Plugs (in-line sockets) for solenoid actuated hydraulic valves
|
|
- Augustine Preston
- 5 years ago
- Views:
Transcription
1 Plugs (inline sockets) for soleid actuated hydraulic valves Plugs conforming DIN 3 60 model A (ISO 00), see sect. 2. Central plugs (nstandard), see sect. 2.3 Plugs (slim design) acc. to industrial standard with blade terminal width, see sect General The soleid actuation of a hydraulic valve is indicated in the type coding via the abbreviated supply voltage for the specified soleid coil (G = DC / WG = AC), see type coding key of the respective pamphlet of the valve. It is t detailed which plug is to be used, as they are scope of delivery for the specific valve. When the valve is desired without plug, this has to be indicated on the order coding, see sect.. When a desired hydraulic valve should come with nstandard plugs with different inserts, this has to be specified in clear text added to the order coding. Soleid valves generate voltage peeks as well as electromagnetic fields, when they are energized and deenergized when interference suppressors are used. This can cause malfunctions of electronic equipment or appliances which are nearby. The term EMC, means that the soleid valve is sufficiently screened to protect electronic installations nearby. The cheapest and simplest method to shield soleid valves is to install an interference suppressor in parallel with the coil. The plugs described in this data sheet were mainly selected because of their stateoftheart EMC Plugs equipped with a interference suppressor (clamp diode) guarantee the highest degree of EMC, but they considerably prolong the cutoff time of the hydraulic valve. A sufficient protection with only minimal increase in cutoff time can be achieved by using one of the following: a) two Zdiodes connected in series in opposite direction b) DR resistor (varistor) c) suppressor diode. D 763 HAWE Hydraulik SE STREITFELDSTR MÜNCHEN Socket (plugs) 78 by HAWE Hydraulik December
2 D 763 page 2 2. Available versions, electrical characteristics Air and creep paths conforming DIN DE 00, excess voltage class 2. Housing material: self extinguishing plastic 2. Plugs conforming DIN 3 60, type A (ISO 00) Protection class IP 6 conforming DIN EN 602 or IEC 602, when properly mounted and fixed cross section area temperature. MSD 330 ) MSD 330 ) grey 20 DC/AC 20 DC/AC.. Standard: Black housing (Bplugs) suited for all single and double acting, reverse acting and twin soleids. When used for single acting soleids, terminal 3 is unused. Grey housing (Aplugs) only with 3/way directional spool valves type SW... according to D 70 and D 7 (also with lifting module acc. to D 760 and clamping module acc. to D Black plugs are also standard with prop. soleids 0 3 and 0 when amplifier plug acc. to D 788 is ordered (see also.). Pin 3 unused MSD 30 P22 ) MSD 20 P0 ) AC 20 AC.. 2x half bridge rectifiers full bridge rectifiers Rectifier plugs for DC soleids when used with AC mains (0 and 60 Hz). MSD 30 P22 MSD 20 P0 MSD 20 P0 with full bridge rectifier 2 ) 3 ) for single acting soleids with coils 8 DC for mains 0 AC or coils 20 DC for mains 230 AC. U DC = 0. U AC 2 MSD 30 P22 with two half bridge rectifiers and clamp diode 2 ) 3 ) for electric double and reverse acting soleids as well as twin soleids with 02 DC coils for 230 AC mains or 8 DC coils for 0 AC mains. U DC = 0. U AC MSD 320 C MSD 30 C+R MSD 30 C DC 2 DC 20 DC... D D+R 2D With clamp diodes 2 ) to suppress cutoff voltage spikes i.e. used in connection with electronic circuits and/or to achieve a longer fall (release) time. Caution: Polarity sensitive there is reverse voltage protection! MSD 320 C for single acting soleids. MSD 30 C +R for lift monitored 2/2way directional valves according to Sk 7380 a to d and Sk 7380 E and F. MSD 30 C2 for DC for electric double and reverse acting soleids as well as twin soleids. MSD 320 C MSD 30 C+R MSD 30 C2 SS SS grey 2 DC/AC 2 DC/AC Z+LED yellow Z+LED yellow SS and SS 2608 with yellow LED and interference protection via two Zdiodes. For 2 DC/AC t polarity sensitive, both covers are translucent. Larger housing as with type MSD 20 P3.
3 D 763 page 3 cross section area temp. SS 2636 MSE DC 2 DC SS Z+LED ye/gr Switch amplifier 2LED gr/red LED indicator for twin, double acting and reverse acting soleids. SS 2636 with LED indication (green and yellow) and interference protection via two Zdiodes, use for 2 DC/AC, t polarity sensitive, translucent cover. MSE with PLC capable amplifier and LED indication (green and red) Supply voltage DC, interference protection via two Zdiodes, control voltage from DC, control current 7 to ma. MSE SS DC/AC LED red/green Plug for 2. To indicate the status on pressure switch according to D 0. SS 2600 for AC and DC with LED indication (green and red), translucent cover. MSD P3 MSD P transl. transl. 230 AC AC LED red LED red Time controlled rectifier, full/half bridge, as ecomy circuit for single acting soleids, mains 230 and 0 AC Hz. MSD P3 for WG 230 (230 AC, as in IEC 38). MSD P63 for WG 0 (0 AC). For more details, see D 783. MSD P MSE transl. 2 DC 2 DC LED yellow LED yellow Plugs with builtin ecomy circuit for single acting soleids 2 DC. MSD P with fixed switching time and reduced (ecomy) voltage. For more details, see D 7833 MSE with adjustable reduced (ecomy) voltage as well as PLC capable amplifier. For more details, see D MSD P MSE ) D = diode R = resistor Z = a series connection of two Zdiodes in opposition LED = light emitting diode rt = red, gn = green, ge = yellow 2) Caution: The diodes will increase the release time of the valve two to fivefold or more, depending on size of the soleid and valve design 3) Diodes N 007, surge peak reverse voltage 000, minal current A ) Plug allready included with order of soleid operated hydraulic valve according to respective data sheet, a special or additional te is t required
4 D 763 page 2.2 Plugs with slim design, acc. to industrial standard (blade terminal width Protection class IP 6 conforming DIN EN 602 or IEC 602, when properly mounted and fixed crosssect. temp. MSD 620 SS DC/AC 2 DC/AC Z+LED yellow Type MSD 620 is standard for all single acting soleids with plug 20 x 27 and blade, e.g. size 0 valves with AC soleids acc. to D 7300, but also standard with prop. soleids 0 2, when amplifier plug acc. to D 78 is ordered. SS with LED indicator (yellow) and interference protection via two Zdiodes. For 2 DC/AC, t polarity sensitive, translucent cover. MSD 620 SS Central plugs (t standardized) Protection class IP conforming DIN 602 or IEC 602, when properly mounted and fixed crosssect. temp. MSD MSD D MSD MSD DC/AC 20 DC/AC 20 DC/AC No emerg. actuat. Adapter for DIN 3 60 A Type MSD is standard for valves size (acc. to D 7300). Emergency manual actuation by pressing down the cap (rubber cap is scope of delivery) MSD D is without rubber cap and emergency hand actuation. Adapter version type MSD MSD 3 is to convert from MSD to plug conforming DIN 3 60 A (see sect. 2.). For order coding, see D 7300, sect MSD MSD D MSD MSD 3 MSD 2 MSD 2 C MSD 2MSD 3 MSD 2MSD 3 WG ) DC/AC 20 DC 20 DC 20 DC/AC Type MSD 2 is standard for valves size 0 (acc. to D 7300). Emergency manual actuation by pressing down the cap (rubber cap is scope of delivery) MSD D is without rubber cap and emergency hand actuation. Type MSD 2 C is with clamp diodes 2 ) to suppress cutoff voltage spikes i.e. in connection with electronic circuits and/or to achieve a longer fall (release) time. Caution: Polarity sensitive there is reverse polarity protection! Adapter version type MSD 2MSD 3 is to convert from MSD2 to plug conforming DIN 3 60 A (see sect. 2.). For order coding, see D 7300, sect Adapter MSD 2MSD 3 WG with additionally included full bridge rectifier 2) 3 ) ) D = Diode; Z = Two Zdiodes connected in series in opposite direction LED = rt = red, gn = green, ge = yellow 2) Caution: The diodes will prolong the releasing time of the valve by 2 to times depending on soleid size and valve design 3) Diodes N 007, surge peak reverse voltage 000, minal current A ) Plug allready included with order of soleid operated hydraulic valve according to respective data sheet, a special or additional te is t required.. M2 M2 MSD 2 MSD 2 MSD 3 Alternatively PE lead connection depending on mounting direction of plug D Full bridge rectifier MSD 2 C MSD 2 MSD 3 WG
5 D 763 page 3. Dimensions (all dimensions in, subject to changes!) 3. Plugs conforming DIN 3 60 T., type A (ISO 00) Type MSD 330 MSD 330 grey MSD 320 C MSD 30 C2 Screw driver slot for easy dismantling of insert MSD 30 C+R MSD 20 P0 MSD 30 P22 MSD P3 MSD P63 MSD P Connector is t used with two terminal versions Type SS SS 2608 grey SS 2600 SS 2607 Connector is t used with two terminal versions Illustration without seal Housing x 0 rotatable Illustration without seal Housing x 0 rotatable approx. slackened approx. 0 slackened a/f 7 a/f 6 Profiled seal Flat seal Flat seal Type MSED (dimensions also apply to type MSE 28026) 2 = coil b + = Protective conductor (ground) = GND, coon 3 = Coil a + + = Supply voltage A = Control input a B = Control input b Flat seal = GND PE = Grounding conductor Cable gland Housing rotatable left hand side max. 0, right hand side max. 80
6 D 763 page Plugs slim design Type MSD620 Type SS Screw driver slot for easy dismantling of insert Housing x 0 rotatable Illustration without seal Illustration without seal Housing x 0 rotatable approx. slackened approx. 0 slackened a/f 7 a/f 6 Flat seal Flat seal 3.3 Central plugs Type MSD Type MSD MSD 3 Type MSD 2 Type MSD 2MSD 3 MSD 2 C MSD 2MSD 3 WG For additional dimensions, see type MSD! For additional dimensions, see type MSD!. Devices delivered without plug Should the customer wish to use his own plug the devices can be delivered without. The of the soleid are protected by a plastic cap. Typical order coding for valve without plug WN SX2, WH HX6 2 ) (D 770 A) W 3 2 X 220 (D 7300) SG 3G MD 2/X 2 (D 60) SG L MD 8 X (D 600) ) These codings are currently t listed in the respective data sheets, but they can be used for orders making a suffix in uncoded text superfluous. 2) For DC soleids which are supplied from the AC mains via a bridge rectifier, the coil voltage U DC, 0.8 U AC must be indicated. For DC soleids which are supplied from the AC mains via a oneway rectifier the coil voltage U DC, 0. U AC must be indicated.
DIN Molded Cable Assemblies
DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationpoles type cable gland type or connection color approvals order no.
DIN 43650-A/ISO 4400 GDM Series Cable socket, self-assembly Product description durable angled connectors, dust and splash protected (IEC 60529 IP 65) vibration-proof locking using a central screw available
More information26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.
66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual
More informationSolid State Remote Power Controller E /627
Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves
More informationValve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)
Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface
More informationPower Supply HARTING pcon
HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationMating connectors and cable sets for valves and sensors in hydraulics
s and cable sets for valves and sensors in hydraulics RE 08006 Edition: 06-04 Replaces: 0. Features s and cable sets for electrical connection of: - Valve solenoids - Valves with integrated electronics
More informationTRIO-DIODE/12-24DC/2X10/1X20
Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationPSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems
Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationPower Supply HARTING pcon
HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationDevice manual AS-i PowerSwitch ZB0028 ZB0040
Device manual AS-i PowerSwitch ZB0028 ZB0040 System AS-i Page 1 of 16 Device manual POWERSWITCH ZB0028 ZB0040 Date: 04/02/02 Contents 1. Views... 3 1.1 Top view... 3 1.2 Front view... 4 1.3 Bottom view...
More informationMating connectors and cable sets for valves and sensors in hydraulics
Mating connectors and cable sets for valves and sensors in hydraulics RE 08006/0. Replaces: 04. /4 Table of contents See page to 5 Features Mating connectors and cable sets for the electrical connection
More information26360, NAMUR. Technical data
66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual
More informationSafety Switches CES-AR/CET-AR
CES-A-L XXXXXX Safety Switches Component overview for non-contact safety switches Connection cable Safety switch Actuator Bolt CES-A-BBA Page 1 CES-A-BCA Page 1 Page 10 CES-AR-C01-... Page 10 CES-A-BPA
More informationScrew terminal panels, Relay output boards, connection cables
Screw terminal panels, Relay output boards, connection cables How important are cables and terminal panels? When the PC runs important controlling and regulating tasks in a processing system, then data
More informationThe connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves.
Connector Connector system The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves. The connectors with cable entry conform
More informationProximity sensors SME-8, for T-slot Technical data Magnetic reed
Function e.g. N/O contact, with cable, 3-wire Magnetic reed measuring principle Insertable in the slot lengthwise e.g. N/O contact, with plug, 3-pin SME-8-SL Sturdy thanks to long guides Plug directly
More informationTemperature Switches
ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationInstallation / Control Technique
Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More information4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus
4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationProducts no longer available
echnical data sheet NVF4-MF(-E)-R Modulating linear actuator with emergency function for -way and 3-way globe valves Actuating force 800 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position
More informationConnector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable
44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in
More informationOperating Instruction for Turbine-wheel Flow Meter. Model: DRS
Operating Instruction for Turbine-wheel Flow Meter Model: DRS . Contents. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
More informationCapacitive Proximity Sensor E2K-C
3 to 5 mm, adjustable Sensing Supply voltage Output 9 to 5AC, 5/6 Hz 1 to 4DC ma ma, NPN or PNP Capacitive Proximity Sensor Cylindrical Sensor Offers Adjustable Detecting Distance Permits non-contact detection
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationProduct and functional description
Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect
More informationProgrammable logic valve control with PROFIBUS type PLVC 2
Programmable logic valve control with PROFIBUS type PLVC 2 See also other electronic valve controller/accessory: Type PLVC 4 acc. to D 7845-4 Type PLVC-CAN acc. to D 7845 Z Type CAN-HMI acc. to D 7845
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationProducts no longer available
echnical data sheet NV4-MF(-) Modulating linear actuator for -way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position osition feedback feedbac
More informationRelays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications
RSC Series RSC Series Solid State Relays Key features of the RSC series include: Slim design allows for DIN rail or panel mounting Built-in heat sink maximizes current output capability Epoxy-free design
More informationHa-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features
2000 Fast and Full Gigabit Ethernet Basic Commercial Temp.: / Industrial Temp.: Power Sourcing Equipment (PSE) with 4 Ports PoE+ (34.2 watts per port) General description Unmanaged Ethernet switches of
More information5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4
5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 Products 5/2 Directional-control valve, single valve, electrical connection M8 (4 poles) 5/3 Directional-control valve, single valve, electrical
More informationProgrammable logic valve control type PLVC 8
Programmable logic valve control type PLVC 8 See also other electronic valve controller/accessory: Type PLVC 4 D 7845-4 Type PLVC 2 D 7845-2 Type PLVC-CAN D 7845 Z Type CAN-HMI D 7845 HMI 1. General information
More informationManual Industry Interfaces
Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationDuct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for
More informationRoHS. High shaft load capacity. Shock / vibration resistant
Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up
More informationIndustrial Hydraulics FAQs
Industrial Hydraulics FAQs FAQ Title: Z versus K or K0 in model code Category: Proportional & Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 5 City Line Road
More informationProgrammable logic valve control type PLVC 8
Programmable logic valve control type PLVC 8 See also other electronic valve controller/accessory: Type PLVC 41 D 7845-41 Type PLVC 2 D 7845-2 Type PLVC-CAN D 7845 Z Type CAN-HMI D 7845 HMI 1. General
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationSafety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC
Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation
More informationSafety controller unit B1 /
Version 1.0 Safety controller unit 470111B1 / For 2 to 16 safety sensors 470115B1 PL d in acc. with EN ISO 13849-1 / SIL CL 2 in acc. with EN IEC 62061 Two safety outputs and external contactor monitoring
More informationElectronic Control Unit RC
Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Electronic Control Unit RC RE 900/.0 /6 Replaces: 09.0 Series
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationCONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11
CONTROL CABINET KR C1 A Technical Data 1of 11 e Copyright KUKA Roboter GmbH This documentation or excerpts therefrom may not be reproduced or disclosed to third parties without the express permission of
More informationStandard-Signal Isolation Amplifiers. VariTrans A 21000
Standard-Signal Isolation Amplifiers The first standard-signal isolation amplifier with protective separation and broad-range power supply in the 6-mm class. The Task Isolation and conversion of 0... 20
More informationINSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers
2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationProgrammable logic valve control type PLVC 4
Programmable logic valve control type PLVC 4 See also other electronic valve controls/accessory: Type PLVC 2 acc. to D 7845-2 Type PLVC-CAN acc. to D 7845 Z Type CAN-HMI acc. to D 7845 HMI 1. General information
More informationODU MINI-SNAP PC Product Description. ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic
ODU MINI-SNAP PC Product Description ODU MINI-SNAP PC: The Connector with Push-Pull-Locking in Plastic Cylindrical Connectors are generally available with several locking mechanisms: The most frequently
More informationMEASURING AND TESTING INSTRUMENTS
MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at
More informationProduct and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N
Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution
GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationCompact pressure switch for multiple actuators
Comct pressure switch for multiple actuators GW A GW A/.0 Printed in Germany Edition 0.0 Nr. 90 Technical description The GW A pressure switch is a comct pressure switch as r EN 8 for DUNGS multiple actuators.
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationAdjustable Capacitive Prox E2K-C
Adjustable Capacitive Prox Cylindrical Sensor Offers Adjustable Detecting Distance Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More informationDESINA installation technology
DEcentralized Standardized INstAllation technology DESINA describes an extensive concept for the standardization and decentralization of the fluid power and electrical installation of machines and applications.
More informationSystem Components Surge Arrester HAW 261 and HAW 262
Technical Information TI 108F/00/en System Components Surge Arrester and Operating Instructions Part. No. 017166-1000 for power supply side for signal input side (2-wire) (2 and 3-wire) Application The
More informationOperating Instructions
Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationTransistor drive 2c/4c 5A slim power relays
Transistor drive c/c 5A slim power relays NC RELAYS NC Flat type () NC (Plug-in type) RoHS compliant NC Flat type () NC () FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic
More informationPT 2X2-24DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal
More informationProximity sensors SME-8M, for T-slot Technical data Magnetic reed
Function e.g., 3-wire, with cable e.g., 3-wire, with plug Magnetic reed measuring principle Insertable in the slot from above, does not protrude over the cylinder profile Cable clip and inscription labels
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More informationDistance and Position Sensors
Distance and Position Sensors SENSORS FOR DISTANCE AND POSITION Using various measuring techniques, HYDAC offers different distance and position sensors for a wide array of mobile and stationary applications.
More informationHow to Order. Manual override. : Non-locking push style. E: Push-turn locking lever style. Electrical entry
SY000/000/7000 Base Mounted Valve Single Unit 1 SY 2 40 Series SY000 SY000 7 SY7000 L How to Order A/B port size Symbol Post size Applicable series Without subplate Rc(PT) 1 8 01 SY000 With subplate Rc(PT)
More informationLinear Position Transducer HLT 1000-R2
7 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationHIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY
HIGHLY SENSITIVE 1500 V FCC SURGE BREAKDOWN VOLTAGE MINIATURE RELAY DS RELAYS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ FEATURES 1. Breakthrough height of 9.8 mm.386
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationPT 3-PB-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationE2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1
Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the
More informationIB080QM65VA3 Part Number
Inductive Proximity Switch with increased Switching Distance IB080QM65VA3 Part Number Technical Data Inductive Data Switching Distance 8 mm Correction Factors V2A/CuZn/Al 0,93/0,40/0,36 quasi-flush A/B/C/D
More informationBulletin 700-HA Tube Base Relay
Bulletin 700-HA Tube Base Relay Bulletin 700 HA Tube Base Relay 10 A contact rating DPDT, 3PDT Pin-style terminals Standard ON/OFF flag indicator Options: LED, push-to-test and manual override, socket-mounted
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationEC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method
Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available
More informationAI561 Analog Input Module
Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968
More informationProgrammable logic valve control type PLVC 41
Programmable logic valve control type PLVC 41 1. General information The programmable logic valve control of type PLVC 41 is a complete PLC with integrated amplifiers for mobile and stationary hydraulic
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationOptimum sensing capability for LCD manufacturing
SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent
More information