1 Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated:
2 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact your system installer. Your installer is familiar with your system configuration and should be able to answer any of your questions. Should you need additional information, please call our Technical Support Help Desk, Monday to Friday 9:00 AM to 6:00 PM (GMT +8:00) Method Details Phone + 60 (3) Fax + 60 (3) Internet support@entrypass.net 1
3 Considerations Prior to Installation Preparing Your EntryPass Controllers EntryPass controller contains numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Thus, prior to installation, please follow the instruction below: Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precautions at all Visually ensure no onboard parts is broken, damage or contains burn mark Do not turn on the power supply until you completed all wiring and external add on devices installations CAUTION Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. To prevent a risk of explosion do not pry the battery out with a metal or conductive tool. Instances of Non-Warranty Damage due to natural disaster, accident or human cause. Damage as a result of violating the conditions recommended in the user manual Damage due to improper installation Damage due to use of uncertified components Damage due to use exceeding the permitted parameters 2
4 Product Description NMiNi 2 Reader NMiNi 2 DRB 3
5 Product Description (NMiNi2 Reader) Color LCD Screen Heartbeat/Indication Tricolor LED CapSense Touch Button with Backlight 4
6 Connector Description (NMiNi2 Reader) Tamper Switch Rear View of NMiNi2 Reader CN3 Color Description: 1. Red: 12V 2. Orange: 12V 3. Black: GND 4. Brown: GND 5. Yellow: - 6. Blue: - 7. Green: C2-8. White: C2+ CN2 Color Description: 1. Green: C1-2. White: C1+ 3. Red: - 4. Brown: - 5. Orange: RJ45 Jack Pin 2 6. Blue: RJ45 Jack Pin 1 7. Black: RJ45 Jack Pin 3 8. Yellow: RJ45 Jack Pin 6 PIN8 - Brown CN3 CN2 CN2 CN2 CN2 CN2 PIN6 - Yellow PIN3 - Black PIN2 - Orange PIN1 - Blue PIN7 - BrownWhite PIN6 - Green PIN5 - BlueWhite PIN4 - Blue PIN3 - GreenWhite PIN2 - Orange PIN1 - OrangeWhite RJ45(Female) Jack Straight Cable RJ45(Male) Plug 5
7 Component Description (NMiNi2 DRB) JP6: Vout 2 - Supply Voltage Selector 2 Reset Switch Cold Start Switch Heartbeat LED MCU JP5: Vout 1 - Supply Voltage Selector 1 Buzzer COM Chip RS232 COMs COM Rx/Tx LEDs Relay 1 LED Relay 1 Relay 2 Relay 2 LED PCB Version Cold Start, Factory Default and Crypto Key reset Selection Jumper Address Dip Switch Supply Voltage Selector: 12V 5V 12V 5V JP5 V out1 JP6 V out2 Position of Dip Switch on DRB PCB Version: DRB-04-PCB Position of Dip Switch on DRB PCB Version: DRB-05-PCB and above Put the jumper cap at JP5 1-2 to output 12VDC at Vout 1 Put the jumper cap at JP5 2-3 to output 5VDC at Vout 1 Put the jumper cap at JP6 1-2 to output 12VDC at Vout 2 Put the jumper cap at JP6 2-3 to output 5VDC at Vout ON ON
8 Connector Legend Description (NMiNi2 DRB) +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Power Supply Connector Relay 1 Relay 2 AC Fail Connector Input 1, 2, 3, 4 +12V - Power Supply Positive 12V DC GND - Power Supply Ground EARTH - Power Supply Earth NC1 - Relay 1 Normally Close Connection CM1 - Relay 1 Common Input NO1 - Relay 1 Normally On Connection NC2 - Relay 2 Normally Close Connection CM2 - Relay 2 Common Input NO2 - Relay 2 Normally On Connection ACC - AC Fail Monitoring BATT - Backup Battery Monitoring IN1 - Input 1 IN2 - Input 2 GND - Ground IN3 - Input 3 IN4 - Input 4 GND - Ground GND - Ground GND - Ground 7
9 Connector Legend Description (NMiNi2 DRB) Voltage Supply Reader 1 Reader Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 - Voltage Supply 1 GND - Voltage Supply Ground Vout2 - Voltage Supply 2 RD01 - Reader 1 Data 0 Input RD11 - Reader 1 Data 1 Input GRN1 - Reader 1 Green LED RED1 - Reader 1 RED LED BZR1 - Reader 1 Buzzer TMP1 - Reader 1 Tamper RD02 - Reader 2 Data 0 Input (Reserved) RD12 - Reader 2 Data 1 Input (Reserved) GRN2 - Reader 2 Green LED (Reserved) RED2 - Reader 2 RED LED (Reserved) BZR2 - Reader 2 Buzzer (Reserved) TMP2 - Reader 2 Tamper (Reserved) C1+ - COM1 (+) Connection C1- - COM1 (-) Connection C2+ - COM2 (+) Connection (Reserved) C2- - COM2 (-) Connection (Reserved) 8
10 Power Supply Unit Specification ENTRYPASS Power Supply Unit Specification: Switching Power Supply 12V DC 3 Amp (Minimum) 9
11 Connecting the NMiNi2 Reader and DRB NMiNi2 +12V - Power Supply Positive 12V DC -12V/GND - Power Supply Ground ETH - Power Supply Earthing (If Required) ACC - AC Fail Monitoring BAT/BS - Backup Battery Monitoring Power Supply BATT/BS/VS PG GND ENTRYPASS 12V+ GND C1+ C1- BAT/BS (Backup Battery Monitoring) point will monitor the backup battery voltage which will supply power to the board when AC power is cut off. The minimum voltage for cutoff while using backup battery is 8.4V 12V+ Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1+ C1 C2+ C2 Vout1 Vout2 Buzzer RST COLD HRT MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 GND-ETH Relay 1 Relay 2 Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND 10
12 Connecting NMiNi2 Reader and DRB Dip Switch Addressing ON Addr: Note: Please identify the PCB version of DRB board for correct Dip Switch Orientation (refer page 6) The dipswitch is used for setting the unit address of the DRB to match the RDK Each switch is represent by an address, the sum of the switch address will be the controller address The number in RED color is the address of each individual switch of the dip switch Example: To obtain Address 11, = 11, So just switch on switch 1, 2, 4 Note: Factory Default Unit Address of NMINI2 Reader is 000 To configure the unit address of NMINI2, please go to: System > System Setting > Unit Address 11
13 Connecting NMiNi2 Reader and DRB Dip Switch Addressing Unit Address Switch 1 Switch 2 Switch 3 Switch 4 Switch OFF OFF OFF OFF OFF 001 ON OFF OFF OFF OFF 002 OFF ON OFF OFF OFF 003 ON ON OFF OFF OFF 004 OFF OFF ON OFF OFF 005 ON OFF ON OFF OFF 006 OFF ON ON OFF OFF 007 ON ON ON OFF OFF 008 OFF OFF OFF ON OFF 009 ON OFF OFF ON OFF 010 OFF ON OFF ON OFF 011 ON ON OFF ON OFF 012 OFF OFF ON ON OFF 013 ON OFF ON ON OFF 014 OFF ON ON ON OFF 015 ON ON ON ON OFF 016 OFF OFF OFF OFF ON Binary to Decimal Addressing Table 12
14 Connecting NMiNi2 Reader and DRB Dip Switch Addressing Unit Address Switch 1 Switch 2 Switch 3 Switch 4 Switch ON OFF OFF OFF ON 018 OFF ON OFF OFF ON 019 ON ON OFF OFF ON 020 OFF OFF ON OFF ON 021 ON OFF ON OFF ON 022 OFF ON ON OFF ON 023 ON ON ON OFF ON 024 OFF OFF OFF ON ON 025 ON OFF OFF ON ON 026 OFF ON OFF ON ON 027 ON ON OFF ON ON 028 OFF OFF ON ON ON 029 ON OFF ON ON ON 030 OFF ON ON ON ON 031 ON ON ON ON ON Binary to Decimal Addressing Table 13
15 Connecting the Lock (Normally Closed - NC), Breakglass and Keyswitch +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND 12V+ GND PSU 12V DC Break Glass Key Switch 12V+ GND Electro-Magnetic Lock or Drop Bolt Diode(1N4002) must be installed at the locking devices in order to protect against back EMF It is advisable to connect EM lock COM to 12V+ of Power Supply 14
16 Connecting the Striker Lock or Drop Bolt (Normally Open - NO) +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND PSU 12V DC 12V+ GND 12V+ GND Electro-Strike Lock Diode(1N4002) must be installed at the locking devices in order to protect against back EMF 15
17 Connecting the Door Sensor and Door Release Button/Push Button +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND IN1 IN2 GND Door Sensor Push Button 16
18 Connecting the Reader MiNi as Reader Red: 12V+ Black: GND Orange: D0 Yellow: D1 To configure MINI as a READER Mode, press: F Enter 01 Enter 05 Enter 1 Enter ESC x3 MiNi as Reader Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 17
19 Connecting the Reader 3 rd Party Reader Red: 12V+ Black: GND Green: D0 White: D1 Green LED Buzzer Tamper Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Put the jumper cap at JP5 1-2 to output 12VDC at Vout 1 Put the jumper cap at JP5 2-3 to output 5VDC at Vout 1 Put the jumper cap at JP6 1-2 to output 12VDC at Vout 2 Put the jumper cap at JP6 2-3 to output 5VDC at Vout 2 18
20 Connecting the Reader Suprema Biometric Devices (BioLite Net) Red: 12V+ Black: GND Green: W-D0 White: W-D1 Black: W-GND Yellow (with Black stripe): C2- Blue (with white stripe): C2+ Note: Connect to NMINI2 Com2 Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND 19
21 Connecting the Reader Suprema Biometric Devices (BioEntry Plus) Red: 12V+ Black: GND Green: W-D0 White: W-D1 Black: W-GND Yellow: C2- Blue: C2+ Note: Connect to NMINI2 Com2 Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND 20
22 Connecting to Another Controller for Cross-board Interlock Purpose NMiNi2 (A) NMiNi2 (B) Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1+ C1 C2+ C2 Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1+ C1 C2+ C2 Vout1 Vout2 Buzzer RST COLD HRT MCU COMM1 COMM2 RS232 C1 RS232 C2 Vout1 Vout2 Buzzer RST COLD HRT MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 LED1 LED2 GND-ETH Relay 1 Relay 2 Addressing Dip Switch Selection Jumper GND-ETH Relay 1 Relay 2 Addressing Dip Switch Selection Jumper +12V GND EARTH CM1 CM2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND NC1 NO1 NC2 NO2 NC1 NO1 NC2 NO2 +12V GND EARTH CM1 CM2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Please configure the input type of specific point to Interlock using Platform1 Server Cross-board interlock only support up to two NMiNi2 21
23 Connecting to the PC via Network. NMiNi2-1 NMiNi2-2 NMiNi2-3 NMiNi2 - n CAT-5 Network Cable Network Switch EntryPass Platform1 Server Access Control System Factory default IP address for network controller is
24 Performing Cold Start For PCB ver. DRB-04-PCB DRB PCB Version DRB-04-PCB Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 Vout2 Reset Button Buzzer RST COLD HRT Cold Button MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 JP4 7-8 GND-ETH Relay 1 Relay 2 DRB-04-PCB ON Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Steps of performing cold start: 1. Please ensure that the jumper is inserted on JP Press and Hold COLD switch 3. Press RESET Switch and Release RESET switch 4. Release COLD switches when a beeping sound heard 5. Please remove the jumper cap after perform cold start NMiNi2 RDK will also perform COLD START after cold start the DRB Note: Cold Start will not reset the network parameter to default value 23
25 Performing Cold Start For PCB ver. DRB-05-PCB and above DRB PCB Version DRB-05-PCB and above Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 Vout2 Reset Button Buzzer RST COLD HRT Cold Button MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 JP4 1-2 GND-ETH Relay 1 Relay 2 DRB-05-PCB ON Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Steps of performing cold start: 1. Please ensure that the jumper is inserted on JP Press and Hold COLD switch 3. Press RESET Switch and Release RESET switch 4. Release COLD switches when a beeping sound heard 5. Please remove the jumper cap after perform cold start NMiNi2 RDK will also perform COLD START after cold start the DRB Note: Cold Start will not reset the network parameter to default value 24
26 Performing Factory Default For PCB ver. DRB-04-PCB DRB PCB Version DRB-04-PCB Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 Vout2 Reset Button Buzzer RST COLD HRT Cold Button MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 JP4 1-2 GND-ETH Relay 1 Relay 2 DRB-04-PCB ON Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Steps of performing Factory Default: 1. Please ensure that the jumper is inserted on JP Press and Hold COLD switch 3. Press RESET Switch and Release RESET switch 4. Release COLD switches when a beeping sound heard 5. Please remove the jumper cap after perform factory default NMiNi2 RDK network parameter will reset to default after factory default the DRB Default IP: Default Port: 2020 Default Server IP:
27 Performing Factory Default For PCB ver. DRB-05-PCB and above DRB PCB Version DRB-05-PCB and above Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 Vout2 Reset Button Buzzer RST COLD HRT Cold Button MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 JP4 7-8 GND-ETH Relay 1 Relay 2 DRB-05-PCB ON Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Steps of performing Factory Default: 1. Please ensure that the jumper is inserted on JP Press and Hold COLD switch 3. Press RESET Switch and Release RESET switch 4. Release COLD switches when a beeping sound heard 5. Please remove the jumper cap after perform factory default NMiNi2 RDK network parameter will reset to default after factory default the DRB Default IP: Default Port: 2020 Default Server IP:
28 Performing Communication Crypto Key Reset For PCB ver. DRB-04-PCB DRB PCB Version DRB-04-PCB Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 Vout2 Reset Button Buzzer LED1 LED2 RST COLD HRT Cold Button MCU COMM1 COMM2 JP4 5-6 RS232 C1 RS232 C2 GND-ETH Relay 1 Relay 2 DRB-04-PCB ON Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Steps of performing Crypto Key Reset: 1. Please ensure that the jumper is inserted on JP Press RESET Switch and Release RESET switch 3. Please remove the jumper after performing Crypto Key reset 27
29 Performing Communication Crypto Key Reset For PCB ver. DRB-05-PCB and above DRB PCB Version DRB-05-PCB and above Vout 1 GND Vout 2 RD0 1 RD1 1 GRN 1 RED 1 BZR 1 TMP 1 RD0 2 RD1 2 GRN 2 RED 2 BZR 2 TMP 2 C1+ C1 C2+ C2 Vout1 Vout2 Reset Button Buzzer LED1 LED2 RST COLD HRT Cold Button MCU COMM1 COMM2 JP4 3-4 RS232 C1 RS232 C2 GND-ETH Relay 1 Relay 2 DRB-05-PCB ON Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND Steps of performing Crypto Key Reset: 1. Please ensure that the jumper is inserted on JP Press RESET Switch and Release RESET switch 3. Please remove the jumper after performing Crypto Key reset 28
30 CAT 5 Network Cable Power Supply 12V+ GND PG BAT/BS/VS Complete Overview EP.MiNi Exit Reader MiNi as Reader NMiNi2 D1 D0 GND C+ C- 12V+ 12V+ GND 12V+ GND Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1+ C1 C2+ C2 ENTRYPASS Vout1 Vout2 Buzzer RST COLD HRT MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 GND-ETH Relay 1 Relay 2 Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND DRB Network Switch Break Glass Door Sensor and Push Button Key Switch + - EM Lock EntryPass Platform1 Server Access Control System 29
31 CAT 5 Network Cable Power Supply 12V+ GND PG BAT/BS/VS Complete Overview 3 rd Party Exit Reader Standard Wiegand Reader Tamper NMiNi2 Buzzer Red LED Green LED D1 D0 GND C+ C- 12V+ 12V+ GND 12V+ GND Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1+ C1 C2+ C2 ENTRYPASS Vout1 Vout2 Buzzer RST COLD HRT MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 GND-ETH Relay 1 Relay 2 Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND DRB Network Switch Break Glass Door Sensor and Push Button Key Switch + - EM Lock EntryPass Platform1 Server Access Control System 30
32 CAT 5 Network Cable Power Supply 12V+ GND PG BAT/BS/VS Complete Overview Suprema Exit Reader Suprema Biometric Reader NMiNi2 C- C+ C2- C2+ W-GND W-D1 W-D0 GND C+ C- 12V+ 12V+ GND 12V+ GND Vout1 GND Vout2 RD01 RD11 GRN1 RED1 BZR1 TMP1 RD02 RD12 GRN2 RED2 BZR2 TMP2 C1+ C1 C2+ C2 ENTRYPASS Vout1 Vout2 Buzzer RST COLD HRT MCU COMM1 COMM2 RS232 C1 RS232 C2 LED1 LED2 GND-ETH Relay 1 Relay 2 Addressing Dip Switch Selection Jumper +12V GND EARTH NC1 CM1 NO1 NC2 CM2 NO2 ACC BATT IN1 IN2 GND IN3 IN4 GND GND GND DRB Network Switch Break Glass Door Sensor and Push Button Key Switch + - EM Lock EntryPass Platform1 Server Access Control System 31
33 NMiNi 2 User Interface Company Name Display Time or Logo Previous Tab Menu Time Calendar Next Tab Menu Use the < or > key to access any Tab Menu (Quick Function, Time Attendance, Diagnostic) and press OK to access the Tab Menu 32
34 NMiNi 2 User Interface Press Menu to access Main Menu Default Password: Use the < or > key to choose the Menu Items and press OK to select 33
35 NMiNi 2 User Interface Use the < or > key to perform Up and Down, press OK to select, press Menu to back/exit 34
36 NMiNi 2 Tricolor LED Indication Tricolor LED Indicator LED Color LED Behavior Status Blue Blinking Idle/Sleep Mode Green Static Valid Action (e.g.: Valid Card Entry) Red Static Invalid Action (e.g.: Door Force Open) Red Blinking System Error (e.g.: No Physical Network Conn.) Please check the system error in Diagnostic Page if the unit s RED LED blinking 35
37 NMiNi 2 Main Menu Structure Map System Database Info Service Exit System Setting Door Setting Network Setting Date Setting Time Setting Command Quit Card Setting Quit RDK Version DRB Version Quit Card Number Card Binary Help Line Info Quit Digit System Inhibit Mode IP Address Reset Door Data Install Card Admin Pin Security Mode Subnet Mask Format Memory Delete Card Unit Address Site Code Gateway Factory Default View Card Standalone Door Pin Port Listen Reset AES Quick Install As Exit Reader Door Pin TZ Port Transmit Quit Quick Delete Delay 2 Function Exit Button TZ Server IP Reset Card Pin Quit Auto Release TZ Ethernet Speed Reset Lockout Release Time Quit Rst Lockout Time Open Time Total Card Pin Trials Quit Pin Reset Time Card + Pin TZ Key Card Pin TZ Tamper Pin Rst Interval Door Sensor Delay Lock Energize Use the < and > button on NMiNi2 Keypad to perform Up and Down selection Press OK on NMiNi2 keypad to select Press MENU on NMiNi2 Keypad to go back/exit User can also use number to make selection Quit 36
38 Factory Default IP Address Subnet Mask Gateway Server IP Connecting to EntryPass Platform1 Access Control System Before you begin to connect to the EntryPass Platform1 Access Control System, please make sure all the wiring connection is correct. On the NMINI 2 RDK, please make sure the following setting has been done: Advisable to perform factory default for the first time you turn on the power To configure the EP.NMINI 2 controller IP address To configure the EP.NMINI 2 controller subnet mask if required To configure the EP.NMINI 2 controller gateway if required To configure the EP.NMINI 2 controller Server IP to match the IP address of the Platform 1 Server 37
39 Cabling Information Communication Data Signal Max Distance Description NMiNi 2 to PC or Network Switch Network 100m (300 ft) 24 AWG, 4 Pairs (Cat 5e) NMiNi 2 to DRB 800m (2400 ft) 22 AWG, 2 Pairs, Shielded & Twisted Pair DRB to Reader Wiegand 30m (100 ft) 22 AWG, 2 Pairs, Shielded & Twisted Pair DRB to Electro-Magnetic Lock Power 30m (100 ft) 18 AWG, 1 Pair DRB to Push Button Contact 30m (100 ft) 22 AWG, 1 Pair DRB to Door Sensor Contact 30m (100 ft) 22 AWG, 1 Pair DRB to Other Controller for Cross-Board Interlock Contact 100m (300 ft) 22 AWG, 1 Pair 38
Wiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationModel: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:
Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect
More informationWiring Guide EP.HIO. Version 1.03 Last Updated:
Wiring Guide EP.HIO Version 1.03 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual Platform1 version 3 support 6 and 10
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationEX8. User Manual. Ver 1.0
EX8 User Manual Ver 1.0 EX8 manual ver1.0 Power supply important issue! Use separate power supply when ever is possible, one for EX8 and Reader and another for door lock. This way electrical isolation
More informationOperation manual For NG BIOSINGLE Version 1.1
Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationQuick Start Installation Guide
istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers
More informationSF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014
SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions
More informationLab 5: Access Control Training Station
Lab 5: Access Control Training Station Learning Objectives At the end of the lab, trainees should be able to: 1. Understand the functional block and hardware of an access control system. 2. Understand
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationCV-945 Stand-Alone Biometric Reader. Installation Instructions
CV-945 Stand-Alone Biometric Reader Installation Instructions Contents 1.0 Introduction... 03 2.0 Mounting... 03 3.0 Specifications... 04 4.0 Application Diagram... 04 5.0 Wiring... 05 6.0 Recommended
More informationACTpro 1500 Single Door IP Controller
ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500
More informationCanlan INSTALLATION MANUAL
Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationF7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions
F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More information1. Product Specification
1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationQuick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER
MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationContents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection
Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationGV-AS200 Controller. Hardware Installation Guide
GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationistar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More informationUser Manual. Split access control with intelligent secured power supply.
User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.
More informationInstallation Instructions (KF-2000)
VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809
More informationVANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD
VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start
More informationFingerprint Identification Proximity Reader. Quick Installation Guide
Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationInstruction Manual. Vogue. Security. Technology. Innovation 2013-V01
Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation
More informationB100-SA Standalone Biometric Reader
EN B100-SA Standalone Biometric Reader User Manual v.b1 Contents 1.0 INTRODUCTION 2.0 MOUNTING 3.0 SPECIFICATIONS......... 3 3 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED SWIPING TECHNIQUE...
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationOption X4 Additional Operator Panel AOP-2 Description of option Functional description
MULTI-LINE 2 DESCRIPTION OF OPTIONS Option X4 Additional Operator Panel AOP-2 Description of option Functional description DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615
More informationVIDI-AC-2CS Access Controller/ Reader
VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS
More informationBioPointe Reader Installation Guide
BioPointe Reader Installation Guide What s in this Guide Installation Steps 1 Key Parts of the BioPointe Reader 2 Cabling Requirements 3 Power Connection 3 PXL-500W Wiegand Controller Connection 3 Serial
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationUser Manual. Before using this device, read and follow all instructions for safety
User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All
More informationEZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL
EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More information5.5 AS Layout. GeoVision Technical Handbook 77
5.5 AS400 5.5.1 Layout GeoVision Technical Handbook 77 5.5.2 Wiegand Reader Connection AS400 supports up to eight Wiegand 26 ~ 64bit readers Wiegand connection has a distance limitation of 30m (~ 100ft)
More informationCM-500 SK 500 USER CODES KEYPAD
CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More informationInstallation Instructions
Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line
More informationSETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.
SETUP GUIDE INSTALLATION HANDBOOK For Integrators, Installers and Administrators Everything on how to get Kisi up and running getkisi.com 1 TABLE OF CONTENT 13 14 INSTALLING KISI AS A STAND-ALONE SYSTEM
More informationAR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud
More informationPXL-250 Tiger Controller
PXL-0 Tiger Controller This quick start guide is made up of specification sheets, a DO/DON T list, basic installation drawings, first time power-on instructions, and short descriptions of key terms and
More informationW3-H Waterproof Keypad/Reader/Controller
W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More informationUHF Reader Configuration Manual
UHF Reader Configuration Manual STA IR0207E STA IR0507E STA IR1207E STA 4R1207E Page 1 of 13 Reader Connections STA IR0207E, STA IR0507E, STA IR1207E STA 4R1207E Page 2 of 13 DB15 pin GPIO Connector diagram
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationImproX IXP20 Controller INSTALLATION MANUAL
MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
More informationQUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR-
QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series One Door TCP/IP Web Server Controller Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- Table of Contents 3 01- Introduction 4 02 - Overview 4 02.1
More informationQuick Installation Manual
Quick Installation Manual Please Note: Full Technical guide is located on the DVD if this is your first time installing a Hartmann Controls Access Control System. It is strongly recommended you review
More informationAmano Nexus Lite Controller INSTALLATION MANUAL
SPECIFICATIONS Working Environment Plastic Housing... Power NEXUS LITE Amano Nexus Lite Controller INSTALLATION MANUAL MODEL NUMBER: ISC920-0-0-AC-XX ISC921-5-0-AC-XX Designed to work in an indoor (dry)
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG Manual.qxp_Layout 0/0/06 :7 Page EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual.qxp_Layout 0/0/06 :7 Page System Components Proximity and Reader 0 x Proximity Tags x
More informationMegaTrak MCU-9000 Harness Wiring
MegaTrak MCU-9000 Harness Wiring Contents: 1. MCU9000 Connector Pin-Out Schematic 2. MCU9000 Connections when replacing an MCU3000 3. MCU9000 Connections Using 120VAC ( Hot ) Hook Switch (RS485 cable)
More informationSOFTWARE VERSION 3.10
738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationINSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3
INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4
More informationXpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.
Intelligent IP Access Control Reader Installation Guide EN 101.00.XPS2 V1.11 www.supremainc.com Important Safety Information Carefully review the information within the user manual before installing or
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More informationTIME SERVER NETSILON. Quick start.
TIME SERVER NETSILON Quick start This document refers to the following products: 907,900 NETSILON 7 (100-240 VAC) 907,901 NETSILON 7 (18-36 VDC) 907,902 NETSILON 7 (100-240 VAC + 18-36 VDC) www.bodet-time.com
More informationQUICK START GUIDE. 4G Lite Product Series
QUICK START GUIDE 4G Lite Product Series Table of Contents Section One: Overview 1 to 4 Section Two: Wiring 5 to 11 Section Three: Communication 12 to 15 Section Four: ACP or SDAC 16 to 17 Section Five:
More informationINNOMETRIKS INC. Rhino Quick Start Guide
INNOMETRIKS INC Rhino Quick Start Guide Rhino Quick Start Guide Innometriks Inc Fallbrook, Ca. 92028 Phone 760-207-6908 Sales: Sales@innometriksinc.com General Information: Info@innometriksinc.com Customer
More informationQUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint
More informationWiring Inside the card reader you will see a circuit board. The connections are as follows:
Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock
More informationVIS-3200 / VIS-3201 User Manual
2.4GHz Indoor Black Wireless Exit Button Receiver Keypad / Reader Access Control 500 Users Range of 50 Feet Delay and On/Off Toggle Mode Battery Operated Standalone No Software 1 VIS-3200 / VIS-3201 User
More informationBrivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ACS5000-E ENG-WI-001
Brivo Access Control System (ACS) Installation Manual DOCUMENT NUMBER ENG-DOC-003 ENG-WI-001 Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found
More informationINSTALLATION INSTRUCTIONS 920 EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount
More informationAccess Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64
Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)
More informationMULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD
MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS
More informationZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.
Box Content: - [System] - Inside Extensions - Decoder - Connector Cables - Power Supply Box Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully. Support Cat5e/6 Cable Or 4-Conductor Cable Quick
More informationCO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE
TABLE OF CONTENTS CO-485USB USB to CONVERTER TECHNICAL REFERENCE Specifications, Description and Technical Support... page 1 Connection Diagram... page 2 Set-Up & Testing... page 3 & 4 Power Supply Shunts...
More informationQuick Installation Guide
9292 Jeronimo Road Irvine, CA 92618-1905 Quick Installation Guide V2000 READER INTERFACE / ACCESS CONTROLLER 2006 HID Global Corporation. All rights reserved Document Version 1.6 October 5, 2006 Document
More informationFunction Menu. 1.Add/Delete. 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7.
Function Menu 1.Add/Delete 2.User Setting 1. Password 2. Access Mode 3. Extend Options 4. Single Floor 5. Multi Floors 6. Enroll FP 7. Delete FP 1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr 4.
More informationAtlas ATLAS INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS TECHNICAL FEATURES ATLAS: PIN IN/OUT / GENERAL VIEW
Atlas INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS 1 TECHNICAL FEATURES 2 : PIN IN/OUT / GENERAL VIEW 3 : IP ADDRESS CONFIGURATION 4 WARNINGS 5 SETTING TABLES 6 : CONNECTIONS EXAMPLES
More informationInstallation Guide. Avigilon ACM Embedded Controller
Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM
More informationW Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2
W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationINSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries
INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION
More informationMyostat Motion Control Inc Cool Muscle
Myostat Motion Control Inc Cool Muscle CM1ipx Manual Hardware and Software TCP/IP communication protocol Document Version 1.06 Myostat Motion Control Inc +1 905 836-4441 www.coolmuscle.com Table of Contents
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More information