1 Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and RS-/8 devices. All signal lines have,00-vac insulation at the RS-C/USB and RS-/8 sides using optocouples, and power supply lines have,00-vac insulation using a transformer. Compact 0-mm-wide body supports both screwmounting and DIN track mounting. LED indicator for RD, SD, and power. CRUS Operation either with or without echoback available. Conforms to EMC standards, EN00- (IEC00-). UL/CSA approved. Ordering Information Appearance Size (mm) Power supply voltage Model (W H D) 00 to 0 VAC to 0 VAC VAC/VDC -0 VAC/VDC Accessories (Order Separately) Name Adapter for RSC Serial Cable and K-09 Model Specifications Ratings Item to 0 VAC -0 VAC/VDC Power supply voltage 00 to 0 VAC 0/0 Hz VAC 0/0 Hz, VDC Allowable power supply fluctuation range 8% to 0% of power supply voltage Power consumption VA max. VA max./ W max. Communications format of master device (e.g., computer) RS-C, USB (selectable) Communications format of slave device (e.g., RS-: -wire full-duplex mode, RS-8: -wire half-duplex mode (selectable) component) Communications method Start-stop synchronization Ambient operating RS-C 0 to C (with no icing) temperature USB 0 to C (with no icing) Ambient operating humidity % to 8% (with no condensation) Ambient storage temperature 0 to C

2 Characteristics Master device RS-C interface USB interface (See note.) Item Maximum transmission distance Maximum number of connectable Units Maximum transmission distance m Unit Maximum number of Unit connectable Units USB standard V. m; hub delay time + cable delay time ˆ 0 ns Specification Slave device RS-/8 interface Maximum transmission distance Maximum number of connectable Units 00 m Units (for multi-drop connection) Baud rate Data length Stop bit length Communications parity Echoback selection Selection switch response delay Insulation resistance Dielectric strength Isolation method Communications Power supply,00/,00/,800/9,00/9,00/8,00 () Default setting: 9,00 /8 bits Default setting: / bits Default setting: None/even/odd Default setting: Even Echoback: With/without Default setting: Without Approx. 0 ms 0 MW min. measured at 00 VDC between the following: External terminals casing RS-C terminals and USB port RS-/8 terminals power supply terminals Phototransistor coupler Isolating transformer,00 VAC for minute measured between the following: External terminals casing RS-C terminals and USB port RS-/8 terminals power supply terminals Noise immunity AC power supply terminals, normal/common mode:,00 V AC/DC power supply terminals, normal mode: 80 V; common mode:,00 V Square wave with -ns rising edge ms, 00 ns Vibration resistance Malfunction 0 to Hz, 0.-mm single amplitude for 0 minutes each in X, Y, and Z directions Destruction 0 to Hz, 0.-mm single amplitude for hours each in X, Y, and Z directions Shock resistance Malfunction 98 m/s times each in X, Y, and Z directions Destruction 9 m/s times each in X, Y, and Z directions Weight Approx. 0 g Enclosure rating (See note.) Front panel operation parts Terminals Conforms to IEC standards, equivalent to IP0 (when terminal cover mounted) Equivalent to VDE 00/00 (when terminal cover mounted) EMC Radiated Emission: EN class A Conducted Emission: EN class A Approved standards Memory protection Immunity ESD: EN000--: -kv contact discharge (level ) 8-kV air discharge (level ) Immunity-RF-interference: EN000--: 0 V/m (amplitude modulated, 80 MHz to GHz) (level ) 0 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance: EN000--: 0 V (0. to 80 MHz) (level ) Immunity Burst: EN000--: -kv power-line (level ) -kv I/O signal-line (level ) UL08, CSA. No. -9; conforms to EN008-, EN008-, EN00- (IEC00-); conforms to VDE00/part 00 (Finger Protection) when the terminal cover is mounted. No protective functions (Communications data is not protected for power interruptions during communications.). A USB driver and communications software for the USB driver are required to use USB. This functionality is available with Windows 98/000 only.. The enclosure ratings do not apply when USB is used.

3 Nomenclature Terminal Cover without Terminal Cover Caution: Cover the terminals to prevent electric shock. Be sure to use the -0 with the terminal cover mounted when using in machinery that must conform to EN/IEC standards. Power Indicator Lights (green) when power is supplied. Communications Setting Switch Used to set the communications conditions for connected devices. Communications Setting Switch Switch Setting Baud rate Data length Parity 8 Master device 9 Slave device 0 Echoback Communications Status Indicators Light (yellow) during communications. RD: Lights when receiving RS-/8 communications. SD: Lights when sending RS-/8 communications. USB Port Port for USB connections. Use this port if the master device is a USB device. M. Terminal Screw Operation Communications Settings Switch Use this switch to set the communications conditions for the to those used by connected devices. Setting 8 9 0,00,00,800 Baud rate Data length Stop bits Parity Master device Slave device Echoback 9,00 9,00 8,00 8 Even Odd None RS- C USB RS- 8 RS- (without) (with) All pins are factory-set to.

4 Terminal Specifications Be sure to check the input and output specifications for the signal pins of connected devices before connecting the terminals. Function For connecting the operating power supply Connection terminals for RS-C communications with master device (DIP switch pin 8: ) Used for RS-8 communications with slave device (DIP switch pin 9: ) Used for RS- communications with slave device (DIP switch pin 9: ) Terminal number Name Signal direction Explanation and PWR --- The input power supply specifications vary with the model. A 00 to 0-VAC model and a -VAC/VDC (no-polarity) model are available. --- Connect to signal ground. SD Input Receives data from SD of the master device. RD Output Sends data to RD of the master device. 8 RDA(-) Input/output SD and RD for RS-8 (cold side) 9 Terminals 8 and 9 are connected internally when pin 9 of SDA(-) the DIP switch is set to. RDB(+) Input/output SD and RD for RS-8 (hot side) SDB(+) Terminals and are connected internally when pin 9 of the DIP switch is set to. --- Connect to signal ground. 8 RDA(-) Input Receives RS- data and outputs it to the master side. 9 SDA(-) Output Converts data received via RS-C from the master device to RS- data and outputs the data. RDB(+) Input Receives RS- data and outputs it to the master side. SDB(+) Output Converts data received via RS-C from the master device to RS- data and outputs the data. Terminals and 0 are not used. Internal Configuration (Block Diagram) DIP switch Status indicator Power indicator Switch input Indicator control Power supply RS-C RS-C driver Serial communications Serial communications PHC PHC RS-8 driver RS- or RS-8 CPU RS-8 enabling control PHC USB USB controller USB control Insulation

5 HB Installation External Connections RS-8 Connection Input power supply (See note.) SD RD (See note.) (See note.) Slave device side RS-8. If RS-8 is selected as the communications method (i.e., pin 9 of the DIP switch is set to ), terminals 8 and 9, and terminals and are connected internally.. Either a 00 to 0-VAC or -VAC/VDC (no polarity) input power supply is used. Connection to an RS-C Master Device (-) (+) Master device side RS-C Pin number (for 9-pin computer connector) 8 RS- Connection Input power supply (See note.) 8 9 RDA ( ) SDA ( ) 0 RDB (+) SDB (+) SD RD Abbreviation SDA ( ) SDB (+) RDA ( ) RDB (+) Either a 00 to 0-VAC or -VAC/VDC (no polarity) input power supply is used. First set the same communications conditions (baud rate, stop bits, data length, and parity) for the master device, the Interface Converter, and slave devices. Slave device side RS- Master device side RS-C Abbreviation SD RD RS CS DR ER Abbreviation SD RD RS CS DR ER Pin number (for 9-pin computer connector) 8 If the communications interface format for the master device is RS-C, set pin 8 of the DIP switch to. Devices connected via RS-8 (example) AL AL HB OT OT STP CMW Computer Wire with stranded wires. To allow connection using a commercially-available cable with an RS-C D-sub connector, a connection adapter (D-sub, 9-pin) is available. (Order separately; model number: K-09.) In addition to the required communications conditions, set the communications number. With RS-8 communications, connect a terminating resistance (0 W, / W recommended) to both ends of the communications path. Connection to a USB Master Device First set the same communications conditions (baud rate, stop bits, data length, and parity) for the Interface Converter and slave devices. A USB driver and host software for the driver are required. If the communications interface format for the master device is USB, set pin 8 of the DIP switch to. Devices connected via RS-8 (example) AL AL OT OT STP CMW Computer Remove the terminal cover when using USB. USB connection Use a commercially-available USB cable. In addition to the required communications conditions, set the communications number. With RS-8 communications, connect a terminating resistance (0 W, / W recommended) to both ends of the communications path.

6 Applications Monitoring and Maintenance of Installations and Equipment Computer Temperature Controller Interface Converter Digital Panel Meter Inspections and Debugging for Communications Equipment Computer Interface Converter

7 Installation Temperature Control with a Computer Device interior RS-8 RS- m max. Mounting devices, reflow devices, etc. Interface Converter EZN Temperature Controller Dimensions -0 Mounting Hole Dimensions (For Direct Mounting) Two, M or.-dia. holes 80 ± DIN track mounting is also possible.

8 Precautions!Caution Do not touch any of the terminals while power is being supplied. Doing so may result in electric shock.!caution Do not allow bits of metal or wire cuttings to enter the interior of the product as this may result in malfunction, fire, or electric shock.!caution Do not attempt to disassemble, repair, or modify the product. Any attempt to do so may result in malfunction, fire, or electric shock.!caution Tighten the terminal screws to the specified torque. Loose screws may result in burning or malfunction. The recommended tightening torque is 0.8 N m. General Precautions Do not mount the product in the following places: Locations subject to shock or vibration Outdoor locations or locations subject to direct sunlight, wind, or rain. Locations subject to temperatures or humidity outside the specified ranges Locations subject to condensation or icing Locations subject to large amounts of dust Locations subject to flammable gases or objects Locations subject to corrosive gases (in particular sulfide or ammonia gases) Be sure to check power supply specifications, terminal numbers, and polarities before performing wiring. Turn the power supply before performing installation or wiring. Turn the power supply before removing the terminal cover. Do not connect anything to unused terminals. Correct Use Perform wiring with crimp terminals that are suitable for M. screws. Install the product as far away as possible from devices that generate strong high-frequency noise (e.g., high-frequency welders) or surges. Do not pull on the USB cable. Doing so may cause the cable to come loose. ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by 0.0. Cat. No. N0-E-0A OMR Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku Kyoto, Japan Tel: (8)--08/Fax: (8)--89 Printed in Japan M (A) 8

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models Interface Converter CSM DS_E 1 A compact converter that allows communications between /USB and RS-/ devices. Ideal for industrial applications. Allows communications between /USB (Universal Serial Bus)

More information

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models Interface Converter CSM DS_E 1 A compact converter that allows communications between /USB and RS-22/8 devices. Ideal for industrial applications. Allows communications between /USB (Universal Serial Bus)

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket Solid-state Timer Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating modes. Conforms

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges Solid-state Timer Miniature Timer Compatible with the MY Relay Large transparent time-setting knob facilitates time setting. Flat-blade and Phillips screwdrivers can also be used for time setting. Approved

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren Solid-state Power OFF-delay Timer II DIN 22.5-mm Solid-state Power OFF-delay Timer High immunity to invertor noise. Long power OFF-delay times; S-series: up to 12 seconds, L-series: up to 120 seconds.

More information

SRT2-ROC08, SRT2-ROC16

SRT2-ROC08, SRT2-ROC16 Ultra-miniature 8-point and 16-point Relaymounted Terminals Ultra-compact (8-point models: 101 x 51 x 51 mm (W x H x D); 16-point models: 156 x 51 x 51 mm (W x H x D)) MOS FET Relay and Relay models. DIN

More information

Three-phase Phase-sequence Phase-loss Relay

Three-phase Phase-sequence Phase-loss Relay Three-phase Phase-sequence Phase-loss Relay K8AB-PM Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. Monitor overvoltages, undervoltages, phase sequence, and phase loss

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30 Sensing distance Supply voltage Output 4 mm 8 mm 12 to 24 VDC 100 to 220 VAC 200 ma max. 100 ma max. Proximity Sensor Detects Objects without Being Influenced by Aluminum and Cast Iron Cut Chips Sense

More information

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA Ideal for 3-phase voltage asymmetry monitoring for industrial facilities and equipment. Monitor voltage asymmetry, phase sequence, and

More information

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting Solid-state Timer DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display Dual power supplies for free AC/DC. Eight operation modes selectable with one unit. Any desired time can be

More information

Single-phase Voltage Relay

Single-phase Voltage Relay Single-phase Voltage Relay K8AB-VW Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages and undervoltages simultaneously. Separate settings and outputs supported

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Switching Power Supply Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W Models range from 10 to 600 W UL 508 approval on 100-W 150-W, 300-W, and 600-W models Wide range of output

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

Switch Mode Power Supply

Switch Mode Power Supply Switch Mode Power Supply S8JX (/0/100/10-W Models) Compact Power Supply Compliant with Global Standards Output voltages of V, 12 V, and 2 V are available for between to 10 W capacity (100 W, 10 W: 2-V

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC Switching Power Supply DIN-Rail Mount Power Supply With Capacity Up to 240 W for General or Industrial Applications Wide power range: 15 to 240 W 15 W and PFC Models with Universal voltage of 100 to 230

More information

Safety Relay Unit (I/O Unit Type)

Safety Relay Unit (I/O Unit Type) Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Model Number Structure

Model Number Structure Solid-state Twin Timers CSM DS_E_1_5 DIN 48 48-mm Twin Timers Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. ON- and OFF-times can be set independently and so combinations of

More information

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer Solid-state Power OFF-delay Timer H3CR-H DIN 48 x 48-mm Solid-state Power OFF-delay Timer Long power OFF-delay times; S-series: up to 12 seconds, M-series: up to 12 minutes. Models with forced-reset input

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC Solid-state Timer CSM DS_E_4_1 Miniature Timer Compatible with the MY Relay Semi-multi power supply voltage. Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver

More information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21 Solid-state timer CSM DS_E_3_2 Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating

More information

Handheld Reader Writer

Handheld Reader Writer Handheld Reader Writer CH1D-V2 A Compact Lightweight Easy-to-use Pen-type Reader Writer. Connects directly to a personal computer or PLC via RS-232C. The Reader Writer s protective construction is IP63

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Appendix 3 Using NS-AL002 Converters

Appendix 3 Using NS-AL002 Converters Appendix 3 Using Converters The RS-232C/RS-422A Converter is connected directly to RS-232C port A or B of the, and converts RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix

More information

I/O delay. (0.32 in ±0.06 in)

I/O delay. (0.32 in ±0.06 in) R Inductive Power Couplers Allows Wireless Transmission of ON/OFF Signals from Input Devices and Power to Input Devices H Use the electromagnetic coupler to transmit input signals to the B7A Output Unit

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_4_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output Solid-state Timer H3FA Please read and understand this catalog before purchasing the products. Please consult OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

Model Number Structure

Model Number Structure Temperature Controllers Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for temperature

More information

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend. Door Interlock Switch Power Switch with Minimum Contact Gap of 3 mm Offers the minimum contact gap of 3 mm required for power switches as standard equipment. Highly reliable design conforms to European

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

SYSMAC Remote Transistor Module

SYSMAC Remote Transistor Module 9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

NX integrated safety System configuration. Integrated safety into machine automation

NX integrated safety System configuration. Integrated safety into machine automation NX-S@ NX integrated safety Integrated safety into machine automation The safety controller meets Category 4, PLe according to the ISO 13849-1 and SIL3 according to the IEC 61508 Flexible system lets you

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width

More information

Model Number Structure

Model Number Structure Temperature Controllers ECS CSM_ECS_DS_E Simple Functions in DIN mm-size Plug-in Temperature Controllers Easy setting using DIP switch. Models with two alarms added to Series, ideal for applications requiring

More information

Special-purpose Basic Switch

Special-purpose Basic Switch Special-purpose Basic Switch DPDT Basic Switch for Two Independent Circuit Control Incorporates two completely independent built-in switches. Ideal for switching the circuits operating on two different

More information

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC) Solid-state Relay Compact SSRs Ideal for Built-in Applications Vertical, compact SSRs with an operation indicator offered in versatile variations. Can be mounted side by side with an electromagnetic relay

More information

Appendix G. CJ1W-CIF11 RS-422A Converter

Appendix G. CJ1W-CIF11 RS-422A Converter CJ1W-CIF11 RS-422A Converter The CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C port and converts RS- 232C to RS-422A/485. Specifications General Specifications Item Specification

More information

Energy Management BUS Adapter Type VMU-B

Energy Management BUS Adapter Type VMU-B Energy Management BUS Adapter Type RS485 (Modbus) to M-Bus communication adapter EM24-DIN and EM21-72D self recognition Front diagnostic LED s Universal 18 to 260 VAC/DC power supply Dimensions: 1-DIN

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Miniature, Thin Power Supply to Be Built into Equipment Half the size of OMRON s conventional power supply. PCB-type and connector-type models available. UL, CSA approved. Conforming

More information

Multipoint Temperature Controller E5ZE

Multipoint Temperature Controller E5ZE Multipoint Temperature Controller E5ZE Compact, Easy-to-mount Multipoint Temperature Controller (Casing) Compact, Easy-to-use, Board-type Multipoint Temperature Controller (Open) Easy-to-mount, user-friendly

More information

E2Q4 Square Proximity Sensor

E2Q4 Square Proximity Sensor Inductive Square Slim, compact size M2 Plug-in connection Integrated short circuit and reverse polarity protection Active face positioning: Y-axis 5, X-axis 90 incremets Ordering Information DC type Connection

More information

D2SW-3L1HS D2SW-01L1HS

D2SW-3L1HS D2SW-01L1HS Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures

More information

Energy Management BUS Adapter Type VMU-B 01

Energy Management BUS Adapter Type VMU-B 01 Energy Management BUS Adapter Type VMU-B 01 RS485 (Modbus) to M-Bus communication adapter EM21-72D, EM24-DIN and EM33-DIN self recognition Front diagnostic LED s Universal 18 to 260 VAC/DC power supply

More information

DIN Track Mounted, Standard 22.5-mm Width Timer Range

DIN Track Mounted, Standard 22.5-mm Width Timer Range 22.5 mm Timer DIN Track Mounted, Standard 22.5-mm Width Timer Range A wide AC/DC power supply range (24 to 240 VAC/DC) reduces the number of r models kept in stock. Terminal clamp left open when delivered.

More information

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0. Built-in Amplifier Photoelectric Sensor E3V3 Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance. A series of models with an M8 metal junction connector

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

Three-phase Phase-sequence Phase-loss Relay

Three-phase Phase-sequence Phase-loss Relay Three-phase Phase-sequence Phase-loss Relay K8AB-PM Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. Monitor overvoltages, undervoltages, phase sequence, and phase loss

More information

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are Safety Relay Unit The G9SA Series Offers a Complete Line of Compact Units H Several types of -mm wide Units are available: a -pole model, a -pole model, models with poles and OFF-delay poles H 7.-mm wide

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal.

More information

AI561 Analog Input Module

AI561 Analog Input Module Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968

More information

1/32 DIN Digital Panel Meter K3GN

1/32 DIN Digital Panel Meter K3GN 1/32 DIN Digital Panel Meter Compact and Intelligent Digital Panel Meter Accepts Process Voltage/Current, Frequency and Digital Data Display. Simply configurable through the front panel or via RS-485.

More information

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output Characteristics off-delay timing relay - control - 1 s..100 h - 24..240 V - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type

More information

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever Basic Switch MINIATURE Watertight Miniature Basic Switch High-quality watertight, high-precision miniature basic switch meets IP67 requirements IEC 529 (lead wire type) Monoblock construction assures high

More information

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower

More information

F150 Vision Controller with integrated PROFIBUS-DP unit. 9-pin female sub-d connector (RS-485 ProfiBus) Bus termination

F150 Vision Controller with integrated PROFIBUS-DP unit. 9-pin female sub-d connector (RS-485 ProfiBus) Bus termination PNSPO F150 Vision Controller PROFIBUS-DP Unit F150-C15E-3-PRT F150 Vision Controller with integrated PROFIBUS-DP unit Main features PROFIBUS setting fully integrated into F150 user menu Auto-detection

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

Communications & Networking

Communications & Networking is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave

More information

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input) Temperature Controllers CSM DS_E Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. s with two alarms added to Series, ideal for temperature

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Switch Mode Power Supply S8VT 120/240/480/960 W Models Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output

More information

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings. Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Three-phase Voltage Relay

More information

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit) Temperature Controller DIN-sized (48 x 48 mm) Temperature Controller With Digital Setting Compact, low-cost Temperature Controller Incorporates proportional adjustment and reset adjustment function. Incorporates

More information

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Sensing distance 1.0 mm 1.5 mm 2.5 mm 5.0 mm High-precision Proximity Sensor Supply voltage 12 to 24 VDC Output 100 ma max., 2 outputs Ideal for Positioning and Discriminating Objects Assures minimal temperature

More information

Solid-state Timers H3DK

Solid-state Timers H3DK New Product News Solid-state Timers H3DK DIN Track-mounted, 22.5-mm-width Standard Timer Series LR A wide AC/DC power supply range (24 to 240 VAC/DC).*1 All sub-series include models with 12-VDC power

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F) MOS FET Relay G3VM- XN(F)/4N(F) SSR for Switching Analog Signals, with an I/O Dielectric Strength of 2.5 kvac Using Optical Isolation Switches minute analog signals. Linear voltage and current characteristics.

More information

Solid-state Timers H3DK

Solid-state Timers H3DK New Product News Solid-state Timers H3DK DIN Track-mounted, 22.5-mm-width Standard Timer Series A wide AC/DC power supply range (24 to 240 VAC/DC). *1 All sub-series include models with 12-VDC power supply.

More information

Temperature/Process Meter

Temperature/Process Meter Temperature/Process Meter High-Performance Temperature Meter Accepts Temperature/Analog Inputs Multi-range capability: a single processor connects 14 types of sensors with varying current/voltage Programmable

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB Subminiature Basic Switch SS-P SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept Insert molded base and improved case-to-base seal provides enhanced resistance to

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information