Universal Communicator User Manual

Size: px
Start display at page:

Download "Universal Communicator User Manual"

Transcription

1 Revision B NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ BUYNKK ( ) FAX (480) <engineering@nkkswitches.com> All Rights Reserved Worldwide NKK Switches makes no warranty for the use of these products and assumes no responsibility for any errors, which may appear in this document, nor does it make a commitment to update the information contained herein. Smart Switch is trademark of NKK Switches. for B.doc Page 1 of 22

2 TABLE OF CONTENTS Table of Contents Purpose Applications Controller setup main window Single Picture Download window Switch Attributes window Batch Picture Download window Batch Attributes Download window Switch Data window Sending an image to controller (basic) Sending a manual command to controller (basic) Sending switch attributes to controller (basic) Sending a batch of images to controller (basic) Sending a batch of attributes to controller (basic)...22 for B.doc Page 2 of 22

3 1. Purpose This document is the user manual for 1.4. Both images and attributes can be downloaded. A PC computer with Widows XP, RS232 serial cable, and a comm port between 1 to16 set at is required Available image formats: LCD 36x24 1bit bitmaps. 254 bytes in size. LCD 64x32 1bit bitmaps. 318 bytes in size. OLED 64x48 switch. 24bit bitmap. 9,272 bytes in size. OLED 52x36 display. 64x48 24bit bitmap. 9,272 bytes in size. OLED rocker mono 96x64. 1bit bitmap. 830 bytes in size. 2. Applications Both the 64x32 and the 36x24 LCD s are best used to display simple text or icons representing the commands of the buttons with the colors representing status. The OLED 64x48 SmartSwitch or the OLED 52x36 display are best used for displaying slide shows of multiple images or a batch of images representing a video and adding attribute loops such as those shown below. Such image batches can be obtained through video editing programs such as QuickTime. The attributes and loops are explained in detail in the CL01 Intelligent Controller. The OLED rocker mono 96x64 is best for menus, scale settings or icons. for B.doc Page 3 of 22

4 Table 1, Two OLED 64x48 loops File Name DEC Address HEX Address SW1 SW2 EP1 T1V T2V ClownFish A ClownFish B ClownFish C ClownFish D ClownFish ClownFish ClownFish ClownFish Table 1 shows two loops. One starting at 007AH and ending at 0112H. The second one starts at 007BH and ends at 0113H. The loops run independently without interference between the two. For addresses 0112H and 0113H the 0000H in SW1 and SW2 columns tells the controller to go back to the starting address of the loop. 3. Controller setup 3.1. Controller shall be connected to computer via RS232 serial cable Logic Boards can be attached to Controller in several ways which depend on product. For all possible attachment ways J1 of Logic Board has to be attached to J1 of Controller with pin 1 matching to pin 1. Note: Attaching logic board to controller without matching pin 1 to pin 1 will cause damage Illustration 1 and 2 show two possible ways to attach Logic Boards to Controller Red line of ribbon cable shall be on pin 1 on each header. Illustration 1, Controller and logic board(s) for B.doc Page 4 of 22

5 Illustration 2, Controller and logic board without cable 4. main window Illustration 3, Main window interface This is main window of program Menu Items Single Pictures displays Single Picture Download window used for downloading a single image to controller Batch Pictures displays Batch Picture Download window used for downloading a batch of images to controller Switch Data displays Switch Data window used for inspecting the Switch Data in native format. for B.doc Page 5 of 22

6 Controller Feedback displays a Notepad with feedback from controller since program was started. Clears before first feedback About displays information about program Progress Reports Displays progress of downloading each image, progress of importing an image batch into program, elapsed time, unit time, and progress of downloading an image batch to controller Quit Button exits program. 5. Single Picture Download window Illustration 4, Single Picture Download window This window is used to download a single image, a group of attributes, or to download a command Full File Name select menu Selects image to send to controller Default image is Koala.bmp Import bmp option is used to import bmp files through a file retrieval dialog Displays full name and path of image file Determines information used and displayed depending on size of image file. for B.doc Page 6 of 22

7 5.2. Image Address text box Selects controller address for image to FFFF for OLED versions. 01 to FF for LCD versions Image display Displays short name of image file File Size display Displays file size in bytes of first image file Switch Type display Displays switch type Is dependent on image file size selected in Full File Name text box Picture box display Displays image selected in Full File Name text box Clear button Clears the Manual Command Input text box and Send to / Reply from Controller text box Manual Command Input text box User input of ASCII characters or HEX numbers to write commands for controller One character per nibble Send Manual Command button Sends all text from Manual Command Input text box to controller Spaces and carriage returns are ignored Download Text File button Sends Hex data from text file to controller File must start with RAW DATA for program to recognize it Data must be in Hex format Ignores spaces, line feed and carriage return characters Send to / Reply from Controller text box Check box enables display of transmitted image data. Default is set to disable for faster downloads. Manual command transmitted data are displayed Displays in Hex format Transmit in blue. Receive in black Edit Attributes button Displays Switch Attributes window On/Off image boxes Displays current colors selected for selected image Visible for LCD versions only Download Attributes button Downloads attributes to current address in Image Address text box Address Downloading display Displays current address that image is being downloaded to Comm Port select menu Selects comm port to send data to Available comm ports: 1, 2, Default is comm port 1. for B.doc Page 7 of 22

8 Note: When program is active currently selected comm port is open. Currently selected comm port will close when program is closed Comm Port Speed select menu Selects comm port speed Available speeds: 9600, and Comm State display Displays status of selected comm port Call button Sends command 01 to controller. Controller shall respond with a Query button Sends command to controller that responds with controller type, firmware version, and controller setting (switch type) Reset button Sends command 24 to controller. Controller shall reset Controller display Displays type of controller Firmware display Displays version of firmware on microchip Controller Setting display Displays controller setting (switch type). Note: Before downloading program compares Controller Setting to Switch Type display. If they are different a message box will appear to confirm download. Downloads can be continued or be canceled Controller check box Manually tells program that controller is present or not. Default checked L to R check box For OLED only. Image data is organized in left to right format for newer controllers or right to left format for older controllers. Default L to R Download Selected Image button Sends a command, address and selected bmp image data to selected address of controller Clear Current Address button Makes selected address all black Sends a command, address and blank data to selected address of controller Cancel Download button interrupts current download at end of image Close Form button Closes Single Picture Download window Does not end program. for B.doc Page 8 of 22

9 6. Switch Attributes window Illustration 5, Switch Attributes window for LCD 36x24 This window sets attributes for a single switch. Controls displayed vary depending on switch type selected. Note: For LCD 36x24 LED data will be sent with image data and not with other attributes Select a Color for On Cycle Each slider bar is one of three component colors; red, green, or blue. The mixed color is displayed to right of slider bars Select a Color for Off Cycle Each slider bar is one of three component colors; red, green, or blue. The mixed color is displayed to right of slider bars Image Address text box Selects controller address for image to FFFF for OLED versions. 01 to FF for LCD versions Pointer Module 1 text box (for 2 Switches only) Selects destination address when right button is pushed. Hex 00 to FF for LCD and 0000 to FFFF of OLED Pointer Module 2 text box (for 2 Switches only) Selects destination address when left button is pushed. Hex 00 to FF for LCD and 0000 to FFFF of OLED Pointer Timer 1 text box (for 2 Switches only) Selects destination address when timer 1 ends. Hex 00 to FF for LCD and 0000 to FFFF of OLED Pointer Timer 2 text box (for 2 Switches only) Selects destination address when timer 2 ends. Hex 00 to FF for LCD and 0000 to FFFF of OLED Timer 1 Value text box (for 2 Switches only) Selects millisecond length of timer 1. Hex 00 to FF. for B.doc Page 9 of 22

10 6.9. Timer 2 Value text box (for 2 Switches only) Selects millisecond length of timer 2. Hex 00 to FF Number of Switches select menu Chooses the number of switches the controller has; 2, 8, or 16 switches. The number of attributes downloaded will be adjusted by the number of switches selected. For 8 or 16 switches the text boxes are simply numbered Select button Preserves selected attributes for selected address and closes Switch Attributes window Cancel button Closes Switch Attributes window without preserving attribute information. 7. Batch Picture Download window Illustration 6, Batch Picture Download window This window is used to download a batch of images. for B.doc Page 10 of 22

11 7.1. Switch Type select menu Selects type of switch to be imported and downloaded Updates comm port speed to mach type of switch selected Import Batch button Opens a file dialog window from which user can select a file from a folder from which to import. Any file in a single folder can be selected. All files matching file size as determined by switch type will be imported from selected folder and displayed in Files and addresses list display Files are arranged in ASCII alphanumeric order Updates Batch Picture Download widow with information based on switch type and number of files Assigns an address for each image file imported Folder display Displays full name and path of image file First File display Displays first image file loaded File Size display Displays file size in bytes of first image file Edit Attributes button Displays Batch Attributes Download window Files and addresses list display Displays file titles and associated addresses for all files that were imported Files can be checked or unchecked to select them for download All button Checks all files None button Unchecks all files Invert button Checks all unchecked files. Unchecks all checked files Refresh button Refreshes Files and addresses list display and associated switch information when there are more than 100 files If there are more than 100 files imported Files and addresses list display and associated switch information are not updated until refresh button is pressed. Refresh button will turn red when a refresh is required Estimated Time Left, Elapsed, Unit displays the estimated time left, the estimated elapsed time, and estimated unit time per image. for B.doc Page 11 of 22

12 7.13. Offset Address text box Selects address in controller to send first image and offsets all other images Can take either hex address or decimal offset to FFFF for OLED. 01 to FF for LCD. Use +xxxxx for decimal offset for OLED. Use +xxx for decimal offset for LCD Max Offset display Displays maximum address that can be used for offsetting first image given number of image files loaded Offset button Updates files with selected start address or offset Reverse button Reverses address order. Highest to lowest and vice versa. Includes offset Start Address selection Selects address of first image to download. Includes offset and reverse order Stop Address selection Selects address of last image to download. Includes offset and reverse order and start address Start / Stop button Updates files by checking only files from selected start address through stop address. Removes all previous checked file arrangements Picture box display Displays image currently selected or downloading Address Downloading display Displays current address that image is being downloaded to Comm Port select menu Selects comm port to send data to Available comm ports: 1, 2, Comm Port Speed select menu Selects comm port speed Available speeds: 9600, 19200, and Comm State display Displays status of selected comm port Reset button Sends command 24 to controller. Controller shall reset Controller check box Manually tells program that controller is present or not. Default checked L to R check box For OLED only. Image data is organized in left to right format for newer controllers or right to left format for older controllers. Default L to R Send to / Reply from Controller text box Check box enables display of transmitted image data. Default is set to disable for faster downloads. Manual command transmitted data are displayed Displays in Hex format. for B.doc Page 12 of 22

13 Transmit in blue. Receive in black Clear button Clears the Send to / Reply from Controller text box Download Batch button Downloads checked files data to associated addresses to controller Will give visual feedback about state of download for each file Internal error checking captures controller s reply and looks for 6E errors then tracks failed files. user can reload failed files at end of download batch Download Selected Image button Downloads image data that is selected by user through Files and addresses list display Pause Download / Continue Download button Stops image data download at end of current image. Remembers current file that was being downloaded Continues image data download starting with file that was interrupted by pause button Cancel Download / Cancel Import button Cancels download batch or import batch at end of current image data download or file respectively Close Form button Closes Batch Picture Download window Does not end program. for B.doc Page 13 of 22

14 8. Batch Attributes Download window Illustration 7, Batch Attributes Download window This window is used to set attributes for batch of images. Note: For LCD 36x24 LED data will be sent with image data and not with other attributes Files, addresses and switch attributes display Displays image file name and address Displays switch attributes which can be edited by selecting the edit button Double clicking on the display allows selected image attributes to be edited using text boxes Number of Switches select menu Chooses the number of switches the controller has; 2, 8, or 16 switches. The number of attributes downloaded will be adjusted by the number of switches selected. For 8 or 16 switches the text boxes are simply numbered Only visible for LCD 36x24 LED or LCD 64x32 LED Edit Button Allows selected image attributes to be edited using text boxes Green Arrow sets value Red X cancels change Comm Port display Displays current comm port. for B.doc Page 14 of 22

15 8.5. Comm Port Speed display Displays comm port speed Comm State display Displays status of selected comm port Switch Type display Displays the type of switch Reset button Sends command 24 to controller. Controller shall reset Controller check box Manually tells program that controller is present or not. Default checked Send to / Reply from Controller text box Check box enables display of transmitted image data. Default is set to disable for faster downloads. Manual command transmitted data are displayed Displays in Hex format Transmit in blue. Receive in black Clear button Clears the Send to / Reply from Controller text box Address Downloading display Displays current address that image is being downloaded to Download Batch Attributes button Downloads attributes to controller Download Selected Image Attributes button Downloads image data to address from Files and addresses display Cancel Download button Cancels download Save Attributes button Saves attributes to predefined text file in current folder Close form button Requests to save attributes Exits back to Batch Picture Download window. for B.doc Page 15 of 22

16 9. Switch Data window Illustration 8, Switch Data window This window is used to observe the image data in the switches native format. It can load text files and other types of files that contain properly formatted image data Full File Name select menu Selects image to observe switch data Import bmp option is used to import bmp, text, and other files through a file retrieval dialog Displays full name and path of image file Determines information used and displayed depending on size and format of image file Image Address text box Selects controller address for image to FFFF for OLED versions. 01 to FF for LCD versions Image display. for B.doc Page 16 of 22

17 Displays short name of image file File Size display Displays file size in bytes of first image file Switch Type display Displays switch type Is dependent on image file size selected in Full File Name text box Picture box display Displays image selected in Full File Name text box Save Switch Data File button Saves switch data to a text file Download Switch Data button Sends a command, address and switch data to selected address of controller Cancel Download button interrupts current download at end of image Comm Port display Displays current comm port Comm Port Speed display Displays comm port speed Comm State display Displays status of selected comm port Address Downloading display Displays current address that image is being downloaded to Controller check box Manually tells program that controller is present or not. Default checked L to R check box For OLED only. Image data is organized in left to right format for newer controllers or right to left format for older controllers. Default L to R Send to / Reply from Controller text box Check box enables display of transmitted image data. Default is set to disable for faster downloads. Manual command transmitted data are displayed Displays in Hex format Transmit in blue. Receive in black Refresh button Re-retrieves switch data and displays it Clear button Clears the Send to / Reply from Controller text box Switch Data display Displays the switch data for the currently selected file. for B.doc Page 17 of 22

18 10. Sending an image to controller (basic) Illustration 9, Sending a single image for B.doc Page 18 of 22

19 11. Sending a manual command to controller (basic) Illustration 10, Sending a manual command for B.doc Page 19 of 22

20 12. Sending switch attributes to controller (basic) Note: For LCD 36x24 LED data will be sent with image data and not with other attributes. Illustration 11, Sending Switch Attributes for B.doc Page 20 of 22

21 13. Sending a batch of images to controller (basic) Illustration 12, Sending a Batch of Images for B.doc Page 21 of 22

22 14. Sending a batch of attributes to controller (basic) Note: For LCD 36x24 LED data will be sent with image data and not with other attributes. Illustration 13, Sending a Batch of Attributes for B.doc Page 22 of 22

IS-DEV KIT-9 User Manual

IS-DEV KIT-9 User Manual IS-DEV KIT-9 User Manual Revision C Firmware Version 1.0 NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail

More information

IS-Dev Kit-7 & 7D User s Manual

IS-Dev Kit-7 & 7D User s Manual IS-Dev Kit-7 (ISC15ANP4) IS-Dev Kit-7 & 7D User s Manual Revision A Firmware Version 2.4 IS-Dev Kit-7D (ISC01P) NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655)

More information

IS-Dev Kit-1 Users Manual

IS-Dev Kit-1 Users Manual IS-Dev Kit-1 Users Manual Revision A IS-Dev Kit-1 Version 1.1 NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail

More information

IS-Dev Kit-8 User Manual

IS-Dev Kit-8 User Manual IS-Dev Kit-8 User Manual Revision A IS-Dev Kit-8 Version 1.0 NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail

More information

IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual

IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual IS-Dev Kit-5 and IS-Dev Kit-6 Users Revision A IS-Dev Kit-5 and IS-Dev Kit-6 Version 1.2 NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942

More information

OLED Logic Boards Users Manual

OLED Logic Boards Users Manual Revision B NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail All Rights Reserved Worldwide

More information

IS-Dev Kit-6, 6D, 6C, 6HB User s Manual

IS-Dev Kit-6, 6D, 6C, 6HB User s Manual IS-Dev Kit-6, 6D, 6C, 6HB User s Manual Revision C IS-Dev Kit-6 (IS15EBFP4RGB) Firmware Version 1.3 IS-Dev Kit-6D (IS01EBFRGB) IS-Dev Kit-6C (IS15ESBFP4RGB) IS-Dev Kit-6HB (IS15EBFP4RGB- 09YN) NKK SWITCHES

More information

IS-Dev Kit-8 User Manual

IS-Dev Kit-8 User Manual IS-Dev Kit-8 User Manual Revision E Version 3.0 IS18WWC1W Development Kit. NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435

More information

OLED Engineering Kits User Manual

OLED Engineering Kits User Manual OLED Engineering Kits User Manual Revision C Firmware Version 1.X NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail

More information

IS-ENG-KIT Features Revision A

IS-ENG-KIT Features Revision A IS-ENG-KIT Features Revision A NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail All

More information

LCD 36x24 Logic Boards User Manual

LCD 36x24 Logic Boards User Manual LCD 36x24 Logic Boards User Manual Revision D NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail

More information

LCD 64x32 Logic Boards User Manual

LCD 64x32 Logic Boards User Manual LCD 64x32 Logic Boards User Manual Revision D NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail

More information

IS-CHPMP User Manual

IS-CHPMP User Manual IS-CHPMP User Manual Revision B NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435 e-mail All

More information

User s Guide. I 2 C Bus Serial EEPROM Programmer Software for MCC ASCII Interface I 2 C Bus Host Adapters.

User s Guide.  I 2 C Bus Serial EEPROM Programmer Software for MCC ASCII Interface I 2 C Bus Host Adapters. User s Guide I 2 C Bus Serial EEPROM Programmer Software for MCC ASCII Interface I 2 C Bus Host Adapters Version 2 10101000 I 2 C Bus 01001010 www.mcc-us.com Introduction The MCC iburner I 2 C Bus Serial

More information

IS-S0108 Single Switch Solution

IS-S0108 Single Switch Solution IS-S0108 Single Switch Solution IS-S0108 Single Switch Solution Revision D NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435

More information

Room Control Module (2000i-RCM) Interface Command Structure. for the

Room Control Module (2000i-RCM) Interface Command Structure. for the Room Control Module (2000i-RCM) Interface Command Structure for the 2000i-DVS Interactive Whiteboard 99-00544-00 Rev A0 FCC Warning This equipment has been tested and found to comply with the limits for

More information

ASIC-200 Version 5.0. integrated industrial control software. HMI Guide

ASIC-200 Version 5.0. integrated industrial control software. HMI Guide ASIC-200 Version 5.0 integrated industrial control software HMI Guide Revision Description Date C Name change, correct where applicable with document 4/07 HMI Guide: 139168(C) Published by: Pro-face 750

More information

CLCD1 Serial 1 wire RS232 LCD development board

CLCD1 Serial 1 wire RS232 LCD development board CLCD1 Serial 1 wire RS232 LCD development board Can be used with most 14 pin HD44780 based character LCD displays Use with 1,2,3 or 4 line displays. (Four line LCD shown above) Shown assembled with optional

More information

V G23 Rev: 12/04

V G23 Rev: 12/04 Software Manual HMI V230-21-G23 Rev: 12/04 No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or transmitted in any

More information

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks 45SD Series Bus Expansion Cards For use with Series Photoelectric Sensors on SDS Bus Networks Banner model 45SD plug-in bus cards enable a Banner Series sensor to establish a logical relationship between

More information

NEW CEIBO DEBUGGER. Menus and Commands

NEW CEIBO DEBUGGER. Menus and Commands NEW CEIBO DEBUGGER Menus and Commands Ceibo Debugger Menus and Commands D.1. Introduction CEIBO DEBUGGER is the latest software available from Ceibo and can be used with most of Ceibo emulators. You will

More information

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual FERGUSON BEAUREGARD RTU-5000 Configurator User Manual The Ferguson Beauregard RTU-5000 Configurator program and manuals are Copyright 1997-2004 by

More information

melabs Serial LCD Firmware Version 1.1 3/5/07

melabs Serial LCD Firmware Version 1.1 3/5/07 melabs Serial LCD Firmware Version 1.1 3/5/07 The melabs Serial LCD (SLCD) can display serial data from either asynchronous RS232-style or synchronous I 2 C input. A range of baud rates from 2400 to 57,600

More information

Boomerang System Administrator Manual

Boomerang System Administrator Manual Boomerang System Administrator Manual SG001-0003-01-B2.doc Page 1 of 43 Table of Contents INTRODUCTION...4 BOOMERANG CLIENT...5 FILE...6 3.1. Logout...... 6 3.2. Exit... 6 VIEW...7 4.1. Sensors events

More information

AMT203 ABSOLUTE ENCODER Demo Kit User Guide DISCONTINUED

AMT203 ABSOLUTE ENCODER Demo Kit User Guide DISCONTINUED AMT203 ABSOLUTE ENCODER Demo Kit User Guide PART NUMBER: AMT203 AMT-DMBD Demo Board DESCRIPTION: date 2 of 13 DEMO KIT USER GUIDE The AMT-DMBD Demo Board is designed for testing and configuring the AMT

More information

LCM-100 LCD Module User s Manual

LCM-100 LCD Module User s Manual LCM-100 LCD Module User s Manual Copyright This document is copyrighted, 2002, by Advantech Co, Ltd All rights are reserved Advantech Co, Ltd reserves the right to make improvements to the products described

More information

Camera control software GigaCam

Camera control software GigaCam Camera control software GigaCam Operation Manual Version 1.06 CONTENTS 1. Starting the software... 3 2. Discovery the Camera... 4 3. Open the Camera... 5 4. Image setting... 6 5. Acquisition start / stop...

More information

PLC Interface. Configuration and Operations Manual (Color OIT) Link Electric & Safety Control Company 444 McNally Drive Nashville, TN 37211

PLC Interface. Configuration and Operations Manual (Color OIT) Link Electric & Safety Control Company 444 McNally Drive Nashville, TN 37211 PLC Interface Configuration and Operations Manual (Color OIT) PH: (615) 833-4168 FAX: (615) 834-1984 Link Electric & Safety Control Company 444 McNally Drive Nashville, TN 37211 OmniLink 5000 Table of

More information

Rev. 1.5 (Preliminary)

Rev. 1.5 (Preliminary) Part No. Description Version 2.0 Documentation Rev. 1.5 (Preliminary) Vuolas Electronics Oy Ltd. Kunnansarka 2 FIN-37150 Nokia, Finland Tel. +358 (0)3 342 6900 Fax +358 (0)3 342 5800 e-mail: vuolas@vuolas.com

More information

GAMING MONITOR. OSD Sidekick

GAMING MONITOR. OSD Sidekick GAMING MONITOR OSD Sidekick Copyright OSD Sidekick Installation Guide 2018 GIGA-BYTE TECHNOLOGY CO., LTD. All rights reserved. The trademarks mentioned in this manual are legally registered to their respective

More information

Developer Information. Videohub. Includes Blackmagic Videohub Ethernet Protocol and Videohub RS-422 Protocol

Developer Information. Videohub. Includes Blackmagic Videohub Ethernet Protocol and Videohub RS-422 Protocol Developer Information Videohub Includes Blackmagic Videohub Ethernet Protocol and Videohub RS-422 Protocol May 2018 Contents Videohub Blackmagic Videohub Ethernet Protocol v2.3 3 Summary 3 Protocol Preamble

More information

SmartPick Service Interface Installation, Setup and Event Log Download, Windows 7 & 8

SmartPick Service Interface Installation, Setup and Event Log Download, Windows 7 & 8 Seite: 1/14 SmartPick Service Interface Installation, Setup and Event Log Download, Windows 7 & 8 1 Introduction 2 2 Flowchart 3 3 Installation 4 3.1 Installing the USB to Serial Adapter 4 3.2 Installing

More information

Swyx Skin Editor - User Documentation

Swyx Skin Editor - User Documentation Swyx Skin Editor - User Documentation Swyx Skin Editor - The Editor for creating individual skins As of: December 2009 2000-2009 Swyx. All rights reserved. Legal Information Whilst Swyx attempt to convey

More information

JNIOR. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Support Tool Manual. Release 6.0

JNIOR. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Support Tool Manual. Release 6.0 JNIOR A Network I/O Resource Utilizing the JAVA Platform Release 6.0 Supports JNIOR Series 3 and 4 JNIOR OS 3.4 or greater required INTEG Process Group, Inc. 2919 East Hardies Rd, First Floor Gibsonia,

More information

RC232 Configuration and Communication Tool (CCT) User Manual

RC232 Configuration and Communication Tool (CCT) User Manual RC232 Configuration and Communication Tool (CCT) User Manual Table of Contents TABLE OF CONTENTS... 1 INSTALLATION GUIDE... 2 SCREEN SETTINGS... 2 INTRODUCTION... 2 CONNECTING TO THE MODULE... 3 TERMINAL

More information

MultiSite Suite: General Ledger

MultiSite Suite: General Ledger MultiSite Suite: General Ledger User s Manual version 2.2.97 Copyright & Trademarks Copyright Notice and Trademarks 2003 by Brent Lawrence, LLC. All rights reserved. Reprinted and edited by MultiSite Systems,

More information

ISO INTERNATIONAL STANDARD. Hard-copy output of engineering drawings Specification for the structure of control files

ISO INTERNATIONAL STANDARD. Hard-copy output of engineering drawings Specification for the structure of control files INTERNATIONAL STANDARD ISO 14985 First edition 1999-07-01 Hard-copy output of engineering drawings Specification for the structure of control files Sortie papier de dessins d'engineering Spécifications

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick TOOLSTICK UNIVERSITY DAUGHTER CARD USER S GUIDE 1. Handling Recommendations To enable development, the ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent

More information

LE840/LE850. Printer Setting Tool Manual Technical Reference

LE840/LE850. Printer Setting Tool Manual Technical Reference LE840/LE850 Printer Setting Tool Manual Technical Reference Table of Contents 1. INTRODUCTION 1 SUPPORTED PRINTERS... 1 FEATURES... 1 OUTLINE OF THE FUNCTIONS... 2 NOTATION... 2 SCREENS USED IN THIS DOCUMENT...

More information

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A RS232 User Guide Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K 020-1344-00A Page 1 Copyright March 2018 by Leyard Optoelectronics Co., Ltd. and Planar Systems, Inc. All rights

More information

PM290 POWERMETER. Communication Protocols ASCII & Modbus Reference Guide

PM290 POWERMETER. Communication Protocols ASCII & Modbus Reference Guide PM290 POWERMETER Communication Protocols ASCII & Modbus Reference Guide PM290 Communication Protocols Communication protocol is a method of transferring information between different devices (i.e., the

More information

Administration. Training Guide. Infinite Visions Enterprise Edition phone toll free fax

Administration. Training Guide. Infinite Visions Enterprise Edition phone toll free fax Administration Training Guide Infinite Visions Enterprise Edition 406.252.4357 phone 1.800.247.1161 toll free 406.252.7705 fax www.csavisions.com Copyright 2005 2011 Windsor Management Group, LLC Revised:

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-401USB 4x1 USB Switcher. P/N: Rev 1

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-401USB 4x1 USB Switcher. P/N: Rev 1 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-401USB 4x1 USB Switcher P/N: 2900-300029 Rev 1 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Recycling Kramer Products

More information

Basic control panel. Features. Control panels 75

Basic control panel. Features. Control panels 75 Control panels 75 Basic control panel Features The basic control panel features: numeric control panel with an LCD display copy function parameters can be copied to the control panel memory for later transfer

More information

CEL MeshConnect ZICM35x Test Tool User Guide

CEL MeshConnect ZICM35x Test Tool User Guide User Guide 0011-00-17-02-000 CEL MeshConnect ZICM35x Test Tool User Guide CEL MeshConnect ZICM35x Test Tool User Guide Introduction CEL s MeshConnect EM357 Mini Modules combine high performance RF solutions

More information

PFC96Evo / PFC144Evo CONTROLLER MODBUS PROTOCOL

PFC96Evo / PFC144Evo CONTROLLER MODBUS PROTOCOL PFC96Evo / PFC144Evo CONTROLLER MODBUS PROTOCOL WARNING Installation, setting, inspection and maintenance operations must be performed only by qualified personnel in charge of it. Any operation must be

More information

Version N 2.0. LaurTec. RS232 Terminal. Debugging Embedded Systems. Author : Mauro Laurenti ID: PJ11004-EN. Copyright Mauro Laurenti 1/33

Version N 2.0. LaurTec. RS232 Terminal. Debugging Embedded Systems. Author : Mauro Laurenti ID: PJ11004-EN. Copyright Mauro Laurenti 1/33 Version N 2.0 LaurTec RS232 Terminal Debugging Embedded Systems Author : Mauro Laurenti ID: PJ11004-EN Copyright 2009-2017 Mauro Laurenti 1/33 License Copyright (C) 2009-2017 Author: Mauro Laurenti Web

More information

IDPort User Guide.

IDPort User Guide. IDPort User Guide www.monitorbm.com ID Port User Guide 2012 Monitor Business Machines Ltd. The software contains proprietary information of Monitor Business Machines Ltd. It is provided under a license

More information

JANUS EXPLORER. Janus Explorer Version 1.4 Quick Guide

JANUS EXPLORER. Janus Explorer Version 1.4 Quick Guide JANUS EXPLORER Version 1.4 Quick Guide Page 1 TABLE OF CONTENTS Introduction... 3 Installation... 3 Software Guide... 6 Send Commands... 8 Responses... 8 SMS and Dial... 8 Modem and SIM Details... 9 Phone

More information

Intel Architecture Segment:Offset Memory Addressing

Intel Architecture Segment:Offset Memory Addressing Name: Date: Lab Section: Lab partner s name: Lab PC Number: Objectives: Understanding video memory and character mapping of CGA characters in ROM BIOS, using the DOS debug command. Writing simple assembly-language

More information

SmartPick Service Interface Installation, Setup and Event Log Download, Windows XP

SmartPick Service Interface Installation, Setup and Event Log Download, Windows XP SmartPick Service Interface Installation, Setup and Event Log Download, Windows XP Seite: 1/15 1 Introduction 2 2 Flowchart 3 3 Installation 4 3.1 Installing the USB to Serial Adapter 4 3.2 Installing

More information

FM 4/100 USB Software for OSX

FM 4/100 USB Software for OSX FM 4/100 USB Software for OSX JLCooper makes no warranties, express or implied, regarding this software s fitness for a particular purpose, and in no event shall JLCooper Electronics be liable for incidental

More information

You have accessed an older version of a Paradyne product document.

You have accessed an older version of a Paradyne product document. You have accessed an older version of a Paradyne product document. Paradyne is no longer a subsidiary of AT&T. Any reference to AT&T Paradyne is amended to read Paradyne Corporation. Paradyne 6700-A2-GB41-10

More information

OP Handheld Manual. BALOGH 7699 Kensington Court Brighton, MI (248)

OP Handheld Manual. BALOGH 7699 Kensington Court Brighton, MI (248) OP Handheld Manual BALOGH 7699 Kensington Court Brighton, MI 48116-8561 (248) 486-7343 Notes are used to call attention to information that is significant to the understanding and operation of equipment.

More information

Cisco C880 M4 Server User Interface Operating Instructions for Servers with E v2 and E v3 CPUs

Cisco C880 M4 Server User Interface Operating Instructions for Servers with E v2 and E v3 CPUs Cisco C880 M4 Server User Interface Operating Instructions for Servers with E7-8800 v2 and E7-8800 v3 CPUs November, 2015 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT

More information

WELDSEQ Plus. Operation / Installation Manual. Weld Sequence PLC Terminal Program. Computer Weld Technology, Inc.

WELDSEQ Plus. Operation / Installation Manual. Weld Sequence PLC Terminal Program. Computer Weld Technology, Inc. Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com WELDSEQ Plus Weld Sequence PLC Terminal Program Operation

More information

NATIONAL CONTROL DEVICES Fusion ProXR Advanced Quick Start Guide

NATIONAL CONTROL DEVICES Fusion ProXR Advanced Quick Start Guide NATIONAL CONTROL DEVICES Fusion ProXR Advanced Quick Start Guide Fusion Relay Control Command Set N A T I O N A L C O N T R O L D E V I C E S ProXR Advanced Fusion Relay Control Command Set National Control

More information

hp l1619a smart attachment module

hp l1619a smart attachment module hp l1619a smart attachment module user s guide Smart Attachment Module 1 Notice This manual and any examples contained herein are provided as is and are subject to change without notice. Hewlett-Packard

More information

Specification. For. Serial Interface DN-T645/625

Specification. For. Serial Interface DN-T645/625 Date 2002-08-30 1 page of 55 Specification For Serial Interface DN-T645/625 Denon, Ltd. Date 2002-08-30 2 page of 55 Histories Rev. Date Name Description 1.00 Aug., 30, 02 J.Watanabe Date 2002-08-30 3

More information

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization Hall Research Technologies, Inc. Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization UMA1127 Rev B Copyright 2007. Hall Research Technologies, Inc. All rights 1163 Warner

More information

SRO100 Programmable Digital Indicator And Frequency Counter

SRO100 Programmable Digital Indicator And Frequency Counter USERS MANUAL SRO100 Programmable Digital Indicator And Frequency Counter Introduction The SRO100 Programmable Digital Indicator/ Frequency Counter may be used in any application requiring a programmable

More information

Lab 10 CST8214 Ian! D. Allen Fall 2007

Lab 10 CST8214 Ian! D. Allen Fall 2007 Name: Date: Lab Section: Lab partner s name: Lab PC Number: Objectives: Understanding video memory and character mapping of CGA characters in ROM BIOS, using the DOS debug command. Writing simple assembly

More information

Professional Jukebox Software

Professional Jukebox Software Professional Jukebox Software Exclusively distributed by Contents Security devices Page 3 The Load program Page 4 Music encryption Page 5 Splash screen Page 6 Main screen Page 7 Button Mode Page 8 Selecting

More information

N2KAnalyzer. User s Manual

N2KAnalyzer. User s Manual N2KAnalyzer NMEA 2000 Network Analysis Software User s Manual Revision 1.3.9 Copyright 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

Verifying a Restore Repository

Verifying a Restore Repository Verifying a Restore Repository As a part of the Laserfiche backup verification process, you may be asked to verify the contents of a Laserfiche restore repository. Once a month, an archival copy of the

More information

DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES

DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES NOTE: This application note is intended for users connecting an external device to a HomeVision serial port. It may be helpful to users connecting to

More information

Table of Contents Lesson 1: Introduction to the New Interface... 2 Lesson 2: Prepare to Work with Office

Table of Contents Lesson 1: Introduction to the New Interface... 2 Lesson 2: Prepare to Work with Office Table of Contents Lesson 1: Introduction to the New Interface... 2 Exercise 1: The New Elements... 3 Exercise 2: Use the Office Button and Quick Access Toolbar... 4 The Office Button... 4 The Quick Access

More information

Version User s Guide

Version User s Guide EN Sample Manager for MZ-X500/X300 Version 1.1.0 User s Guide Use this manual in combination with the User s Guide that comes with the Instrument. SAMPLEMANAMZX-110-E1A Contents Introduction... 3 What

More information

Littfinski DatenTechnik (LDT) Kleiner Ring 9 D Heist/Germany Phone: / Fax: /

Littfinski DatenTechnik (LDT) Kleiner Ring 9 D Heist/Germany Phone: / Fax: / Brief description: Command Codes for High Speed Interface-88-USB (HSI-88-USB) ( Firmware from version 0.71) (Software-version 1.2) The HSI-88-USB is an interface for the transmittance from the s88-feedback

More information

1602 SMART LCD DISPLAY MODULE HCMODU0122

1602 SMART LCD DISPLAY MODULE HCMODU0122 62 SMART LCD DISPLAY MODULE HCMODU22 Revision.. DISCLAIMER This document is provided "as is". Hobby Components Ltd makes no warranties, whether express, implied or statutory, including, but not limited

More information

Microsoft PowerPoint 2010 Beginning

Microsoft PowerPoint 2010 Beginning Microsoft PowerPoint 2010 Beginning PowerPoint Presentations on the Web... 2 Starting PowerPoint... 2 Opening a Presentation... 2 File Tab... 3 Quick Access Toolbar... 3 The Ribbon... 4 Keyboard Shortcuts...

More information

AMS COCKPIT USERS GUIDE. AMS Cockpit Version 1.1 USERS GUIDE

AMS COCKPIT USERS GUIDE. AMS Cockpit Version 1.1 USERS GUIDE AMS COCKPIT USERS GUIDE Table of Contents AMS Cockpit Version 1.1 USERS GUIDE Revision Date: 1/15/2010 A d v a n c e d M i c r o S y s t e m s, I n c. w w w. s t e p c o n t r o l. c o m i Table of Contents

More information

Rec Manager for EDIC-mini Tiny. User Manual

Rec Manager for EDIC-mini Tiny. User Manual Rec Manager for EDIC-mini Tiny User Manual Contents Contents...2 Overview...3 Glossary...3 What is Rec Manager Program...3 Main Program Features:...4 The Program Installation...5 Working With the Program...6

More information

KIMOTO K I M O S E T T E R R I P. Kimosetter RIP User Guide 1. Revised: February 2015 U SER GUID E (FOR W INDOWS 7 )

KIMOTO K I M O S E T T E R R I P. Kimosetter RIP User Guide 1. Revised: February 2015 U SER GUID E (FOR W INDOWS 7 ) KIMOTO K I M O S E T T E R R I P U SER GUID E (FOR W INDOWS 7 ) Revised: February 2015 Kimosetter RIP User Guide 1 COPYRIGHT AND TRADEMARKS Kimosetter RIP User Guide Copyright Notices for the Software

More information

NetMedia 2x16 Serial LCD Display Module V1.5

NetMedia 2x16 Serial LCD Display Module V1.5 NetMedia 2x16 Serial LCD Display Module V1.5 Table of Contents: Pinout... 2 Interfacing... 3 LCD Control Codes... 4 Creating Custom Characters... 6 BasicX-24 Example Program:... 7 2x16 Specifications...

More information

Océ DS10. Operator s manual

Océ DS10. Operator s manual Océ DS10 Operator s manual Océ-Technologies B.V. Trademarks Products in this manual are referred to by their trade names. In most, if not all cases, these designations are claimed as trademarks or registered

More information

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2 Chapter 5 Table of Contents Chapter 5: Communications 5 1 SR55 Communications Overview 5 2 Modbus Serial Communications Overview 5 2 Modbus TCP Network Communications Overview 5 2 EtherNet/IP Network Communications

More information

VSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later.

VSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later. VSM Manager Table of Contents Overview...1 Getting Started...1 Toolbar... 2 Serial Connection... 2 Refresh... 3 Help... 3 Tab Pages... 4 General... 4 Control...5 Schedule... 6 Command... 6 Communications...

More information

GANG Programmer for flash micro computers. User s Manual. TESSERA Technology INC. Third Edition September

GANG Programmer for flash micro computers. User s Manual. TESSERA Technology INC. Third Edition September GANG Programmer for flash micro computers User s Manual TESSERA Technology INC. Third Edition September 2008-1 - Table of Contents Chapter 1 Summary 3 1.1 System Configuration 4 Chapter 2 Installation

More information

Oracle Rdb Connectivity Manager Oracle Trace Player User Guide Release January 2019

Oracle Rdb Connectivity Manager Oracle Trace Player User Guide Release January 2019 Oracle Rdb Connectivity Manager Oracle Trace Player User Guide Release 7.3.4.0.0 January 2019 Oracle Rdb Connectivity Manager Oracle Trace Player User Guide, Release 7.3.4.0.0 Copyright 2015, 2019 Oracle

More information

Slicing. Slice multiple parts 13,0601,1489,1664(SP6P1)

Slicing. Slice multiple parts 13,0601,1489,1664(SP6P1) Slicing 13,0601,1489,1664(SP6P1) In this exercise, we will learn how to perform Slicing on multiple part. Slicing is the stage where the printing layers are set according to the printer definition or printing

More information

BIET EtherNet Interface

BIET EtherNet Interface BIET EtherNet Interface Preliminary Release Notes are used to call attention to information that is significant to the understanding and operation of equipment. This BALOGH manual is based on information

More information

[Notes] Provides important information on setting and using the printer command, if necessary.

[Notes] Provides important information on setting and using the printer command, if necessary. 2. COMMANDS 2. 1 Command Notation X X X X [Name] The name of the command. [Format] The code sequence. [Range] Gives the allowable ranges for the arguments. [Description] Describes the command s function.

More information

Protocol for downloading applications via CAN-bus into programmable terminals by MKT Systemtechnik

Protocol for downloading applications via CAN-bus into programmable terminals by MKT Systemtechnik Technical Information for 'programmable CAN-terminals without CANopen' Version 1.0 Protocol for downloading applications via CAN-bus into programmable terminals by MKT Systemtechnik to be used in CAN networks

More information

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL PAGE 1 OF 9 1. GENERAL The Avanti I²C Transducer Tester and PC-Interface (AVA-03) is a standalone device for accessing pressure/temperature transducers, which are equipped with a two-wire serial I²C interface.

More information

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3 PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000 User Manual Version 1.3 Promise Array Management Copyright 2003 Promise Technology, Inc. All Rights Reserved. Copyright by

More information

COMTool User Guide Version /02/2013

COMTool User Guide Version /02/2013 1 of 20 Contents Terms and Conditions of License for use of gratuitous software... 3 Purpose:... 3 Installation Instructions:... 4 Using COMTool:... 8 Select a COM Port... 8 Select a product... 8 Selecting

More information

Software Developer's Manual

Software Developer's Manual Software Developer's Manual Raster Command Reference QL-800/810W/820NWB Version 1.00 The Brother logo is a registered trademark of Brother Industries, Ltd. Brother is a registered trademark of Brother

More information

VarioAnalyze. User Manual. JENOPTIK Group.

VarioAnalyze. User Manual. JENOPTIK Group. VarioAnalyze User Manual JENOPTIK Group. Dear User Dear User You should carefully read these instructions before you start operating the VarioAnalyze Software. Editorial deadline: October 2005 Document

More information

RS-232 / TCP/IP Port Hardware. RS-232 / TCP/IP Port Hardware. TCP/IP Overview

RS-232 / TCP/IP Port Hardware. RS-232 / TCP/IP Port Hardware. TCP/IP Overview RS-232 / TCP/IP Port Hardware RS-232 / TCP/IP Port Hardware TCP/IP Overview The Serial and TCP/IP port share the same protocol. The TCP/IP connection is a very simple socket, sometimes referred to as Raw

More information

BASCOM51. Quick Start Guide

BASCOM51. Quick Start Guide BASCOM51 Quick Start Guide Date: 23 December, 2010 Document Revision: 1.01 BiPOM Electronics Telephone : 1-713-283-9970 E-mail : info@bipom.com Web : www.bipom.com 2010 by BiPOM Electronics. All rights

More information

BMP file format - Wikipedia

BMP file format - Wikipedia Page 1 of 3 Bitmap file header This block of bytes is at the start of the file and is used to identify the file. A typical application reads this block first to ensure that the file is actually a BMP file

More information

MCS 2 USB Software for OSX

MCS 2 USB Software for OSX for OSX JLCooper makes no warranties, express or implied, regarding this software s fitness for a particular purpose, and in no event shall JLCooper Electronics be liable for incidental or consequential

More information

CANopen Getting Started User's Manual

CANopen Getting Started User's Manual CANopen Getting Started User's Manual Version: 1.00 (October 2006) Model No.: MACOGETST-ENG All information contained in this manual is current as of its creation/publication. We reserve the right to change

More information

User Guide Laird Configuration and Test Utility Software. Version 1.0

User Guide Laird Configuration and Test Utility Software. Version 1.0 A Version 1.0 REVISION HISTORY Version Date Notes Approver 1.0 07 Dec 2016 Initial Release N. Zach Hogya 2 CONTENTS DVK Software Installation... 4 PC Settings Tab... 4 Port 1/Port 2 Options... 5 Options...

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions Frequently Asked Questions for Cisco Unified Personal Communicator 8.6 and Voice and Video Firmware 8.6 for Cisco Virtualization Experience Client 6215 FAQs 2 Basics 3 Setup

More information

Introduction Page 1. Power Supply Requirements & Hardware Options Page 2. External Connectors (Functions & Pinouts) Page 2

Introduction Page 1. Power Supply Requirements & Hardware Options Page 2. External Connectors (Functions & Pinouts) Page 2 A262B Interface Board Connection and Application Data Introduction Page 1 Power Supply Requirements & Hardware Options Page 2 External Connectors (Functions & Pinouts) Page 2 Software Requirements (Control

More information

D-ILA PROJECTOR RS-232C CONTROL SPECIFICATIONS. Victor Company of Japan, Limited. * D-ILA is a trademark of Victor Company of Japan, Limited.

D-ILA PROJECTOR RS-232C CONTROL SPECIFICATIONS. Victor Company of Japan, Limited. * D-ILA is a trademark of Victor Company of Japan, Limited. D-ILA TM PROJECTOR DLA-G3010series DLA-M2000series RS-232C CONTROL SPECIFICATIONS Victor Company of Japan, Limited * D-ILA is a trademark of Victor Company of Japan, Limited. Document Number CTGKE-0013

More information

UM PCSerial. Document information. PCSerial, MFRD52x development board, MFRC52x, PN51x design-in kit

UM PCSerial. Document information. PCSerial, MFRD52x development board, MFRC52x, PN51x design-in kit UM 119221 Rev. 2.1 07 July 2007 User manual Document information Info Keywords Abstract Content, MFRD52x development board, MFRC52x, PN51x design-in kit This document describes the demo program. The demo

More information

LCD03 - I2C/Serial LCD Technical Documentation

LCD03 - I2C/Serial LCD Technical Documentation LCD03 - I2C/Serial LCD Technical Documentation Pagina 1 di 5 Overview The I2C and serial display driver provides easy operation of a standard 20*4 LCD Text display. It requires only a 5v power supply and

More information