3RA13, 3RA14 Contactor Assemblies
|
|
- Norah Hudson
- 6 years ago
- Views:
Transcription
1 RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock (for voltages > 00 V, a dead interval of 0 ms on reversing must be taken into account) Sizes S00 to S As components for customer assembly. There is also a range of accessories (auxiliary switch blocks, surge suppressors, etc.) that must be ordered separately. For overload relays for motor protection, see "SIRIUS Overload Relays". The RA1 contactor assemblies have screw connections and are suitable for screwing or snapping onto mm standard mounting rails. Complete units The fully wired reversing contactor assemblies are suitable for use in any climate. They are finger-safe according to EN 027. The contactor assemblies consist of 2 with the same power, with one NC contact in the basic unit. The are mechanically and electrically interlocked (NC contact interlock). For motor protection, either RU11 overload relays for direct mounting or individual mounting or thermistor motor protection tripping units must be ordered separately. Components for customer assembly Installation kits for all sizes are available for customer assembly of reversing contactor assemblies. Contactors, overload relays, the mechanical interlock (as of size S0) and for momentary-contact operation auxiliary switch blocks for latching must be ordered separately. Rated data AC-2 and AC- for AC 0 Hz 00 V Rating kw Size Contactor Mechanical current I e interlock 1) A 1) Can be mounted onto the. 2) Laterally mountable with one auxiliary contact. ) Laterally mountable without auxiliary contact. ) Interlock can only be ordered with installation kit. ) Installation kit contains: mechanical interlock; connecting clips for 2 ; wiring connectors on the top and bottom. Mechanical interlock 2) Mechanical Installation kit Fully wired and tested interlock ) contactor assemblies 7 S00 RT ) RA19 1-2A ) RA1 1-8XB RT10 1 RA1 1-8XB RT10 17 RA1 17-8XB S0 RT10 2 RA19 2-1A RA19 2-2B -- RA19 2-2A ) RA1 2-8XB RT10 2 RA1 2-8XB RT10 2 RA1 2-8XB S2 RT10 RA19 2-1A RA19 2-2B -- RA19-2A 7) RA1-8XB RT10 RA1-8XB RT10 RA1-8XB S RT10 RA19 2-1A RA19 2-2B -- RA19-2A 7) RA1-8XB RT10 RA1-8XB RT10 RA1-8XB S RT RA19-2A RA19-2A 8) RT RT S10 RT RA19-2A RA19-2A 8) -- 2 RT RT S RT RA19-2A RA19 7-2A 8) RT ) Installation kit contains: wiring connectors on the top and bottom. 7) Installation kit contains: 2 connecting clips for ; wiring connectors on the top and bottom. 8) Installation kit contains: wiring module on the top and bottom. /8 Siemens LV 1 200
2 RA1, RA Contactor Assemblies RA1 complete units,... kw Selection and ordering data Size S00. kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and Rated control DT supply voltage U 1) s Fully wired and tested contactor assemblies 2) Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation, 0/0 Hz AC A RA1 1-8XB0-1AB0 1 1 unit AC A RA1 1-8XB0-1AF0 1 1 unit AC } RA1 1-8XB0-1AP0 1 1 unit AC A RA1 1-8XB0-1AB0 1 1 unit AC A RA1 1-8XB0-1AF0 1 1 unit AC } RA1 1-8XB0-1AP0 1 1 unit AC A RA1 17-8XB0-1AB0 1 1 unit AC A RA1 17-8XB0-1AF0 1 1 unit AC } RA1 17-8XB0-1AP0 1 1 unit DC operation 1) Coil operating range at 0 Hz: x U s ; at 0 Hz: x U s DC } RA1 1-8XB0-1BB 1 1 unit DC } RA1 1-8XB0-1BB 1 1 unit ) The integrated in the contactor assemblies have no unassigned auxiliary contacts. Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: NSB Accessories Page Individual parts Page K1 K2 1 1 Solder pin adapters (auxiliary switch block according to EN 000 must be used) Surge suppressors RT19 1-KA1 RH RT /2 /110 /119, /0 1) RT10 1 with one NC contact in the basic unit are required for the electrical interlock. Contactors, kw Contactors, kw Contactors,. kw Installation kit The installation kit contains: RT10 1 RT10 1 RT10 17 RA19 1-2A RT10 1 RT10 1 RT10 17 Mechanical interlock 2 connecting clips for 2 Wiring connectors on the top and bottom for connecting the main conducting paths, electrical interlock included 1), interruptible (NC contact interlock) / / / / Siemens LV /9
3 RA1, RA Contactor Assemblies RA1 complete units,... kw Size S0 11 kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and 1) Coil operating range at 0 Hz: x U s ; at 0 Hz: x U s. Rated control DT supply voltage 1) U s Fully wired and tested contactor assemblies Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation, 0/0 Hz AC A RA1 2-8XB0-1AC2 1 1 unit AC A RA1 2-8XB0-1AG2 1 1 unit AC } RA1 2-8XB0-1AL2 1 1 unit AC A RA1 2-8XB0-1AC2 1 1 unit AC A RA1 2-8XB0-1AG2 1 1 unit AC } RA1 2-8XB0-1AL2 1 1 unit AC A RA1 2-8XB0-1AC2 1 1 unit AC A RA1 2-8XB0-1AG2 1 1 unit AC A RA1 2-8XB0-1AL2 1 1 unit DC operation DC } RA1 2-8XB0-1BB 1 1 unit DC A RA1 2-8XB0-1BB 1 1 unit DC A RA1 2-8XB0-1BB 1 1 unit Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: NSB000 The connecting leads are not shown. Accessories Page Individual parts Page K1 K2 1 1 Surge suppressors RA19 2-1A RH CA.. RH EA.. RT / /1 /1 /119 Contactors,. kw Contactors, 7. kw Contactors, 11 kw RT10 2 RT10 2 RT10 2 RT10 2 RT10 2 RT10 2 / / / Installation kit RA19 2-2B RA19 2-2A / / The installation kit contains wiring connectors on the top and bottom (they also form the mechanical connection between the ). /0 Siemens LV 1 200
4 RA1, RA Contactor Assemblies RA1 complete units,... kw Size S2 22 kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and 1) Coil operating range at 0 Hz: x U s ; at 0 Hz: x U s. Rated control DT supply voltage 1) U s Fully wired and tested contactor assemblies Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation, 0/0 Hz AC A RA1-8XB0-1AC2 1 1 unit AC A RA1-8XB0-1AG2 1 1 unit AC A RA1-8XB0-1AL2 1 1 unit AC A RA1-8XB0-1AC2 1 1 unit AC A RA1-8XB0-1AG2 1 1 unit AC A RA1-8XB0-1AL2 1 1 unit AC B RA1-8XB0-1AC2 1 1 unit AC B RA1-8XB0-1AG2 1 1 unit AC A RA1-8XB0-1AL2 1 1 unit DC operation DC A RA1-8XB0-1BB 1 1 unit DC A RA1-8XB0-1BB 1 1 unit DC A RA1-8XB0-1BB 1 1 unit 101. Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: NSB001 The connecting leads are not shown. Accessories Page Individual parts Page K1 K2 1 1 Surge suppressors RA19 2-1A RH CA.. RH EA.. RT RT / /1 /1 /119 Contactors, 1 kw Contactors, 18. kw Contactors, 22 kw Installation kit The installation kit contains: RT10 RT10 RT10 RA19 2-2B RA19-2A RT10 RT10 RT10 /1 /1 /1 / / 2 connecting clips for 2 with a clearance of 10 mm Wiring connectors on the top and bottom for connecting the main conducting paths Siemens LV /1
5 RA1, RA Contactor Assemblies RA1 complete units,... kw Size S kw Rated data AC-2 and AC- current I e Ratings of induction motors at 0 Hz and 1) Coil operating range at 0 Hz: x U s ; at 0 Hz: x U s. Rated control DT supply voltage 1) U s Fully wired and tested contactor assemblies Price 00 V 20 V 00 V 00 V 90 V A kw kw kw kw V kg AC operation at 0/0 Hz AC B RA1-8XB0-1AC2 1 1 unit AC B RA1-8XB0-1AG2 1 1 unit AC B RA1-8XB0-1AL2 1 1 unit AC B RA1-8XB0-1AC2 1 1 unit AC B RA1-8XB0-1AG2 1 1 unit AC B RA1-8XB0-1AL2 1 1 unit AC B RA1-8XB0-1AC2 1 1 unit AC B RA1-8XB0-1AG2 1 1 unit AC B RA1-8XB0-1AL2 1 1 unit DC operation DC B RA1-8XB0-1BB 1 1 unit DC B RA1-8XB0-1BB 1 1 unit DC B RA1-8XB0-1BB 1 1 unit Mountable accessories (to be ordered separately): The fully wired and tested contactor assembly includes the following components: NSB002 The connecting leads are not shown. Accessories Page Individual parts Page K1 K2 1 1 Surge suppressors RA19 2-1A RH CA.. RH EA.. RT RT / /1 /1 /119 Contactors, 0 kw Contactors, 7 kw Contactors, kw Installation kit The installation kit contains: RT10 RT10 RT10 RA19 2-2B RA19-2A RT10 RT10 RT10 /18 /18 /18 / / 2 connecting clips for 2 with a clearance of 10 mm Wiring connectors on the top and bottom for connecting the main conducting paths /2 Siemens LV 1 200
6 RA1, RA Contactor Assemblies Components for customer assembly Selection and ordering data For Type Mechanical interlocks RA19 2-1A mounted onto 2 RA19-2A RA19-2C Coil repeat terminals RA19 2-B Base plates RT10 2 RT10 RT10 RT1 2 RT1 RT1 RT10 2 RT10 RT10 RT1 2 RT1. RT1. 7 RT10.-A with RT10 RT10 RT10 1) Can also be used for -pole with sizes S2 and S. 2) Can also be used for size S0 -pole. Size Version DT Price S0 S2 S S0 S2 S S0 S S10 S S with S For mounting 1) Each with one auxiliary contact (1 NC contact) per contactor (can only be used to connect which are not more than 1 size larger or smaller. The mounting depth of the smaller contactor has to be adapted.) For mounting to the 2) To with sizes S0 to S (for of the same size) Note: Size S0: Wiring connectors must be mounted first Sizes S2 and S: Use RA19 2-2C mechanical connectors For mounting Without auxiliary contacts; size S, S10 and S can be interlocked with each other as required; no adaptation of mounting depth is necessary. Contactor clearance 10 mm. kg } RA19 2-2B 1 1 unit } RA19 2-1A 1 1 unit } RA19-2A 1 1 unit Adapter, ly mountable, for mechanical interlocking of contactor S (only for AC operation) with contactor S using RA19-2A locking device (must be ordered separately) incl. connecting clips A RA19-2C 1 1 unit S2, S For the coil connectors A1 and A2 for reversing starters (contactor sizes S2 and S). 2 x A1 and 1 x A2 required per assembly. (1 set contains 10 x A1 and x A2) B RA19 2-B 1 1 set RT10 S For customer assembly of B RA19 2-2A 1 1 unit RT1. S10 reversing contactor B RA19 2-2A 1 1 unit RT1. 7 S assemblies B RA A 1 1 unit Siemens LV /
7 RA1, RA Contactor Assemblies Components for customer assembly For Size Version DT Price kg Type Installation kits for making -pole contactor assemblies RT10 1 S00 The installation kit contains: } RA19 1-2A 1 1 set mechanical interlock 2 connecting clips for 2 RA19 1-2A wiring connectors on the top and bottom RT10 2 S0 The installation kit contains: wiring connectors on the top and bottom } RA19 2-2A 1 1 set RA19 2-2A RT10 S2 The installation kit contains: 2 connecting clips for 2 wiring connectors on the top and bottom } RA19-2A 1 1 set RA19-2A RT10 S The installation kit contains: 2 connecting clips for 2 wiring connectors on the top and bottom } RA19-2A 1 1 set RA19-2A RT10 S The installation kit contains: A RA19-2A 1 1 set RT1. S10 wiring connectors on the A RA19-2A 1 1 set RT1. 7 S top and bottom A RA19 7-2A 1 1 set / Siemens LV 1 200
8 RA1, RA Contactor Assemblies Components for customer assembly Wiring connectors Size For Contactor clearance Version DT Price Type mm kg RT10 1 S00-S00 0 Top (in-phase) } RA19 1-D 1 unit Bottom (phase reversal) } RA19 1-E 1 unit RT10 2 S0-S0 0 Top (in-phase) } RA19 2-D 1 unit and and Bottom (phase } RA19 2-E 1 unit S0-S0 10 reversal) RT10 S2-S2 10 Top (in-phase) } RA19 -D 1 1 unit Bottom (phase } RA19 -E 1 1 unit reversal) RT10 S-S 10 Top (in-phase) } RA19 -D 1 1 unit Bottom (phase } RA19 -E 1 1 unit reversal) RT10 S-S 10 Top (in-phase) A RA19 -D 1 1 set RT10 S10-S10 10 Top (phase reversal) B RA19 -D 1 1 set Size For Contactor clearance Interlocking Version DT Price Type mm kg Mechanical connectors 1 pack = 10 sets for 10 assemblies RT1. 1 1) S00-S00 0 Laterally For and mountable -pole } RA19-2H 1 10 sets RA19-2H RA C RT1. 2 S0-S0 0 Mountable 10 2) on RT1. RT1. S2-S2 S-S Laterally mountable 0 Mountable on For and -pole For -pole } RA C 1 10 sets } RT D 1 10 sets } RA19 2-2C 1 10 sets RA19 2-2C RT1. RT1. RT1. S2-S2 S-S S-S 10 Laterally For -pole mountable } RA19 2-2D 1 10 sets RA19 2-2D RT1. S2-S2 10 Laterally For -pole mountable } RA19 2-2G 1 10 sets RA19 2-2G RT1. S-S 10 Laterally For -pole mountable } RA19 2-2G 1 10 sets RA19 2-2G 1) This pack contains 10 additional interlocks. 2) The connector function can be fulfilled with the wiring connectors for size S0, a contactor clearance of 10 mm and a interlock. Siemens LV /
Contactors and Contactor Assemblies
SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during
More information3RT, 3TB, 3TF Contactors for Switching Motors
RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically
More informationIEC Contactors. Auxiliary Contact Blocks GENERAL
IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount
More informationContactors and Contactor Assemblies
RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.
More informationsirius Switching. Protecting. Starting. SIRIUS Product Overview
sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar
More informationContactors and Contactor Assemblies
Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500
More informationIEC Power Control Contactors and Contactor Assemblies
IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,
More informationControls Contactors and Contactor Assemblies
Dimensional drawings RT10 contactors, -pole RT10 1 contactors, size S00 with surge suppressor, auxiliary switch block and mounted overload relay 4, 8,6 67 99 106 9 ) Lateral distance to grounded components
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More informationLoad Feeders, Motor Starters and Soft Starters
Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationClick 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.
Click 'n' Go: SIRIUS Modular System SIRIUS Highly flexible system-based switching, protecting and starting. Answers for industry. s Everything for the electrical cabinet: SIRIUS Modular System. Contents
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationSiemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.
Siemens AG 00 Highly flexible system-based switching, protecting and starting. SIRIUS Modular System SIRIUS Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Press Shop
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More informationSystem-based switching, protecting, starting. SIRIUS Modular System. sirius
System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,
More informationMini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)
K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationFor Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.
For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Starters for Use in the Control Cabinet rice groups G W, 4O, 30, 4, 50, 60, 4B, 4D, 4E, 4L, 4C, 4D, 4F, 47, 4N, 5K, 5K, 5N, 764, 5, 6 / Introduction SIRIUS 3RA load feeders /4 General
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationTeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters
Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp
More informationIndustrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,
Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More information4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data
Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed
More informationSIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED
SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment
More informationSolid-State Switching Devices
Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationAllen-Bradley Drives
Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact
More informationSIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.
For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,
More informationSIRIUS Modular System
SIRIUS Modular System Highly flexible system-based switching, protecting and starting siemens.com/sirius Answers for industry. Everything for the electrical cabinet: SIRIUS Modular System. Contents SIRIUS
More informationLarge Frame IEC Contactors
Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting
More informationTable of Specifications
Table of Specifications Midi-Contactors 3-Pole Magnetic Contactors Terminal type CC9 CC12 CC18 CC22 CC32 CC40 Screw Only Screw Only GUA1, GUA2, GUA4 GUA-1 GUA-2, GUA-4 GUA-1 GUA-2, GUA-4 GT Type Thermal
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationAllen-Bradley Bulletin 100 Contactors
Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More information3RP, 7PV Timing Relays
3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN
More informationFile E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany
File E156943 Project 00ME17885 December 18, 2000 REPORT on COMBINATION CONTROLLERS Siemens AG Amberg, Germany Copyright 2000 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the
More informationSIRIUS modular system
SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop
More informationSIRIUS modular system
SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop
More informationFast Bus Busbar System
Busbar System Industrial Controls Product Catalog 2017 Section c o n t e n t s Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming
More informationFast Bus Fast Bus Busbar System
Fast Bus Busbar System Contents Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationonlinecomponents.com
ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary
More informationSIRIUS 3RB2 Solid-State Overload Relays
SIRIUS 3RB2 Solid-State 3RB20, 3RB21 for standard applications Overview 1 2 2 $ Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG GERMANY This is to certify that representative samples of Motor Controllers, Magnetic (See following pages for additional
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationIndustrial controls SIRIUS Innovations Star-Delta (Wye-Delta) Combination Assembly and Wiring Application description June 2010
Cover Sheet Industrial controls SIRIUS Innovations Star-Delta (Wye-Delta) Combination Assembly and Wiring Application description June 2010 Applications & Tools Answers for industry. Industry Automation
More informationK-Line Mini - Contactors, Overload Relays and Accessories
K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................
More informationSIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link
SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications siemens.com/sirius Answers for industry. SIRIUS 3RB24
More informationSimply on. Simply off. Day and Night. sirius SWITCHING
Simply on. Simply off. Day and Night. sirius SWITCHING SIRIUS-Funktionen im Überblick Switching Protecting Starting Monitoring and controlling Detecting Commanding and signaling Supplying Engineering SIRIUS
More informationMolded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...
Circuit Breakers, 09/054 Moeller Electric Corporation Auxiliary Contacts for Type Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. Standard auxiliary
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationTeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor
s TeSys D, -pole changeover contactor pairs for control in category AC-, 0 A Pre-assembled. Pre-wired power connections. For connection by spring terminals. Utilisation category AC- Non-inductive loads
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG
More informationOverload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview
Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting
More informationSR60 Busbar System 2/1. 2/2 Busbar routing. 2/3 Mounting components. 2/6 Accessories
SR60 Busbar System 2 2/2 Busbar routing 2/3 Mounting components 2/6 Accessories 2/1 SR60 Busbar System Busbar routing SR60 Busbar System Dimensions Order No. Price PG Weight PS*/ W x H x D mm mm mm 1 item
More informationMini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors
More informationContactors and Overload relays
Comprehensive Catalogue 2006 Super Solution Contactors and Overload relays The Challenges and Growth achieved by LG will continue with New Will of LS Industrial Systems. New Name of LG Industrial Systems,
More informationIndustrial Controls Product Catalog 2017
Industrial Controls Product Catalog 2017 SIRIUS Section c o n t e n t s Thermal overload relays Solid state overload relays OVERLOAD RU21 overload relays up to 100 A with screw connection, CLASS 10 Page
More informationAllen-Bradley 700-K40E-DJ
Bulletin Overview/Product Selection Bulletin Miniature Control Relays IEC compact industrial relay IPX Finger Protection Bifurcated contacts for low-level signals Optional integrated coil protection diode
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationCS7 Industrial Control Relays
CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationEnclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1
KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationSIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link
Integrated Motor Protection for High-Feature Applications SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS Overload Relays www.siemens.com/sirius SIRIUS 3RB24
More information3RA6 Fuseless Compact Starters
3RA Fuseless Compact Starters Catalog News LV 1 N January 2008 www.siemens.com/compactstarter Kataloge rund um SIRIUS SENTRON SIVACON Ausgabe 2008 Siemens AG 2008 Related catalogs Contents Low-Voltage
More informationSiemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0
More informationSwitching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls
SIRIUS Modular System. The perfect combination Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls Everything for the control cabinet: the SIRIUS
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name
More informationXT IEC Power Control Contactors, Starters and Overload Relays
May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........
More informationTeSys contactors From 115 to 2750 A
Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,
More informationIEC Power Control Overload Relays
IEC Power Control Overload Relays Contents Contents Thermal overload relays Solid state overload relays 3RU21 overload relays up to 100 A with screw connection, CLASS 10 Page Selection and ordering data
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase
Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short
More informationTable 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.
IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......
More informationSiemens.com/industrial-controls
SIRIUS Industrial Controls List 2018 Siemens.com/industrial-controls List of Contents Motor Control and Protection Soft Starters Motor Management - Simocode Monitoring Relays Commanding and Signaling Devices
More informationATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate
Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationControl relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO
Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2234992 (012730_C_000) Date ssued: 2017-08-04 ssued to: Siemens AG DF CP R&D C 2 Werner-von-Siemens-Strasse 48 Amberg, 92224 GERMANY The products listed below are
More informationSwitchgear 1.1. CONTACTORS - Installation. Page 1.2. Page 1.2. CONTACTORS - Mini. Page POLE RELAY. Page 1.3. CONTACTORS - Standard Frame
Switchgear CONTACTORS Installation Page 1.2 CONTACTORS Mini Page 1.2 4 POLE RELAY Page 1.2 CONTACTORS Standard Frame Page 1.3 CONTACTORS Large Frame Page 1.4 OVERLOADS Thermal Page 1.5 CONTROL RELAYS Industrial
More informationATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More informationEC Declaration of Conformity
The undersigned, representing the manufacturer Rockwell Automation uchserstr. 7 CH-5000 Aarau, Switzerland herewith declare that the Products Product identification (brand and catalogue number/part number):
More information0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27
ccessories Field Installable C7 Top (Front) Mount uxiliary Contact Blocks Contact Block NO NC 0 2 Contact rrangement 5161 5262 with... Standard Contacts Catalog Number Price Bifurcated Contacts Catalog
More informationSIRIUS - SIRIUS 3RA28
Industrial Controls Switching Devices SIRIUS - SIRIUS 3RA28 Function modules for mounting on 3RT2 contactors Gerätehandbuch Manual Edition 09/2016 siemens.com SIRIUS - SIRIUS 3RA28 function modules for
More informationSafety Systems Safety Integrated
3SE2 / SE3 Molded plastic /metal enclosure with separate actuator Application Safety interlock switches with separate actuator are used where the position of doors, covers or safety screens must be monitored
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationStandards and approvals
2 SIRIUS controls contactors and contactor assemblies 4 SIRIUS controls solid-state switching devices 4 SIRIUS protective devices 8 SIRIUS load feeders and compact starter 12 SIRIUS Circuit Breaker 12
More informationControl, Timing + Ice Cube Relays
... 2 Technical Information... 14 CS8... 18 Technical Information... 21 RZ7-FS Electronic... 24 Technical Information... 34 RZ7-FE Electronic... 36 Technical Information... 42 Relpol Ice Cube Relays R2/R4
More information