EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
|
|
- Marshall Fitzgerald
- 5 years ago
- Views:
Transcription
1 EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL EZTAG Manual_Layout.indd 8//06 5:8:0
2 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk screws x Diode and x Capacitor Optional Accessories EVBPSBB Lock Power Supply EV-EXIT Push to Release EV-EBG Emergency Release EV-ML-50/500XT Electro-magnetic Lock ENTERD Electric Lock EZTAG Manual_Layout.indd 8//06 5:8:07
3 Contents Installation... EZTAG Wiring Example... 5 EZTAG Wiring Example... 5 Advanced Guide How to set-up Access Pin... 6 How to set-up Access Tags... 6 Deleting Access Pin or Tag... 7 Changing Pin... 7 Clear all Pin and Tag Data... 8 Default to Factory Settings... 8 Lock Output Operating Time... 9 Enable Door Bell Facility... 9 Enable Tamper Alarm facility... 0 Access Pin for Lock Output... 0 Deleting Access Pin for Lock... Lock Output Operating Time for Lock Output... System setup record... User Guide... Technical Specification... EZTAG Manual_Layout.indd 8//06 5:8:07
4 Installation Release hex screw from the bottom of the keypad (Side View) Push the keypad up to release from mount plate Thread system cable through the cable entry hole then make the system connections (as per the wiring diagram), mount the bracket to the surface and slide the keypad to the mountplate, re-fit the hex screw to secure into position. Note: if using more than one keypad, ensure that the keypads are mounted a minimum 85cm apart EZTAG Manual_Layout.indd 8//06 5:8:07
5 EZTAG Wiring Example LEDs Capacitor for Electro-magnetic lock Diode for Electronic Lock Electro-magnetic lock _ + Electronic lock Lock -release time Red Black Green Purple Grey Pink NC + _ + _ N.C for Electro-magnetic lock N.O for Electronic lock Tag Reader EZTAG Wiring Example LEDs Red Black Green Purple Blue Grey Orange Pink Green/White N.O Purple/White COM Blue/White N.C Yellow White Tag Reader Input DC: +V - +V or Input AC: V - V N.O COM P.b for Lock (N.O) Output for Lock (Volt-free) N.C + _ Output for Lock (Volt-free) Push button for Lock (N.O) Speaker connection for door bell facility (8Ω 0.5w recommended) 5 EZTAG Manual_Layout.indd 5 8//06 5:8:09
6 How to set-up Access Pin 9 0 a starting location number Double 5???? a digit pin ( not be used) 6 How to set-up Access Tags a unused location number* ??? number of tags to be registered 6 Present the tag with the lowest serial number 7 All other batch tags will auto register To end programming *Each tag will use up a location number 6 EZTAG Manual_Layout.indd 6 8//06 5:8:09
7 Deleting Access Pin or Tag the location number of tag/pin To delete Changing Pin???? new digit programming pin???? Re-enter new digit programming pin 5 Note; To access keypad s programming mode, the digit programming code is entered in twice 7 EZTAG Manual_Layout.indd 7 8//06 5:8:09
8 Clear all Pin and Tag Data Default to Factory Settings EZTAG Manual_Layout.indd 8 8//06 5:8:09
9 Lock Output Operating Time number of seconds 00-99?? Enable Door Bell Facility 0 To enable 0 To disable Becomes the door bell push in normal mode 9 EZTAG Manual_Layout.indd 9 8//06 5:8:09
10 Enable Tamper Alarm facility 6 0 To enable 0 To disable Tamper alarm activates the keypad s internal buzzer and door bell output if the light sensor is exposed Access Pin for Lock Output 9 0 an unused location number Double 5???? a digit pin ( should not be used) 6 0 EZTAG Manual_Layout.indd 0 8//06 5:8:09
11 Deleting Access Pin for Lock the location number of pin To delete 5 Lock Output Operating Time for Lock Output 5 number of seconds 00-99?? EZTAG Manual_Layout.indd 8//06 5:8:0
12 To assist in future programming, it is recommended that a record is made of the system setup. System Location ( ) Tag Serial Tag Owner Notes EZTAG Manual_Layout.indd 8//06 5:8:0
13 System Location ( ) Tag Serial Tag Owner Notes EZTAG Manual_Layout.indd 8//06 5:8:0
14 User Guide To release Lock (A) a programmed Access Pin number (B) Present a registered tag To access programming mode Technical Specification DC input - volts AC input - volts Standby current 80ma Operating current (without lock) 0ma Working temperature -0c to +50c Reader frequency 5KHz IP rating 65 Dimension 50 x x mm EZTAG Manual_Layout.indd 8//06 5:8:0
15 EZTAG Manual_Layout.indd 5 8//06 5:8:0 5
16 K6 Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN Telephone: Fax: info@espuk.com EZTAG Manual_Layout.indd 6 8//06 5:8:0
EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x
More informationEZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL
EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out
More informationAPWIFIDS WI-FI DOOR STATION
APWIFIDS WI-FI DOOR STATION www.espuk.com J2474 ESP Instruction Manual APWIFIDS.indd 1 15/03/2017 11:20:14 System Overview Sunshield Optional accessories: IR LED Camera lens EVBPSBB Lock power supply Speaker
More informationD O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R
D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R Table of contents Planning and installing the Enterview VX............................ 3 Wiring Diagram.....................................................
More informationA P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L. w w w. e s p u k. c o m
APKITKP Manual.qxp_Layout 1 28/01/2016 11:45 Page 1 A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L w w w. e s p u k. c o m APKITKP Manual.qxp_Layout 1 28/01/2016
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationInstruction Manual. Vogue. Security. Technology. Innovation 2013-V01
Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationW3-H Waterproof Keypad/Reader/Controller
W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More informationW3-M. Metal waterproof standalone access control/reader. User Manual
W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,
More informationWiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader
Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader www.grantsautomation.com.au grant@grantsautomation.com.au Wiring Diagrams for MAW6 Digital Keypad For Pedestrian
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More informationVIDI-AC-2CS Access Controller/ Reader
VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationStand-alone Proximity Access Control
Stand-alone Proximity Access Control User Manual INTRODUCTION VIDI-AC-1C is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. It uses
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More informationInstallation and User Manual
S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More information-DTZ001- Stand-Alone Proximity Access Control. User Manual
-DTZ001- Stand-Alone Proximity Access Control User Manual INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users,
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationTEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018
TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT
More informationUser Manual. Split access control with intelligent secured power supply.
User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.
More informationRBR-SB-KTZ001 LAR 2. User Manual
RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.
More informationACCESS CONTROL SYSTEM
ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationW Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2
W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor
More information_ Access control SISTEMAS DE SEGURIDAD
_ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationInstalling Keypad and Backplate
Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using
More informationHSY-S209 EM Metal waterproof access control system User Manual
HSY-S209 EM Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1. Product Profile The product is Contact-less inductive card Metal Password Access Controller,
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationGV-Card Reader. User s Manual
GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights
More informationBC Digital Keypad. User Manual
BC2200 Digital Keypad User Manual Name Digital Keypad BC2200 User manual Screw driver Rubber bungs Self tapping screws Diode 1. Packing List Quantity Remarks 1 1 1 4 Φ6mm 28 mm, used for fixing 4 Φ4mm
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More informationStandalone Access Control
Standalone Access Control BELL_A BELL_B D0 D1 D_in(LED) Open (BZ) COM ALARM- Light Green Pink Red Black Green White Brown Yellow Blue Purple Orange Grey Door Bell DC 12V Power Green White Reader Red Black
More informationPartizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating
1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without
More informationQuick Start Guide. GV-CS1320 Camera Access Controller
Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.
More informationContents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection
Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationSL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.
SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming
More informationCM-500 SK 500 USER CODES KEYPAD
CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage
More informationCV-945 Stand-Alone Biometric Reader. Installation Instructions
CV-945 Stand-Alone Biometric Reader Installation Instructions Contents 1.0 Introduction... 03 2.0 Mounting... 03 3.0 Specifications... 04 4.0 Application Diagram... 04 5.0 Wiring... 05 6.0 Recommended
More informationRevision Date: 02 Mar 2018
KAS Bluetooth Locks HOMES AIRBNB OFFICES SHARED SPACE Revision Date: 02 Mar 2018 COPYRIGHT: Information in this document is subject to change without further notice. No part of this document can be reproduced
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationCC Series metal access control Manual
CC Series metal access control Manual 1.Description CC Series is a standalone for two doors, support card, pin, card+pin access way. It is with 2 relays to control 2 doors and supports up to 2000 users
More informationWaterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)
Touch & No Touch Exit Buttons s Infra-Red No Touch Exit Buttons ADB-11-CO (No Touch)/ ADB-13-CO (Hand icon) - 86x86x39mm - Sensing distance: 0.1-15cm - Installation: use with 86*86 back box ADB-12-CO (No
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationWELCOME. For customer support or any inquiries, please visit our web site at or contact us at
WELCOME Congratulations on purchasing the GBF Smart Four Wire Intercom System. Our factory engineers were the first to enable multiple security cameras being monitored through a smart mobile device and
More informationEcoEntry. RFID Proximity Access Control System. User Guide. Revision 2
EcoEntry RFID Proximity Access Control System User Guide Revision 2 Introduction The ecoentry door access system allows the user to open the door using a keyfob, password, or keyfob plus password. Specification
More informationACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox
standalone ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox ACT 5e prox 2R.indd 1 19/02/2016 17:05:06 ACTstandalone Robust and Reliable. 1 ACT 5e prox 2R.indd 2 19/02/2016
More informationFTK5 PROXIMITY KEYPAD
FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More informationFast operation of IP Villa System V 1.0
Fast operation of IP Villa System V 1.0 Contents 1 System Structure... 3 2 Operation Steps... 3 2.1 VTO WEB Config... 3 2.2 Main VTH Setup... 4 3 Group call Settings... 5 3.1 VTO web config... 5 3.2 Sub-
More informationEN FULL DETAILS SKB. Vandal Resistant keypad - Full Details
EN FULL DETAILS SKB Vandal Resistant keypad - Full Details WARNINGS Carry out the installation by carefully following the instructions provided by the manufacturer in accordance with the current standards.
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationFingerprint Identification Proximity Reader. Quick Installation Guide
Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor
More informationWireless Key fob, Key pad & Receiver Range
Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC
More information1. Product Specification
1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationPRODUCT GUIDE FT-DC3-HC DOCUMENT NUMBER REVISION DATE
PRODUCT GUIDE DOCUMENT NUMBER REVISION DATE 20170822 NOTICE The manufacturer will accept no responsability for any electrical damage resulting from improper installation of this product, be that either
More informationInstallation & User Manual V1.0
Other products from GSD standalone products GSD also offers fully functional standalone door controls for less complex door management. This attractive design, with modern aesthestics, will complement
More informationQUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint
More informationQuick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER
MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More informationlumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO
Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS Flat wall mounted lighting controller Universal mounting plate compatible with any electrical backbox MINI-USB connection for software programming
More informationVIS-3200 / VIS-3201 User Manual
2.4GHz Indoor Black Wireless Exit Button Receiver Keypad / Reader Access Control 500 Users Range of 50 Feet Delay and On/Off Toggle Mode Battery Operated Standalone No Software 1 VIS-3200 / VIS-3201 User
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationC e l l C O M. G S M I n t e r c o m
C e l l C O M G S M I n t e r c o m Call fixed line phone GSM SIGNAL Call mobile cell phone Accepts any GSM SIM card. Quad band modem. 850 / 900 / 1800 / 1900 MHz Calls up to 3 numbers in sequence GSM
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More informationB100-SA Standalone Biometric Reader
EN B100-SA Standalone Biometric Reader User Manual v.b1 Contents 1.0 INTRODUCTION 2.0 MOUNTING 3.0 SPECIFICATIONS......... 3 3 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED SWIPING TECHNIQUE...
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationLab 5: Access Control Training Station
Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand
More informationWith INTRATONE, you can easily secure all kinds of access points. You choose the management mode
With INTRATONE, you can easily secure all kinds of access points (Car parks, isolated doors, pedestrian gates, etc.) You choose the management mode REAL-TIME and REMOTE USING GSM READ/WRITE MODE How does
More informationIP Speaker System. Users Guide
ii3-ess IP Speaker System Users Guide ESS User Manual This page intentionally left blank 2 ESS User Manual Table of Contents Overview... 1 Specifications... 2 25/70 Volt Lines... 3 Speaker Configurations...
More informationInstallation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B
Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its
More informationAR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers
AR-727HB-RAY AR-716E-RAY EAR-727HB-RAY Series of Controllers Installation and Programming Guide AR-716E-RAY EAR-727HB-RAY AR-727HB-RAY 10th August 2011 Version 1.00 Southern Office: Raytel House Brook
More informationZAVIO Outdoor IR Mini Dome. Quick Installation Guide
ZAVIO Outdoor IR Mini Dome Quick Installation Guide 0 Quick Installation Guide Please follow the installation steps below to set up your IP Camera. Check the package contents with the list below. See P.1
More informationSOYAL AR-725E-M / AR-725E / AR-725X V Contents AR-725E-M. Installation AR-725E-M AR-725E AR-725X. Parts Description AR-725E AR-725X
SOYAL ACCESS CONTROL SYSTEM AR-E-M / AR-E / AR- 0909 Contents AR-E-M Products User Guide Terminal Cables Tools P P P P c x d x A. B. C. D. P P P P AR-E Products User Guide Terminal Cables Tools P P P P
More informationTOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:
ins-016 160499 TOUCHLOCK compact 100-050 TOUCHLOCK compact kit Instructions for the following: 526-886 TOUCHLOCK compact keypad 100-050 TOUCHLOCK compact kit Master code: Document Contents About this product...2
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationQuick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0
Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7
More informationSafety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate
www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection
More information9212i INSTALLATION. Stand-Alone Keypad. Instructions
INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad
More information