 7173 - K COMPONENTS 3. MOUNTING THE 7173 - K AMPLIFIER UNIT 4. MOUNTING THE FFU CONTROLLER UNITS 5.

More information

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE WPP(HOB)-331-D or SSP-311-D ATD-11 Issue 5.00 SERVICE MANUAL FOR MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE EQUIPPED

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

MT400 MOTION CONTROLLER

MT400 MOTION CONTROLLER MT400 MOTION CONTROLLER INSTALLATION & TECHNICAL MANUAL 5/30/2012 417 Wards Corner Road Loveland, OH 45140 800.659.8250 FAX: 513.398.2536 www.maxitronic.com Table of Contents Page 3: Page 4: Page 5: Page

More information

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.111 Rev.4.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND CONNECTION BOARD 3

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MicroComm DXI. Intent & Scope This document describes the installation procedure for the IMS-30 Intercom Master Station and the MAI-420 or MAI-20 Master Audio Interface. The earliest

More information

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07) DP4 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Description Continued Page 5 Door Phone Range Page 6 Door Phone Performance

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

700 Series 200 Amp Clamp Meters

700 Series 200 Amp Clamp Meters 700 Series 200 Amp Clamp Meters #61-700 #61-701 #61-702 1 2 3 6 5 7 4 8 1. Non-contact voltage (NCV) (#61-701 and #61-702) With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV

More information

Installation Instructions

Installation Instructions Please read all instructions before installing RS-350 PIR Dual Relay Universal Application Wall Switch Vacancy Sensor with Manual ON/OFF Lens Lighted Switch ON/OFF button for Relay 1 ON/OFF button for

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA WPP-531-X-ADA OR SSP-511-X-ADA-SPK1.07-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA HANDS FREE EMERGENCY WEATHERPROOF TELEPHONE OR MODEL SSP-511- X-ADA HANDS FREE STAINLESS STEEL PANEL TELEPHONE EQUIPPED

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

EMS Electrical Management System

EMS Electrical Management System EMS Electrical Management System Complete Installation/Operating & Warranty Guide EMS-HW50C Rated at 240 Volts/50 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises

More information

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches SSP-3-F -ISSUE 4.0 Service Manual For -IP Voice over Internet Protocol -ACH** Handset cord length Inches -M Magnetic Hookswitch -CCH Coiled cord length Feet 5, 0, or 5 -BK Braille Keypad -PBVC Pushbutton

More information

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR

More information

Computer Temperature Interface model CTI-2. Description. Installation. Control Module

Computer Temperature Interface model CTI-2. Description. Installation. Control Module Description The Sine Systems model CTI-2 Computer-Temperature Interface allows a computer to monitor the outside air temperature. It consists of a 2.75 x 3 x 0.75 control module with 8 screw-terminal connections.

More information

Drive 3G-S ENGLISH. Cellular Signal Booster A Customer Support: Mon-Fri 8 am to 6 pm.

Drive 3G-S ENGLISH. Cellular Signal Booster A Customer Support: Mon-Fri 8 am to 6 pm. ENGLISH Drive 3G-S Cellular Signal Booster A512626 ENGLISH!! IT IS VERY IMPORTANT TO POWER YOUR SIGNAL BOOSTER USING A SURGE PROTECTED AC POWER STRIP WITH AT LEAST A 1000 JOULE RATING. FAILURE TO DO THIS

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Display: EZ100 11/12/04-1 - Congratulations on your purchase of the EZ100 Display.

More information

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE MHW-341-Fr1-XFD-ISSUE5.0 SERVICE MANUAL FOR MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE EQUIPPED WITH VOLUME CONTROL, BACKGROUND NOISE ELIMINATION, XFD PRINTED CIRCUIT, AND RECEIVER- OPERATED

More information

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT VSP- Issue 4 ONE ZONE HANDSFREE TALKBACK CONTROL UNIT INTRODUCTION The is a One Zone Handsfree Page Unit for use on an Electronic Key system line key position, a PABX loop start trunk port, a dedicated

More information

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code: INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA-675-001 Revision 1.0 Date Code: 1-1-2018 Table of Contents Table of Figures... 3 SPECIFICATIONS:... 4 INSTALLATION... 5 General:... 5 Physical Installation

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec THETA LABS INC Aguila AZ 85320-0734 928-671-1885 www.thetalabs.com CONTENTS 1. DESCRIPTION & SPECIFICATIONS page 1.1 General 1 1.2 Mechanical

More information

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1. WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone

More information

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE WPP(HOB)-531-D2 OR SSP-511-D2-SPK1.07UNVL-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE OR MODEL SSP-511-D2 STAINLESS STEEL PANEL

More information

LPG STM 94442A User s Manual

LPG STM 94442A User s Manual 1 LPG STM 94442A User s Manual This Manual belongs to: Company: 3 Table of Contents Features....... 4 Hardware Installation...5 Monitor Mounting Dimensions.....7 Monitor Specifications...8 Sender Specifications.....9

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

Rotork Fairchild PAX1 Linear Actuator User s Manual

Rotork Fairchild PAX1 Linear Actuator User s Manual Rotork Fairchild PAX1 Linear Actuator User s Manual Product Overview The PAX1 is a flexible low voltage DC powered linear actuator featuring a 5 mm maximum thrust rod stroke moving at speeds up to 0 mm/min

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Series SD-3PB Digital THERMOSTAT + TIMER

Series SD-3PB Digital THERMOSTAT + TIMER SD-3PB Thermostat and Interval Timer in one Unit. This microcomputer based controller consists of two sections: The Digital Timer and Digital Thermostat, working together to control the power switched

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0 Installation & User Guide Model 8ZEXT V1.0 2010 DuWa Products LLC PN1370-04 Table of Contents Introduction... 1 Overview... 2 Installation Instructions... 3 Installation Options... 3 Installing the Encoder...

More information

smartentry Wireless Video Doorphone User Manual

smartentry Wireless Video Doorphone User Manual smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4

More information

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English) Total Home Surge Protection for Point-of-Entry FirstSurge TM User Manual - Canada (English) www.siemens.ca/surge Introduction Thank you for choosing the Siemens FirstSurge Residential Surge Protective

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

Pulse LED Instruction Guide

Pulse LED Instruction Guide PARTS LIST Light Fixture Aquarium Frame Mounts Instruction Guide WARNING: To guard against injury, basic precautions should be observed, including the following: A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

Global Water globalw.com. Global Water. Instrumentation, Inc.

Global Water globalw.com. Global Water. Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com PC300: Process Controller

More information

703 F o u r B u t t o n D E C T I n t e r c o m

703 F o u r B u t t o n D E C T I n t e r c o m Installation & User Manual For 703 F o u r B u t t o n D E C T I n t e r c o m Wireless Intercom System Models AB, ABK, HB, HBK, Version 1.1 (2 Relay Version) P a g e 1 Contents Overview of system.pg 3

More information

SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE

SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE Microframe Corporation 604 South 12th Street Local: 918-258-4839 Toll Free: Website: www.microframecorp.com E-mail: support@microframecorp.com Revision

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM SIG:EMS 1 of 6 APPR:LWB:DBP:07-17-14 FHWA:APPR:07-30-14 a. Description. This work consists of either furnishing

More information

Installation Instructions

Installation Instructions Please read all instructions before installing SPECIFICATIONS RT-100 Time Switch Programmable Countdown Voltage...120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fluorescent lamp... 0 600 Watt

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

poly-planar Marine Audio System

poly-planar Marine Audio System ME-52 Expansion Amplifier 1 ME-52 Expansion Amplifier Introduction: The ME-52 is a 2 channel audio amplifier capable of delivering up to 25W RMS per channel. It s compact, water resistant design allows

More information

232iLM Keypad Installation and Programming Instructions

232iLM Keypad Installation and Programming Instructions 232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F) SSC-301-F OR BLC-301-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-301-F (FORMERLY 301-FS) OR MODEL BLC-301-F (FORMERLY 301-F) CHARGE-A-CALL TELEPHONE Serving the Telephone Industry Since 1930 Communication

More information

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7 User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7

More information

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE WPP-531-D OR SSP-511-D-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE WITH OPTIONAL ADA

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could

More information

V-9939C MICROPHONE ADAPTER

V-9939C MICROPHONE ADAPTER Issue 2 INTRODUCTION These instructions provide identification, installation, connection, operation and maintenance information for the Microphone Adapter. The is a Microphone Adapter designed to be used

More information

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

GARDEN SPEAKERS GS4 INSTALLATION GUIDE RevA-GS4-SpkManual.indd 1

GARDEN SPEAKERS GS4 INSTALLATION GUIDE RevA-GS4-SpkManual.indd 1 GARDEN SPEAKERS GS4 INSTALLATION GUIDE 9901210-RevA-GS4-SpkManual.indd 1 parts List ground stake mounting 2 GS4 Satellite Loudspeakers with attached wall-mount brackets 2 Mounting Stakes (Optional) 2 Pairs

More information

EMS-LCHW30 & EMS-LCHW50

EMS-LCHW30 & EMS-LCHW50 Electrical Management System (EMS) EMS-LCHW30 & EMS-LCHW50 Installation & Operating Guide for: Model EMS-LCHW30 Rated at 120V/30A and Model EMS-LCHW50 Rated at 240V/50A Surgio Says Lifetime Warranty on

More information

IRRIGANDER 4 SPLITTER SWITCH

IRRIGANDER 4 SPLITTER SWITCH IRRIGANDER 4 SPLITTER SWITCH 4 Zone Irrigation Valve Switch Installation & User Guide Model 4ZES V1.0 2016 DuWa Products LLC PN1940-02 Table of Contents Introduction... 1 Overview... 2 Installation Instructions...

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

605 D E C T G I n t e r c o m

605 D E C T G I n t e r c o m Installation & User Manual For 605 D E C T + 2. 4 G I n t e r c o m Wireless Video Intercom System Models 605AB, 605ABK P a g e 1 Contents Overview of system.pg 3 Site Survey.Pg 3 Mounting the Transmitter.Pg

More information

Energy Management System. Operation and Installation Manual

Energy Management System. Operation and Installation Manual Energy Management System Operation and Installation Manual AA Portable Power Corp 825 S 19 TH Street, Richmond, CA 94804 www.batteryspace.com Table of Contents 1 Introduction 3 2. Packing List 5 3. Specifications

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor 24/7 Sprinkler Monitor The Ultimate Rain/Freeze Sensor User s Manual PIONEER SALES, LTD. 5529 Redfield St. Dallas, TX 75235 Phone: (214) 276-0306 Fax: (214) 631-4218 Toll Free: 1-(866) 501-7745 1 Table

More information

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD SSC-500-F-(501-FSZ)-ISSUE4.0 SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD Serving the Telephone Industry

More information

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE WPP(HOB)-531-D OR SSP-511-D-SPK1.07UNVLADA-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE OR MODEL SSP-511-D STAINLESS STEEL PANEL TELEPHONE

More information

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS FEATURES ADA Compliant (hands free operation) LED call status indicator Powder coated steel construction inside

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MicroComm DXI MAI-425 Master Audio Interface. Intent & Scope This document describes the installation procedure for the MAI-425 Master Audio Interface. The earliest version of

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override Varifan 3 4 5 6 7 MANUAL 2 8 1 OFF 10 9 AUTO MANUAL SPEED Installation / User s Guide This guide will inform the electrician on proper wiring

More information

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... P.2 2. STANDARD AND OPTIONAL PARTS LIST..... P.2 3. FEATURE DEFINITIONS... P.3 4. TERMINAL DRAWING AND SPECIAL

More information

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual Emergency Solar Tower Phone 2100-TSL Landline Solar Tower 2100-TSC Cellular Solar Tower 2100-TS9 900 MHz Solar Tower 2100-TST 2-Way Radio Solar Tower 2100-TSV VoIP Solar

More information

5000 Series Audio Matrix

5000 Series Audio Matrix 5000 Series Audio Matrix FOR TECHNICAL SUPPORT CALL 513-795-5332 For more complete system information see the document 5000 Series Audio/Video System Installation & Service Manual 08-316 (11/12/13) Matrix

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

1-36V, 0-3A DC Power Supply

1-36V, 0-3A DC Power Supply 1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,

More information

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver. Connection Technology Center, Inc. Vibration Analysis Hardware DD1590 Series Proximity Probe Driver Product Manual C:\Documents and Settings\mclarneys.ctc\Desktop\MNX10016 DD1590 PROXIMITY PROBE Manual.doc

More information

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional

More information

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error: 41-766.7 SSV-T and SSC-T High Drop-out Relay device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the

More information

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System User s Manual D-M-E Company D-M-E Company MFA-0801 & MFA-1201 Page 1 Copyright D-M-E Company 1995. All rights reserved. D-M-E

More information

What s in the Box? REAR VIEW SAFETY

What s in the Box? REAR VIEW SAFETY TM 1 What s in the Box? 1 Full HD Color Infra-red Weather Proof Camera 1 Full HD 7" TFT LCD Color Monitor w/monitor Mount 1 Power Harness 1 66 Camera Cable 1 Power Connection Wire 1 Screw Kit for installation

More information