Interfacing with the Biacore instrument

Size: px
Start display at page:

Download "Interfacing with the Biacore instrument"

Transcription

1 Interfacing with the Biacore instrument Different ways of interfacing with the instrument Manual run Wizards Method Builder methods 2 1

2 Manual Run 3 Application Wizards Guides you through each step in the analysis 4 2

3 Method Builder Method Builder - Concept Designed for maximum flexibility Built in support for evaluation Integrated assay knowledge 6 3

4 Method Builder Support Provided Small molecules» Solvent correction» Extra wash procedures Affinity in Solution Buffer change Adaptivity» If Then commands 7 Methods 1(2) Assays are built up step by step in Methods» Possible to save, share and re-use methods 3 approaches to creating methods:» Create Methods from wizards» Start with a Biacore Method» Create your own Method 8 4

5 Methods 2(2) Pre-defined Biacore Methods» LMW screen» LMW kinetics» Kinetics heterogeneous analyte» Affinity in solution» NTA kinetics» L1 liposome capture 9 Workflow Overview General settings Define method Define run settings and start the run Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Rack Positions Save Method (.method) Save Run (.blr) 10 5

6 Define Method 1(3) Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Rack Positions Save Method (.method) Save Run (.blr) 11 Define Method 2(3) Assay Steps» Define the purpose of assay components (e.g. start-up, sample, control sample)» Assay steps can be repeated or recurrent» Recurrent for e.g. control samples every 10 th sample Cycle Types» Define the injection sequence for a cycle using commands» Set parameters for each injection» Parameters can be defined as variables Connect Cycle Type to Assay Step 12 6

7 Define Method 3(3) Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Variable definition In method At run time Some in method, others at run time Rack Positions Save Method (.method) Save Run (.blr) 13 Setup Run Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Define run settings and start the run Rack Positions Save Method (.method) Save Run (.blr) 14 7

8 More about Method Builder Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Create method from Kinetics wizard template Rack Positions 15 Overview Provides a summary of the method (settings cannot be changed here) Left panel shows assay steps Right panel shows settings and cycle type definition for the selected assay step 16 8

9 General Settings At start: Concentration unit At start: Data collection rate At start: Sample compartment temperature After run: Analysis temperature Detection (single, dual or multi)» Affects which flow paths will be available for each injection command 17 Assay Steps Determines the main structure of the method Steps at the top level are executed in the order given Nested steps (marked with an arrow) are executed within the step they are placed 18 9

10 Cycle Types Injection parameters are set (contact time, type of injection, etc) Report points may be added or altered Variables may be added or altered For example, one cycle type can include the commands Sample1 and Regeneration1 19 Connect Cycle Type to Assay Step Performed in Assay Steps 20 10

11 Sample & Assay Setup Determine whether variables are defined in method, at run time, or a mixture of these 21 Verification Checks that the method is correctly and completely defined A method that fails verification can be saved but not run Verification may fail because parameters are missing or the method construction is invalid 22 11

12 Setup Run - Detection Set the flow path for the detection Only choose flow path consistent with Detection setting for the method 23 Setup Run - Variables Assign values to variables that were not defined in method (for each assay step) 24 12

13 Setup Run Cycle Run List Complete summary of the cycles in the run 25 Setup Run System Preparations Choose preparation steps to be executed before the run Temperature settings can only be defined in method 26 13

14 Setup Run Rack Positions Displays the sample and reagent positioning 27 Setup Run Prepare Run Protocol Allows you to enter a run protocol with instructions A general protocol is suggested 28 14

15 Method Builder - Summary Software tool for user-defined methods» Maximum flexibility» Support features not available in wizards» Built-in evaluation support» Biacore Methods provides user-guidance 29 15

GE Healthcare. Biacore Instrument Handbook

GE Healthcare. Biacore Instrument Handbook GE Healthcare Biacore 3000 Instrument Handbook Contents 1 Introduction 1.1 Biomolecular interaction analysis... 9 1.2 Safety information... 10 1.3 Conformance with standards... 11 2 Description 2.1 Biacore

More information

EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide

EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide This guide describes how to install, configure, and use the Thermo EASY-nLC Virtual Instrument (VI) software with the Thermo Xcalibur

More information

Sciex QTrap Operational Steps for Trained Personnel

Sciex QTrap Operational Steps for Trained Personnel Sciex 6500+ QTrap Operational Steps for Trained Personnel Last Updated 09172017 1. If any of the following instructions does not make sense to you or was not covered during your hand-on training, stop

More information

INSTRUMENT HANDBOOK. Biacore 2000

INSTRUMENT HANDBOOK. Biacore 2000 INSTRUMENT HANDBOOK Biacore 2000 BIACORE 2000 Instrument Handbook.ERYEV] &-%'36) -RWXVYQIRX,ERHFSSO.ERYEV]ZIVWMSR%( 'ST]VMKLX &MEGSVI%& %PPVMKLXWVIWIVZIH2STEVXWSJXLMWTYFPMGEXMSRQE]FIVITVSHYGIHSVWXSVIHMRE

More information

BIAevaluation Software Handbook

BIAevaluation Software Handbook BIAevaluation Software Handbook version 3.0 Things should be made as simple as possible, but no simpler Einstein Edition July 1997 BIAevaluation 3.0 Software Handbook, edition July 1997 (version AC) Copyright

More information

Wave User s Guide. Contents

Wave User s Guide. Contents XF e Wave User Guide Contents Chapter 1: Designing Your Assay... 6 Overview of the Process: Design, Run, and Analyze... 6 Step 1: Design your assay... 6 Step 2: Run your assay... 6 To run a design created

More information

Gen5 & Gen5 Secure User's Guide

Gen5 & Gen5 Secure User's Guide Gen5 & Gen5 Secure User's Guide Microplate Data Collection & Analysis Software BioTek Instruments, Inc. March 2007 2006-2007 PN 5321001 Revision C Chapter 3 Essential Concepts This section reveals the

More information

Reference Guide for the Value Assignment Web v

Reference Guide for the Value Assignment Web v Reference Guide for the Value Assignment Web v 1.02.01 Bio-Rad Laboratories 9500 Jeronimo Road Irvine, CA 92618 Copyright 2008 Contents Introduction to the Value Assignment Web 1 Benefits of the Value

More information

Electrophoresis File Run Summary

Electrophoresis File Run Summary 2100 expert DE72901273_2016-08-05_07-04-39.xad Page 1 of 8 Electrophoresis File Run Summary Instrument Information: Instrument Name: DE72901273 Firmware: C.01.069 Serial#: Assay Information: Assay Origin

More information

Validation Sample Set Generator

Validation Sample Set Generator Validation Sample Set Generator General Information This tool is an example program which demonstrates some capabilities of the Empower Toolkit. It was not created using Waters Software Development Lifecycle.

More information

Getting Good Data with xponent Software for the Luminex MAGPIX, Luminex 100/200, and FLEXMAP 3D Systems

Getting Good Data with xponent Software for the Luminex MAGPIX, Luminex 100/200, and FLEXMAP 3D Systems Getting Good Data with xponent Software for the Luminex MAGPIX, Luminex 100/200, and FLEXMAP 3D Systems FLEXMAP 3D MAGPIX Luminex 100/200 xponent is a modular, flexible software package for control of

More information

Automating HPLC Analytical Methods Development

Automating HPLC Analytical Methods Development Automating HPLC Analytical Methods Development By Graham Shelver, Varian Inc, Walnut Creek, CA and Richard Verseput, S-Matrix Corp, Eureka, CA Abstract There are many different ways that chromatographer

More information

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer After completing this tutorial you will be able to: Create an Experiment with the Experiment Wizard in FCAP Array software. Export the Experiment

More information

Microplate Systems. Absorbance Microplate Readers 366. Performance Validation and Software Tools 368. Microplate Washer 370

Microplate Systems. Absorbance Microplate Readers 366. Performance Validation and Software Tools 368. Microplate Washer 370 /microplate/ Absorbance Microplate Readers 366 Performance Validation and Software Tools 368 Microplate Washer 370 Singleplex Assays and Reagents 371 Microplate Systems Absorbance Microplate Readers /microplate/

More information

Overview. Experiment Specifications. This tutorial will enable you to

Overview. Experiment Specifications. This tutorial will enable you to Defining a protocol in BioAssay Overview BioAssay provides an interface to store, manipulate, and retrieve biological assay data. The application allows users to define customized protocol tables representing

More information

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

ACQUITY UPLC Systems with 2D Technology Capabilities Guide ACQUITY UPLC Systems with 2D Technology Capabilities Guide Revision A Copyright Waters Corporation 2012 All rights reserved Copyright notice 2012 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA

More information

ACAS Tutorial. Simple Experiment Loader. Contents:

ACAS Tutorial. Simple Experiment Loader. Contents: Simple Experiment Loader Contents: Overall Workflow Loading a Generic Data File Loading a Concentration Data File Adding a Report File Adding Images Validation Errors Editing a Protocol Adding Files to

More information

Enhancing your Lab Workflow with NuGenesis 8 ELN and Empower Waters Corporation 1

Enhancing your Lab Workflow with NuGenesis 8 ELN and Empower Waters Corporation 1 Enhancing your Lab Workflow with NuGenesis 8 ELN and Empower 2013 Waters Corporation 1 Agenda Browse Empower Data Using ELN Documents to Submit Samples and retrieve Results 2013 Waters Corporation 2 Agenda

More information

Troubleshooting Guide

Troubleshooting Guide DS-11 FX Series / DS-C / QFX Technical Note 165 Troubleshooting Guide Rev January 2017 Table of Contents 1. Sample Result Concerns... 4 Microvolume Sample Concentration Accuracy... 4 Microvolume Sample

More information

Wave User Guide XF e Analyzer

Wave User Guide XF e Analyzer Wave User Guide XF e Analyzer October 2014 1 CONTENTS Chapter 1: Designing an XF e Assay Overview of the Process: Design, Run, and Analyze... 6 Step 1: Design XF e assay using Wave Desktop... 6 Step 2:

More information

Installation Guide for Multidrop Combi with Valve Driver for Polara RS

Installation Guide for Multidrop Combi with Valve Driver for Polara RS Installation Guide for Multidrop Combi with Valve Driver for Polara RS Overview The Valve for the Multidrop Combi is a unique product that allows users to change and control up to eight reagents using

More information

Using the Chromeleon Summit 2 Tandem Operation Wizard

Using the Chromeleon Summit 2 Tandem Operation Wizard Technical Note 702 Using the Chromeleon Summit 2 Tandem Operation Wizard 1 INTRODUCTION New Summit 2 Tandem Operation support of the Program Wizard is available in Chromeleon version 6.70. The purpose

More information

COBAS INTEGRA 400 plus

COBAS INTEGRA 400 plus COBAS INTEGRA 400 plus COBAS INTEGRA 400 plus is designed to consolidate testing and increase efficiency while reducing total running costs of the laboratory. The COBAS INTEGRA systems extensive assay

More information

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

LIGHT SOURCE Quartz-iodine lamp 12V-20W. SPECIFICATIONS THROUGHPUT Up to 180 tests per hour; Up to 300 tests per hour with ISE unit. REAGENT SYSTEM Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can

More information

EASY-nLC Series User Guide for the Xcalibur Data System (Xcalibur version 2.1 or later)

EASY-nLC Series User Guide for the Xcalibur Data System (Xcalibur version 2.1 or later) Thermo EASY-nLC Series User Guide for the Xcalibur Data System (Xcalibur version 2.1 or later) P/N 60053-97230 Revision B January 2013 2013 Thermo Fisher Scientific Inc. All rights reserved. EASY-nLC,

More information

OLI Chemistry Wizard 9.5 User Guide

OLI Chemistry Wizard 9.5 User Guide OLI Chemistry Wizard 9.5 User Guide Updated August 17, 2017 OLI Chemistry Wizard is a Windows wizard-style application that leads you through the process of creating an OLI chemistry model file and associated

More information

WHITEPAGES PRO DEEP LINK BUILDER

WHITEPAGES PRO DEEP LINK BUILDER WHITEPAGES PRO DEEP LINK BUILDER Learn how to use and install the Whitepages Pro Deep Link builder to run Identity Check queries via a single click with zero development effort. Whitepages Pro Deep Link

More information

Issued by: LABORATORY MANAGER Original Date: March 14, 2001 Approved by: Laboratory Director Revision Date: June 6, 2003.

Issued by: LABORATORY MANAGER Original Date: March 14, 2001 Approved by: Laboratory Director Revision Date: June 6, 2003. Policy # MI/SER/06/v01 Page 1 of 5 Section: Subject Title: Epstein Barr Virus Serology Issued by: LABORATORY MANAGER Original Date: March 14, 2001 Approved by: Laboratory Director Revision Date: June 6,

More information

Standard Operating Procedure for the Beckman PA/CE MDQ Electrophoresis System. Last Modified October 19, 2012

Standard Operating Procedure for the Beckman PA/CE MDQ Electrophoresis System. Last Modified October 19, 2012 Standard Operating Procedure for the Beckman PA/CE MDQ Electrophoresis System Last Modified October 19, 2012 Considerations Prior to Beginning Experiment All solutions must be filtered (using 0.45 m or

More information

June Fairfax County Health Department

June Fairfax County Health Department June 2016 Fairfax County Health Department Cepheid GeneXpert MTB/RIF Assay CDC/CMS IQCP guidance IQCP Developing an IQCP, A Step-By-Step Guide Manufacturer s IQCP guidance Developing an Individualized

More information

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

3 Starting the chiral HPLC and logging into LC Real Time Analysis. Edition: 1.2 Date: 7-Oct-11 Page 1 of 5 1 Responsibilities. First person responsible: Mariëlle Delville. Second person responsible: Helene I.V. Amatdjais-Groenen. 2 Definitions. Read the information on

More information

NEW IMPROVED SCREENING PLATFORM MATERNAL FETAL HEALTH

NEW IMPROVED SCREENING PLATFORM MATERNAL FETAL HEALTH Introducing the new AutoDELFIA immunoassay system for prenatal screening Brochure not for distribution in the USA NEW IMPROVED MATERNAL FETAL HEALTH SCREENING PLATFORM ALREADY 60 MILLION PREGNANCIES SCREENED

More information

SPA III Quick Reference Guide for Custom Panels

SPA III Quick Reference Guide for Custom Panels SPA III Quick Reference Guide for Custom Panels This guide contains instructions for using the BD FACS Sample Prep Assistant III (SPA III) with BD FACS SPA software version.0 and later. Initial Setup Custom

More information

Xcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures

Xcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures Xcalibur QuickQuan User Guide XCALI-97195 Revision C July 2007 For Research Use Only Not for use in Diagnostic Procedures 2007 Thermo Fisher Scientific Inc. All rights reserved. Microsoft, Access, Excel,

More information

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017 Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017 Introduction This document is only for operation of the HPLC and ICP-MS instruments to obtain data. It contains no maintenance

More information

Crocodile miniworkstation. Your personal ELISA automation

Crocodile miniworkstation. Your personal ELISA automation Crocodile miniworkstation Your personal ELISA automation Crocodile is a compact, fully automated, high performance ELISA workstation for low to medium throughput Under normal circumstances, running your

More information

GENESYS ON-BOARD SOFTWARE RELEASE NOTES

GENESYS ON-BOARD SOFTWARE RELEASE NOTES GENESYS ON-BOARD SOFTWARE RELEASE NOTES... 1 About This Document... 1 GENESYS On-board software v1.0... 2 New Features... 2 Resolved Issues -... 2 Known Issues... 2 GENESYS On-board software v1.1... 2

More information

Setup for Omnia assays on SpectraMax Paradigm Microplate Detection Platform with SoftMax Pro 6 software

Setup for Omnia assays on SpectraMax Paradigm Microplate Detection Platform with SoftMax Pro 6 software Page 1 of 20 Setup for Omnia assays on SpectraMax Paradigm Microplate Detection Platform with SoftMax Pro 6 software The Molecular Devices SpectraMax Paradigm Microplate Detection Platform was tested for

More information

Automating HPLC Analytical Method Development Fusion AE Software Program White Paper

Automating HPLC Analytical Method Development Fusion AE Software Program White Paper Automating HPLC Analytical Method Development Fusion AE Software Program White Paper S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501, USA www.smatrix.com Introduction Chromatographic analytical

More information

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump Precision Instruments for Research and Industry J-KEM Scientific Syringe Pump Program Index Program Description Page # Software Installation 3 Hardware Installation 3 The Timed Addition Program The Multi-Reagent

More information

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes PN 101-6531 D1 RELEASE NOTES Biomark/EP1 Software To download the latest version of the software for Biomark HD, Biomark, and EP1, go to fluidigm.com/software. For more information about updating the software,

More information

OGI-IT (L)IMS. an overview

OGI-IT (L)IMS. an overview OGI-IT (L)IMS an overview IMS-Information Management System Information is stored in databases (DB) - we use document oriented DB so that the DB Model (collections of documents) can match as close as possible

More information

Spark Holland introduces

Spark Holland introduces BETTER SAMPLE CARE Spark Holland introduces ALIAS All-round, state-of-the-art autosampler for HPLC Spark Holland introduces ALIAS All-round, state-of-the-art autosampler for HPLC ALIAS All-round, state-of-the-art

More information

FULLY AUTOMATED 2 MICROPLATE ANALYZER

FULLY AUTOMATED 2 MICROPLATE ANALYZER FULLY AUTOMATED 2 MICROPLATE ANALYZER The new Personal Lab,(Plab) is an integration between our unique extensive expertise and information gathered from thousands of installations. The new Plab is innovative

More information

Product Correction Urgent Immediate Action Required

Product Correction Urgent Immediate Action Required Abbott GmbH & Co. KG Max Planck Ring 2 65205 Wiesbaden, Germany DIAGNOSTICS Urgent Field Safety Notice Product Correction Urgent Immediate Action Required Date d March 8, 2019 Product Product Name List

More information

6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, MMA Technology. Robert Tornai

6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, MMA Technology. Robert Tornai 6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, 2004. MMA Technology Robert Tornai Department of Computer Graphics, University of Debrecen e-mail: rtornai@inf.unideb.hu

More information

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Luminex Prima Theory of Operation Luminex 200 technology is based on flow cell

More information

BA-88A Semi-auto Chemistry Analyzer

BA-88A Semi-auto Chemistry Analyzer BA-88A Semi-auto Chemistry Analyzer Main Contents Features Working principles Improvements from BA-88 Competitors Operation Price FAQ Features Test mode: flowcell or cuvette 7.0 TFT touch screen & popup

More information

Report Generator User Guide

Report Generator User Guide 12 Tra Report Generator User Guide Agilent Seahorse XF Glycolysis Stress Test For research use only. 1 Table of Contents Introduction... 3 Parameter Calculations... 3 XF Report Generator Overview... 4

More information

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation Automated Submission for Analysis Processing (ASAP) Operator s Guide 2002 Dionex Corporation Document No. 031843 Revision 01 May 2002 2002 by Dionex Corporation All rights reserved worldwide. Printed in

More information

The BLR Employee Handbook Builder allows you to create your own customized employee handbook. Benefits include:

The BLR Employee Handbook Builder allows you to create your own customized employee handbook. Benefits include: Introduction to BLR s Employee Handbook Builder The BLR Employee Handbook Builder allows you to create your own customized employee handbook. Benefits include: Ability to work on a handbook from any computer

More information

CounterTrace. Users manual. Version 1.3.0

CounterTrace. Users manual. Version 1.3.0 CounterTrace Users manual Version 1.3.0 February 2004 Table of contents OVERVIEW...3 COUNTERTRACE SYSTEM COMPONENTS...4 COUNTERTRACE LOADING ADDITIVE...4 COUNTERTRACE SOFTWARE...4 COUNTERTRACE LOADING

More information

Thermo. EASY-nLC User Guide for LC Devices

Thermo. EASY-nLC User Guide for LC Devices Thermo EASY-nLC 1200 User Guide for LC Devices 60053-97273 Revision A September 2015 2015 Thermo Fisher Scientific Inc. All rights reserved. AFC, EASY-nLC, EASY-Column, EASY-Spray, Foundation, LC TriPlus,

More information

MiSeqDx Reference Guide

MiSeqDx Reference Guide MiSeqDx Reference Guide for Instruments with Dual Boot Configuration FOR IN VITRO DIAGNOSTIC USE ILLUMINA PROPRIETARY Document # 15070067 Rev. 03 September 2017 This document and its contents are proprietary

More information

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump Precision Instruments for Research and Industry J-KEM Scientific Syringe Pump Program Index Program Description Page # Software Installation 3 Hardware Installation 3 The Timed Addition Program The Multi-Reagent

More information

Sirius Single Tube Luminometer. Highest Performance Utmost Flexibility

Sirius Single Tube Luminometer. Highest Performance Utmost Flexibility Sirius Single Tube Luminometer Highest Performance Utmost Flexibility Sirius Highest Sensitivity and Linearity Concept Sirius can be employed according to the individual needs of each user. In its basic

More information

RIDA GENE real-time PCR DNA Assays

RIDA GENE real-time PCR DNA Assays R-Biopharm AG RIDA GENE real-time PCR DNA Assays Set-up for ABI7500/FAST (Software Version.0) R-Biopharm for reliable diagnostics. Step : To set up a template for DNA Assays After opening the ABI7500 software,

More information

Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version Beta Release 10/05 Release Notes (PN Rev A)

Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version Beta Release 10/05 Release Notes (PN Rev A) Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version 1.3.2 Beta Release 10/05 Release Notes (PN 4370225 Rev A) Software Release notes for: Applied Biosystems RapidFinder Software

More information

Bio-Rad Laboratories AUTOIMMUNE TESTING. System. PhD. IFA and EIA Instrumentation. One revolutionary platform, two technologies

Bio-Rad Laboratories AUTOIMMUNE TESTING. System. PhD. IFA and EIA Instrumentation. One revolutionary platform, two technologies Bio-Rad Laboratories AUTOIMMUNE TESTING IFA and EIA Instrumentation One revolutionary platform, two technologies Bio-Rad Laboratories AUTOIMMUNE TESTING Autoimmune IFA and EIA testing Flexibility, efficiency

More information

ATP ELISA. miniworkstation. Microvolume Spectrometer. Microplate Coating. Luciferase. Assays. Microplate Washer. Reader.

ATP ELISA. miniworkstation. Microvolume Spectrometer. Microplate Coating. Luciferase. Assays. Microplate Washer. Reader. Catalog Life Science Instruments Microvolume Spectrometer ELISA Luciferase Assays A 260/280 Luminometer Detection Microplate Washer miniworkstation Liquid Handling ATP Tube Luminometer Reader Microplate

More information

Agilent GC/MSD Instructions

Agilent GC/MSD Instructions Agilent GC/MSD Instructions GC/MS SAMPLE PREPARATION: Sample Components to Avoid Completely: The following should never be injected: metals, strong acids or bases, salts, oligomeric and polymeric material.

More information

BD Accuri C6 with single tube loader protocol. For multiplex assays

BD Accuri C6 with single tube loader protocol. For multiplex assays BD Accuri C6 with single tube loader protocol For multiplex assays BD Accuri C6 with single tube loader protocol This protocol contains instructions for setting up an Accuri C6 with Tube Loader. If you

More information

Manual HPLC-4 Alliance-UV

Manual HPLC-4 Alliance-UV Manual HPLC-4 Alliance-UV MAKE SURE NEVER TO: 1. pump particles or air through the column. 2. inject when the injector is dry. 3. inject solutions containing particles. 4. apply large (sudden) pressure

More information

PAL Sample Control. Edition Date Version

PAL Sample Control. Edition Date Version Printing History Edition Date Version Edition 8 June 2016 Release 2.4.0.0 (2.4.0.0) Edition 7 December 2015 Release 2.3.0.0 (2.3.0.3) Edition 6 June 2015 Release 2.2.0.0 (2.2.0.2) Edition 5 February 2015

More information

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2. Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.8 Contents 1. Description 1.1 Background information 1.2 Reagent and

More information

Introduction to the HPLC ChemStation and Acquisition

Introduction to the HPLC ChemStation and Acquisition Introduction to the HPLC ChemStation and Acquisition In This Section, We Will Discuss: How to work in the Microsoft Windows Environment The structure of the ChemStation Software. How to set up an acquisition

More information

Digital Humidity Probe, HPL1 (#30009)

Digital Humidity Probe, HPL1 (#30009) Digital Humidity Probe, HPL1 (#30009) The Networked Robotics HPL1 Digital Humidity Probe enables the remote data collection and monitoring of both relative humidity and temperature via standard computer

More information

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached. GC/FID Standard Operating Procedure Environmental health and Safety (EH&S) 2809 Daley Drive Ames, IA 50011-3660 Phone: (515)-294-5359 Fax: (515)-294-9357 www.ehs.iastate.edu Procedure: Department: Bioeconomy

More information

Version 3.0 Quick Reference Guide

Version 3.0 Quick Reference Guide Version.0 Quick Reference Guide Topics TRILUTION LH Software TRILUTION LH Software is software for controlling automated liquid handling instruments. Its innovative features include: simple drag-and-drop

More information

Keithley 2100 v1.06 Firmware Release Notes. Contents. General Information. Supported Models. Installation Instructions

Keithley 2100 v1.06 Firmware Release Notes. Contents. General Information. Supported Models. Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139-1891 440-248-0400 Fax: 440-248-6168 http://www.keithley.com Keithley 2100 v1.06 Firmware Release Notes Contents Contents...1 General Information...1

More information

eprep Sample Preparation Workstation

eprep Sample Preparation Workstation eprep Sample Preparation Workstation Robotic Sample Preparation for the Chromatography Laboratory Easy, precise and affordable workflow automation Area (mau*min) Highly Flexible and Adaptable The eprep

More information

Fusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL:

Fusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL: Fusion AE LC Method Validation Module S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501 USA Phone: 707-441-0404 URL: www.smatrix.com Regulatory Statements and Expectations ICH Q2A The objective

More information

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Getting low-resolution GC-MS data on the JEOL GCMate Introduction Getting low-resolution GC-MS data on the JEOL GCMate Introduction GC-MS is a technique that combines gas phase separation and mass-based detection/characterization of analytes. It s a very sensitive method

More information

ChromQuest 5.0 Quick Reference Guide

ChromQuest 5.0 Quick Reference Guide ChromQuest 5.0 Quick Reference Guide This guide contains an overview of the ChromQuest chromatography data system, with topics organized by workflow. For more information, refer to the ChromQuest User

More information

1. What s New in Bio-Plex Manager 6.1

1. What s New in Bio-Plex Manager 6.1 Bio-Rad Laboratories, Inc. Release Notes Bio-Plex Manager Software, Version 6.1 September 26, 2011 This document has the following sections: 1. What s New in Bio-Plex Manager 6.1 2. Resources for New Users

More information

E-Notebook User Guide

E-Notebook User Guide 1. Introduction E-Notebook Features Facilitates daily record-keeping for the scientists (Managing data, organizing information, streamlining workflow). Conducts searches by substructure, key word, date,

More information

Chromatography Software Training Materials. Contents

Chromatography Software Training Materials. Contents Chromatography Software Training Materials This document contains information on how to build a method, start the instrument to acquire data, and then process the data using the Galaxie Program. You will

More information

BD FACSMelody Cell Sorter Quick Reference Guide

BD FACSMelody Cell Sorter Quick Reference Guide BD FACSMelody Cell Sorter Quick Reference Guide This guide contains instructions for using the BD FACSMelody cell sorter with BD FACSChorus software version. and later. Workflow Overview The following

More information

Veriti Thermal Cycler

Veriti Thermal Cycler product brochure PCR Systems Veriti Thermal Cycler The Power of MORE Applied Biosystems, the most trusted name in PCR instruments, introduces a new line of innovative thermal cyclers The Veriti Thermal

More information

Spark Holland introduces

Spark Holland introduces BETTER SAMPLE CARE Spark Holland introduces DBS Autosampler A revolution in Dried Blood Spot (DBS) Sampling Spark Holland introduces DBS Autosampler A revolution in Dried Blood Spot Sampling The DBS Autosampler

More information

HID Real-Time PCR Analysis Software

HID Real-Time PCR Analysis Software USER GUIDE HID Real-Time PCR Analysis Software Version 1.3 for use with: 7500 Real-Time PCR Instruments QuantStudio 5 Real-Time PCR Instruments (with 0.2-mL 96-Well Block) Quantifiler DNA Quantification

More information

Bulk Creation of Data Acquisition Parameters

Bulk Creation of Data Acquisition Parameters Bulk Creation of Data Acquisition Parameters Item Type text; Proceedings Authors Kupferschmidt, Benjamin Publisher International Foundation for Telemetering Journal International Telemetering Conference

More information

ESR-Auto Plus LIS Interfacing Guide

ESR-Auto Plus LIS Interfacing Guide ESR-Auto Plus LIS Interfacing Guide Model 504, 505, 506 i 880017-4 Information in this manual is subject to change without notice. No part of this publication may be reproduced or distributed in any form

More information

The NGAL Test Application Note for Abbott Architect c8000

The NGAL Test Application Note for Abbott Architect c8000 The NGAL Test Application Note for Abbott Architect c8 General parameters Name: NGAL Assay number: *1 Assay version: 1 Assay type: Photometric Assay availability: Enabled Cal version: 1 Reaction definition

More information

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1)

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1) Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1) Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1) This document provides information on the

More information

FluoroSELECT Fluorometer User s Manual

FluoroSELECT Fluorometer User s Manual FluoroSELECT Fluorometer User s Manual Version 4.4.A Sigma-Aldrich Chemie GmbH Industriestrasse 25 CH-9470 Buchs Switzerland EurTechServ@sial.com techservice@sial.com (US and Canada) sigma-aldrich.com

More information

For additional information, see these documents on the Breeze 2 software DVD:

For additional information, see these documents on the Breeze 2 software DVD: R E L E A S E N O T E S Waters Breeze 2 Read these release notes before you install and operate Breeze 2. They contain information necessary to ensure successful liquid chromatography results, including:

More information

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening Introducing the new AutoDELFIA immunoassay system for newborn screening MAKE THE CHANGE FOR BETTER NEONATAL SCREENING THE WORLD S LEADING SCREENING PLATFORM PerkinElmer s AutoDELFIA immunoassay system

More information

Table of Contents RURO, Inc. All Rights Reserved

Table of Contents RURO, Inc. All Rights Reserved Table of Contents ABOUT THIS GUIDE... 7 Purpose of this Guide...7 ACCESSING THE SYSTEM AS A CLIENT PORTAL USER... 7 Navigating the Client Portal...7 Creating and Submitting a New Requisition...8 Accepting

More information

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system Specifications & more > > System Specifications > > Consumables > > Accessories System Overview Cat. No. 16300 Analyzer type 4 plate fully automated ELISA analyzer Reagent system Open (Human tests predefined)

More information

QUALITY OVERALL SUMMARY - CHEMICAL ENTITIES (Applications for Drug Identification Number Submissions) (QOS-CE (DINA))

QUALITY OVERALL SUMMARY - CHEMICAL ENTITIES (Applications for Drug Identification Number Submissions) (QOS-CE (DINA)) QUALITY OVERALL SUMMARY - CHEMICAL ENTITIES (Applications for Drug Identification Number Submissions) (QOS-CE (DINA)) (version: 2004-04-01) FOREWORD The Quality Overall Summary (QOS) is a summary of the

More information

Roche LightCycler 480

Roche LightCycler 480 Roche LightCycler 480 Instrument Setup Instructions for RT 2 Profiler PCR Array, TaqMan Version A. Preparation Before the Experiment (Presetting the Run Template will save time for your run): 1. Make sure

More information

Leveraging ALCOA+ Principles to Establish a Data Lifecycle Approach for the Validation and Remediation of Data Integrity. Bradford Allen Genentech

Leveraging ALCOA+ Principles to Establish a Data Lifecycle Approach for the Validation and Remediation of Data Integrity. Bradford Allen Genentech Leveraging ALCOA+ Principles to Establish a Data Lifecycle Approach for the Validation and Remediation of Data Integrity Bradford Allen Genentech 1 Agenda Introduction Data Integrity 101 Review What is

More information

OEM FRU TECHNICAL WHITE PAPER

OEM FRU TECHNICAL WHITE PAPER OEM FRU TECHNICAL WHITE PAPER Capabilities and Use Cases of the OEM FRU Storage Feature on Dell EMC PowerEdge Servers ABSTRACT This white paper describes the capabilities of the OEM FRU storage feature

More information

Liquid Handling: BioMek 3000; Protocol Plate Washer; SOP Fraction Collector; Description

Liquid Handling: BioMek 3000; Protocol Plate Washer; SOP Fraction Collector; Description Beckman Coulter BioMek 3K At BRDG Park R126B Liquid Handling: BioMek 3000; Protocol Plate Washer; SOP Fraction Collector; Description Plate Washer, Bio-Plex Pro II @BRDG used with BioPlex Array reader

More information

Quick Guide NC-200. NucleoCounter. to the easiest cell count ever!

Quick Guide NC-200. NucleoCounter. to the easiest cell count ever! Quick Guide to the easiest cell count ever! NucleoCounter NC-00 How to get started Dear NucleoCounter Customer! Thank you for purchasing the NucleoCounter NC-00 offering not only the easiest one-step viability

More information

Target Drillhole Mapping

Target Drillhole Mapping Target Drillhole Mapping The Target system enables you to create a new blank map to fit a defined data range. The data range can be entered manually, or it can be determined from the range of selected

More information

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening MAKE THE CHANGE FOR BETTER NEONATAL SCREENING Introducing the new AutoDELFIA immunoassay system for newborn screening THE WORLD S LEADING SCREENING PLATFORM PerkinElmer s AutoDELFIA immunoassay system

More information

Basic CBPro Workflow

Basic CBPro Workflow ClockBuilder Pro Overview What is Clock Builder Pro? ClockBuilder Pro (CBPro) is Silicon Labs newest generation of timing device configuration & development tools targeted to next generation Si534x and

More information