1 K44 Code lock GB Technical manual

2 Copyright 2002 Bewator AB, Solna, Sweden. Material from the K44 Technical manual may only be copied with the consent in writing of Bewator. Bewator reserves the right to alter both the content of the manual and the design of the product. Document number: Bewator AB is part of the Swedish Bewator Group AB, which develops and markets a complete security product range that includes access control and alarm. Sales, installation and servicing are handled by a national dealer network. Actions (such as unauthorised manipulation, copying etc.), must not be taken with the software contained in the products and systems. Such actions are regarded as copyright violation and may result in imprisonment or fines and may likewise lead to an obligation to pay damages and compensation for using the software.

3 K44 Technical manual 3 What is K44?... 4 Timing the codes... 4 Standard mode and advanced mode... 5 Duress... 5 Zero opening... 5 The keypad... 8 Wiring... 6 Buzzer and LEDs... 9 Choose password Change password Programming the codes Erasing codes Changing codes Set opening time Deactivating the Buzzer Door open permanently Duress on/off Standard mode or advanced Erase the memory Using K Entrance Unlock the door permanently Enter duress code Technical data Programming overview... 22

4 4 K44 Technical manual What is K44? K44 is a compact code lock designed for one door. To open the door, a four-digit entrance code is used (six-digit codes can be used in advanced mode). All programming is done using the keypad. Timing the codes K44 offers the possibility to time the codes you have programmed via an external time clock. This is useful if certain codes, e.g. the cleaner's code, should only be valid certain hours while the staff should have access to the door 24 hours a day. Connecting two time clocks to K44, you can make use of three different time zones for code timing: one controlled by time clock 1, one controlled by time clock 2 and one valid 24 hours a day, i.e. no timing. When programming the codes you should determine to what time control group they should belong. 0 = no timing, 1 = group 1 and 2 = group 2.

5 K44 Technical manual 5 Standard mode and advanced mode K44 is delivered in standard mode, which means you can program up to four different four-digit codes. If you set the code lock to advanced mode you can program 20 four-digit and 10 six-digit codes. Duress K44 is equipped with an output for duress. If a person is forced to open the door under threat, he or she can enter a special code activating an alarm (if connected). Zero opening To facilitate entrance, e.g. during office hours, you can connect an external contact enabling you to activate or deactivate the possibility to open the door by simply pressing the zero button on the keypad

6 6 K44 Technical manual Wiring The numbers refer to the diagram on the right. 1 Electric locking device. Dashed line refers to locks with failsafe function. 2 Voltage feed in, terminal block nos. 1 and 2. 3 Contact for zero opening. Close terminal block nos 6 and 7 (or 13). 4 Timing from external time clock. Input 1: close terminal block nos. 9 and 7 (or 13). Input 2: close nos. 8 and 7 (or 13). 5 Remote opening button. Close terminal block pos. 10 and 7 (or 13). 6 Door bell. Output for activating a buzzer or similar. Always use relay E7 (connect between nos. 11 and 2(+). 7 Duress. Output for activating e.g. an alarm. Always use relay E7 (connect between nos. 12 and 2(+). 8 Tamper switch. Normally closed when the housing is closed. 9 Extra LED. Max. voltage 30V DC. 10 Remove the jumper if background lighting is not desired. 11 If the voltage feed is below 20 V, set the jumper to 12 V.

7 K44 Technical manual 7

8 8 K44 Technical manual The keypad Yellow LED Indicates keypresses B Green LED Lit when the lock is open. B Press B and enter the 6-digit password to program K44. Press B to leave programming mode. = A Functions as a door bell and starts the sequence telling K44 what you want to program, e.g. A21 to program codes.

9 K44 Technical manual 9 Programming Before you start programming K44 it might be a good idea to make a note of the codes to program and to which timing group they should belong. On the inside cover you will find a chart designed for this purpose. When programming, look at your notes and follow the instructions below. Buzzer and LEDs During programming you will be guided by the buzzer and the LEDs. In programming mode before a function is chosen: The buzzer sounds with short beeps during which both LEDs. During programming: The beeps come in shorter intervals. The LEDs are lit, off or flashes depending on the function being programmed. Correct instruction: Confirmed by a rising signal consisting of two quick beeps. Faulty instruction: Confirmed by a falling signal consisting of two quick beeps.

10 10 K44 Technical manual In this manual the LEDs are illustrated in the following way: = Off = Lit = Flashes Note 1! In all programming instructions below A (in e.g. A21) refers to the bell button the keypad Note 2! During programming mode, if a button is not pressed within 20 seconds, the code lock goes back to normal operation. Choose password When K44 is delivered, the memory is completely erased. The first thing to do before installing the code lock is to choose a password. Proceed as follows: 1 Press the SWl button on the code lock's circuit board. Both LEDs start flashing at the same time as the buzzer sounds. 2 Enter a 6-digit password. 3 Make a note of the new password and keep it in safe place.

11 K44 Technical manual 11 Change password 1 Press B and enter the current password. 2 Enter A27. 3 Enter the new password. A warning tone is heard. 4 Enter the new password once again. 5 Press B to leave programming mode. 6 Make a note of the new password and keep it in safe place. Programming the codes 1 Press B and enter the password. 2 Enter A21. 3 Enter the desired code location using two digits (01-04 if K44 is in standard mode or if K44 is in advanced mode). Note! In the Standard mode or advanced mode section you will find instructions on how to change the setting between standard and advanced mode. 4 Enter the entrance code for the chosen code location (four digits for code locations or six digits for code locations 21-30).

12 12 K44 Technical manual Note! The first four digits in a six-digit code must not be equal to the digits in a four-digit code and vice versa. 5 State whether the code should be timed from an external time clock. Press 0 if the code should not be timed. Press 1 if the code should be timed from time clock 1 or 2 if it should be timed from time clock 2. 6 Enter a new code location or press B to leave code programming. 7 Press B (leaves programming mode). Erasing codes 1 Press B and enter the password. 2 Press A21. 3 Enter the two-digit code location to which the code belongs. 4 If the code consists of four digits, press 0000 If the code consists of six digits, press Press B to leave code programming. 6 Press B to leave programming mode.

13 K44 Technical manual 13 Changing codes 1 Press B and enter the password. 2 Enter A22. 3 Enter the existing code. If it is a 4-digit code, enter A after the last digit. 4 Enter the new code using four (standard mode) or six digits (advanced mode). 5 Enter the new code once again. 6 If the code should not be timed, press 0. Press 1 if the code should be timed from time clock 1 - or 2 for time clock 2. 7 Change another code or press B to leave code programming. 8 Press B to leave programming mode. Set opening time The opening time determines for how long the lock should remain open following a correct entrance code. When K44 is delivered the opening time is 7 seconds for both relays. 1 Press B and enter the password. 2 Enter A28. 3 Enter the desired opening time (01-99) using two digits, e.g. 09 for 9 seconds. 4 Press B to leave programming mode.

14 14 K44 Technical manual Deactivating the buzzer When K44 is delivered the buzzer is activated. If you do not want the buzzer to beep during key presses and door opening, you can turn it off. Note that the buzzer will continue beeping during programming. 1 Press B and enter the password. 2 Enter A65. 3 Enter 0. 4 Press B to leave programming mode. To activate the buzzer again, press 1 in step 3 instead.

15 K44 Technical manual 15 Door open permanently When K44 is delivered, the code lock is set so that you cannot unlock the door permanently using the code for code location 04. To activate this possibility, proceed as follows: 1 Press B and enter the password. 2 Enter A68. 3 Enter 1. 4 Press B to leave programming mode. Whenever you want to deactivate the function, enter 0 in step 3 instead. In the Unlocking the door permanently section you will find instructions on how to unlock the door using the code.

16 16 K44 Technical manual Duress on/off With the duress function activated, a staff member can enter a special code if he or she is forced to open the door under theat. An alarm signal is then transmitted to an alarm central, the police or similar. When K44 is delivered, the duress function is deactivated. This is how to activate the duress function: 1 Press B and enter the password. 2 Enter A69. 3 Enter 1. 4 Press B. To deactivate the function, enter 0 in step 3 instead. The Enter duress code section describes how a user should enter the duress code. Note! If Duress is activated, make sure you have not programmed codes with consecutive digits. Code 1234 must not exist with codes 1235 and Code 5679 must not exist with codes 5670 and 5678.

17 K44 Technical manual 17 Standard mode or advanced When K44 is delivered, the code lock is set to standard mode. This means that 4 four-digit codes can be programmed. If set to advanced mode, you can program 20 four-digit and 10 six-digit codes. This is how to set K44 to advanced mode: 1 Press B and enter the password. 2 Enter A99. 3 Enter 1. 4 Press B to leave programming mode. To reset K44 to standard mode, enter 0 in step 3 instead. Erase the memory This is how to erase all programmed information (including the password): 1 Press B and enter the password. 2 Press SW1 on K44 circuit board. 3 Enter Enter once again. The memory is now erased and K44 goes back to the factory settings.

18 18 K44 Technical manual Using K44 Entrance To open the lock, a four-digit (or six-digit) entrance code should be entered on the code lock's keypad. When a correct code is entered the lock opens. The lock will close again after the time set as opening time. K44 is blocked if a visitor performs 12 key presses without managing to find a correct entrance code. To release the blockage, enter a correct code twice in succession. Unlock the door permanently To unlock the door permanently, proceed as follows: 1 Press B. 2 Enter the code programmed for code location Enter 1. From now on the visitor does not have to enter a code to open the door the door is unlocked (indicated by the green LED. Whenever you want to lock the door again, follow the instructions above; only enter 0 in step 3 instead. The visitor now has to enter a code to open the door.

19 K44 Technical manual 19 Enter duress code This is how to activate the alarm output when forced to open the door under threat: 1 Enter the usual entrance code, only add 1 to the last digit in the code. Example 1: If the entrance code is 1234, enter 1235 instead. Example 2: If the code is 1239, enter 1230 instead. When a duress code is entered, the door will open at the same time as the duress output is activated. It will remain activated until reset by somebody entering programming mode.

20 20 K44 Technical manual Technical data Power supply: Power consumption: Maximum load over the relay contacts: Dimensions: Suitable height: 8-24V AC, 10-35V DC 7 ma quiescent without backlighting, 35 ma with backlighting. 2 A 28 V DC 140x80x40 mm (HxWxD) mm from ground to bottom edge If needed, complete the installation with flush mounting kit BB3.

21 K44 Technical manual 21 This page is empty

22 Programming overview Always start by pressing B and entering the password. Exit: Press B. Function Sequence Step 1 Step 2 Step 3 Step 4 Step 5 New entrance code A21 Enter code location (2 digits). Change entrance code A22 Enter old code using 4 (+A ) or 6 digits Change password A27 Enter new code (6 digits) Change opening time A28 Enter seconds (01-99) Buzzer on/off A65 0 = off 1 = on Door open permanently A68 0 = off 1 = on Duress on/off A69 0 = off 1 = on Advanced mode on/off A99 0 = off 1 = on Enter code (4 or 6 digits) Enter new code using 4 or 6 digits Enter new code again Enter timing group (0, 1 or 2) Enter new code using 4 or 6 digits Program new code or press B Enter timing group (0, 1 or 2) Change another code or press B

23 Nr Code Time group

24

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS

More information

FTK5 PROXIMITY KEYPAD

FTK5 PROXIMITY KEYPAD FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

SK-1011-SQ Digital Access Keypad with 5A Relay Output

SK-1011-SQ Digital Access Keypad with 5A Relay Output User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u

More information

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description. SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming

More information

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads User Operation for the SK--SQ Note: n n n nindicates. Using the User Codes: A. User codes operate the door (4-8 digits long). the inhibit code. Note: u u u uindicates Press u u u u the user code. B. The

More information

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram BHD-8000 Access Control Keypad and Card Reader Wiring Diagram Frontal View Main Technical Specifications Item Operating Voltage Unlock Relay Operating Temperature Value 12VDC+12%/1.2A 12VDC/2A Normal Operation:

More information

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A. Compact Keypad Grey Exit button (push to make) 1V DC White Black 115V DC (fuse rating 1A) 1V DC release current rating must be less than 1A. The diode current rating must be equal to or greater than the

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader Features: Rugged construction heavy-duty stainless steel faceplate with coated steel housing Built-in proximity card reader 12~24

More information

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2 EcoEntry RFID Proximity Access Control System User Guide Revision 2 Introduction The ecoentry door access system allows the user to open the door using a keyfob, password, or keyfob plus password. Specification

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT

BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT CAA/SE BACK-LIT KEYS KEYPAD 100 USER CODES FLUSH MOUNT The visual feedback with the green, amber and red LED s is always active. It is possible to activate the audible feedback by putting ST1 jumper on

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions CM-120TX Wireless Digital Keypads Installation Instructions Package Contents - (1) Keypad and faceplate assembly - (1) Foam gasket (CM-120W only) - (2) #6-32 x 1 S/S Phillips screws - (2) #6-32 x 1 Tamperproof

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Creone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet: All data

Creone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet:   All data INSTRUCTION MANUAL Keybox 9000 Basic Keybox 9000 System Keybox 9000 Expansion KeyWin Light Creone AB Box 148 S-573 22 Tranås SWEDEN Tel: +46(0)140-38 61 80 Fax: +46(0)140-38 61 89 E-mail: mailbox@creone.com

More information

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack Access codes Contents Unset system indications - - - - - - - - - - - System indication - - - - - - - - - - - - Access codes - - - - - - - - - - - - - - - - How to operate Personal - - - - - - How to unset

More information

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out

More information

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following: ins-016 160499 TOUCHLOCK compact 100-050 TOUCHLOCK compact kit Instructions for the following: 526-886 TOUCHLOCK compact keypad 100-050 TOUCHLOCK compact kit Master code: Document Contents About this product...2

More information

Technical help is available: Monday - Friday from 02:00 AM - 8:00 PM (EST)

Technical help is available: Monday - Friday from 02:00 AM - 8:00 PM (EST) 0/07/013 Ins-30109-US Vandal resistant compact metal keypad Paxton Technical Support 1.00.7.79 supportus@paxton-access.com Technical help is available: Monday - Friday from 0:00 AM - :00 PM (EST) Documentation

More information

D2112 Keypad Diagnostics

D2112 Keypad Diagnostics D2112 Keypad Diagnostics Putting the Keypad into the Diagnostics Mode 1. Lock the D2112's Standby Switch down. 2. Press the 1 key on the keypad. 3. Enter your Installer passcode. The default Installer

More information

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations 9800 XP-KIT Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations Programming & Operations Manual KIT CONTENTS: Programming Keypad Programming Master Card Pack 0 Blank Proximity Cards

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

BC Digital Keypad. User Manual

BC Digital Keypad. User Manual BC2200 Digital Keypad User Manual Name Digital Keypad BC2200 User manual Screw driver Rubber bungs Self tapping screws Diode 1. Packing List Quantity Remarks 1 1 1 4 Φ6mm 28 mm, used for fixing 4 Φ4mm

More information

Stand-alone Proximity Access Control

Stand-alone Proximity Access Control Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses

More information

U-FLASH Setup Guide U-FLASH.

U-FLASH Setup Guide U-FLASH. U-FLASH Setup Guide Thank you for purchasing the U-FLASH. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01 ROSSLARE MODE 1 2 DOOR 3 4 5 6 7 8 9 0 # AC-115 Hardware Installation and User s Guide 10/01 ROSSLARE Hardware Installation and User s Guide for the AC-115 Access Control System MODE 1 2 DOOR 3 4 5 6 7

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

TOUCHLOCK compact. Ins-182 Date code:

TOUCHLOCK compact. Ins-182 Date code: TOUCHLOCK compact Ins-82 Date code: 0050 About TOUCHLOCK compact is a single door, single keypad access control system. The keypad is suitable for internal and sheltered external installations and for

More information

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads Quick Reference Guide. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must be pressed also if the keypad is in manual-entry mode. Press u u u u Note: u

More information

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features Audio Door Entry with Access Control ACTentry A5 Kit Audio Door Entry & Access Control Kit Each kit comprises a door entry panel intercom power supply unit ACTEntryA5ICOM-K ACTentry A5 Entry Panel Audio

More information

The HAUSSMANN RIRI keypad

The HAUSSMANN RIRI keypad The HAUSSMANN RIRI keypad YOUR HAUSSMANN RIRI KEYPAD IS EVOLVING Until now, you could only use the keypad itself, but now it is possible to connect other equipment to it enabling you to control keypad

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

Ins Switch2 quickstart guide

Ins Switch2 quickstart guide 12V Red LED Amber LED Green LED Data Clock Media Detect 0V Contact Exit Alarm Bell 12V 0V N.C. N.O. COM http://paxton.info/107 PLACE SERIAL 123456 NUMBER LABEL HERE Switch2 Ins-30010 Switch2 quickstart

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

2 IDS LCD Keypad User Manual C Issued March 2009

2 IDS LCD Keypad User Manual C Issued March 2009 2 3 4 Contents 1. Introduction to the IDS LCD Digital Keypad...8 2. Arming the Control Panel...8 2.1 Away Arming...8 2.1.1 How to Away Arm...8 2.1.2 Quick Away Arm Shortcut Key...8 2.2 Stay Arming...9

More information

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,

More information

VIS-3200 / VIS-3201 User Manual

VIS-3200 / VIS-3201 User Manual 2.4GHz Indoor Black Wireless Exit Button Receiver Keypad / Reader Access Control 500 Users Range of 50 Feet Delay and On/Off Toggle Mode Battery Operated Standalone No Software 1 VIS-3200 / VIS-3201 User

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

Integriti User Manual. Elite / EliteX LCD Terminal Keypads Integriti User Manual Elite / EliteX LCD Terminal Keypads INNER RANGE recommends that all INTEGRITI systems are installed & maintained by FACTORY CERTIFIED TECHNICIANS. For a list of Accredited Dealers

More information

SK-1011-SDQ Access Control Keypad. Manual

SK-1011-SDQ Access Control Keypad. Manual SK-1011-SDQ Access Control Keypad Manual Quick Installation Guide: This page is for installers looking to do a basic installation and programming of the keypad. For more in-depth installation and programming

More information

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions AC010S Compact AS-i E-STOP safety module Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................

More information

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details EN FULL DETAILS SKB Vandal Resistant keypad - Full Details WARNINGS Carry out the installation by carefully following the instructions provided by the manufacturer in accordance with the current standards.

More information

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation -V/AB & ABK V.5 (2 ) Important Notes: ) Before you install this equipment, please read this full manual. Installation Manual Wiring 8) Carefully follow the wiring instructions. 2) Before fully installing

More information

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM Doc. 6001012 Rev B PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM ALPHA COMMUNICATIONS 42 Central Drive Farmingdale NY 11735-1202 Phone: 631-777-5500 - Fax: 631-777-5599 IMPORTANT NOTICE If the

More information

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox standalone ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox ACT 5e prox 2R.indd 1 19/02/2016 17:05:06 ACTstandalone Robust and Reliable. 1 ACT 5e prox 2R.indd 2 19/02/2016

More information

PT DC 70 MBPT. Vandal Resistant, Back-Lit Weatherproof, Access Control. Keypad. Notes. Keypad. Programming Instructions

PT DC 70 MBPT. Vandal Resistant, Back-Lit Weatherproof, Access Control. Keypad. Notes. Keypad. Programming Instructions Notes February 2012 Keypad Programming Instructions PT DC 70 MBPT Vandal Resistant, Back-Lit Weatherproof, ccess Control Keypad Distributed in the UK by For electric lock, inter-lock and security system

More information

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Iso DIN. User Manual. 1 channel Earth Fault Monitoring Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

IDS.  Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2. INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-146-01D ISSUED NOVEMBER 2002 VERSION 2.17 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm

More information

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you 1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as

More information

_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG

_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG 18020502_A_en_LED6VG VOICE GUIDE KEYPAD LED6VG Disclaimer While every effort has been made to ensure that the information in this manual is accurate and complete, no liability can be accepted for any errors

More information

Installing Keypad and Backplate

Installing Keypad and Backplate Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using

More information

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring

More information

Colour Graphic Terminal User Manual. Rev 3.1

Colour Graphic Terminal User Manual. Rev 3.1 Integriti. Colour Graphic Terminal User Manual. 1 Colour Graphic Terminal User Manual. Rev 3.1 2013-2014. Inner Range Pty. Ltd. Part Number: 636000U 2 Integriti. Revision 3.1 June 2014. SYSTEM DETAILS

More information

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD Entryphone PinNet 4 Product manual October 2010 R4.9 www.entryphone.co.uk 23 Granville Road, London SW18 5SD This document covers the installation and use of the Entryphone on-line PinNet door control

More information

-DTZ001- Stand-Alone Proximity Access Control. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual -DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

IDS X-Series User Manual E Issued June 2013

IDS X-Series User Manual E Issued June 2013 1 2 Contents 1. Introduction to the IDS X-Series Panels... 6 2. Before Operating Your Alarm System... 6 3. Understanding the Keypad LEDs... 7 3.1 Viewing Data on an LED Keypad... 11 3.2 Entering Data on

More information

TOUCHLOCK compact keypad Stainless Steel

TOUCHLOCK compact keypad Stainless Steel ins-47 3 TOUCHLOCK compact keypad Stainless Steel 527-38 TOUCHLOCK compact keypad SS Instructions for the following: 527-38 TOUCHLOCK compact keypad SS 53-588 TOUCHLOCK compact kit SS Master code: Document

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

3.3: Setting momentary / latching switches Page Warning Regarding Operation Page 8

3.3: Setting momentary / latching switches Page Warning Regarding Operation Page 8 Installation Guide Contents: Introduction Page 2 1.0 Unpacking & Pre-Installation Page 2 1.1 Description of parts Page 2 2.0 Cable colour & operations Page 3 2.1 Connections on control pcb Page 3 2.2 Fig

More information

605 D E C T G I n t e r c o m

605 D E C T G I n t e r c o m Installation & User Manual For 605 D E C T + 2. 4 G I n t e r c o m Wireless Video Intercom System Models 605AB, 605ABK P a g e 1 Contents Overview of system.pg 3 Site Survey.Pg 3 Mounting the Transmitter.Pg

More information

alarm shop WEATHERPROOF, MULLION MOUNT ACCESS CONTROL READER KEYPAD DK-2890 Programming & Installation Manual RoHS Compliance

alarm shop WEATHERPROOF, MULLION MOUNT ACCESS CONTROL READER KEYPAD DK-2890 Programming & Installation Manual RoHS Compliance WEATHERPROOF, MULLION MOUNT ACCESS CONTROL READER KEYPAD RoHS Compliance WITH APO DATA I/O PORT DK-2890 Programming & Installation Manual FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT-ON

More information

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because

More information

Modules Programming Guide. paradox.com

Modules Programming Guide. paradox.com Keypad Modules Annunciator Module Motion Detector Modules Zone Expansion Modules Access Control Module Voice Assisted Modules Accessory Modules Integration Module Internet Module Modules Programming Guide

More information

Welcome Contents Diagram

Welcome Contents Diagram Welcome Congratulations on your purchase of our GBF PL960 Series of IP Doorbells. Our factory engineers were the first to enable viewing of multiple security cameras through your handheld smart device,

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

MANUAL PIN CODE KEYPAD February 2013

MANUAL PIN CODE KEYPAD February 2013 February 2013 2 1.0. General information 4 1.1 Safety Remarks 4 1.2 Product Description 5 2.0 Functional Overview 5 2.1 Function Overview 5 2.2 Operating modes 6 2.3 Operating 6 3.0 Start-up 7 4.0 Programming

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ ) e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ 18990-04) Table of Contents Introduction... 1 e-fob Operation and

More information

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2 ATLAS 8 PLUSTM USER GUIDE LED & LCD The equipment has been approved to CTR21for pan-european single terminal connection to the Public Switched Telephone Network (PSTN). However, due to differences between

More information

Vandal-resistant entrance panel

Vandal-resistant entrance panel 308040 LE05231AC-01PC-17W41 www.bticino.com Contents Vandal-resistant entrance panel Introduction 5 Warnings and recommendations 5 What s in your box 5 Description 6 Front view 6 Back view 7 Installation

More information

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly Model MUGAPLM Multi-Unit Gate Access Panel Overview The Multi-Unit Gate Access Panel (MUGAPLM) uses a digitally secure intercom link that allows it to control up to four gate operators and other accessories.

More information

RBR-SB-KTZ001 LAR 2. User Manual

RBR-SB-KTZ001 LAR 2. User Manual RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.

More information