Instruction Manual AC-E75. Ultra-Slim PIEZO 2 x 6 Matrix 500-User Outdoor Secured Access Control Unit. AC-E75 Ultra-Slim Secure Keypad IM Page 1

Size: px
Start display at page:

Download "Instruction Manual AC-E75. Ultra-Slim PIEZO 2 x 6 Matrix 500-User Outdoor Secured Access Control Unit. AC-E75 Ultra-Slim Secure Keypad IM Page 1"

Transcription

1 Instruction Manual AC-E75 Ultra-Slim PIEZO 2 x 6 Matrix 500-User Outdoor Secured Access Control Unit AC-E75 Ultra-Slim Secure Keypad IM Page 1

2

3 Contents Contents...3 Introduction...7 Equipment Provided...7 Additional Equipment Required...8 Technical Specifications...9 Electrical Characteristics...9 Environmental Characteristics...9 Mechanical Characteristics...9 Key Features...10 Installation...11 Mounting the AC-E75 Controller...11 Wiring the AC-E Wiring Diagram # Wiring Diagram # Wiring Diagram # AC-E75 Ultra-Slim Secure Keypad IM Page 3

4 Normal, Secure, & Master Users s of Operation Changing the s of Operation Auxiliary Input Functions Alarms Case and Back Tamper Request to Exit (REX) Function PC-15T Power Supply Unit Programming the AC-E Entering Programming Exiting Programming Changing Lock Strike Code Changing Lock Strike Code Changing the Programming Code Changing the Normal / Secure Code Changing the Normal / Bypass Code and Chime settings Setting Fail Safe/Secure Operation Setting Tamper Siren Time Setting the Lock Strike Release Time AC-E75 Ultra-Slim Secure Keypad IM Page 4

5 Defining the Auxiliary Input...39 Enrolling Primary & Secondary Codes...42 Primary Codes...42 Secondary Codes...42 Enrolling Primary and Secondary Codes...43 Enrolling Primary and Secondary Codes using the Standard Method...43 Enrolling Secondary Codes using the Code Search Method...45 Deleting Primary & Secondary Codes...47 Deleting Primary and Secondary Codes using the Standard Method...47 Deleting Primary and Secondary Codes using the Code Search Method...48 Return to Factory Default Settings...50 Replacing a Lost Programming Code...51 Replacing a Lost Normal / Secure Code...52 PC-15T / PS-A15T/ PS-B15T / PS-E15T / PS- F15T POWER SUPPLY INSTALLATION INSTRUCTIONS...53 INTRODUCTION & KEY FEATURES...53 ELECTRICAL SPECIFICATIONS...54 ENVIRONMENTAL SPECIFICATIONS...55 MECHANICAL SPECIFICATIONS...55 WIRING RECOMMENDATIONS...56 PCB MOUNTING DIMENSIONS...56 AC-E75 Ultra-Slim Secure Keypad IM Page 5

6 PS-15T WITH ENCLOSURES PS-A15T / PS-E15T PS-B15T / PS-F15T Wiring Diagram Limited Lifetime Warranty WARRANTY WARRANTY DURATION WARRANTY COVERAGE EXCLUSIONS AND LIMITATIONS LIMITED LIFETIME WARRANTY TERMS PC15T Warranty Technical Support AC-E75 Ultra-Slim Secure Keypad IM Page 6

7 Introduction The AC-E75 is a vandal-resistant keypad access control unit suitable for external applications. The unit accepts up to 500 users and provides entry via the use of PIN codes. It is designed for high security applications, due to the fact that lock strike output and Request to Exit input are not located directly on the AC-E75, which eliminates the possibility of unauthorized entry to the restricted area. A specific Power Supply Unit, PC-15T, must be used in conjunction with the AC-E75. See page 53 for a detailed description of the PC-15T. Equipment Provided The following is provided as part of every AC-E75 package: AC-E75 Access Control Unit. Installation Kit Installation and Operating Instructions AC-E75 Ultra-Slim Secure Keypad IM Page 7

8 Additional Equipment Required Secured Power Supply PC-15T which connects to the following items: 1) Electric Lock Strike mechanism or a Magnetic Lock device, which implements Fail Safe (Power to Lock) or Fail Secure (Power to Open) functions. 2) Request to Exit (REX) button Normally open type. Switch is closed when pressed. Other Rosslare accessories can be found at Rosslare's Web Site: AC-E75 Ultra-Slim Secure Keypad IM Page 8

9 Technical Specifications Electrical Characteristics Operating Voltage Range: VDC Provided from Secure Power Supply (PC-15T) Maximum Input Current: Standby: Maximum: LEDs 15mA 40mA Two Tri-colored LEDs Communication C1, C2 Open collector 5V terminated Environmental Characteristics Operating Temperature: Operating Humidity: 0 F to 145 F (-18 C to 63 C) 0 to 95% (Non- Condensing) Suitable for outdoor use. (IP 65) Mechanical Characteristics Dimensions: Weight: 6.10"(155mm)L x 1.73"(44mm)W x 0.2"(5mm)D 0.33 lbs (150g) AC-E75 Ultra-Slim Secure Keypad IM Page 9

10 Key Features Here are some of the AC-E75 s key features: Bi-directional secure communication with Secure PC-15T Power Supply Ultra-Slim Flush-mount design on flat surface Built-in piezoelectric keypad for PIN code entry Internal Buzzer Two Status / Programming Interface LED's Three User Levels Normal User Secure User Master User Three s of Operation Normal Bypass Secure "Code Search" feature that helps make maintaining user codes easier Request-to-Exit (REX) signal from PC-15T Built-in Back Tamper Bell feature is available with PC-15T Programmable Lock Strike Release, Siren, and Alarm Delay timers Fully-potted construction for outdoor use AC-E75 Ultra-Slim Secure Keypad IM Page 10

11 Installation Mounting the AC-E75 Controller 1) Before starting, select the location to mount the AC-E75 controller. This location should be at shoulder height. 2) For wall mounting, use the included mounting template as a guide for drilling holes for mounting screws and wiring. For US Gang Box mounting, no hole drilling is necessary. CAUTION! DO NOT DRILL (This will damage the unit) A A 3) Mount the unit onto the Gang Box, feeding the cable though the hole and secure in the screws. It is preferred to use security screws, and a special tool. 4) Wire the controller according the wiring instructions on the following page. AC-E75 Ultra-Slim Secure Keypad IM Page 11

12 Wiring the AC-E75 The controller is supplied with a 17-cm pigtail, having a 6-conductor cable. To wire the Controller, perform the following steps: 1) Prepare the controller cable by cutting the cable jacket back 1¼ inch and strip the wire ½ inch. 2) Splice the controller pigtail wires to the corresponding devices and cover each connection. Refer to the wire color guide provided below and to the wiring diagrams provided following pages. Wire Color Guide RED Color BLACK / Shield WHITE GREEN PURPLE V INPUT Description GROUND C1 - Data C2 - Data Tamper Output BROWN Auxiliary Input 3) Trim and cover all conductors that are not used. AC-E75 Ultra-Slim Secure Keypad IM Page 12

13 Wiring Diagram #1 Wiring diagram and schematic for the AC-E75. AC Mains 16VAC 1.5A 25VA FROM A TRANSFORMER Not provided in PS-E15T and PS-F15T 12V LEADACID BATTERY ROSSLARE PC15-T SPEAKER OUT OUTPUT LED UP TO 7 AH RECOMMENDED +V C1 C2 N.C. N.O. REX. SECURED CONTROLLERLOCK 12VDC +V mA (Red) AC-E75 AC-S73 C1 C2 (Black) (White) (Green) Wiring Diagram #2 Wiring diagram for Monitor and Tamper input to external Alarm system. AC-E75 Ultra-Slim Secure Keypad IM Page 13

14 Wiring Diagram #3 Wiring diagram for Auxiliary signal input to external Alarm system. AC-E75 Ultra-Slim Secure Keypad IM Page 14

15 Normal, Secure, & Master Users The AC-E75 accepts up to 500 users and provides entry via the use of PIN codes. Each user is provided with two code memory slots, Memory Slot 1 (Primary Code) and Memory Slot 2 (Secondary Code). The way in which the two memory slots are programmed determines a user s access level and also determines the way in which the AC-E75 grants access in its three modes of operation. There are three user levels: Normal User A Normal User only has a Primary Code and is only granted access when the AC-E75 is in Normal or Bypass. Secure User A Secure User must have a Primary and Secondary Code programmed; the two codes must not be the same. The Secure User can gain access when the AC-E75 is in any of its three modes of operation. In Normal the Secure User must use their Primary Code to gain entry. In Secure the Secure User must present both their Primary and Secondary Codes in order to gain entry. AC-E75 Ultra-Slim Secure Keypad IM Page 15

16 Master User A Master User must have both Primary and Secondary Codes programmed with the same PIN code. The Master User can gain access during any mode of operation by presenting their PIN code once to the controller. (The Master User is convenient but is less secure than a Secure User.) AC-E75 Ultra-Slim Secure Keypad IM Page 16

17 s of Operation The AC-E75 has three modes of operation: 1) Normal MODE LED is GREEN green Normal is the default mode. In Normal mode the door is locked until a Primary Code is presented to the controller. Special codes such as Lock Strike Code 1 and Lock Strike Code 2 are active in Normal mode. (See pages for more information on the Lock Strike Codes). 2) Bypass MODE LED is ORANGE orange In Bypass, access to the premises is dependent on whether the controller's Lock Strike Relay is programmed for Fail Safe Operation or Fail Secure Operation. When the Lock Strike is programmed for Fail Secure Operation, the door is locked until the doorbell button is pressed. When the Lock Strike is programmed for Fail Safe Operation, the door is constantly unlocked. 3) Secure MODE LED is red RED AC-E75 Ultra-Slim Secure Keypad IM Page 17

18 Only Secure and Master Users can access the premises during the Secured. A Secure User must enter their Primary and Secondary Codes to gain entry. After entering their Primary Code the LED will flash green for 10 seconds, during which the Secondary Code must be entered. A Master User only needs to present their code once to gain entry. AC-E75 Ultra-Slim Secure Keypad IM Page 18

19 Changing the s of Operation Changing from Normal to Secure The default factory setting for the Normal / Secure code is ) Enter the 4-digit GREEN Normal / Secure code LED will flash RED red 2) Press the # key to confirm the mode change. LED is red RED Changing from Secure to Normal The default factory setting for the Normal / Secure code ) Enter the 4-digit RED Normal / Secure code. LED will flash GREEN green 2) Press the # key to confirm the mode change. LED will turn green GREEN AC-E75 Ultra-Slim Secure Keypad IM Page 19

20 Changing from Normal to Bypass See page 35 to create/modify the Normal / Bypass code. 1) Enter the 4 digit GREEN Normal / Bypass code. LED will flash orange ORANGE 2) Press the # key to confirm the mode change. LED will turn orange ORANGE Changing from Bypass to Normal See page 35 to create/modify the Normal / Bypass code. 1) Enter the 4 digit ORANGE Normal / Bypass code. LED will flash GREEN green 2) Press the # key to confirm the mode change. LED will turn green GREEN AC-E75 Ultra-Slim Secure Keypad IM Page 20

21 Auxiliary Input Functions The auxiliary input can be configured for use as one of the following functions: 1) Monitor Input providing a - Forced alarm 2) Monitor Input providing a Ajar alarm 3) Input for toggling between Normal and Secure Access modes 4) LED Control Input to control LED Alarms alarms can be generated by connecting the Auxiliary Input to a Position Switch. Either -Forced or -Ajar conditions are supported, as well as, a configurable delay timer for each alarm type. Only one -alarm is enabled at any one time. AC-E75 Ultra-Slim Secure Keypad IM Page 21

22 Case and Back Tamper If the case of the controller is opened or the controller is removed from the wall, a tamper event is triggered and a coded tamper signal is sent to the PC-15T Power Supply, or other compatible device, which will activate the siren. In addition, another output is opened, which can be connected to another device or alarm system, as necessary. Clearing a tamper event is done by entering a valid Employee or Lock Strike Code that will open the Lock Strike Output in the current mode of operation. For example, while in Secure mode, using the Lock Strike Codes to clear tamper event will not work because the Strike Codes does not work in Secure mode. However, applying a Master Code or Secure Code will clear the tamper event in Secure mode. AC-E75 Ultra-Slim Secure Keypad IM Page 22

23 Request to Exit (REX) Function The REX button is connected to the Power Supply Unit (PC-15T). The REX button must be located inside the premises to be secured and is used to open the door without the use of a PIN code. It is usually located in a convenient location, e.g. inside the door or at a receptionist's desk. The function of the REX button depends on whether the Lock Strike Relay is programmed for Fail Safe Operation or Fail Secure Operation. 1) Fail Secure Operation: From the moment the REX button is pressed, the door will be unlocked until the Lock Strike Release Time has passed. After this time, the door will be locked even if the REX button has not been released. Fail Safe Operation: From the moment the REX button is pressed, the door will be unlocked until the REX button is released, plus the Lock Strike Release Time. In this case the Lock Strike Relay only begins its count down once the REX button has been released. AC-E75 Ultra-Slim Secure Keypad IM Page 23

24 PC-15T Power Supply Unit The PC-15T is designed for use with Rosslare's secured series, stand alone access control units, including AC-E75. It is designed to operate indoors and installed within the premises to be secured. The AC-E75 must be used with PC-15T, which provides its Lock Strike output, Request to Exit (REX) Input and Speaker Functions: Bell and Siren*. Both units communicate through a proprietary Rosslare protocol, which provides a secure link between the controller and the power supply unit. This in turn activates the door unlocking. The PC-15T also functions as the power supply for the AC-E75. * The unit signal from the keypad used for Bell is also used for the door-opened chime. AC-E75 Ultra-Slim Secure Keypad IM Page 24

25 Programming the AC-E75 Programming the AC-E75 is done solely via the unit's keypad driven Programming Menu System. To reach the Programming Menu System the AC-E75 must first be placed into Programming mode. See Entering Programming on page 27 for more information. During the AC-E75's manufacturing process certain codes and settings are preprogrammed. These settings are the called the Default Factory Settings. The table below shows the names of all the AC-E75 Menus. It also shows of all the AC- E75 s default factory codes and settings. AC-E75 Ultra-Slim Secure Keypad IM Page 25

26 Programming Menu Menu Menu Description Number 1 Changing Lock Strike Code 1 2 Changing Lock Strike Code 2 3 Changing Program Code 4 Changing Normal/Secure Code 5 Changing Normal/Bypass Code 6 Changing Release Time Defining Auxiliary Input 7 Enrolling PIN Code 8 Deleting PIN Code 0 Return to Default Factory Setting Factory Settings N/A You will find a complete description and instructions for each of the above menu items on the following pages. AC-E75 Ultra-Slim Secure Keypad IM Page 26

27 Entering Programming 1) Press the # key two times within 2 seconds. LED will turn off LED will turn red 2) Enter your 4-digit Programming Code. If the Programming Code is valid the door LED will turn green and the AC- E75 will be in Programming RED GREEN NOTE: The AC-E75 must be in Normal to enter the Programming mode. The factory default Programming Code is If a Programming Code is not entered within 5 seconds, the AC-E75 will return to Normal mode. AC-E75 Ultra-Slim Secure Keypad IM Page 27

28 Exiting Programming 1) To exit the Programming mode at any time: Press the # key two times within 2 seconds (except for mode 7, where a double-press may be required.) You will hear 3 beeps. The LED will turn off and the LED will return to Normal. 2) Wrong entries may reset the controller back to Normal mode. 3) While in Programming mode if no key is pressed for 1 minute the AC-E75 will exit Programming mode and return to Normal mode. GREEN AC-E75 Ultra-Slim Secure Keypad IM Page 28

29 Changing Lock Strike Code 1 The Lock Strike Code 1 is mainly used as a method to quickly test the Lock Strike Relay during installation. When the first user is added to the controller, the default Lock Strike Code 1 will automatically be deleted. Once the code is programmed again, it will not be deleted with the entry of additional User Codes. 1) Enter Programming GREEN mode 2) Press 1 to enter Menu 1 The LED will turn red 3) Enter the new 4-digit code you wish to set as Lock Strike Code 1. 4) System returns to Normal mode You will hear three beeps RED???? GREEN GREEN NOTE: Lock Strike Code 1 does not function in Secure. AC-E75 Ultra-Slim Secure Keypad IM Page 29

30 Wrong entries will return the controller to Normal. Code 0000 will erase the Lock Strike Code 1. The Default Lock Strike code is AC-E75 Ultra-Slim Secure Keypad IM Page 30

31 Changing Lock Strike Code 2 The Lock Strike Code 2 is mainly used as a method to quickly test the Lock Strike Relay during installation. When the first user is added to the controller, the default Lock Strike Code 2 will automatically be deleted. Once the code is programmed again, it will not be deleted with the entry of additional User Codes. 1) Enter Programming mode 2) Press 2 to enter Menu 2 The LED will turn orange 3) Enter the new 4-digit code you wish to set as Lock Strike Code 2. 4) System returns to Normal mode You will hear three beeps GREEN ORANGE GREEN???? GREEN NOTE: Lock Strike Code 2 does not work in Secure. AC-E75 Ultra-Slim Secure Keypad IM Page 31

32 Wrong entries will return the controller to Normal. Code 0000 will erase the Lock Strike Code 2. The Default Lock Strike code is AC-E75 Ultra-Slim Secure Keypad IM Page 32

33 Changing the Programming Code 5) Enter Programming mode 6) Press 3 to enter Menu 3 The LED will turn green 7) Enter the new 4-digit code you wish to set as Programming Code 8) System returns to Normal mode You will hear three beeps GREEN GREEN GREEN???? GREEN NOTE: Programming Code cannot be erased, i.e. the code 0000 is not valid and will not erase the Programming Code. Default programming code is AC-E75 Ultra-Slim Secure Keypad IM Page 33

34 Changing the Normal / Secure Code 1) Enter Programming mode 2) Press 4 to enter Menu 4 The LED will flash red 3) Enter the new 4-digit code you wish to set as Normal / Secure Code 4) System returns to Normal mode You will hear three beeps GREEN RED GREEN???? GREEN NOTE: Code 0000 will erase the Normal / Secure Code. This code is disabled in case the Auxiliary Input is set to toggle between Normal and Secure access modes. Default Normal/Secure code is AC-E75 Ultra-Slim Secure Keypad IM Page 34

35 Changing the Normal / Bypass Code and Chime settings 1) Enter Programming mode 2) Press 5 to enter Menu 5 The LED will flash orange GREEN ORANGE GREEN 3) Below is a list of the four different ways that the Normal / Bypass Code and Chime can be programmed. a) Disable Bypass - Disable Chime b) Disable Bypass - Enable Chime c) Enable Bypass - Disable Chime d) Enable Bypass - Enable Chime a) Disable Bypass Code - Disable Chime Enter the 4-digit code b) Disable Bypass Code - Enable Chime Enter the 4-digit code c) Enable Bypass Code - Disable Chime Enter any 4-digit code??? 0 ending with 0 AC-E75 Ultra-Slim Secure Keypad IM Page 35

36 d) Enable Bypass Code - Enable Chime Enter any 4-digit code??? 0 not ending with 0 4) System returns to Normal You will hear three beeps The LED will turn off The LED will turn green NOTE: GREEN Code 0000 will erase the Normal / Bypass Code. Default Normal/Bypass code none. The chime is only generated when the Lock Strike Relay is activated due to a valid code entry. AC-E75 Ultra-Slim Secure Keypad IM Page 36

37 Setting Fail Safe/Secure Operation Setting Tamper Siren Time Setting the Lock Strike Release Time 1) Enter Programming mode Do GREEN 2) Press 6 to enter Menu 6 The LED will flash green 3) Construct the 4-digit code using the instructions below: First Digit For Fail Secure Operation the first digit should be 0 For Fail Safe Operation the first digit should be 1 Second Digit Siren Time in minutes (1-9, 0-disabled) Third and Fourth Digit Enter the number of seconds (from 1 to 99) that you want the Lock Strike to be released. Do GREEN GREEN???? AC-E75 Ultra-Slim Secure Keypad IM Page 37

38 For example, 0312 means Fail Secure Operation, a 2-minute Siren, and a 12- second Lock Strike release time. 4) System returns to Normal mode You will hear three beeps NOTE: GREEN Default value is 0004 which corresponds to Fail Secure operation, no siren, and 4- seconds Lock Strike release time. AC-E75 Ultra-Slim Secure Keypad IM Page 38

39 Defining the Auxiliary Input The default auxiliary setting is ) Enter Programming mode 2) Press 6 to enter Menu 6 The LED will flash green 3) Construct the 4-digit using the instructions below: Auxiliary Auxiliary Setting GREEN GREEN GREEN???? Auxiliary In addition to the Lock Strike Relay and Lock Strike REX, the AC-E75 features an Auxiliary Output Relay and an Auxiliary Input. The Auxiliary defines the function of the Auxiliary Input and Output. The Auxiliary also determines if the Auxiliary Output Relay is set for Fail Safe or Fail Secure Operation. AC-E75 Ultra-Slim Secure Keypad IM Page 39

40 Auxiliary Settings Each of the Auxiliary s has a two digit setting that affects how the Auxiliary functions. 4) System returns to Normal GREEN You will hear three beeps The LED will turn off. The LED will turn green The Second digit defines Auxiliary Input function while the Third and Fourth digits may have no meaning or otherwise they define delay times for door monitor functions. Digit 1 Digit 2 Digit 3+4 Auxiliary Input menu Auxiliary Input Function 2 3 Toggle Normal/Secure 2 6 Monitor + Forced Alarm N/A Delay* AC-E75 Ultra-Slim Secure Keypad IM Page 40

41 Digit 1 Digit 2 Digit Monitor + Ajar Alarm 2 8 LED Control RED 2 9 LED Control Green * Alarm Delay 0-99 seconds Delay* N/A N/A AC-E75 Ultra-Slim Secure Keypad IM Page 41

42 Enrolling Primary & Secondary Codes Primary Codes Primary Codes can only be enrolled to an empty User Slot, i.e. a slot where there is no existing Primary Code. Primary Codes must be unique, i.e. one user s Primary Code may not be the same as other users Primary Code. Primary Codes cannot be the same as any system codes, such as the Normal / Secure Code or Lock Strike Code. Users who hold a Primary Code can gain entry only during Normal mode. Secondary Codes Secondary Codes can only be enrolled to User Slot that already has a Primary Code enrolled but no Secondary Code. Secondary Codes do not have to be unique, i.e. multiple users can all hold the same Secondary Code. Secondary Codes cannot be the same as any system codes, such as the Normal / Secure Code or Lock Strike Codes. Users who hold Secondary Codes can gain entry in any of Operation. AC-E75 Ultra-Slim Secure Keypad IM Page 42

43 Enrolling Primary and Secondary Codes There are two methods to enroll Primary and Secondary codes, the Standard Method and the Code Search Method. a. The Standard Method is mainly used when the User Slot number for the user you wish to program is known. You can program both Primary and Secondary Codes using the Standard method. (See Enrolling Primary and Secondary Codes using the Standard Method - page 43.) b. The Code Search Method is mainly used when enrolling a user s Secondary Code and the User Slot Code is unknown. The Code Search method only works if a user s Primary Code is already enrolled but the Secondary Code is not. (See Enrolling Secondary Codes using the Code Search Method - page 45.) Enrolling Primary and Secondary Codes using the Standard Method 1) Enter Programming 2) Press 7 to enter Menu 7 The LED will turn orange GREEN ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 43

44 3) Enter the 3-digit User Slot number between 001 to 500 that you wish to enroll a Primary or Secondary code to. For example, the User Slot 003 represents User #3. 4) If the selected slot has no Primary Code, the LED will flash green, indicating that the controller is ready to accept a Primary Code. If the selected slot already has a Primary Code but no Secondary Code, the LED will flash red, indicating that the controller is ready to accept a??? GREEN ORANGE ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 44 RED Secondary Code. If the selected slot already has a Primary and Secondary Code, you will hear a long beep and the controller will return to Normal.

45 5) Enter the 4-digit PIN that you want to assign as the Primary or Secondary Code for this slot number. If the PIN that is entered is valid the LED will stop flashing and then the controller is ready for you to enter the next 3-digit slot number (refer to step 3) that you want to assign a code to, or press the # key to move to the next slot number (refer to step 4). If you do not wish to continue enrolling codes, press the # key twice and the controller will return to Normal mode. Enrolling Secondary Codes using the Code Search Method The Code Search feature enables you to quickly enroll a Secondary Code to a user who already has a Primary Code. 1) Enter GREEN Programming 2) Press 7 to ORANGE enter Menu 7 The LED will turn orange 3) Enter the 3-digit User Slot number 000 The LED will flash orange ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 45

46 The controller is now waiting for the Primary Code of the User you want to add a Secondary Code to. 4) Enter the 4-digit PIN Code of the Primary Code belonging to the user you want to add a Secondary Code to. The LED will flash red RED If the Primary Code entered is not valid, you will hear a long beep and the AC-E75 will continue to wait for a valid Primary Code. 5) Enter the 4-digit PIN Code to be used as the Secondary Code. If the Secondary Code is valid the controller will beep three times and return to Normal. If the Secondary Code is invalid the controller will sound a long beep and the AC-E75 will continue to wait for a valid Secondary Code to be entered. ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 46

47 Deleting Primary & Secondary Codes There are two methods to delete Primary and Secondary codes: the Standard Method and the Code Search Method. When deleting a User Slot, both the Primary Code and the Secondary code are erased. Deleting Primary and Secondary Codes using the Standard Method 1) Enter Programming GREEN 2) Press 8 to enter RED Menu 8 The LED will turn red 3) Enter the 3-digit User Slot codes you wish to delete. The LED will flash red Indicating the controller is waiting for the Programming Code to confirm the deletion.??? ORANGE RED ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 47

48 If the User Slot is empty you will hear a long beep and the AC-E75 will return to Normal. 4) Enter your Programming Code to confirm the deletion.???? If the Programming Code is valid, you will hear three beeps and the AC-E75 will return to Normal. If the Programming Code is invalid, you will hear a long beep and the AC- E75 will return to Normal. NOTE: It is recommended that a record be kept of added and deleted users so that it will be easier to keep track of which user slots are empty and which user slots are not. Deleting Primary and Secondary Codes using the Code Search Method 1) Enter Programming GREEN 2) Press 8 to enter RED Menu 8 The LED will turn red ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 48

49 3) Enter the 3-digit User Slot number 000 The LED will flash orange ORANGE AC-E75 Ultra-Slim Secure Keypad IM Page 49 RED The controller is now waiting for the Primary Code of the user you want to delete. 4) Enter the 4-digit PIN???? Code of the Primary Code belonging to the user you want to delete. The LED will flash red RED ORANGE 5) Enter your Programming Code to confirm the deletion. If the Programming Code is valid, you will hear three beeps and the AC-E75 will return to Normal. If the Programming Code is invalid, you will hear a long beep and the AC-E75 will return to Normal. NOTE: It is recommended that a record be kept of added and deleted users so that it will be easier to keep track of which user slots are empty and which user slots are not.

50 Return to Factory Default Settings WARNING: You must be very careful before using this command! Doing so will erase the entire memory which includes all User and Special Codes, and return all codes to their factory default settings. 1) Enter Programming GREEN 2) Press 0 to enter Menu 0 RED RED The LED will flash red The LED will flash red 3) Enter your 4-digit Programming Code.???? If the Programming Code is valid, all memory will be erased. You will hear three beeps and the controller will return to Normal. If the Programming Code is invalid you will hear a long beep and the controller will return to Normal without erasing the memory of the controller. AC-E75 Ultra-Slim Secure Keypad IM Page 50

51 Replacing a Lost Programming Code NOTE: The AC-E75 must be in Normal mode otherwise this will not work. Make sure that the LED is green before proceeding. 1) Remove power from the Power Supply Unit (PC-15T). 2) Press the REX button on the Power Supply Unit (PC-15T). 3) Apply power to the unit with REX button pressed. 4) Release the REX button. 5) You now have 15 seconds to program a new Programming code into the Access Control unit using the initial default code 1234, before the controller reverts to the existing code. AC-E75 Ultra-Slim Secure Keypad IM Page 51

52 Replacing a Lost Normal / Secure Code NOTE: The AC-E75 must be in Secure otherwise this will not work. Make sure that the LED is red before proceeding. 1) Remove power from the Power Supply Unit (PC-15T). 2) Press the REX Button on the Power Supply Unit (PC-15T). 3) Apply power to the unit with the REX button pressed. 4) Release the REX Button. 5) You now have 15 seconds to program a new Normal / Secure code into the Access Control unit using the initial default code 3838, before the controller reverts to the existing code. AC-E75 Ultra-Slim Secure Keypad IM Page 52

53 PC-15T / PS-A15T/ PS-B15T / PS-E15T / PS-F15T POWER SUPPLY INSTALLATION INSTRUCTIONS INTRODUCTION & KEY FEATURES The PC-15T Power Supply is designed for use with all Rosslare secured series standalone access control units. The PC-15T contains two power supplies. One power supply is for the lock strike, the other is for the access control unit (ACU). The lock strike is attached directly to the power supply. This design isolates the lock from the ACU securing the functionality of lock even if the ACU is tampered with. When a valid code is entered at the ACU, the ACU communicates to the power supply using a Rosslare proprietary protocol sending a command to activate the lock. Similarly, the Release to Exit (REX) button is attached directly to the power supply, when the REX is pushed the power supply will communicate the REX request to the ACU and then the ACU will communicate back to the power supply to activate the lock strike. If the data line between the ACU and the power supply is cut, the system will immediately detect that the data line has AC-E75 Ultra-Slim Secure Keypad IM Page 53

54 been tampered with, and will generate a siren for one minute. A sealed lead acid battery charger is built-in to provide back-up power for the ACU and the Lock Strike. The PC-15T can also power an external speaker that is controlled by the ACU to annunciate Belland Siren tones. The PC-15T is also available in two steel enclosures. For more details on the models with enclosures, PS-A15T, PS-B15T, PS- E15T, and PS-F15 see page 57. ELECTRICAL SPECIFICATIONS AC Input: 16 ~ 18 VAC (1.5 A, 25 VA) DC Battery Charger: 12V DC Lead Acid Battery Up to 7AH recommended DC Input wired to backup battery terminals: VDC Battery current draw depends on attached devices Lock Strike Output and Power Supply: 5 A Relay SPDT connection available via terminal blocks 12 VDC, constant voltage AC-E75 Ultra-Slim Secure Keypad IM Page 54

55 1.2 A current limit Controller Power Supply: 12 VDC, constant voltage 300 ma current limit Communications: Rosslare proprietary protocol Power LED & Speaker Output: Power LED indicator. 8 OHM, 0.25 W (Minimum) For bell, chime and siren alerts ENVIRONMENTAL SPECIFICATIONS Operating Temperature: -10 C to 70 C (14 F to 158 F) Operating Humidity: 0 to 95% (Non-Condensing) MECHANICAL SPECIFICATIONS Weight: 59 grams (0.11 lbs) Dimensions: 77mm (3.0 ) Length 57mm (2.2 ) Width 33mm (1.3 ) Depth AC-E75 Ultra-Slim Secure Keypad IM Page 55

56 WIRING RECOMMENDATIONS Maximum distance between the Controller and the PC-15T is 50m (150ft). Lock wiring should be 20 Gage Communication wiring (C1 & C2) should be twisted Pair, 22 Gage, shielded or unshielded. PCB MOUNTING DIMENSIONS Dimensions for PCB mounting holes are provided below. 46mm (1.8 ) 66mm (2.6 ) AC-E75 Ultra-Slim Secure Keypad IM Page 56

57 PS-15T WITH ENCLOSURES PS-A15T / PS-E15T The PS-A15T and PS-E15T enclosures include a built-in speaker and enough room for a CE or UL approved transformer. PS-A15T The PS-A15T comes with a built-in CE approved transformer. That is Class II Rated (Double insulated) and contains thermal fuse protection. Max: 125 C, 1A. See transformer specifications below: Input: Output: Certifications: Compliance: 230 VAC ~ 50Hz, 0.14 A 16 VAC ~ 1.5A, 25 VA CE A1:1998 EN :1997 EN :1997 AC-E75 Ultra-Slim Secure Keypad IM Page 57

58 PS-E15T The PS-E15T is shipped without a transformer and is designed to be powered from an external transformer. When sold in the United States a UL approved transformer is recommended. The enclosure weight and dimensions are provided below: Dimensions: 182mm (7.2 ) Length 80mm (3.1 ) Width 68mm (2.7 ) Depth Weight: 1.24Kg (2.7lbs) PS-A15T 0.63Kg (1.3lbs) PS-E15T PS-B15T / PS-F15T The PS-B15T and PS-F15T enclosures include a built-in speaker and enough room for a CE or UL approved transformer as well as a lead acid backup battery (up-to 7 AH). AC-E75 Ultra-Slim Secure Keypad IM Page 58

59 PS-B15T The PS-B15T comes with a built-in CE approved transformer. That is Class II Rated (double insulated) and contains thermal fuse protection. Max: 125 C, 1A. See transformer specifications below: Input: Output: Certifications: Compliance: 230 VAC ~ 50Hz, 0.14 A 16 VAC ~ 1.5A, 25 VA CE A1:1998 EN :1997 EN :1997 PS-F15T The PS-F15T is shipped without a transformer and is designed to be powered from an external transformer. When sold in the United States a UL approved transformer is recommended. The enclosure weight and dimensions are provided below: Dimensions: 205mm (8.1 ) Length 200mm (7.9 ) Width 82mm (3.2 ) Depth Weight: 1.24Kg (2.7lbs) PS-B15T 0.63Kg (1.3lbs) PS-F15T AC-E75 Ultra-Slim Secure Keypad IM Page 59

60 Wiring Diagram Wiring Diagram and schematic for the PC- 15T, PS-A15T, PS-B15T, PS-E15T, PS- F15T are provided below: 16V AC (1.5A, 25VA) AC Mains FROM A TRANSFORMER Not provided in PS-E15T and PS-F15T 12V LEAD ACID BATTERY VIN +BAT 16VAC 12VDC ROSSLARE PC-15T SPEAKER OUT OUTPUT LED UP TO 7 AH RECOMMENDED +V C1 C2 N.C. N.O. REX. SECURED CONTROLLER LOCK 12VDC OP-PSA12-V4 N.C. N.O. +V (12 300mA) COMPATIBLE ROSSLARE CONTROLLER C1 C2 AC-E75 Ultra-Slim Secure Keypad IM Page 60

61 Limited Lifetime Warranty ROSSLARE ENTERPRISES LIMITED S (Rosslare) LIMITED LIFETIME WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's LIMITED LIFETIME WARRANTY is subject to the following conditions: WARRANTY Warranty of Rosslare's products extends to the original purchaser of the Rosslare product and is not transferable. WARRANTY DURATION Rosslare warrants this product against defects in material and/or workmanship for the life of the product from the date of original purchase to the original purchaser. WARRANTY COVERAGE Rosslare will repair or replace, at its option, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be made for labor or parts with respect to defects covered by this warranty, provided that Rosslare does the work or a Rosslare authorized service center. This warranty does not cover expenses incurred in the transportation, removal or reinstallation of the product, whether or not proven defective. Replacement or repairs furnished under this warranty are subject to the same terms and conditions of the original warranty. AC-E75 Ultra-Slim Secure Keypad IM Page 61

62 EXCLUSIONS AND LIMITATIONS Specifically excluded from this warranty are failures caused by abuse, neglect, misuse, improper operation, normal wear, accident, improper maintenance or modification. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages. LIMITED LIFETIME WARRANTY TERMS The terms of this warranty may not be varied by any person, whether or not purporting to represent or act on behalf of Rosslare. This warranty represents the full extent of Rosslare's responsibility. Repair, replacement, or refund of the original purchase price, of the product is the exclusive remedy. This limited lifetime warranty is provided in lieu of all other warranties. All other warranties expressed or implied, including without limitation, implied warranties of merchantability and fitness for a particular purpose, are specifically excluded. In no event shall Rosslare be liable for damages in excess of the purchase price of the product, or for any other incidental, consequential or special damages, including but not limited to loss of use, loss of time, commercial loss, inconvenience, and loss of profits, arising from the installation, use, or inability to use such product, to the fullest extent that any such loss or damage may be disclaimed by law. This warranty shall become null and void in AC-E75 Ultra-Slim Secure Keypad IM Page 62

63 the event of a violation of the provisions of this limited warranty. PC15T Warranty The Manufacturer's warranty on this product is for a period of two years from the date of manufacture against defects in materials and workmanship. Manufacturer's warranty hereunder is limited to repair or replacement, at the manufacturer's sole option, if the product is found to be defective in normal use during the warranty period. The warranty is given in favor of the original purchase only. Subject to the above warranty, manufacturer's liability and that of it's distributors, re-sellers and agents and is wholly limited to the original purchase price and no payment will be made for related or consequential loss including but not limited to labor costs incurred in inspection, replacement or repair of defective products. This warranty is given expressly and in place of all other expressed or implied warranties of merchantability and fitness for a particular purpose and this warranty is the only warranty made by the manufacturer. No agent, representatives or employee of the manufacturer has the authority to waive, alter or add to the printed provisions of this warranty, to make representation of warranty not contained herein or to extend this warranty to anyone other than the original purchaser of the product. The PC-15T, PS-A15T, PS-B15T, PS-E15T, and PS- F15T are guaranteed against defects in workmanship and material for a period of 24 (Twenty Four) months from date of purchase. Return the faulty product with a dated proof of purchase to your dealer for replacement. AC-E75 Ultra-Slim Secure Keypad IM Page 63

64 Technical Support International Web Site: Asia, Australia, & Middle East: Rosslare Enterprises Ltd Wing Fat Industrial Bldg., 12 Wang Tai Road, Kowloon Bay, Hong Kong Tel: (852) Fax: (852) Europe & Russia Rosslare Israel, Ltd. HaMelecha 22, Rosh HaAyin, 48091, Israel Tel: (972) Fax: (972) support@rosslaresecurity.com United States and Canada: Rosslare NAPDC 200 East Howard Street, Suite 238, Des Plaines, IL USA Tel: (847) Fax: (847) support@rosslaresecurity.com AC-E75 Ultra-Slim Secure Keypad IM Page 64

65 South America: Rosslare Latin America Pringles 878, 1640 Martinez, Buenos Aires, Argentina Tel: (54) Fax: (54) / 9J-RSP-069 AC-E75 Ultra-Slim Secure Keypad IM Page 65

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT.  07/04 INSTRUCTION MANUAL 1 2 3 4 5 6 7 8 9 0 # PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT www.rosslaresecurity.com 0706-0960050-00 07/04 Contents INTRODUCTION 4 Technical Specifications 5 Key Features 6 INSTALLATION

More information

SA-59. GSM Communicator. Installation Manual

SA-59. GSM Communicator. Installation Manual SA-59 GSM Communicator Installation Manual September 2009 Table of Contents Table of Contents 1. Introduction... 3 1.1 Overview... 3 1.2 Main Features... 4 2. Technical Specifications... 5 3. Installation...

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual AC-015 Single- Access Control Programmer Hardware Installation and Programming Manual Copyright 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to

More information

Long range Multi Reader AY-Z12A Installation Guide

Long range Multi Reader AY-Z12A Installation Guide Long range Multi Reader AY-Z12A Installation Guide December 2010 Table of Contents Table of Contents 1. Introduction... 3 2. Technical Specifications... 4 3. Installation... 5 3.1 The Installation Kit...

More information

AC-S/T43 Family Anti-Vandal Piezoelectric PIN Standalone Controller Installation and Programming Manual

AC-S/T43 Family Anti-Vandal Piezoelectric PIN Standalone Controller Installation and Programming Manual AC-S/T43 Family Anti-Vandal Piezoelectric PIN Standalone Controller Installation and Programming Manual AC-S43 AC-T43 Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained

More information

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01 ROSSLARE MODE 1 2 DOOR 3 4 5 6 7 8 9 0 # AC-115 Hardware Installation and User s Guide 10/01 ROSSLARE Hardware Installation and User s Guide for the AC-115 Access Control System MODE 1 2 DOOR 3 4 5 6 7

More information

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44 AC-Q4x Family Vandal Resistant Stand-Alone controllers Instruction Manual ls: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44 December 2006 Table of Contents Table of Contents 1. General Information...

More information

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual ls: AC-Q41H/HB AC-Q41HP AC-Q41SB AC-Q42H/HB AC-Q42HP AC-Q42SB AC-Q44 Copyright 2014 by Rosslare. All rights reserved.

More information

AYC-Ex5/T65 Family Convertible Backlit Proximity & PIN Readers/Controllers Installation and Programming Manual

AYC-Ex5/T65 Family Convertible Backlit Proximity & PIN Readers/Controllers Installation and Programming Manual AYC-Ex5/T65 Family Convertible Backlit Proximity & PIN Readers/Controllers Installation and Programming Manual Ex5 Models: AYC-E55 AYC-E65BB AYC-E65BG AYC-E65BW T65 Models: AYC-T65B AYC-T65N AYC-Ex5 AYC-T65

More information

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual AYC-F60 AYC-G60 AYC-M60 Copyright 2013 by Rosslare. All rights reserved.

More information

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide AC-225 Advanced Scalable Networked Access Controller Hardware Installation and User Guide July 2007 Table of Contents Table of Contents 1. Introduction... 3 1.1 Features...5 1.2 VeriTrax AS-225...5 2.

More information

2012 December. AY-Q64 Anti-Vandal PIN & Proximity Reader Installation and Programming Manual

2012 December. AY-Q64 Anti-Vandal PIN & Proximity Reader Installation and Programming Manual 2012 December AY-Q64 Anti-Vandal PIN & Proximity Reader Installation and ming Manual Copyright 2012 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to

More information

AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual AYC-E60 AYC-Q60 AYC-T60 Copyright 2013 by Rosslare. All rights reserved.

More information

7612 Programming Instructions

7612 Programming Instructions 7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards 7612 is a vandal resistant proximity card and keypad access control

More information

IBA-7612 Programming Instructions

IBA-7612 Programming Instructions IBA-7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards IBA-7612 is a vandal resistant proximity card and keypad access

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

AY-Bx660 Family Full Fingerprint Match-on-Card Readers Installation Manual. Models: AY-B1660 AY-B2660

AY-Bx660 Family Full Fingerprint Match-on-Card Readers Installation Manual. Models: AY-B1660 AY-B2660 AY-Bx660 Family Full Fingerprint Match-on-Card Readers Installation Manual Models: AY-B1660 AY-B2660 AY-B1660 AY-B2660 Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

AY-V64B Multi-Reader Installation and Programming Manual

AY-V64B Multi-Reader Installation and Programming Manual AY-V64B Multi-Reader Installation and ming Manual Copyright 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

Wireless Doorphone Intercom

Wireless Doorphone Intercom Security Made Smarter Wireless Doorphone Intercom EN INSTRUCTION MANUAL DOORBELL OVERVIEW MICROPHONE LEDS CAMERA LENS LIGHT SENSOR Detects ambient light and turns on the LEDS to provide clear color night

More information

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads User Operation for the SK--SQ Note: n n n nindicates. Using the User Codes: A. User codes operate the door (4-8 digits long). the inhibit code. Note: u u u uindicates Press u u u u the user code. B. The

More information

AC-225x Family Advanced Scalable Networked Access Controller Hardware Installation Manual

AC-225x Family Advanced Scalable Networked Access Controller Hardware Installation Manual 2013 February AC-225x Family Advanced Scalable Networked Access Controller Hardware Installation Manual Models: AC-225E, AC-225IPU AC-225U, AC-225IPU AC-225L, AC-225IPL AC-225 PCBA, AC-225IP PCBA Copyright

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards. Installation And Operation BASIC A/B SWITCHES K-AB-D25 K-AB-M34 SCOPE OF THIS DOCUMENT This document covers the following models: K-AB-D25 K-AB-D25-R K-AB-M34 K-AB-M34-R For the purposes of clarity, all

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

Agility 2-Way Wireless Slim Keypad

Agility 2-Way Wireless Slim Keypad Agility 2-Way Wireless Slim Keypad Models: : RW132KL1, RW132KL1P Instruction Manual Agility 2-Way Wireless Slim Outdoor Keypad Table of Contents INTRODUCTION 3 MAIN FEATURES 3 COMMUNICATION SETUP 3 MOUNTING

More information

232iLM Keypad Installation and Programming Instructions

232iLM Keypad Installation and Programming Instructions 232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2

More information

SK-1011-SQ Digital Access Keypad with 5A Relay Output

SK-1011-SQ Digital Access Keypad with 5A Relay Output User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u

More information

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1 AXS-100 I/O Expander 1. INTRODUCTION The is an input / output expander for the AXS-100 access control panel. It contains eight analog inputs and eight dry contact relays output. Up to four boards may be

More information

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR

More information

AYC-x6355 Family CSN SELECT Smart Card Readers/Controllers Installation and User Manual. Models: AYC-H6355 AYC-M6355

AYC-x6355 Family CSN SELECT Smart Card Readers/Controllers Installation and User Manual. Models: AYC-H6355 AYC-M6355 AYC-x6355 Family CSN SELECT Smart Card Readers/Controllers Installation and User Manual Models: AYC-H6355 AYC-M6355 AYC-H6355 AYC-M6355 Copyright 2016 by Rosslare. All rights reserved. This manual and

More information

Proximity Card and Pin Reader Installation Manual

Proximity Card and Pin Reader Installation Manual Multi Prox Proximity Card and Pin Reader Installation Manual PUBLICATION INFORMATION 60A9 - Draft Release Version 0.1.2 71D0 - Version 1.0.5 CONTENTS Introduction... 1 Legend... 2 Terminology... 2 Mounting...

More information

User Guide. Control Box. RoscoLED TM.

User Guide. Control Box. RoscoLED TM. RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260

More information

Digital Electronic Lock OWNER S MANUAL

Digital Electronic Lock OWNER S MANUAL CAL-ROYAL CR3000 Digital Electronic Lock OWNER S MANUAL THANK YOU for purchasing CAL-ROYAL CR 3000 Digital Lock. Your new CAL-ROYAL CR3000 Digital Lock advanced features include: 1 Master Code for entry

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com K-PROX Series INSTALLATION & INSTRUCTION MANUAL K-Prox Series Self-Contained Keyless Entry System All rights reserved. No part of this documentation may be reproduced in any form, without prior written

More information

VIP-480AL IP One-Way Horn

VIP-480AL IP One-Way Horn Issue 1 VIP-480AL IP One-Way Horn Issue 1 INTRODUCTION The VIP-480AL IP One-way Horn provides for one-way communication when used in a Valcom VoIP based intercom/paging system. SPECIFICATIONS Access Methods

More information

SpeedVault Model SV 500 User Manual

SpeedVault Model SV 500 User Manual SpeedVault Model SV 500 User Manual Patented Rev 1 (10/11) Firearm Safety WARNING: The SpeedVault safe or any other firearm storage device cannot take the place of other safety procedures including advising

More information

FW2 MERLIN PRO Manual ==============================

FW2 MERLIN PRO Manual ============================== FW2 MERLIN PRO Manual ============================== PROGRAMMABLE STAND ALONE 2WAY WIRELESS TRANSCEIVER Installation and Programming Guide WWW.THECROWGROUP.COM ELECTRONIC ENGINEERING LTD. P/N 7106452 Rev.

More information

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control Remote Control for Inverter RC-300 Owner's Manual Please read this manual BEFORE operating your RC-300 Remote Control OWNER'S MANUAL Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads Quick Reference Guide. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must be pressed also if the keypad is in manual-entry mode. Press u u u u Note: u

More information

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA PD10 Pulse Divider Instructions PROUDLY MADE IN THE USA ISO 001:200 Certified Company General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Installation Mounting...Page

More information

DP-222Q Color Video Door Phone Manual

DP-222Q Color Video Door Phone Manual DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect a secondary * Simple 2-wire connection

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual Screen image simulated. * has four LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from

More information

Electronic Code Lock. SL2000E v1.1

Electronic Code Lock. SL2000E v1.1 SL2000E v1.1 EN Rev.C.doc 1/29/2008 Electronic Code Lock SL2000E v1.1 Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming

More information

AC-215. Single and Double Door Access Control Unit Hardware Installation Guide

AC-215. Single and Double Door Access Control Unit Hardware Installation Guide AC-215 Single and Double Door Access Control Unit June 2006 Copyright and Version Number Information in this document, including URL and other Internet Web site references, is subject to change without

More information

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad ipad Charge & Sync Cart Model MCC2 ipad Cart ipad Is a Registered Trademark of Apple Inc. 430-MCC2-User Manual-010 1. ipad Cart Specifications MCC2 Mobile Charge & Sync Cart Extra Drawer Reserved space

More information

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller Kramer Electronics, Ltd. USER MANUAL Model: RC-52N Room Controller Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your RC-52N 3 4.1 The RC-52N Front Panel 3 4.2 The RC-52N Rear Panel

More information

232iLM Keypad Installation & Programming Instructions

232iLM Keypad Installation & Programming Instructions 232iLM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6-1/2 L x

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

LPG STM 94442A User s Manual

LPG STM 94442A User s Manual 1 LPG STM 94442A User s Manual This Manual belongs to: Company: 3 Table of Contents Features....... 4 Hardware Installation...5 Monitor Mounting Dimensions.....7 Monitor Specifications...8 Sender Specifications.....9

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option KB/HB-Series INSTALLATION INSTRUCTIONS EB7-4W Module Installation Clear-Com s EB7-4W 4-Wire Option module can be added to the KB-702, KB- 702GM, KB-701, and HB-702 products. This option allows the speaker

More information

PSA200 User s Manual

PSA200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

ASCL1 / ASCL2 CarLink Guide for Android Users

ASCL1 / ASCL2 CarLink Guide for Android Users ASCL1 / ASCL2 CarLink Guide for Android Users 2012 Audiovox Electronics Corporation. All rights reserved. CarLink Guide for Android Users New Account Creation After having CarLink installed, follow the

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates

More information

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller Kramer Electronics, Ltd. USER MANUAL Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 2 4 Your RC-2C/RC-2

More information

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

MUTING VOLUME CONTROL CONNECTION TERMINAL

MUTING VOLUME CONTROL CONNECTION TERMINAL INSTALLATION & USER GUIDE For Parallel Signal Distribution to Multiple Muting Volume Controls MUTING VOLUME CONTROL CONNECTION TERMINAL V-T4M V-T4M MUTING VOLUME CONTROL CONNECTION TERMINAL TABLE OF CONTENTS

More information

MPP200 User s Manual

MPP200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN Copyright 2018 by Rosslare. All rights reserved. This

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

DP-222Q Color Video Door Phone Manual

DP-222Q Color Video Door Phone Manual DP-222Q Color Video Door Phone Manual * has 6 LEDs for nighttime operation Remotely and securely talk to visitors and unlock doors, gates, etc. from the Easily connect an secondary * Simple 2-wire connection

More information

Messager USB w/ Night Answer

Messager USB w/ Night Answer Messager USB w/ Night Answer Digital Messaging System Installation & Users Guide Attention! Some USB drives have indicator LEDs - These LEDs may blink slow, fast, or may stay solid during playback. Any

More information

CS-CCT Configuration Card Tool for the DR-6255 Software Manual

CS-CCT Configuration Card Tool for the DR-6255 Software Manual CS-CCT Configuration Card Tool for the DR-6255 Software Manual Copyright 2017 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved. ASCL1 / ASCL2 CarLink Guide for BlackBerry Users 2012 Audiovox Electronics Corporation. All rights reserved. CarLink Guide for BlackBerry Users New Account Creation After having CarLink installed, follow

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su StorCase Technology Rhino JR FJR110 1-Bay External FireWire 800/USB 2 0-to-IDE Expansion Chassis User's Guide Part No D89-0000-0249 A04 July 2005 StorCase Technology, Inc 17600 Newhope Street Fountain

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

87421/22A Power Supply. Operating and Service Manual

87421/22A Power Supply. Operating and Service Manual 87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to

More information

I/O Expansion Box Installation & Operator s Instruction Manual

I/O Expansion Box Installation & Operator s Instruction Manual I/O Expansion Box Installation & Operator s Instruction Manual May 2004 CTB Inc. Warranty I/O Expansion Box CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V PagePac Issue 3 by PAGEPAC PLUS ZONE EXPANSION UNIT V-5335100 INTRODUCTION The Zone Expansion Unit (ZEU) provides up to 16 zones of audio output (including talkback), contact closure outputs or inputs.

More information

MD-N32 Serial to Ethernet Gateway Installation and Operating Guide

MD-N32 Serial to Ethernet Gateway Installation and Operating Guide MD-N32 Serial to Ethernet Gateway Installation and Operating Guide Copyright 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES

More information

FNet Repeater Installation & Operator s Instruction Manual

FNet Repeater Installation & Operator s Instruction Manual FNet Repeater Installation & Operator s Instruction Manual October 2004 CTB Inc. Warranty FNet Repeater CTB Inc. Warranty CTB Inc. warrants each new Chore-Tronics product manufactured by it to be free

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models: AC-225x-B Series Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual Models: AC-225-Bx AC-225-DIN AC-225IP-Bx AC-225IP-DIN Copyright 2018 by Rosslare. All rights reserved. This

More information

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision: INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console ACC1-25 (Part # 63971-002) ECM Motors Revision: 10.01.13 Page: 2 of 11 Table of Contents Safety Precautions...3 Overview...3 Specifications...4

More information

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

AK-21. Digital Keyless Entry System. Installation and Programming Instructions AK-2 Digital Keyless Entry System Installation and Programming Instructions (760) 8-7000 USA & Canada (800) 2-587 & (800) 92-02 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS COMPONENT LOCATIONS.......................................

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

EZ Bridge B 100mW Product Guide

EZ Bridge B 100mW Product Guide EZ Bridge 802.11B 100mW Product Guide I. Introduction Section - Product Information Product Name: EZ Bridge Model: 802.11B 100mW Item Number: 11-207 (PCB Kit) and 11-208 (NEMA4 Box) II. Technical Specs

More information

Wireless Access Control Door Interface Installation Manual MD-W11F

Wireless Access Control Door Interface Installation Manual MD-W11F MD-W11 Wireless Access Control Door Interface Installation Manual MD-W11N MD-W11F MD-W11BP Copyright 2014 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B PMDX-103 Parallel Port Isolator Board User s Manual Date: 20 February 2007 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

AirPro Surveyor 2 Manual

AirPro Surveyor 2 Manual AirPro Surveyor 2 Manual AirPro Surveyor Specifications Table of Contents Size 3/8 x 7 1/2 x 4 3/8 Weight 4.6 lbs. 2094 g Dynamic Range 1-1000 ml/min. total flow/constant flow Flow Capacity (8 Hrs.) 1000

More information

Introduction. 1. RF Module

Introduction. 1. RF Module Introduction RISCO Groupʹs 2 Way Wireless I/O & X10 Module is an extension module enabling wired devices to be connected to the Agility Wireless system. The Wireless I/O Module supports 4 hardwired zones,

More information