Large Frame IEC Contactors
|
|
- Patrick Long
- 5 years ago
- Views:
Transcription
1 Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1
2 Changing Applications for Contactors There are fewer and fewer traditional large motor starting applications Migration to newer technologies (drives, soft starters) PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 2
3 Changing Applications for Contactors More applications are emerging in isolation, bypass & alternate energy PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 3
4 100-E Overview New 100-E Contactors Smaller Size and Footprint Reduces panel space and shipping costs Wide Range AC/DC Electronic Coils Enables ease of design and selection Eco-friendly design reduces power requirements 25-65% Reduces the size of the power supply or control transformer Safety Solutions A Mirror contactor performance SUVA third-party certified PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 4
5 100-E Overview New 100-E Contactors Expanded Accessories Worldwide Accepted Approvals Global approvals for all industries Expanded ratings Current ratings up to 2650A 1000V ratings for all sizes UL DC ratings These new contactors enable our customers to efficiently design and build smaller panels, reducing energy consumption, offering global certifications. PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 5
6 100-E Contactor Range Rating Width in mm 90 mm 105 mm 140 mm 100- E116 E146 E190 E205 E265 E305 E370 AC-1 (A) V V PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 6
7 100-E Contactor Range Width in mm 186 mm 210 mm 438 mm 100- E400 E460 E580 E750 E1260 E860 E1060 E2050 E2650 Rating AC-1 (A) PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 7
8 IEC 100-E Panel Presence 100D 100E D115/140 E116/146 D180 E190 D210 E205 D250/300 E265/305/ D630/ E580/750 E400/ D % narrower width 50% lower weight PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 8
9 Electronic Coils Wide Range AC/DC Electronic Coils 4 coils cover V AC/DC Enables ease of design and selection Eco-friendly design reduces power requirements 25-65% Less heat generation Reduces the size of the power supply or control transformer Lowers inventory requirements Built-in surge suppression Allows for a PLC input Quiet operation PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 9
10 Lower AC Power Consumption Pick-Up Hold-In Contactor 100-E V 50 60Hz 100-D Electronic 50 Hz, 60 Hz, 50/60 Hz 100-E V 50 60Hz 100-D Electronic 50 Hz, 60 Hz, 50/60 Hz 116A/146A [VA] A/205A [VA] A/305A/370A [VA] A/460A [VA] A/750A [VA] A/1060A [VA] A [VA] A/2650A [VA] % lower inrush, 46-54% lower sealed through 205A PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 10
11 Lower DC Power Consumption Pick-Up Hold-In Contactor 100-E 20 60V DC 24 60V DC 100-D Electronic DC 100-E 20 60V DC 24 60V DC 100-D Electronic DC 116A/146A [W] A/205A [W] /540* A/305A/370A [W] A/460A [W] A/750A/1260A [W] * Inrush requirements may be up 540W for less than 10 ms 26-62% lower inrush, 42-58% lower sealed through 370A PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 11
12 Safety Solutions 100S Safety Contactors 116A 580A AC/DC Operating Coils Built-in Surge Suppression Mirror contact performance per IEC , Annex F Red Low Power N.C. Auxiliary contact used for feedback circuit SUVA third-party Certification PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 12
13 Accessories Auxiliary contacts 1 NO 1 NC (inside or outside mounting) 1 NO or 1 NC (sealed micro switch) Mechanical interlocks Terminal lugs Terminal shrouds For use with terminal lugs For use with crimp connectors Connection bars for 140G circuit breakers PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 13
14 Accessories Connection bars for reversing contactors or starters Connection bars for star-delta starters Terminal enlargements Terminal extensions Mounting plates Coils Contact kits Arc chutes PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 14
15 Overload Solutions Overload Relays Direct mount E1 Plus 100-E116 E146 (30-150A) 100-E190 E205 (40-200A) Direct mount E E116 E146 (20-200A) 100-E190 E205 (20-200A) Current Transformer Solutions Separate CT kits and panel mounted overload relays 300:5 and 600:5 CT s for UL solutions 300:5 and 400:5 CT s for IEC solutions PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 15
16 Certifications In Process PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 16
17 Expanded Ratings Ampere ratings up to 2650A 1000V Ratings AC-1, AC-3, AC-4 UL DC General-Purpose Ratings for alternate energy UL/CSA Definite Purpose Ratings for HVAC applications CSA/ASME Elevator Duty Ratings UL/CSA Ballast Lighting Ratings PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 17
18 Bulletin 300 Space Saving Contactors Completes the Product Offering Competitive offering versus Eaton, Schneider and Siemens Previous offering limited up to Size 5 Contactors and Size 2 Starters Now Size 0 through 8 Contactors and Reversing Contactors Assembled Starters through Size 4; CT based starters through Size 8 Overload options of E1+ or E300 PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 18
19 PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 19
Allen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More informationXT IEC Power Control Contactors, Starters and Overload Relays
May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More information3RA13, 3RA14 Contactor Assemblies
RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock
More informationAllen-Bradley Drives
Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationSeries CA9 Contactors
Series C9 Contactors Sprecher + Schuh s C9 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this wide horsepower range. C9 contactors offer a
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationStarters. Power. Manual Motor Low Voltage Starters 600, 609, 609U, 609TU. 600 Manual Starting Switches 609 Manual Starting Switches
Starters Manual Motor Low Voltage Starters 600, 609, 609U, 609TU Compact design Undervoltage protection Manual operation with overload protection Ideal for low HP applications, up to 10 HP three phase
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationTable 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.
IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More informationContactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationSeries CA7 Contactors
C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor
More informationExercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION
Exercise 1-4 Contactors and Control Relays EXERCISE OBJECTIVE Identify the characteristics of control relays and contactors. DISCUSSION OUTLINE The Discussion of this exercise covers the following points:
More informationSimply on. Simply off. Day and Night. sirius SWITCHING
Simply on. Simply off. Day and Night. sirius SWITCHING SIRIUS-Funktionen im Überblick Switching Protecting Starting Monitoring and controlling Detecting Commanding and signaling Supplying Engineering SIRIUS
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Complementary Assembly style Function available Power supply voltage limits Main Commercial Status Commercialised
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationC 2 5 D N A A A
Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,
More informationNF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)
More informationCI-tronic Soft start motor controller
MAKING MODERN LIVING POSSIBLE CI-tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Technical brochure Contents Page Soft start motor controller, MCI 3, MCI
More informationContacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay
Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationBulletin 700-P, 700DC-P Industrial Relays
Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700 P Direct Drive Convertible Contact Cartridge Relays NEMA and IEC ratings 600V maximum AC/DC Accessories for field installation: contact cartridges,
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationMOTOR CONTROL. Mini-Contactors and Thermal Overload Relays. SK Series 62C1-E-0022
MOTOR CONTROL Mini-Contactors and Thermal Overload Relays 62C1-E-0022 and Thermal Overload Relays : SK06, SK09, and SK12 The Smallest Class of Magnetic Contactors and Thermal Overload Relays in the World
More information3 Pole Contactors with AC operating coils
1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to
More informationExperiment #2 PLC Input Output Wiring Methods. OBJECTIVES After successfully completing this laboratory, you should be able to:
Experiment #2 PLC Input Output Wiring Methods OBJECTIVES After successfully completing this laboratory, you should be able to: Read and explain the nameplate of DELTA s PLC DVP Series Model. Make different
More informationpointofsale available at your local trade outlet
pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 0 South nd Street Milwaukee, WI 504 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationCert.Record No _C_000, Class No , DQD No 548 Rev
Page 1 of 7 CERTIFICATION RECORD The company named below has been authorized by CSA International to represent the products listed in this record as CSA Certified and to affix the CSA Mark to these products
More informationTSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W
Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold
More informationK-Line Mini - Contactors, Overload Relays and Accessories
K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................
More informationIEC Contactor Specifications
Technical Data IEC Contactor Specifications Bulletin Numbers 00/0-K, 00/0-C, 00/0S-C, 00/0-D, 00S-D, 00-G, 00Q-C Topic Page Product Line Overview 00-K/0-K Miniature Contactors Coil Voltage Codes Assignment
More informationControl, Timing + Ice Cube Relays
... 2 Technical Information... 14 CS8... 18 Technical Information... 21 RZ7-FS Electronic... 24 Technical Information... 34 RZ7-FE Electronic... 36 Technical Information... 42 Relpol Ice Cube Relays R2/R4
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationSIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED
SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment
More informationApplikationen & Tools. Safe switching of IO-Link motor starter combination 3RA27 with safety relay 3SK1. IO-Link. FAQ November 2012
Deckblatt Safe switching of IO-Link motor starter combination 3RA27 with safety relay 3SK1 IO-Link FAQ 66004980 November 2012 Applikationen & Tools Answers for industry. Industry Automation und Drives
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationIndustrial Controls. Protection Devices. Gerätehandbuch. Answers for industry. Edition 09/2014
Industrial Controls Protection Devices SIRIUS Innovations - Thermal Overload Relays SIRIUS 3RU2 / Solid-State Overload Relays SIRIUS 3RB3 Gerätehandbuch Manual Edition 09/2014 Answers for industry. SIRIUS
More informationNC2 Contactor, 115~630A. 1. General. 2. Type Designation. 3. Terminal Connection. Cabling(Cu) Cable 2. Tightening torque (N m) Screw size
R C US LISTED EU Germany Czech Ukrain South Africa USA NC Contactor, 5~30A. General. Certificates: CE, VDE, ESC, UKRTEST, RCC, UL.. Electric ratings; AC50/0Hz, up to 000V, up to 30A;.3 Application: remote
More informationClick 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.
Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationThe PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC
The PCI Series Phase Angle Fired SCR Power Controls 25-1200 AMPS 120-600 VAC Precise power control for complex SCR applications. ROBICON 1996 Distributed Worldwide by www.mcgoff-bethune.com Applications
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationFor Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.
For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationTable of Specifications
Table of Specifications Midi-Contactors 3-Pole Magnetic Contactors Terminal type CC9 CC12 CC18 CC22 CC32 CC40 Screw Only Screw Only GUA1, GUA2, GUA4 GUA-1 GUA-2, GUA-4 GUA-1 GUA-2, GUA-4 GT Type Thermal
More informationTeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters
Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationonlinecomponents.com
ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationInnovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction
Eckard Eberle, Head of the Control Components Business Segment Siemens AG, Nuremberg International Trade Press Conference held on 24 November 2009 in Nuremberg Innovations in the Sirius Modular System
More informationRUC industrial relays of small dimensions
RUC industrial relays of small dimensions 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationAllen-Bradley 700-K40E-DJ
Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationCP30F Series Circuit Protector for Improving Safety and Wiring Workability
CP30F Series Circuit Protector for Improving Safety and Wiring Workability EMURA, Takeshi * A B S T R A C T A circuit protector is a circuit-breaker that possesses both overcurrent protection and switch
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationThe Center of Automation with IEC Products. CENTERLINE Motor Control Center. Allen-Bradley Replacements
The Center of Automation with IEC Products CENTERLINE Motor Control Center Allen-Bradley Replacements 2 Continually enhanced since its introduction in 1971, CENTERLINE is the leading MCC in the North American
More informationMOTUS ContactronControl. Less is more.
MOTUS ContactronControl. Less is more. Content. MOTUS Less is more. Less wear, longer lifespan. Learn more about MOTUS at our website. 3 Our Company. Page 4. For more than 80 years, Wöhner has stood for
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationG3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend
Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures
More information