GE Security, unrivalled expertise in Access Control

Size: px
Start display at page:

Download "GE Security, unrivalled expertise in Access Control"

Transcription

1 In this catalogue you will find a wide range of Access Control equipment from GE Security. GE Security is a global technology leader dedicated to supporting the needs of the rapidly growing electronic security industry and to expanding GE Security, unrivalled expertise in Access Control current technologies, products and services that create revenue growth opportunities for its customers. As part of the GE family, GE Security shares the spirit of innovation that has distinguished GE for well over 100 years. GE Security's commitment to the ongoing success of its partners and affiliates means that we maintain a sharp focus on product and service innovation, world-class manufacturing practices and operational excellence. GE Security is a worldwide organisation with sales and technical support operations in 27 countries, and manufacturing and logistics operations in Europe, the U.S. and China. GE Security has expertise in all areas of electronic security, including: Intrusion and Fire Protection Electronic Access and Facility Management Key Management and Remote Access Systems and Services Fibre Optic Transmission and Reception Equipment CCTV, Digital Video and Surveillance Equipment Video Multiplexing and Digital Storage When you're looking for the finest in Access Control security products with leading-edge technology and the backing of a world leader, you need look no further than this catalogue.

2

3 READERS

4

5 Readers Page : 5 Stand-Alone Keypad for One-Door Control. Controller Built-In ACI5005 ACI5005 Stand-Alone Keypad The ACI5005 is a stand-alone keypad designed to be very simple to install and use. The keypad has three LEDs and a built-in buzzer that will give clear and easy to understand information, during programming and when the system is in use. The unit has a built-in memory for more than 1000 codes and the last 500 events. If print-outs of the log and timed functions are required the unit can be expanded by using the AC-S Manager Time & Log kit. The ACI5005 contains all of the electronics to control one door built in to the unit. In an application where someone may try to tamper with the unit, a "Slave reader" can be mounted on the outside of the door and the ACI5005 on the inside, in this configuration all of the door's control electronics will be located on the secure side of the door. Supply voltage Current consumption 12 VDC 60 ma 24 VDC 40 ma 12 to 24 VDC Outputs Lock relay (free switching relay C/NC/NO) Inputs Request to exit device Operating temperature -20 C to +50 C Programming Via keypad Via handheld programmer ACI5005 ACA000 ACA001 ACP111 Stand-Alone Keypad for One-Door Control. Controller Built-In Rain Protection Hood Request to Exit Button Surface Mounted Hand-Held Programmer - Also Acts As Printer Interface.

6 Readers Page : 6 Aluminum Keypad 'GE Security Design' ACI505 ACI Aluminum Keypad ACI505 keypad to be mounted beside the door to be controlled. Anyone requesting access must enter a personal identification number (PIN) at the keypad. The keypad is connected to a GE Security controller which contains the electronics to release the door. Supply voltage Current consumption Cable Indoor Outdoor (heater active) Keypad - Controller Keypad - ACI102 Interface - Interface - Controller - Cable other equipment Request to exit button - Controller Electric lock - Controller Door contact - Controller 12 VDC (from the controller) 45 ma 85 ma 4 wires, twisted pair, shielded 2 wires 4 wires 2 wires Operating temperature -25 C to +70 C Programming Dimensions (W x H x D) Weight Communication Via hand-held terminal Via PC-software Via modem 67 x 87 x 23 mm 350 g Current loop 20 ma (with controller) For access control where code only is requested Robust design Tamper proof Keypad to controller configuration For indoor or outdoor applications ACI505 ACA000 ACA001 ACA102 Aluminum Keypad 'GE Security Design' Rain Protection Hood Request to Exit Button Surface Mounted Wiegand interface - other readers

7 Readers Page : 7 Stand-Alone Card Reader for One-Door Control. Controller Built-In ACI6007 ACI6007 Identification Devices Stand-Alone Magstripe Reader The reader can be mounted beside the door to be controlled. Anyone requesting access must swipe a magnetically encoded card through the slot on the reader. The reader is equipped with a keypad and contains the electronics that release the door. The ACI6007 is a stand-alone magstripe reader with keypad designed to be very simple to install and use. The ACI6007 has three LEDs and a built-in buzzer that will give clear and easy to understand information, during programming and when the system is in use. The unit has a built-in memory for more than 2300 cards and the last 500 events. If print-outs of the log and timed functions are required the unit can be expanded by using the AC-S Manager Time & Log kit. The ACI6007 contains all of the electronics to control one door built in to the unit. In an application where someone may try to tamper with the unit, a "Slave reader" can be mounted on the outside of the door and the ACI6007 on the inside, in this configuration all of the door control electronics will be located on the secure side of the door. Supply voltage Current consumption Indoor Outdoor (heater active) Cabeling Reader - Lock Reader - Door contact Reader - Power supply Reader - Request to exit Optional cable Reader - External alarm system Reader - Aritech controller 12 / 24 VDC (from the controller) 60 / 40 ma 150 / 95 ma Two wires unshielded Two wires unshielded Two wires unshielded Two wires unshielded Six wires unshielded 4 wires Operating temperature -25 C to +50 C Programming Via keypad and card reader Via hand-held programmer Via PC-software Dimensions (W x H x D) 96 x 96 x 38 mm Weight 430 g Inputs Outputs Request to exit device Door monitoring Alarm armed - Input from external alarm system Trouble when attempting to arm -Input from external alarm system Lock relay (free switching relay C/NC/NO) Magstripe reader with keypad and built-in electronics Robust design Tamper protected Programmable by : - Keypad - Hand-held programmer - Personal computer For indoor or outdoor applications Expandable ACI6007 ACA000 ACA001 ACT600 ACT600S Stand-Alone Card Reader for One-Door Control. Controller Built-In Rain Protection Hood Request to Exit Button Surface Mounted Magstripe Card With Aritech Logo - Blue Magstripe Card - No Logo

8 Readers Page : 8 Magstripe Card Reader Without Keypad. Track 2 is Used ACI606S18 ACI606S18 Magstripe Reader ACI606S18 reader to be mounted beside the door to be controlled. Anyone requesting access must swipe a magnetically encoded card through the slot on the reader. The reader is connected to a GE Security controller which contains the electronics to release the door. Supply voltage Current consumption Indoor Outdoor (heater active) Cabeling Reader - Controller Request to exit button - Controller Electric lock - Controller Door contact - Controller 12 VDC (from the controller) 18 ma 86 ma 4 wires, twisted pair, shielded 2 wires 4 wires 2 wires Operating temperature -25 C to +70 C Programming Via hand-held terminal Via PC-software Via modem (Windows) Dimensions (H x W x D) 96 x 45 x 38 mm Weight 250 g Communication Current loop 20 ma (with controller) ACI606S18 ACI607S18 ACT600 ACT600S ACA000 ACA001 Magstripe Card Reader Without Keypad. Track 2 is Used Magstripe Card Reader With Built-In Keypad. Track 2 is Used Magstripe Card With Aritech Logo - Blue Magstripe Card - No Logo Rain Protection Hood Request to Exit Button Surface Mounted For different kinds of magstripe cards Robust design Tamper proof Reader to controller configuration For indoor or outdoor applications With or without keypad

9 Readers Page : 9 Magstripe Card Reader With Built-In Keypad. Track 2 is Used ACI607S18 ACI607S18 Magstripe Reader, With Keypad ACI607S18 reader with keypad to be mounted beside the door to be controlled. Anyone requesting access must swipe a magnetically encoded card through the slot on the reader. The reader is connected to a GE Security controller which contains the electronics to release the door. Supply voltage Current consumption Indoor Outdoor (heater active) Cabeling Reader - Controller Request to exit button - Controller Electric lock - Controller Door contact - Controller 12 / 24 VDC (from the controller) 45 ma 86 ma 4 wires, twisted pair, shielded 2 wires 4 wires 2 wires Operating temperature -25 C to +70 C Programming Via hand-held terminal Via PC-software Via modem Dimensions (W x H x D) 96 x 96 x 38 mm Weight 400 g Communication Current loop 20 ma (with controller) ACI607S18 ACI606S18 ACT600 ACT600S ACA000 ACA001 Magstripe Card Reader With Built-In Keypad. Track 2 is Used Magstripe Card Reader Without Keypad. Track 2 is Used Magstripe Card With Aritech Logo - Blue Magstripe Card - No Logo Rain Protection Hood Request to Exit Button Surface Mounted For different kinds of magstripe cards Robust design Tamper proof Reader to controller configuration For indoor or outdoor applications With or without keypad

10 Readers Page : 10 GE Security Proximity Reader, 0-10 cm Reading Range ACI711 ACI711 Proxreader, Potted ACI711 reader to be mounted beside the door to be controlled. Anyone requesting access must present a Proxcard to the reader. The reader is connected to a GE Security controller which contains the electronics to release the door. For in/outdoor usage. Supply voltage Maximum current consumption Dimensions (H x W x D) Operating temperature Transmit frequency Maximum cable length Wiegand Current loop VDC 100 ma 78 x 78 x 25 mm -25 C to +70 C 125 khz 150 m 800 m ACI711 ACA711 ACA711U ACT707 ACT708 ACT731 ACA000 ACA001 GE Security Proximity Reader, 0-10 cm Reading Range Surface Mounting Kit for ACI711 Flush Mounting Kit for ACI711 GE Security Proximity Card ISO Thickness - No Logo GE Security Proximity Card ISO Thickness With Magstripe - No Logo GE Security Proximity Keyfob, to Fit on a Keyring Rain Protection Hood Request to Exit Button Surface Mounted Robust molded plastic housing Indoor or outdoor mounting Current loop or Wiegand communication to controller Standard electrical box size

11 Readers Page : 11 GE Security Design Proximity Reader, 0-10 cm Reading Range ACI712 ACI712 Proxreader ACI712 reader to be mounted beside the door to be controlled. Anyone requesting access must present a Proxcard to the reader. The reader is connected to a GE Security controller which contains the electronics to release the door. For indoor usage. Supply voltage Maximum current consumption Dimensions (H x W x D) Operating temperature Transmit frequency Maximum cable length Wiegand Current loop VDC 100 ma 78 x 78 x 25 mm -25 C to +70 C 125 khz 150 m 800 m ACI712 ACT707 ACT708 ACT731 ACA000 ACA001 GE Security Design Proximity Reader, 0-10 cm Reading Range GE Security Proximity Card ISO Thickness - No Logo GE Security Proximity Card ISO Thickness With Magstripe - No Logo GE Security Proximity Keyfob, to Fit on a Keyring Rain Protection Hood Request to Exit Button Surface Mounted Molded plastic housing Indoor or outdoor mounting Tamper monitoring Current loop or Wiegand communication to controller Standard electrical box size

12 Readers Page : 12 HID ProxPro Plus 0-20 cm reading range ACI730 Proximity Card Reader ACI730 reader combines the popular features of the ACI730 reader with thin, inconspicuous housing, longer read range and new mounting configurations. ACI730 is designed for glass, mullion or surface mounting applications. Typical maximum read range ACT725, ACT736 ACT786 ACT745 ACT790 up to 25.5 cm up to 22.5 cm up to 15 cm Dimensions 190 x 190 x 23 mm Material Polycarbonate UL 94 Power supply VDC Current requirements Average Peak NA 100 ma (12 VDC) 120 ma (24 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95% relative humidity non-condensing Weight 426 g Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or Clk/data ACI730 ACT724 ACT ACT ACT ACT ACT ACT ACA m HID ProxPro Plus 0-20 cm reading range PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Affords high reliability, consistent read range characteristics and low power consumption in a single, easy-to-install package Features multicolour LED, internal or host control of the LED and/or beeper and a beeper off switch for silent operation Provides Wiegand protocol interface compatibility with all standard access control systems Offers an optional, fully integrated personal identification number keypad for heightened security. Can be mounted to glass (using the optional glass mounting kit) Requires a Wiegand interface (ACA102)

13 Readers Page : 13 HID EntryProx Stand-Alone Reader, 0-20 cm Reading Range ACI740 Stand-Alone Reader 125 khz Providing single-door proximity access control, EntryProx is ideal for small installations or remote locations when used in conjunction with an on-line system. This rugged, attractive unit can easily be modified to become an on-line reader by switching to a Wiegand output mode, allowing it to connect to any OEM controller. EntryProx is compatible with all HID proximity cards and keytags. Typical maximum read range ACT725, ACT736 ProxCard II card up to 7.6 cm ACT786 ISOProx II card ACT745 ProxKey II keyfob up to 6.35 cm up to 3.8 cm Dimensions (H x W x D) x 698 x 41 mm Material Polycarbonate UL 94 Power supply VDC, reverse voltage protected Current requirements VDC Operating temperature -35 C to +66 C Operating humidity 5% to 95% relative humidity non-condensing Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock and data interface 152 m Relay outputs Monitor inputs Sounder LEDs Operation Card programming Facility code processing options (26-bit only) Requires a Wiegand interface (ACA 102) If connected to controller Strike relay - Form C, switches up to 30 VDC Aux relay - Form C, switches up to 30 VDC Door position - N.O. dry contact Request to exit - N.O. dry contact 4000 Hz, defeatable Bi-colour (red/green), amber, infrared (use with optional palmtop printer) Strike time: 1-99 seconds (adjustable) Strike mode: Access timer or toggle/latch Door ajar time: Seconds (Adjustable) 26-bit format - batch enrollment OEM proprietary format - present card to enroll Check facility code and card ID Check facility code only (accept any ID#) Invalid PIN lockout - prevents unauthorized persons from gaining PIN code entry by trial and error 12-Position keypad - for PIN entry or programming; the PIN keypad is functional in Wiegand mode Single read mode - prevents anti-passback errors when the EntryProx is in Wiegand mode Block delete - allows a sequential range of cards/keytags to be deleted from the EntryProx by user location Detachable antenna module - can be mounted up to 10 feet away from the control unit, indoors or outdoors ACI740 ACT724 ACT ACT ACT ACT ACT ACT ACA102 HID EntryProx Stand-Alone Reader, 0-20 cm Reading Range PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers

14 Readers Page : 14 HID ProxPro Reader, 0-20 cm Reading Range ACI khz Versatile Proximity Card Reader The ProxPro proximity card reader s weatherproof design and architecturally attractive enclosure allows easy mounting indoors or out. The ProxPro Reader is ideal for applications requiring a larger read range. Typical maximum read range ACT725, ACT736 ACT786 ACT745 ACT790 up to 20 cm up to 17.5 cm up to 7.5 cm Dimensions (W X H X D) 127 x 127 x 25.4 mm Material Polycarbonate UL 94 Power supply VDC Current requirements Average Peak NA 100 ma (12 VDC) 120 ma (24 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95 % relative humidity non-condensing Weight 336 g Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data ACI755 ACT724 ACT ACT ACT ACT ACT ACT ACA m HID ProxPro Reader, 0-20 cm Reading Range PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Affords high reliability, consistent read range characteristics and low power consumption in a single, easy-to-install package Features multicolour LED, internal or host control of the LED, and/or beeper and a beeper off switch for silent operation Provides Wiegand protocol interface compatibility with all standard access control systems Requires a Wiegand interface (ACA 102)

15 Readers Page : 15 HID ProxPro With Keypad, 0-20 cm Reading Range ACI khz Versatile Proximity Card Reader, With Keypad The ACI757 proximity card reader s weatherproof design and architecturally attractive enclosure allows easy mounting indoors or out. The ACI757 Reader is ideal for applications requiring a larger read range. The ACI757 has a built in keypad. Typical maximum read range ACT725, ACT736 ProxCard II card up to 20 cm ACT786 ISOProx II card ACT745 ProxKey II keyfob up to 17.5 cm up to 7.5 cm Dimensions (W X H X D) 127 x 127 x 25.4 mm Material Polycarbonate UL 94 Power supply VDC Current requirements Average Peak 100 ma (12 VDC) 120 ma (24 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95 % relative humidity non-condensing Weight 336 g Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data interface ACI757 ACT724 ACT ACT ACT ACT ACT ACT ACA m HID ProxPro With Keypad, 0-20 cm Reading Range PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Affords high reliability, consistent read range characteristics and low power consumption in a single, easy-to-install package Features multicolour LED, internal or host control of the LED and/or beeper and a beeper off switch for silent operation Provides Wiegand protocol interface compatibility with all standard access control systems Offers an optional, fully integrated personal identification number keypad for heightened security. Can be mounted to glass (using the optional glass mounting kit) Requires a Wiegand interface (ACA102)

16 Readers Page : 16 HID ProxPoint Reader, +/- 0-5 cm Reading Range ACI760 Value Priced Proximity Card Reader ACI760 reader combines multiple configuration options with an attractive, inconspicuous design and economical price. Its secure potted electronics are ideal for both indoor and outdoor applications. Typical maximum read range ACT725, ACT736 ProxCard II card up to 7.6 cm ACT786 ISOProx II card ACT745 ProxKey II keyfob up to 6.35 cm up to 3.8 cm Dimensions (H x W x D) 79.6 x 43.7 x 16.8 mm Material Polycarbonate UL 94 Power supply 5-16 VDC Current requirements Average Peak 30 ma 75 ma Operating temperature -30 C to +65 C Operating humidity 0-95 % relative humidity non-condensing Weight 75 g Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data interface ACI760 ACT724 ACT ACT ACT ACT ACT ACT ACA m HID ProxPoint Reader, +/- 0-5 cm Reading Range PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Features a beeper and multicolour LED which can be hosted or locally controlled Enables various beeper and LED configurations, depending on individual site requirements Can read HID cards with formats up to 85 bits Designed for mounting directly onto metal with no change in read range performance Compatible with all standard access control systems Aesthetic design available in two cover designs and in four colours to match any decor Includes multilingual installation manual Requires a Wiegand interface (ACA102)

17 Readers Page : 17 HID MiniProx Reader, 0-10 cm Reading Range - ACI765 Modified ACI766 Proximity Card Reader The MiniProx proximity card reader s potted electronics and slim, attractive design are ideal for indoor or outdoor mounting. Typical maximum read range ACT725, ACT736 ProxCard II card up to 14 cm ACT786 ISOProx II card ACT745 ProxKey II keyfob up to 12.5 cm up to 5 cm Dimensions 152 x 43 x 25.4 mm Material Polycarbonate UL 94 Power supply 5-16 VDC Current requirements Average Peak 30 ma (5 VDC); 20 ma (12 VDC) 110 ma (5 VDC); 110 ma (12 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95% relative humidity non-condensing Weight 108 g Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data interface ACI766 ACT724 ACT ACT ACT ACT ACT ACT ACA m HID MiniProx Reader, 0-10 cm Reading Range - ACI765 Modified PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Accepts 5 to16 volts, meeting most voltage requirements. Allows easy upgrade from magstripe to a proximity reader; no rewiring or pulling of new cable required Offers high reliability, consistent read-range and low power consumption in an easy-to-install package Mounts directly onto metal with no change in read range performance. Provides multicolour LED, compatibility with all standard access control systems and internal or host control of LED and beeper Requires a Wiegand interface (ACA102)

18 Readers Page : 18 HID MaxiProx Reader, 0-60 cm Reading Range (Newly Improved) ACI775 Proximity Card Reader The ACI775 Reader is ideal for installations incorporating parking control and long read range applications. The MaxiProx reader packages all the electronics in one rugged, attractive and easy-to install housing. The long read range of the MaxiProx reader provides a significant user advantage by minimizing or eliminating the effort required to present an access-control card. This makes the MaxiProx reader ideal for installations incorporating parking control or where special consideration is needed to facilitate access for the physically challenged. The MaxiProx reader packages all of the electronics in one rugged, attractive and easy-to-install housing. The broad selection of HID proximity readers allows the use of one card for all your access control requirements. Typical maximum read range ACT725, ACT736 ACT786 ACT745 ACT790 up to 73 cm up to 50 cm up to 43 cm up to 2.4 m Dimensions (W x H x D) 300 x 300 x 25.4 mm Material Polycarbonate UL 94 Power supply Configurable 12 or 24 VDC Current requirements Average Peak 200 ma (12 VDC) 1.2 A (24 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95% relative humidity non-condensing Weight 1.4 kg Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data 152 m Long read range distance (up to 8 with ACT790) Autotune allows read range to be maintained within four inches of metal Parking hold feature allows connection to a loop detector to ensure accurate detection of vehicles in parking lanes Compatible with all HID cards and tags with formats up to 85 bits Multicolour LED with internal or host control of the LED and beeper Two ACI775 units can operate one meter apart for HI-LO (truck and car) installations Reader supervision signal for CASI-RUSCO panels Requires a Wiegand interface (ACA102) ACI775 ACT724 ACT ACT ACT ACT ACT ACT ACT ACA102 HID MaxiProx Reader, 0-60 cm Reading Range (Newly Improved) PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin ProxPass Long Range Transponder (With Batteries) - High Reading Range Wiegand interface - other readers

19 Readers Page : 19 HID Thinline II Reader, 0-14 cm Reading Range ACI795 Low Profile Proximity Card Reader Providing performance and reliability, HID s attractive, unobtrusive ThinLine II proximity card reader is housed in a two-piece, weatherproof secure potted enclosure. Typical maximum read range ACT725, ACT736 ProxCard II card up to 14 cm ACT786 ISOProx II card ACT745 ProxKey II keyfob up to 12.7 cm up to 5.1 cm Dimensions (H x W x D) 119 x 76 x 17 mm Material Polycarbonate UL 94 Power supply 5-16 VDC Current requirements Average Peak 30 ma (5 VDC); 20 ma (12 VDC) 110 ma (5 VDC); 115 ma (12 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95% relative humidity non-condensing Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data interface ACI795 ACI795W ACT724 ACT ACT ACT ACT ACT ACT ACA m HID Thinline II Reader, 0-14 cm Reading Range HID Thinline II Reader, 0-14 cm Reading Range, White PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Easily installed and maintained with the use of replaceable covers Provides high reliability, consistent read range and low power consumption Features include multicolour LED and internal control or host control of the LED and beeper Mounts directly on metal with minimal impact on the read range performance Aesthetic design available in two cover designs and four colours to match any decor Includes multilingual installation manual Requires a Wiegand interface (ACA102)

20 Readers Page : 20 HID Thinline II Reader, 0-14 cm Reading Range, White ACI795W Low Profile Proximity Card Reader Providing performance and reliability, HID s attractive, unobtrusive ThinLine II proximity card reader is housed in a two-piece, weatherproof secure potted enclosure. Typical maximum read range ACT725, ACT736 ProxCard II card up to 14 cm ACT786 ISOProx II card ACT745 ProxKey II keyfob up to 12.7 cm up to 5.1 cm Dimensions (H x W x D) 119 x 76 x 17 mm Material Polycarbonate UL 94 Power supply 5-16 VDC Current requirements Average Peak 30 ma (5 VDC); 20 ma (12 VDC) 110 ma (5 VDC); 115 ma (12 VDC) Operating temperature -30 C to +65 C Operating humidity 0-95% relative humidity non-condensing Transmit frequency 125 khz Excite frequency 125 khz Cable distance Wiegand or clock/data interface ACI795W ACI795 ACT724 ACT ACT ACT ACT ACT ACT ACA m HID Thinline II Reader, 0-14 cm Reading Range, White HID Thinline II Reader, 0-14 cm Reading Range PVC Label for ProxCard II - for ACT725 HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Wiegand interface - other readers Easily installed and maintained with the use of replaceable covers Provides high reliability, consistent read range and low power consumption Features include multicolour LED and internal control or host control of the LED and beeper Mounts directly on metal with minimal impact on the read range performance Aesthetic design available in two cover designs and four colours to match any decor Includes multilingual installation manual Requires a Wiegand interface (ACA102)

21 Readers Page : 21 Barcode Card Reader Without Keypad ACI806 ACI800 Series Identification Devices Barcode Readers ACI806 reader to be mounted beside the door to be controlled. Anyone requesting access must swipe a barcode card through the slot on the reader. The reader is connected to a GE Security controller which contains the electronics to release the door. Supply voltage 12 VDC (from the controller) Current consumption Cable Indoor Outdoor (heater active) Reader - Controller Request to exit button - Controller Electric lock - Controller Door contact - Controller 55 ma 115 ma 4 wires, twisted pair, shielded 2 wires 4 wires 2 wires Operating temperature -25 C to +70 C Programming Not via keypad Via hand-held terminal Via PC-software Via modem Dimensions (H x W x D) 86 x 68 x 31 mm Weight 220 g Communication Current loop 20 ma (with controller) High security reader technology Robust design Tamper proof Reader to controller configuration For indoor or outdoor applications With or without keypad ACI806 ACI807 ACT800 ACT800S Barcode Card Reader Without Keypad Barcode Card Reader With Built-In Keypad Barcode Card With Aritech Logo - Red Barcode Card - No Logo. Minimum Order Quantity 200

22 Readers Page : 22 Barcode Card Reader With Built-In Keypad ACI807 ACI800 Series Identification Devices Barcode Readers ACI807 reader with keypad to be mounted beside the door to be controlled. Anyone requesting access must swipe a barcode card through the slot on the reader. The reader is connected to a GE Security controller which contains the electronics to release the door. Supply voltage 12 VDC (from the controller) Current consumption Cable Indoor Outdoor (heater active) Reader - Controller Request to exit button - Controller Electric lock - Controller Door contact - Controller 55 ma 115 ma 4 wires, twisted pair, shielded 2 wires 4 wires 2 wires Operating temperature -25 C to +70 C Programming Via keypad Via hand-held terminal connected to the controller Via application software in personal computer (Windows) Via modem and software in personal computer (Windows) Dimensions (H x W x D) 86 x 112 x 31 mm Weight 445 g Communication Current loop 20 ma (with controller) High security reader technology Robust design Tamper proof Reader to controller configuration For indoor or outdoor applications With or without keypad ACI807 ACI806 ACT800 ACT800S Barcode Card Reader With Built-In Keypad Barcode Card Reader Without Keypad Barcode Card With Aritech Logo - Red Barcode Card - No Logo. Minimum Order Quantity 200

23 CARDS

24

25 Cards Page : 25 Magstripe Card With Aritech Logo - Blue ACT600 ACT600 Magstripe Card Magstripe card with blue Aritech logo, preprogrammed. ACT600 ACT600S ACI606S18 ACI607S18 ATS1156 Magstripe Card With Aritech Logo - Blue Magstripe Card - No Logo Magstripe Card Reader Without Keypad. Track 2 is Used Magstripe Card Reader With Built-In Keypad. Track 2 is Used ATS Aluminum Card Reader With Keypad, Magstripe Magstripe Card - No Logo ACT600S ACT600 Magstripe Card Magstripe card without logo, preprogrammed. ACT600S ACT600 ACI606S18 ACI607S18 ATS1156 Magstripe Card - No Logo Magstripe Card With Aritech Logo - Blue Magstripe Card Reader Without Keypad. Track 2 is Used Magstripe Card Reader With Built-In Keypad. Track 2 is Used ATS Aluminum Card Reader With Keypad, Magstripe

26 Cards Page : 26 GE Security Proximity Card ISO Thickness - No Logo ACT707 ACT707 Proximity Card Prox card white, preprogrammed. For the ACI711 and ACI712 readers. ACT707 GE Security Proximity Card ISO Thickness - No Logo GE Security Proximity Card ISO Thickness With Magstripe - No Logo ACT708 ACT707 Proximity Card With Magstripe Prox card white, preprogrammed, with unprogrammed Magstripe. For the ACI711 and ACI712 readers. ACT708 GE Security Proximity Card ISO Thickness With Magstripe - No Logo

27 Cards Page : 27 PVC Label for ProxCard II - for ACT725 ACT724 Adhesive Label The ACT724 is used with the ACT725 and is compatible with most direct image printers. ACT724 PVC Label for ProxCard II - for ACT725

28 Cards Page : 28 HID ProxCard II ACT725 Proximity Access Card The RF-programmable ACT725 proximity access card is the industry choice for a cost-effective solution to proximity access control. Typical read range MiniProx reader ThinLine II reader ProxPro reader MaxiProx reader cm cm cm cm Features Proven, reliable technology: The read range of the cards is extremely consistant and not affected by body shielding or variable environmental conditions, even when close to keys and coins. Dimensions (W x H x D) 54 x 86 x 2 mm Small and convenient The cards can be carried with your credit cards in your wallet or purse. Card construction All cards are slot punched, offer custom graphics, and are compatible with most adhesive photo pouches. Cross-reference A cross-reference list correlating the external number and the programmed ID number is provided for easy system administration. Operating temperature -45 C to +70 C; relative humidity 5-95% non-condensing Security The cards and keyfob offer over 137 billion unique codes. Long life The cards and keyfob offer a passive, no-battery design allowing an infinite number of reads. Weight 6,8 g Durability The cards and keyfob are strong and flexible for resistance to cracking and breaking. Description Low frequency 125 khz, sequential matching card number internal and external. Offers universal compatibility with all HID proximity readers Provides durable packaging and consistent read range Provides an external number for easy identification and control HID standard 32-bit configuration A PVC overlay allows for on-site photo ID using most direct image printers Available in sitecode 10 & 20 ACT ACT HID ProxCard II - Sitecode 10 HID ProxCard II - sitecode 20

29 Cards Page : 29 GE Security Proximity Keyfob, to Fit on a Keyring ACT731 ACT707 Proximity Keyfob Prox keyfob black or grey, preprogrammed. For the ACI711 and ACI712 readers. ACT731 GE Security Proximity Keyfob, to Fit on a Keyring

30 Cards Page : 30 HID DuoProx II card - ISO thickness, suitable for dye sublimation prin ACT Multiple Technology Proximity Card The RF-programmable ACT736 multiple technology proximity card offers proximity, magnetic stripe and photo identification technologies on a single access control card. Typical read range MiniProx reader ThinLine II reader ProxPro reader MaxiProx reader 5-10 cm 5-10 cm cm cm Features Proven, reliable technology: The read range of the cards is extremely consistant and not affected by body shielding or variable environmental conditions, even when close to keys and coins. Dimensions (W x H x D) 54 x 87 x 0.8 mm Small and convenient The cards can be carried with your credit cards in your wallet or purse. Card construction All cards are slot punched, offer custom graphics, and are compatible with most adhesive photo pouches. Cross-reference A cross-reference list correlating the external number and the programmed ID number is provided for easy system administration. Operating temperature -45 C to +70 C; relative humidity 5-95% non-condensing Security The cards and keyfob offer over 137 billion unique codes Long life The cards and keyfob offer a passive, no-battery design allowing an infinite number of reads. Weight 6.8 g Durability The cards and keyfob are strong and flexible for resistance to cracking and breaking. Description Low frequency 125 khz, sequential matching card number internal and external. Offers universal compatibility with all HID proximity readers Provides an external number for easy identification and control HID standard 32-bit configuration Meets ISO standards for thickness; Use with all direct image or thermal transfer printers Accepts either a horizontal or vertical slot punch Sitecode 20 ACT HID DuoProx II card - ISO thickness, suitable for dye sublimation prin

31 Cards Page : 31 HID ProxKey II Proximity Keyfob ACT745 Proximity Keyfob The RF-programmable ACT745 proximity keyfob incorporates proximity technology into a convenient device approximately the size of an automotive key. Typical read range MiniProx reader ThinLine II reader ProxPro reader MaxiProx reader Features Dimensions (H x W x D) Small and convenient Card construction upto 5 cm cm upto 7.6 cm upto 30.4 cm 48 x 23 x 9 mm The keyfob can be carried with your keys in your pocket or handbag. Cross-reference A cross-reference list correlating the external number and the programmed ID number is provided for easy administration. Operating temperature -45 C to +70 C; relative humidity 5-95% non-condensing Security The cards and keyfob offer over 137 billion unique codes. Long life The cards and keyfob offer a passive, no-battery design allowing an infinite number of reads. Weight 7.3 g Durability The cards and keyfob are strong and flexible for resistance to cracking and breaking. ACT ACT HID ProxKey II Proximity keyfob - sitecode 10 HID ProxKey II Proximity keyfob - sitecode 20 Offers universal compatibility with all HID proximity readers Can be placed on a key ring for convenient entry Provides an external number for easy identification and control HID standard 32-bit configuration Available in sitecode 10 & 20

32 Cards Page : 32 HID ISOProx II card - ISO thickness, suitable for dye sublimation prin ACT Proximity Access Card The RF-programmable ACT786 proximity access card offers proximity technology and photo identification on a single access control card. Typical read range MiniProx reader ThinLine II reader ProxPro reader MaxiProx reader 5-10 cm 5-10 cm cm cm Features Proven, reliable technology: The read range of the cards is extremely consistant and not affected by body shielding or variable environmental conditions, even when close to keys and coins. Dimensions 54 x 87 x 8 mm Small and convenient The cards can be carried with your credit cards in your wallet or purse. Card construction All cards are slot punched, offer custom graphics, and are compatible with most adhesive photo pouches Cross-reference A cross-reference list correlating the external number and the programmed ID number is provided for easy administration Operating temperature -45 C to +70 C; relative humidity 5-95% (non-condensing) Security The cards and keyfob offer over 137 billion unique codes. Long life The cards and keyfob offer a passive, no-battery design allowing an infinite number of reads. Weight 6.8 g Durability The cards and keyfob are strong and flexible for resistance to cracking and breaking Description Low frequency 125 khz, sequential matching card number internal and external ACT HID ISOProx II card - ISO thickness, suitable for dye sublimation prin Offers universal compatibility with all HID proximity readers. Provides durable packaging and consistent read range Provides an external number for easy identification and control HID standard 32-bit configuration Meets ISO standards for thickness; use with all direct image or thermal transfer printers Accepts either a horizontal or vertical slot punch Sitecode 20

33 Cards Page : 33 ProxPass Long Range Transponder (With Batteries) - High Reading Range ACT Long Range Proximity Transponder The ACT790 is an active tag specifically designed for vehicle access control. Providing convenient access control for parking and fleet management applications, ACT790 is an ideal augmentation to an existing or new HID proximity installation. It can be encoded with most HID formats and numbering systems used by HID proximity cards, including the corporate 1000 format. Typical read range MiniProx reader - ThinLine II reader - ProxPro reader - MaxiProx reader Features Dimensions Small and convenient Card construction cm 68 x 92 x 8 mm ProxPass on interior windscreen of vehicle Cross-reference A cross-reference list correlating the external number and the programmed ID number is provided for easy system administration Operating temperature -30 C to +85 C Security The cards and keyfob offer over 137 billion unique codes. Long life The ProxPass dual battery design and low current allows 2-5 years with typical usage. ACT ProxPass Long Range Transponder (With Batteries) - High Reading Range Provides a six to eight foot read range Velcro backing attaches easily to interior of vehicle windshield Attractive, durable sealed case Compatible with ACI775 reader Two to five year battery life, depending on usage Competitively priced as compared to VHF vehicle tags Sitecode 20

34 Cards Page : 34 Barcode Card With Aritech Logo - Red ACT800 ACT800 Barcode Card Barcode card with red Aritech logo, preprogrammed. ACT800 Barcode Card With Aritech Logo - Red Barcode Card - No Logo. Minimum Order Quantity 200 ACT800S ACT800S Barcode Card Barcode card without logo, preprogrammed. ACT800S Barcode Card - No Logo. Minimum Order Quantity 200

35 Cards Page : 35 Card Holder With Beltclip IDP67 Card Holders Card holder with beltclip. IDP67 IDS940M Card Holder With Beltclip Self-Retracting Reel to Attach Beltclip to - Length: approx. 1 m Self-Retracting Reel to Attach Beltclip to - Length: approx. 1 m IDS940M Card Holders Self-retracting reel to attach beltclip to. Length: approx 1 m. IDS940M IDP67 Self-Retracting Reel to Attach Beltclip to - Length: approx. 1 m Card Holder With Beltclip

36

37 CONTROLLERS

38

39 Controller Page : 39 Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) ACC1 ACC Series of Access Controllers The ACC Series are reliable, high quality controllers with excellent value for money. The controllers have outputs for: - Electric lock - Alarm arm/disarm - Trouble output - External buzzer (pre-warning) - Communication to readers, other controllers and a PC Supply voltage Power supply ACC 1PS12 ACC 1PS24 ACC 4PS12 ACC 4PS24 Current consumption ACC 1 ACC 4 12 or 24 VDC 2 A 1 A 4 A 3 A 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller: 4 wires, twisted pair, shielded Controller to Keycard: 4 wires, twisted pair, shielded Controller to PC (1 controller, max. 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Dimensions Weight ACC 1 ACC 4 ACC 1PS ACC 1 ACC 4PS ACC x 335 x 85 mm 500 x 400 x 90 mm 5000 g 3500 g 9500 g 6000 g Communication Current loop 20 ma (with controller) Memory size Cards and codes/logs ACC1 3780/1000 ACC4 6898/2000 On board serial ports ACC1 ACC4 Printer/modem or PC No/1 port 1 port/1 port Without power supply Tamper-proof housing Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups ACC1 ACC1PS12 ACC1PS24 ACC4 ACC4PS12 ACC4PS24 ACA101 ACA102 Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Relay Card for Expansion of In/Outputs Wiegand interface - other readers

40 Controller Page : 40 Mini Controller for a One Door Application ACC1000 Mini Controller for a One Door Application. The ACC1000 is designed to be quick and simple to install. This mini controller can work with any standard GE Secrity slave reader technology: magnetic, barcode, proximity, Wiegand and pin-code. Supply voltage 12 to 24 VDC (no power supply included) Current consumption VDC, 24 VDC (without slave reader) Outputs Lock relay (free switching relay C/NC/NO) Alarm relay (free switching relay C/NC/NO) programmable pulse/latch Inputs Request to exit device Current loop slave reader Operation temperature -20 C to +50 C Dimensions (H x W x D) 98 x 67 x 40 mm Programming Via handheld programmer Via slave reader with keypad ACC1000 Mini Controller for a One Door Application ACI505 Aluminum Keypad 'GE Security Design' ACI606S18 Magstripe Card Reader Without Keypad. Track 2 is Used ACI607S18 Magstripe Card Reader With Built-In Keypad. Track 2 is Used ACI711 GE Security Proximity Reader, 0-10 cm Reading Range ACI712 GE Security Design Proximity Reader, 0-10 cm Reading Range ACI806 Barcode Card Reader Without Keypad ACI807 Barcode Card Reader With Built-In Keypad ACA000 Rain Protection Hood ACA001 Request to Exit Button Surface Mounted Mini controller for one door Universal reading technology: magstripe, barcode, proximity, code Indoor or outdoor applications Memory for: 1,289 cards or codes, 500 last events, 100 schedules,1 year calendar

41 Controller Page : 41 Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) ACC1PS12 ACC Series of Access Controllers The ACC Series are reliable, high quality controllers with excellent value for money. The controllers have outputs for: - Electric lock - Alarm arm/disarm - Trouble output - External buzzer (pre-warning) - Communication to readers, other controllers and a PC Supply voltage Power supply ACC 1PS12 ACC 1PS24 ACC 4PS12 ACC 4PS24 Current consumption ACC 1 ACC 4 12 or 24 VDC 2 A 1 A 4 A 3 A 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller: 4 wires, twisted pair, shielded Controller to Keycard: 4 wires, twisted pair, shielded Controller to PC (1 controller, max. 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Dimensions Weight ACC 1 ACC 4 ACC 1PS ACC 1 ACC 4PS ACC x 335 x 85 mm 500 x 400 x 90 mm 5000 g 3500 g 9500 g 6000 g Communication Current loop 20 ma (with controller) Memory size Cards and codes/logs ACC1 3780/1000 ACC4 6898/2000 On board serial ports ACC1 ACC4 Printer/modem or PC No/1 port 1 port/1 port With 12 V power supply Tamper-proof housing Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups ACC1PS12 ACC1 ACC1PS24 ACC4 ACC4PS12 ACC4PS24 ACA101 ACA102 BS127N Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Relay Card for Expansion of In/Outputs Wiegand interface - other readers Sealed Lead Acid Battery - 12 V Ah

42 Controller Page : 42 Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) ACC1PS24 ACC Series of Access Controllers The ACC Series are reliable, high quality controllers with excellent value for money. The controllers have outputs for: - Electric lock - Alarm arm/disarm - Trouble output - External buzzer (pre-warning) - Communication to readers, other controllers and a PC Supply voltage Power supply ACC 1PS12 ACC 1PS24 ACC 4PS12 ACC 4PS24 Current consumption ACC 1 ACC 4 12 or 24 VDC 2 A 1 A 4 A 3 A 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller: 4 wires, twisted pair, shielded Controller to Keycard: 4 wires, twisted pair, shielded Controller to PC (1 controller, max. 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Dimensions Weight ACC 1 ACC 4 ACC 1PS ACC 1 ACC 4PS ACC x 335 x 85 mm 500 x 400 x 90 mm 5000 g 3500 g 9500 g 6000 g Communication Current loop 20 ma (with controller) Memory size Cards and codes/logs ACC1 3780/1000 ACC4 6898/2000 On board serial ports ACC1 ACC4 Printer/modem or PC No/1 port 1 port/1 port With 24 V powersupply Tamper-proof housing Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups ACC1PS24 ACC1 ACC1PS12 ACC4 ACC4PS12 ACC4PS24 ACA101 ACA102 BS127N Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Relay Card for Expansion of In/Outputs Wiegand interface - other readers Sealed Lead Acid Battery - 12 V Ah

43 Controller Page : 43 Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) ACC4 ACC Series of Access Controllers The ACC Series are reliable, high quality controllers with excellent value for money. The controllers have outputs for: - Electric lock - Alarm arm/disarm - Trouble output - External buzzer (pre-warning) - Communication to readers, other controllers and a PC Supply voltage Power supply ACC 1PS12 ACC 1PS24 ACC 4PS12 ACC 4PS24 Current consumption ACC 1 ACC 4 12 or 24 VDC 2 A 1 A 4 A 3 A 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller: 4 wires, twisted pair, shielded Controller to Keycard: 4 wires, twisted pair, shielded Controller to PC (1 controller, max. 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Dimensions Weight ACC 1 ACC 4 ACC 1PS ACC 1 ACC 4PS ACC x 335 x 85 mm 500 x 400 x 90 mm 5000 g 3500 g 9500 g 6000 g Communication Current loop 20 ma (with controller) Memory size Cards and codes/logs ACC1 3780/1000 ACC4 6898/2000 On board serial ports ACC1 ACC4 Printer/modem or PC No/1 port 1 port/1 port Without power supply Tamper-proof housing Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups ACC4 ACC4PS12 ACC4PS24 ACC1 ACC1PS12 ACC1PS24 ACA101 ACA102 Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Relay Card for Expansion of In/Outputs Wiegand interface - other readers

44 Controller Page : 44 Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) ACC4PS12 ACC Series of Access Controllers The ACC Series are reliable, high quality controllers with excellent value for money. The controllers have outputs for: - Electric lock - Alarm arm/disarm - Trouble output - External buzzer (pre-warning) - Communication to readers, other controllers and a PC Supply voltage Power supply ACC 1PS12 ACC 1PS24 ACC 4PS12 ACC 4PS24 Current consumption ACC 1 ACC 4 12 or 24 VDC 2 A 1 A 4 A 3 A 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller: 4 wires, twisted pair, shielded Controller to Keycard: 4 wires, twisted pair, shielded Controller to PC (1 controller, max. 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Dimensions Weight ACC 1 ACC 4 ACC 1PS ACC 1 ACC 4PS ACC x 335 x 85 mm 500 x 400 x 90 mm 5000 g 3500 g 9500 g 6000 g Communication Current loop 20 ma (with controller) Memory size Cards and codes/logs ACC1 3780/1000 ACC4 6898/2000 On board serial ports ACC1 ACC4 Printer/modem or PC No/1 port 1 port/1 port With 12 V power supply Tamper-proof housing Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups ACC4PS12 ACC4PS24 ACC1 ACC1PS12 ACC1PS24 ACC4 ACA101 ACA102 BS127N Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) Relay Card for Expansion of In/Outputs Wiegand interface - other readers Sealed Lead Acid Battery - 12 V Ah

45 Controller Page : 45 Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) ACC4PS24 ACC Series of Access Controllers The ACC Series are reliable, high quality controllers with excellent value for money. The controllers have outputs for: - Electric lock - Alarm arm/disarm - Trouble output - External buzzer (pre-warning) - Communication to readers, other controllers and a PC Supply voltage Power supply ACC 1PS12 ACC 1PS24 ACC 4PS12 ACC 4PS24 Current consumption ACC 1 ACC 4 12 or 24 VDC 2 A 1 A 4 A 3 A 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller: 4 wires, twisted pair, shielded Controller to Keycard: 4 wires, twisted pair, shielded Controller to PC (1 controller, max. 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Dimensions Weight ACC 1 ACC 4 ACC 1PS ACC 1 ACC 4PS ACC x 335 x 85 mm 500 x 400 x 90 mm 5000 g 3500 g 9500 g 6000 g Communication Current loop 20 ma (with controller) Memory size Cards and codes/logs ACC1 3780/1000 ACC4 6898/2000 On board serial ports ACC1 ACC4 Printer/modem or PC No/1 port 1 port/1 port With 24 V powersupply Tamper-proof housing Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups ACC4PS24 ACC1 ACC1PS12 ACC1PS24 ACC4 ACC4PS12 ACA101 ACA102 BS127N Controller 4 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing - No Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Controller 1 Door, Incl. Housing and 24 VDC - Power Supply Unit (PSU) Controller 4 Doors, Incl. Housing - No Power Supply Unit (PSU) Controller 4 Door, Incl. Housing and 12 VDC - Power Supply Unit (PSU) Relay Card for Expansion of In/Outputs Wiegand interface - other readers Sealed Lead Acid Battery - 12 V Ah

46

47 SOFTWARE / PROGRAMMING TOOLS

48

49 Programming Page : 49 Hand-Held Programmer - Also Acts As Printer Interface. ACP111 The ACP111 Hand-Held Programmer The ACP111 hand-held programmer can be connected to the GE Security controller via the plug-in connector. The programming of the access control system's features can be achieved using the built-in keyboard, i.e.: - Calendar - Time schedules - Cards and codes - Reader technology Supply voltage Current consumption Operating temperature Dimensions (H x W x D) Weight Communication 12 or 24 VDC (from the controller) VDC VDC +10 C to +50 C (indoor usage only) 147 x 91 x 29 mm 200 g Current loop 20 ma (with controller) ACP111 Hand-Held Programmer - Also Acts As Printer Interface. ACP112 Interface for Remote Programming of Controller For programming of stand-alone reader or controller Plug-in connection LCD display - clear information For temporary or permanent connection On-board printer output Easy programming Password required to enter programming mode Last event shown on display

50 Programming Page : 50 Interface for Remote Programming of Controller ACP112 Remote Programming Interface Interface for connection of handheld programmer ACP111 from remote location. Supply voltage Current consumption Operating temperature Dimensions (H x W x D) Weight Communication 12 or 24 VDC (from the controller) VDC VDC +10 C to +50 C (indoor usage only) 70 x 52 x 25 mm 125 g Current loop 20 ma (with controller) ACP112 ACP111 Interface for Remote Programming of Controller Hand-Held Programmer - Also Acts As Printer Interface. RJ-45 connection Current loop (20 ma)

51 Programming Page : 51 Keycard Interface ACP201 RS232 to Current Loop Converter The keycard converts the RS232 communication from the PC to a current loop protocol. This devise is needed if the distance from the PC to the first controller is bigger then 25 m. ACP201 Keycard Interface RS232 PC connection RS232 modem connection Current loop connection 1 Relay for "PC software running" 1 Relay to be programmed from software

52 Programming Page : 52 Demo Software ACPDEMO ACS Foundation The software is used to administer data such as: card holder information, access levels, time schedules and parameter settings. This information is transmitted to the controllers where it is stored. Most functions do not require communication with the PC (off-line). However, some functions, ie. anti-pass back, require the information from more than one controller to be collected via the PC (on-line). The software is designed to enable advanced users to 'link' information to and from the access control software, such as valid access and certain (programmable) events in the access control system. Hardware requirements Software requirements ACPDEMO Demo Software A Pentium-based computer or higher At least 32 Mb of RAM memory At least 10 Mb of free space on your hard disk A serial COM port for each serial controller and/or loop connection A parallel port for the protection key Network card (if connecting to Ethernet) Microsoft Win 98, Win NT4.0, Win2000, Win XP On-line help features For (MS) Windows operating system Open protocol Up to 100,000 cards Tested for Windows98, 2000, NT and XP

53 Programming Page : 53 PC SW for One Controller With New Manuals on CDROM ACP4W ACS Foundation The software is used to administer data such as: card holder information, access levels, time schedules and parameter settings. This information is transmitted to the controllers where it is stored. Most functions do not require communication with the PC (off-line). However, some functions, ie. anti-pass back, require the information from more than one controller to be collected via the PC (on-line). The software is designed to enable advanced users to 'link' information to and from the access control software, such as valid access and certain (programmable) events in the access control system. Hardware requirements Software requirements ACP4W ACP500W ACPMUS ACPIP UPACP A Pentium-based computer or higher At least 32 Mb of RAM memory At least 10 Mb of free space on your hard disk A serial COM port for each serial controller and/or loop connection A parallel port for the protection key Network card (if connecting to Ethernet) Microsoft Win 98, Win NT4.0, Win2000, Win XP PC SW for One Controller With New Manuals on CDROM PC SW for Networked Controllers, Without Keycard with New Manuals Multi User Software for NT Server With License for 3 Clients Client Extension to ACPMUS - One License Upgrade Package for ACP4W, ACP500W 1.6 to and MUS 1.0 to 1.1 On-line help features For (MS) Windows operating system Open protocol Up to 100,000 cards Tested for Windows98, 2000, NT and XP

54 Programming Page : 54 PC SW for Networked Controllers, Without Keycard with New Manuals ACP500W ACS Foundation The software is used to administer data such as: card holder information, access levels, time schedules and parameter settings. This information is transmitted to the controllers where it is stored. Most functions do not require communication with the PC (off-line). However, some functions, ie. anti-pass back, require the information from more than one controller to be collected via the PC (on-line). The software is designed to enable advanced users to 'link' information to and from the access control software, such as valid access and certain (programmable) events in the access control system. Hardware requirements Software requirements ACP500W ACP4W ACPMUS ACPIP UPACP A Pentium-based computer or higher At least 32 Mb of RAM memory At least 10 Mb of free space on your hard disk A serial COM port for each serial controller and/or loop connection A parallel port for the protection key Network card (if connecting to Ethernet) Microsoft Win 98, Win NT4.0, Win2000, Win XP PC SW for Networked Controllers, Without Keycard with New Manuals PC SW for One Controller With New Manuals on CDROM Multi User Software for NT Server With License for 3 Clients Client Extension to ACPMUS - One License Upgrade Package for ACP4W, ACP500W 1.6 to and MUS 1.0 to 1.1 On-line help features For (MS) Windows operating system Open protocol Up to 100,000 cards Tested for Windows98, 2000, NT and XP

55 Programming Page : 55 Multi User Software for NT Server With License for 3 Clients ACPMUS ACS Foundation The software is used to administer data such as: card holder information, access levels, time schedules and parameter settings. This information is transmitted to the controllers where it is stored. Most functions do not require communication with the PC (off-line). However, some functions, ie. anti-pass back, require the information from more than one controller to be collected via the PC (on-line). The software is designed to enable advanced users to 'link' information to and from the access control software, such as valid access and certain (programmable) events in the access control system. Hardware requirements Software requirements ACPMUS ACP4W ACP500W ACPIP UPACP A Pentium-based computer or higher At least 64 Mb of RAM memory At least 80 Mb of free space on your hard disk A serial COM port for each serial controller and/or loop connection A parallel port for the protection key Network card Microsoft Win 98, Win NT4.0, Win2000, Win XP Multi User Software for NT Server With License for 3 Clients PC SW for One Controller With New Manuals on CDROM PC SW for Networked Controllers, Without Keycard with New Manuals Client Extension to ACPMUS - One License Upgrade Package for ACP4W, ACP500W 1.6 to and MUS 1.0 to 1.1 On-line help features For (MS) Windows operating system Open protocol Up to 100,000 cards Tested for Windows98, 2000, NT and XP

56 Programming Page : 56 Client Extension to ACPMUS - One License ACPIP ACS Foundation The software is used to administer data such as: card holder information, access levels, time schedules and parameter settings. This information is transmitted to the controllers where it is stored. Most functions do not require communication with the PC (off-line). However, some functions, ie. anti-pass back, require the information from more than one controller to be collected via the PC (on-line). The software is designed to enable advanced users to 'link' information to and from the access control software, such as valid access and certain (programmable) events in the access control system. Hardware requirements Software requirements ACPIP ACP4W ACP500W ACPMUS UPACP A Pentium-based computer or higher At least 64 Mb of RAM memory At least 80 Mb of free space on your hard disk A serial COM port for each serial controller and/or loop connection A parallel port for the protection key Network card Microsoft Win 98, Win NT4.0, Win2000, Win XP Client Extension to ACPMUS - One License PC SW for One Controller With New Manuals on CDROM PC SW for Networked Controllers, Without Keycard with New Manuals Multi User Software for NT Server With License for 3 Clients Upgrade Package for ACP4W, ACP500W 1.6 to and MUS 1.0 to 1.1 On-line help features For (MS) Windows operating system Open protocol Up to 100,000 cards Tested for Windows98, 2000, NT and XP

57 Programming Page : 57 Upgrade Package for ACP4W, ACP500W 1.6 to and MUS 1.0 to 1.1 UPACP ACS Foundation The software is used to administer data such as: card holder information, access levels, time schedules and parameter settings. This information is transmitted to the controllers where it is stored. Most functions do not require communication with the PC (off-line). However, some functions, ie. anti-pass back, require the information from more than one controller to be collected via the PC (on-line). The software is designed to enable advanced users to 'link' information to and from the access control software, such as valid access and certain (programmable) events in the access control system. Hardware requirements Software requirements UPACP ACP4W ACP500W ACPMUS ACPIP A Pentium-based computer or higher At least 32 Mb of RAM memory At least 10 Mb of free space on your hard disk A serial COM port for each serial controller and/or loop connection A parallel port for the protection key Network card (if connecting to Ethernet) Microsoft Win 98, Win NT4.0, Win2000, Win XP Upgrade Package for ACP4W, ACP500W 1.6 to and MUS 1.0 to 1.1 PC SW for One Controller With New Manuals on CDROM PC SW for Networked Controllers, Without Keycard with New Manuals Multi User Software for NT Server With License for 3 Clients Client Extension to ACPMUS - One License On-line help features For (MS) Windows operating system Open protocol Up to 100,000 cards Tested for Windows98, 2000, NT and XP

58 Programming Page : 58 Access Control CDROM Containing Commercial Literature, Manuals, etc ACCINFO Access Control Marketing CDROM Access Control CDROM containing commercial literature, manuals, etc. ACCINFO Access Control CDROM Containing Commercial Literature, Manuals, etc

59 MAGNETIC LOCKS

60

61 Magnetic Locks Page : 61 Mini Magnetic Lock for 1800 N, 12/24 VDC Reed Monitored FE310 Single Magnets - Monitored Mini magnetic lock for 1800 N, 12/24 VDC reed monitored, anodized aluminum. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 1800 N 12/24 VDC 380/190 ma Anodized aluminum 166 x 39 x 21 mm Reed FE31Z FE310 FE31Z Mini Magnetic Lock for 1800 N, 12/24 VDC Reed Monitored Adjustable L Bracket for 1800 N Series Mini Magnetic lock for 1800 N, 12/24 VDC reed monitored, Anodized Aluminium FE312 Single Magnets - Monitored Mini magnetic lock for 1800 N, 12/24 VDC reed monitored, anodized aluminium. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Mortice 1800 N 12/24 VDC 380/190 ma Anodized aluminum 166 x 39 x 21 mm Reed FE312 FE31Z Mini Magnetic Lock for 1800 N, 12/24 VDC Reed Monitored Adjustable L Bracket for 1800 N Series

62 Magnetic Locks Page : 62 Medium Magnetic Lock for 3000 N, 12/24 VDC Not Monitored FE319 Single Magnets - Not Monitored Medium magnetic lock for 3000 N, 12/24 VDC not monitored. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Standard / surface 3000 N 12/24 VDC 500/250 ma Anodized aluminum 229 x 39 x 24 mm FE319 FE32A FE32L FE32Z Medium Magnetic Lock for 3000 N, 12/24 VDC Not Monitored Surface Armature Housing for 3000 N Series Adjustable L Bracket for 3000 N Series Adjustable Z Bracket for 3000 N Series Adjustable L bracket for 1800 N series FE31Z L-Bracket Adjustable L bracket for 1800 N series. FE31Z Adjustable L Bracket for 1800 N Series

63 Magnetic Locks Page : 63 Medium Magnetic Lock for 3000 N - 12/24 VDC - Not Monitored FE321 Single Magnets - Not Monitored Medium magnetic lock for 3000 N, 12/24 VDC not monitored, aluminum housing. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Brackets Standard / surface 3000 N 12/24 VDC 500/250 ma Anodized aluminum 268 x 48 x 25 mm FE32Z, FE32L, FE32A FE321 FE32Z FE32L FE32A Medium Magnetic Lock for 3000 N - 12/24 VDC - Not Monitored Adjustable Z Bracket for 3000 N Series Adjustable L Bracket for 3000 N Series Surface Armature Housing for 3000 N Series Medium magnetic lock for 3000 N, 12/24 VDC reed monitored, anodized aluminum FE322 Single Magnets - Monitored Medium magnetic lock for 3000 N, 12/24 VDC reed monitored. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Mortice 3000 N 12/24 VDC 500/250 ma Anodized aluminum 229 x 39 x 24 mm Reed FE322 FE32A FE32L FE32Z Medium Magnetic Lock for 3000 N, 12/24 VDC Reed Monitored Surface Armature Housing for 3000 N Series Adjustable L Bracket for 3000 N Series Adjustable Z Bracket for 3000 N Series

64 Magnetic Locks Page : 64 Medium Magnetic Lock for 3000 N, 12/24 VDC - Relay/LED Monitored FE323 Single Magnets - Monitored Medium magnetic lock for 3000 N, 12/24 VDC. Relay/LED monitored, anodized aluminum Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 3000 N 12/24 VDC 500/250 ma Anodized aluminum 268 x 48 x 25 mm Relay + LED FE32Z, FE32L, FE32A FE323 FE32Z FE32L FE32A Medium Magnetic Lock for 3000 N, 12/24 VDC - Relay/LED Monitored Adjustable Z Bracket for 3000 N Series Adjustable L Bracket for 3000 N Series Surface Armature Housing for 3000 N Series Surface Armature Housing for 3000 N Series FE32A Surface Armature Housing Surface Armature Housing for 3000 N series FE32A Surface Armature Housing for 3000 N Series

65 Magnetic Locks Page : 65 Adjustable L Bracket for 3000 N Series FE32L L-Bracket Adjustable L bracket for 3000 N series FE32L Adjustable L Bracket for 3000 N Series Adjustable Z Bracket for 3000 N Series FE32Z Z-Bracket Adjustable Z bracket for 3000 N series FE32Z Adjustable Z Bracket for 3000 N Series

66 Magnetic Locks Page : 66 Magnetic Lock for 6000 N - 12/24 VDC - Not Monitored FE370 Single Magnets - Not Monitored Magnetic lock for 6000 N, 12/24 VDC not monitored, aluminum housing. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Brackets Standard / surface 6000 N 12/24 VDC 500/250 ma Anodized aluminum 268 x 73 x 40 mm FE37Z, FE37L, FE37A FE370 FE37Z FE37L FE37A Magnetic Lock for 6000 N - 12/24 VDC - Not Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793) Magnetic lock for 6000 N - 12/24 VDC - Relay/LED Monitored - Anodized Aluminum FE371 Single Magnets - Monitored Magnetic lock for 6000 N, 12/24 VDC. Relay/LED monitored, aluminum housing. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 6000 N 12/24 VDC 500/250 ma Anodized aluminum 268 x 73 x 40 mm Relay + LED FE37Z, FE37L, FE37A FE371 FE37Z FE37L FE37A Magnetic lock for 6000 N - 12/24 VDC - Relay/LED Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793)

67 Magnetic Locks Page : 67 Magnetic Lock for 6000 N - 12/24 VDC - 2 Relays/LED Monitored FE372 Single Magnets - Monitored Magnetic lock for 6000 N, 12/24 VDC. 2 Relays/LED monitored, aluminum housing. Mount Holding Force Input Voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 6000 N 12/24 VDC 500/250 ma Anodized aluminum 268 x 73 x 40 mm High secure: 2 relays + LED FE37Z, FE37L, FE37A FE372 FE37Z FE37L FE37A Magnetic Lock for 6000 N - 12/24 VDC - 2 Relays/LED Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793) Magnetic Lock for 6000 N - 12/24 VDC - Not Monitored - Anodized Aluminum FE375 Dual Magnets - Not Monitored Magnetic lock for 6000 N, 12/24 VDC not monitored, aluminum housing. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Brackets Standard / surface 2 x 6000 N 12/24 VDC 2 x 500/250 ma Anodized aluminum 536 x 73 x 40 mm FE37Z, FE37L, FE37A FE375 FE37Z FE37L FE37A Magnetic Lock for 6000 N - 12/24 VDC - Not Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793)

68 Magnetic Locks Page : 68 Magnetic Lock for 6000 N - 12/24 VDC - Relays/LEDs Monitored FE376 Dual Magnets, monitored Magnetic lock for 6000 N, 12/24 VDC Relays/LED's monitored, Aluminium Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 2 x 6000 N 12/24 VDC 2 x 500/250 ma Anodized aluminum 536 x 73 x 40 mm Relay + LED FE37Z, FE37L, FE37A FE376 FE37Z FE37L FE37A Magnetic Lock for 6000 N - 12/24 VDC - Relays/LEDs Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793) Surface Armature Housing for 6000 N Series (Replaces FE793) FE37A Surface Armature Housing Surface Armature Housing for 6000 N series (Replaces FE793) FE37A Surface Armature Housing for 6000 N Series (Replaces FE793)

69 Magnetic Locks Page : 69 Adjustable L Bracket for 6000 N Series (Replaces FE790) FE37L L-bracket Adjustable L bracket for 6000 N series (Replaces FE790) FE37L Adjustable L Bracket for 6000 N Series (Replaces FE790) Adjustable Z Bracket for 6000 N Series (Replaces FE791) FE37Z Z-Bracket Adjustable Z bracket for 6000 N series (Replaces FE791) FE37Z Adjustable Z Bracket for 6000 N Series (Replaces FE791)

70 Magnetic Locks Page : 70 Electro Magnetic Shearlock - Reed Monitoring VDC FE380 Electro Magnetic Shearlock Electro Magnetic Shearlock, Reed Monitoring, VDC Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Mortice 8000 N 12 VDC 250 ma Anodized aluminum 165 x 31 x 21 mm Relay + LED FE380 Electro Magnetic Shearlock - Reed Monitoring VDC Mini Magnetic Lock for 1330 N - 12 VDC - Not Monitored - Stainless Steel Housing FE411 Single Magnets - Not Monitored Mini Magnetic lock for 1330 N, 12 VDC not monitored, stainless steel housing Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Vertical 1330 N 12 VDC 400 ma Stainless steel 162 x 32 x 23 mm FE411 Mini Magnetic Lock for 1330 N - 12 VDC - Not Monitored

71 Magnetic Locks Page : 71 Medium Magnetic Lock for 2890 N - 12/24 VDC - Not Monitored FE425 Dual Magnets - Not Monitored Medium Magnetic lock for 2890 N, 12 or 24 VDC not monitored, aluminum housing. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Brackets Standard / surface 2 x 2890 N 12/24 VDC 2 x 500/250 ma Anodized aluminum 500 x 42 x 24 mm FE480, FE481, FE482, FE483 (FE482 is Z/L kit for inswinging doors) FE425 FE480 FE481 FE482 FE483 Medium Magnetic Lock for 2890 N - 12/24 VDC - Not Monitored Adjustable L Bracket for Medium Magnets Z Bracket for Medium Magnets L and Z Kit for Inswinging Doors for Medium Magnets Surface Armature Housing for Medium Magnets Medium Magnetic Lock for 2890 N - 12/24 VDC - Monitored - Anodized Aluminum FE426 Dual Magnets - Monitored Medium magnetic lock for 2890 N, 12 or 24 VDC monitored, aluminum housing. Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 2 x 2890 N 12/24 VDC 2 x 500/250 ma Anodized aluminum 500 x 42 x 24 mm Hall effect and relay FE480, FE481, FE482, FE483 (FE482 is Z/L kit for inswinging doors) FE426 FE480 FE481 FE482 FE483 Medium Magnetic Lock for 2890 N - 12/24 VDC Monitored Adjustable L Bracket for Medium Magnets Z Bracket for Medium Magnets L and Z Kit for Inswinging Doors for Medium Magnets Surface Armature Housing for Medium Magnets

72 Magnetic Locks Page : 72 Adjustable L Bracket for Medium Magnets FE480 L-Bracket Adjustable L bracket for medium magnets FE480 Adjustable L Bracket for Medium Magnets Z Bracket for Medium Magnets FE481 Z-Bracket Z bracket for medium magnets FE481 Z Bracket for Medium Magnets

73 Magnetic Locks Page : 73 L and Z Kit for Inswinging Doors for Medium Magnets FE482 L and Z-Kit L and Z kit for inswinging doors for medium magnets. FE482 L and Z Kit for Inswinging Doors for Medium Magnets Surface Armature Housing for Medium Magnets FE483 Surface Armature Housing Surface armature housing for medium magnets FE483 Surface Armature Housing for Medium Magnets

74 Magnetic Locks Page : 74 Adhesive for Bonding Armature Housing to Glass-Tube up to 4 Strd.Mag. FE490 Adhesive Adhesive for bonding armature housing to glass, in tube up to 4 standard magnets. FE490 Adhesive for Bonding Armature Housing to Glass-Tube up to 4 Strd.Mag. Magnetic Lock for 5790 N - 12/24 VDC Dual Monitored - Anodized Aluminum FE772 Single Magnets, monitored Magnetic lock for 5890 N, 12 or 24 VDC Dual monitored, Aluminium housing Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 5790 N 12/24 VDC 500/250 ma Anodized aluminum 268 x 75 x 40 mm Dual: Reed + Hall effect and relay FE37Z, FE37L, FE37A FE772 FE37Z FE37L FE37A Magnetic Lock for 5790 N - 12/24 VDC - Dual Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793)

75 Magnetic Locks Page : 75 Magnetic Lock for 5790 N - 12/24 VDC Dual Monitored FE777 Dual Magnets - Monitored Magnetic lock for 5790 N, 12 or 24 VDC Dual monitored, aluminum housing Mount Holding force Input voltage Current draw Finish Dimensions (W x H x D) Monitoring Brackets Standard / surface 2 x 5790 N 12/24 VDC 2 x 500/250 ma Anodized aluminum 500 x 75 x 40 mm Dual: Reed + Hall effect and relay FE37Z, FE37L, FE37A FE777 FE37Z FE37L FE37A Magnetic Lock for 5790 N - 12/24 VDC Dual Monitored Adjustable Z Bracket for 6000 N Series (Replaces FE791) Adjustable L Bracket for 6000 N Series (Replaces FE790) Surface Armature Housing for 6000 N Series (Replaces FE793)

76

77 ACCESSORIES

78

79 Accessories Page : 79 Rain Protection Hood ACA000 Transparent Plexiglass Protection Hood To be installed to protect the reader or keypad from snow and rain. Dimensions (H x W x D) Weight 225 x 210 x 170 mm 200 g ACA000 ACA001 Rain Protection Hood Request to Exit Button Surface Mounted Transparent plexiglass Protects the reader from snow and rain Suitable for all readers Request to Exit Button Surface Mounted ACA001 Flush Mounted Request to Exit Button Dimensions (H x W x D) Weight 63 x 63 x 35 mm 25 g ACA001 ACA000 Request to Exit Button Surface Mounted Rain Protection Hood Flush mounted Momentary - pulse

80 Accessories Page : 80 Relay Card for Expansion of In/Outputs ACA101 Relay Card for the ACC Controllers The relay card enables expansion of the system inputs and outputs and is freely programmable via the PC software. Maximum 2 cards/controller can be fitted. Supply voltage 12 or 24 VDC (from controller - via band cable) Current consumption At 12 VDC Max. 320 ma At 24 VDC Max. 200 ma Mounting In the controller housing with enclosed mounting kit Operating temperature +5 C to +40 C Programming From PC software ACP 4W or ACP 500 W Dimensions (W x H x D) 100 x 80 x 25 mm ACA101 Relay Card for Expansion of In/Outputs Predefined outputs Plug-in connection with band cable 8 inputs, 8 outputs Power supplied from the controller Requires programming from the PC application software ACP4W or ACP500W Maximum two relay cards per controller

81 Accessories Page : 81 Wiegand interface - other readers ACA102 Wiegand Interface - Other Readers The Wiegand interface enables communication with readers on the market that produce a Wiegand code output. The interface translates the Wiegand code into the encrypted GE Security current loop protocol, allowing compatibility with the GE Security access control system. An interface has to be installed for EACH reader, so four interfaces have to be used in a four door application. This interface has been used successfully with COTAG, IDENTECH, HID and INDALA readers. Supply voltage 12 VDC (from controller) Current consumption 50 ma Mounting Enclosed housing Operating temperature +5 C to +40 C Programming Hand-held terminal or PC software Dimensions (H x W x D) 198 x 122 x 52 mm Weight 475 g ACA102 Wiegand interface - other readers Facilitates connection of other readers to the GE Security access control system Fitted in a tamper-proof box Compatible with most Wiegand communication Facilitates the use of 'existing readers and cards' in an upgraded installation

82 Accessories Page : 82 Memory Expansion Kit for ACC1 & ACC4 Controllers ACA210 Extra Logmemory to the Controllers. To increase the logmemory of the controllers. Also included is all the previously sold. ACA210 Memory Expansion Kit for ACC1 & ACC4 Controllers 1 Eprom for ACC1, release Eprom for ACC4, release 1.30 MBC ACA210 Place holders for mounting the PCB into the controller cabinet

83 Accessories Page : 83 TCP/IP Convertor Box for Converting RS232 to TCP/IP ACA300 The ACA300 Device Server The ACA300 is designed to allow devices to communicate over a standard Local Area Network (LAN) by translating RS232 / RS485 to TCP/IP and visa versa. For GE Security Access Control, this means that ACC1and ACC4 access controllers can communicate with the control software over, for example, the ethernet. Also controller loops can be connected to the network by applying a keycard (ACA201) in combination with the ACA300. Protocols supported ARP, UDP, TCP, Telnet, ICMP, SNMP, DHCP, TFTP and HTTP Device support Supports any asynchronus serial device with 7 or 8-bit data, with or without parity requiring Ethernet access Network interface RJ45 (10BASE-T) Ethernet Serial interface Female DB25 RS232 / RS422 / RS485 serial port with DCE configuration Data rates Serial speeds 300 bps to 115 Kbps Modem controls RTS, CTS, DSR, DCD, DTR Flow control Software XON/XOFF - Hardware CTS/RTS Management Internal HTTP server SNMP (read only) Serial login Telnet login Firmware Flash ROM standard Physical dimensions (H x W x D)/weight 23 x 64 x 90 mm / 350 g Shipping dimensions (H x W x D)/weight 115 x 242 x 191 mm / 1.5 kg Power requirements External adapter included Required input power of 6-9 ma max. Environmental Operating temperature +5 C to +50 C Storage temperature -40 C to +66 C Agency approvals Warranty CE, FCC B, TUV, C/UL 5-year limited warranty Converts RS232, RS485 or RS422 to TCP/IP Supports a wide range of formats The size of a match-box Supports controller and keycard connectivity to the Ethernet ACA300 TCP/IP Convertor Box for Converting RS232 to TCP/IP

84 Accessories Page : 84 Magstripe Reader Cleaning Card ACA601 Magstripe Reader Cleaning Card Cleaning card for magstripe readers to clean out the dust from the readerhead that might cause misreadings. ACA601 Magstripe Reader Cleaning Card Reader Head for Magstripe Reader ACI607 - Old Type ACA606 Service Product Reader head for magstripe reader ACI607, old type. ACA606 ACA606S18 Reader Head for Magstripe Reader ACI607 - Old Type Reader Head for Magstripe Reader ACI606S18, ACI607S18, ACI6007

85 Page : 85 Reader Head for Magstripe Reader ACI606S18, ACI607S18, ACI6007 ACA606S18 Service Product Reader head for magstripe reader ACI606S18, ACI607S18, ACI6007. ACA606S18 ACA606 Reader Head for Magstripe Reader ACI606S18, ACI607S18, ACI6007 Reader Head for Magstripe Reader ACI607 - Old Type

86 Accessories Page : 86 Surface Mounting Kit for ACI711 ACA711 Surface Mounting Kit for ACI711 A frame to be able to surface mount the reader on a wall. ACA711 Surface Mounting Kit for ACI711 Flush Mounting Kit for ACI711 ACA711U Flush Mounting Kit for ACI711 A flushmount frame to for the ACI711 reader. ACA711U Flush Mounting Kit for ACI711

87 Service Item Page : 87 PCB board of a 1 door controller unit. MBCACC1 ACC1 Mainboard Service item Current consumption ACC 1 ACC 4 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller 4 wires, twisted pair, shielded Controller to Keycard 4 wires, twisted pair, shielded Controller to PC (1 controller, max 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Communication Current loop 20 ma (with controller) MBCACC1 MBCACC1CON MBCACC4 MBCACC4CON PCB board of a 1 door controller unit. Connection Board for Controller 1 Door PCB Board of a 4 Door Controller Unit Connection Board for Controller 4 Door Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups

88 Service Item Page : 88 PCB Board of ACC1000 Incl. Mounting Spacers MBCACC1000 ACC1000 Mainboard Service item Supply voltage 12 to 24 VDC (no power supply included) Current consumption 12 VDC, 24 VDC (without slave reader) Outputs Lock relay (free switching relay C/NC/NO) Alarm relay (free switching relay C/NC/NO) programmable pulse/latch Inputs Request to exit device Current loop slave reader Operation temperature -20 C to +50 C Programming Via handheld programmer Via slave reader with keypad MBCACC1000 PCB Board of ACC1000 Incl. Mounting Spacers Mini Controller for one door Universal reading technology: magstripe, barcode, proximity, code Indoor or outdoor applications Memory for: 1,289 cards or codes, 500 last events, 100 schedules, 1 year calendar Connection Board for Controller 1 Door MBCACC1CON ACC1 Connection Board Service item MBCACC1CON MBCACC1 MBCACC4 MBCACC4CON Connection Board for Controller 1 Door PCB board of a 1 door controller unit. PCB Board of a 4 Door Controller Unit Connection Board for Controller 4 Door

89 Service Item Page : 89 PCB Board of a 4 Door Controller Unit MBCACC4 ACC4 Mainboard Service item Current consumption ACC 1 ACC 4 12 VDC / 24 VDC 240 ma / 173 ma 634 ma / 393 ma Cable Controller to Controller 4 wires, twisted pair, shielded Controller to Keycard 4 wires, twisted pair, shielded Controller to PC (1 controller, max 15 m) RS232 cable supplied with ACP 4W Operating temperature +5 C to +40 C Programming Keypad, hand-held terminal connected to the controller, PC-software, modem Communication Current loop 20 ma (with controller) MBCACC4 MBCACC4CON MBCACC1 MBCACC1CON PCB Board of a 4 Door Controller Unit Connection Board for Controller 4 Door PCB board of a 1 door controller unit. Connection Board for Controller 1 Door Reader to controller configuration Built-in communication with PC, modem or hand-held programmer Alarm arm/disarm features Built-in memory with battery backup Local memory for: - Time schedules - Users - Events - Card groups

90 Service Item Page : 90 Connection Board for Controller 4 Door MBCACC4CON ACC4 Connection Board Service item MBCACC4CON MBCACC1 MBCACC1CON MBCACC4 Connection Board for Controller 4 Door PCB board of a 1 door controller unit. Connection Board for Controller 1 Door PCB Board of a 4 Door Controller Unit

91 KEYPADS

92

93 Keypads Page : 93 Slave Keypad, Plastic Housing ACL506 Slave Keypad Multi-protocol keypad in an elegant housing protocol (CODIX, 26-bit or 30-bit Wiegand or data/clock) is set directly from the keypad. It functions as a slave connected to a host or master unit. Supply voltage 12 VAC/DC Current consumption 55 ma max Operating temperature -15 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL506 ACL507 ACL570 ACL570FI ACL570WI ACL701 ACL760 ACL770 ACL771 Slave Keypad, Plastic Housing Slave Keypad, Slim Steel Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Slave Proxreader, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing Slave Keypad/Reader, Plastic Housing Multi-protocol peripheral keypad Dust proof and water-resistant Slave keypad Indoor/outdoor Slave Keypad, Slim Steel Housing ACL507 Slave Keypad, Slim Steel Housing Mullion vandal-proof keypad with backlit metallic keys. It is equipped with photoelectric sensor that automatically adjusts illumination levels thereby effective even in low-light conditions. This multi-protocol keypad functions as a slave connected to a Host or Master unit. Protocols (CODIX, WIEGAND 26-bit or 30-bit and DATA/CLOCK) set directly from the keypad. Supply voltage 9/12 VAC/DC Current consumption 120 ma max Protection rate IP67 Operating temperature -25 C to +70 C Operating humidity 0 to 95% (non-condensing) Dimensions Cable 1 m ACL507 Slave Keypad, Slim Steel Housing ACL506 Slave Keypad, Plastic Housing ACL570 Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing ACL570FI Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount ACL570WI Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy ACL701 Slave Proxreader, Plastic Housing ACL760 Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing ACL770 Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing ACL771 Slave Keypad/Reader, Plastic Housing Multi protocol peripheral unit (Wiegand 26-bit / 30-bit, data/clock, CODIX) Dust proof and water-resistant Slave keypad Indoor/outdoor

94 Keypads Page : 94 Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing ACL570 Stand-Alone Keypad With 99 Codes Stand-alone and robust keypad with backlit keys for access control and home automation. In aesthetically designed housing, ACL570-serie can be surface or flush mounted and is available in different colours. It has 99 user-memory, 2 relay outputs and 2 exit buttons. CODIX bus allows for networking with the readers for two-door control. Supply voltage Current consumption Outputs Relays LED Buzzer 12/24 VAC/DC 120 ma max 2 relay Latch or pulsed mode (01 to 99 seconds) Bi-coloured (red/green), yellow and red One internal buzzer Operating temperature -25 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL570 ACL570FI ACL570WI ACL506 ACL507 ACL701 ACL760 ACL770 ACL771 Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Slave Keypad, Plastic Housing Slave Keypad, Slim Steel Housing Slave Proxreader, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing Slave Keypad/Reader, Plastic Housing Indoor/outdoor Dust proof and water-resistant Up to 99 user codes Up to 2 peripherals (keypad/proximity reader) can be connected Codes can be 1 to 8 digit long

95 Keypads Page : 95 Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount ACL570FI Stand-Alone Keypad With 99 Codes Stand-alone and robust keypad with backlit keys for access control and home automation. In aesthetically designed housing, ACL570-serie can be surface or flush mounted and is available in different colours. It has 99 user memory, 2 relay outputs and 2 exit buttons. CODIX bus allows for networking with the readers for two-door control. Supply voltage Current consumption Outputs Relays LED Buzzer 12/24 VAC/DC 120 ma max 2 relay Latch or pulsed mode (01 to 99 seconds) Bi-coloured (red/green), yellow and red One internal buzzer Operating temperature -25 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL570FI ACL570WI ACL506 ACL507 ACL570 ACL701 ACL760 ACL770 ACL771 Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Slave Keypad, Plastic Housing Slave Keypad, Slim Steel Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing Slave Proxreader, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing Slave Keypad/Reader, Plastic Housing Indoor/outdoor Dust proof and water-resistant Up to 99 user codes Up to 2 peripherals (keypad/proximity reader) can be connected Codes can be 1 to 8 digit long

96 Keypads Page : 96 Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy ACL570WI Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Stand-alone and robust keypad with backlit keys for access control and home automation. In aesthetically designed housing, the ACL570 series can be surface or flush mounted and is available in different colours. It has 99 user memory, 2 relay outputs and 2 exit buttons. CODIX bus allows for networking with the readers for two-door control. Supply voltage Current consumption Outputs Relays LED Buzzer 12/24 VAC/DC 120 ma max 2 relay Latch or pulsed mode (01 to 99 seconds) Bi-coloured (red/green), yellow and red One internal buzzer Operating temperature -25 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL570WI ACL506 ACL507 ACL570 ACL570FI ACL701 ACL760 ACL770 ACL771 Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Slave Keypad, Plastic Housing Slave Keypad, Slim Steel Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount Slave Proxreader, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing Slave Keypad/Reader, Plastic Housing Indoor/outdoor Dust proof and water-resistant Up to 99 user codes Up to 2 peripherals (keypad/proximity reader) can be connected Codes can be 1 to 8 digit long

97 Readers Page : 97 Slave Proxreader, Plastic Housing ACL701 Multi-protocol Compact Proximity Reader Resin potted reader, with 8-core cable that reads EM4x02 compatible cards/tags and a read range of up to 12 cm. It is a slave unit and is intended to be connected to a host or master unit. Supply voltage 8-20 VAC/DC Current consumption 35 ma max Read range 6-12 cm Protection rate IP67 Operating temperature -15 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL701 ACL760 ACL770 ACL771 ACL506 ACL507 ACL570 ACL570FI ACL570WI Slave Proxreader, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing Slave Keypad/Reader, Plastic Housing Slave Keypad, Plastic Housing Slave Keypad, Slim Steel Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Multi-protocol reader Potted 2 free LED to control Buzzer

98 Keypads Page : 98 Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing ACL760 Stand-Alone Keypad With 99 Codes Mullion vandal-proof stand-alone and potted keypad with backlit metallic keys. ACL760 with user memory of 99 and 2 outputs with 1 exit button is the best choice for single door access control. Photoelectric sensor automatically adjusts the backlighting. Supply voltage Current consumption Outputs Relays LED Buzzer 12/24 VAC/DC 70 ma max 1 relay and 1 transistors Latch or pulsed mode (01 to 99 seconds) Bi-coloured (red/green), yellow and red One internal buzzer Operating temperature -25 C to +70 C Operating humidity 0 to 95% (non-condensing) Dimensions Cabel 3 m ACL760 Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing ACL770 Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing ACL771 Slave Keypad/Reader, Plastic Housing ACL506 Slave Keypad, Plastic Housing ACL507 Slave Keypad, Slim Steel Housing ACL570 Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing ACL570FI Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount ACL570WI Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy ACL701 Slave Proxreader, Plastic Housing Indoor/outdoor Dust proof and water-resistant Up to 99 user codes Up to 3 peripherals (keypad/proximity reader) can be connected Codes can be 1 to 8 digit long

99 Keypads Page : 99 Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing ACL770 Stand-Alone Keypad/Reader with 300/600 Codes A stand-alone keypad with integrated proximity reader in a modern housing with 200 user memory. Increased user flexibility via the choice of codes, key fobs or cards. ACL770 can be easily networked to the peripherals via the CODIX bus. Supply voltage Current consumption Outputs Relays LED Buzzer 12 VAC/DC 65 ma max 1 relay and 2 transistors Latch or pulsed mode (01 to 99 seconds) Bi-coloured (red/green), yellow and red One internal buzzer Operating temperature -15 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL770 Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing ACL771 Slave Keypad/Reader, Plastic Housing ACL506 Slave Keypad, Plastic Housing ACL507 Slave Keypad, Slim Steel Housing ACL570 Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing ACL570FI Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount ACL570WI Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy ACL701 Slave Proxreader, Plastic Housing ACL760 Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Indoor/outdoor Dust proof and water-resistant User memory 600 (code or card/tag) or 300 (code + card/tag) Up to 3 peripherals (keypad/proximity reader) can be connected Codes up to 8 digits long (100 million possible code combinations)

100 Keypads Page : 100 Slave Keypad/Reader, Plastic Housing ACL771 Slave Keypad/Reader Multi-protocol keypad with proximity technology. Protocols (26-bit Wiegand or 30-bit Wiegand or data/clock) set directly from the keypad. ACL771 functions as a slave connected to a host or master unit. It only reads EM4x02 compatible cards or key fobs. Supply voltage 12 VAC/DC Current consumption 40 ma max Operating temperature -15 C to +60 C Operating humidity 0 to 95% (non-condensing) Dimensions ACL771 ACL506 ACL507 ACL570 ACL570FI ACL570WI ACL701 ACL760 ACL770 Slave Keypad/Reader, Plastic Housing Slave Keypad, Plastic Housing Slave Keypad, Slim Steel Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Flush Mount Stand-Alone Keypad With 99 Codes, 2 Relays, Aluminium Alloy Slave Proxreader, Plastic Housing Stand-Alone Keypad With 99 Codes, 2 Relays, Slim Steel Housing Stand-Alone Keypad/Reader, 300/600 Codes, 2 Relays, Plastic Housing Slave keypad/reader Multi protocol peripheral keypad with integrated proximity reader Reads EM4x02 compatible cards, key fobs

HID Proximity Credentials

HID Proximity Credentials HID Proximity Credentials ProxCard II Value priced 125 khz proximity card Base Part Number 1326 Price competitive with all other card technologies Thin enough to carry in a wallet or purse ISOProx II 125

More information

HID Proximity. 125 khz Cards and Readers ACCESS SECURE IDENTITY

HID Proximity. 125 khz Cards and Readers ACCESS SECURE IDENTITY HID Proximity 125 khz Cards and Readers ACCESS SECURE IDENTITY HID Proximity 125 khz Proximity Cards and Readers For security managers, dealers, integrators and OEMs, HID proximity cards and readers are

More information

HID Proximity. 125 khz Cards and Readers ACCESS SECURE IDENTITY

HID Proximity. 125 khz Cards and Readers ACCESS SECURE IDENTITY HID Proximity 125 khz Cards and Readers ACCESS SECURE IDENTITY HID Global is focused on creating customer value as the trusted source for products, services and know-how related to the delivery of secure

More information

Electronic Access Control Catalogue. Field Devices

Electronic Access Control Catalogue. Field Devices Electronic Access Control Catalogue Field Devices Issue: January 2007 TAC the Single Source for all Your Electronic Access Needs This catalogue presents the electronic access control portfolio offered

More information

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices Section A3 This Price Schedule is effective January 1, 2018. Date Page Comment 1-1-18 All January, 2018 Price Schedule update. 3-21-18 21 Added 1804-701, 1804-705, 1804-706 LED retrofit kits. 4-24-18 25

More information

January 2019 PRICE SCHEDULE A 2.0 Access Control Devices

January 2019 PRICE SCHEDULE A 2.0 Access Control Devices January 2019 PRICE SCHEDULE A 2.0 Section A3 This Price Schedule is effective January 7, 2019. Date Page Comment 1-2-19 All January, 2019 Price Schedule update. 2-5-19 13 Corrected information listed under

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

A

A 1 www.axxessid.com Introduction Established in 1994, Axxess Identification offers the world s most innovative access control products. Significant company resources have been invested in the research and

More information

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15

More information

Introduction to HID Radio Frequency Identification (RF ID)

Introduction to HID Radio Frequency Identification (RF ID) Application Note 004 Introduction to HID Radio Frequency Identification (RF ID) HID is the future of Access Control Access Control Systems are used to allow authorized people to enter a controlled area

More information

ACTsmart2 Product Range Operating and Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions ACTsmart2 Product Range Operating and Installation Instructions 18-00045 Contents ORDERING INFORMATION......4 INSTALLATION NOTES......5 IMPORTANT......5 PRODUCT SPECIFICATION......5 30 SECOND PROGRAMMING

More information

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL 1 Access Control Starter Kit in-a-box 3 2 5 SIMPLE... EVERYTHING YOU NEED FOR A COMPLETE SYSTEM SCALABLE...

More information

Choose Cotag readers. ...For ultimate convenience and cost-efficiency.

Choose Cotag readers. ...For ultimate convenience and cost-efficiency. Choose Cotag readers...for ultimate convenience and cost-efficiency. SiPass readers Robust, reliable and easy to use Siemens provides a wide range of readers to satisfy the access control requirements

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM System versions Standalone controllers series based on integrated models KZ-400, 500, 600, 700, KZC-300,800, 900 KaDe Lite system based on integrated controllers KZ-1000 KaDe Premium

More information

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control January 2013 PRICE SCHEDULE A 2.0 Section A4 Date Page Comment 1 1 13 All January, 2013 Price Schedule update. 2 13 13 6 Removed 1812 092 from 1812 145 kit. Added 1812 092 to 1812 147 kit. 2 13 13 9 P/N

More information

125 khz Proximity Physical Access How to Order Guide

125 khz Proximity Physical Access How to Order Guide 125 khz Proximity Physical Access How to Order Guide D00530, Release A.6 December 1, 2008 The most current version of this document is always available for download at: www.hidcorp.com/support To check

More information

January 2013 PRICE SCHEDULE A 2.0 PC Programmable Telephone Entry & Access Control. PC Programmable Telephone Entry & Access Control

January 2013 PRICE SCHEDULE A 2.0 PC Programmable Telephone Entry & Access Control. PC Programmable Telephone Entry & Access Control January 2013 PRICE SCHEDULE A 2.0 Section A3 Date Page Comment 10-1-13 All October, 2013 Price Schedule update. 1-25-13 18 Added part numbers to TagMaster products. 2-13-13 9 Removed wireless wiegand devices

More information

It s not. just for opening doors anymore. Reader Reference Guide CONTACTLESS TECHNOLOGY: iclass

It s not. just for opening doors anymore. Reader Reference Guide CONTACTLESS TECHNOLOGY: iclass Reader Reference Guide CONTACTLESS TECHLOGY: It s not just for opening doors anymore. HID s contactless readers are convenient, secure, and versatile: standalone access control pc-based access control

More information

IntelliPr ox 2000 KEYLESS ENTRY SYSTEM TO MANAGE ACCESS TO A SINGLE DOOR FOR UP TO 500 USERS NOW WITH D-LITE SOFTWARE

IntelliPr ox 2000 KEYLESS ENTRY SYSTEM TO MANAGE ACCESS TO A SINGLE DOOR FOR UP TO 500 USERS NOW WITH D-LITE SOFTWARE The Best Proximity Technology At A Revolutionary Price IntelliPr ox 2000 KEYLESS ENTRY SYSTEM TO MANAGE ACCESS TO A SINGLE DOOR FOR UP TO 500 USERS NOW WITH D-LITE SOFTWARE Superior proximity technology

More information

CARD? INSIDE. What s. your. Credential Reference Guide HID CARD TECHNOLOGIES HID CARD SERVICES CARD APPLICATIONS

CARD? INSIDE. What s. your. Credential Reference Guide HID CARD TECHNOLOGIES HID CARD SERVICES CARD APPLICATIONS Credential Reference Guide What s HID CARD TECHLOGIES proximity magnetic stripe contact smart chip contactless smart chip contactless memory module (MIFARE ) Wiegand Swipe HID CARD SERVICES custom configuration

More information

Electronic Access Control Catalogue

Electronic Access Control Catalogue Electronic Access Control Catalogue Issue September 2010 Make the most of your energy 2 Schneider Electric the Single Source for all Your Electronic Access Needs This catalogue presents the electronic

More information

GE Security Smart Cards & T-7xx Readers How to Order Guide PN: HTOG

GE Security Smart Cards & T-7xx Readers How to Order Guide PN: HTOG GE Security Smart Cards & T-7xx Readers PN: HTOG-090512 Date: May 2009 GE Security Smart Cards & Readers Page 2 Table of Contents GE Security... 1 Smart Cards & T-7xx Readers... 1... 1 Overview... 3 Smart

More information

Wiegand & Magnetic Stripe How to Order Guide

Wiegand & Magnetic Stripe How to Order Guide Wiegand & Magnetic Stripe How to Order Guide D00534, Release A.6 July 6, 2009 The most current version of this document is always available for download at: http://www.hidglobal.com/documents/wiegand_magstripe_htog_en.pdf

More information

PRO3200 Professional Modular Access Control Hardware

PRO3200 Professional Modular Access Control Hardware PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing

More information

January 2013 PRICE SCHEDULE A 2.0. PC Programmable Telephone Entry & Access Control

January 2013 PRICE SCHEDULE A 2.0. PC Programmable Telephone Entry & Access Control January 2013 PRICE SCHEDULE A 2.0 Section A3 Date Page Comment 10 1 13 All October, 2013 Price Schedule update. 1 25 13 18 Added part numbers to TagMaster products. 2 13 13 9 Removed wireless wiegand devices

More information

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Installation Manual - 5365-902 Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B Web page, E-mail - www.prox.com MiniProx Reader Installation Manual 5365-902 REV D 1 of 7 MiniProx Reader

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

ACCESS CONTROL ACC. CONTROL

ACCESS CONTROL ACC. CONTROL ACCESS CONTROL the Logica group - catalog 2005 1 2 the Logica group - catalog 2005 ACCESS PACKAGES LAC2200 LAC2400 LAC2450 TWO DOOR PACKAGE Entry level Access Control System includes 2 Door/2 Reader Controller,

More information

Section A3 PC Programmable Telephone Entry & Access Control For current pricing, please use our Dealer Portal. Date Page Comment

Section A3 PC Programmable Telephone Entry & Access Control For current pricing, please use our Dealer Portal. Date Page Comment April 2015 Section A3 For current pricing, please use our Dealer Portal. http://doorking.com/dealer-distributor Date Page Comment 4-1-15 All April, 2015 reference guide update. Specifications subject to

More information

multiclass MHz Contactless and 125 khz Proximity Cards and Readers

multiclass MHz Contactless and 125 khz Proximity Cards and Readers multiclass 13.56 MHz Contactless and 125 khz Proximity Cards and Readers With our unique card technology read selection feature, customers have endless card management flexibility, with security and simplicity.

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

HID Products. Quick Reference Guide

HID Products. Quick Reference Guide HID Products Quick Reference Guide Edge IP-Based Access Control Solutions Edge EdgeReader Solo EdgeReader EdgeReader Writer EdgeReader Multi-Class EdgeReader Solo Multi-Class EdgePlus Solo Part ESR40 ER40

More information

WRI400 WIRELESS READER INTERFACE

WRI400 WIRELESS READER INTERFACE WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 March 12 Technical Services Engineering Support 1 Training Overview WRI400 Description Information Installation

More information

PRO2200 Professional Modular Access Control Hardware

PRO2200 Professional Modular Access Control Hardware PRO2200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO2200 professional modular access control hardware is an advanced access control panel capable of providing

More information

TAC I/NETTM 1284, 1280, Security Control Unit

TAC I/NETTM 1284, 1280, Security Control Unit TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring

More information

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have. Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom

More information

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers NetGen Hardware Installation Guide for NetGen Ethernet Door Controllers 0613 Table of Contents BLUEWAVE SYSTEM OVERVIEW...2 THE WI-FI LOCK AND SECURITY COMPANY...2 NETGEN DOOR CONTROLLERS...2 INSTALLATION

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced

More information

Pyramid Series Proximity Readers

Pyramid Series Proximity Readers The Proximity line of OEM Proximity Readers can be used with virtually any manufacturer's access panel because the readers produce industry standard pass-through Wiegand (26-bit or custom formats) or magnetic

More information

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX ISC910-1-0-GB-XX ISC911-5-0-GB-XX ISC920-0-0-GB-XX ISC921-5-0-GB-XX The ImproX IXP20 is a fully featured, stand-alone Access Control System supporting up to 1 000 Tagholders and 5 000 transactions. Designed

More information

Proximity Card and Pin Reader Installation Manual

Proximity Card and Pin Reader Installation Manual Multi Prox Proximity Card and Pin Reader Installation Manual PUBLICATION INFORMATION 60A9 - Draft Release Version 0.1.2 71D0 - Version 1.0.5 CONTENTS Introduction... 1 Legend... 2 Terminology... 2 Mounting...

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

ACTPRO ACCESS CONTROL. Specification Guide

ACTPRO ACCESS CONTROL. Specification Guide ACTPRO ACCESS CONTROL Specification Guide Table of Contents Glossary of Terms... 2 General System Specification Overview... 3 Hardware Requirements... 4 Four Door IP Controller... 4 Two Door IP Controller...

More information

OEM Proximity Reader with Keypad Manual REV1

OEM Proximity Reader with Keypad Manual REV1 484-52 OEM Proximity Reader with Keypad Manual REV1 Overview The 484-52 proximity keypad reader provides pin code identification to be used together with a proximity identification card. The 484-52 consists

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

_ Access control SISTEMAS DE SEGURIDAD

_ Access control SISTEMAS DE SEGURIDAD _ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams

More information

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N) Touch & No Touch Exit Buttons s Infra-Red No Touch Exit Buttons ADB-11-CO (No Touch)/ ADB-13-CO (Hand icon) - 86x86x39mm - Sensing distance: 0.1-15cm - Installation: use with 86*86 back box ADB-12-CO (No

More information

KANTECH SPECIAL READERS POLARIS MAGSTRIPE READERS TECHNICALTIP

KANTECH SPECIAL READERS POLARIS MAGSTRIPE READERS TECHNICALTIP 336 Part No P600 P600/P325XSF/P225XSF P325KPXSF/P225KPW26 P10SHL P325XSF P225XSF P325KPXSF P225KPW26 IOPROX READERS P225XSF 0251660 IOPROX reader MULLION XSF format, typical read range up to 16.5cm, dimensions:

More information

2012 ACCESS CONTROL PROXIMITY KEYPAD FINGERPRINT BLUETOOH RADIO FREQUENCY COMBINED

2012 ACCESS CONTROL PROXIMITY KEYPAD FINGERPRINT BLUETOOH RADIO FREQUENCY COMBINED 01 ACCESS CONTROL PROXIMITY KEYPAD FINGERPRINT BLUETOOH RADIO FREQUENCY COMBINED INDEX QUICK GUIDE 0 STAND-ALONE 04 CENTRALIZED 36 ACCESSORIES 86 INDEX OF REFERENCES 94 QUICK GUIDE OF REFERENCES KEYPAD

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

ACCESS CONTROL Products 2017

ACCESS CONTROL Products 2017 Page 1 of 8 NESS Access Controllers 101-102 NESS MCP-040 ACCESS CONTROLLER Including 12V 6A power supply and high-tech metal housing Supports 4 x Wiegand Readers Supports 8 x RS-485 Readers 4 Lock Outputs

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox standalone ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox ACT 5e prox 2R.indd 1 19/02/2016 17:05:06 ACTstandalone Robust and Reliable. 1 ACT 5e prox 2R.indd 2 19/02/2016

More information

MS-3000 MicroStar Reader

MS-3000 MicroStar Reader MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.

More information

Biometrics. Biometrics

Biometrics. Biometrics Biometrics Biometrics This section of the Electronic Access Control catalog covers HandKey biometric hand geometry readers and other accessories that can be easily integrated into an access control system.

More information

RFID PRODUCT AND SYSTEM

RFID PRODUCT AND SYSTEM EL500(T)-X-XX Access control system, EM125kHz technology EL500-X-0C EL500-X-1C EL500-X-0D Economic access control system, EM125kHz technology Economic access control system, EM125kHz technology, with keypad

More information

EntryProx Quick Start Guide

EntryProx Quick Start Guide This guide provides quick info on how to add or delete cards, print transactions, and change the main relay timer. For installation details or advanced programming, see the complete user s guide, part

More information

Access Easy Controller 2.1

Access Easy Controller 2.1 Systems Access Easy Controller 2.1 Access Easy Controller 2.1 4 access Wiegand readers expandable to 16 Capacity up to 20,480 card holders and 100,000 transactions Classify cardholders based on 254 access

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

The Future of Proximity Access Control

The Future of Proximity Access Control The Future of Proximity Access Control The PXL-250 Tiger Controller cuts the cost of proximity access control in half, not just the equipment cost, but the total installed cost due to some great installer

More information

Hi-tech. Advanced. Multifaceted. These are some of the terms that best describe our diverse range of access control offerings.

Hi-tech. Advanced. Multifaceted. These are some of the terms that best describe our diverse range of access control offerings. ACCESS CONTROL traffic barriers Hi-tech. Advanced. Multifaceted. These are some of the terms that best describe our diverse range of access control offerings. SOLO Standalone Product Code: SOLO0001V1_AU

More information

Hybrid Security & Automation Platform

Hybrid Security & Automation Platform Hybrid Security & Automation Platform MARKETS: BUILDER MARKET Today s new home buyers are looking for technology in their homes now more than ever. Vario is designed to offer modern security allowing homes

More information

VICON ACCESS CONTROL CONTROLLERS

VICON ACCESS CONTROL CONTROLLERS VICON ACCESS CONTROL CONTROLLERS Also available in white Over-the-Door Controller Master Controller Multi-Door Kit Elevator/IO Controller Product at a Glance The Vicon Access Control (VAX) system consists

More information

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz SPX-5000 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5601 2.4GHz RPT-5651 2.4GHz Repeater SPX-5521 900 Mhz IOX-7621 2.4GHz EXP-2000 SPX-6601 2.4GHz SPX-5000_MAN_082112 This

More information

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316 CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

Multi-Technology Proximity Reader

Multi-Technology Proximity Reader MultiProx Multi-Technology Proximity The MultiProx makes it possible to replace an existing Schlage/ Westinghouse card access control system with any Wiegand protocol system while maintaining your existing

More information

Installation & User Manual V1.0

Installation & User Manual V1.0 Other products from GSD standalone products GSD also offers fully functional standalone door controls for less complex door management. This attractive design, with modern aesthestics, will complement

More information

Smart access control and door entry systems. Product Selection Guide

Smart access control and door entry systems. Product Selection Guide 2018 Smart access control and door entry systems Product Selection Guide 2 Contents 3 Networked Access Control Our networked access control system, Net2, is administered using one or more PCs and can be

More information

Aceprox FSK Proximity Reader REV2 Data Sheet

Aceprox FSK Proximity Reader REV2 Data Sheet Aceprox 688-52 FSK Proximity Reader REV2 Data Sheet Overview The 688-52 OEM proximity reader consists of three parts: a potted unit containing the electronics, a front cover, and an optional spacer plate.

More information

DESIGN GUIDE FOR INFINITY SYSTEMS

DESIGN GUIDE FOR INFINITY SYSTEMS Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

MS-7000: SuperStar Reader

MS-7000: SuperStar Reader The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Multi Card Technology

Multi Card Technology PRX-TSEC tsec Card Reader Sleek and stylish, and with a range of optional features, the tsec series has a solution for everyone. Available in three sizes, multiple card capabilities, with an optional keypad,

More information

With INTRATONE, you can easily secure all kinds of access points. You choose the management mode

With INTRATONE, you can easily secure all kinds of access points. You choose the management mode With INTRATONE, you can easily secure all kinds of access points (Car parks, isolated doors, pedestrian gates, etc.) You choose the management mode REAL-TIME and REMOTE USING GSM READ/WRITE MODE How does

More information

MS-5000: MiniStar Reader

MS-5000: MiniStar Reader The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also

More information

Frequently asked Questions:

Frequently asked Questions: COMPANY Frequently asked Questions: Who is RF IDeas? RF IDeas is an industry leader in the design, development and manufacturing of proximity and contactless reader/writer solutions. We enhance and expand

More information

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory. 1 EXpert Based Access Control System - Overview TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory. EXpert2 is capable of controlling 2 doors with the

More information

PXL-250 Tiger Controller

PXL-250 Tiger Controller PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

Intelligent Four Lift Controller TS0869

Intelligent Four Lift Controller TS0869 The is a powerful real time lift controller for extensive multi level buildings requiring floor access control. The handles 4 lifts and access to 64 floors on each lift. CONNECTIVITY The can control 4

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

Product Guide. Access Control. Composite All-In-One Cable, Reader Cables, and Accessory Cables.

Product Guide. Access Control. Composite All-In-One Cable, Reader Cables, and Accessory Cables. Product Guide Access Control Composite All-In-One Cable, Reader Cables, and Accessory Cables www.westpennwire.com 1 Systems Access Control Systems An access control system is an integration of hardware,

More information

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board *P516-097* P516-097 PIB300 and PIB301 User Guide Installation and operation instructions for Panel Interface Board Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française,

More information

Camden - Key Switches

Camden - Key Switches - Key Switches CM1120 - Flush Mount Key Switch 1 SPDT Momentary CM1130 - Flush Mount Key Switch 1 SPDT Maintained CM1120 CM1120 CM1120 CM2020 - Narrow Style Key Switch 1 SPDT Momentary CM2030 - Narrow

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

GE Security CONTROLS & COMMUNICATIONS. Product Catalogue

GE Security CONTROLS & COMMUNICATIONS. Product Catalogue G Security CONTROLS & COMMUNICATIONS Product Catalogue In this catalogue you will find a wide range of Controls & Communications equipment from G Security. G Security is a global technology leader dedicated

More information

SiPass Entro. Open the door to comprehensive security.

SiPass Entro. Open the door to comprehensive security. Open the door to comprehensive security. Comprehensive access control SiPass Entro is a very scalable, flexible, and user-friendly access control system that can monitor and control access to facilities

More information

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features Audio Door Entry with Access Control ACTentry A5 Kit Audio Door Entry & Access Control Kit Each kit comprises a door entry panel intercom power supply unit ACTEntryA5ICOM-K ACTentry A5 Entry Panel Audio

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

VANDERBILT PRODUCT CATALOGUE

VANDERBILT PRODUCT CATALOGUE VANDERBILT PRODUCT CATALOGUE Panels & Keypads Standalone single- Door Solutions Readers & Controllers ACTsmart Readers & Controller Flush or surface mounted digital Keypad polycarbonate housing, IP67 Proximity

More information