RATINGS AND SPECIFICATIONS
|
|
- Isaac Curtis Wilkerson
- 5 years ago
- Views:
Transcription
1 RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC , EN , JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 125 Model E125 S125 Number of Poles 1 Type NJ NF Nominal current ratings I n (A) o C,32,, 16,,25, 63,,125 32,,, 63, 0,,125 Electrical characteristics Rated operational voltage U e (V) AC /60 Hz DC 0 Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Ultimate breaking capacity I cu (ka) V AC (IEC, JIS, AS/NZS) 525V AC 4V AC 0/4V AC 25 2/2V AC V DC 25 Service breaking capacity I cs (ka) V AC (IEC, JIS, AS/NZS) 525V AC 6 4V AC 12 0/4V AC 19 2/2V AC V DC 19 Rated breaking capacity (NEMA) (ka) V AC 2VAC Protection Adjustable thermal, adjustable magnetic Fixed thermal, fixed magnetic Microprocessor Utilisation category A A Installation Front connection (FC) Extension bar (FB) Cable clamp (FW) Rear connection (RC) Plugin (PM) Draw out (DR) DIN rail mounting (DA) Dimensions h (mm) 5 5 w (mm) 3 pole, (1 pole) 90 () 4 pole 1 d (mm) 6 6 Weight W (kg) 3 pole, (1 pole) 1.1 (0.) 4 pole 1.4 Operation Direct Opening Action Toggle operation Door mounted (HS, HP) / Breaker mounted handle (HB) Motor operation (MC) Endurance Electrical cycles 4V AC Mechanical cycles page The Ultimate Safety Breaker Standard Optional Not Available
2 RATINGS AND SPECIFICATIONS 160 S125 S125 H125 L125 S160 S160 S160 H160 L160 3,4 1 NJ GJ NJ NJ NF NJ GJ NJ NJ SECTION 2,32,,,32,,,32,,,32,, 16,,25,32,,32,,63,,63,, ,,125 63,,125 63,,125 63,,125,,63,0,,125, ,160,125, (5*) (1*) (1*) (*) (42*) (*) (5*) (1*) (1*) / 36/ (25*) (35*) (25*) (1*) (42*) A A A A A A A A A (35) (0.5) ,000,000,000,000,000,000 *Applies only to A and 32A models The Ultimate Safety Breaker page 16
3 RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC , EN , JIS C 121 ANN.1, AS/NZS 39472, NEMA AB1 Frame Quantity Unit Condition 2 Model E2 S2 S2 S2 S2 Number of Poles Type NJ NJ GJ NE GE Nominal current ratings I n (A) o C, ,,, , 125,, ,0 2 2 Electrical characteristics 2 Rated operational voltage U e (V) AC /60 Hz 525 DC Rated insulation voltage U i (V) Rated impulse withstand voltage U imp (kv) Ultimate breaking capacity I cu (ka) V AC (IEC, JIS, AS/NZS) 525V AC V AC /4V AC /2V AC V DC 25 Service breaking capacity I cs (ka) V AC (IEC, JIS, AS/NZS) 525V AC V AC /4V AC /2V AC V DC 19 Rated breaking capacity (NEMA) (ka) V AC VAC Rated shorttime withstand current I cw (ka) 0.3 Seconds Protection Adjustable thermal, adjustable magnetic Fixed thermal, fixed magnetic Microprocessor Utilisation category A A A A A Installation Front connection (FC) Extension bar (FB) Cable clamp (FW) Rear connection (RC) Plugin (PM) Draw out (DR) DIN rail mounting (DA) Dimensions h (mm) w (mm) 3 pole (mm) 4 pole d (mm) Weight W (kg) 3 pole pole Operation Direct Opening Action Toggle operation Door mounted (HS, HP) / Breaker mounted handle (HB) Motor operation (MC) Endurance Electrical cycles 4V AC Mechanical cycles page 17 The Ultimate Safety Breaker Standard Optional Not Available
4 RATINGS AND SPECIFICATIONS 0 6 S2 H2 H2 L2 E0 S0 S0 S0 S0 S0 S0 S0 H0 L0 E6 S6 S6 3,4 3,4 PE NJ NE NJ NJ CJ NJ NE GJ GE PJ PE NE NE NE CE GE SECTION 2, 160,, 160, 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, , 2** 125, 2** * * * * * * * * * A A A A A A A B A B A B B B A A A ,000,000 *MCCB cannot be used in IT systems at this voltage. **Max. rating 225A for Plugin. Refer to Temperature Ratings, Section 6. Contact us for details. 4,0,000 4,0,000 The Ultimate Safety Breaker page 1
5 RATINGS AND SPECIFICATIONS MCCB ELECTRICAL CHARACTERISTICS TO IEC , EN , JIS C 121 ANN.1, AS/NZS , NEMA AB1 Frame Model Number of Poles Type Quantity Unit Condition 00 S00 CJ S00 NJ Nominal current ratings I n (A) C Electrical characteristics Rated operational voltage Rated insulation voltage Rated impulse withstand voltage Ultimate breaking capacity (IEC, JIS, AS/NZS) Service breaking capacity (IEC, JIS, AS/NZS) Rated breaking capacity (NEMA) Rated shorttime withstand current U e U i U imp I cu I cs I cw (V) (V) (kv) (ka) (ka) (ka) (ka) AC /60 Hz DC V AC 525V AC 4V AC 0/4V AC 2/2V AC 2V DC V AC 525V AC 4V AC 0/4V AC 2/2V AC 2V DC V AC 2VAC 0.3 Seconds * * 36 * * * 5 * 5 5 Protection Adjustable thermal, adjustable magnetic (TMD) Fixed thermal, fixed magnetic (TMF) Microprocessor (LSI/LSIG) Utilisation category A A Installation Front connection (FC) Extension bar (FB) Cable clamp (FW) Rear connection (RC) Plugin (PM) Drawout (DR) DIN rail mounting (DA) Dimensions Weight h w d W (mm) (mm) (mm) (kg) 3 pole 4 pole 3 pole 4 pole (3) (3) Operation Direct Opening Action Toggle operation Door mounted (HS, HP) / Breaker mounted handle (HB) Motor operation (MC) Endurance Electrical Mechanical cycles cycles 4V AC 4,000,000 page 19 The Ultimate Safety Breaker *MCCB cannot be used in IT systems at this voltage. Standard Optional Not Available
6 SECTION 2 The Ultimate Safety Breaker page RATINGS AND SPECIFICATIONS S00 RE * 35 * B (3) (4) (5) S00 NE * 5 * 5 5 B (3) (4) (5) S00 RJ * * A (3) H00 NE * * B 273 (6) (7) L00 NE * 0 0 * B 273 (6) (7) 0 S0 SE 0 00 * 5 * A S0 NE * * A S12 SE * 5 * B S12 NE * * B S12 GE * 5 5 (1) * (2) B S1600 SE * 5 * B S1600 NE * 5 5 (1) * (2) B ,000,000 4,000,000 2,000 5,000 4,000 5,000 (1) ka at 0V (2) 75kA at 0V (3) 6A only (4).7kg/6A, 9.1kg/00A (5) 11.9kg/6A, 12.3kg/00A (6) 13.3kg/6A, 14.kg/00A (7) 16.kg/6A, 1.kg/00A
7 OPERATING CHARACTERISTICS THERMAL MAGNETIC CHARACTERISTICS 125A Frame Time/current characteristic curves E125NJ, S125NJ, S125GJ Time/current characteristic curves E125NJ, S125NJ, S125GJ ±4 34±77 600±1 756±1 ± ±2 A(max) 32A(max) 125A(max) A(min) 32A(min) 125A(min) LO HI Adjustable setting range of magnetic trip LO HI Adjustable setting range of magnetic trip page 29 The Ultimate Safety Breaker
8 OPERATING CHARACTERISTICS THERMAL MAGNETIC CHARACTERISTICS 125A Frame Time/current characteristic curves H125NJ, L125NJ SECTION 3 The Ultimate Safety Breaker page
9 OPERATING CHARACTERISTICS THERMAL MAGNETIC CHARACTERISTICS 160A and 2A Frames Time/current characteristic curves S160NJ, S160GJ, E2NJ, S2NJ, S2GJ Time/current characteristic curves E2NJ, S2NJ, S2GJ 2 ±0 0A(max) 2A(max) 0A(min) 2A(min) page 31 The Ultimate Safety Breaker
10 OPERATING CHARACTERISTICS THERMAL MAGNETIC CHARACTERISTICS 160A and 2A Frames Time/current characteristic curves H160NJ, H2NJ, L160NJ, L2NJ Time/current characteristic curves H2NJ, L2NJ Magnetic trip current for Front connection and Rear connection 2 ±0 SECTION 3 2A(max) 2A(min) For Plugin connection, Max. rating 225A I i =2925A±55A The Ultimate Safety Breaker page 32
11 OPERATING CHARACTERISTICS THERMAL MAGNETIC CHARACTERISTICS 0A Frame Time/current characteristic curves E0NJ, S0CJ, S0NJ, S0GJ, S0PJ page 33 The Ultimate Safety Breaker
12 OPERATING CHARACTERISTICS THERMAL MAGNETIC CHARACTERISTICS 00A Frame Time/current characteristic curves S00CJ, S00NJ, S00RJ Time/current characteristic curves S00CJ, S00NJ, S00RJ Tripping Time second minute hour A(min.) 6A(max.) LO HI Magnetic trip current I n (A) 6 I i (A) 60±1260 Adjustable setting range of magnectic trip Tripping Time second minute hour A(min.) 00A(max.) LO HI Magnetic trip current I n (A) I i (A) ±1600 Adjustable setting range of magnectic trip SECTION Percent Rated Current Percent Rated Current Ambient compensating curves Ambient compensating curves 1 1 Percent current rating (%) I n x 0.63 I n x 0. I n x 1.0 Calibrated Temperature Percent current rating (%) I n x 0.63 I n x 0. I n x 1.0 Calibrated Temperature Calibrated at C Ambient Temperature ( C) Calibrated at C Ambient Temperature ( C) The Ultimate Safety Breaker page 34
13 OPERATING CHARACTERISTICS ELECTRONIC CHARACTERISTICS (STANDARD TYPE) S0SE, S0NE 3 Tripping Time second minute hour T I R I p t R t p I g I sd tsd t g I i I SECTION Percent Rated Current I n Percent Rated Current I R I n = 0A IR (A) LTD Pickup current I R xin Standard Option LT ST INST PTA GF Note(3) NP Characteristics t R I sd tsd Ii Ip t p I g tg IN tn No at 0% x I R at 600% x IR xi R xi R 14(Max: x I n) Note (1) xir 0. xin xir /0.5 Note(2) t N=tR Note (1) I i max. = x I n. (2) 1.0 x IR or 0.5 x IR can be selected. Characteristic of neutral protection (tn vs. IN) is identical to characteristic of phase protection (t R vs. IR). (3) When you specify GF on MCCBs with 3 poles the terminal block is automatically fitted to connect with the external neutral CT for 3 phases 4 wires system. See terminal blocks in section 7. The Ultimate Safety Breaker page 44
14 OPERATING CHARACTERISTICS ELECTRONIC CHARACTERISTICS (STANDARD TYPE) S12SE, S12NE, S12GE Percent Rated Current I n Percent Rated Current I R I n = 12A IR (A) LTD Pickup current I R xin Standard Option LT ST INST PTA GF Note(3) NP Characteristics t R I sd tsd Ii Ip t p I g t g IN tn No at 0% x I R at 600% x IR xi R xi R 14(Max: 12 x I n) Note (1) xir 0. xin xir /0.5 Note(2) t N=tR Note (1) Ii max. = 12 x I n. (2) 1.0 x IR or 0.5 x IR can be selected. Characteristic of neutral protection (tn vs. IN) is identical to characteristic of phase protection (t R vs. IR). (3) When you specify GF on MCCBs with 3 poles the terminal block is automatically fitted to connect with the external neutral CT for 3 phases 4 wires system. See terminal blocks in section 7. page The Ultimate Safety Breaker
15 OPERATING CHARACTERISTICS ELECTRONIC CHARACTERISTICS (STANDARD TYPE) S1600SE, S1600NE SECTION 3 Percent Rated Current I n Percent Rated Current I R I n = 1600A IR (A) LTD Pickup current I R xin Standard Option Characteristics No LT t 11 R at 0% x I R at 600% x IR I sd xi R ST tsd INST Ii xi R 14(Max: 12 x I n) Note (1) Ip xir 0. PTA t p GF Note(3) NP I g t g IN tn xin xir /0.5 Note(2) t N=tR Note (1) Ii max. = 12 x I n. (2) 1.0 x IR or 0.5 x IR can be selected. Characteristic of neutral protection (tn vs. IN) is identical to characteristic of phase protection (t R vs. IR). (3) When you specify GF on MCCBs with 3 poles the terminal block is automatically fitted to connect with the external neutral CT for 3 phases 4 wires system. See terminal blocks in section 7. The Ultimate Safety Breaker page 46
16 DIMENSIONS E125NJ, S125NJ, S125GJ, S125NN With extension bars (optional) 4 Panel cutout dimensions shown give an allowance of 1.0mm or more around the handle escutcheon. H L Interpole barrier 14.5 H L Mounting hole Operating knob C L Connector plug 5.5 2(max.) 4 Front panel t2 24 M screw Preparation of conductor ø9 17(max.) max.t5 M4x0.7.5(max.) Drilling plan 132 M4x0.7 Tapped hole 17.5 Panel hinge position (hatching area) bottom view ±1 SECTION 7 Operating knob 5 14 C L 4 Front panel t2 Mounting plate (max. t3.2) 5 overlap max C L Drilling plan C L Panel cutout (Front view) R1 5 Pad lock Connector plug 5.5 2(max.) ø Stud can be turned or 90 M4X0.7 Mounting screw ø1 60 M4X0.7 Tapped hole 90 Panel cutout dimensions shown give an allowance of 1.5mm around the handle escutcheon. The Ultimate Safety Breaker page 116
17 DIMENSIONS S160NJ, S160GJ, E2NJ, S2NJ, S2GJ, S2NN With extension bars (optional) 4 Panel cutout dimensions shown give an allowance of 1.0mm or more around the handle escutcheon. SECTION 7 The Ultimate Safety Breaker page 11
18 DIMENSIONS H125NJ, L125NJ, H160NJ, L160NJ, S2NE, S2GE, S2PE, H2NJ, H2NE, L2NJ With extension bars (optional) 4 Panel cutout dimensions shown give an allowance of 1.0mm or more around the handle escutcheon. SECTION 7 The Ultimate Safety Breaker page 1
19 DIMENSIONS E0NJ, S0CJ, S0NJ, S0NE, S0GJ, S0GE, S0PJ, S0PE, S0NN With extension bars (optional) With extension bars (optional) SECTION 7 The Ultimate Safety Breaker page 122
20 DIMENSIONS E6NE, S6CE, S6GE, S6NN With extension bars (optional) SECTION 7 The Ultimate Safety Breaker page 126
21 DIMENSIONS E6NE, S6CE, S6GE, S6NN with Motor Operators With extension bars (optional) page 127 The Ultimate Safety Breaker
22 DIMENSIONS S00CJ, S00NJ, S00RJ, S00NE, S00RE, S00NN Front connected 1 51 W 13 Trip button (red) Interpole barrier Mounting hole t1 Toggle extension L t2 L M Breaker type Rated current t1 t2 L1 L2 W S00CJ, S00NJ, S00RJ, 6A S00NN 00A S00NE, S00RE 6A A M Tapped hole Rear connected Toggle extension Stud can be turned M 13 ø for accessory wiring when necessary M Tapped hole Groove for dissipating heat generated by overcurrent Note: Studs are factory installed in horizontal direction both on the line and load sides. ø Panel cutout (front view) R Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Front connected with Motor Operator M 2 13 W Interpole barrier Mounting hole Front Panel t1 L1 Manual operating handle (1) Pad lock (.5) Connector plug (19.) t2 L M Tapped hole Breaker type Rated current t1 t2 L1 L2 W S00CJ, S00NJ, 6A S00RJ, S00NN 00A S00NE, S00RE 6A A Panel cutout (front view) Panel cutout dimensions shown give an allowance of 1.5mm around motor operator. SECTION 7 Rear connected with Motor Operator 12.5 Front Panel Manual operating handle (1) Pad lock (.5) Connector plug ø for accessory wiring when necessary Stud can be turned 90 M (19.) ø ø4 M Tapped hole Panel hinge position (hatching area) (bottom view) Note: Studs are factory installed in horizontal direction both on the line and load sides. The Ultimate Safety Breaker page 12
23 DIMENSIONS S0SE, S0NE, S0NN Front connected Trip button (red) Interpole barrier Mounting hole Toggle extension M M Tapped hole Rear connected Panel cutout (front view) Toggle extension Vertical direction only M 12 ø for accessory wiring when necessary ø4 M Tapped hole Groove for dissipating heat generated by overcurrent R Panel cutout dimensions shown give an allowance of 1.0mm around the handle escutcheon. Front connected with Motor Operator M 2 13 Interpole barrier Mounting hole Front Panel Manual operating handle (1) Pad lock (.5) Connector plug (19.) M Tapped hole Panel cutout (front view) Panel cutout dimensions shown give an allowance of 1.5mm around motor operator. SECTION 7 Rear connected with Motor Operator 12.5 Front Panel Manual operating handle (1) Pad lock (.5) Connector plug 0.5 Vertical direction only ø for accessory wiring when necessary (19.) 99.5 M ø ø4 M Tapped hole Panel hinge position (hatching area) (bottom view) Note: Studs are factory installed in horizontal direction both on the line and load sides. The Ultimate Safety Breaker page 132
24 DIMENSIONS S12SE, S12NE, S12GE, S12NN Front connected Interpole barrier 13 1 Mounting hole 0 Toggle extension Trip button (red) ø M Rear connected Toggle extension Mounting plate M Insulating plate ø9 Panel cutout (front view) Soft plastic tubing ø to be provided on center pole and neutral pole of vertical terminal type for insulation ø for accessory wiring when necessary Note: Studs are factory installed in horizontal direction both on the line and load sides Panel cutout dimensions shown give an allowance of 1.5mm around the handle escutcheon. Front connected with Motor Operator 13 0 Pad lock Control circuit terminal (max.) (max.) 29 M ø9 Rear connected with Motor Operator M Mounting plate Insulating plate ø9 Panel cutout (front view) R3 11(max.) Soft plastic tubing ø to be provided on center pole and neutral pole of vertical terminal type for insulation ø for accessory wiring when necessary Note: Studs are factory installed in horizontal direction both on the line and load sides Panel cutout dimensions shown give an allowance of 1.0mm around motor operator. page 133 The Ultimate Safety Breaker
25 DIMENSIONS S1600SE, S1600NE, S1600NN Front connected Interpole barrier Trip button (red) Mounting hole Toggle extension Insulating plate Mounting angle M 139(min.) (max) ø Rear connected Panel cutout (front view) Toggle extension Mounting angle M LH ø12 14 R Insulation tube ON side Center pole and Neutral pole ( OFF side All poles ) ø9 139(min) Panel cutout dimensions shown give an allowance of 1.5mm around the handle escutcheon. Front connected with Motor Operator Control circuit terminal Pad lock Insulating plate Mounting angle L 5 11(max.) M ø (max.) 46 Rear connected with Motor Operator Panel cutout (front view) 11(max.) 4.5 Mounting angle M ø Insulation tube ON side Center pole and Neutral pole ( OFF side All poles ) ø9 139(min.) 14 4 R3 H L Panel cutout dimensions shown give an allowance of 1.0mm around motor operator. page 135 The Ultimate Safety Breaker
IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationMotor protection circuit breakers
R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationMotors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB
Motors Automation Energy Transmission & Distribution Coatings DWB Molded Case Circuit Breakers DWB Molded Case Circuit Breakers Molded Case Circuit Breakers DWB Summary Presentation 0 General Characteristics
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationK1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name
More informationThermal Magnetic Characteristics and Adjustments
Thermal Magnetic Characteristics and Adjustments - Range Operation Settings Examples Time, Current and Temperature Curves 7- Special Applications N S Range Characteristics TemBreak thermal magnetic MCCBs
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker
Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications.
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationFeeder protection relay SPAA 121 C. Product Guide
Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase
More informationCircuit Breakers Type CTI 25M, CTI 45MB
Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationCircuit Breakers, Type CTI 25M, CTI 45MB, CTI 100
MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationEarth-fault Relay SPAJ 110 C. Product Guide
Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral
More information194E FA 32 E P11 P11 6
Bulletin E IEC Load Switches, A Product Selection/Catalog Number Explanation Bulletin E Enclosed Disconnect Load Switches with R Handles (with Defeater, suitable for padlocks) E-FA Painted Steel Enclosure
More informationJ7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1
Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationCombined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide
Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices...
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationSafety Switches with Separate Actuator, Metal Housing
Selection table for safety switches SG Standard One actuating head made of metal M SR11 RC18 Thread M0x1.5 for cable glands 11-pin + PE 18-pin + PE Two contacts Four contacts NC, Standard M SR11 RC18 Two
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More informationCI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100
MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications
More informationSensitive Earth-fault Relay SPAJ 111 C. Product Guide
Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent
More informationCombined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide
Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationAdd-on Residual Current Protection PBSM MW
SG_Bestell_MV_E.qxd 25.04.2005 09:39 Seite 36 Add-on Residual Current Protection PBSM MW By combining this device with a top-quality miniature circuit breaker of type PLS. (except PLSN) a top-quality RCBO
More informationCatalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
More informationC C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description
CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationMINIATURE CIRCUIT BREAKERS LPN UP TO 63 A (10 ka)
MINIATURE CIRCUIT BREAKERS LPN UP TO 3 A (0 ka) For building, commercial and industrial installations up to 3 A 30/400 V a.c. and 0/440 V d.c. For protection of cables and conductors against overload and
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationOnline data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES
Online data sheet i10-e0454 Lock i10 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i10-e0454 Lock 6045056 The actuator has to be ordered separately. See "Accessories"
More informationMotor protection circuit breakers
Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationSIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety
SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety With Separate Actuator 3SE5 Interlock Switches Overview SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Position switches with separate actuator
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationWEG Contactors - CWM and CWME Series
Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.
More informationDescription. Installation. Power supply
Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of
More informationATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase
Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short
More informationOrdering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R
13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description ngle, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only hydraulically delayed switching characteristics
More informationDatasheet - AZ 16-03ZVRK
23.07.2015-02:06:20h Datasheet - AZ 16-03ZVRK Safety switch with separate actuator / AZ 16 Preferred typ Thermoplastic enclosure Double-insulated Large wiring compartment 52 mm x 90 mm x 30 mm Multiple
More informationHinged safety switches, Palladio line
Hinged safety switches, Palladio line Selection diagram CONTACT BLOCKS 0C 0F 0M C F M snap action snap action snap action C F M CABLE AND CONNECTORS S A P KSM KAM Cable output Cable output M connector
More informationBasic Efficiency. NH Fuse-Bases 3-pole. NH Fuse-Bases up to 1500 V. NH Fuse-Bases 1-pole. NH Fuse-Bases, SILAS
Basic Efficiency up to 1500 V 1-pole 3-pole, SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 58 Accessories 60 Technical Data see page 63 NU System The EFEN successfully
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationSafety switches with separate actuator
4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC
More informationMulti 9 System Catalog
Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7
More information