Tintri Deployment and Best Practices Guide for VMware vcenter Site Recovery Manager

Size: px
Start display at page:

Download "Tintri Deployment and Best Practices Guide for VMware vcenter Site Recovery Manager"

Transcription

1 TECHNICAL WHITE PAPER Tintri Deployment and Best Practices Guide for VMware vcenter Site Recovery Manager v1.1 May

2 Revision History Version Date Description Author /01/2017 Document title changed Formatting updates SRM versioning updates Miscellaneous clarifications /01/2014 Previously known as Tintri Deployment and Best Practices Guide for VMware vcenter Site Recovery Manager 5.8 Table 1 - Revision history Tintri Technical Marketing Previous contributors 2

3 Contents Revision History... 1 Intended Audience... 5 Consolidated List of Practices... 5 Executive Summary... 6 Assumptions... 6 VMware vcenter Site Recovery Manager with Tintri VMstore Overview... 6 Prerequisites... 7 Licensing... 7 vsphere... 7 vcenter Server... 7 Site Recovery Manager... 8 Tintri VMstore... 9 Site Recovery Manager System Requirements... 9 Site Recovery Manager Network Ports... 9 Operational Limits of Site Recovery Manager...10 Requirements for Using Microsoft SQL Server with Site Recovery Manager (optional)...10 Requirements for Using Oracle Server with Site Recovery Manager (optional) Requirements for Tintri VMstore Configuration Create an ODBC System DSN for SRM in the host you chose for the SRM Server Prerequisites Procedure Site Recovery Manager Server Installation Pre-installation Checklist Install Site Recovery Manager Server Install Tintri SRA Connect the Site Recovery Manager Server Instances on the Protected and Recovery Sites Install the Site Recovery Manager License Key Configure Inventory Mappings Create resource mappings Create folder mappings Create network mappings Configure Placeholder Datastore Configure the Tintri VMstores

4 VMstore in the Recovery Site Add Array Manager and Enable Array Pair Create a Protection Group Create Recovery Plan Testing Test Recovery Plan Running a Recovery Plan Reprotect Conclusion References Tintri VMware Microsoft

5 Intended Audience This Best Practices Guide for running VMware vcenter Site Recovery Manager (SRM) on Tintri VMstore systems is intended to assist Data Protection and Disaster Recovery Administrators, IT Administrators and Architects who are responsible for deploying and managing a Disaster Recovery (DR) strategy within their virtual infrastructures powered by Tintri VMstore storage appliances. This guide focuses specifically on SRM 5.8 and therefore all instructions and screenshots focus on the vsphere Web Client although the Tintri Storage Replication Adapter (SRA) supports version SRM 5.5 as well as newer SRM versions (6.0, 6.1, and 6.5). The fundamental SRM operations and VMstore support are identical in all of these versions; this guide happens to focus on SRM 5.8, but the concepts apply to all SRM versions. If you are not already versed in VMware SRM, we recommend you follow the content within this guide to create one or more SRM Recovery Plans in a test environment to gain familiarity with the technologies prior to deploying and configuring SRM a production deployment for use with Tintri VMstore systems. Consolidated List of Practices The list below includes the recommended practices in this document. Click the text on any of the recommendations to jump to the section that corresponds to each recommendation for additional information. DO: Install the same version of Site Recovery Manager Server and vcenter Server on both sites (protected and recovery). DON T: explicitly configure VMstore replication for VM's intended for use with SRM. Creating the VMstore Service Group (below) will indirectly configure VM replication. DO: Make sure you have a ReplicateVM license for your Tintri VMstores. DO: We recommend trying VM-consistent first in a test environment, with copies of the production applications and testing if the impact is acceptable or not. DO: Create a Service Group for each SRM Array Manager Pair i.e. pair between Protected and Recovery VMstores that you plan on creating in SRM. There is a 1:1 mapping between Tintri Service Groups and SRM Array Manager Pairs. DON T: Try and Add a pair of array managers before you create the corresponding Service Group in the Primary s VMstore. The array manager pair creation in SRM will fail if there isn t a corresponding Service Group already created via the Tintri GUI. DON T Run a Recovery Plan for testing; use the Test Recovery Plan feature for testing. 5

6 Executive Summary VMware vcenter Site Recovery Manager is disaster recovery solution that provides automated orchestration and non-disruptive testing of centralized recovery plans for all virtualized applications - see more at: Site Recovery Manager 5.8 brings additional enhancements for managing DR workflows. The most visible change is that SRM 5.8 is fully integrated as a plug-in with the vsphere Web Client. In addition to not having to use two different interfaces to manage virtual environments, improvements were also made to a few workflows making it easier and simpler to map arrays, networks, folders, etc. by having SRM handle the reciprocal instead of having to do it manually. This guide will walk you through the process of setting up VMware vcenter Site Recovery Manager 5.8 on Tintri VMstore 3.1 and provide best practice guidelines to implement a Disaster Recovery solution that is as unobtrusive as possible in day to day (normal) operations, but still provides you with the RPO (Recovery Point Objective) and RTO (Recovery Time Objective) you need for your business. Assumptions This document assumes you are working with a fully configured virtual infrastructure. It also assumes that, in case you are leveraging Microsoft Active Directory (AD) for authentication and policy management and enforcement, that there already is a non-srm-based AD disaster recovery plan in place (e.g. leveraging AD Native Replication) as per Microsoft Best Practices. AD should not be replicated using storage replication technology, as it could potentially cause a USN rollback scenario. Refer to the Microsoft articles listed on page 40 for more information on this. VMware vcenter Site Recovery Manager with Tintri VMstore Overview Legacy disaster recovery strategies that depend on manual procedures and complex run books to execute require highly specialized staff, large investments and complex coordination from several teams responsible for different layers of the data center infrastructure. VMware Site Recovery Manager, combined with Tintri VMstore, shields users from having to manage many of the steps required for traditional recovery. Tintri ReplicateVM provides the ability to configure replication at the virtual machine level. Setting up a recovery plan can be done in a matter of minutes, instead of weeks. Ongoing disaster recovery provisioning to new virtual machines can be driven through predefined policies. Actual execution of testing, recovery and migration workflows is fully automated to eliminate operational complexity. Tintri ReplicateVM provides extremely WAN-efficient array based replication between Tintri VMstores. Tintri s Storage Replication Adapter (SRA) leverages the easy management and WAN-efficient replication capabilities of Tintri OS to provide SRM integrated DR workflows, resulting in an extraordinarily simple and quick setup, followed by minimal replication traffic between VMstores, saving bandwidth and time and therefore lowering TCO. The performance impact on each VMstore is also minimal, ultimately resulting in enabling an unobtrusive DR strategy with incredibly low TCO. 6

7 Figure 1 SRM with Array-Based Replication (ABR) Prerequisites Licensing vsphere Site Recovery Manager is supported with any edition of vsphere, except for vsphere Essentials. vsphere licenses are required for all servers on which vsphere is installed, whether that host is at a protected site or a recovery site and whether a server is running or powered down at the recovery site. Site Recovery Manager requires at least one licensed vsphere server at both the protected site and the recovery site. vcenter Server Site Recovery Manager is supported with vcenter Server for Essentials, vcenter Server Foundation and vcenter Server Standard. 7

8 Site Recovery Manager requires two active and licensed vcenter Server instances, one at each site (protected and recovery). NOTE: The shared recovery sites feature in Site Recovery Manager enables multiple protected sites with multiple vcenter Server instances to be recovered at a site with a single vcenter Server instance. (i.e., the multiple instances of Site Recovery Manager running at the shared recovery site are registered with the same single instance of vcenter Server at the shared recovery site, so you do not need multiple vcenter Server instances at the shared recovery site.). Site Recovery Manager The latest version of Site Recovery Manager can be purchased either as a standalone product or as part of VMware vcloud Suite Enterprise Edition. As a standalone product, Site Recovery Manager is available in two editions, Standard and Enterprise, which can only be purchased on per virtual machine licensing model. Site Recovery Manager Enterprise edition can also be purchased as part of vcloud Suite Enterprise edition. In this case, Site Recovery Manager is purchased on a per processor licensing model. Site Recovery Manager Enterprise provides enterprise-level protection to all virtualized applications with no licensing restriction on the number of virtual machines that can be protected. Site Recovery Manager Standard is designed for smaller environments and is limited to 75 protected virtual machines per physical site and per Site Recovery Manager instance. Only virtual machines that are protected by Site Recovery Manager require Site Recovery Manager licensing. There are two scenarios to consider: Uni-directional protection: Site Recovery Manager is configured only to fail over virtual machines from site A to the site B. In this case, licenses are required only for the protected virtual machines at protected site A. Bi-directional protection: Site Recovery Manager is configured to fail over virtual machines from site A to site B at the same time that it is configured to fail over a different set of virtual machines from site B to site A. In this case, Site Recovery Manager licenses must be purchased for the protected virtual machines at both sites. Licenses are required for all protected virtual machines, even if they are powered off. To fail back from site B to site A (after failover from site A to site B), Site Recovery Manager licenses are required for the re-protected virtual machines at Site B. The per virtual machine licenses originally used at site A can be used at site B for this purpose, as long as the licenses are no longer in use at site A. If Site Recovery Manager is being licensed per processor through the vcloud Suite Enterprise at site A and virtual machines are failed over to a site B that originally licensed with vsphere only, the vcloud Suite licenses can be transferred to site B in order to re-protect and fail back the virtual machines. Refer to VMware vcenter SRM 5.8 FAQ for more information. You must install a Site Recovery Manager Server instance at the protected site and also at the recovery site. SRM Server can run on the same Windows host operating systems as vcenter Server that, as of SRM Server 5.8 and vcenter Server 5.5 U2, includes Windows Server 2008, Windows Server 2008 R2, Windows Server 2012 and Windows Server 2012 R2. You must install the same version of Site Recovery Manager Server and vcenter Server on both sites. You cannot mix Site Recovery Manager or vcenter Server versions across sites. 8

9 DO: Install the same version of Site Recovery Manager Server and vcenter Server on both sites (protected and recovery). For environments with a small number of virtual machines, you can run Site Recovery Manager Server and vcenter Server on the same system. For environments that approach the maximum limits of Site Recovery Manager (as per and vcenter Server, install Site Recovery Manager Server on a system that is different from the system on which vcenter Server is installed. If Site Recovery Manager Server and vcenter Server are installed on the same system, administrative tasks might become more difficult to perform in large environments. If you are using the vcenter Appliance, you will need to install your SRM Servers in a different system than vcenter. Therefore, at a minimum you will need two Windows 2008/2012 server licenses (one for each site, each running SRM Server and potentially vcenter if no appliance is being used and the environment is small enough), but you may need as many as six if you install vcenter, SRM and SQL in separate servers in each site. Tintri VMstore SRM support is included with the ReplicateVM license. VMstore systems deployed at both the protected site and at the recovery site must be licensed for ReplicateVM. Site Recovery Manager System Requirements The system on which you install vcenter Site Recovery Manager must meet specific (virtual) hardware requirements. Site Recovery Manager System Requirements C o m p o n e n t Processor Memory Disk Storage Networking R e q u i r e m e n t 2.0GHz or higher Intel or AMD x86 processor 2 GB minimum. You might require more memory if you use the embedded database, as the content of the database grows. 5 GB minimum. If you install Site Recovery Manager on a different drive than the C: drive, the Site Recovery Manager installer still requires at least 1 GB of free space on the C: drive. This space is required for extracting and caching the installation package. You might require more disk storage if you use the embedded database, as the content of the database grows. 1 Gigabit recommended for communication between Site Recovery Manager sites. Use a trusted network for the management of ESXi hosts. For information about supported platforms and databases, see the Compatibility Matrixes for vcenter Site Recovery Manager 5.8 at Compatibility Matrixes for vcenter Site Recovery Manager 5.8. Site Recovery Manager Network Ports Site Recovery Manager Server instances use several network ports to communicate with each other, with client plug-ins, and with vcenter Server. If any of these ports are in use by other applications or are blocked on your network, you must reconfigure Site Recovery Manager to use different ports. 9

10 Site Recovery Manager uses default network ports for intra-site communication between hosts at a single site and inter-site communication between hosts at the protected and recovery sites. You can change these defaults when you install Site Recovery Manager. Beyond these standard ports, you must also (continue to) meet the VMstore s network requirements. You can change the network ports from the defaults when you first install Site Recovery Manager. You cannot change the network ports after you have installed Site Recovery Manager. For a list of all the ports that must be open for Site Recovery Manager, see For a refresher on the list of all the ports that must be open for the Tintri VMstore, please consult the Tintri VMstore System Administration Manual. For the list of default ports that all VMware products use, see Operational Limits of Site Recovery Manager Each Site Recovery Manager server can support a certain number of protected virtual machines, protection groups, datastore groups, recovery plans, and concurrent recoveries. For details about the operational limits of Site Recovery Manager 5.8 see Requirements for Using Microsoft SQL Server with Site Recovery Manager (optional) Optionally, the Microsoft SQL Server (2005/2008/2012/2014) database can be used instead of the builtin PostgreSQL database. There is no specific reason not to use the built-in Postgres database. If you create a Microsoft SQL Server database, you must configure it correctly to support Site Recovery Manager. This section provides the requirements for a SQL Server database for use with Site Recovery Manager. Consult the SQL Server documentation for specific instructions on creating a SQL Server databases. Database user account: o If you use Integrated Windows Authentication to connect to SQL Server and SQL Server runs on the same machine as Site Recovery Manager Server, use the local service account (that has administrative privileges on the Site Recovery Manager Server machine). Use the same account when you install Site Recovery Manager Server. When the Site Recovery Manager installer detects an SQL Server data source name (DSN) that uses Integrated Windows Authentication, it configures Site Recovery Manager Server to run under the same account as you use for the installer, to guarantee that Site Recovery Manager can connect to the database. o If you use Integrated Windows Authentication to connect to SQL Server and SQL Server runs on a different machine from Site Recovery Manager Server, use a domain account with administrative privileges on the Site Recovery Manager Server machine. Use the same account or an account with the same privileges when you install Site Recovery Manager Server. When the Site Recovery Manager installer detects an SQL Server data source name (DSN) that uses Integrated Windows Authentication, it configures Site 10

11 Recovery Manager Server to run under the same account as you use for the installer, to guarantee that Site Recovery Manager can connect to the database. NOTE: this doesn't always work flawlessly due to problems in the SRM Installer. If it fails, it will do so late in the install with a "retry / fail and back out" error message. If it does so, you can work around the issue by going to the SRM service configuration, change it to be the correct user (it will incorrectly have set it to local service), and then start the service and hit retry. It will then succeed. o If you use SQL authentication, you can run the Site Recovery Manager service under the Windows Local System account, even if SQL Server is running on a different machine to Site Recovery Manager Server. The Site Recovery Manager installer configures the Site Recovery Manager service to run under the Windows Local System account by default. o Make sure that the Site Recovery Manager database user account has the ADMINISTER BULK OPERATIONS, CONNECT, and CREATE TABLE permissions. Database schema: o The Site Recovery Manager database schema must have the same name as the database user account. o The Site Recovery Manager database user must be the owner of the Site Recovery Manager database schema. o The Site Recovery Manager database schema must be the default schema for the Site Recovery Manager database user. The Site Recovery Manager database must be the default database for all SQL connections that Site Recovery Manager makes. You can set the default database either in the user account configuration in SQL Server or in the DSN. Map the database user account to the database login. Requirements for Using Oracle Server with Site Recovery Manager (optional) SRM can also support Oracle Server instead of Microsoft SQL Server. Specifically, Oracle 11g Release 2 and 12C are supported. Note however that we did not test Oracle during the writing of this Best Practices Guide (we tested SQL Server). When you create an Oracle Server database, you must configure it correctly to support Site Recovery Manager. You create and configure an Oracle Server database for Site Recovery Manager by using the tools that Oracle Server provides. This information provides the general steps that you must perform to configure an Oracle Server database for Site Recovery Manager. For instructions about how to perform the relevant steps, see the Oracle documentation. When creating the database instance, specify UTF-8 encoding. Grant the Site Recovery Manager database user account the connect, resource, create session privileges and permissions. Requirements for Tintri VMstore For a typical VMware SRM + Tintri VMstore deployment, you will need two Tintri VMstores one in the Protected Site and the other in the Recovery site. The requirements for these VMstores are: 11

12 - Both VMstores must to be running Tintri OS 3.1 or later - Each VMstore needs to have a ReplicateVM license installed - Each VMstore needs to have their respective/local (Protected or Recovery) vcenter Server configured as a Hypervisor manager (in Settings Hypervisor managers). Configuration This section provides information on configuring VMware SRM and the Tintri VMstore. It is assumed that you ve met the prerequisites from the previous section, including: 1. Have vsphere servers in both sites with the necessary licenses. 2. Have fully configured vcenter Servers in both sites managing all applicable vsphere servers, with the necessary licenses (OS and application). a. The 5.8 release of Site Recovery Manager requires the vsphere Web Client. For information about compatibility between vcenter Server and Site Recovery Manager versions, see vcenter Server Requirements in the Compatibility Matrixes for vcenter Site Recovery Manager 5.8 at 3. Each site can access any necessary Active Directory servers, not protected by SRM even in case one of the sites goes down in case of disaster (e.g. by leveraging AD Native Replication). 4. Have the necessary SRM licenses (permanent or evaluation) and Tintri ReplicateVM licenses. Create an ODBC System DSN for SRM in the host you chose for the SRM Server You must provide Site Recovery Manager with a system database source name (DSN) for a 64-bit open database connectivity (ODBC) connector in the Windows host you chose to install SRM Server on. The ODBC connector allows Site Recovery Manager to connect to the Site Recovery Manager database. You can create the ODBC system DSN before you run the Site Recovery Manager installer by running Odbcad32.exe, the 64-bit Windows ODBC Administrator tool. Alternatively, you can create an ODBC system DSN by running the Windows ODBC Administrator tool during the Site Recovery Manager installation process. N o t e : If you use the embedded Site Recovery Manager database, the Site Recovery Manager installer creates the ODBC system DSN according to the information that you provide during installation. If you uninstall the embedded database, the uninstaller does not remove the DSN for the embedded database. The DSN remains available for use with a future reinstallation of the embedded database. Prerequisites You created the database instance to connect from Site Recovery Manager. Procedure 1. Double-click the Odbcad32.exe file at C:\Windows\System32 to open the 64-bit ODBC Administrator tool. 12

13 I m p o r t a n t Do not confuse the 64-bit Windows ODBC Administrator tool with the 32-bit ODBC Administrator tool located in C:\Windows\SysWoW64. Do not use the 32-bit ODBC Administrator tool. 2. Click the System DSN tab and click Add. 3. Select the appropriate ODBC driver for your database software and click Finish. o SQL Server: Select SQL Server Native Client 10.0, SQL Server Native Client 11.0, or ODBC Driver 11 for SQL Server. NOTE: You may need to install the SQL Server Native Client from the SQL Server distribution ISO in case it s not already installed in the Windows Host. o Create an SQL Server data source for the database. Oracle Server: Select Microsoft ODBC for Oracle. Create an Oracle Server data source for the database. 4. Click Test Data Source to test the connection and click OK if the test succeeds. If the test does not succeed, check the configuration information and try again. 5. Click OK to exit the Windows ODBC Administrator tool. The ODBC driver for your database is ready to use. Site Recovery Manager Server Installation Pre-installation Checklist Download the Site Recovery Manager installation file to a folder on the machine on which to install Site Recovery Manager. Verify that no reboot is pending on the Windows machine on which to install Site Recovery Manager Server. Verify that no other installation is running, including the silent installation of Windows updates. Pending reboots or running installations can cause the installation of Site Recovery Manager Server or the embedded Site Recovery Manager database to fail. The user account that you use to install and run Site Recovery Manager must be a member of the local Administrators group. You can configure the Site Recovery Manager service to run under a specified user account. This account can be a local user or a domain user that is a member of the Administrators group on the machine on which you are installing Site Recovery Manager. If you are using certificate-based authentication, you must obtain appropriate certificate file. You must use the same type of authentication on both sites. See Site Recovery Manager Authentication and Requirements When Using Trusted SSL Certificates with Site Recovery Manager. If you are using certificate-based authentication, provide the certificate for the remote site to the vsphere Web Client service on each site. 13

14 Verify that you have the following information: o The fully qualified domain name (FQDN) or IP address of the site s vcenter Server instance. The server must be running and accessible during Site Recovery Manager installation. You must use the address format that you use to connect Site Recovery Manager to vcenter Server when you later pair the Site Recovery Manager sites. Using FQDNs is preferred, but if that is not universally possible, use IP addresses for all cases. o The user name and password of the vcenter Server administrator account. o A user name and password for the Site Recovery Manager database, if you are not using the embedded database. If you use an SQL Server database with Integrated Windows Authentication as the Site Recovery Manager database, you must use the same user account or an account with the same privileges when you install Site Recovery Manager Server as you used when you created the Integrated Windows Authentication data source name (DSN) for SQL Server. Install Site Recovery Manager Server The steps to Install SRM Server are outlined here: CA8CB680A.html Install Tintri SRA After installing each SRM Server (in each site), you will need to also install the Tintri SRA in each site. The Tintri SRA for VMware SRM can be downloaded from The installation instructions for the SRA are also available from the same site, in the corresponding release notes. Connect the Site Recovery Manager Server Instances on the Protected and Recovery Sites Before you can use Site Recovery Manager, you must connect the Site Recovery Manager Server instances on the protected and recovery sites. The sites must authenticate with each other. This is known as site pairing. Steps are outlined here: BDD0-49B35D html 14

15 After that is completed, this is what you should see in the vsphere Web Client: Figure 2 - Summary tab after SRM Site Pairing Install the Site Recovery Manager License Key Site Recovery Manager Server requires a license key to operate. Install a Site Recovery Manager license key as soon as possible after you install Site Recovery Manager. Follow the steps outlined in A38A-D0342CCC21CA.html Configure Inventory Mappings The next step is to Configure Inventory Mappings. You must create inventory mappings so that Site Recovery Manager can create placeholder virtual machines. Inventory mappings provide a convenient way to specify how Site Recovery Manager maps virtual machine resources at the protected site to resources at the recovery site. Site Recovery Manager applies these mappings to all members of a protection group when you create the group. You can reapply mappings whenever necessary, for example when you add new members to a group. 15

16 This is done in 3 steps: Create resource mappings, Create folder mappings and Create network mappings. Each step can be accessed by clicking the respective link in the Guide to Configuring SRM as shown in Figure 2 and Figure 3 (accessible by going to Site Recovery Sites <Protected Site> Summary in the vsphere Web Client). Figure 3 - Accessing the Configure inventory mappings Wizard 16

17 Create resource mappings Figure 4 - Creating the Resource Mapping In this step, you simply select the resources (e.g. a vsphere server) you want to map in the Protected Site (in the left pane), and then the equivalent resource in the Recovery site (e.g. a different vsphere server, located in the Recovery site). Create folder mappings Figure 5 - Creating the Folder Mapping 17

18 Create network mappings This step allows you to map the virtual networks in the Protected Site to their equivalents in the Recovery Site. Figure 6 - Creating the Network Mapping Configure Placeholder Datastore The next step is to set Placeholder Datastores for each site. Note that these Datastores do not need to be shared or replicated. They are used to keep the.vmx files (not the.vmdk files) on the site that is inactive (Recovery site when everything is OK, Protected site after a failure). Configure the Tintri VMstores Now it s time to for the configuration steps that involve the pair of VMstores you are going to be using. DON T: explicitly configure VMstore replication for VM's intended for use with SRM. Creating the VMstore Service Group (below) will indirectly configure VM replication. 1. Each VMstore needs to be configured and mounted in each respective vsphere/vcenter as a datastore one datastore for each group of VMs to be protected (there will be a mapping between SRM Protection Groups and datastores/mount points on the VMstores. o For SRM, you cannot use the VMstore s default /tintri folder. You will need to create folders under /tintri (e.g. /tintri/srm-protect-base) and mount those as additional datastores. 18

19 Create one folder for each Protection Group you intend to create Use the datastore browser or a standard NFS client to create the extra folders. Mount each folder as a different datastore in the vsphere server: Move the VMs you want to protect into the respective datastore (again each datastore will mean a specific SRM Protection Group). 2. Go to the web GUI of the Tintri VMstore at the Protected site and create a Replication Path to the VMstore in the Recovery site by going to Settings Replication: DO: Make sure you have a ReplicateVM license for your Tintri VMstores. If the Replication option is not visible in your Tintri GUI, it is likely that you don t have a ReplicateVM license installed. If that is the case, please obtain a ReplicateVM license from Tintri, and follow the steps under the Configuring Licenses section of the Tintri VMstore System Administration Manual. 19

20 Don t forget to click Test Paths before you click Save: 3. Also in the Tintri GUI, create a Service group by going to Virtual Machines Service Groups: Give it a name and select which datastore / mount point you want to protect / replicate. NOTE: If the datastore / mount point you just created and moved VMs to doesn t show up in the drop down, that means the VMstore hasn t seen it yet; it can take up to 10 minutes for it to show up. 20

21 Select the right replication path: You can leave the destination folder as the default ( srm ) or change it if you intend to have multiple service groups go into the same VMstore. NOTE: You do not need to create the destination folder yourself; it will be created for you automatically. Furthermore, even if the folder already exists, VMstore will also automatically create a unique name (e.g. srm.1) but still show it as you have input it in this page (e.g. srm). It s time to configure the RPO (i.e., how frequently replication occurs, which results in the max age of a recovered VM); with Tintri OS 3.1 the shortest possible RPO is 15 minutes, which can be obtained by selecting a custom interval, then Hourly and then clicking the minutes past the hour box: 21

22 Configure whether the replicas need to be Crash-consistent or VM-consistent : Default setting is Crash-consistent, which means that when the VMs come up in the Recovery site, they will do so as if the power plug had been pulled out meaning they will cold boot and check the file system, etc. You can however select "VM-consistent", which means that before taking a Tintri snapshot for replication, the VM will be quiesced by leveraging VMware Tools and VSS.. The disadvantage of using VM-consistent snapshots in any VMware environment, irrespective of whether a VMstore is being used, is that if the VMs perform heavy I/O, VMware's quiescing process can take minutes and negatively impact the performance of the VM. This may be OK if the RPO is long and the snapshots are taken during low-i/o periods, but an RPO of 15 minutes may generate frequent snapshots during high-i/o periods resulting in unacceptable performance. DO: We recommend trying VM-consistent first in a test environment, with copies of the production applications and testing if the impact is acceptable or not. After pressing Create, you will see your newly created Service Group show up in the GUI, as shown above. Note the number of VMs shown and keep an eye on the RPO this will be updated as replication is performed. DO: Create a Service Group for each SRM Array Manager Pair i.e. pair between Protected and Recovery VMstores that you plan on creating in SRM. There is a 1:1 mapping between Tintri Service Groups and SRM Array Manager Pairs. 22

23 VMstore in the Recovery Site The VMstore in the Recovery Site will automatically be updated with the other side of the Service Group. In our example, this is what you re going to see on the Recovery VMstore: Add Array Manager and Enable Array Pair Now it s time to go back to the vsphere Web Client and continue the steps to configuring SRM. The next step is Add array manager and enable array pair. DON T: Try and Add a pair of array managers before you create the corresponding Service Group in the Primary s VMstore. The array manager pair creation in SRM will fail if there isn t a corresponding Service Group already created via the Tintri GUI. First we are asked if it s really adding a pair, or only one; at this stage, it is the former: 23

24 By pressing Next we are taken to the Location dialog, which, given we ve already paired the two vsphere Servers (sites), should be pre-populated with the right info: Next comes selecting the SRA, which, if you installed the SRA in the SRM servers as mentioned earlier, should also be correctly pre-populated: 24

25 After that you will be asked for the information of the VMstore in the Protected site: NOTE: if you forgot to create a Protection Group in the VMstore you input in the Configure array manager screen, you will get an error after you click Next and will not be able to proceed. If that happens, please go back to Configure the Tintri VMstores in page 18. If the Protected site s array manager configuration is successful, it is then time to input the information for the VMstore in the Recovery site: 25

26 The next screen is also auto-populated with the newly discovered Array Pair: If you re wondering, the array pair that is not selected and says No peer array pair shows a replication path that was configured to a different VMstore (i.e. that is not the one in the Recovery site). Even though that other replication path does show up, because the additional VMstore is not configured in SRM (as it shouldn t there s no Protection Group associated with it), SRM doesn t see it as an array pair and it can t be selected. That was the last step in Array Manager creation: 26

27 This is a good point for a quick sanity check. Go to Site Recovery Array Based Replication and select the VMstore in the Protected site. Then select the Manage tab and look under Array Pairs. Then select the Array Pair you just created you should see, below, no errors, and a table that has: Local Device the name of the Service Group you created in the Tintri GUI Status Outgoing Replication Remote Device also the name of the Service Group you created in the Tintri GUI Datastore the name of the Datastore you re replicating / protecting in the protected site. If all looks correct, time to proceed to create a Protection Group. Create a Protection Group Give it a name: 27

28 The type should be already correctly selected by default: You ll need to correctly select the Datastore in the next screen (make sure you select the one which is already being replicated by the VMstore): 28

29 The Virtual Machines residing in that datastore will be automatically selected. There is no way to unselect (unprotect) certain VMs here, that s why we had to create a dedicated datastore for them (so that only the ones we want to protect get replicated and protected). Next comes an optional description and that s it! SRM will be working on the VMs for a few minutes to protect them. This is what you ll see in the Web Client: Once that s finished, the status changes to this: 29

30 Create Recovery Plan Now it s time to create the recovery plan the last configuration step, right before we can actually test SRM. First, give it a name: Then, a recovery site (default should be correct): Next, the Protection Group (you just created): 30

31 Test networks are next, for what to do during a test failover. By default, SRM will place each virtual machine in an isolated "bubble" network for a test, and not connect the machines to an actual physical uplink. Then there s an optional description and that s it: Recovery plans are ready immediately after creation: 31

32 Testing Previous sections showed the entire configuration that was needed. Now it s time to do a Test Recovery Plan. As explained earlier, a Recovery Plan doesn t actually fail over the VMs to the Recovery site; what it does do is synchronize the replica VMs and then enable (power up) the VMs in the Recovery Site, in a test (isolated) network. That shows the replica VMs are OK and working. What it doesn t do is disable the VMs in the Protected site and yield full control to the VMs in the Recovery Site. Yielding full control would mean that the Recovery Site VMs would now be the Primaries, be connected to the production network and be the authoritative copy. In a Test run the Protected Site still has the authoritative copy of the VMs, and when the test ends and SRM cleans up, it simply shuts down the Recovery VMs and overwrites them with a new replica from the Protected site. In an actual failover/failback scenario (as we ll see), the VMs in the Recovery site have to be replicated back to the Protected site before they are brought up. Test Recovery Plan Here s how a typical Test Recovery Plan process looks like: 32

33 The Monitor tab will show you what s going on as it happens: Here s the screen after a successful test; note how blazingly fast the replication happens; these are 67 live VMs that get replicated in about a minute by the VMstore. This is made possible because the VMstore replicates only changed blocks after deduplication and compression. 33

34 This chart from the Tintri GUI also shows how little impact the replication process has on the Protected VMstore, even if it s set to replicate every 15 minutes and there are 67 extremely active VMs: After a test, don t forget to press the Cleanup button Otherwise a Disaster Recovery won t work correctly. A cleanup, amongst other things, removes the test network from the Recovery Site. 34

35 Running a Recovery Plan A Recovery Plan should only be actually run if there s some kind of event at the Primary (Protected) Site that mandates it. A Recover Plan should not be run for testing purposes; for that there s the Test feature described in the previous section. DON T Run a Recovery Plan for testing; use the Test Recovery Plan feature for testing. If you do Run a Recovery Plan, the Recovery site will completely take over and the VMs in the Protected Site will be taken down. Even if there s an actual Disaster Recovery situation (the Protected site goes down hard), you will still need to run the Recovery Plan as soon as you get the chance. This is because the Run Recovery Plan process does a lot of housekeeping items that don t necessarily get performed automatically if the Protected site goes down. The only difference is that when you run the Recovery Plan in a Disaster Recovery situation (rather than a planned migration) you select a different option when you trigger it: 35

36 SRM needs confirmation before proceeding: Disaster Recovery and Planned Migrations were tested in writing this document. In the DR case, the Recovery Site was running Recovered VMs in less than 2 minutes after the plug was pulled on the protected site. The whole Recovery Plan process (including housekeeping) took about 4 minutes in both cases: 36

37 Reprotect After a Recovery Plan has completed (successfully), the Failback to the Protected site is performed by clicking the Reprotect button: 37

38 With SRM and Tintri, pressing the button will perform the reversal fully automatically; the replication will automatically be reversed, as shown in the vsphere Web Client: as well as the Tintri GUI; here s what the Recovery Site VMstore looks like (note the State = Failover Primary ): and the Protected Site VMstore, showing FailoverFormerPrimaryExpectingReverse : 38

39 Conclusion Tintri VMstore was designed from the ground up for virtualization and cloud workloads, and purposebuilt to take full advantage of flash technology. Tintri s legendary ease of use and low TCO now extends to VMware SRM too: you can have your SRMbased Disaster Recovery environment up and running in mere minutes, with low maintenance and an unbeatable low TCO. Thank you for choosing Tintri. We hope the options and guidance presented in this guide enable you to leverage this new technology. For additional information about Tintri VMstores and other technical whitepapers and resources, visit

40 References Tintri Tintri SRA for VMware SRM 1.0 Release Notes Tintri VMstore System Administration Manual VMware vcenter Site Recovery Manager Features vcenter Site Recovery Manager Resources SRM 5.8 Datasheet SRM 5.8 Release Notes SRM 5.8 Documentation Center Microsoft Things to consider when you host Active Directory domain controllers in virtual hosting environments Running Domain Controllers in Hyper-V (NOTE: also applies to VMware vsphere) AD DS Backup and Recovery Step-by-Step Guide 40

41 Tintri, Tintri VMstore, the Tintri Logo and FlashFirst are trademarks or registered trademarks of Tintri, Inc. All other trademarks or service marks are the property of their respective holders and are hereby acknowledged Tintri, Inc. All rights reserved T Ravendale Dr., Mt. View CA

Tintri Deployment and Best Practices Guide

Tintri Deployment and Best Practices Guide TECHNICAL WHITE PAPER Tintri Deployment and Best Practices Guide for VMware vcenter Site Recovery Manager www.tintri.com Revision History Version Date Description Author 1.3 12/15/2017 Updated Bill Roth

More information

Site Recovery Manager Installation and Configuration. Site Recovery Manager 6.0

Site Recovery Manager Installation and Configuration. Site Recovery Manager 6.0 Site Recovery Manager Installation and Configuration Site Recovery Manager 6.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

Site Recovery Manager Installation and Configuration. Site Recovery Manager 6.5

Site Recovery Manager Installation and Configuration. Site Recovery Manager 6.5 Site Recovery Manager Installation and Configuration Site Recovery Manager 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

Site Recovery Manager Installation and Configuration. Site Recovery Manager 5.5

Site Recovery Manager Installation and Configuration. Site Recovery Manager 5.5 Site Recovery Manager Installation and Configuration Site Recovery Manager 5.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

Site Recovery Manager Installation and Configuration. Site Recovery Manager 5.8

Site Recovery Manager Installation and Configuration. Site Recovery Manager 5.8 Site Recovery Manager Installation and Configuration Site Recovery Manager 5.8 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

NexentaStor Storage Replication Adapter User Guide

NexentaStor Storage Replication Adapter User Guide NexentaStor 5.1.1 Storage Replication Adapter User Guide Date: January, 2018 Part Number: 3000-nxs-SRA-User-Guide-5.1.1-000092-A Copyright 2018 Nexenta Systems TM, ALL RIGHTS RESERVED Notice: No part of

More information

Tintri Cloud Connector

Tintri Cloud Connector TECHNICAL WHITE PAPER Tintri Cloud Connector Technology Primer & Deployment Guide www.tintri.com Revision History Version Date Description Author 1.0 12/15/2017 Initial Release Bill Roth Table 1 - Revision

More information

VMware Site Recovery Installation and Configuration. VMware Site Recovery Site Recovery Manager 8.0 vsphere Replication 8.0

VMware Site Recovery Installation and Configuration. VMware Site Recovery Site Recovery Manager 8.0 vsphere Replication 8.0 VMware Site Recovery Installation and Configuration VMware Site Recovery Site Recovery Manager 8.0 vsphere Replication 8.0 You can find the most up-to-date technical documentation on the VMware website

More information

Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance

Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance An Oracle Technical White Paper March 2014; v2.1 Best Practice Guide for Implementing VMware vcenter Site Recovery Manager 4.x with Oracle ZFS Storage Appliance Introduction... 1 Overview... 2 Prerequisites...

More information

Site Recovery Manager Installation and Configuration. Site Recovery Manager 8.1

Site Recovery Manager Installation and Configuration. Site Recovery Manager 8.1 Site Recovery Manager Installation and Configuration Site Recovery Manager 8.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

vsphere Replication for Disaster Recovery to Cloud

vsphere Replication for Disaster Recovery to Cloud vsphere Replication for Disaster Recovery to Cloud vsphere Replication 5.6 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 8.1

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 8.1 vsphere Replication for Disaster Recovery to Cloud vsphere Replication 8.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE

VMware vcenter Site Recovery Manager 4.1 Evaluator s Guide EVALUATOR'S GUIDE VMware vcenter Site Recovery Manager 4.1 EVALUATOR'S GUIDE Table of Contents. Getting Started.... 3 About VMware vcenter Site Recovery Manager.... 3 About This Guide.... 3 Intended Audience.... 3 Assumptions....

More information

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.5

vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.5 vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments

More information

vsphere Replication for Disaster Recovery to Cloud

vsphere Replication for Disaster Recovery to Cloud vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

VMware vsphere Data Protection Evaluation Guide REVISED APRIL 2015

VMware vsphere Data Protection Evaluation Guide REVISED APRIL 2015 VMware vsphere Data Protection REVISED APRIL 2015 Table of Contents Introduction.... 3 Features and Benefits of vsphere Data Protection... 3 Requirements.... 4 Evaluation Workflow... 5 Overview.... 5 Evaluation

More information

Using VMware vsphere Replication. vsphere Replication 6.5

Using VMware vsphere Replication. vsphere Replication 6.5 Using VMware vsphere Replication 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this documentation, submit your

More information

VMware vsphere Replication Installation and Configuration. vsphere Replication 6.5

VMware vsphere Replication Installation and Configuration. vsphere Replication 6.5 VMware vsphere Replication Installation and Configuration vsphere Replication 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

VMware vsphere Replication Administration. vsphere Replication 8.1

VMware vsphere Replication Administration. vsphere Replication 8.1 VMware vsphere Replication Administration vsphere Replication 8.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about

More information

vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 vrealize Suite 7.0

vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 vrealize Suite 7.0 vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 vrealize Suite 7.0 vrealize Suite 7.0 Disaster Recovery by Using Site Recovery Manager 6.1 You can find the most up-to-date technical

More information

Disaster Recovery-to-the- Cloud Best Practices

Disaster Recovery-to-the- Cloud Best Practices Disaster Recovery-to-the- Cloud Best Practices HOW TO EFFECTIVELY CONFIGURE YOUR OWN SELF-MANAGED RECOVERY PLANS AND THE REPLICATION OF CRITICAL VMWARE VIRTUAL MACHINES FROM ON-PREMISES TO A CLOUD SERVICE

More information

vsphere Upgrade Update 2 Modified on 4 OCT 2017 VMware vsphere 6.0 VMware ESXi 6.0 vcenter Server 6.0

vsphere Upgrade Update 2 Modified on 4 OCT 2017 VMware vsphere 6.0 VMware ESXi 6.0 vcenter Server 6.0 Update 2 Modified on 4 OCT 2017 VMware vsphere 6.0 VMware ESXi 6.0 vcenter Server 6.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you

More information

Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual

Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual Dell PowerVault MD Storage Array VMware Storage Replication Adapter (SRA) Installation and Configuration Manual Regulatory Model: E16S Series Regulatory Type: E16S001 Notes, Cautions, and Warnings NOTE:

More information

vsphere Replication 6.5 Technical Overview January 08, 2018

vsphere Replication 6.5 Technical Overview January 08, 2018 vsphere Replication 6.5 Technical Overview January 08, 2018 1 Table of Contents 1. VMware vsphere Replication 6.5 1.1.Introduction 1.2.Architecture Overview 1.3.Initial Deployment and Configuration 1.4.Replication

More information

TECHNICAL WHITE PAPER - FEBRUARY VMware Site Recovery for VMware Cloud on AWS Evaluation Guide TECHNICAL WHITE PAPER

TECHNICAL WHITE PAPER - FEBRUARY VMware Site Recovery for VMware Cloud on AWS Evaluation Guide TECHNICAL WHITE PAPER TECHNICAL WHITE PAPER - FEBRUARY 2019 VMware Site Recovery for VMware Cloud on AWS Evaluation Guide TECHNICAL WHITE PAPER Table of Contents Introduction 4 Pre-requisites 4 Site Recovery Manager Server...

More information

vcenter Server Installation and Setup Modified on 11 MAY 2018 VMware vsphere 6.7 vcenter Server 6.7

vcenter Server Installation and Setup Modified on 11 MAY 2018 VMware vsphere 6.7 vcenter Server 6.7 vcenter Server Installation and Setup Modified on 11 MAY 2018 VMware vsphere 6.7 vcenter Server 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

VMware vsphere Replication Administration. vsphere Replication 6.5

VMware vsphere Replication Administration. vsphere Replication 6.5 VMware vsphere Replication Administration vsphere Replication 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about

More information

vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8

vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8 vrealize Suite 6.0 Disaster Recovery by Using Site Recovery Manager 5.8 vrealize Suite 6.0 This document supports the version of each product listed and supports all subsequent versions until the document

More information

SRM Evaluation Guide First Published On: Last Updated On:

SRM Evaluation Guide First Published On: Last Updated On: First Published On: 12-24-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 1.3.About This Evaluation Guide 2. Requirements 2.1.Overview 3. Evaluation Workflow

More information

VMware vsphere Replication Administration. vsphere Replication 6.0

VMware vsphere Replication Administration. vsphere Replication 6.0 VMware vsphere Replication Administration vsphere Replication 6.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about

More information

Backup and Recovery Best Practices With Tintri VMstore

Backup and Recovery Best Practices With Tintri VMstore Backup and Recovery Best Practices With Tintri VMstore Backup and Recovery Best Practices with Tintri VMstore TECHNICAL BEST PRACTICES PAPER, Revision 1.0, April 10, 2014 Contents Contents Introduction

More information

vcenter Server Installation and Setup Update 1 Modified on 30 OCT 2018 VMware vsphere 6.7 vcenter Server 6.7

vcenter Server Installation and Setup Update 1 Modified on 30 OCT 2018 VMware vsphere 6.7 vcenter Server 6.7 vcenter Server Installation and Setup Update 1 Modified on 30 OCT 2018 VMware vsphere 6.7 vcenter Server 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Site Recovery Manager Administration. Site Recovery Manager 6.0

Site Recovery Manager Administration. Site Recovery Manager 6.0 Site Recovery Manager Administration Site Recovery Manager 6.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this

More information

Site Recovery Manager Administration. Site Recovery Manager 6.1

Site Recovery Manager Administration. Site Recovery Manager 6.1 Site Recovery Manager 6.1 You can find the most up-to-date technical documentation on the VMware Web site at: https://docs.vmware.com/ The VMware Web site also provides the latest product updates. If you

More information

DELL EMC XTREMIO X2 NATIVE REPLICATION ADAPTER FOR VMWARE SITE RECOVERY MANAGER

DELL EMC XTREMIO X2 NATIVE REPLICATION ADAPTER FOR VMWARE SITE RECOVERY MANAGER REFERENCE ARCHITECTURE DELL EMC XTREMIO X2 NATIVE REPLICATION ADAPTER FOR VMWARE SITE RECOVERY MANAGER Abstract This reference architecture evaluates the best-in-class performance and scalability delivered

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

vsphere Upgrade Update 1 Modified on 4 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Upgrade Update 1 Modified on 4 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 Update 1 Modified on 4 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you

More information

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA.

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA. This solution guide describes the disaster recovery modular add-on to the Federation Enterprise Hybrid Cloud Foundation solution for SAP. It introduces the solution architecture and features that ensure

More information

Server Fault Protection with NetApp Data ONTAP Edge-T

Server Fault Protection with NetApp Data ONTAP Edge-T Technical Report Server Fault Protection with NetApp Data ONTAP Edge-T Jeff Whitaker, NetApp March 2013 TR-4154 TABLE OF CONTENTS 1 Introduction... 3 2 Backup and Disaster Recovery Technology... 4 2.1

More information

NexentaStor VVOL

NexentaStor VVOL NexentaStor 5.1.1 VVOL Admin Guide Date: January, 2018 Software Version: NexentaStor 5.1.1 VVOL Part Number: 3000-VVOL-5.1.1-000065-A Table of Contents Preface... 3 Intended Audience 3 References 3 Document

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

Dell Storage Compellent Integration Tools for VMware

Dell Storage Compellent Integration Tools for VMware Dell Storage Compellent Integration Tools for VMware Version 4.0 Administrator s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5

Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 Getting Started with ESX Server 3i Embedded ESX Server 3i version 3.5 Embedded and VirtualCenter 2.5 Title: Getting Started with ESX Server 3i Embedded Revision: 20071022 Item: VMW-ENG-Q407-430 You can

More information

Installing and Configuring vcenter Multi-Hypervisor Manager

Installing and Configuring vcenter Multi-Hypervisor Manager Installing and Configuring vcenter Multi-Hypervisor Manager vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.1.2 This document supports the version of each product listed and supports all subsequent

More information

Advanced Architecture Design for Cloud-Based Disaster Recovery WHITE PAPER

Advanced Architecture Design for Cloud-Based Disaster Recovery WHITE PAPER Advanced Architecture Design for Cloud-Based Disaster Recovery WHITE PAPER Introduction Disaster Recovery (DR) is a fundamental tool for mitigating IT and business risks. But because it is perceived as

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

Setting Up the Dell DR Series System on Veeam

Setting Up the Dell DR Series System on Veeam Setting Up the Dell DR Series System on Veeam Dell Engineering April 2016 A Dell Technical White Paper Revisions Date January 2014 May 2014 July 2014 April 2015 June 2015 November 2015 April 2016 Description

More information

Reconfiguring VMware vsphere Update Manager. 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7

Reconfiguring VMware vsphere Update Manager. 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7 Reconfiguring VMware vsphere Update Manager 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

VMware vfabric Data Director Installation Guide

VMware vfabric Data Director Installation Guide VMware vfabric Data Director Installation Guide vfabric Data Director 1.0.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Managing VMware vcenter Site Recovery Manager

Managing VMware vcenter Site Recovery Manager Managing VMware vcenter Site Recovery Manager This chapter contains the following sections: About VMware vcenter Site Recovery Manager, page 1 Overview of SRM Configuration, page 2 Integrating SRM with

More information

Dell Storage Integration Tools for VMware

Dell Storage Integration Tools for VMware Dell Storage Integration Tools for VMware Version 4.1 Administrator s Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

vcloud Air - Dedicated Disaster Recovery User's Guide

vcloud Air - Dedicated Disaster Recovery User's Guide vcloud Air - Dedicated Disaster Recovery User's Guide vcloud Air Disaster Recovery This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Evaluator Guide. Site Recovery Manager 1.0

Evaluator Guide. Site Recovery Manager 1.0 Evaluator Guide Site Recovery Manager 1.0 Site Recovery Manager Evaluator Guide 2006-2008 VMware, Inc. All rights reserved. Protected by one or more of U.S. Patent Nos. 6,397,242, 6,496,847, 6,704,925,

More information

Backup and Recovery Best Practices with Tintri VMstore and Commvault Simpana Software

Backup and Recovery Best Practices with Tintri VMstore and Commvault Simpana Software TECHNICAL WHITE PAPER Backup and Recovery Best Practices with Tintri VMstore and Commvault Simpana Software Author: Dominic Cheah (TME) August 2015 www.tintri.com Contents Intended Audience... 3 Introduction...

More information

vsphere Update Manager Installation and Administration Guide 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7

vsphere Update Manager Installation and Administration Guide 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7 vsphere Update Manager Installation and Administration Guide 17 APR 2018 VMware vsphere 6.7 vsphere Update Manager 6.7 You can find the most up-to-date technical documentation on the VMware website at:

More information

Setting Up the DR Series System on Veeam

Setting Up the DR Series System on Veeam Setting Up the DR Series System on Veeam Quest Engineering June 2017 A Quest Technical White Paper Revisions Date January 2014 May 2014 July 2014 April 2015 June 2015 November 2015 April 2016 Description

More information

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 vsphere Installation and Setup Update 2 Modified on 10 JULY 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5 You can find the most up-to-date technical documentation on the VMware website at:

More information

VMware vfabric Data Director Installation Guide

VMware vfabric Data Director Installation Guide VMware vfabric Data Director Installation Guide vfabric Data Director 2.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by

More information

XtremIO Business Continuity & Disaster Recovery. Aharon Blitzer & Marco Abela XtremIO Product Management

XtremIO Business Continuity & Disaster Recovery. Aharon Blitzer & Marco Abela XtremIO Product Management XtremIO Business Continuity & Disaster Recovery Aharon Blitzer & Marco Abela XtremIO Product Management Agenda XtremIO Current BC/DR Offerings New BC/DR Offering Benefits of New Offering Technical Overview

More information

TECHNICAL WHITE PAPER AUGUST 2017 REVIEWER S GUIDE FOR VIEW IN VMWARE HORIZON 7: INSTALLATION AND CONFIGURATION. VMware Horizon 7 version 7.

TECHNICAL WHITE PAPER AUGUST 2017 REVIEWER S GUIDE FOR VIEW IN VMWARE HORIZON 7: INSTALLATION AND CONFIGURATION. VMware Horizon 7 version 7. TECHNICAL WHITE PAPER AUGUST 2017 REVIEWER S GUIDE FOR VIEW IN VMWARE HORIZON 7: INSTALLATION AND CONFIGURATION VMware Horizon 7 version 7.x Table of Contents Introduction.... 3 JMP Next-Generation Desktop

More information

REVISED 1 AUGUST REVIEWER'S GUIDE FOR VMWARE APP VOLUMES VMware App Volumes and later

REVISED 1 AUGUST REVIEWER'S GUIDE FOR VMWARE APP VOLUMES VMware App Volumes and later REVISED 1 AUGUST 2018 REVIEWER'S GUIDE FOR VMWARE APP VOLUMES VMware App Volumes 2.13.1 and later Table of Contents Introduction Audience What You Will Learn Navigating This Document for App Volumes Use

More information

Getting Started with ESXi Embedded

Getting Started with ESXi Embedded ESXi 4.0 Embedded vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

Tech Note: vsphere Replication with vsan First Published On: Last Updated On:

Tech Note: vsphere Replication with vsan First Published On: Last Updated On: Tech Note: vsphere Replication with vsan First Published On: 10-27-2017 Last Updated On: 11-01-2017 1 Table of Contents 1. Introduction 1.1.Introduction 2. vsphere Replication with vsan Datastores 2.1.vSphere

More information

vsan Disaster Recovery November 19, 2017

vsan Disaster Recovery November 19, 2017 November 19, 2017 1 Table of Contents 1. Disaster Recovery 1.1.Overview 1.2.vSAN Stretched Clusters and Site Recovery Manager 1.3.vSAN Performance 1.4.Summary 2 1. Disaster Recovery According to the United

More information

VMware Validated Design Site Protection and Recovery Guide

VMware Validated Design Site Protection and Recovery Guide VMware Validated Design Site Protection and Recovery Guide VMware Validated Design for Software- Defined Data Center 3.0 This document supports the version of each product listed and supports all subsequent

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

Backup and Recovery Best Practices with Veeam Backup & Replication

Backup and Recovery Best Practices with Veeam Backup & Replication TECHNICAL WHITE PAPER Backup and Recovery Best Practices with Veeam Backup & Replication www.tintri.com Revision History Version Date Description Author 1.2 01/05/2018 Updated Release Bill Roth 1.1 07/11/2016

More information

Step by Step ASR, Azure Site Recovery

Step by Step ASR, Azure Site Recovery Prepared by: Mohammad Asmayal Jawad linkedin.com/in/asmayal/ August 14, 2017 V1.0 Table of Contents WORK LOADS PROTECTED... 1 DEPLOYMENT STEPS... 1 PREREQUISITES...2 LIMITATIONS... 3 SET UP AZURE... 4

More information

Horizon Console Administration. 13 DEC 2018 VMware Horizon 7 7.7

Horizon Console Administration. 13 DEC 2018 VMware Horizon 7 7.7 Horizon Console Administration 13 DEC 2018 VMware Horizon 7 7.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this

More information

HP StoreOnce Recovery Manager Central for VMware User Guide

HP StoreOnce Recovery Manager Central for VMware User Guide HP StoreOnce Recovery Manager Central 1.2.0 for VMware User Guide Abstract The guide is intended for VMware and database administrators who are responsible for backing up databases. This guide provides

More information

VMware Mirage Getting Started Guide

VMware Mirage Getting Started Guide Mirage 5.8 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,

More information

REVISED 1 AUGUST QUICK-START TUTORIAL FOR VMWARE APP VOLUMES VMware App Volumes and later

REVISED 1 AUGUST QUICK-START TUTORIAL FOR VMWARE APP VOLUMES VMware App Volumes and later REVISED 1 AUGUST 2018 QUICK-START TUTORIAL FOR VMWARE APP VOLUMES VMware App Volumes 2.13.1 and later Table of Contents Introduction Audience What You Will Learn Navigating This Document for App Volumes

More information

VMware vcenter Site Recovery Manager disaster recovery best practices

VMware vcenter Site Recovery Manager disaster recovery best practices Tutorial VMware vcenter Site Recovery Manager disaster recovery best practices VMware Inc. released Site Recovery Manager (SRM) in June 2008 to provide an automated solution for failover of virtual environments

More information

Veeam Backup & Replication for VMware vsphere

Veeam Backup & Replication for VMware vsphere Veeam Backup & Replication for VMware vsphere Version 9.5 Evaluator's Guide December, 2017 2017 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

BC/DR Strategy with VMware

BC/DR Strategy with VMware BC/DR Strategy with VMware VMware vforum, 2014 Andrea Teobaldi Systems Engineer @teob77 2014 VMware Inc. All rights reserved. What s on the agenda? Defining the problem Definitions VMware technologies

More information

Dell Storage Compellent Integration Tools for VMware

Dell Storage Compellent Integration Tools for VMware Dell Storage Compellent Integration Tools for VMware Administrator s Guide Version 3.1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

vrealize Suite 7.0 Backup and Restore by Using Veritas NetBackup 7.6 vrealize Suite 7.0

vrealize Suite 7.0 Backup and Restore by Using Veritas NetBackup 7.6 vrealize Suite 7.0 vrealize Suite 7.0 Backup and Restore by Using Veritas NetBackup 7.6 vrealize Suite 7.0 vrealize Suite 7.0 Backup and Restore by Using Veritas NetBackup 7.6 You can find the most up-to-date technical documentation

More information

Storage Replication Adapter for VMware vcenter SRM. April 2017 SL10334 Version 1.5.0

Storage Replication Adapter for VMware vcenter SRM. April 2017 SL10334 Version 1.5.0 Storage Replication Adapter for VMware vcenter SRM April 2017 SL10334 Version 1.5.0 1 Introduction This lab introduces the fundamentals of VMware vcenter Site Recovery Manager on clustered Data ONTAP.

More information

Dell EMC vsan Ready Nodes for VDI

Dell EMC vsan Ready Nodes for VDI Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

VMware vsphere Replication Administration

VMware vsphere Replication Administration VMware vsphere Replication Administration vsphere Replication 5.8 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

Tintri VMstore for Dev/Test Environment

Tintri VMstore for Dev/Test Environment Technical White Paper Tintri VMstore for Dev/Test Environment December 2015 www.tintri.com Contents Executive Summary... 1 Snapshots... 2 Use Cases.... 2 Tintri VMstore Snapshot Benefits... 2 Clones....

More information

VMware HCX Enterprise Install and User Guide. For On-Premise Environments

VMware HCX Enterprise Install and User Guide. For On-Premise Environments VMware HCX Enterprise Install and User Guide For On-Premise Environments Contents ABOUT THIS GUIDE 3 INTENDED AUDIENCE 3 SUPPORT RESOURCES 3 ABOUT HCX 4 OVERVIEW 4 COMPONENTS 5 HCX INSTALLATION PREREQUISITE

More information

VMware vsphere Replication Administration. vsphere Replication 5.8

VMware vsphere Replication Administration. vsphere Replication 5.8 VMware vsphere Replication Administration vsphere Replication 5.8 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about

More information

Installing VMware vsphere 5.1 Components

Installing VMware vsphere 5.1 Components Installing VMware vsphere 5.1 Components Module 14 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Administration Guide for 7.2 release June 2018 215-13169_A0 doccomments@netapp.com Table of Contents 3 Contents

More information

Using Double-Take Software and the Virtual Recovery Appliance

Using Double-Take Software and the Virtual Recovery Appliance Using Double-Take Software and the Virtual Recovery Appliance When considering a BCP (Business Continuity Planning) solution for your application server environment, one product that you should definitely

More information

SRM 8.1 Technical Overview First Published On: Last Updated On:

SRM 8.1 Technical Overview First Published On: Last Updated On: First Published On: 12-23-2016 Last Updated On: 04-17-2018 1 Table of Contents 1. Introduction 1.1.Overview 1.2.Terminology 2. Architectural Overview 2.1.Overview 3. Use Cases 3.1.Overview 3.2.Disaster

More information

Data Protection for Cisco HyperFlex with Veeam Availability Suite. Solution Overview Cisco Public

Data Protection for Cisco HyperFlex with Veeam Availability Suite. Solution Overview Cisco Public Data Protection for Cisco HyperFlex with Veeam Availability Suite 1 2017 2017 Cisco Cisco and/or and/or its affiliates. its affiliates. All rights All rights reserved. reserved. Highlights Is Cisco compatible

More information

Automated Disaster Recovery. Simon Caruso Senior Systems Engineer, VMware

Automated Disaster Recovery. Simon Caruso Senior Systems Engineer, VMware Automated Disaster Recovery Simon Caruso Senior Systems Engineer, VMware What is a Disaster? Complete loss of a data center for an extended period of time Declaration of a disaster usually requires consensus

More information

Application Notes for Installing and Configuring Avaya Control Manager Enterprise Edition in a High Availability mode.

Application Notes for Installing and Configuring Avaya Control Manager Enterprise Edition in a High Availability mode. Application Notes for Installing and Configuring Avaya Control Manager Enterprise Edition in a High Availability mode. Abstract This Application Note describes the steps required for installing and configuring

More information

VMware vcloud Director Infrastructure Resiliency Case Study

VMware vcloud Director Infrastructure Resiliency Case Study ware vcloud Director Infrastructure Resiliency Case Study ware vsphere 5.0, ware vcenter Site Recovery Manager 5.0 and ware vcloud Director 1.5 TECHNICAL WHITE PAPER v 1.0 February 2012 ware vcloud Director

More information

HPE 3PAR Storage Replication Adaptor for Stretched storage support with VMware vcenter Site Recovery Manager. Technical White Paper

HPE 3PAR Storage Replication Adaptor for Stretched storage support with VMware vcenter Site Recovery Manager. Technical White Paper HPE 3PAR Storage Replication Adaptor for Stretched storage support with VMware vcenter Site Recovery Manager Technical White Paper Contents Introduction... 3 Scope of the document... 3 Document purpose...

More information

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family A step-by-step guide IBM Systems and Technology Group ISV Enablement February 2014 Copyright IBM Corporation, 2014 Table of contents

More information

VMware vsphere with ESX 6 and vcenter 6

VMware vsphere with ESX 6 and vcenter 6 VMware vsphere with ESX 6 and vcenter 6 Course VM-06 5 Days Instructor-led, Hands-on Course Description This class is a 5-day intense introduction to virtualization using VMware s immensely popular vsphere

More information

vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.4

vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.4 vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.4 vrealize Operations Manager Customization and Administration Guide You can find the most up-to-date technical

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For Microsoft Exchange Server March 2018 215-12936_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read the SnapCenter Data Protection

More information

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Application notes Abstract These application notes explain configuration details for using Infortrend EonStor DS Series iscsi-host

More information

Understanding Virtual System Data Protection

Understanding Virtual System Data Protection Understanding Virtual System Data Protection Server virtualization is the most important new technology introduced in the data center in the past decade. It has changed the way we think about computing

More information