glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Size: px
Start display at page:

Download "glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA"

Transcription

1 99 glide air cooled liquid chillers ND free cooling chillers glider Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING

2 100 air cooled liquid chiller and free cooling chillers VERSIONS : (R134a) Cooling capacity 178,0 1209,5 Liquid chiller equipped with screw compressors and axial fans. glider Y GENERL FETURES CL (R134a) Cooling capacity 326,0 1328,0 Liquid chiller with -Class Energy Efficiency equipped with screw compressors and axial fans. The units are a complete range including liquid chillers and free-cooling chillers, with high energy efficiency and reduced operating costs, granting an efficacious answer to the today s needs of comfort and Hi-Tech air conditioning as well as in the industrial process cooling. Developed with the most advanced 3D-CD software, chillers are available in two brand new cabinet types (for a more rational internal layout), an extremely innovative condenser fan section and the state of the art of electrical, electronics and refrigerating components. FREE (R134a) Cooling capacity 198,0 1106,0 Free Cooling capacity 279,0 1093,0 Liquid chiller equipped with screw compressors, axial fans and free cooling system. R134a CLSS SHELL C E C FREE COOLING CL CL FREE Cooling Screw type compressor R134a refrigerant charge class energy efficiency Shall and tube type evaporator xial fan with C motor xial with brushless type EC motor Free-Cooling system Outdoor installation gli

3 air cooled liquid chillers and free cooling chillers 101 MIN COMPONENTS Housing in epoxy painted galvanized steel profiles. Screw compressors xial fans with stepless speed control Shell and tube evaporator with one refrigerant circuit for each compressor Electronic expansion valve Free cooling system ( FREE) Pump-Down stop system MP.COM microprocessor control Electrical box in separate compartment -CLSS CL chillers stand out for the high efficiency of the whole series with EER values always superior to 3,1 -Class energy ratio, in agreement with EECCC (Energy Efficiency and Certification of Central ir Conditioning). Main switch with door lock safety glider f MIN OPTIONL CCESSORIES Pumping group Water tank Partial or total heat reclaim Glycol-Free system ( FREE) LNO kit for noise reduction ELN kit for extreme noise reduction Brine and Brine B kit for glycol solution production with temperatures down to -12 C. Serial port FREE COOLING The FREE series is a type of liquid chillers equipped with a built-in additional coil making Free Cooling using the outdoor air as cooling media. The free-cooling system installed on these chillers has been designed and applied by RC GROUP for the first time in the early 70 s and the today s series is the result of this experience. These chillers allow to achieve remarkable energy savings when installed in cold and temperate climate zones. der glider n

4 102 air cooled liquid chiller and free cooling chillers TECHNICL DT ND NOMINL PERFORMNCES V2 N8 V2 N9 V2 N9 V2 Y2 V2 Y3 V2 Y3 V2 Y3 V2 Y3 V2 Y3 178,0 212,0 254,0 303,0 330,0 392,0 416,0 476,0 522,0 62,24 73,61 87,29 102,37 113,40 132,43 141,50 162,46 177, ,9 74,0 74,5 77,0 76,6 78,7 78,7 78,8 78,8 610 (*) 680 (*) 720 (*) 780 (*) 870 (*) 990 (*) 1130 (*) 1210 (*) V2 Y4 V2 Y4 V2 Y5 V2 Y5 V2 Y5 V2 F14 V2 F16 V2 F20 609,6 676,6 714,0 784,9 874,4 987,7 1129,9 1209,5 194,02 214,81 226,30 251,30 278,56 312,17 357,40 387, ,8 80,8 81,7 81,5 81,5 80,5 80,9 81,0 (1) Referred to chilled water temperature 12/7 C and air to the condenser at 35 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms (*) s so marked are not EUROVENT certified POWER SUPPLY: 400/3/50 CL Class energy efficiency Energy Class More efficient + B C D E F G Less efficient V2 Y3 V2 Y4 V2 Y4 V2 Y4 V2 Y4 V2 Y4 326,0 368,0 395,0 424,0 509,0 540,0 102,84 116,83 129,09 140,86 161,08 170, ,5 76,9 78,9 78,9 79,0 79,0 620 (*) 690 (*) 760 (*) 820 (*) 890 (*) 960 (*) 1010 (*) 1170 (*) 1330 (*) V2 Y5 V2 Y5 V2 F12 V2 F14 V2 F14 V2 F16 V3 F16 V2 F20 V2 F20 619,8 692,3 801,5 822,5 886,3 957,4 1020,6 1170,7 1328,0 182,77 204,29 202,79 239,62 259,12 280,78 300,13 340,55 390, ,9 80,9 80,5 80,4 80,5 80,5 80,5 81,0 81,0 (1) Referred to chilled water temperature 12/7 C and air to the condenser at 35 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms (*) s so marked are not EUROVENT certified POWER SUPPLY: 400/3/50

5 air cooled liquid chillers and free cooling chillers 103 TECHNICL DT ND NOMINL PERFORMNCES FREE Free Cooling capacity (2) Sound pressure (3) 200 (*) 220 (*) 250 (*) 270 (*) 310 (*) 350 (*) 410 (*) 420 (*) 450 (*) 510 (*) 560 (*) 190 (*) 230 (*) V1 Y2 V1 Y2 V1 Y2 V1 Y2 V1 Y2 V1 Y3 V1 Y3 V1 Y4 V1 Y4 V1 Y4 V1 Y5 V2 Y2 V2 Y ,36 72,66 81,36 91,46 103,66 121,08 137,08 143,60 153,60 171,60 191,12 64,30 74, ,2 70,2 70,2 70,2 70,2 73,2 73,2 74,9 74,9 74,9 77,4 71,2 71,2 Free Cooling capacity (2) Sound pressure (3) 260 (*) 320 (*) 360 (*) 430 (*) 540 (*) 630 (*) 700 (*) 740 (*) 830 (*) 860 (*) 930 (*) 1000 (*) 1110 (*) V2 Y3 V2 Y4 V2 Y4 V2 Y5 V2 Y5 V2 Y5 V2 Y5 V2 F12 V2 F16 V2 F16 V2 F16 V2 F20 V2 F ,80 109,00 120,00 142,60 174,60 208,60 227,60 246,60 275,80 285,80 307,80 335,00 372, ,2 76,9 78,9 79,4 79,4 79,4 79,4 80,5 80,5 80,5 80,5 81,0 81,0 (1) Referred to chilled water temperature 12/7 C / 20% glycol and air to the condenser at 35 C (2) Referred to water inlet temperature at 15 C / 20% glycol and outdoor temperature at 3 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms (*) s so marked are not EUROVENT certified POWER SUPPLY: 400/3/50

6 104 air cooled liquid chiller and free cooling chillers dimensions (mm) N V2 N c V2 N b a Y V2 Y V2 Y V2 Y V2 Y FREE Y c V1 Y2 / V2 Y V1 Y3 / V2 Y V1 Y4 / V2 Y V1 Y5 / V2 Y a b F V2 F V2 F V2 F V2 F c FREE F V2 F V2 F V2 F a b

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors. Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

MOLLIER DIAGRAM CAN BE IMPROVED!

MOLLIER DIAGRAM CAN BE IMPROVED! MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.

More information

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51 CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP

More information

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE

More information

CTC Low Temperature Process Chillers

CTC Low Temperature Process Chillers INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in

More information

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited

More information

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge

More information

Rack cooling solutions for high density racks management, from 10 to 75 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw Rack cooling solutions for high density racks management, from 10 to 75 Superior efficiency, high reliability, low energy consumption Modern data center are characterized by 24/7 operation all year long.

More information

IT Air Conditioning Units

IT Air Conditioning Units IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack

More information

2018 Product overview

2018 Product overview 2018 Product overview Project conditioning Evolution goes on During these years, the activity of EMICON has been developed with the production of liquid chillers for conditioning and industrial applications,

More information

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS CHAPTER WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS Unit Page CWW/K 8-9 CWW/K 8-P 0-P 0 - CWW/K 8 0 - MEA/K - MEA/K 8-P 0-P - RCA/K

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

Air-Cooled Series R Chiller

Air-Cooled Series R Chiller Air-Cooled Series R Chiller The next generation of Air-Cooled Helical Rotary Chillers ANOTHER RELIABLE SOURCE OF CHILLED WATER FROM TRANE The new industry standard f The next generation of the air-cooled

More information

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough

More information

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S FREE COOLING CHILLER Getting To A PUE Of 1.2 Free cooling data center chillers are designed to

More information

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market

More information

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC: Freecooling Solutions for Increased Data Center Efficiency and PUE of 1.1 Freecooling data center chillers

More information

Werner Finley Private Limited

Werner Finley Private Limited +91-8048719225 Werner Finley Private Limited https://www.indiamart.com/wernerfinley/ We are manufacturer & exporter of precious range of industrial cooling systems & industrial chillers that includes coolant

More information

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices

More information

Reliability and extended operation

Reliability and extended operation CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter

More information

WO P-NF-L-M-407c Spec Submittal

WO P-NF-L-M-407c Spec Submittal WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational

More information

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment Precision Cooling for Business-Critical Continuity Liebert HPC-M The Data Center FreeCooling Chiller with the Lowest Impact on the Environment Emerson Network Power, a division of Emerson Electric Co.,

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

ZTE ZXCR Series DX In-Row Air Conditioning Product Description ZTE ZXCR Series DX In-Row Air Conditioning Product Description Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase

More information

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT DYNACIAT: HIGH PERFORMANCE HEATING AND COOLING FOR MEDIUM-SIZED BUILDINGS To better meet customer needs and answer environmental

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1700 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1700 kw Vertiv Vertiv designs, builds and services mission critical technologies that

More information

HIGH EFFICIENCY Central Chiller

HIGH EFFICIENCY Central Chiller Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HIGH EFFICIENCY Central Chiller Energy Efficient Modular & Expandable Virtually Eliminate Downtime Available in 20-60 ton single units,

More information

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW The indirect evaporative free-cooling Air Handling Unit Flexible & Efficient 11 sizes from 30 kw up to 520 kw to fit your needs with maximum efficiency

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Liebert HPC Freecooling Chiller

Liebert HPC Freecooling Chiller Precision Cooling for Business-Critical Continuity Liebert HPC Freecooling Chiller Data Center Freecooling with 100% Compressor Back Up Whether a Data Center houses three or 1000 IT racks, deployment of

More information

Precision Cooling Mission Critical Air Handling Units

Precision Cooling Mission Critical Air Handling Units M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly

More information

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE. Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE Conformity of the device Vertiv Liebert AFC with the hygiene requirements of the guideline

More information

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency September 27 th, 2013 Tejas Desai, PE CEM CEA LEED AP Sameer Behere, PE CEM LEED AP Agenda Problem: Quick fixes can

More information

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL

VARIABLE REFRIGERANT FLOW SYSTEMS HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL HITACHI SMARTFLEX VRF GEN II FLEXIBILITY, PERFORMANCE AND CONTROL Expanding the possibilities STATE-OF-THE-ART DESIGN TAKES PERFORMANCE TO NEW LEVELS Our re-engineered Outdoor Units boast an extended operating

More information

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class

More information

Chillventa Specialist Forums 2018 Chillventa Fachforen 2018

Chillventa Specialist Forums 2018 Chillventa Fachforen 2018 Hall 9 Chillventa Specialist Forums 2018 Chillventa Fachforen 2018 NürnbergMesse, Arbeitstitel, Datum 1 Liquid to liquid Plate Heat Exchangers certification 17 October 2018 Nuremberg Marie-Clémence BRIFFAUD

More information

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world

More information

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02 pco 3 Controller User Manual Introduction The Airstack Chiller is a modular air-cooled chiller composed of

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution CGWN/CCUN indoor liquid chillers The compact AquaStream² solution Plug and Play for unparalleled Certified performance Eurovent certification provides capacity and efficiency compliance, thus confirming

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

Liebert HPC. Data Center Freecooling Chiller with 100% Compressor Back Up

Liebert HPC. Data Center Freecooling Chiller with 100% Compressor Back Up Liebert HPC Data Center Freecooling Chiller with 100% Compressor Back Up Liebert HPC Freecooling Chiller Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications

More information

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net Digi-RTU WHAT IS THE DIGI-RTU The Digi-RTU is a Heating, Ventilation, and Air Conditioning (HVAC) rooftop unit control kit that is both a demand management and energy usage device. It is designed to improve

More information

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England > For the latest information on our products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information Your nearest Airedale distributor is: ISO 14001 EMS52086

More information

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Engineering Data SED: 8012 Group: Centrifugal Chiller Date: March 2002 Supercedes: New Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Model WSC/WDC 2002 McQuay International

More information

Designing Ultra-Efficient Building Cooling Systems

Designing Ultra-Efficient Building Cooling Systems Designing Ultra-Efficient Building Cooling Systems Design to Apply Effective Optimization Technologies To Chiller Plants and Air Systems ASHRAE Triangle Chapter Raleigh, NC November 16, 2016 Tom Hartman,

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1450 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC, the Ideal Adiabatic Chilled Water Solution for Top-Tier Data Centers Emerson Network Power delivers

More information

DEDICATED HEAT RECOVERY UNIT (DHRC)

DEDICATED HEAT RECOVERY UNIT (DHRC) DEDICATED HEAT RECOVERY UNIT (DHRC) AHRI CERTIFICATION Air-Conditioning, Heating, and Refrigeration Institute Multistack is AHRI Certified and continues to certify products as they are developed AHRI Certification

More information

CONDENSING UNITS UASL- JEC

CONDENSING UNITS UASL- JEC FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

Data Center Energy Savings By the numbers

Data Center Energy Savings By the numbers Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

Performance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot

Performance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot Performance Certification : From Energy Efficiency To Indoor Air Quality By: Eric Foucherot Certified Products for Efficient & Safe Design Certified Performances for HVAC&R Product AIR CONDITIONERS CHILLERS

More information

Trailblazer AGZ-E air-cooled scroll chillers

Trailblazer AGZ-E air-cooled scroll chillers Trailblazer AGZ-E air-cooled scroll chillers 30 to 240 tons with Variable Speed Condenser Fan Technology The right features, the right value, right now Intelligent Equipment AGZ-E 30 to 161 RapidRestore

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

New Design Strategies for Energy Saving. Intelligent free-cooling

New Design Strategies for Energy Saving. Intelligent free-cooling New Design Strategies for Energy Saving Intelligent free-cooling Intelligent New strategies for energy saving When designing mission critical systems for processing applications or highly technological

More information

How To Draw Chiller Monsters Werewolves Vampires And Zombies

How To Draw Chiller Monsters Werewolves Vampires And Zombies How To Draw Chiller Monsters Werewolves Vampires And Zombies We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer,

More information

IT COOLING CHILLERS. AIR COOLED CHILLERS WITH FREE-COOLING TECHNOLOGY, FROM 302 TO 1649 kw

IT COOLING CHILLERS. AIR COOLED CHILLERS WITH FREE-COOLING TECHNOLOGY, FROM 302 TO 1649 kw IT COOLING CHILLERS AIR COOLED CHILLERS WITH FREE-COOLING TECHNOLOGY, FROM 302 TO 1649 kw IT COOLING CHILLERS THE GREATER PART OF PROGRESS IS THE DESIRE TO PROGRESS Lucio Anneo Seneca Latin Philosopher

More information

Overview of cooling solutions.

Overview of cooling solutions. From laser to food and beverage and manufacturing process cooling applications, Glen Dimplex Thermal Solutions (GDTS) offers innovative cooling solutions. Most processes today utilize fluid cooling systems

More information

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01

More information

We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our

We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our clients requirements and with the lowest environmental

More information

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS Capacity from 600 to 2,010kWr Engineered for flexibility and performance PRODUCT LEAFLET THE AWS SERIES OFFERS TOP EFFICIENCY, LOW SOUND LEVELS AND FLEXIBLE

More information

TCC-100 Thermostatted Column Compartment Quick Installation Guide August 2003 Rev. 2 Page Dionex

TCC-100 Thermostatted Column Compartment Quick Installation Guide August 2003 Rev. 2 Page Dionex TCC-100 Thermostatted Column Compartment Quick Installation Guide August 2003 Rev. 2 Page 1 This Quick Installation Guide provides information about how to install the TCC-100 Thermostatted Column Compartment

More information

Communication Register Map - Uniflair Cooling

Communication Register Map - Uniflair Cooling DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R

More information

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners Page 1 of 184 Software for the simulation of refrigeration equipment and air conditioners Index Software for the simulation of refrigeration equipment and air conditioners... 1 : application description

More information

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE 90.1-2016 Revisions to Waterside Economizer March 15, 2017 Stefan Gracik 510-663-2070 sgracik@integralgroup.com Agenda 1. Background

More information

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw i-accurate_gb_07-2011 igh precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 Coming form 40 years experience in air conditioning and

More information

Ceiling Concealed Split System C Series

Ceiling Concealed Split System C Series Brochure AP MCC C 07A Ceiling Concealed Split System C Series features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according

More information

Air-Cooled Chillers. R134a. Performance Matters

Air-Cooled Chillers. R134a. Performance Matters TM Air-Cooled Chillers R134a Performance Matters The end of the air-cooled chiller compromise TM Get the benefits of an air-cooled design, plus energy efficiency and quiet operation When choosing between

More information

Aquaflair. BREC/F and BCEC/F kw

Aquaflair. BREC/F and BCEC/F kw Aquaflair Air-cooled chillers and free-cooling chillers with screw or oil-free centrifugal compressors equipped with adiabatic system BREC/F and BCEC/F 350-1350 kw Dualism for evolution: the combination

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

THE EUROPEAN REFERENCE

THE EUROPEAN REFERENCE THE EUROPEAN REFERENCE Eurovent Certified Performances certification for IT COOLING UNITS Data Centre World 2019 - London Morgane LAJEUNESSE Project Manager m.lajeunesse@eurovent-certification.com Agenda

More information

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011 APC InRow Cooler Prototype Initial Report - Test Setup Verification H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011 1 Introduction Contents Technology Description/Attributes Installation

More information

4. TARGETED COOLING & AIRFLOW MANAGEMENT

4. TARGETED COOLING & AIRFLOW MANAGEMENT 4.4. TARGETED COOLING & TARGETED COOLING & AIRFLOW MANAGEMENT 4.AIRFLOW TARGETED MANAGEMENTCO 76 79 80 81 82 :: targeted cooling & airflow management 4. TARGETED COOLING & AIRFLOW MANAGEMENT 4.1 - Side

More information

Contents. Cabinet Components " Exploded View... 1 " Usage List U.S. Models... 2 " Usage List Canadian Models... 3 " Blank Page...

Contents. Cabinet Components  Exploded View... 1  Usage List U.S. Models... 2  Usage List Canadian Models... 3  Blank Page... Replacement Parts Manual WAG SERIES COMBINATION GAS / ELECTRICS Models: WAG30D WAG36D WAG40D General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual

More information

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get * Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get * Trane CenTraVac chillers: Designed and built to be the best; tested to prove it Ongoing innovation. Unmatched capabilities.

More information

Ecoflair Air Economizers

Ecoflair Air Economizers Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information