Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

Size: px
Start display at page:

Download "Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from"

Transcription

1 Interface RS485-TTL v.1.0 CODE: EN* Edition: 3 from Supersedes the: 2 from

2 TABLE OF CONTENTS 1. General description Components arrangements Connection to the RS485 bus System structure in the RS485 bus Connecting the interface to the bus Configuration of power supplies Configuration of power supplies of PSBEN series with LCD display Setting the communication address Setting the transmission parameters Configuration of power supplies of PSBEN series with LED display Setting the communication address Setting the transmission speed and parity of the transmission Configuration of power supplies of EN54 series with LCD display Setting the communication address Setting the transmission parameters Configuration of power supplies of EN54 series with LED display Setting the communication address Setting the transmission speed Setting the parity of the transmission Technical parameters

3 Features: power supply via the SERIAL socket connection of the PSU of PSBEN or EN54 series with the RS485 bus easy connection galvanic isolation half-duplex communication system cooperation with PowerSecurity program optical indication warranty - 5 years from the production date 1. General description. The RS485-TTL interface enables connecting the PSU of PSBEN and EN54 series to the RS485 bus with full galvanic isolation. The RS485 bus is a two-wire, differential, half-duplex communications bus, where transmitting and receiving data is alternate 2. Components arrangements. The picture below shows the arrangement of the most important components and connectors of the RS485-TTL interface on the PCB. Fig.1. The view of the RS485-TTL interface. Table 1. Description of the components. Element Description No. Connector of the RS485 bus [1] A+, B- - RS485 data transmission SG - signal ground [2] TTL cable for connection with the PSU LEDs optical indication: PWR supply voltage indication [3] TX data transmission RX receiving data 3

4 3. Connection to the RS485 bus System structure in the RS485 bus. Use a twisted-pair cable as a transmission wire of the bus. The point-to-point topology is recommended, while the star topology should be avoided. If the wires are long enough, it is recommended to use shielded cables to avoid errors during the communication and to lower the susceptibility to noise and radio interference. It is recommended to mount the terminal resistors at the ends of the bus with a resistance close to the impedance of the used cable, which is 120 Ohm. A block diagram of the RS485 bus with RS485-TTL interfaces housed in the enclosures of power supplies of PSBEN and EN54 series is presented below. Fig. 2. The block diagram of the power supplies with RS485-TTL interface connected to the RS485 bus A selected location for mounting the interfaces is provided inside the enclosure of the PSU. The connection with the power supply unit should use the additional TTL cable supplied with the interface. The TTL cable should be connected to the SERIAL sockets that are located both on the interface and the PCB of the PSU. The connection with the RS485 bus uses the RS-485 connector located on the PCB of the interface. Connect the wires of the RS485 bus, marked and connected the same way as the rest of devices (A+ to A+, B- to B-), to the A+ and B- terminals of the connector. Data conversion between the RS485 bus and the computer is implemented by the INTUR interface, also offered by PULSAR Connecting the interface to the bus. 1) Mount the RS485-TTL interface in a selected location of the PSU. 2) Connect the interface to the PSU using the additional TTL cable (included in the interface kit) and plugging it in the SERIAL sockets. 3) Connect the RS485 bus cable to the RS-485 connector of the interface. Make sure that the cables are connected in the same way as other devices, i.e. A+ to A+, B- to B-. In case of shielded wires, the shield should be connected to the SG signal ground terminals. 4) Optionally, mount the 120 Ohm terminal resistors at the end of the RS485 bus. 5) Connect the USB-RS485 interface converting data from the RS485 bus to a USB standard. This interface is offered by PULSAR. 6) Assign an address to each PSU in the bus. Addresses cannot be repeated. 7) Configure the connection in PowerSecurity program. PowerSecurity program is available on: 4

5 4. Configuration of power supplies. Communication in the RS485 bus requires setting appropriate communication parameters in all devices and assigning of unique addresses. The configuration of power supplies uses a display located on the front panel of the enclosure. Depending on the display type - LED or LCD - the procedure for changing the settings is different. 4.1 Configuration of power supplies of PSBEN series with LCD display The PSU fitted with LCD display enables setting the communication parameters of the serial port from the LCD panel. To enter the setup mode, press the SET button from the main screen Setting the communication address All power supplies are factory-set to address 1. - enter the Settings menu of the PSU (if the main screen is displayed, press the SET button) - use the < or > buttons to display the PSU menu - confirm by pressing SET - use the < or > buttons to choose the Communication address - press the SET button - the prompt will appear at the end of the line - use the < or > buttons to set the address from 1 to confirm by pressing the SET button 5

6 4.1.2 Setting the transmission parameters - use the < or > buttons to display the PSU menu - press the SET button - use the < or > buttons to display the Transmission menu (The Transmission menu is at the bottom of the screen) - press the SET button, the prompt will appear at the end of the line - use the > or < buttons to set the 19.2k 8E1 - confirm by pressing the "SET" button 6

7 4.2 Configuration of power supplies of PSBEN series with LED display The PSU fitted with LED display enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the <,> rightmost and leftmost buttons Setting the communication address All power supplies are factory-set to address 1 simultaneously press the <,> rightmost and leftmost buttons on the LED panel - press OK once the Adr parameter is displayed - use the < or > buttons in order to set the address from 1 to confirm the selected address by pressing OK. - in order to return to the main menu, simultaneously press the <,> rightmost and leftmost buttons 7

8 4.2.2 Setting the transmission speed and parity of the transmission The PSU fitted with LED display enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the <,> rightmost and leftmost buttons. Depending on the displayed information, the following parameters can be set: Adr the device address, trs transmission speed, trp transmission parameters. simultaneously press the <,> rightmost and leftmost buttons on the LED panel - The Adr parameter will be displayed, - press the right arrow > - The trs parameter will be displayed - press OK. - The display will show one of the two parameters: 9.6 or 19.2 informing about the selected transmission speed - use the < or > buttons in order to set the transmission speed to 19200, displayed as confirm by pressing OK - The trs parameter will be displayed again - press the right arrow > - press "OK" when trp is displayed - The display will show one of the three parameters: 8n2, 8E1 or 8o1 - use the < or > buttons in order to set the 8E1 parameter - confirm by pressing OK. - Simultaneously press the <,> rightmost and leftmost buttons to complete the configuration procedure 8

9 4.3 Configuration of power supplies of EN54 series with LCD display The PSU fitted with LCD display enables setting the communication parameters of the serial port from the LCD panel. To enter the setup mode, press the SET button from the main screen Setting the communication address - use the < or > buttons to display the PSU menu - press the SET button - use the < or > buttons to choose the Communication address menu - press the SET button, the prompt will appear at the end of the line - use the < or > buttons to set the address address of the PSU during the communication with the computer - confirm by pressing the SET button 9

10 4.3.2 Setting the transmission parameters - use the < or > buttons to display the PSU menu - press the SET button - use the < or > buttons to display the Transmission menu (The Transmission menu is at the bottom of the screen) - press the SET button, the prompt will appear at the end of the line - use the > or < buttons to set the 19.2k 8E1 - confirm by pressing the SET button 10

11 4.4 Configuration of power supplies of EN54 series with LED display The PSU fitted with LED display enables setting the communication parameters of the serial port from the LED panel. To enter the setup mode, simultaneously press the <,> rightmost and leftmost buttons Setting the communication address - simultaneously press the <,> rightmost and leftmost buttons - The tst parameter will be displayed - use the < or > buttons to display the Adr parameter - press OK - The current address of the PSU will be displayed - use the < or > buttons in order to set the address address of the PSU during the communication with the computer - confirm by pressing OK - in order to return to the main menu, simultaneously press the <,> rightmost and leftmost buttons 11

12 4.4.2 Setting the transmission speed. - simultaneously press the <,> rightmost and leftmost buttons - The tst parameter will be displayed - use the < or > buttons to display the trs parameter - press OK - The information about the transmission speed will be displayed - use the < or > buttons in order to set the required transmission speed, - 9.6k : k (factory setting) - confirm by pressing OK - in order to return to the main menu, simultaneously press the <,> rightmost and leftmost button Setting the parity of the transmission. - simultaneously press the <,> rightmost and leftmost buttons - The tst parameter will be displayed - use the < or > buttons to display the trp parameter - press OK - The information about the parity of the transmission will be displayed on the panel 12

13 - use the < or > buttons in order to set the required communication mode, - 8N2-8E1 (factory setting) - 8O1 - confirm by pressing OK - in order to return to the main menu, simultaneously press the <,> rightmost and leftmost buttons 5. Technical parameters. Power supply Current consumption Transmission speed Galvanic isolation between the RS485 and TTL interface: Optical indication Operating conditions Dimensions (LxWxH) Net/Gross weight Storage temperature 5V Max. 30mA Max bauds, parity check 1KV(DC), 700V(AC) PWR supply voltage indication (red LED) TX data transmission (yellow LED) RX receiving data (green LED) Temperature -10 o C 40 o C Relative humidity 20%...90% 63 x 50 x 20 [mm] 0,03kg / 0,09kg -20ºC...+60ºC 13

14 WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. WARRANTY 5 years from the production date. WARRANTY IS VALID only upon presentation of the original invoice. Pulsar K.Bogusz Sp.j. Siedlec 150, Łapczyca, Poland Phone (+48) , Fax. (+48) biuro@pulsar.pl, sales@pulsar.pl

Interface RS485-WiFi

Interface RS485-WiFi Interface RS485-WiFi v.1.0 CODE: EN Edition: 1st (6th Jan 2013) CONTENTS 1. General description....2 2. Arrangement of the components....3 3. Installation...4 3.1 Main guidelines....4 3.2 Connecting to

More information

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition Interface WI-FI v.1.0 CODE: EN Edition: 2 from 19.12.2012 Supersedes the: 1 from 07.09.2012 edition CONTENTS 1. General description....3 2. Arrangement of the components....3 3. Installation...4 4. Configuration

More information

Features: Example of use

Features: Example of use RS64 v1.0 RS64 6-ports switch with power supply for 4 IP cameras, RACK Edition: 1 from 10.01.2018 Supercedes the edition: ---------- EN** Features: Switch 6 ports 4 PoE ports 10/100Mb/s (data transfer

More information

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible

More information

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply Edition: 1 from 1.05.2016 Supercedes the edition: ------------ EN Features: power supply of 4 IP cameras (48VDC) 5 10/100

More information

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space Edition: 2 from 05.04.2018 Supercedes the edition: 1 from 04.09.2017 EN** Features: Switch 10 ports 8 PoE ports

More information

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from BNC08128C v.1.0 BNC 13,8V/8x1A/17Ah Switch mode buffer power supply unit for CCTV. EN** Edition: 3 from 15.05.2014 Supersedes the edition: 2 from 25.03.2014 GREEN POWER CCTV BNC PSU features: DC 13,8V/8x1A

More information

PSBEN 10A12E. PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3.

PSBEN 10A12E. PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3. PSBEN 10A12E v.1.1 PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3. EN** Edition: 7 from 02.11.2017 Supercedes edition: 6 from 02.02.2015 LED Version TABLE OF CONTENTS 1. PSU FEATURES....

More information

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras Edition: 4 from 15.11.2017 Supercedes the edition: 3 from 30.03.2017 EN** Features: Uninterruptible power supply

More information

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras

More information

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras Edition: 3 from 07.03.2018 Supercedes the edition: 2 from 15.11.2017 EN** Features: Uninterruptible power

More information

PSBOC PSBOC 27,6V/5,5A/OC

PSBOC PSBOC 27,6V/5,5A/OC v.1.1 PSBOC 27,6V/5,5A/OC Enclosed buffer switch mode power supply unit with technical outputs. EN** Edition: 8 from 01.06.2016 Supercedes edition: 7 from 10.04.2015 Features: 27,6VDC/5,5A uninterrupted

More information

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j. User manual ADA-4010 RS-485 / RS-422 to RS-232 Converter Copyright 2001-2017 CEL-MAR spj 1 io_ada-4010_v322_en Contents 1 GENERAL INFORMATION 3 11 WARRANTED INFORMATION 3 12 GENERAL CONDITIONS FOR SAFE

More information

Buffer power supply units. compliant with EN are intended to alarm system devices

Buffer power supply units. compliant with EN are intended to alarm system devices Buffer power supply units compliant with EN 50131-6 are intended to alarm system devices Buffer power supply PSBEN series Additional functions of the LCD series BLACK POWER current parameters of the PSU

More information

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3 KOD: TYP: PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU EN BLACK POWER This product is suitable for the systems designed in compliance with the PN-EN 50131-6 grade 1, 2 or 3

More information

RS-485 module. Data sheet. for electricity meters

RS-485 module. Data sheet. for electricity meters Data sheet RS-485 module for electricity meters RS-485 electrical interface for direct access to meter(s) Share GSM/GPRS modem connect up to 32 electricity meters Galvanically separated serial communication

More information

EN54-2A17. EN54 27,6V/2A/2x17Ah power supply for fire alarm systems

EN54-2A17. EN54 27,6V/2A/2x17Ah power supply for fire alarm systems EN54-2A17 v.1.0 EN54 27,6V/2A/2x17Ah power supply for fire alarm systems EN** Edition: 3 from 26.08.2014 Supersedes the edition: 2 from 02.06.2014 LED Version TABLE OF CONTENTS 1. PSU FEATURES:... 4 2.

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3 CODE: TYPE: PSBEN 5024C EN** v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit BLACK POWER Functional requirements This product is suitable for the systems designed in compliance

More information

TRP-C08 User s Manual

TRP-C08 User s Manual TRP-C08 User s Manual USB To RS232/422/485 Optical Isolated Converter Printed Aug. 2005 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu Street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3 CODE: TYPE: EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. BLACK POWER H H 1 W W 1 D 1 D Functional requirements This product is suitable for the systems

More information

PSBEN 3012C. PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit.

PSBEN 3012C. PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit. PSBEN 3012C v.1.0 PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit. EN Edition: 2nd (14th Sep 2012) Supersedes the: 1st (25th April 2012) edition CONTENTS 1. FUNCTIONAL REQUIREMENTS OF THE

More information

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3 CODE: TYPE: PSBEN 5024C/LCD EN** v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit BLACK POWER Functional requirements This product is suitable for the systems designed in compliance

More information

Media Converters. Media Converters. Product Selection Guides

Media Converters. Media Converters. Product Selection Guides Product Selection Guides Media Converters Serial-to-Fiber Converter Selection Guide....................................-2 Serial-to-Serial Converter Selection Guide...................................-3

More information

PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3 CODE: TYPE: PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. EN** BLACK POWER H H 1 W W 1 D 1 D Functional requirements This product is suitable for the systems

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

Moxa TCC-100 Series User s Guide

Moxa TCC-100 Series User s Guide Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

ADA-4040A. User manual ADA-4040A. Addressable RS485 / RS422 Baud Rate Converter. Copyright CEL-MAR sp.j. 1 io_ada-4040a_v4.

ADA-4040A. User manual ADA-4040A. Addressable RS485 / RS422 Baud Rate Converter. Copyright CEL-MAR sp.j. 1 io_ada-4040a_v4. User manual Addressable Baud Rate Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-4040a_v4.02_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS FOR SAFE

More information

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L. CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / 1.5.9 CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / 7.5.9 CMU 100 / 7.M.9 CMU 100 / 7.L.9-0 0 0 0 0 0 CMU 100 - RS485 to Ethernet Converter Content

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4 TRP-C08 USB to RS232/422/485 Isolated Converter User s Manual Printed Sep.2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

AUD-220 Installation Guide

AUD-220 Installation Guide AUD-220 Installation Guide STEREO MONO BRIDGE IR RS232 TX RX MIC 48V LINE L R MIC 1 2 INPUTS 24V DC 1 x 40W @ 8Ω 2 x 20W @ 4Ω LOOP OUTPUTS The Intelix AUD-220 is a 2x20 watt Class D amplifier with 8Ω speaker

More information

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00 ABB Drives User s Manual RS-485 Adapter Board FRSA-00 Table of Contents 1 INTRODUCTION... 2 1.1 Overview... 2 1.2 Technical Data of RS-485 Link... 2 1.3 RS-485 Bus Topology... 2 2 INSTALLATION... 2 2.1

More information

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2

TRP-C08S. USB To 1* RS232 and 1*RS422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.2 TRP-C08S USB To 1* RS232 and 1*RS422/485 Isolated Converter User s Manual Printed Jun. 2007 Rev 1.2 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual TRP-C08S USB to 1 RS232 and 1 RS422/485 Isolated Converter User s Manual Printed Sep. 2014 Rev 1.4 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

RS485 MODBUS Module 6RO

RS485 MODBUS Module 6RO Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Installation Instructions

Installation Instructions TM Installation Instructions Manual 10 - Star Driver Modules PY-STR, PY-STR-L, PY-STR-H and PY-STR-2-H Read also: Installation Instructions, Manual 2 - Network Wiring Please read this manual completely

More information

AUD-340 Installation Guide

AUD-340 Installation Guide F0123456789ABC DE AUD-340 Installation Guide INPUTS CONTROL OUTPUT 24V DC 48V LINE 2 AUDIO IR RS232 COM 70V 100V 1 3 DIGITAL L R AUDIO 2.5A MAX TX RX 1 2 3 INPUT SELECT LINE BASS TREBLE MUTE 1 Safety Precautions

More information

GE Fanuc IC694ALG221. Rx3i PacSystem

GE Fanuc IC694ALG221. Rx3i PacSystem GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com

More information

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following

More information

ADA User Manual ADA Separator - Repeater RS-232. io_ada-1010_v3.20_en. Copyright CEL-MAR sp.j.

ADA User Manual ADA Separator - Repeater RS-232. io_ada-1010_v3.20_en. Copyright CEL-MAR sp.j. User Manual Separator - Repeater RS- Copyright 001-01 CEL-MAR sp.j. 1 io_ada-1010_v.0_en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...

More information

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default

More information

TRP-C07 User s Manual

TRP-C07 User s Manual TRP-C07 User s Manual RS-422/485 Isolated Repeater Printed Feb. 2007 Rev 1.1 Trycom Technology Co.,Ltd 1F, No.2-11,Sihu street,yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems CODE: TYPE: EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems EN** RED POWER 1438 Certificate of constancy of performance CNBOP-PIB No 1438-CPR-0385 Certificate of admittance

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Moxa TCC-100 Series Hardware Installation Guide

Moxa TCC-100 Series Hardware Installation Guide Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide

More information

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01 ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

PSBEN 2012B/LCD. PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit.

PSBEN 2012B/LCD. PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit. PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit. EN Edition: 4 from 01.02.2013 Supersedes the: 3 from 20.11.2012edition CONTENTS 1. FUNCTIONAL REQUIREMENTS OF THE

More information

R507 I.S. Interface Module User Manual

R507 I.S. Interface Module User Manual R507 I.S. Interface Module R507 I.S. Interface Module User Manual Contact Mercury HMI Ltd George House Derwent Road Malton North Yorkshire YO17 6YB Page 2 of 14 Tel: +44 (0) 1653 697200 Fax: +44 (0) 8700

More information

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual VirtualSCADA USB to RS422/485 Isolated Converter User Manual Revision 1.01.00 Page 1 (15) Table of contents Warranty and support... 3 Product return... 3 1 About the VirtualSCADA USB to RS422/485 Converter...

More information

ADA User manual ADA RS-232 to Multidrop Fiber Optic Converter. 1 io_ada-7210_en_v3.17. Copyright CEL-MAR sp.j.

ADA User manual ADA RS-232 to Multidrop Fiber Optic Converter. 1 io_ada-7210_en_v3.17. Copyright CEL-MAR sp.j. User manual ADA-7210 RS-232 to Multidrop Fiber Optic Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-7210_en_v3.17 Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

PSBEN 5012D/LCD. PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit.

PSBEN 5012D/LCD. PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit. PSBEN 5012D/LCD v.1.0 PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit. EN Edition: 2nd (14th Sep 2012) Supersedes the: 1st (25th April 2012) edition CONTENTS 1. FUNCTIONAL REQUIREMENTS

More information

icex-cmtm General specs and Installation guide

icex-cmtm General specs and Installation guide icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB

More information

RS485 MODBUS Module 8AO

RS485 MODBUS Module 8AO Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

v.1.1/iv EN54 27,6V/7A/2x40Ah power supply for fire alarm systems

v.1.1/iv EN54 27,6V/7A/2x40Ah power supply for fire alarm systems CODE: TYPE: EN54-7A40 v.1.1/iv EN** EN54 27,6V/7A/2x40Ah power supply for fire alarm systems RED POW ER This product is suitable for the systems designed in compliance with the standards EN 54-4 and EN

More information

Island bus expansion module

Island bus expansion module s 8 184 8184P01 TX-I/O Island bus expansion TXA1.IBE Expand island bus to a distance of up to 2 x 200 meters Compact design per DIN 43 880, requires little space Easy installation and setup Mounted on

More information

DTM Distributed Transmitter Monitor

DTM Distributed Transmitter Monitor Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration

More information

Extension module for graphic Web functions for one automation station

Extension module for graphic Web functions for one automation station s 9 266 9263p01 DESIGO PX Extension module for graphic Web functions for one automation station Plugs into the modular automation stations, type PXC...-U For operation of the PXC -U automation stations

More information

Strain Gauge Converter

Strain Gauge Converter EN Z-SG General Description Module Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output.

More information

Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual

Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual http://www.fourstar-dy.com Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual FOURSTAR Electronic Technology Co., Ltd. All rights reserved Contents Preface.... 3 Copyright....3 Version

More information

TRP-C06H User s Manual

TRP-C06H User s Manual TRP-C06H User s Manual 2-Port RS-232 to RS-422/485 Isolated Converter Printed Feb.2007 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Hinge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

Extension module for Web functions generic

Extension module for Web functions generic s 9 264 9263p01 DESIGO PX Extension module for Web functions generic Plugs into the modular automation stations, type PXC...-U PXA30-W1 Extension module for PXC -U automation stations in the DESIGO building

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

ISE 021 S-DIAS Interface Module RS232 / RS485

ISE 021 S-DIAS Interface Module RS232 / RS485 ISE 021 S-DIAS Interface Module RS232 / RS485 Date of creation: 23.04.2014 Version date: 31.01.2018 Article number: 20-101-021-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321

More information

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0

TRP-C08M. USB To 4 RS232/422/485 Isolated Converter. User s Manual. Printed Jun Rev 1.0 TRP-C08M USB To 4 RS232/422/485 Isolated Converter User s Manual Printed Jun. 2013 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191,

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a

More information

RS485 MODBUS Module 8I8RO

RS485 MODBUS Module 8I8RO Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS Serial Communications Accessories SITRANS RD200/300 Operating Instructions 05/2013 SITRANS Siemens Auto SIT SITRANS RD300RANS RD300 Safety Guidelines: Warning notices must be observed to ensure personal

More information

User s Manual Printed Sep Rev 1.2

User s Manual Printed Sep Rev 1.2 TRP-C08M USB To 4 RS232/422/485 Isolated Converter User s Manual Printed Sep. 2014 Rev 1.2 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

CS485. User s Manual. Version ZYPEX, Inc.

CS485. User s Manual. Version ZYPEX, Inc. CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

Extension module for BACnet over Ethernet / IP and graphic Web functions

Extension module for BACnet over Ethernet / IP and graphic Web functions s 9 265 9263p01 DESIGO PX Extension module for BACnet over Ethernet / IP and graphic Web functions Plugs into the modular automation stations, type PXC...-U PXA30-W2 For operation of the PXC -U automation

More information

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO Hardware Manual CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO The expert for industrial and automotive communication IXXAT Headquarter US Sales Office IXXAT Automation GmbH IXXAT Inc. Leibnizstr. 15

More information

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3 Display User's Manual Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"

More information

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248 Our Products: USB High Speed - High Isolated - Industry Converter Interfaces Highest quality - on the basis of our experience - we not accept compromise! USB 2.0 - RS485 High Isolated Industry Converter

More information

ADA-I9140. User manual ADA-I9140. USB to RS-485 / RS-422 converter. 1 io_ada-i9140_v3.24_en. Copyright CEL-MAR sp.j.

ADA-I9140. User manual ADA-I9140. USB to RS-485 / RS-422 converter. 1 io_ada-i9140_v3.24_en. Copyright CEL-MAR sp.j. User manual ADA-I9140 to RS-485 / RS-422 converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-i9140_v3.24_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS

More information

MEV Limited USB232/485 INSTRUCTION MANUAL

MEV Limited USB232/485 INSTRUCTION MANUAL MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

SCB-C08 USB to RS232/422/485 Converter

SCB-C08 USB to RS232/422/485 Converter SCB-C08 USB to RS232/422/485 Converter USB Interface RS-232 signal RS-422 signal: RS-485 signal: Cable Type Transmission distance Signal LED Direct power from USB port Power consumption: Compliant with

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL WA-1 MINI Product code: 304-01-01 *Explanatory figure Table of Contents 1. Manufacturer... 3 2. Specifications... 3 3. Transport and storage... 3 4. Device construction...

More information

JVA Z Series Keypad Bus Wiring Installation Manual

JVA Z Series Keypad Bus Wiring Installation Manual JVA Z Series Keypad Bus Wiring Version: 1.21 Date: 1 June 2015 By: Miles Norton JVA Technologies Pty Ltd 2013 Version July 2013. Uncontrolled if printed Introducing the Keypad Bus Table of Contents 1 Introducing

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface

More information

M-Bus Master MultiPort 250D/L

M-Bus Master MultiPort 250D/L M-Bus Master MultiPort 250D/L Remote reading with M-Bus Up to 250 meters per M-Bus Master and by cascading, up to 1250 meters in a system Supporting primary/secondary/enhanced secondary addressing and

More information

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials Options, cables and accessories scancontrol 2x0/29x0 Options*: /SI Integrated sensor ON/OFF /PT Pigtail cable Hardware ON/OFF of the laser line 0.2m long cable directly out of the sensor /3B Class 3B /BL

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

KVM Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB 2.0 Link Up To 200 Meters

KVM Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB 2.0 Link Up To 200 Meters Description APAC KVM200-2LC extender enables DVI and USB 2.0 extension up to 200 meters over duplex multi-mode fibers. KVM200-2LC provides a high quality and uncompressed video transmission, also additional

More information

I-7570 Serial To HART Converter

I-7570 Serial To HART Converter I-7570 Serial To HART Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original

More information

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 16I-M Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount Fiber-Optic Link to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount 101-0079 Installation Operation & Specifications Manual Auto-direcon control Supports BAUD rates up to 115,200 Fiber

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for Version 1.2 20.01.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

NetBiter I/O Extender User Manual

NetBiter I/O Extender User Manual User Manual Part no. 0920-9999-009 IntelliCom Innovation AB Pilefeltsgatan 73 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision

More information

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001 Installation Guide DOC.050523-EM400X -1- The information contained in this document is subject to change without prior notice. Copyright (C) All

More information

Proposal for SAS 2.x Specification to Enable Support for Active Cables

Proposal for SAS 2.x Specification to Enable Support for Active Cables 08-052r2 Proposal for SAS 2.x Specification to Enable Support for Active Cables Gourgen Oganessyan QUELLAN March 7, 2008 Introduction Inclusion of active cable interconnect option into the SAS specification

More information

USB RS485/RS422 Converter INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8

USB RS485/RS422 Converter  INTRODUCTION USB-i485 USB-i485 SPECIFICATIONS USB-i485 USB-i485 NOVUS AUTOMATION 1/8 NOVUS AUTOMATION 1/8 USB DRIVER INSTALLATION USB-i485 The following installation steps may be slightly different depending on your PC configuration and Windows version. Follow the Wizard instructions and

More information